HomeMy WebLinkAboutP_Plans_20250106_v1.pdfABV ABOVE
AC AIR CONDITIONING
ACC ACCESS
ACT ACOUSTICAL TILE
ADA AMERICANS WITH DISABILITIES ACT
ADJ ADJACENT
AFF ABOVE FINISHED FLOOR
AL ALUMINUM
ALT ALTERNATE
ANB ANCHOR BOLT
ANC ANCHOR, ANCHORAGE
ANOD ANODIZED
APPROX APPROXIMATE
ARCH ARCHITECT, ARCHITECTURAL
ASF ALUMINUM STOREFRONT
AUTO AUTOMATIC
BD BOARD
BEL BELOW
BET BETWEEN
BLDG BUILDING
BLKG BLOCKING
BM BENCH MARK
BOH BACK OF HOUSE
B.O. OR B/BOTTOM OF
BTM BOTTOM
C/W COMPLETE WITH
CB CATCH BASIN
CG CORNER GUARD
CJ CONTROL JOINT
CLG CEILING
CLR CLEAR, CLEARANCE
CMU CONCRETE MASONRY UNIT
COL COLUMN
CONC CONCRETE
CONT CONTINUOUS OR CONTINUE
CP COOLER PANEL
CX CONNECTION
DA DOUBLE-ACTING
DEMO DEMOLISH, DEMOLITION
DETL DETAIL
(E)EXISTING
EA EACH
ELEC ELECTRIC, ELECTRICAL
EQ EQUAL
EQPM EQUIPMENT
E/W EACH WAY
EXTR EXTERIOR
FA FIRE ALARM
FCIC FURNISHED BY CONTRACTOR, INSTALLED
BY CONTRACTOR
FD FLOOR DRAIN
FE FIRE EXTINGUISHER
FEC FIRE EXTINGUISHER CABINET
FF FINISH FLOOR
FFE FINISHED FLOOR ELEVATION
FFL FINISHED FLOOR LINE
FIN FINISH, FINISHED
FCO FLOOR CLEANOUT
FOC FACE OF CONCRETE
FOF FACE OF FINISH
FOM FACE OF MASONRY
FOIC FURNISHED BY OWNER, INSTALLED BY
CONTRACTOR
FOIO FURNISHED BY OWNER, INSTALLED BY
OWNER
FRP FIBERGLASS REINFORCED PANEL
FTG FOOTING
GA GAUGE, GAGE
GALV GALVANIZED
GC GENERAL CONTRACTOR, CONTRACTOR
GI GALVANIZED IRON
GWB GYPSUM WALL BOARD
GYP GYPSUM
HB HOSE BIB
HDR HEADER
HM HOLLOW METAL
HT HEIGHT
HVAC HEATING/VENTILATING/AIR COND.
ID INSIDE DIAMETER
IE INVERT ELEVATION
INS INSULATE, INSULATED, INSULATION
INTR INTERIOR
L LENGTH
LAV LAVATORY
LVR LOUVER
LW LIGHTWEIGHT
MAS MASONRY
MAT'L MATERIAL, MATERIALS
MAX MAXIMUM
MDF MEDIUM DENSITY FIBERBOARD
MECH MECHANIC, MECHANICAL
M/E/P MECH/ELECT/PLUMBING
MFR MANUFACTURE, MANUFACTURER
MIN MINIMUM
MISC MISCELLANEOUS
MTL METAL
MW MILLWORK
N NORTH
(N)NEW
NIC NOT IN CONTRACT
NTS.NOT TO SCALE
O/OVER
OA OVERALL
OC ON CENTER, ON CENTERS
OD OVERFLOW DRAIN
OH OVERHEAD
OPP OPPOSITE
OSB ORIENTED STRAND BOARD
PCF POUNDS PER CUBIC FOOT
PERF PERFORATE, PERFORATED
PLF POUNDS PER LINEAL FOOT
PLAM PLASTIC LAMINATE
PLCS PLACES
PLY PLYWOOD
PNL PANEL
PSF POUNDS PER SQUARE FOOT
PSI POUNDS PER SQUARE INCH
PT PRESSURE TREATED
PTN PARTITION
QT QUARRY TILE
RD ROOF DRAIN
REF REFERENCE OR REFER
REFG REFRIGERATION
REIN.REINFORCING, REINFORCED
REV REVERSE (SIDE)
RO ROUGH OPENING
RWL RAINWATER LEADER
S SOUTH
SCH SCHEDULE
SCWD SOLID CORE WOOD
SD STORM DRAIN
SF SQUARE FOOT
SIM SIMILAR
SPEC SPECIFICATION(S)
SQ SQUARE
SSTL STAINLESS STEEL
STD STANDARD
STL STEEL
STRUCT STRUCTURAL
T&G TONGUE AND GROOVE
TBD TO BE DETERMINED
TEL TELEPHONE
TI TENANT IMPROVEMENT
T.O. OR T/TOP OF
TYP TYPICAL
UNO UNLESS NOTED OTHERWISE
VAR VARIES
VB VAPOR BARRIER
VERT VERTICAL
VG VERTICAL GRAIN
VIN VINYL
VTR VENT THROUGH ROOF
W WEST
WD WOOD
W/O WITHOUT
WWF WELDED WIRE FABRIC
W/WITH
A. CONTRACTOR TO VISIT THE SITE TO VERIFY AND BECOME FAMILIAR WITH ALL EXISTING
CONDITIONS PRIOR TO THE COMMENCEMENT OF WORK. IF CONFLICTS OCCUR, NOTIFY
THE ARCHITECT IMMEDIATELY. COMMENCEMENT OF WORK IN ANY GIVEN AREA SHALL BE
UNDERSTOOD TO REPRESENT THAT THE CONTRACTOR HAS CHECKED EXISTING
CONDITIONS AND FOUND THEM SATISFACTORY TO ACCEPT HIS PORTION OF THE WORK.
B. THE GENERAL CONTRACTOR SHALL FIELD VERIFY ALL MEASUREMENTS, LOCATIONS, AND
CHARACTERISTICS OF ALL WORK AND EQUIPMENT AND COORDINATE WITH THE
MANUFACTURER PRIOR TO THE START OF RELATED WORK. ANY VARIATIONS FROM
INDICATED DIMENSIONS OR CONDITIONS SHALL BE BROUGHT TO THE IMMEDIATE
ATTENTION OF THE ARCHITECT. WORK IN THE PROBLEM AREA SHALL NOT PROCEED UNTIL
APPROVED BY THE ARCHITECT AND OWNER.
C. CONTRACTOR SHALL INFORM ARCHITECT IN WRITING OF ANY AND ALL CONSTRUCTION
DISCREPANCIES. ERRORS AND OMISIONS ON THE CONSTRUCTION DOCUMENTS SHALL BE
BROUGHT TO THE ARCHITECT'S ATTENTION PRIOR TO PROCEEDING WITH WORK
AFFECTED BY SUCH DISCREPANCIES.
D. NO CHANGES SHALL BE MADE WITHOUT THE APPROVAL OF THE OWNER AND/OR
ARCHITECT.
E. THE GENERAL CONTRACTOR SHALL COORDINATE AND SCHEDULE ALL WORK WITH THE
PROPERTY MANAGER.
F. ALL CONSTRUCTION SHALL BE DONE IN ACCORDANCE WITH ALL APPLICABLE BUILDING
CODES.
G. PROVIDE FIRE-TREATED BLOCKING, BRACING, AND/OR STRUCTURE AS REQUIRED TO
FACILITATE INSTALLATION OF ALL WALL MOUNTED EQUIPMENT. GENERAL CONTRACTOR IS
RESPONSIBLE FOR DETERMINING THE SUPPORT REQUIRED TO MAINTAIN THE INTEGRITY
OF THE WALL AND SECURITY OF THE EQUIPMENT.
H. GENERAL CONTRACTOR IS TO ENSURE THAT RATED WALLS AND ANY PENETRATIONS
THROUGH RATED WALLS ARE CONSTRUCTED PER DETAILS AND IN ACCORDANCE WITH
LOCAL, MUNICIPAL, STATE, AND REFERRAL CODES. ALL DOORS IN RATED WALLS SHALL BE
PROPERLY RATED AND HAVE APPROPRIATE HARDWARE AND CLOSER AS INDICATED ON
PLANS AND IN SCHEDULE.
I. DO NOT SCALE DIMENSIONS. CALCULATE REQUIRED DIMENSIONS. WHERE THERE ARE
DISCREPANCIES OR MISSING DIMENSIONAL INFORMATION CONTACT ARCHITECT
IMMEDIATELY IN WRITING.
J. THE CONTRACTOR SHALL BE RESPONSIBLE FOR ESTABLISHING AND MAINTAINING
PROJECT SAFETY DURING THE CONSTRUCTION PROCESS TO PROTECT PERSONNEL,
TENANTS, AND BUILDING OCCUPANTS. REQUIREMENTS INCLUDE, BUT SHALL NOT BE
LIMITED TO O.S.H.A. PART 1926, LATEST EDITION IN FORCE.
K. G.C. TO PROVIDE DUMPSTER AT LOCATION APPROVED BY OWNER AND LOCAL
AUTHORITIES. CONSTRUCTION DEBRIS TO BE REMOVED FROM JOBSITE AND PUT IN
DUMPSTER DAILY.
L.G.C. TO KEEP A COMPLETE AND CLEAR RECORD OF ALL DEVIATIONS FROM THIS SET OF
DRAWINGS. DRAWING MARKUPS SHALL BE PROVIDED TO OWNER AND ARCHITECT AT
COMPLETION OF PROJECT.
PROJECT LOCATION
PROJECT LOCATION
PROJECT SITE
ALL DIMENSIONS AND CONDITIONS MUST BE CHECKED AND VERIFIED ON SITE BY THE
CONTRACTOR AND SUB-CONTRACTORS. THE PROJECT
MANAGER SHALL BE NOTIFIED IN WRITING OF ANY DISCREPANCIES
PRIOR TO PROCEEDING WITH THE WORK.
Sheet Title:
Designer:
Consultant:
Project Manager:
Reviewed By:
Approved By:
Project No:
Drawn By:
VICINITY MAP PROJECT CODE AND SCOPE SHEET INDEX
SITE MAP PROJECT DIRECTORY
GENERAL NOTESABBREVIATIONS
Project Title & Address:
Seal:
City Approval:
LOCATION PLAN
11
/
1
5
/
2
0
2
4
1
:
3
7
:
1
9
P
M
G001
COVER
281_P467002
INTERIOR REMODEL
601 MONSTER ROAD SW, RENTON, WA 98057
Designer
DH
BS
BC
281_P-467002
BS
281_P467002
601 MONSTER ROAD SW, RENTON, WA
98057
OWNER
CUMMING MANAGEMENT GROUP
1325 4TH AVE SUITE 1010
SEATTLE, WA 98101
CONTACT: SAM HANSEN
206.876.8008
ARCHITECT
CUSHING TERRELL
1201 WESTERN AVENUE, STE 700
SEATTLE, WA 98101
CONTACT: DAVID HO
206.282.6222
STURCTURAL ENGINEER
CUSHING TERRELL
1201 WESTERN AVE SUITE 700
SEATTLE, WA 98101
CONTACT: ASRADE MENGSTU
206.282.6222
GENERAL
G001 COVER
G101 CODE PLAN
Description: No: By: Date:
CODE SUMMARY
APPLICABLE CODES
2021 INTERNATIONAL BUILDING CODE (IBC) WITH WA STATE AND REDMOND AMENDMENTS
2021 INTERNATIONAL EXISTING BUILDING CODE (IEBC) WITH WA STATE AND REDMOND
AMENDMENTS
2021 INTERNATIONAL MECHANICAL CODE (IMC) WITH WA STATE AND REDMOND AMENDMENTS
2021INTERNATIONAL FUEL GAS CODE (IFGC) WITH WA STATE AND REDMOND AMENDMENTS
2021INTERNATIONAL FIRE CODE (IFC) WITH WA STATE AND REDMOND AMENDMENTS
2021UNIFORM PLUMBING CODE (UPC) WITH WA STATE AND REDMOND AMENDMENTS
2021INTERNATIONAL ENERGY CONSERVATION CODE WITH WA STATE AND REDMOND
AMENDMENTS
2023 NATIONAL ELECTRIC CODE (NEC) WITH WA STATE AND REDMOND AMENDMENTS
2009 ACCESSIBLE & USABLE BUILDINGS & FACILITIES (ICC/ANSIA117.1)
RENTON LOCAL AMENDMENTS AND REGULATIONS
OCCUPANCY CLASSIFICATION: F-1 & B
FIRE SPRINKLER SYSTEM: FULLY SPRINKLERED - NOT CHANGED
CONSTRUCTION TYPE: IB
CODE REVIEW (AREA OF WORK)
OCCUPANCY GROUP: F-2 (NO CHANGE)
CONSTRUCTION TYPE: 1B (NO CHANGE)
FULLY SPRINKLERED: YES (NO CHANGE)
BUILDING AREA: 167,443 GSF (NO CHANGE)
BUILDING HEIGHT: 1 STORY (NO CHANGE)
OCCUPANT LOAD: EXISTING & UNCHANGED
NUMBER OF EXITS: EXISTING & UNCHANGED
EXIT WIDTH: EXISTING & UNCHANGED
COMMON PATH OF TRAVEL: EXISTING & UNCHANGED
MAXIMUM PATH OF TRAVEL: EXISTING & UNCHANGED
SCOPE OF WORK
INSTALLATION AND ANCHORAGE OF A NEW OPEX MAIL SORTER MACHINE.
-NO CHANGE OF USE/OCCUPANCY
-NO CHANGE TO BUILDING ENVELOPE
AREA OF WORK: APPROX. 750SF
POR OF NW 1/4 & OF GOV LOT 1 IN SECTION 24-23-04 & THE SW 1/4 & GOV LOT 6 IN SECTION
13-23-04 DAF - BEG THE QUARTER CORNER BETWEEN SECTIONS 13 & 24 TH N 87-26-48 W 1214 FT
TO WLY MGN OF CO RD NO 8 CHARLES MONSTER RD SW & NOW KNOWN AS STEEL HILL ROAD TH
S 32-29-51 E 85.34 FT TH ON CURVE TO RGT RAD OF 256.48 FT DISTANCE OF 139.14 FT TO TPOB TH
S 01-24-51 E 268 FT TH S 88-35-09 W 436.55 FT TH S 02-33-12 W 115.03 FT TH S 70-05-34 W 95.47 FT
TH S 88-37-17 W 105.38 FT TH N 01-21-04 W 689.06 FT TH N 88-03-18 E 115.01 FT TH N 01-21-14 W
189.69 FT TO NON-RADIAL CURVE TO RIGHT RADIAL LINE BEARING S 08-52-39 W TH ALONG SAID
CURVE BEING SLY MARGIN OF S 143RD ST AS CONVEYED TO CITY OF RENTON UNDER
RECORDING NO 8702100643 TH ALONG SAID CURVE TO RIGHT RADIUS OF 524.90 FT AND ALONG
SLY MARGIN 94.61 FT TH S 70-45-53 E 147.08 FT TH ON CURVE TO RIGHT RADIUS 842.73 FT &
ALONG SOUTHERLY MARGIN 81.56 FEET TH S 65-13-10 E 257.10 FT TO WLY MARGIN OF 72ND AVE
SW TH ON CURVE TO RIGHT RADIUS OF 45 FT & ALONG SAID WESTERLY MARGIN 70.69 FEET TH S
24-46-50 W 24.57 FT TH ON CURVE TO LEFT RADIUS OF 180 FT AND ALONG SAID WESTERLY
MARGIN 82.35 FEET TH S 01-05-23 E 81.81 FT TO POB LESS ANY PORTION LY ELY OF C/L OF
CHARLES MONSTER ROAD VACATED BY CITY OF RENTON ORDINANCE NO 4123 RECORDING NO
8803070674 PARCEL B-1 OF CITY OF RENTON LOT LINE ADJUSTMENT NO LUA 98-148 LLA
RECORDING NO 9812309028 LESS ST PER REC #20211001001541 & 20211001001556
PARCEL NUMBERS
242304-9008
TYPE: C
Q-S-T-R: NW-24-23-4
ZONING INFORMATION
ZONE: IM
BUILDING USE: (F) FACTORY & INDUSTRIAL - UNCHANGED
NORTH REF
STRUCTURAL
S101 FOUNDATION PLAN
S102 EQUIPMENT PLAN
LEGAL DESCRIPTION
NORTH REF
EMEARSA
T
O
ISH
NG
N
NE RED
NRE
E
E IG
WOFE
TAT
A
TS
IO
G
N
I
S
S
O
EFS
ER
46161
L
A
R
P
D
G
N
S
U
T
RECEIVED
01/06/2025 striplett
BUILDING DIVISION
B2
5
0
0
0
0
6
2
_
V
1
REVIEWED
Rick Lee 01/08/2025
BUILDING DIVISION
THIS SET OF REVIEWED PLANS MUST BE MADE
AVAILABLE ON THE JOB AT ALL TIMES DURING
CONSTRUCTION.
Note: This review is for the non-structural review only
APPROVED
BUILDING DIVISION
THIS SET OF APPROVED PLANS MUST BE ON THE JOB AT ALL
TIMES DURING CONSTRUCTION. THIS BUILDING IS NOT TO BE
OCCUPIED UNTIL AFTER FINAL INSPECTION BY THE RENTON
BUILDING DIVISION AND RECEIPT OF CERTIFICATE OF
OCCUPANCY.
APPROVAL SHALL NOT BE CONSTRUED AS THE AUTHORITY TO
VIOLATE OR CANCEL ANY PROVISIONS OF CODES, ORDINANCES,
OR OTHER REGULATIONS ENFORCED BY THIS CITY.
DATE: 02/07/2025
DN
CR CR
UP
GIN1192
E
192E
GIN1192
E
192E
SSL
SSL
SSL
SSL
UBM
4
8
UBM
4
8
UBM48
UBM48
SSL
SSL
SSL
SSL
SSL
SSL
SSL
SSL
SSL
SSL
SSLSSL
SSL
SSL
3648
3648
484
8
4
8
4
8
3648
36483648
3648
3648
484
8
4
8
4
8
3648
36483648
364
8
3648
4848
3648
364
8
364
8
4848
364
8
3648
4848
3648
364
8
364
8
4848
4848
4848
484
8
484
8
364
8
364
8
4848 4848
364
8
364
8
364
8
364
8
364
8
4848 4848
364
8
364
8
364
8
364
8
364
8
4848 4848
364
8
364
8
364
8
364
8
364
8
4848 4848
364
8
364
8
364
8
486
4
4864 4864
486
4
2
4
6
4
486
4
246
4
48644864
246
4
246
4
AAAA
AA
A
A
AA AAAA
AAAA
AA
A
A
AA AAAA
AA
AA
AA
AA
AA
AA
AA
AA
AA
AA
AA
AA
AA
AA
AA
AA
AA
AA
AA
AA
AA AA
AA
AA
AA
AA
AA
AA AA
AA
AA
AA
AA
AA
AA AA
AA
AA
AA
AA
AA
AA AA
AA
AA
AA
MM
MM MM
MM
T
T
MM
TT
MMMM
TT
TT
8888 SF
8888
XXX/XX
EXIT PATH
SPACE AREA
OCCUPANCY TAG:
OCCUPANT LOAD FACTOR
NUMBER OF OCCUPANTS
CODE PLAN LEGEND
OVERALL DIAGONAL
MINIMUM EXIT SEPARATION
BUSINESS
150 GROSS
ASSEMBLY
15 GROSS
MECH, ELEC, STORAGE
300 GROSS
WAREHOUSE
500 GROSS
GOVERNING CODES:2021 INTERNATIONAL BUILDING CODE (IBC) WITH WA STATE AND REDMOND AMENDMENTS
2021 INTERNATIONAL EXISTING BUILDING CODE (IEBC) WITH WA STATE AND REDMOND
AMENDMENTS
2021 INTERNATIONAL MECHANICAL CODE (IMC) WITH WA STATE AND REDMOND
AMENDMENTS
2021 INTERNATIONAL FUEL GAS CODE (IFGC) WITH WA STATE AND REDMOND AMENDMENTS
2021 INTERNATIONAL FIRE CODE (IFC) WITH WA STATE AND REDMOND AMENDMENTS
2021 UNIFORM PLUMBING CODE (UPC) WITH WA STATE AND REDMOND AMENDMENTS
2021 INTERNATIONAL ENERGY CONSERVATION CODE WITH WA STATE AND REDMOND
AMENDMENTS
2023 NATIONAL ELECTRIC CODE (NEC) WITH WA STATE AND REDMOND AMENDMENTS
2009 ACCESSIBLE & USABLE BUILDINGS & FACILITIES (ICC/ANSIA117.1)
RENTON LOCAL AMENDMENTS AND REGULATIONS
OCCUPANCY CLASSIFICATION: F-1 & B
FIRE SPRINKLER SYSTEM: FULLY SPRINKLERED -NOT CHANGED
CONSTRUCTION TYPE: IB
BASIC ALLOWABLE HEIGHT AND AREA FROM TABLE 503
ALLOWABLE HEIGHT: 12 STORIES
ALLOWABLE AREA: UL
TOTAL GROSS BUILDING AREA = 167,443 SF
FIRST FLOOR = 90,041 SF
INCIDENTAL ACCESSORY OCCUPANCIES FROM TABLE 508.2.5
FURNACE ROOM WHERE ANY PIECE OF EQUIPMENT IS OVER 400,000 BTU PER HOUR INPUT = 1 HOUR
ROOMS WITH BOILERS WHERE THE LARGEST PIECE OF EQUIPMENT IS OVER 15 PSI AND 10 HP = 1 HOUR
FIRE-RESISTANCE RATING REQUIREMENTS FOR BUILDING ELEMENTS FROM TABLE 601
FOR TYPE IB:
PRIMARY STRUCTURAL FRAME : 2 HR
BEARING WALLS INTERIOR/EXTERIOR : 2 HR
NON-BEARING WALLS AND PARTITIONS INTERIOR : 0 HR
FLOOR CONSTRUCTION AND ASSOCIATED SECONDARY STRUCTURE : 2 HR
ROOF CONSTRUCTION AND ASSOCIATED SECONDARY STRUCTURE : 1 HR
FIRE-RESISTANCE RATING REQUIREMENTS FOR EXTERIOR WALLS BASED ON FIRE SEPARATION DISTANCE FROM TABLE 602
IF FIRE SEPARATION DISTANCE ≥30 FEET, FOR ALL CONSTRUCTION TYPES = 0 HOURS
MAXIMUM AREA OF EXTERIOR WALL OPENINGS BASED ON FIRE SEPARATION DISTANCE AND DEGREE OF OPENING
PROTECTION FROM TABLE 705.8
IF FIRE SEPARATION DISTANCE IS 30 FEET OR GREATER FOR UNPROTECTED, NONSPRINKLERED
(UP, NS) OPENINGS = NO LIMIT
INTERIOR WALL AND CEILING FINISH REQUIREMENTS BY OCCUPANCY FROM TABLE 803.9
FOR GROUP B, NONSPRINKLERED:
EXIT ENCLOSURES AND EXIT PASSAGEWAYS = A
CORRIDORS = B
ROOMS AND ENCLOSED SPACES = C
OCCUPANT LOAD FACTOR FROM TABLE 1004.5
FIRST FLOOR BUSINESS AREAS = 5,501 SF / 150 SF = 37 OCCUPANTS
FIRST FLOOR WAREHOUSE AREAS = 60,836 SF / 500 SF = 122 OCCUPANTS
FIRST FLOOR STORAGE AREAS = 4,687 SF / 300 SF = 16 OCCUPANTS
FIRST FLOOR ASSEMBLY AREAS = 2,007 SF / 15 SF = 134 OCCUPANTS
TOTAL FIRST FLOOR OCCUPANT LOAD = 309 OCCUPANTS / 10 EXITS = 31 OCCUPANTS PER EXIT
MINIMUM REQUIRED EGRESS WIDTH FROM SECTION 1005.3.2
OTHER EGRESS COMPONENTS = 309 x 0.2 = 61.8 INCHES REQUIRED, 360" INCHES PROVIDED
COMMON PATH OF EGRESS TRAVEL FROM SECTION 1006.2.1 = SHALL NOT EXCEED 100 FEET W/ SPRINKLER SYSTEM
SPACES WITH ONE EXIT OR EXIT ACCESS DOORWAY FROM TABLE 1006.2.1
FOR F-1 OCCUPANCY, MAXIMUM OCCUPANT LOAD = 49
EXIT ACCESS TRAVEL DISTANCE FROM TABLE 1017.2
FOR F-1 OCCUPANCY, WITH SPRINKLER SYSTEM = 250 FEET
CORRIDOR FIRE-RESISTANCE RATING FROM TABLE 1020.1
FOR F-1 OCCUPANCY, WITH SPRINKLER SYSTEM, IF OCCUPIED LOAD SERVED BY CORRIDOR IS GREAT THAN 30
= 0 HOUR RATING REQUIRED
DEAD END CORRIDORS FROM SECTION 1020.4 = NO MORE THAN 20 FEET
NO CHANGES TO PLUMBING FIXTURE REQUIREMENTS OR COUNT
MINIMUM NUMBER OF PLUMBING FIXTURES FROM TABLE 2902.1
BUSINESS OCCUPANCY = 18 MALES, 19 FEMALES
WATER CLOSET: REQUIRED : 0.72 MALES, 0.76 FEMALES
LAVATORIES:REQUIRED : 0.45 MALES, 0.48 FEMALES
ASSEMBLY OCCUPANCY = 67 MALES, 67 FEMALES
WATER CLOSET:REQUIRED : 1.68 MALES, 1.68 FEMALES
LAVATORIES:REQUIRED : 0.89 MALES, 0.89 FEMALES
STORAGE OCCUPANCY = 8 MALES, 8 FEMALES
WATER CLOSET:REQUIRED : 0.08 MALES, 0.08 FEMALES
LAVATORIES:REQUIRED : 0.08 MALES, 0.08 FEMALES
WAREHOUSE OCCUPANCY = 61 MALES, 61 FEMALES
WATER CLOSET:REQUIRED : 0.61 MALES, 0.61 FEMALES
LAVATORIES: REQUIRED : 0.61 MALES, 0.61 FEMALES
TOTAL WC PROVIDED: 8 MALES, 8 FEMALES, 3 GN (EXISTING, NO CHANGE)
TOTAL LAVATORIES PROVIDED:5 MALES, 5 FEMALES, 3 GC (EXISTING, NO CHANGE)
CODE REVIEW INFORMATION
M A X I M U M O V E R A L L D I A G O N A L : 4 9 2 '
KITCHENETTE
01.633
2007 SF
15 = 134
MOTHER'S
ROOM
01.103
BADGING
01.102
STORAGE
01.602
INTERVIEW
01.101
HUDDLE
01.104
INTERFAITH
PRAYER
01.105
TEAM ROOM
01.641
IDF
01.604
COMM
CENTER
01.605
CONF
01.203
BUSINESS
SELF-SERVICE
CENTER
01.201
BUSINESS
SERVICE
CENTER
01.202GENERATOR
01.629
FACILITY
MANAGEMENT
01.628
STORAGE
01.627
MDF
01.626
ELECTRICAL
01.624
SERVER
01.625
IDF
01.619
IDF
01.621
TEAM ROOM
01.613
WAREHOUSE
01.609
WAREHOUSE
01.635
WAREHOUSE
01.610
WAREHOUSE
01.620
WAREHOUSE
01.615
WAREHOUSE
01.614
WAREHOUSE
01.622
WAREHOUSE
01.623
20611 SF
500 = 42
1072 SF
500 = 3
1408 SF
500 = 3
15563 SF
500 = 32
11960 SF
500 = 24
1913 SF
150 = 13
5609 SF
500 = 12
1780 SF
500 = 4
WAREHOUSE
01.616
760 SF
300 = 3606 SF
300 = 3591 SF
300 = 2
272 SF
150 = 2
486 SF
150 = 4
755 SF
300 = 3
152 SF
300 = 1
BIKE
STORAGE
01.630
STORAGE
01.631
ELEC
102
FIRE
SUPPRESSION
101
153 SF
150 = 2 99 SF
150 = 1 123 SF
150
= 1
185 SF
150 = 2
640 SF
150 = 5
242 SF
300 = 1
99 SF
150 = 1
99 SF
150 = 1
236 SF
150 = 2
220 SF
150 = 2
215 SF
150 = 2
113 SF
150 = 1
70 SF
150
= 1 70 SF
150
= 1 88 SF
150 = 1 107 SF
150
= 1
99 SF
150 = 1
2525 SF
500 = 6
294 SF
300 = 1
310 SF
300 = 2 356 SF
300 = 2 307 SF
300 = 2
97 SF
150 = 1205 SF
150 = 2
308 SF
500 = 1
31
31
31
31
3131
31
31
31
31
31 x .2 = 6.2" REQUIRED
CLEAR EXIT WIDTH
36" PROVIDED
31 x .2 = 6.2" REQUIRED
CLEAR EXIT WIDTH
36" PROVIDED
31 x .2 = 6.2" REQUIRED
CLEAR EXIT WIDTH
36" PROVIDED
31 x .2 = 6.2" REQUIRED
CLEAR EXIT WIDTH
36" PROVIDED
31 x .2 = 6.2" REQUIRED
CLEAR EXIT WIDTH
36" PROVIDED
31 x .2 = 6.2" REQUIRED
CLEAR EXIT WIDTH
36" PROVIDED
31 x .2 = 6.2" REQUIRED
CLEAR EXIT WIDTH
72" PROVIDED
31 x .2 = 6.2" REQUIRED
CLEAR EXIT WIDTH
36" PROVIDED
31 x .2 = 6.2" REQUIRED
CLEAR EXIT WIDTH
36" PROVIDED
31 x .2 = 6.2" REQUIRED
CLEAR EXIT WIDTH
36" PROVIDED
01.617
VESTIBULE
01.607
VESTIBULE
01.603
VESTIBULE
01.601
RECEPTION
49 SF
300 = 1
01.636
ACP RETAIL
108
MEN'S RR
109
WOMEN'S RR
106
RR
107
RR
105
JANITOR
103
RR
N.I.C.
N.I.C.
4'
-
6
"
3'-0"
AREA OF NEW WORK
ALL DIMENSIONS AND CONDITIONS MUST BE CHECKED AND VERIFIED
ON SITE BY THE CONTRACTOR AND SUB-CONTRACTORS. THE PROJECT
MANAGER SHALL BE NOTIFIED IN WRITING OF ANY DISCREPANCIES
PRIOR TO PROCEEDING WITH THE WORK.
Sheet Title:
Designer:
Consultant:
Project Manager:
Reviewed By:
Approved By:
Project No:
Drawn By:
Project Title & Address:
Seal:
City Approval:
11
/
1
5
/
2
0
2
4
1
:
3
7
:
2
4
P
M
G101
CODE PLAN
Designer
DH
BS
BC
281_P-467002
BS
281_P467002
601 MONSTER ROAD SW, RENTON, WA
98057
Description: No: By: Date:
1/16" = 1'-0"G101
1 FIRST FLOOR CODE PLAN
NORTH REF
EMEARSA
T
O
ISH
NG
N
NE RED
NRE
E
E IG
WOFE
TAT
A
TS
IO
G
N
I
S
S
O
EFS
ER
46161
L
A
R
P
D
G
N
S
U
T
B2
5
0
0
0
0
6
2
_
V
1
RECEIVED
01/06/2025 striplett
BUILDING DIVISION
SPECIAL INSPECTION REQ'D
FOR HILTI BOLT INSTALLATION
CR CR
NOTE: ALL DIMENSIONS, ELEVATIONS AND LOCATIONS OF
EXISTING STRUCTURAL COMPONENTS ARE BASED ON
INFORMATION GATHERED FROM ORIGINAL OR CURSORY FIELD
MEASUREMENTS AND ARE SHOWN FOR INFORMATION ONLY.
CONTRACTOR SHALL FIELD MEASURE AND VERIFY ALL
CONDITIONS PRIOR TO COMMENCING ANY WORK. NOTIFY
ENGINEER WHERE CONDITIONS VARY FROM THOSE SHOWN.
______________
S102
1
ALL DIMENSIONS AND CONDITIONS MUST BE CHECKED AND VERIFIED
ON SITE BY THE CONTRACTOR AND SUB-CONTRACTORS. THE PROJECT
MANAGER SHALL BE NOTIFIED IN WRITING OF ANY DISCREPANCIES
PRIOR TO PROCEEDING WITH THE WORK.
Sheet Title:
Designer:
Consultant:
Project Manager:
Reviewed By:
Approved By:
Project No:
Drawn By:
Project Title & Address:
Seal:
City Approval:
11
/
1
1
/
2
0
2
4
2
:
2
9
:
3
3
P
M
S101
FOUNDATION PLAN
MENGSTU
-
-
GLEASON
281_P-467002
281_P467002
601 MONSTER ROAD SW, RENTON, WA
98057
1/16" = 1'-0"S101
1 OVERALL FLOOR PLAN
NORTH REF
Description: No: By: Date:
STRUCTURAL GENERAL NOTES
STRUCTURAL GENERAL NOTES ARE INTENDED TO HIGHLIGHT OR IN SOME CASES SUPPLEMENT
PROJECT SPECIFICATIONS. REFER TO THE PROJECT SPECIFICATIONS FOR COMPLETE WORK
COVERAGE.
A. GOVERNING CODES
1)INTERNATIONAL BUILDING CODE (IBC), 2021 EDITION.
2)MINIMUM DESIGN LOADS AND ASSOCIATED CRITERIA FOR BUILDINGS AND OTHER STRUCTURES,
ASCE/SEI 7-16.
3) BUILDING CODE REQUIREMENTS FOR STRUCTURAL CONCRETE, ACI 318-19.
B. DESIGN LOADS AND CRITERIA
1) GRAVITY LOADS, MAIL SORTER EQUIPMENT:
1. UTURN MODULE, WEIGHT: 880 LBS.
2. MMS STACKER MODULE, WEIGHT: 650 LBS (QTY 6).
3. SIM MODULE, WEIGHT: 870 LBS.
4. I/O MODULE, WEIGHT: 775 LBS.
5. FEEDER MODULE, WEIGHT: 2,230 LBS.
2)SEISMIC CRITERIA:
a)SS = 1.466 g / S1 = 0.499 g MAPPED MCER VALUES
b) RISK CATEGORY = II
c)PROJECT SITE CLASS = D
d)Ie = 1.00
e) SDS = 0.977 g DESIGN RESPONSE COEFFICIENT
f) SEISMIC DESIGN CATEGORY = D
g) ANALYSIS PROCEDURE: CHAP 13 NONSTRUCTURAL COMPONENTS
C. MATERIALS SECTION
1) STRUCTURAL STEEL:
a) PLATES AND BARS: ASTM A36, Fy = 36 ksi
2) NUTS: ASTM A563 GRADE DH PLAIN; STEEL TO STEEL CONNECTIONS
3) WASHERS: ASTM F436 TYPE 1 PLAIN; STEEL TO STEEL CONNECTIONS
4)SCREW ANCHORS:
a)CONCRETE: ASTM B633, CLASS SC1, TYPE III SUCH AS (HILTI KH-EZ) ICC-ES REPORT ESR-3027 OR
APPROVED EQUAL
D. MISCELLANEOUS
1)CONTRACTOR SHALL REVIEW AND VERIFY ALL DIMENSIONS SHOWN ON THE CONSTRUCTION
DOCUMENTS AND SHALL NOTIFY THE ENGINEER OF ANY DISCREPANCIES BETWEEN ARCHITECTURAL
AND STRUCTURAL DRAWINGS PRIOR TO PROCEEDING WITH CONSTRUCTION.
2)USE ONLY WRITTEN DIMENSIONS FOR CONSTRUCTION. WHERE NO DIMENSION IS PROVIDED,
CONSULT THE ENGINEER FOR CLARIFICATION PRIOR TO CONSTRUCTION.
3)DETAIL MARKS ANNOTATED ON PLANS ARE INTENDED TO INDICATE SPECIFIC CONFIGURATION(S)
AND INFORMATION. FOR PLAN CLARITY, NOT EVERY LOCATION WHERE A SPECIFIC DETAIL MAY
APPLY IS ANNOTATED. CONTACT THE ENGINEER IF CLARIFICATION IS NEEDED.
4)COORDINATE OPENINGS AND EMBEDDED ITEMS IN CONCRETE AND MASONRY WORK WITH ALL
TRADES.
5) NOTIFY ENGINEER OF ANY DISCREPANCIES DISCOVERED WITH OTHER TRADES.
6)CONSTRUCTION LOADS SHALL NOT BE GREATER THAN THE DESIGN LOADS INDICATED IN DESIGN
LOADS AND CRITERIA SECTION B.1, UNLESS REVIEWED AND APPROVED BY THE ENGINEER.
7)COSTS ASSOCIATED WITH STRUCTURAL DRAWING CHANGES RESULTING FROM USE OF ALTERNATES
OR SUBSTITUTIONS, INCLUDING MECHANICAL EQUIPMENT, IS THE CONTRACTOR'S RESPONSIBILITY.
8)CONTRACTOR IS RESPONSIBLE FOR LOCATING, PROTECTING AND STABILIZING ALL ADJACENT
STRUCTURES AND UTILITIES THROUGH ALL PHASES OF CONSTRUCTION.
9)STRUCTURAL GENERAL NOTES SHALL NOT BE A SUBSTITUTE FOR THE PROJECT SPECIFICATIONS.
CONFLICTS BETWEEN THE STRUCTURAL GENERAL NOTES AND PROJECT SPECIFICATIONS SHALL BE
BROUGHT TO THE ATTENTION OF THE ENGINEER OR THE STRICTER OF THE TWO CRITERIA SHALL BE
USED.
EMEARSA
T
O
ISHN
G
N
NE RED
NRE
E
E IG
WOFE
TAT
A
TS
IO
G
N
I
S
S
O
EF
S
ER46161
L
A
R
P
D GN
S
U
T
B2
5
0
0
0
0
6
2
_
V
1
RECEIVED
01/06/2025 striplett
BUILDING DIVISION
MMS STACKER MODULE,
QTY 6 (WT=650#)
WXLXH=94.3"X34.3"X55.8"
SEE
UTURN MODULE,
QTY 1 (WT=880#)
WXLXH=64"X44.5"X72")
SEE
SIM MODULE.
QTY 1 (WT=870#)
WXLXH=35.4"X44.9"X56.3"
SEE
I/O MODULE,
QTY 1 (WT=775#)
WXLXH=64.2"X44.8"X56.3"
SEE
FEEDER MODULE,
QTY 1 (WT=2,230#)
WXLXH=125.2"X50.2"X71.7"
SEE
4/S102
6/S102
5/S102
3/S102
2/S102
3'-0"
4'
-
6
"
38.7"
5
0
.
6
"
5
5
.
7
"
UTURN MODULE,
QTY 1 (WT=880#)
WXLXH=64"X44.5"X72"
EXIST 6" CONC
SLAB ON GRADE
SIDE ELEVATION BOTTOM PLAN
SEISMIC TIE PL BY MFR
(4 TOTAL)
EQUIP TO REST ON
ADJUSTABLE LEVELLING
FEET (4 TOTAL)
7
S102
______________
ADJUSTABLE
LEVELING FOOT
SEISMIC TIE PL BY MFR
W/ 3/8"Ø HILTI KWIK
HUS-EZ SCREW (2" EMB)
MODULE, SEE PLAN
CASTERS TO REMAIN
EXIST 6" CONC
SLAB ON GRADE
NOTE: ANCHOR BOLTS SHALL BE LOCATED
A MINIMUM OF 6" AWAY FROM ANY
CONCRETE JOINTS OR EDGE OF SLAB
SIDE ELEVATION
8
1
.
3
"
25.1"
MMS STACKER MODULE,
QTY 6 (WT=650#)
WXLXH=94.3"X34.3"X55.8"
EXIST 6" CONC
SLAB ON GRADE
BOTTOM PLAN
SEISMIC TIE PL BY MFR
EQUIP TO REST ON
ADJUSTABLE LEVELLING
FEET (4 TOTAL)
7
S102
______________
5
5
.
8
"
5
6
.
3
"
SIDE ELEVATION
7
S102
______________
BOTTOM PLAN
SIM MODULE,
QTY 1 (WT=870#)
WXLXH=35.4"X44.9"X56.3"
EXIST 6" CONC
SLAB ON GRADE
SEISMIC TIE PL BY MFR
(4 TOTAL)
EQUIP TO REST ON
ADJUSTABLE LEVELLING
FEET (4 TOTAL)
1
5
"
38.5"
5
6
.
3
"
7
S102
______________
SIDE ELEVATION
BOTTOM PLAN
I/O MODULE,
QTY 1 (WT=775#)
WXLXH=64.2"X44.8"X56.3"
EXIST 6" CONC
SLAB ON GRADE
SEISMIC TIE PL BY MFR
(4 TOTAL)
EQUIP TO REST ON
ADJUSTABLE LEVELLING
FEET (4 TOTAL)
43.7"
3
9
.
5
"
5
6
"
7
S102
______________
SIDE ELEVATION
FEEDER MODULE,
QTY 1 (WT=2,230#)
WXLXH=125.2"X50.2"X71.7"
EXIST 6" CONC
SLAB ON GRADE
SEISMIC TIE PL BY MFR
AT OPP SUPPORTS AS
SHOWN (4 TOTAL)
EQUIP TO REST ON
ADJUSTABLE LEVELLING
FEET (8 TOTAL)
104.7"
3
9
.
5
"
BOTTOM PLAN
ALL DIMENSIONS AND CONDITIONS MUST BE CHECKED AND VERIFIED
ON SITE BY THE CONTRACTOR AND SUB-CONTRACTORS. THE PROJECT
MANAGER SHALL BE NOTIFIED IN WRITING OF ANY DISCREPANCIES
PRIOR TO PROCEEDING WITH THE WORK.
Sheet Title:
Designer:
Consultant:
Project Manager:
Reviewed By:
Approved By:
Project No:
Drawn By:
Project Title & Address:
Seal:
City Approval:
11
/
1
1
/
2
0
2
4
2
:
2
9
:
3
5
P
M
S102
EQUIPMENT PLAN
MENGSTU
-
-
GLEASON
281_P-467002
281_P467002
601 MONSTER ROAD SW, RENTON, WA
98057
NORTH REF
1/4" = 1'-0"S102
1 ENLARGED EQUIPMENT PLAN
Description: No: By: Date:
3/4" = 1'-0"S102
2 UTURN MODULE
3/4" = 1'-0"S102
7 SECTION
3/4" = 1'-0"S102
3 MMS STACKER MODULE
3/4" = 1'-0"S102
4 SIM MODULE
3/4" = 1'-0"S102
5 I/O MODULE
3/4" = 1'-0"S102
6 FEEDER MODULE
EMEARSA
T
O
ISHN
G
N
NE RED
NRE
E
E IG
WOFE
TAT
A
TS
IO
G
N
I
S
S
O
EF
S
ER46161
L
A
R
P
D GN
S
U
T
B2
5
0
0
0
0
6
2
_
V
1
RECEIVED
01/06/2025 striplett
BUILDING DIVISION
REVIEWED
By: Alan Findlay, P.E.
Date: 02/07/2025