HomeMy WebLinkAboutR-4337002ABBREVIATIONS GENERAL NOTES co co i w LEGEND/SYMBOLS SECTION LETTER 0S CEILING MOUNTED OCCUPANCY SENSOR OR DETAIL NUMBER DESIGNATION & AND JT JOINT s SWITCH, OS INDICATES INTEGRAL OCCUPANCY SENSOR, D INDICATES BUILDING, WALL SECTIONS INTEGRAL DIMMER @ AT 1. OBTAIN & POST REQUIRED CONSTRUCTION PERMITS FROM THE CITY OF RENTON PRIOR TO COMMENCING CONSTRUCTION. C s AB ANCHOR BOLT 15A, 120V DUPLEX RECEPTACLE ACP ACOUSTICAL CEILING PANEL #X � X FIRE SPRINKLER HEAD ALUM ALUMINUM � AND DETAIL REFERENCES O INTERCOM/SPEAKER KO KNOCK OUT 2. VERIFY ALL EXISTING CONDITIONS AND NOTIFY THE BOEING PROJECT CONSTRUCTION MANAGER SHOULD CONDITIONS DIFFER FROM DESIGN DOCUMENTS. �I SHEET NUMBER WHERE DETAILED ACT ACOUSTICAL CEILING TILE L LENGTH 3. THE SCOPE OF WORK INCLUDES ALL WORK WITHIN THE CURRENT REVISION CLOUD(S) ON EACH SHEET. IF THERE IS NO CLOUD ON A SHEET THE ENTIRE 20 20A, 120V, DUPLEX RECEPTACLE ADJ ADJACENT SHEET IS IN THE SCOPE OF WORK. INFORMATION OR WORK (WHETHER CLOUDED OR NOT) REFERRED TO FROM WITHIN A CLOUD IS INCLUDED IN THE SCOPE SHEET NUMBER REFERENCED FROM # 15A, 120V, FOURPLEX RECEPTACLE AFF ABOVE FINISHED FLOOR LB LAG BOLT OF WORK (I.E. — A SECTION OR DETAIL SYMBOL THAT LIES WITHIN A CLOUD ON A PLAN VIEW SHEET IS INCLUDED IN THE SCOPE EVEN WHEN THE ACTUAL ----� xx AGG AGGREGATE LEN LENGTH SECTION OR DETAIL DRAWN ON THE DETAIL SHEET IS NOT CLOUDED.) X REFERENCE TO DETAIL/ENLARGED PLAN ( 1 ❑F o FIRE ALARM HORN/STROBE, xx INDICATES CANDELA RATING AL ALUMINUM LF LINEAL FEET i DATA/TELEPHONE OUTLET ALT ALTERNATE LL LIVE LOAD 4. KEEP ALL AREAS UNDER CONSTRUCTION CLEAR OF DEBRIS CAUSED BY THIS SCOPE OF WORK. STORE CONSTRUCTION MATERIALS AND EQUIPMENT IN AREA # X # ( I • LWR LOWER DESIGNATED BY THE BOEING PROJECT CONSTRUCTION MANAGER. 0 ROOF/ACCESS HATCH MATL MATERIAL ANCH ANCHOR ANCHORAGE 5. VERIFY DIMENSIONS AND CONDITIONS SHOWN ON THE DRAWINGS AND ENSURE THAT THE JOINING OF THE WORK OF VARIOUS TRADES MEETS APPROPRIATELY. X DETAIL DESIGNATION APA AMERICAN PLYWOOD ASSOC. MAX MAXIMUM BRING DISCREPANCIES ON THE DRAWINGS OR IN SPECIFICATIONS TO THE ATTENTION OF THE BOEING PROJECT CONSTRUCTION MANAGER IMMEDIATELY UPON APPD APPROVED DISCOVERY. THE CONTRACTOR SHALL ADVISE BOEING, SUMMARIZE THE SITUATION AND PROVIDE RECOMMENDATIONS TO RESOLVING POTENTIAL CONFLICTS PRIOR SHEET NUMBER WHERE DETAILED MBR MEMBER XXXX TOILET APPROX APPROXIMATE MB MACHINE BOLT TO SUBMITTING ANY REQUESTS FOR INFORMATION (RFIs). (IF SAME AS SHEET REFERENCED FROM) ASTM AMERICAN SOCIETY OF MTL METAL 6. CONFORM ALL WORK TO APPLICABLE CODES, REGULATIONS AND INDUSTRY STANDARDS. URINAL TESTING MATERIALS MFR X SECTION/DETAIL DESIGNATION MIN MINIMUM 7. COMPLY WITH THE BOEING PROJECT CONSTRUCTION MANAGER FOR CONSTRUCTION AREA AND SECURITY REGULATIONS. BTWN BETWEEN XXXXX XXXXX~ SHEET NUMBER WHERE DETAILED O LAVATORY BLDG BUILDING MISC MISCELLANEOUS 8. PROVIDE, AS IF DRAWN IN FULL, REPETITIVE FEATURES NOT FULLY SHOWN OR NOTED ON THE DRAWINGS. BLKG BLOCKING MO MASONRY OPENING BOT BOTTOM MT MOUNT(ED) (ING) 9. DIMENSIONS ON DRAWINGS ARE TAKEN TO THE FACE OF MASONRY AND/OR CONCRETE WALLS, METAL STUDS, AND TO THE CENTERLINE OF COLUMNS, SHEET NUMBER REFERENCED FROM MOP SINK MTL METAL UNLESS OTHERWISE NOTED. C CHANNEL DF DRINKING FOUNTAIN CB CATCH BASIN N NORTH (COORDINATE) 10. DOOR OPENINGS ARE 6" FROM ADJACENT WALLS OR CENTERED IN ROOM WALL, UNLESS DIMENSIONED OTHERWISE. NORTH ARROW CC CENTER TO CENTER NF NEAR FACE 11. PARTITIONS SHALL RUN FULL HEIGHT, FROM FLOOR TO FLOOR ABOVE UNLESS SHOWN OR NOTED OTHERWISE. 0 CEM CEMENT NIC NOT IN CONTRACT 0 o SANITARY NAPKIN/TAMPON DISPENSER CIF CUBIC FEET NO. NUMBER 12. PLANS WHICH APPEAR AS "BACKGROUNDS" ON CIVIL, STRUCTURAL, PLUMBING, HVAC, ELECTRICAL DRAWINGS ETC., ARE FOR THE PURPOSE ONLY OF CJ CONTROL JOINT NOM NOMINAL ILLUSTRATING GENERAL PLAN CONFIGURATION. SUCH BACKGROUNDS SHALL NOT BE USED FOR PORTIONS OF THE WORK OTHER THAN THAT PERTAINING TO THE Adk ELEVATION DATUM ° CL CENTER LINE NTS NOT TO SCALE TITLE OF EACH SHEET. REFER TO THE APPROPRIATE SHEET FOR EACH SPECIFIC PORTION OF THE WORK. IT OR SPOT ELEVATION CLG CEILING ® CA OVERALL 13. COORDINATE THE WORK OF ALL TRADES. REFER TO ARCHITECTURAL, STRUCTURAL, MECHANICAL AND ELECTRICAL DRAWINGS IN DETAIL FOR COORDINATION PAPER TOWEL DISPENSER/DISPOSAL CLR CLEARANCE) O/C OF SPECIFIC TRADE REQUIREMENTS. COORDINATE ALL ROUGH —IN REQUIREMENTS FOR EQUIPMENT FURNISHED BY CONTRACTOR OR BY OTHERS FOR THIS CEILING HEIGHT A.F.F. COL COLUMN 0/C ON CENTER PROJECT. COMP COMPRESSED) (ION) OD OUTSIDE DIAMETER DOUBLE ROLL TOILET PAPER DISPENSER CONC CONCRETE OF OUTSIDE FACE 14. PROVIDE MANUFACTURERS INSTALLATION INSTRUCTIONS TO THE BOEING PROJECT CONSTRUCTION MANAGER WHENEVER SUCH INSTRUCTIONS ARE REFERENCED XXXXXX OFCI OWNER FURNISHED CONTRACTOR IN THE CONSTRUCTION NOTES. ROOM NAME CONN CONNECTION HANDICAP GRAB BAR, 1 1/2" O.D. INSTALLED XXXX ROOM NUMBER CONTT CONSTRUCTION OPG OPENING 15. CONTRACTOR SHALL COORDINATE WITH THE BOEING PROJECT CONSTRUCTION MANAGER FOR STAGING AREAS WHERE CONTRACTOR MAY STORE SALVAGED TOILET SEAT COVER DISPENSER CONT CONTINUOUS, CONTINUE OPP OPPOSITE, OPPOSITE HAND MATERIALS TO BE REUSED IN LATER PARTS OF THIS PROJECT AND WHERE MATERIALS TO BE STAGED BY BOEING ARE TO BE LOCATED. XX DOOR NUMBER CONTR CONTRACT(OR) CT CERAMIC TILE PAR PARALLEL 16. SYMBOLS SHOWN ON MATERIALS LIST ARE NOT ALWAYS USED IN DRAWINGS. VERIFY EXISTING MATERIAL AND SEE CONSTRUCTION NOTES FOR MATERIAL EARTH, DIRT, UNDISTURBED CTSK COUNTERSUNK PCC PRECAST CONCRETE CALLOUTS. X PARTITION/WALL TYPE CY CUBIC YARD(S) PCF POUNDS PER CUBIC FOOT 17. WHERE EXISTING WORK IS DAMAGED, CUT OR DEFACED AS A RESULT OF DEMOLITION OR PERFORMANCE OF NEW WORK, THE CONTRACTOR IS TO PATCH AND PERF PERFORATE(D) REPAIR THE EXISTING TO MATCH ADJOINING SURFACES. REPAIRED FINISHES SHALL BE EXTENDED TO THE NEAREST VISUAL BREAK LINES SUCH AS CORNERS, EARTH, DIRT, COMPACTED 0, DIA DIAMETER PERIM PERIMETER CEILING LINES, TOP OF BASE, CHANGE IN MATERIAL OR SIMILAR. DBL DOUBLE PL PLATE 18. ALL RECESSES LOCATED WITHIN FIRE RATED PARTITIONS SHALL BE CONSTRUCTED TO MAINTAIN REQUIRED FIRE RATING OF THE PARTITION. X INTERIOR ELEVATION STONE, GRAVEL, POROUS FILL DEMOL DEMOLISH, DEMOLITION PLAM PLASTIC LAMINATE XXX XXX (WHERE SPACE IS LIMITED) DEP DEPRESSED PLYWD PLYWOOD 19. ARCHITECTURAL REFLECTED CEILING PLANS INDICATE THE FINAL LOCATIONS OF MECHANICAL AND ELECTRICAL COMPONENTS. SEE THE REFLECTED CEILING DIA DIAMETER PNL PANEL PLANS FOR LOCATIONS OF ITEMS IN THE CEILING; SEE DISCIPLINE SHEETS FOR ALL INFORMATION ABOUT THE MECHANICAL AND ELECTRICAL COMPONENTS BRICK, COMMON DIAG DIAGONAL PRIEST PRESTRESSED) INDICATED ON ARCHITECTURAL REFLECTED CEILING PLANS. REVISION CLOUD WITH DIM DIMENSION PRF PREFORMED REVISION LETTER "BEAK" DL DEAD LOAD PRF POUNDS PER SQUARE FOOT 20. PROVIDE CLOSURE, MEETING THE REQUIREMENTS OF GOVERNING FIRE AUTHORITIES, BETWEEN ALL FIRE RATED FLOORS, SHAFTS AND BUILDING PARTITIONS CERAMIC TILE DN DOWN PSI POUNDS PER SQUARE INCH AND ALL PENETRATING DUCTS, PIPES, CONDUIT, MECHANICAL, ELECTRICAL, AND OTHER ITEMS. A DS DOWNSPOUT PT POINT, PAINT 21. THE CONTRACTOR IS RESPONSIBLE FOR REVIEW OF THE STRUCTURAL, MECHANICAL AND ELECTRICAL DRAWINGS FOR CUTTING AND PATCHING WORK WITHIN CONCRETE DWG DRAWING PVC POLYVINYL CHLORIDE THE BUILDING, BEYOND THE LIMITS OF THE ARCHITECTURAL DRAWINGS. E EAST (COORDINATE) R RADIUS (CURVATURE) 22. AT METAL STUD PARTITIONS, STUDS ARE TO EXTEND FROM FLOOR TO FLOOR U.N.O.. WHERE THEY CANNOT DO SO, DUE TO INTERFERENCE WITH NEW OR EA EACH R RISER EXISTING DUCTS, PIPING, ETC., PROVIDE BRACING TO STRUCTURE ABOVE TO PROVIDE FOR EQUIVALENT SUPPORT OF PARTITION; SUBMIT EQUIVALENT SUPPORT VCT CPT FLOOR MAT'L TRANSITION INSULATION: BATT, LOOSE FILL, BLANKET EB EXPANSION BOLT RIB RESILIENT BASE METHOD TO ARCHITECT FOR REVIEW. ALL FIRE RATED PARTITIONS SHALL BE CONSTRUCTED TO MAINTAIN THEIR RATING FROM FLOOR TO UNDERSIDE OF EF EACH FACE REF REFERENCE, REFER TO STRUCTURE ABOVE, U.N.O. Mor// l INSULATION: RIGID EJ EXPANSION JOINT REINF REINFORCE(D) (ING) 23. PROVIDE ACCESS DOORS AS INDICATED OR AS NECESSARY AND VERIFY WITH MECHANICAL AND ELECTRICAL SUBCONTRACTORS EXACT LOCATIONS OF ACCESS FLOOR RECESS EL ELEVATION REQ REQUIRED) (ING) REQUIRED BY THEIR WORK. ACCESS MUST BE PROVIDED FOR ALL CONCEALED VALVES, DAMPER CONTROLS, FIRE DAMPER LINKAGES, CONCEALED JUNCTION ELEV ELEVATION REV REVISION(S), REVISED BOXES, AND ELECTRICAL DEVICES OR ACCESSORIES. LOCATIONS AND SIZES OF EXPOSED ACCESS DOORS SHALL BE SUBMITTED TO THE ARCHITECT FOR REVIEW n EQ EQUAL RH RIGHT HAND PRIOR TO INSTALLATION OF THE MECHANICAL AND ELECTRICAL EQUIPMENT. END WALL GUARD ALUMINUM EW EACH WAY RO ROUGH OPENING 24. THE CONTRACTOR SHALL BE RESPONSIBLE FOR SAFETY IN THE AREA OF WORK IN ACCORDANCE WITH ALL SAFETY CODES, REGUALTIONS AND BOEING EXIST EXISTING REQUIREMENTS. CORNER GUARD BRASS, BRONZE, COPPER EXP EXPOSED S SOUTH (COORDINATE) I EXT EXTERIOR SECT SECTION 25. THE CONTRACTOR SHALL RETAIN A FIRE PROTECTION ENGINEER LICENSED IN THE STATE OF WASHINGTON TO DETERMINE/DESIGN THE MODIFIED FIRE SF SQUARE FEET SPRINKLER SYSTEM LAYOUT WITHIN THE AREA OF WORK. SAID ENGINEER SHALL STAMP, SEAL AND CERTIFY THAT HIS/HER DESIGN IS IN COMPLIANCE W/ALL FINISH DESIGNATION METAL, STEEL, IRON FAs FASTEN(ER) SHT SHEET APPLICABLE CODES AND REGULATIONS. CONTRACTOR SHALL COORDINATE ALL NECESSARY MODIFICATIONS AS A RESULT OF SAID ENGINEER'S DESIGN. CPT-1 FF FINISHED CEILING SIM SIMILAR 26. PORTIONS OF THE BUILDING WILL BE OCCUPIED DURING CONSTRUCTION. THE CONTRACTOR SHALL COORDINATE ALL WORK TO AVOID AS MUCH AS CD — GRID/GRID BUBBLE AND PLASTER: SAND, CEMENT, GROUT FF FACTORY FINISH SQ SQUARE POSSIBLE ANY INCONVENIENCE TO BUILDING OCCUPANTS AND PROVIDE FOR THEIR SAFETY, ACCESS AND EGRESS THROUGHOUT THE PROJECT WORK. THE CENTERLINE FF FINISHED FLOOR SST, SS STAINLESS STEEL CONTRACTOR SHALL FULLY SCREEN OFF AREAS UNDER CONSTRUCTION BY TEMPORARY SCREENS OR PARTITIONS AS NECESSARY TO LIMIT DUST, DIRT, NOISE, FGR FINISH GRADE ST STRUCTURAL TEE FUMES OR OBJECTIONABLE ODORS FROM ENTERING OCCUPIED AREAS. --- --- --- -- CONSTRUCTION ABOVE OR PLASTER: GYPSUM WALL BOARD FH FIRE HYDRANT STD STANDARD BELOW, BEYOND OR BEHIND (HIDDEN) FIN FINISH(ED) STL STEEL FND FOUNDATION STR STRUCTURAL CONSTRUCTION "FLAG" NOTE FOR SPECIFIC WOOD: FINISH FOC FACE OF CONCRETE SYM SYMMETRY,SYMMETRICAL CONSTRUCTION DIRECTIVE FOF FACE OF FINISH SYS SYSTEM FOIC FURNISHED BY OWNER/ WOOD: ROUGH CONTINUOUS T&B TOP AND BOTTOM GENERAL "BOAT" NOTE FOR INSTALLED BY CONTRACTOR T&G TONGUE AND GROOVE ® SPECIFIC OR EXISTING HISTORICAL FO FINISHED OPENING TEMP TEMPORARY INFORMATION. WOOD: INTERRUPTED BLOCKING FRO FOR REFERENCE ONLY FT FOOT THK THICKNESS) TOC TOP OF CURB A WINDOW TYPE FTG FOOTING TOC TOP OF CONCRETE PLYWOOD: SMALL SCALE FUT FUTURE TOL TOLERANCE XXX HANDRAILS, KICK PLATES AND OTHER FV FIELD VERIFY TOS TOP OF STEEL PHYSICAL PROTECTION GA GAGE TS STRUCTURAL TUBE FEo- FIRE EXTINGUISHER CRFG GLASS FIBER REINFORCED GYPSUM PLYWOOD: LARGE SCALE TYP TYPICAL GALV GALVANIZED FEC FIRE EXTINGUISHER & CABINET GC GENERAL CONTRACTOR UBC UNIFORM BUILDING CODE i O ® UL UNDERWRITERS' LABEL Q SUPPLY AIR DIFFUSER WALL TYPE: CONCRETE MASONRY (CMU) GI GALVANIZED IRON LINO UNLESS NOTED OTHERWISE RETURN AIR GRILLE GR GRADE UPR UPPER GT GROUT FLOURESCENT LIGHT FIXTURE WALL TYPE: STEEL STUD GWB GYPSUM WALL BOARD VB VAPOR BARRIER (PENDANT MOUNTED) VC VINYL COMP. TILE HDNR HARDENER VERT VERTICAL FLOURESCENT LIGHT FIXTURE HDWD HARDWOOD (PENDANT MOUNTED) WALL TYPE: WOOD STUD HDWR HARDWARE WF W STVERI�IN FIELD (COORDINATE) FLOURESCENT LIGHT FIXTURE ON EMERGENCY NIGHT HG HIGH GRADE W WIDE FLANGE LIGHT (NL) CIRCUIT HM HOLLOW METAL W WIDTH, WIDE WALL TYPE: EXISTING O RECESSED OR PENDANT LIGHTING FIXTURE HORZ HORIZONTAL WC WATER CLOSET 0 RECESSED OR PENDANT LIGHTING FIXTURE HS HIGH STRENGTH WD WOOD ______ HT HEIGHT W/ WITH FLOURESCENT LIGHT FIXTURE ON EMERGENCY NIGHT WALL TYPE: REMOVAL W/0 WITHOUT LIGHT (NL) CIRCUIT IBC INTERNATIONAL BLDG. CODE WWF WELDED WIRE FABRIC R-433702 � WALL SCONCE 1 ID INSIDE DIAMETER b WALL SCONCE 2 S WALL TYPE: PARTITION (7'-0" HIGH) ID INSIDE DIMENSION NOTE: REFER TO THE COLOR AND MATERIAL ISSUE FOR CONSTRUCTION IF INSIDE FACE SCHEDULE FOR ADDITIONAL FINISH AND ro I I u d a architects ® EXIT SIGN (CEILING UNIT) IN INCH DESIGNATIONS/ABBREVIATIONS JAN UARY 24 2025 EXIT SIGN (WALL MOUNT) WALL TYPE: GLASS INCL INCLUDED(D) (ING) architecture planning interior design , 105 South Main Street, Suite 323, Seattle, WA 98104 206.624.4222 SYM REVISION BY APPROVED DATE SYM REVISION BY APPROVED DATE ACCEPTABILITY DRAWN DATE SUBTITLE CURRENT REVISION SYMBOI�-� R DATE 01.24.25 ORIG. RELOCATE MEDICAL CENTER 42657 HS/RAI EAC 01.24.25 6604 THIS DESIGN AND/OR CHECKED ABBREVIATIONS & SYMBOLS LEGEND 42657 U (�J SPECIFICATION IS APPROVED ENGINEER TITLE SHEET BOE//V� ®APPROVED BY DEPT. DATE RELOCATE MEDICAL CENTER G 1 G 1 ' CHECKED Q Q STAPPROVED BUILDING 04-088 JOB NO. 7��- m 42657 APPROVED ARCHITECTURAL MASTER EVERETT, WA DWG NO. 04-088-G1 J co N Cb 0 v 0 U Of W