Loading...
HomeMy WebLinkAboutR-4337013co Nt 0 W TOP OF DGRADE RUM SHALL BE 6" PROVIDE SOLID RUNOFF WITH �` COVER DISCHARGE SEDIMENT ,MIN ABOVE— '\\ o p o 55 GALLON DRUM WITH 2" DIAMETER WEEP HOLES WRAP WITH FILTER FABRIC WIRE TIES FILTERED \\�\�� \\� SUBMERSIBLE PUMP — RUNOFF kInTr. PUMPS SHALL BE SUBMERSIBLE, CONTRACTOR IS RESPONSIBLE FOR SIZING PUMP BASED ON FIELD CONDITIONS. 55-GALLON DRUM WITH PUMP SCALE: NTS I C\/CI DnTTnkA ON SLOPE GRADIENT SEE TABLE C31 C500 SWALL SPADNG AVERAGE SLOPE SLOPE PERCENT FLOWPATH LENGTH 20(H) : 1(V) 3-5% 300 FEET 10-20(H) 1(V) 5-10% 200 FEET 4-1 O(H) : 1(V) 10-25% 100 FEET 2-4(H) 1(V) 25-50% 50 FEET MAINTENANCE STANDARDS: 1. DAMAGE RESULTING FROM RUNOFF OR CONSTRUCTION ACTIVITY SHALL BE REPAIRED IMMEDIATELY. 2. IF THE FACILITIES DO NOT REGULARLY RETAIN STORM RUNOFF, THE CAPACITY AND/OR FREQUENCY OF THE DIKES/SWALES SHALL BE INCREASED. NTERCEPTOR SWALE DETA E SCALE: NTS �16111611I11 j DIRECTIONS FOR USE: • REMOVE DRAIN GRATE \/ • INSERT FILTER • REPLACE GRATE TO HOLD IN POSITION SPECIFICATIONS: • FILTERS MIN. 3 FEET DEEP • CONSTRUCTED OF WOVEN POLYPROPYLENE • SEAMS DOUBLE -STITCHED • PERM EABILITY-40GAL. PER MINUTE PER SQUARE FOOT • REUSABLE OR THROW -AWAY MAINTENANCE: • REMOVE WHEN FILLED TO HALF -WAY MARK (USE FRONT -LOADER OR OTHER EQUIPMENT FOR REMOVAL) • CLEAN AND RE -USE, OR REPLACE CATCH BASIN PROTECTION SCALE: NTS C310500 T\MCTCn QFI \/A('E- f`InTI70. 1. CHAIN LINK FABRIC TO BE MIN. 11 GAUGE, GALVANIZED, VINYL COATED. EXPOSED GALVANIZED COMPONENTS ARE NOT ALLOWED. 2. FENCE BASES SHALL BE OF SUFFICIENT WEIGHT AND/OR SPREAD TO ADEQUATELY SUPPORT EACH PANEL. 3. PANEL -TO -PANEL CONNECTIONS SHALL BE MADE AT A MIN. TWO LOCATIONS PER CONNECTION UNLESS OTHERWISE APPROVED. CONSTRUCTON CHANDNK FENCE SCALE: NTS C31 C500 BACK OF DITCH (TYP.) FRONT APROI` E REAR APRON STAPLES (TYF.) 3 FT. MAX. SPACING (`uC(`I/ nAKA BACK OF DITCH (TYP.) PLAN VIEW 6" OVERLAP DIG TRENCH APPROXIMATELY 6" WIDE AND DEEP, STAPLE END OF GEOTEXTILE AND BACKFILL WITH NATIVE MATERIAL ORIENT THE SEWN EDGE OF THE CHECK DAM TOWARD THE UPSTREAM SIDE A FLOW_ SECTION B—B FRONT APRON EAR PRON NOTES SECTION A —A ISOMETRIC VIEW 1. GEOTEXTIEE ENCASED CHECK DAMS SHALL MEET THE REQUIREMENTS OF THE 2014 WSDOT STANDARD SPECIFICATION 8-01.3(6)A AND 9-14.5(4). 2. INSTALL THE SLOPED ENDS OF THE CHECK DAM A MINIMUM OF 3" HIGHER THAN THE TOP OF THE CHECK DAM IN THE CHANNEL TO ENSURE THAT WATER FLOWS OVER THE DAM AND NOT AROUND IT. 3. FLAT BOTTOM DITCH DESIGN SHOWN, CHECK DAM INSTALLATION DETAILS ARE SIMILAR FOR "V" BOTTOM DITCHES. 4. PERFORM MAINTENANCE IN ACCORDANCE WITH THE 2014 WSDOT STANDARD SPECIFICATION 8-01.3(15). GEOTEXT LE ENCASED CHECK DAM r_4-� SCALE: NTS 1601 5th Avenue, Suite 1600 Seattle, WA 98101 206.622.5822 lq)ff www.kpff.com C31 C500 R-433713 ISSUE FOR CONSTRUCTION JAN UARY 24, 2025 SYM REVISION BY APPROVED DATE SYM REVISION BY APPROVED DATE - F ASgI` DKAWN DAIS SUBTITLE CURRENT REVISION SYMBOL DATE �ACCEPTABILITY C.MOUA 09.16.24 TESC DETAILS 42657 0R�G ORIG RELOCATE MEDICAL CENTER 42657 S.MEURN P.KASITYAP 09.16.24 �� �� THIS DESIGN AND/OR CHECKED 01.24.25 SPECIFICATION IS APPROVED P.CRAWFORD 09.16.24 SHEET SEQUENCE NO. _ 18ENGINEER TITLE RELOCATE MEDICAL CENTER C500 APPROVED BY DEPT. DATE P.CRAWFORD 09.16.24 clo 430 4 CHECKED Q �CISTEg�'� �y�S.MEURN 09.16.24 BUILDING 04-0 V Q V �SSIONAL EAPPROVED 42657 09/17/2024 APPROVED CIVIL MASTER RENTON, WA DWG NO. RTN-YD-0500 Q 0 00 cc 0 0 N �i rn M Q CD O CM O O It N