Loading...
HomeMy WebLinkAboutMFP24001937.pdfDEPARTMENT OF COMMUNITY AND ECONOMIC DEVELOPMENT Minor Franchise Permit: MFP24001937 IVR Number: 24001937 Permit Information Permit Name: Puget Sound Energy - Electric Address/Location:04/15/2024Application Date:1823059044Parcel Number: 408 S 7TH ST Permit Type:05/08/2024Issue Date:Franchise Permit Work Class:05/08/2025Expiration Date:Minor Utility Job Number: 101169535Franchise Type:Electric 09/04/2024Finalize Date: Description: Puget Sound Energy Electric CITY PUBLIC IMPROVEMENT WORK Shifting poles to the North within ROW for cities new sidewalk. Will need to reconnect 2 3 UG services at base of poles. Transfer some existing equipment on poles and replace others that no longer meet standard. Approved lay down locations for new poles located on site plan. Restoration per City of Renton standards. Contacts Name Address PhoneTypeBilling Corrie Rydberg Puget Sound Energy 3702 71st Ave W University Place, WA 98466 C: (253) 905-5031ApplicantX Vicki Henson Potelco Inc 8001 212th St S Kent, WA 98032 B: (253) 863-0484Contractor Business License Number: 5109Electrical Contractor: POTELI*344O4 Construction Contractor: POTELI*227PL Puget Sound Energy Inc 10885 NE 4th Street, PSE08-N08 Bellevue, WA 98009 B: (888) 225-5773Emergency Contact CITY OF RENTON ROW 1055 S Grady Way Renton, WA 98057-3232 Owner Corrie Rydberg Puget Sound Energy 3702 71st Ave W University Place, WA 98466 C: (253) 905-5031Specialized Billing General Conditions & Signature Permission is hereby given for the work described on this permit according to the conditions hereon and according to the approved plans and specifications pertaining thereto, subject to compliance with the Ordinance of the City of Renton. Ÿ This permit and plans must be posted at the job site at all times.Ÿ I hereby certify that no work is to be done except as described above and in approved plans, and that work is to conform to Renton Trench Restoration and Street Overlay Requirements. Ÿ Call 425.430.7203 or go to: https://permitting.rentonwa.gov one working day in advance to schedule an inspections and for ANY work in the Right of Way. Ÿ Call 8 1 1 to locate underground utilities at least two full business days prior to any excavation.Ÿ In accordance with RCW 19.122.033(4) the permit holder is required to contact (Williams Northwest Pipeline at 425.868.1010) (Olympic Pipeline at 425.235.7736) (Puget Sound Energy at 425.375.3397) to request a consultation with the transmission pipeline company prior to performing any construction or excavation activities. This requirement to consult with the transmission pipeline company is in addition to the requirement to Call before You Dig as required in RCW 19.122. Ÿ (Date)(Signature) Page 1 of 1THIS PERMIT AND PLANS MUST BE POSTED AT THE JOB SITE AT ALL TIMES Note: The Applicant is responsible for compliance with all codes and regulations, whether or not described in this document. DEPARTMENT OF PUBLIC WORKS Page 1 of 3 | Published: 10/27/2021 Transportation Division | 1055 South Grady Way, 5th Floor | Renton, WA 98057 | 425-430-7380 Website: rentonwa.gov TRAFFIC CONTROL PLAN APPLICATION Published: 10/27/2021 TRAFFIC CONTROL PLAN (TCP) MUST BE SUBMITTED TO PUBLIC WORKS TRANSPORTATION DIVISION FOR REVIEW/APPROVAL AT LEAST FIVE (5) WORKING DAYS BEFORE THE DATE OF WORK. The City of Renton requires any contractor, firm, corporation, or other public/private agency to prepare a traffic control plan (TCP) and obtain city's approval of that plan when construction, repair, or maintenance work is to be conducted within the city's right-of-way. 1. Fill out the Traffic Control Plan (TCP) Application form and prepare required submittal documents. 2. The following items are all required for submittal of the TCP Application: ☐ Electronic Copy of the TCP Application ☐ Electronic Copy of the TCP Layout, on 11” X 17” paper size format, which shall:  Include map(s) showing the location of the project and work area.  Be legible lettering and clear, contrasting, symbols of viewing or printing.  Must indicate street names, and north arrow and scale.  Types of plans required: o Work hour plan – show all mobility impacts during construction hours. o Non-work plan - show all mobility impacts after work hours when limited or no work is happening in the right-of-way (ROW), if applicable. o Changing construction phases – show construction sequence and each construction phase change even if the traffic control is not modified, if applicable. o Pedestrian access/detour plan, if applicable. - Shall conform to the Washington State Traffic Control Flagger Certification handbook, by the Evergreen Safety Council. 3. Submit Application via email to TCP@rentonwa.gov with the subject line “TCP Application – [Project Name].” Project Name: Permit #: Site Address: Work Date: From _____________ To _____________ Work Time: Start ______________ End ______________ Construction Company: Contact Name: Phone/Cell: _________________________ Business Address: City/State: Zip: Description of Work: Approval By: _________________________________________________ Date:____________________ Transportation Engineering S 7th St Corridor Improvements/PSE Pole Relocation MFP24001937 405 S 7th St (Between Burnett Ave S and Nelson Ln S 02/24/25 03/14/25 8 AM 5 PM (overnight outage on 2/27; 9 pm - 5 am) Potelco Dustin Weller 206-379-4347 355 110th Ave NE, Bellevue Bellevue 98004 PSE power pole and wire relocation/reconfiguration Monday Friday 3:00pm8:00am Scott Warlick CED 2/21/2025 Note: The Applicant is responsible for compliance with all codes and regulations, whether or not described in this document. Page 2 of 3 | Published: 10/27/2021 PERMIT HOLDER AGREES TO ALL THE FOLLOWING:  Must have approved Traffic Control Plan (TCP) prior to commencing the work.  Maintain existing pedestrian access. The work on pedestrian facilities, shall be limited to one corner at a time, with the least possible inconvenience or delay to pedestrians.  WORK TIME begins when any street or travel lane is fully or partially closed. This includes set up within the traveled way.  Comply with all traffic regulations of the City of Renton and the State of Washington.  Prepare a traffic control plan and obtain City approval of that plan. That plan shall be implemented for all street and lane closures, and the plan shall be performed in compliance with the Manual on Uniform Traffic Control Devices.  Notify emergency services (253-852-2121) twenty-four (24) hours before any street or lane closures.  Contractor or entity must call Renton School District (425-204-4455) or any public/private agency, including public transit, to be affected by a temporary lane or road closure a minimum of five business days (excluding weekends and holidays) prior to starting any work.  Contractor or entity must notify King County Metro in writing at construction.coord@kingcounty.gov a minimum of five business days (excluding weekends and holidays) prior to starting any work impacting bus stops, a temporary lane or road closure. Work requiring removing a bus shelter or sign requires notification in writing a minimum of 30 business days (excluding weekends and holidays). Please call King County Metro at 206-477-1140 with any questions.  Any lane or street closures not in conformance with the approved traffic control plan and/or without notification of emergency services may result in receiving a citation for violation of R.C.W. 47.36.200 Signs or Flaggers at thoroughfare work sites and R.C.W. 9A.36.050 Reckless Endangerment, and other applicable State and City codes.  Indemnify and hold harmless the City of Renton from any and all claims, actions, and judgments, including all costs of defense and attorney’s fees incurred in defending against same, arising from and related to implementation of the approved traffic control plans including claims arising from towing of private vehicles and the acts of the Permit Holder’s agents and employees.  The City of Renton shall be entitled, in its reasonable discretion, to settle claims prior to suit or judgment, and in such event shall indemnify and hold harmless the City for any such claims paid, including the City’s reasonable attorney’s fees and litigation costs incurred resulting from such claim.  In the event any claim or suit is brought against City within the scope of this Agreement, Permit Holder will pay for legal counsel chosen by the City to defend against same.  Flagger and sign placement are subject to revision by the City Inspector on site, if needed to address traffic or pedestrian safety or travel.  All permit conditions shall be met. NOTES:  Total road closure lasting more than twenty-four (24) hours is subject to the approval by the City Council.  Work Zone Traffic Control shall be in accordance with the Manual on Uniform Traffic Control Devices (MUTCD) and shown by a traffic control plan layout or reference to WSDOT.  Approved Temporary Traffic Control Plan must be at the work site during work hours.  Complete assistance and accommodation shall be provided to all kinds of pedestrian traffic when sidewalk or walkway is impeded to safely redirect pedestrians around a work zone.  Signage shall be used to warn motorcyclists/bicyclists of the potential hazards on any uneven surfaced or slippery road conditions during work and non-work hours.  Any vehicle, equipment, barricade, or portable tow-away sign used within the work area must display a company logo or any legally acceptable sign showing the company name, address, and telephone number at a conspicuous place on the vehicle or equipment. Note: The Applicant is responsible for compliance with all codes and regulations, whether or not described in this document. Page 3 of 3 | Published: 10/27/2021  In the case of Temporary No Parking Zones, all the following apply in addition to previous:  Contractor must complete form to show limits of Temporary No Parking Zone identifying barricade locations for vacate parking or curb lane usage.  Contractor must post notice of dates and time of Temporary No Parking Zone with at least two signs per block seventy-two (72) hours in advance of effective date and time.  The cover sheet of this Traffic Control Plan form must be attached to each Temporary No Parking Sign on the project site.  Temporary traffic control devices must be removed immediately when work is done or no construction activities are going on. If deemed abandoned, City crews will remove and store them at the City’s maintenance shop (3555 NE 2nd Street). I certify that the information on this application and within the submittal documents are accurate to the best of my knowledge and I acknowledge all the requirements on this application. Applicant’s Signature Date Applicant’s Name (Print) Dustin Weller 2/19/25 Dustin Weller MORRIS AVE S S 7TH STMOSES LN S SHATTUCK AVE S ONE LANE ROADAHEAD W20-4100'100'100'W20-7AONE LANEROADAHEADW20-4ROADWORKAHEADW20-1W20-7ABEPREPAREDTOSTOPW3-4100'100'100'ROADWORKAHEADW20-1W20-7AROADWORKAHEADW20-1121212121212WHITWORTH LN SP02NEW P03REMOVEONLYONLY 11 11 11 17 20 1818 S 7TH ST1111111111STOP STOP W20-1ROADWORKAHEADW20-4ONE LANEROADAHEADX'≥X'≥X'≥ W20-7A STOP 115ROAD WORK AHEAD W20-1BEPREPAREDTOSTOPW3-4X'≥X'≥X'≥ROADWORKAHEADW20-1X'≥X'≥BEPREPAREDTOSTOPW3-4ROADWORKAHEADW20-1X'≥X'≥RESIDENT(S) WILL BE INFORMED OFTEMPORARY DRIVEWAY CLOSURETHE CREW SHALL CEASEWORK AND ESCORT PEDESTRIANSAROUND/THRU WORK AREAFROM TO TOW AWAY AREA PHONE 684-5444 NAME OF FIRM XXX-XXX-XXXX NO PARKINGPLACE SIGNS BOTHSIDES OF WORK AREA405 S 7th St Renton WA 98057 USA0'60'30'NSIGN SPACINGMPH60/6545/5535/403025"X"1000'500'350'200'100'CHANNELIZATIONDEVICE SPACINGMPH55/7035/4525/30TAPER403020TANGENT806040Project Address:PagePSEPUGETSOUNDENERGYDesigner:Job #REVYURIY BASHTOVOY425-424-6425yuriy.bashtovoy@pse.com1 OF 14S 7TH ST CORRIDOR IMPROVEMENTS RENTON, WA 980571 1196436811/06/2024Notes:1. All signs and spacing to conform to theMUTCD and City of RENTON standards.2. All sidewalks, driveways, exits and egressesshall be completely clear unless otherwise indicated,if indicated use ADA compliant channelization.3. Channelizing devices are 28" traffic cones.Use traffic drums (barrels) with steady burningType C lights on all State State Routes and Hwys.4. Sign size can be a minimum of 36" x 36" andshall not obstruct pedestrian access.5. Crew is required to leave a minimum of 10' fortraveling lane width.6. Alert affected residents and businesses.7. Work to take place during approved work hours asper jurisdictional requirements. (Generally between 9a.m. and 4 p.m. on non-arterials and from 9 a.m. to 3p.m. on arterials. If night time work is approved,signaling and flagges shall conform to WAC296-155-305. Night time work to take place between_____________and ______________.)8. All Flagger and Downstream tapers shall be 50'-100'.LEGEND28" TRAFFIC CONESIGN LOCATIONTRAFFIC FLOWWORK VEHICLE/FLASHING LIGHTSRIGHT OF WAYWORK AREACHEVRONARROW BOARDFLAGGERUNIFORMEDPOLICE OFFICERPOLICESTOPPOLEMINIMUM TAPER LENGTH=L (FT.)LANEWIDTH101112207075802510511512530150165180352052252454027029532045475495540POSTED SPEED (MPH)505005506005555060566060-66072065--78070--840TEMPORARY TRAFFIC CONTROL PLANPuget Sound EnergyTraffic Control Supervisor:Gregory HarwoodCard No. ES2 000299Card Exp. 09/30/2027gregory.harwood@pse.com(425)424-642511 111111STOPFLAGGER STOPFLAGGER FLAGGER FORDRIVEWAY CONTROLSTOPFLAGGER FLAGGERS TO BE PLACED AT EACHDRIVEWAY WITHIN THE WORK AREAWORK AREA ONLYMORRIS AVE S S 7TH STMOSES LN SSHATTUCK AVE S1212 12121212WHITWORTH LN S ALLEYP04ANEWP04REPLACEONLYONLY111111 17 20 181811 11 11 S 7TH ST405 S 7th St Renton WA 98057 USAW20-1ROADWORKAHEADBEPREPAREDTOSTOPW3-4X'≥X'≥W20-1ROADWORKAHEADBEPREPAREDTOSTOPW3-4X'≥X'≥W20-1ROADWORKAHEADW20-4ONE LANEROADAHEADX'≥X'≥W20-7AX'≥STOP STOP W20-1ROADWORKAHEADW20-4ONE LANEROADAHEADX'≥X'≥X'≥ W20-7A W20-1ROADWORKAHEADBEPREPAREDTOSTOPW3-4X'≥X'≥W20-7AX'≥W20-1ROAD WORK AHEAD W20-4ONE LANEROADAHEADX'≥X'≥STO PRESIDENT(S) WILL BE INFORMED OFTEMPORARY DRIVEWAY CLOSURETHE CREW SHALL CEASEWORK AND ESCORT PEDESTRIANSAROUND/THRU WORK AREAFROM TO TOW AWAY AREA PHONE 684-5444 NAME OF FIRM XXX-XXX-XXXX NO PARKINGPLACE SIGNS BOTHSIDES OF WORK AREAP04BREMOVEProject Address:PagePSEPUGETSOUNDENERGYDesigner:Job #REVYURIY BASHTOVOY425-424-6425yuriy.bashtovoy@pse.com2 OF 14S 7TH ST CORRIDOR IMPROVEMENTS RENTON, WA 980571 1196436811/06/2024Notes:1. All signs and spacing to conform to theMUTCD and City of RENTON standards.2. All sidewalks, driveways, exits and egressesshall be completely clear unless otherwise indicated,if indicated use ADA compliant channelization.3. Channelizing devices are 28" traffic cones.Use traffic drums (barrels) with steady burningType C lights on all State State Routes and Hwys.4. Sign size can be a minimum of 36" x 36" andshall not obstruct pedestrian access.5. Crew is required to leave a minimum of 10' fortraveling lane width.6. Alert affected residents and businesses.7. Work to take place during approved work hours asper jurisdictional requirements. (Generally between 9a.m. and 4 p.m. on non-arterials and from 9 a.m. to 3p.m. on arterials. If night time work is approved,signaling and flagges shall conform to WAC296-155-305. Night time work to take place between_____________and ______________.)8. All Flagger and Downstream tapers shall be 50'-100'.LEGEND28" TRAFFIC CONESIGN LOCATIONTRAFFIC FLOWWORK VEHICLE/FLASHING LIGHTSRIGHT OF WAYWORK AREACHEVRONARROW BOARDFLAGGERUNIFORMEDPOLICE OFFICERPOLICESTOPPOLEMINIMUM TAPER LENGTH=L (FT.)LANEWIDTH101112207075802510511512530150165180352052252454027029532045475495540POSTED SPEED (MPH)505005506005555060566060-66072065--78070--840TEMPORARY TRAFFIC CONTROL PLANPuget Sound EnergyTraffic Control Supervisor:Gregory HarwoodCard No. ES2 000299Card Exp. 09/30/2027gregory.harwood@pse.com(425)424-64250'60'30'NSIGN SPACINGMPH60/6545/5535/403025"X"1000'500'350'200'100'CHANNELIZATIONDEVICE SPACINGMPH55/7035/4525/30TAPER403020TANGENT80604011 11 11 11 STO P FLAGGER STOP FLAGGER FLAGGER FORDRIVEWAY CONTROLSTOP FLAGGER FLAGGERS TO BE PLACED AT EACHDRIVEWAY WITHIN THE WORK AREAWORK AREA ONLYMORRIS AVE S S 7TH STMOSES LN SSHATTUCK AVE S1212 12121212WHITWORTH LN S ALLEY TALBOT RD SONLYONLY1111 111720 1818 11 11 11 S 7TH ST405 S 7th St Renton WA 98057 USAW20-1ROADWORKAHEADX'≥W20-1ROADWORKAHEADW20-4ONE LANEROADAHEADX'≥X'≥W20-7AX'≥STO P W20-1ROADWORKAHEADBEPREPAREDTOSTOPW3-4X'≥X'≥X'≥ W20-7A W20-1ROADWORKAHEADBEPREPAREDTOSTOPW3-4X'≥X'≥W20-7AX'≥W20-1ROAD WORK AHEAD W20-4ONE LANEROADAHEADX'≥X'≥STOPRESIDENT(S) WILL BE INFORMED OFTEMPORARY DRIVEWAY CLOSURETHE CREW SHALL CEASEWORK AND ESCORT PEDESTRIANSAROUND/THRU WORK AREAFROM TO TOW AWAY AREA PHONE 684-5444 NAME OF FIRM XXX-XXX-XXXX NO PARKINGPLACE SIGNS BOTHSIDES OF WORK AREAP06REPLACEW20-7A X'≥W20-1ROADWORKAHEADX'≥P14Project Address:PagePSEPUGETSOUNDENERGYDesigner:Job #REVYURIY BASHTOVOY425-424-6425yuriy.bashtovoy@pse.com3 OF 14S 7TH ST CORRIDOR IMPROVEMENTS RENTON, WA 980571 1196436811/06/2024Notes:1. All signs and spacing to conform to theMUTCD and City of RENTON standards.2. All sidewalks, driveways, exits and egressesshall be completely clear unless otherwise indicated,if indicated use ADA compliant channelization.3. Channelizing devices are 28" traffic cones.Use traffic drums (barrels) with steady burningType C lights on all State State Routes and Hwys.4. Sign size can be a minimum of 36" x 36" andshall not obstruct pedestrian access.5. Crew is required to leave a minimum of 10' fortraveling lane width.6. Alert affected residents and businesses.7. Work to take place during approved work hours asper jurisdictional requirements. (Generally between 9a.m. and 4 p.m. on non-arterials and from 9 a.m. to 3p.m. on arterials. If night time work is approved,signaling and flagges shall conform to WAC296-155-305. Night time work to take place between_____________and ______________.)8. All Flagger and Downstream tapers shall be 50'-100'.LEGEND28" TRAFFIC CONESIGN LOCATIONTRAFFIC FLOWWORK VEHICLE/FLASHING LIGHTSRIGHT OF WAYWORK AREACHEVRONARROW BOARDFLAGGERUNIFORMEDPOLICE OFFICERPOLICESTOPPOLEMINIMUM TAPER LENGTH=L (FT.)LANEWIDTH101112207075802510511512530150165180352052252454027029532045475495540POSTED SPEED (MPH)505005506005555060566060-66072065--78070--840TEMPORARY TRAFFIC CONTROL PLANPuget Sound EnergyTraffic Control Supervisor:Gregory HarwoodCard No. ES2 000299Card Exp. 09/30/2027gregory.harwood@pse.com(425)424-64250'60'30'NSIGN SPACINGMPH60/6545/5535/403025"X"1000'500'350'200'100'CHANNELIZATIONDEVICE SPACINGMPH55/7035/4525/30TAPER403020TANGENT80604011 11 11 11 STO P FLAGGER STOP FLAGGER FLAGGER FORDRIVEWAY CONTROLSTOP FLAGGER FLAGGERS TO BE PLACED AT EACHDRIVEWAY WITHIN THE WORK AREAWORK AREA ONLYMORRIS AVE S S 7TH STTALBOT RD S 121212181110BU R N E T T A V S 14var.stop END OF ROADALLEY TALBOT RD S1818 11 11 11 S 7TH STW20-1ROADWORKAHEADW20-4ONE LANEROADAHEADX'≥X'≥X'≥W20-7ASTOP W20-1ROADWORKAHEADBEPREPAREDTOSTOPW3-4X'≥X'≥W20-1ROADWORKAHEADW20-4ONE LANEROADAHEADX'≥X'≥W20-7AX'≥W20-1ROAD WORK AHEAD W20-4ONE LANEROADAHEADX'≥X'≥STOP RESIDENT(S) WILL BE INFORMED OFTEMPORARY DRIVEWAY CLOSURETHE CREW SHALL CEASEWORK AND ESCORT PEDESTRIANSAROUND/THRU WORK AREAFROM TOTOW AWAY AREAPHONE 684-5444NAME OF FIRM XXX-XXX-XXXXNO PARKINGPLACE SIGNS BOTHSIDES OF WORK AREAW20-7AX'≥P1412W20-1 ROADWORKAHEADW20-1ROADWORKAHEADSTOP Project Address:PagePSEPUGETSOUNDENERGYDesigner:Job #REVYURIY BASHTOVOY425-424-6425yuriy.bashtovoy@pse.com4 OF 14S 7TH ST CORRIDOR IMPROVEMENTS RENTON, WA 980571 1196436811/06/2024Notes:1. All signs and spacing to conform to theMUTCD and City of RENTON standards.2. All sidewalks, driveways, exits and egressesshall be completely clear unless otherwise indicated,if indicated use ADA compliant channelization.3. Channelizing devices are 28" traffic cones.Use traffic drums (barrels) with steady burningType C lights on all State State Routes and Hwys.4. Sign size can be a minimum of 36" x 36" andshall not obstruct pedestrian access.5. Crew is required to leave a minimum of 10' fortraveling lane width.6. Alert affected residents and businesses.7. Work to take place during approved work hours asper jurisdictional requirements. (Generally between 9a.m. and 4 p.m. on non-arterials and from 9 a.m. to 3p.m. on arterials. If night time work is approved,signaling and flagges shall conform to WAC296-155-305. Night time work to take place between_____________and ______________.)8. All Flagger and Downstream tapers shall be 50'-100'.LEGEND28" TRAFFIC CONESIGN LOCATIONTRAFFIC FLOWWORK VEHICLE/FLASHING LIGHTSRIGHT OF WAYWORK AREACHEVRONARROW BOARDFLAGGERUNIFORMEDPOLICE OFFICERPOLICESTOPPOLEMINIMUM TAPER LENGTH=L (FT.)LANEWIDTH101112207075802510511512530150165180352052252454027029532045475495540POSTED SPEED (MPH)505005506005555060566060-66072065--78070--840TEMPORARY TRAFFIC CONTROL PLANPuget Sound EnergyTraffic Control Supervisor:Gregory HarwoodCard No. ES2 000299Card Exp. 09/30/2027gregory.harwood@pse.com(425)424-64250'60'30'NSIGN SPACINGMPH60/6545/5535/403025"X"1000'500'350'200'100'CHANNELIZATIONDEVICE SPACINGMPH55/7035/4525/30TAPER403020TANGENT80604011 11 11 11 STO P FLAGGER STOP FLAGGER FLAGGER FORDRIVEWAY CONTROLSTOP FLAGGER FLAGGERS TO BE PLACED AT EACHDRIVEWAY WITHIN THE WORK AREAWORK AREA ONLYMORRIS AVE S TALBOT RD S12121212 620 S 7th St Renton WA 98057 USA181110BU R N E T T A V S 14var.stop END OF ROADALLEY TALBOT RD SP08REPLACEP10REPLACE181811 11 11 S 7TH STSTOP STOP STOP STO P 18 18 STOP W20-1ROADWORKAHEADBEPREPAREDTOSTOPW3-4X'≥ X'≥ X'≥ W2 0 - 7 A W20-1ROADWORKAHEADBEPREPAREDTOSTOPW3-4X'≥X'≥X'≥ W20-7A W20-1ROAD WORK AHEAD W20-4ONE LANE ROADAHEADX'≥X'≥X'≥W20-7AW20-1ROADWORKAHEAD BEPREPAREDTOSTOPW3-4X'≥X'≥X'≥W20-7AW20-1ROADWORKAHEADW20-4ONE LANEROADAHEADX'≥X'≥X'≥W20-7AW20-1ROADWORKAHEADW20-4ONE LANEROADAHEADX'≥X'≥X'≥W20-7ARESIDENT(S) WILL BE INFORMED OFTEMPORARY DRIVEWAY CLOSURETHE CREW SHALL CEASEWORK AND ESCORT PEDESTRIANSAROUND/THRU WORK AREAFROM TO TOW AWAY AREA PHONE 684-5444 NAME OF FIRM XXX-XXX-XXXX NO PARKINGPLACE SIGNS BOTHSIDES OF WORK AREAProject Address:PagePSEPUGETSOUNDENERGYDesigner:Job #REVYURIY BASHTOVOY425-424-6425yuriy.bashtovoy@pse.com5 OF 14S 7TH ST CORRIDOR IMPROVEMENTS RENTON, WA 980571 1196436811/06/2024Notes:1. All signs and spacing to conform to theMUTCD and City of RENTON standards.2. All sidewalks, driveways, exits and egressesshall be completely clear unless otherwise indicated,if indicated use ADA compliant channelization.3. Channelizing devices are 28" traffic cones.Use traffic drums (barrels) with steady burningType C lights on all State State Routes and Hwys.4. Sign size can be a minimum of 36" x 36" andshall not obstruct pedestrian access.5. Crew is required to leave a minimum of 10' fortraveling lane width.6. Alert affected residents and businesses.7. Work to take place during approved work hours asper jurisdictional requirements. (Generally between 9a.m. and 4 p.m. on non-arterials and from 9 a.m. to 3p.m. on arterials. If night time work is approved,signaling and flagges shall conform to WAC296-155-305. Night time work to take place between_____________and ______________.)8. All Flagger and Downstream tapers shall be 50'-100'.LEGEND28" TRAFFIC CONESIGN LOCATIONTRAFFIC FLOWWORK VEHICLE/FLASHING LIGHTSRIGHT OF WAYWORK AREACHEVRONARROW BOARDFLAGGERUNIFORMEDPOLICE OFFICERPOLICESTOPPOLEMINIMUM TAPER LENGTH=L (FT.)LANEWIDTH101112207075802510511512530150165180352052252454027029532045475495540POSTED SPEED (MPH)505005506005555060566060-66072065--78070--840TEMPORARY TRAFFIC CONTROL PLANPuget Sound EnergyTraffic Control Supervisor:Gregory HarwoodCard No. ES2 000299Card Exp. 09/30/2027gregory.harwood@pse.com(425)424-64250'60'30'NSIGN SPACINGMPH60/6545/5535/403025"X"1000'500'350'200'100'CHANNELIZATIONDEVICE SPACINGMPH55/7035/4525/30TAPER403020TANGENT80604011 11 11 11 STO P FLAGGER STOP FLAGGER FLAGGER FORDRIVEWAY CONTROLSTOP FLAGGER FLAGGERS TO BE PLACED AT EACHDRIVEWAY WITHIN THE WORK AREAWORK AREA ONLYMORRIS AVE S TALBOT RD S1212 1212620 S 7th St Renton WA 98057 USA181110BU R N E T T A V S 14var.stop END OF ROADALLEY TALBOT RD SNEW181811 11 11 S 7TH STSTOP STOP STO P STO P W20-1ROADWORKAHEADBEPREPAREDTOSTOPW3-4X'≥ X'≥ X'≥ W2 0 - 7 A W20-1ROADWORKAHEADBEPREPAREDTOSTOPW3-4X'≥X'≥X'≥ W20-7A W20-1ROAD WORK AHEAD BEPREPARE D TOSTOP W3-4X'≥X'≥X'≥W20-7AW20-1ROADWORKAHEAD BEPREPAREDTOSTOPW3-4X'≥X'≥X'≥W20-7AW20-4ONE LANEROADAHEADX'≥X'≥X'≥W20-7AW20-1ROADWORKAHEADTHE CREW SHALL CEASEWORK AND ESCORT PEDESTRIANSAROUND/THRU WORK AREARESIDENT(S) WILL BE INFORMED OFTEMPORARY DRIVEWAY CLOSUREPEDESTRIAN AND BIKE DIVERSIONFOR SIDEWALK OR WALKWAYCLOSURES SEE PAGE 7.P10A S 7TH STW20-1ROADWORKAHEADBEPREPAREDTOSTOPW3-4X'≥X'≥X'≥W20-7A Project Address:PagePSEPUGETSOUNDENERGYDesigner:Job #REVYURIY BASHTOVOY425-424-6425yuriy.bashtovoy@pse.com6 OF 14S 7TH ST CORRIDOR IMPROVEMENTS RENTON, WA 980571 1196436811/06/2024Notes:1. All signs and spacing to conform to theMUTCD and City of RENTON standards.2. All sidewalks, driveways, exits and egressesshall be completely clear unless otherwise indicated,if indicated use ADA compliant channelization.3. Channelizing devices are 28" traffic cones.Use traffic drums (barrels) with steady burningType C lights on all State State Routes and Hwys.4. Sign size can be a minimum of 36" x 36" andshall not obstruct pedestrian access.5. Crew is required to leave a minimum of 10' fortraveling lane width.6. Alert affected residents and businesses.7. Work to take place during approved work hours asper jurisdictional requirements. (Generally between 9a.m. and 4 p.m. on non-arterials and from 9 a.m. to 3p.m. on arterials. If night time work is approved,signaling and flagges shall conform to WAC296-155-305. Night time work to take place between_____________and ______________.)8. All Flagger and Downstream tapers shall be 50'-100'.LEGEND28" TRAFFIC CONESIGN LOCATIONTRAFFIC FLOWWORK VEHICLE/FLASHING LIGHTSRIGHT OF WAYWORK AREACHEVRONARROW BOARDFLAGGERUNIFORMEDPOLICE OFFICERPOLICESTOPPOLEMINIMUM TAPER LENGTH=L (FT.)LANEWIDTH101112207075802510511512530150165180352052252454027029532045475495540POSTED SPEED (MPH)505005506005555060566060-66072065--78070--840TEMPORARY TRAFFIC CONTROL PLANPuget Sound EnergyTraffic Control Supervisor:Gregory HarwoodCard No. ES2 000299Card Exp. 09/30/2027gregory.harwood@pse.com(425)424-64250'60'30'NSIGN SPACINGMPH60/6545/5535/403025"X"1000'500'350'200'100'CHANNELIZATIONDEVICE SPACINGMPH55/7035/4525/30TAPER403020TANGENT80604011 11 11 11 STO P FLAGGER STOP FLAGGER FLAGGER FORDRIVEWAY CONTROLSTOP FLAGGER FLAGGERS TO BE PLACED AT EACHDRIVEWAY WITHIN THE WORK AREAWORK AREA ONLYMORRIS AVE S TALBOT RD S1212 1212181110BU R N E T T A V S 14var.stop END OF ROADALLEY TALBOT RD SP11REPLACE181811 11 11 S 7TH STSTO P STOP STOP STO P W20-1ROADWORKAHEADBEPREPAREDTOSTOPW3-4X'≥ X'≥ X'≥ W2 0 - 7 A W20-1ROADWORKAHEADW20-4ONE LANEROADAHEADX'≥X'≥X'≥ W20-7A W20-1ROAD WORK AHEAD BEPREPAR E D TO STOP W3-4X'≥X'≥X'≥W20-7AW20-1ROADWORKAHEAD W20-4ONE LANEROADAHEADX'≥X'≥X'≥W20-7ABEPREPAREDTOSTOPW3-4X'≥X'≥X'≥W20-7AW20-1ROADWORKAHEADTHE CREW SHALL CEASEWORK AND ESCORT PEDESTRIANSAROUND/THRU WORK AREARESIDENT(S) WILL BE INFORMED OFTEMPORARY DRIVEWAY CLOSUREP10APEDESTRIAN AND BIKE DIVERSIONFOR SIDEWALK OR WALKWAYCLOSURES SEE PAGE 14.Project Address:PagePSEPUGETSOUNDENERGYDesigner:Job #REVYURIY BASHTOVOY425-424-6425yuriy.bashtovoy@pse.com7 OF 14S 7TH ST CORRIDOR IMPROVEMENTS RENTON, WA 980571 1196436811/06/2024Notes:1. All signs and spacing to conform to theMUTCD and City of RENTON standards.2. All sidewalks, driveways, exits and egressesshall be completely clear unless otherwise indicated,if indicated use ADA compliant channelization.3. Channelizing devices are 28" traffic cones.Use traffic drums (barrels) with steady burningType C lights on all State State Routes and Hwys.4. Sign size can be a minimum of 36" x 36" andshall not obstruct pedestrian access.5. Crew is required to leave a minimum of 10' fortraveling lane width.6. Alert affected residents and businesses.7. Work to take place during approved work hours asper jurisdictional requirements. (Generally between 9a.m. and 4 p.m. on non-arterials and from 9 a.m. to 3p.m. on arterials. If night time work is approved,signaling and flagges shall conform to WAC296-155-305. Night time work to take place between_____________and ______________.)8. All Flagger and Downstream tapers shall be 50'-100'.LEGEND28" TRAFFIC CONESIGN LOCATIONTRAFFIC FLOWWORK VEHICLE/FLASHING LIGHTSRIGHT OF WAYWORK AREACHEVRONARROW BOARDFLAGGERUNIFORMEDPOLICE OFFICERPOLICESTOPPOLEMINIMUM TAPER LENGTH=L (FT.)LANEWIDTH101112207075802510511512530150165180352052252454027029532045475495540POSTED SPEED (MPH)505005506005555060566060-66072065--78070--840TEMPORARY TRAFFIC CONTROL PLANPuget Sound EnergyTraffic Control Supervisor:Gregory HarwoodCard No. ES2 000299Card Exp. 09/30/2027gregory.harwood@pse.com(425)424-64250'60'30'NSIGN SPACINGMPH60/6545/5535/403025"X"1000'500'350'200'100'CHANNELIZATIONDEVICE SPACINGMPH55/7035/4525/30TAPER403020TANGENT80604011 111111STOPFLAGGER STOPFLAGGER FLAGGER FORDRIVEWAY CONTROLSTOPFLAGGER FLAGGERS TO BE PLACED AT EACHDRIVEWAY WITHIN THE WORK AREAWORK AREA ONLYMORRIS AVE S TALBOT RD S12121212 620 S 7th St Renton WA 98057 USA181110BU R N E T T A V S 14var.stop END OF ROADALLEY TALBOT RD SP09REPLACE181811 11 11 S 7TH STSTOP STO P STOP W20-1ROADWORKAHEADBEPREPAREDTOSTOPW3-4X'≥ X'≥ X'≥ W2 0 - 7 A W20-1ROADWORKAHEADBEPREPAREDTOSTOPW3-4X'≥X'≥X'≥ W20-7A W20-1ROAD WORK AHEAD BEPREPAR E D TO STOP W3-4X'≥X'≥X'≥W20-7AW20-1ROADWORKAHEAD BEPREPAREDTOSTOPW3-4X'≥X'≥X'≥W20-7ABEPREPAREDTOSTOPW3-4X'≥X'≥X'≥W20-7AW4-119W20-1ROADWORKAHEADW20-1ROADWORKAHEADRIGHT LANECLOSEDAHEADW20-5RW4-2RX'≥X'≥RESIDENT(S) WILL BE INFORMED OFTEMPORARY DRIVEWAY CLOSURETHE CREW SHALL CEASEWORK AND ESCORT PEDESTRIANSAROUND/THRU WORK AREAPEDESTRIAN AND BIKE DIVERSIONFOR SIDEWALK OR WALKWAYCLOSURES SEE PAGE 14.Project Address:PagePSEPUGETSOUNDENERGYDesigner:Job #REVYURIY BASHTOVOY425-424-6425yuriy.bashtovoy@pse.com8 OF 14S 7TH ST CORRIDOR IMPROVEMENTS RENTON, WA 980571 1196436811/06/2024Notes:1. All signs and spacing to conform to theMUTCD and City of RENTON standards.2. All sidewalks, driveways, exits and egressesshall be completely clear unless otherwise indicated,if indicated use ADA compliant channelization.3. Channelizing devices are 28" traffic cones.Use traffic drums (barrels) with steady burningType C lights on all State State Routes and Hwys.4. Sign size can be a minimum of 36" x 36" andshall not obstruct pedestrian access.5. Crew is required to leave a minimum of 10' fortraveling lane width.6. Alert affected residents and businesses.7. Work to take place during approved work hours asper jurisdictional requirements. (Generally between 9a.m. and 4 p.m. on non-arterials and from 9 a.m. to 3p.m. on arterials. If night time work is approved,signaling and flagges shall conform to WAC296-155-305. Night time work to take place between_____________and ______________.)8. All Flagger and Downstream tapers shall be 50'-100'.LEGEND28" TRAFFIC CONESIGN LOCATIONTRAFFIC FLOWWORK VEHICLE/FLASHING LIGHTSRIGHT OF WAYWORK AREACHEVRONARROW BOARDFLAGGERUNIFORMEDPOLICE OFFICERPOLICESTOPPOLEMINIMUM TAPER LENGTH=L (FT.)LANEWIDTH101112207075802510511512530150165180352052252454027029532045475495540POSTED SPEED (MPH)505005506005555060566060-66072065--78070--840TEMPORARY TRAFFIC CONTROL PLANPuget Sound EnergyTraffic Control Supervisor:Gregory HarwoodCard No. ES2 000299Card Exp. 09/30/2027gregory.harwood@pse.com(425)424-64250'60'30'NSIGN SPACINGMPH60/6545/5535/403025"X"1000'500'350'200'100'CHANNELIZATIONDEVICE SPACINGMPH55/7035/4525/30TAPER403020TANGENT80604011 111111STOPFLAGGER STOPFLAGGER FLAGGER FORDRIVEWAY CONTROLSTOPFLAGGER FLAGGERS TO BE PLACED AT EACHDRIVEWAY WITHIN THE WORK AREAWORK AREA ONLYMORRIS AVE S TALBOT RD S12121212 620 S 7th St Renton WA 98057 USA181110BU R N E T T A V S 14var.stop END OF ROADALLEY TALBOT RD SP09REPLACE181811 11 11 S 7TH STSTOP STOP STO P W20-1ROADWORKAHEADBEPREPAREDTOSTOPW3-4X'≥ X'≥ X'≥ W2 0 - 7 A W20-1ROADWORKAHEADBEPREPAREDTOSTOPW3-4X'≥X'≥X'≥ W20-7A W20-1ROAD WORK AHEAD BEPREPARE D TO STOP W3-4X'≥X'≥X'≥W20-7AW20-1ROADWORKAHEAD BEPREPAREDTOSTOPW3-4X'≥X'≥X'≥W20-7ABEPREPAREDTOSTOPW3-4X'≥X'≥X'≥W20-7AW4-119W20-1ROADWORKAHEADW20-1ROADWORKAHEADRIGHT LANECLOSEDAHEADW20-5RW4-2RX'≥X'≥RESIDENT(S) WILL BE INFORMED OFTEMPORARY DRIVEWAY CLOSURETHE CREW SHALL CEASEWORK AND ESCORT PEDESTRIANSAROUND/THRU WORK AREAPEDESTRIAN AND BIKE DIVERSIONFOR SIDEWALK OR WALKWAYCLOSURES SEE PAGE 14.Project Address:PagePSEPUGETSOUNDENERGYDesigner:Job #REVYURIY BASHTOVOY425-424-6425yuriy.bashtovoy@pse.com9 OF 14S 7TH ST CORRIDOR IMPROVEMENTS RENTON, WA 980571 1196436811/06/2024Notes:1. All signs and spacing to conform to theMUTCD and City of RENTON standards.2. All sidewalks, driveways, exits and egressesshall be completely clear unless otherwise indicated,if indicated use ADA compliant channelization.3. Channelizing devices are 28" traffic cones.Use traffic drums (barrels) with steady burningType C lights on all State State Routes and Hwys.4. Sign size can be a minimum of 36" x 36" andshall not obstruct pedestrian access.5. Crew is required to leave a minimum of 10' fortraveling lane width.6. Alert affected residents and businesses.7. Work to take place during approved work hours asper jurisdictional requirements. (Generally between 9a.m. and 4 p.m. on non-arterials and from 9 a.m. to 3p.m. on arterials. If night time work is approved,signaling and flagges shall conform to WAC296-155-305. Night time work to take place between_____________and ______________.)8. All Flagger and Downstream tapers shall be 50'-100'.LEGEND28" TRAFFIC CONESIGN LOCATIONTRAFFIC FLOWWORK VEHICLE/FLASHING LIGHTSRIGHT OF WAYWORK AREACHEVRONARROW BOARDFLAGGERUNIFORMEDPOLICE OFFICERPOLICESTOPPOLEMINIMUM TAPER LENGTH=L (FT.)LANEWIDTH101112207075802510511512530150165180352052252454027029532045475495540POSTED SPEED (MPH)505005506005555060566060-66072065--78070--840TEMPORARY TRAFFIC CONTROL PLANPuget Sound EnergyTraffic Control Supervisor:Gregory HarwoodCard No. ES2 000299Card Exp. 09/30/2027gregory.harwood@pse.com(425)424-64250'60'30'NSIGN SPACINGMPH60/6545/5535/403025"X"1000'500'350'200'100'CHANNELIZATIONDEVICE SPACINGMPH55/7035/4525/30TAPER403020TANGENT80604011 111111STOPFLAGGER STOPFLAGGER FLAGGER FORDRIVEWAY CONTROLSTOPFLAGGER FLAGGERS TO BE PLACED AT EACHDRIVEWAY WITHIN THE WORK AREAWORK AREA ONLYTALBOT RD S620 S 7th St Renton WA 98057 USA1811 10BURNETT AV S 14var .stopEND OF ROADALLEY TALBOT RD S11 11 11P11A TALBOT RD S S 6TH ST S 7TH ST S 7TH ST19191818 CONETOPPER 1818S/WCLOSEDR9-9S/W CLOSEDR9-9W20-1ROADWORKAHEADX'≥X'≥X'≥RIGHT LANECLOSEDAHEADW20-5RW1-4LW20-1ROADWORKAHEADW20-1 ROADWORKAHEADW20-1ROADWORKAHEADW20-1 ROADWORKAHEADX'≥ X'≥ RESIDENT(S) WILL BE INFORMED OF TEMPORARY DRIVEWAY CLOSURE THE CREW SHALL CEASE WORK AND ESCORT PEDESTRIANS AROUND/THRU WORK AREA PEDESTRIAN AND BIKE DIVERSION FOR SIDEWALK OR WALKWAY CLOSURES SEE PAGE 14.FROMTOTOW AWAY AREAPHONE 684-5444NAME OF FIRM XXX-XXX-XXXXNO PARKINGPLACE SIGNS BOTH SIDES OF WORK AREA W20-1ROAD WORK AHEADX'≥X'≥W1-4RW4-1190'60'30' N SIGN SPACING MPH 60/65 45/55 35/40 30 25 "X" 1000' 500' 350' 200' 100' CHANNELIZATION DEVICE SPACING MPH 55/70 35/45 25/30 TAPER 40 30 20 TANGENT 80 60 40 Project Address: Page PSE PUGETSOUNDENERGY Designer: Job # REV YURIY BASHTOVOY 425-424-6425 yuriy.bashtovoy@pse.com 10 OF 14S 7TH ST CORRIDOR IMPROVEMENTS RENTON, WA 98057 1 11964368 11/06/2024 MINIMUM TAPER LENGTH=L (FT.) LANE WIDTH 10 11 12 20 70 75 80 25 105 115 125 30 150 165 180 35 205 225 245 40 270 295 320 45 475 495 540 POSTED SPEED (MPH) 50 500 550 600 55 550 605 660 60 - 660 720 65 - - 780 70 - - 840 LEGEND 28" TRAFFIC CONE SIGN LOCATION TRAFFIC FLOW WORK VEHICLE/ FLASHING LIGHTS RIGHT OF WAY WORK AREA CHEVRON ARROW BOARD FLAGGER UNIFORMED POLICE OFFICERPOLICE STOP POLE TEMPORARY TRAFFIC CONTROL PLAN Puget Sound Energy Traffic Control Supervisor: Gregory Harwood Card No. ES2 000299Card Exp. 09/30/2027gregory.harwood@pse.com(425)424-6425 Notes: 1. All signs and spacing to conform to the MUTCD and City of RENTON standards. 2. All sidewalks, driveways, exits and egresses shall be completely clear unless otherwise indicated, if indicated use ADA compliant channelization. 3. Channelizing devices are 28" traffic cones. Use traffic drums (barrels) with steady burning Type C lights on all State State Routes and Hwys. 4. Sign size can be a minimum of 36" x 36" and shall not obstruct pedestrian access. 5. Crew is required to leave a minimum of 10' for traveling lane width. 6. Alert affected residents and businesses. 7. Work to take place during approved work hours as per jurisdictional requirements. (Generally between 9 a.m. and 4 p.m. on non-arterials and from 9 a.m. to 3 p.m. on arterials. If night time work is approved, signaling and flagges shall conform to WAC 296-155-305. Night time work to take place between _____________and ______________.) 8. All Flagger and Downstream tapers shall be 50'-100'. ONLYTALBOT RD S620 S 7th St Renton WA 98057 USA1811 10BURNETT AV S 14var .stopEND OF ROAD TALBOT RD S11 11 11P13B S 7TH ST S 7TH ST ONLYONLYON L Y ONL Y T A L BO T R D S S GRA D Y W A Y ARRW-BRD ROADWORKAHEADW20-1RIGHT LANECLOSEDAHEADW20-5RW4-2LROADWORKAHEADW20-1 350'111111111111111 1 1 1 1 1 1 1 SIDE W A L K CLOS E D R9-9DETO U R M4-9bROAD WORK AHEA D W20-1RIGHT L A NE CLOSE D AHEA D W20-5RW4-2LW20-1ROADWORKAHEADW20-1ROADWORKAHEADW20-1 ROADWORKAHEADX'≥ X'≥ X'≥X'≥ X ' ≥X'≥SIDEWALKCLOSEDR9-9PEDESTRIAN AND BIKE DIVERSION FOR SIDEWALK OR WALKWAY CLOSURES SEE PAGE 14. 1818 0'60'30' N SIGN SPACING MPH 60/65 45/55 35/40 30 25 "X" 1000' 500' 350' 200' 100' CHANNELIZATION DEVICE SPACING MPH 55/70 35/45 25/30 TAPER 40 30 20 TANGENT 80 60 40 Project Address: Page PSE PUGETSOUNDENERGY Designer: Job # REV YURIY BASHTOVOY 425-424-6425 yuriy.bashtovoy@pse.com 11 OF 14S 7TH ST CORRIDOR IMPROVEMENTS RENTON, WA 98057 1 11964368 11/06/2024 MINIMUM TAPER LENGTH=L (FT.) LANE WIDTH 10 11 12 20 70 75 80 25 105 115 125 30 150 165 180 35 205 225 245 40 270 295 320 45 475 495 540 POSTED SPEED (MPH) 50 500 550 600 55 550 605 660 60 - 660 720 65 - - 780 70 - - 840 LEGEND 28" TRAFFIC CONE SIGN LOCATION TRAFFIC FLOW WORK VEHICLE/ FLASHING LIGHTS RIGHT OF WAY WORK AREA CHEVRON ARROW BOARD FLAGGER UNIFORMED POLICE OFFICERPOLICE STOP POLE TEMPORARY TRAFFIC CONTROL PLAN Puget Sound Energy Traffic Control Supervisor: Gregory Harwood Card No. ES2 000299Card Exp. 09/30/2027gregory.harwood@pse.com(425)424-6425 Notes: 1. All signs and spacing to conform to the MUTCD and City of RENTON standards. 2. All sidewalks, driveways, exits and egresses shall be completely clear unless otherwise indicated, if indicated use ADA compliant channelization. 3. Channelizing devices are 28" traffic cones. Use traffic drums (barrels) with steady burning Type C lights on all State State Routes and Hwys. 4. Sign size can be a minimum of 36" x 36" and shall not obstruct pedestrian access. 5. Crew is required to leave a minimum of 10' for traveling lane width. 6. Alert affected residents and businesses. 7. Work to take place during approved work hours as per jurisdictional requirements. (Generally between 9 a.m. and 4 p.m. on non-arterials and from 9 a.m. to 3 p.m. on arterials. If night time work is approved, signaling and flagges shall conform to WAC 296-155-305. Night time work to take place between _____________and ______________.) 8. All Flagger and Downstream tapers shall be 50'-100'. ONLYTALBOT RD S620 S 7th St Renton WA 98057 USA1811 10BURNETT AV S 14var .stopEND OF ROADALLEY TALBOT RD S11 11 11TALBOT RD S S 7TH ST S GR A D Y W A Y P13A1919STOP STOP STOP STOP STOP W20-1ROADWORKAHEADW20-4ONE LANEROADAHEADX'≥X'≥X'≥W20-7AUSE MAXIMUM AVAILABLE SPACE FOR SIGNS W20-7A X'≥W20-1ROADWORKAHEADBEPREPAREDTOSTOPW3-4X'≥X'≥X'≥W20-7A1818 THE CREW SHALL CEASE WORK AND ESCORT PEDESTRIANS AROUND/THRU WORK AREA PEDESTRIAN AND BIKE DIVERSION FOR SIDEWALK OR WALKWAY CLOSURES SEE PAGE 14.FROMTOTOW AWAY AREAPHONE 684-5444NAME OF FIRM XXX-XXX-XXXXNO PARKINGPLACE SIGNS BOTH SIDES OF WORK AREA 0'60'30' N SIGN SPACING MPH 60/65 45/55 35/40 30 25 "X" 1000' 500' 350' 200' 100' CHANNELIZATION DEVICE SPACING MPH 55/70 35/45 25/30 TAPER 40 30 20 TANGENT 80 60 40 Project Address: Page PSE PUGETSOUNDENERGY Designer: Job # REV YURIY BASHTOVOY 425-424-6425 yuriy.bashtovoy@pse.com 12 OF 14S 7TH ST CORRIDOR IMPROVEMENTS RENTON, WA 98057 1 11964368 11/06/2024 MINIMUM TAPER LENGTH=L (FT.) LANE WIDTH 10 11 12 20 70 75 80 25 105 115 125 30 150 165 180 35 205 225 245 40 270 295 320 45 475 495 540 POSTED SPEED (MPH) 50 500 550 600 55 550 605 660 60 - 660 720 65 - - 780 70 - - 840 LEGEND 28" TRAFFIC CONE SIGN LOCATION TRAFFIC FLOW WORK VEHICLE/ FLASHING LIGHTS RIGHT OF WAY WORK AREA CHEVRON ARROW BOARD FLAGGER UNIFORMED POLICE OFFICERPOLICE STOP POLE TEMPORARY TRAFFIC CONTROL PLAN Puget Sound Energy Traffic Control Supervisor: Gregory Harwood Card No. ES2 000299Card Exp. 09/30/2027gregory.harwood@pse.com(425)424-6425 Notes: 1. All signs and spacing to conform to the MUTCD and City of RENTON standards. 2. All sidewalks, driveways, exits and egresses shall be completely clear unless otherwise indicated, if indicated use ADA compliant channelization. 3. Channelizing devices are 28" traffic cones. Use traffic drums (barrels) with steady burning Type C lights on all State State Routes and Hwys. 4. Sign size can be a minimum of 36" x 36" and shall not obstruct pedestrian access. 5. Crew is required to leave a minimum of 10' for traveling lane width. 6. Alert affected residents and businesses. 7. Work to take place during approved work hours as per jurisdictional requirements. (Generally between 9 a.m. and 4 p.m. on non-arterials and from 9 a.m. to 3 p.m. on arterials. If night time work is approved, signaling and flagges shall conform to WAC 296-155-305. Night time work to take place between _____________and ______________.) 8. All Flagger and Downstream tapers shall be 50'-100'. ONLYTALBOT RD S620 S 7th St Renton WA 98057 USA 18 11 BURNETT AV S 14var .stopEND OF ROADALLEY TALBOT RD S11 11 11TALBOT RD S S 7TH ST S GR A D Y W A Y P1319191818 STOP W20-1ROADWORKAHEAD W20-4ONE LANEROADAHEADX'≥X'≥X'≥W20-7AW20-1 ROAD WORK AHEADW20-1ROADWORKAHEADW20-1ROADWORKAHEADBEPREPAREDTOSTOPW3-4X'≥X'≥X'≥W20-7ATHE CREW SHALL CEASE WORK AND ESCORT PEDESTRIANS AROUND/THRU WORK AREA PEDESTRIAN AND BIKE DIVERSION FOR SIDEWALK OR WALKWAY CLOSURES SEE PAGE 14.FROMTOTOW AWAY AREAPHONE 684-5444NAME OF FIRM XXX-XXX-XXXXNO PARKINGPLACE SIGNS BOTH SIDES OF WORK AREA W20-7A 0'60'30' N SIGN SPACING MPH 60/65 45/55 35/40 30 25 "X" 1000' 500' 350' 200' 100' CHANNELIZATION DEVICE SPACING MPH 55/70 35/45 25/30 TAPER 40 30 20 TANGENT 80 60 40 Project Address: Page PSE PUGETSOUNDENERGY Designer: Job # REV YURIY BASHTOVOY 425-424-6425 yuriy.bashtovoy@pse.com 13 OF 14S 7TH ST CORRIDOR IMPROVEMENTS RENTON, WA 98057 1 11964368 11/06/2024 MINIMUM TAPER LENGTH=L (FT.) LANE WIDTH 10 11 12 20 70 75 80 25 105 115 125 30 150 165 180 35 205 225 245 40 270 295 320 45 475 495 540 POSTED SPEED (MPH) 50 500 550 600 55 550 605 660 60 - 660 720 65 - - 780 70 - - 840 LEGEND 28" TRAFFIC CONE SIGN LOCATION TRAFFIC FLOW WORK VEHICLE/ FLASHING LIGHTS RIGHT OF WAY WORK AREA CHEVRON ARROW BOARD FLAGGER UNIFORMED POLICE OFFICERPOLICE STOP POLE TEMPORARY TRAFFIC CONTROL PLAN Puget Sound Energy Traffic Control Supervisor: Gregory Harwood Card No. ES2 000299Card Exp. 09/30/2027gregory.harwood@pse.com(425)424-6425 Notes: 1. All signs and spacing to conform to the MUTCD and City of RENTON standards. 2. All sidewalks, driveways, exits and egresses shall be completely clear unless otherwise indicated, if indicated use ADA compliant channelization. 3. Channelizing devices are 28" traffic cones. Use traffic drums (barrels) with steady burning Type C lights on all State State Routes and Hwys. 4. Sign size can be a minimum of 36" x 36" and shall not obstruct pedestrian access. 5. Crew is required to leave a minimum of 10' for traveling lane width. 6. Alert affected residents and businesses. 7. Work to take place during approved work hours as per jurisdictional requirements. (Generally between 9 a.m. and 4 p.m. on non-arterials and from 9 a.m. to 3 p.m. on arterials. If night time work is approved, signaling and flagges shall conform to WAC 296-155-305. Night time work to take place between _____________and ______________.) 8. All Flagger and Downstream tapers shall be 50'-100'. 5'8'Cold Mix5' x 8'steel plate3/4"-1" thick,non-skidmaterialcold mixcold mixnon-skid plateSIDEWALKCLOSEDSIDEWALKCLOSEDCrew will create pedestrian/wheelchair ADA compliant rampsand assist pedestrians aroundwork area.TYPICAL CONFIGURATIONFOR PEDESTRIAN AND BIKEDIVERSION FOR SIDEWALK ORWALKWAY CLOSURES (OUTSIDE)5' MiniumumCrew will create pedestrian/wheelchair compliant rampsand assist pedestrians aroundwork area.Add additional conesfor safetySIDEWALKCLOSEDR9-9SIDEWALKCLOSEDR9-9 TYPICAL CONFIGURATIONFOR PEDESTRIAN AND BIKEDIVERSION FOR SIDEWALK ORWALKWAY CLOSURES (INSIDE)curb fa ceLevel Landingfrom Sidewalk to curb edgenon-skid materialLevel Landingfrom Ramp ontostreet surfacenon-skid materialRamp Surface ADA compliant (12:1 slope)non-skid material (crew will assist)Stabilized material forfull ramp support12:1 slope4' M in imum 6" Min ADA compliantdetectable stripProject Address:PagePSEPUGETSOUNDENERGYDesigner:Job #REVYURIY BASHTOVOY425-424-6425yuriy.bashtovoy@pse.com14 OF 14S 7TH ST CORRIDOR IMPROVEMENTS RENTON, WA 980571 1196436811/06/2024LEGEND28" TRAFFIC CONESIGN LOCATIONTRAFFIC FLOWWORK VEHICLE/FLASHING LIGHTSRIGHT OF WAYWORK AREACHEVRONARROW BOARDFLAGGERUNIFORMEDPOLICE OFFICERPOLICESTOPPOLEMINIMUM TAPER LENGTH=L (FT.)LANEWIDTH101112207075802510511512530150165180352052252454027029532045475495540POSTED SPEED (MPH)505005506005555060566060-66072065--78070--840TEMPORARY TRAFFIC CONTROL PLANPuget Sound EnergyTraffic Control Supervisor:Gregory HarwoodCard No. ES2 000299Card Exp. 09/30/2027gregory.harwood@pse.com(425)424-6425SIGN SPACINGMPH60/6545/5535/403025"X"1000'500'350'200'100'CHANNELIZATIONDEVICE SPACINGMPH55/7035/4525/30TAPER403020TANGENT806040 N Vicinity Map 101169535 R1UNIVERSAL CIRCUIT MAP SCALE: NONE ARE TO BE INSTALLED, CROSS SECTION DETAILS OF THE TYPICAL EROSION STRUCTURES, & SPECIAL REQUIREMENTS FOR WORK IN SENSITIVE AREAS.) EROSION & SEDIMENT CONTROL REQUIREMENTS NOTES DETAILING WHERE EROSION OR SEDIMENT CONTROL STRUCTURES (LOCAL JURISDICTIONS MAY HAVE ADDITIONAL REQUIREMENTS INCLUDING 0150.3200 TECHNIQUES FOR TEMPORARY EROSION & SEDIMENT CONTROL EROSION & SEDIMENT CONTROL SHALL BE PER PSE STANDARD PRACTICE & ANY ADDITIONAL LOCAL JURISDICTION REQUIREMENTS. FOREMAN (CHECK BOX WHEN COMPLETED) PSE Equipment LOCKED/SECURED & Work Area left in CLEAN/SAFE Condition. Grid, Cable, and Switch numbers INSTALLED & VERIFIED. Field Changes RED-LINED on As-built. Indicate correct FUSE SIZE on As-built & VERIFY proper PHASE. Foreman's Signature _______________________________________________ Print Name ___________________________________ Date ______________ Material VERIFIED and CHANGES noted on Paperwork. Total PRIMARY Cable noted on As-built. Company ID#'s RECORDED in correct location on As-built. Deviations noted on the As-built and their reason. I certify that the work performed meets PSE's standards and procedures and that all quality requirements are met. SCALE: NONE OVERHEAD CIRCUIT MAP No No No Yes Yes Yes "Flagging Required" "Outages Required" "Locates Required" S 7TH ST CORRIDOR IMPROVEMENTS POLE RELOCATION PSE CAPITAL PROJECT GENERAL SPECIFICATIONS Scope of Work PSE project to relocate existing utility poles to the north to accommodate new sidewalk facilities. General -All work is to be completed per PSE Standards & Practices. Copies of all PSE Standards are available upon request. -Work sites shall be kept clear of debris and all construction materials; equipment and packing shall be removed daily. -Return all unused and removed poles, transformers and hardware to PSE, storeroom. All copper shall be coiled and returned the day it is removed from the poles. Remove all unused pins and insulators. -Return all streetlights, area lights and floodlights to Sumner yard. Preconstruction - Notify appropriate city, County or DOT authorities 48 to 72 hours, or as required by permitting agency, in advance of starting work in Right-of-way involving a Permit. - All system switching shall be approved by System Operations (425-882-4652) a minimum of 48 hours in advance. - Notify customers of all outages 48 hours in advance. Work Drawings & Documents - Field design changes shall be approved by PSE Project Manager or Engineer. - Mark all field changes, equipment ID numbers and Underground cable information in red on Foreman's copy of worksketch. - Return one Foreman's copy of worksketch to Project Manager at completion of job. - When permits are required, a copy shall be available on work site at all times. Safety - Refer to PSE standards 6275.3000 and 6275.6000 for system ground requirements. - Refer to PSE standards 6275.9050 for personal protective grounding requirements. - Refer to PSE standards 6275.9150 for vehicle grounding and barricading requirements. - Proper line clearances shall be taken at the beginning, and released at the end, of each work day, or as otherwise instructed by the System Operator. - Provide signs, barricades, and traffic control in conformance with permit regulations. - Utilize flagging and other vehicle traffic control as necessary and in conformance with local traffic regulations. - Maintain traffic flow as required by permitting agency. Erosion & Sediment Control - Refer to PSE standards 0150.3200 for minimum requirements. - Comply with all requirements of permitting agency. - Installed erosion & sediment devices shall be maintained until vegetation has been re-established or disturbed soil has been otherwise permanently stabilized. Joint Facilities - Coordinate with Communication Companies for transfers. OVERHEAD CONSTRUCTION Poles & Structures - Poles are to be installed or relocated as staked. Unless otherwise noted, all pole location measurements are from the center of the pole. - All new poles set shall be the class indicated on the sketch, or better. Do not set a lower class pole than specified. - Install ground plate assembly on all new poles. Install Switch Ground Assembly per standard specification 6014.1000 at new gang operated switch locations. - Install grid numbers on all new and existing poles as shown on sketch. - Straighten existing poles as indicated or as necessary. - Treat all field-drilled poles with copper napthenate wood preservative. - Remove old poles after communication companies have transferred off and return to PSE storeroom. Fill and crown pole holes and restore area similar to adjacent landscaping. Conductors & Equipment - Transfer all overhead and underground primary, secondary and service conductors and guys to new poles set, unless otherwise indicated on this sketch. - Transfer existing transformers to new poles unless otherwise indicated on this sketch. - Use stirrups to connect all overhead and underground primary taps, and all transformers. Install at all sites being worked within the scope of the project where they are currently missing. - Use 397 AAC and Ampact connectors for all bare conductor feeder jumpers and 600 amp switch jumpers. Install tree wire conductor for jumpers on all poles that are double deadended with tree wire. - Apply grit inhibitor on all Ampact, stirrup, and dead-end connections. - Connect primary taps and transformers to same phase as existing unless otherwise shown on the drawing. - All neutral connections to be made with solid compression connectors. Connect all pole grounds to common neutral. - Use Load-interrupter cutouts (with arc shields) on all primary overhead and underground taps with fused protection above 40T. - Install Wildlife Protectors on all transformers. UNDERGROUND CONSTRUCTION Excavation -Trenching outside of the Right-of-way shall be of sufficient depth to provide a minimum of 36” of cover for primary conductors and 24” of cover for secondary conductors. -Road crossings and all trenches within the Right-of-way shall be of sufficient depth to provide a minimum of 36” of cover for all conductors or as required by the permitting Agency. -All conductors/conduits shall have a minimum of 3” of bed and 3” of clean sand cover. -No rocks larger than 6” shall be included in backfill. -Backfill in road crossings and within the Right-of-way shall be compacted to 95% density or as required by the permitting Agency. -Restore all excavated areas to original condition. - If four or more six inch conduits are installed in a trench, fluidized thermal backfill (FTB) shall be installed around the conduits to a depth of six inches above and to the sides of the conduit, and two inches underneath, per PSE Standard 6790.0140. Vaults & Handholes - Refer to PSE standard 6775.0040 “Vault and Handhole Installation” - Vaults shall be placed level and 2” above final grade in landscaped areas and flush with final grade when placed in hard surface areas. - A minimum 6” bed of 5/8” crushed rock shall be placed under all vaults. - All conduit entrances shall be grouted. Conductors & Conduit - Refer to PSE standard 6800.6000 “PVC Conduit Installation”. - Unless splices are called for, or otherwise noted or approved, conduit risers shall be plumbed directly to road crossing conduits. - Install insulating caps on all unused primary bushings. - All “spare” conduits shall be capped at each end. Owner / Developer Contact Info officeATTN: City of Renton 1055 S Grady Way Renton, WA 98057 Keith Woolley (425) 430-7318PHONE CABLE TV 11964368 101169535 N/A 583075500 N/A N/A N/A N/A N/A 108152096 PROJECT PHASE PWR NOTIF#ORDER# Superior UG Expense Removal OH Expense 593255189 N/A UG Expense OH Expense E-Mail: Cell Phone: Project Manager Contact Information: Manager:Dustin Weller (206) 379-4347 Dustin.Weller@pse.com UTILITIES CONTACT PHONE# COUNTY 1/4 SEC U-MAP NO (POWER) OP MAP Emer Sect Gas Wk Ctr POWER WK CTR PLAT MAP JOINT FACILITIES ARRANGEMENTS DRAWN BY CHECKED BY APPROVED BY FOREMAN #1 FOREMAN #2 MAPPING INCIDENT MAOP Gas Order Elect Order SCALE PAGE ENGR - POWER ENGR - GAS FUNCTION PROJECT MGR PERMITREAL ESTATE/EASEMENT 2 1 REV# 3 DATE DESCRIPTIONBY CONTACT PHONE NO DATE OH CKT MAP CIRCUIT NOUG CKT MAP Dustin Weller (206) 379-4347 11/01/24 David Santiago (425) 738-8705 11/01/24 N/A N/A N/A Ally Melin (360) 402-4754 11/01/24 REQUIRED RENTON S 7TH ST CORRIDOR IMPROVEMENTS Pole Relocation S 7th ST, Renton, WA 98057 N/A N/A N/A 101169535 AS NOTED 1 / 5 KING N/A N/A CSPFEPI S18 T23 R05E N/A N/A 2305E072 2305E076 2305E072 GRA-15 N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A THIS SKETCH NOT TO BE RELIED UPON FOR EXACT LOCATION OF EXISTING FACILITIES CALL 811 TWO BUSINESS DAYS BEFORE YOU DIG For contacts below dial 1-888-CALL PSE (225-5773) LEGEND CONDUIT RISER OVERHEAD TRANSFORMER JUNCTION VAULT/JUNCTION BOX NEW CONDUCTOR AND OR TRENCH LINE DISCONNECT - FUSED PULL VAULT OR SPLICE VAULT EXISTING POLE DOWN GUY DISCONNECT - UNFUSED NEW POLE PADMOUNT TRANSFORMER SECONDARY HANDHOLE EXISTING CONDUCTOR TO BE REMOVED OR ABANDONED STREET LIGHT TOTAL UNDERGROUND TRANSFORMER ENERGY CUSTOMER DEMAND POINT OR OR OR OVERHEAD JUMPER CONNECTION JOBSITE JOBSITE JOBSITE POTELCO 11/01/24 ALLY M.REDESIGN AT S7TH & BURNETT AVE VTrofimenko 11/5/24 David Santiago (425) 738-8705 11/05/24 103+00 104+00 105+00 106+00 107+00 108+00 603-639 408 631 633 637 405 628 632 & 634 642 415 626 TRANSFER EXISTING SECONDARY TRANSFER EXISTING #2ACSRTRANSFER EXISTING SECONDARY TREE TO REMAIN TREE REMOVAL NEEDED TRANSFER EXISTING #2ACSR AND SECONDARY WHITWORTH LN SWHITWORTH LN SMOSES LN SMORRIS AVE SS 7TH ST 636 5'x5' EASEMENT REQUIRED TRANSFER EXISTING SECONDARY TRANSFER EXISTING SECONDARY TRANSFER EXISTING #2ACSR AND SECONDARY 423 TRANSFER EXISTING #2ACSR TRANSFER EXISTING SECONDARY TRANSFER EXISTING SECONDARY TRANSFER EXISTING #2ACSR NOTE: DO NOT TRANSFER EXISTING. REPLACE WITH NEW DUE TO EXPOSED WIRE TRANSFER EXISTING SECONDARY INSTALL NEW 4/0 TRIPLEX SECONDARY UTILITIES CONTACT PHONE# COUNTY 1/4 SEC U-MAP NO (POWER) OP MAP Emer Sect Gas Wk Ctr POWER WK CTR PLAT MAP JOINT FACILITIES ARRANGEMENTS DRAWN BY CHECKED BY APPROVED BY FOREMAN #1 FOREMAN #2 MAPPING INCIDENT MAOP Gas Order Elect Order SCALE PAGE ENGR - POWER ENGR - GAS FUNCTION PROJECT MGR PERMITREAL ESTATE/EASEMENT 2 1 REV# 3 DATE DESCRIPTIONBY CONTACT PHONE NO DATE OH CKT MAP CIRCUIT NOUG CKT MAP Dustin Weller (206) 379-4347 11/01/24 David Santiago (425) 738-8705 11/01/24 N/A N/A N/A Ally Melin (360) 402-4754 11/01/24 REQUIRED RENTON S 7TH ST CORRIDOR IMPROVEMENTS Pole Relocation S 7th ST, Renton, WA 98057 N/A N/A N/A 101169535 AS NOTED 2 / 5 KING N/A N/A CSPFEPI S18 T23 R05E N/A N/A 2305E072 2305E076 2305E072 GRA-15 N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A SITE PLAN SCALE: 1"=20' POLE TABLE (NEW) Site # Pole Data Grid #Height Class Year Remarks / Location Ref. P02 317597-165925 45 1 P04 317597-165946 45 1 P04A 317597-165941 35 1 P06 317594-165954 45 1 P08 317594-165965 50 1 POLE RETIREMENT TABLE TEMP TRANSFERS ST. LIGHT TRANSFERS SITE # POLE DATA POLE TEL TV FIBER TRAN RMVD ID NUMBER GRID #HEIGHT CLASS YEAR TOPPED RMVD P03 317595-165928 65 UNK 1946 SLAG6972 P04B 317594-165945 45 UNK 1965 SLAG6978 P06 317594-165954 45 UNK 1969 P08 317594-165965 45 2 1962 SLAG6977 New pole at site: Grid Number: kVA Rating: Foreman to redline the following information TRANSFORMER TRANSFER Company ID#: Primary phase connected to: Tested Secondary Voltage P04 317597-165946 100kVA Installed at site: Grid Number: kVA Rating: TRANSFORMER INSTALLATION (OH) Company ID#: Primary phase connected to: Tested Secondary Voltage Material ID#: Foreman to redline the following information P04 317597-165946 Removed at site: Grid Number: kVA Rating: Foreman to redline the following information TRANSFORMER REMOVAL Company ID#: Primary phase connected to: Tested Secondary Voltage P04B 317594-165945 10kVA MATCHLINESEE PAGE 3/3AA25kVA 6211250 SECONDARY CABLE & CONDUIT TABLE LOCATION CABLE Assumed Lot Corner CONDUIT ASBUILT INFORMATION SIZE LENGTH Design (ft) SIZE LENGTH Design (ft) BENDS Foreman - Complete FROM TO (1/0,4/0,350)to Meter(ft)(in)90°45°22°11°Actual Amount Installed (Conduit & Cable) SP1 P06 RE-ROUTE EXISTING SECONDARY CABLE UP NEW POLE SITE SPECIFIC NOTES: P02 (317597-165925) NEW - INSTALL NEW 45' CL1 POLE AS STAKED (PD451) 6010.1000 - INSTALL (1) INS 4" RIGID CLEVIS (INDNRC) 6015.1000 - INSTALL (1) 3/8" PRIMARY DOWN GUY WEST (GYD3SA) 6013.0100 - INSTALL (1) 3/8" NEUTRAL DOWN GUY WEST (GYD3SAN) 6013.0100 - INSTALL (1) 10" SINGLE HELIX ANCHOR WEST, L = 4' (ANDH1) 6012.1000 - TRANSFER EXISTING ST. LIGHT FROM P03 (SLAG6972) P04 (317597-165946) RELOCATE - INSTALL NEW 45' CL1 POLE AS STAKED (PD451) 6010.1000 - INSTALL (1) INS 4" RIGID CLEVIS (INDNRC) 6015.1000 - INSTALL DBL ST 9FT CROSS ARMS - INSTALL 12 kV 3-PHASE, TANGENT DE 2 ACSR (DE2315) 6033.1040 - INSTALL (1) 7/16" PRIMARY DOWN GUY WEST (GYD7SA) 6013.0100 - INSTALL (1) 3/8" NEUTRAL DOWN GUY WEST (GYD3SAN) 6013.0100 - INSTALL (1) 20" PLATE ANCHOR WEST, L=20' (ANDP20) 6012.1000 - INSTALL NEW 25kVA 120/240V TRANSFORMER (TRFNXF) 6025.1000 - TRANSFER EXISTING 100kVA 120/240V TRANSFORMER FROM OLD POLE - TRANSFER EXISTING ST. LIGHT FROM P04 (SLAG6978) - OLD POLE TO BE REMOVED P04A (317597-165941) NEW - INSTALL NEW 35' CL1 POLE AS STAKED (PS351) 6010.1100 - INSTALL NEW 4/0 SECONDARY TRIPLEX FROM THE EAST - INSTALL (1) INS 4" RIGID CLEVIS (INDNRC) 6015.1000 - TRANSFER EXISTING SERVICES TO HSE "636" AND "408" P06 (317594-165954) REPLACE - INSTALL NEW 45' CL1 POLE AS STAKED (PD451) 6010.1000 - INSTALL DBL 11FT WING ARMS - INSTALL 12 kV 3-PHASE, DBL WING #2 ACSR (TADW312) 6033.4020 - INSTALL (1) INS 4" RIGID CLEVIS (INDNRC) 6015.1000 - INSTALL (1) 3" RISER ASSEMBLIES (RIS3CSS) 6042.1000 - OLD POLE TO BE REMOVED SP1 - SPLICE ONTO EXISTING SECONDARY CABLE AND RE-ROUTE TO NEW POLE P06 P07 (317588-165963) EXISTING - EXISTING POLE TO REMAIN - INSTALL (1) 7/16" PRIMARY DOWN GUY SOUTH (GYD7SA) 6013.0100 - INSTALL (1) 3/8" NEUTRAL DOWN GUY SOUTH (GYD3SAN) 6013.0100 - INSTALL (1) 20" PLATE ANCHOR SOUTH, L=15' (ANDP20) 6012.1000 P08 (317594-165965) REPLACE - INSTALL NEW 50' CL1 POLE AS STAKED (PD501) 6010.1000 - INSTALL (1) DBL 11FT WING ARM GOING NORTH/SOUTH IN NORMAL POSITION - INSTALL (1) DBL 11FT WING ARM GOING EAST/WEST IN BUCK POSITION - INSTALL (2) 12 kV 3-PHASE, DBL DE WINGARM #2 ACSR (DDW312) 6033.4024 - INSTALL (1) 3/8" OH W/HELI GRIP SPAN GUY TO P07 (GYD3OW) 6013.0170 - TRANSFER EXISTING ST. LIGHT FROM P08 (SLAG6977) - TRANSFER EXISTING SERVICE TO "642" - OLD POLE TO BE REMOVED 2-23 2-302 2-23 2-24 2-24 2-302 2-23 WIRE REMOVAL TABLE Location Wire Size & Type Quantity Length (per conductor)RemarksFromTo P03 P04B SPAN GUY 1 164' P04B P06 SPAN GUY 1 94' TOTAL 258 FT (SPAN GUY). ACTUAL _________ FT (SPAN GUY) REMOVED 2-129 2-129 2-129 2-129 WIRE STRINGING PRIMARY & SECONDARY Location Pri Sec Wire Size & Type Quantity Length (Per conductor)Total ActualFromTo P04 P04A X 4/0 TRIPLEX 1 48 P04A "408"X 4/0 TRIPLEX 1 50 2-20A 2-20A 2-23 2-20A 2-20A TOTAL UNITS ON PAGE: 2-20Ax4 2-23x5 2-24x2 2-129x4 2-302x3 1-8ex1 101169535 R111/01/24 ALLY M.REDESIGN AT S7TH & BURNETT AVE SERVICE RELOCATIONS AND CONVERSIONS NAME AND ADDRESS Meter Number Old Point of Delivery New Point of Delivery Service Notes SEE PAGE 5 FOR FULL TABLE BREAKLINE +- 65' 2-23 2-302 1-8e 1 VTrofimenko 11/5/24 David Santiago (425) 738-8705 11/05/24 109+00 110+00 110+58 300+00 301+ 00 302+00401+00400+00 201+00201+63 623 627 629 633 629 621 633SMITHERS AVE SS 7TH ST BURNETT AVE STRANSFER EXISTING SECONDARY TRANSFER EXISTING 397.5 MCMAAC AND SECONDARYTREE TRIMMING NEEDED 423 BURNETT AVE S628 632 & 634 642 UTILITIES CONTACT PHONE# COUNTY 1/4 SEC U-MAP NO (POWER) OP MAP Emer Sect Gas Wk Ctr POWER WK CTR PLAT MAP JOINT FACILITIES ARRANGEMENTS DRAWN BY CHECKED BY APPROVED BY FOREMAN #1 FOREMAN #2 MAPPING INCIDENT MAOP Gas Order Elect Order SCALE PAGE ENGR - POWER ENGR - GAS FUNCTION PROJECT MGR PERMITREAL ESTATE/EASEMENT 2 1 REV# 3 DATE DESCRIPTIONBY CONTACT PHONE NO DATE OH CKT MAP CIRCUIT NOUG CKT MAP Dustin Weller (206) 379-4347 11/01/24 David Santiago (425) 738-8705 11/01/24 N/A N/A N/A Ally Melin (360) 402-4754 11/01/24 REQUIRED RENTON S 7TH ST CORRIDOR IMPROVEMENTS Pole Relocation S 7th ST, Renton, WA 98057 N/A N/A N/A 101169535 AS NOTED 3 / 5 KING N/A N/A CSPFEPI S18 T23 R05E N/A N/A 2305E072 2305E076 2305E072 GRA-15 N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A SITE PLAN SCALE: 1"=20' POLE RETIREMENT TABLE TEMP TRANSFERS ST. LIGHT TRANSFERS SITE # POLE DATA POLE TEL TV FIBER TRAN RMVD ID NUMBER GRID #HEIGHT CLASS YEAR TOPPED RMVD P09 317589-165987 35 3 2022 P10 317594-165977 40 UNK 1980 P11 317594-165989 50 UNK 1962 SLAG6976 Installed at site: Grid Number: kVA Rating: TRANSFORMER INSTALLATION (OH) Company ID#: Primary phase connected to: Tested Secondary Voltage Material ID#: Foreman to redline the following information P11 317594-165989Removed at site: Grid Number: kVA Rating: Foreman to redline the following information TRANSFORMER REMOVAL Company ID#: Primary phase connected to: Tested Secondary Voltage P11 317594-165989 25kVAMATCHLINESEE PAGE 2/3AA25kVA 6211250 Removed at site: Grid Number: kVA Rating: Foreman to redline the following information TRANSFORMER REMOVAL Company ID#: Primary phase connected to: Tested Secondary Voltage P10 317594-165977 15kVA WIRE STRINGING PRIMARY & SECONDARY Location Pri Sec Wire Size & Type Quantity Length (Per conductor)Total ActualFromTo P11 P09 X 397.5 MCMAAC 3 76 228 P09 P13B X 397.5 MCMAAC 3 106 318 P13B P13A X 397.5 MCMAAC 3 55 165 P13A P13 X 397.5 MCMAAC 3 82 246 P11 P09 X 4/0 TRIPLEX 1 76 76 P09 P13B X 4/0 TRIPLEX 1 106 106 P13B P13A X 4/0 TRIPLEX 1 55 55 P13A P13 X 4/0 TRIPLEX 1 82 82 2-20A 2-129 2-129 2-129 2-20A 2-20A TOTAL UNITS ON PAGE: 2-20Ax7 2-23x6 2-24x2 2-129x3 2-302x1 1-8ex1 SITE SPECIFIC NOTES: P09 (317589-165987) REPLACE - INSTALL NEW 50' CL1 POLE AS STAKED (PD501) 6010.1000 - INSTALL 12kV 3-PHASE SLACK DEADEND (EAST) (SSF312DE) 6033.5010 - INSTALL (2) DBL HD 9FT CROSS ARMS - INSTALL (1) 12 kV 3-PHASE, DBL-DBL DE 397 AAC (DDD3315) 6033.1052 - INSTALL (2) INS 4" RIGID CLEVIS (INDNRC) 6015.1000 - INSTALL (3) 7/16" PRIMARY DOWN GUY SOUTH (GYD7SA) 6013.0100 - INSTALL (1) 3/8" NEUTRAL DOWN GUY SOUTH (GYD3SAN) 6013.0100 - INSTALL (1) TRIPLE HELIX 1.5" ROD SOUTH, L=20' (ANDH3) 6012.1000 - INSTALL 3-PHASE TAP NORTH (LAT315) 6033.5100 - INSTALL LI C/O'S FUSE @ 100T (3412700) 6099.9999 - INSTALL SWITCH # X91891 P10 (317594-165977) REPLACE - INSTALL NEW 45' CL1 POLE AS STAKED (PD451) 6010.1000 - INSTALL (1) DBL 11FT WING ARM - INSTALL 12 kV 3-PHASE, DE DBL WING #2 ACSR (DEW313) 6033.4030 - INSTALL (1) INS 4" RIGID CLEVIS (INDNRC) 6015.1000 - INSTALL (4) 3/8" OH W/HELI GRIP SPAN GUY TO P10A - INSTALL NEW 25kVA 120/240V TRANSFORMER (TRFNXF) 6025.1000 - TRANSFER (3) SOLID BLADE SWITCHES (X2297) - OLD POLE TO BE REMOVED P10A (317596-165985) NEW - INSTALL NEW 45' CL2 POLE AS STAKED (PD452) 6010.1000 - INSTALL (1) 7/16" PRIMARY DOWN GUY EAST (GYD7SA) 6013.0100 - INSTALL (1) 3/8" NEUTRAL DOWN GUY EAST (GYD3SAN) 6013.0100 - INSTALL 20" PLATE ANCHOR EAST, L=15' (ANDP20) 6012.1000 SP2 - SPLICE ONTO EXISTING SECONDARY CABLE AND RE-ROUTE TO NEW POLE P11 P11 (317594-165989) REPLACE - INSTALL NEW 55' CL1 POLE AS STAKED (PD551) 6010.1000 - INSTALL (1) DBL 11FT WING ARMS - INSTALL (1) 12 kV 3-PHASE, DBL WING 397 AAC (TADW313) 6033.4022 - INSTALL (1) 7/16" PRIMARY DOWN GUY WEST (GYD7SA) 6013.0100 - INSTALL (1) 10" SINGLE HELIX ANCHOR WEST, L = 10' (ANDH1) 6012.1000 - INSTALL NEW 25kVA 120/240V TRANSFORMER (TRFNXF) 6025.1000 - TRANSFER EXISTING ST. LIGHT FROM P11 (SLAG6976) - INSTALL (1) 3" RISER ASSEMBLIES (RIS3CSS) 6042.1000 - OLD POLE TO BE REMOVED P13 (317587-166013) EXIST - EXISTING 45' POLE TO REMAIN - EXISTING LI C/0'S FUSE @ 65T TO REMAIN - EXISTING SWITCH #X803 TO REMAIN - EXISTING RISER ASSEMBLY TO REMAIN - INSTALL 12kV 3-PHASE SLACK SPAN 397 AAC (WEST) (SSF313) 6033.5010 - INSTALL (1) DBL HD 9FT CROSS ARMS - INSTALL (3) 7/16" PRIMARY DOWN GUY WEST (GYD7SA) 6013.0100 - INSTALL (1) 3/8" NEUTRAL DOWN GUY WEST (GYD3SAN) 6013.0100 - INSTALL (1) TRIPLE HELIX 1.5" ROD WEST, L=17' (ANDH3) 6012.1000 P13A (317590-166008) NEW - INSTALL NEW 45' CL2 POLE AS STAKED (PD452) 6010.1000 - INSTALL 12kV 3-PHASE SLACK DEADEND (NORTHEAST) (SSF312DE) 6033.5010 - INSTALL (2) DBL HD 9FT CROSS ARMS - INSTALL (1) 12 kV 3-PHASE, DBL-DBL DE 397 AAC (DDD3315) 6033.1052 - INSTALL (2) INS 4" RIGID CLEVIS (INDNRC) 6015.1000 - INSTALL (3) 7/16" PRIMARY DOWN GUY NORTHEAST (GYD7SA) 6013.0100 - INSTALL (1) 3/8" NEUTRAL DOWN GUY NORTHEAST (GYD3SAN) 6013.0100 - INSTALL (1) TRIPLE HELIX 1.5" ROD NORTHEAST, L=17' (ANDH3) 6012.1000 P13B (317590-166008) NEW - INSTALL NEW 50' CL2 POLE AS STAKED (PD502) 6010.1000 - INSTALL (1) DBL ST 9FT CROSS ARMS - INSTALL (1) 12 kV 3-Phase, DBL PIN 397 AAC (ANG313) 6033.1022 - INSTALL (1) INS 4" RIGID CLEVIS (INDNRC) 6015.1000 - INSTALL (3) 7/16" PRIMARY DOWN GUY SOUTHWEST (GYD7SA) 6013.0100 - INSTALL (1) 3/8" NEUTRAL DOWN GUY SOUTHWEST (GYD3SAN) 6013.0100 - INSTALL (1) TRIPLE HELIX 1.5" ROD SOUTHWEST=17' (ANDH3) 6012.1000 2-20A Installed at site: Grid Number: kVA Rating: TRANSFORMER INSTALLATION (OH) Company ID#: Primary phase connected to: Tested Secondary Voltage Material ID#: Foreman to redline the following information P10 317594-165977 25kVA 6211250 POLE TABLE (NEW) Site # Pole Data Grid #Height Class Year Remarks / Location Ref. P09 317589-165987 50 1 P10 317594-165977 45 1 P10A 317596-165985 45 2 P11 317594-165989 55 1 P13A 317590-166008 45 2 P13B 317588-166004 50 1 101169535 R111/01/24 ALLY M.REDESIGN AT S7TH & BURNETT AVE SERVICE RELOCATIONS AND CONVERSIONS NAME AND ADDRESS Meter Number Old Point of Delivery New Point of Delivery Service Notes SEE PAGE 5 FOR FULL TABLE 1 2-23 2-23 2-24 2-23 2-23 2-24 2-302 1-8e 2-23 2-23 2-20A 2-20A 2-20A WIRE REMOVAL TABLE Location Wire Size & Type Quantity Length (per conductor)RemarksFromTo P10 P11 #2 ACSR PRIMARY 3 141' P10 P11 4/0 TRIPLEX NEUTRAL 1 141' P11 P09 SPAN GUY 1 75' TOTAL 423 FT (#2 ACSR). ACTUAL _________ FT (#2 ACSR) REMOVED TOTAL 141 FT (4/0 TRIPLEX). ACTUAL _________ FT (4/0 TRIPLEX) REMOVED TOTAL 75 FT (SPAN GUY). ACTUAL _________ FT (SPAN GUY) REMOVED1 1 1 1 1 1 1 1 1 VTrofimenko 11/5/24 David Santiago (425) 738-8705 11/05/24 P13A (317590-166008) NEW - INSTALL NEW 45' CL2 POLE AS STAKED (PD452) 6010.1000 - INSTALL 12kV 3-PHASE SLACK DEADEND (NORTHEAST) (SSF312DE) 6033.5010 - INSTALL (2) DBL HD 9FT CROSS ARMS - INSTALL (1) 12 kV 3-PHASE, DBL-DBL DE 397 AAC (DDD3315) 6033.1052 - INSTALL (2) INS 4" RIGID CLEVIS (INDNRC) 6015.1000 - INSTALL (3) 7/16" PRIMARY DOWN GUY NORTHEAST (GYD7SA) 6013.0100 - INSTALL (1) 3/8" NEUTRAL DOWN GUY NORTHEAST (GYD3SAN) 6013.0100 - INSTALL (1) TRIPLE HELIX 1.5" ROD NORTHEAST, L=17' (ANDH3) 6012.1000 P13B (317588-166004) NEW - INSTALL NEW 50' CL2 POLE AS STAKED (PD502) 6010.1000 - INSTALL (1) DBL ST 9FT CROSS ARMS - INSTALL (1) 12 kV 3-Phase, DBL PIN 397 AAC (ANG313) 6033.1022 - INSTALL (1) INS 4" RIGID CLEVIS (INDNRC) 6015.1000 - INSTALL (3) 7/16" PRIMARY DOWN GUY SOUTHWEST (GYD7SA) 6013.0100 - INSTALL (1) 3/8" NEUTRAL DOWN GUY SOUTHWEST (GYD3SAN) 6013.0100 - INSTALL (1) TRIPLE HELIX 1.5" ROD SOUTHWEST=17' (ANDH3) 6012.1000 2-23 2-23 EXISTING DIRECT BURIED SECONDARY NEW DIRECT BURIED 4/0 SECONDARY TALBOT RD SSMITHERS AVE SEXISTING DIRECT BURIED SECONDARY S 7TH ST NEW DIRECT BURIED 4/0 SECONDARY UTILITIES CONTACT PHONE# COUNTY 1/4 SEC U-MAP NO (POWER) OP MAP Emer Sect Gas Wk Ctr POWER WK CTR PLAT MAP JOINT FACILITIES ARRANGEMENTS DRAWN BY CHECKED BY APPROVED BY FOREMAN #1 FOREMAN #2 MAPPING INCIDENT MAOP Gas Order Elect Order SCALE PAGE ENGR - POWER ENGR - GAS FUNCTION PROJECT MGR PERMITREAL ESTATE/EASEMENT 2 1 REV# 3 DATE DESCRIPTIONBY CONTACT PHONE NO DATE OH CKT MAP CIRCUIT NOUG CKT MAP Dustin Weller (206) 379-4347 11/01/24 David Santiago (425) 738-8705 11/01/24 N/A N/A N/A Ally Melin (360) 402-4754 11/01/24 REQUIRED RENTON S 7TH ST CORRIDOR IMPROVEMENTS Pole Relocation S 7th ST, Renton, WA 98057 N/A N/A N/A 101169535 AS NOTED 4 / 5 KING N/A N/A CSPFEPI S18 T23 R05E N/A N/A 2305E072 2305E076 2305E072 GRA-15 N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A SECONDARY CABLE DIAGRAM 2 NOT TO SCALE SECONDARY CABLE DIAGRAM 1 NOT TO SCALE SECONDARY CABLE & CONDUIT TABLE LOCATION CABLE Assumed Lot Corner CONDUIT ASBUILT INFORMATION SIZE LENGTH Design (ft) SIZE LENGTH Design (ft) BENDS Foreman - Complete FROM TO (1/0,4/0,350)to Meter(ft)(in)90°45°22°11°Actual Amount Installed (Conduit & Cable) SP1 P06 RE-ROUTE EXISTING SECONDARY CABLE UP NEW POLE SP2 P11 RE-ROUTE EXISTING SECONDARY CABLE UP NEW POLE 101169535 R111/01/24 ALLY M.REDESIGN AT S7TH & BURNETT AVE VTrofimenko 11/5/24 David Santiago (425) 738-8705 11/05/24 UTILITIES CONTACT PHONE# COUNTY 1/4 SEC U-MAP NO (POWER) OP MAP Emer Sect Gas Wk Ctr POWER WK CTR PLAT MAP JOINT FACILITIES ARRANGEMENTS DRAWN BY CHECKED BY APPROVED BY FOREMAN #1 FOREMAN #2 MAPPING INCIDENT MAOP Gas Order Elect Order SCALE PAGE ENGR - POWER ENGR - GAS FUNCTION PROJECT MGR PERMITREAL ESTATE/EASEMENT 2 1 REV# 3 DATE DESCRIPTIONBY CONTACT PHONE NO DATE OH CKT MAP CIRCUIT NOUG CKT MAP Dustin Weller (206) 379-4347 11/01/24 David Santiago (425) 738-8705 11/01/24 N/A N/A N/A Ally Melin (360) 402-4754 11/01/24 REQUIRED RENTON S 7TH ST CORRIDOR IMPROVEMENTS Pole Relocation S 7th ST, Renton, WA 98057 N/A N/A N/A 101169535 AS NOTED 5 / 5 KING N/A N/A CSPFEPI S18 T23 R05E N/A N/A 2305E072 2305E076 2305E072 GRA-15 N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A 101169535 R111/01/24 ALLY M.REDESIGN AT S7TH & BURNETT AVE SERVICE RELOCATIONS AND CONVERSIONS NAME AND ADDRESS Meter Number Old Point of Delivery New Point of Delivery Service Notes BANKERS AUTO REBUILD 317 S 7TH ST, Renton WA 98057 X150776024 P02A-P03-P01 P02A-P02-P01 POLE RELOCATION BANKERS AUTO REBUILD 405 S 7TH ST, Renton WA 98057 P157450620 P07 P07 POLE RELOCATION DOLL LEE-MCCLAIN 636 WHITWORTH LN S, RENTON WA 98057 X149115405 P04B P04-P04A POLE RELOCATION JAMES E BANKER INC 405 S 7TH ST, Renton WA 98057 X149102628 P07 P07 POLE RELOCATION JAMES E BANKER INC 405 S 7TH ST #HSE, Renton WA 98057 X149102643 P04B-P05 P04-P05 POLE RELOCATION JAMES E BANKER INC 405 S 7TH ST #202, Renton WA 98057 X149102657 P04B-P05 P04-P05 POLE RELOCATION LLOYD BELL 405 S 7TH ST #203, Renton WA 98057 X149121184 P04B-P05 P04-P05 POLE RELOCATION JAMES E BANKER INC 405 S 7TH ST #204, Renton WA 98057 X149102658 P04B-P05 P04-P05 POLE RELOCATION JAMES E BANKER INC 405 S 7TH ST #205, Renton WA 98057 X149121167 P04B-P05 P04-P05 POLE RELOCATION JESSICA COOPER 405 S 7TH ST #206, Renton WA 98057 X149121165 P04B-P05 P04-P05 POLE RELOCATION AMANDA MACK 405 S 7TH ST #207, Renton WA 98057 X149102660 P04B-P05 P04-P05 POLE RELOCATION TRACEY CARLIN 405 S 7TH ST #208, Renton WA 98057 X149102676 P04B-P05 P04-P05 POLE RELOCATION AARON TUCKER 405 S 7TH ST #209, RENTON WA 98057 X149102659 P04B-P05 P04-P05 POLE RELOCATION ANTHONY PARKER 405 S 7TH ST #301, Renton WA 98057 X149102595 P04B-P05 P04-P05 POLE RELOCATION JAMES E BANKER INC 405 S 7TH ST #302, Renton WA 98057 X149102596 P04B-P05 P04-P05 POLE RELOCATION SERENA REHDER 405 S 7TH ST #303, Renton WA 98057 X149102641 P04B-P05 P04-P05 POLE RELOCATION FRANK ANDERSON 405 S 7TH ST #304, Renton WA 98057 X149102644 P04B-P05 P04-P05 POLE RELOCATION RACHELLE LUCERO 405 S 7TH ST #305, Renton WA 98057 X149121151 P04B-P05 P04-P05 POLE RELOCATION JAMES E BANKER INC 405 S 7TH ST #306, Renton WA 98057 X149102675 P04B-P05 P04-P05 POLE RELOCATION JAMES E BANKER INC 405 S 7TH ST #307, Renton WA 98057 X149102673 P04B-P05 P04-P05 POLE RELOCATION JAMES E BANKER INC 405 S 7TH ST #308, Renton WA 98057 X149102642 P04B-P05 P04-P05 POLE RELOCATION JAMES E BANKER INC 405 S 7TH ST #309, Renton WA 98057 X149102593 P04B-P05 P04-P05 POLE RELOCATION CHRIS FOSTER 405 S 7TH ST #310, Renton WA 98057 X149102594 P04B-P05 P04-P05 POLE RELOCATION HORTENCIA MORAN ORANTES 408 S 7TH ST #1, Renton WA 98057 X149104803 P04B P04-P04A POLE RELOCATION IRENE ARIPES 408 S 7TH ST #2, Renton WA 98057 X149104801 P04B P04-P04A POLE RELOCATION JESUS PADILLA 408 S 7TH ST #3, Renton WA 98057 X149104804 P04B P04-P04A POLE RELOCATION UNOCCUPIED 415 S 7TH ST, Renton WA 98057 X155951544 P04-P06-H01 P04-P06-H01 POLE RELOCATION ROSS GONEDRIDGE 632 MORRIS AVE S, Renton WA 98057 X149106466 P10-P12 P10-P12 POLE RELOCATION ROSS GONEDRIDGE 634 MORRIS AVE S, Renton WA 98057 X149106465 P10-P12 P10-P12 POLE RELOCATION SERVICE RELOCATIONS AND CONVERSIONS NAME AND ADDRESS Meter Number Old Point of Delivery New Point of Delivery Service Notes M FAKHARZADEH 633 MORRIS AVE S #HSE, Renton WA 98057 X149121843 P08A-P08-P14 P08A-P08-P14 POLE RELOCATION JADEN VAN RIJN 633 MORRIS AVE S #1, Renton WA 98057 X149121844 P08A-P08-P14 P08A-P08-P14 POLE RELOCATION DAVID SCHMIDT 633 MORRIS AVE S #2, Renton WA 98057 X149121841 P08A-P08-P14 P08A-P08-P14 POLE RELOCATION BRIAN FRANCIS 633 MORRIS AVE S #3, Renton WA 98057 X149121842 P08A-P08-P14 P08A-P08-P14 POLE RELOCATION UNOCCUPIED 637 MORRIS AVE S Renton WA 98057 X150909926 P04-P06 P04-P06 POLE RELOCATION KEYSHAWN WILLIAMS 642 MORRIS AVE S, Renton WA 98057 X149106467 P08A-P08 P08A-P08 POLE RELOCATION ANTHONY LEE 629 SMITHERS AVE S #A, Renton WA 98057 X149102062 P10-P12 P10-P12 POLE RELOCATION RICHARD AU 629 SMITHERS AVE S #B, Renton WA 98057 X149102063 P10-P12 P10-P12 POLE RELOCATION ROBERT PRATHER 633 SMITHERS AVE S, Renton WA 98057 X149102061 P11 P11 POLE RELOCATION RENTON FAMILY HOUSING 633 BURNETT AVE S #HSE, Renton WA 98057 X149121453 P11-H02 P11-H02 POLE RELOCATION KAREN DONEY 633 BURNETT AVE S #101, Renton WA 98057 X149119433 P11-H02 P11-H02 POLE RELOCATION ELDA VASQUEZ 633 BURNETT AVE S #102, Renton WA 98057 X149119436 P11-H02 P11-H02 POLE RELOCATION SAMUEL MARITIM 633 BURNETT AVE S #201, Renton WA 98057 X149121459 P11-H02 P11-H02 POLE RELOCATION RATHANY CHANTHAVONGSA 633 BURNETT AVE S #202, Renton WA 98057 X149121458 P11-H02 P11-H02 POLE RELOCATION LAURA SANABRIA 633 BURNETT AVE S #301, Renton WA 98057 X149121457 P11-H02 P11-H02 POLE RELOCATION ANA GONZALEZ 633 BURNETT AVE S #302, Renton WA 98057 X149121460 P11-H02 P11-H02 POLE RELOCATION FRANCES KENSOK 627 WHITWORTH LN S, Renton WA 98057 X149119969 P02A P02A POLE RELOCATION COURTNEY WARREN 629 WHITWORTH LN S, Renton WA 98057 X149120002 P02A P02A POLE RELOCATION GRAHAM DAVIS 633 WHITWORTH LN S, Renton WA 98057 X149120004 P02A P02A POLE RELOCATION GAIL SCHUELER 635 WHITWORTH LN S, Renton WA 98057 X149120003 P02A P02A POLE RELOCATION MAKENNA O’MEARA 637 WHITWORTH LN S, Renton WA 98057 X149120025 P02A P02A POLE RELOCATION EDNA KING 639 WHITWORTH LN S, Renton WA 98057 X157745143 P02A P02A POLE RELOCATION MILENA MILIC 616 MORRIS AVE S, Renton WA 98057 X149106476 P08A P08A POLE RELOCATION JESSICA EAMES 620 MORRIS AVE S, Renton WA 98057 X149106475 P08A P08A POLE RELOCATION TOM DISBROW 621 MORRIS AVE S, Renton WA 98057 X149121883 P08A P08A POLE RELOCATION STACEY SNYDER 622 MORRIS AVE S, Renton WA 98057 X156245271 P08A P08A POLE RELOCATION STACEY SNYDER 622 MORRIS AVE S, Renton WA 98057 X156245272 P08A P08A POLE RELOCATION HOA NGUYEN 625 MORRIS AVE S, Renton WA 98057 X149121848 P08A P08A POLE RELOCATION SERVICE RELOCATIONS AND CONVERSIONS NAME AND ADDRESS Meter Number Old Point of Delivery New Point of Delivery Service Notes JACOB MEDLANG 628 MORRIS AVE S, Renton WA 98057 X149106468 P08A P08A POLE RELOCATION RENTON COIL SPRING COMPANY 423 S 7TH ST, Renton WA 98057 P154422966 P07 P07 POLE RELOCATION RENTON COIL SPRING COMPANY 423 S 7TH ST, Renton WA 98057 P144388246 P07 P07 POLE RELOCATION 1 VTrofimenko 11/5/24 David Santiago (425) 738-8705 11/05/24