Loading...
HomeMy WebLinkAbout25 Standard Details25. Standard Details 1 SE 172nd STREET GREEN STORMWATER INFRASTRUCTURE PROJECT SWP-27-4037 STANDARD DETAILS FACE OF CURB 6 112' ' 1/2" R. 1" R. 1:24 t TOP OF 112" R. ROADWAY I V ED T CEMENT CONCRETE TRAFFIC CURB AND GUTTER FACE OF ADJACENT CURB 6 1f2"-- FLUSH WITH GUTTER PAN AT SIDEWALK RAMP ENTRANCE 1:12 1:24 TOP OF 112" R. ROADWAY 1 DEPRESSED CURB SECTION AT SIDEWALK RAMPS w ' PREMOLDED JOINT FILLER E FULL -DEPTH EXPANSION JOINT 6" CEMENT CONCRETE 112" R. 1"R. SIDEWALK RAMP VARIES OR LANDING FROM ! 6"TOO S s" T 318" PREMOLDED JOINT FILLER CEMENT CONCRETE PEDESTRIAN CURB AT SIDEWALK RAMPS AND LANDINGS 6 112" ' FACE OF ADJACENT CURB SEE DEPRESSED CURB DETAIL THIS SHEET 114 TOP OF 1/2" R. ROADWAY 2" i T DEPRESSED CURB SECTION AT RESIDENTIAL DRIVEWAYS ONLY. FOR COMMERCIAL DRIVEWAYS SEE STD PLAN 104.2 1 P2' R. FACE OF ADJACENT CURB I GUTTER SURFACE u 6 112" 1" 1' R. FACE OF CURB 1" R. 8 114" 1" R. CEMENT CONCRETE i TRAFFIC CURB DEPRESSED CURB DETAIL AT RESIDENTIAL OR COMMERCIAL DRIVEWAYS, AND ALLEYS GENERAL NOTES: 1. See standard plans 102 and 101.1 for curb expansion and contraction joint spacing. 2. Expansion joint shall be full depth, 3/8" (in.) premolded joint filler. 3. For Depressed Monolithic Driveway Curb & Gutter Section, see Standard Plan 104.2 TOP OF ROADWAY STD. PLAN — 101 a PUBLIC WORKS CEMENT CONCRETE CURBSDEPARTMENT NOfE2 X3/8 -R X 5/8"D DUMMY JOINT I I I I 3/8- PREMOLDED JOINT FILLER (TYP) I F V— 5 _ PLAN VIEW FACEOF FRAME A GRATECURBI_S FRANE60RATE 6 1/2" IL• 13" 51 2" 1• ( I.OB') FRAMEANDGRATE-NOTndwosa 1/2" R. 1' jR MATCHROADWAY Iry DDRB AND DUTIERSID rlEh1 SLOPE TOP OFI 1R2EOE69 ROADWAY D' D D D D.. D.'.' ADJUSTMENT SECTION -NOTINCLUDED D' e' INCURSANDOUTIERSIDIIEM CATCH RUN -NOTDICL DED D •'••' - INCURSANDOUTTERSIDREM SECTION O GENERAL NOTES: 1. The Intent of this design Is to facilitate the removal' of a catch basin with minimal disturbance of the curb x .i- 2. The expansion joints of the - i . I. adjacentsidawalkshall be adjusted to be In line with these curb expansion joints. j I sI SEE NOTE2 CEMENTCONCREIE CURS AND ODTTER I ISO 2IC VIEW CEMENT CONCRETE CURB SM. PLAN — IMA PUBLIC WORKS PRO D: INSTALLATION AT DEPARTMENT CATCH BASINS ADA CEMENT SEE NOTE 31 CEMENT- DEPRESSED MONOLITHIC CONCRETE - CURB 8 CUTTER SIX -WALK j j (SEE DETAIL MS SHEET) TYPE C213 - ISOMETRIC VIEW COMMERCIAL, WITH BUFFER) NOTES 1. When a driveway width exceeds 15 feet, consbud a full depth expanslon joint with 3f8' Joint filler along the driveway lane lines see std. plan 102). Construct expansion joints parallel with the centerline as required at 15 maximum sparing when driveway Widths exceed 30'. 2. See std. plan 102 for sidewalk details. 3. Curb and gutter shown, other curb designs may be specified. See std. plan 101 for curb details. 4. Not used. 5. The engineer will design all driveways to Include elevations at all points marked with symbol "X'. All elevations are at the back of Curb top on uphill side. 6. Not used. 7. For Driveway Widths see DRIVEWAY STANDARDS See NOTE 10). The expansion joints (see end. plan 102) shall be spaced as shown In the corresponding leamViic New. 8. Slopes shall comply with sections 8303.21 or R303.2.2 or R303-2.3 of the Revised Draft Guidelines for Accessible Public Rigbtsaf=Way of Nove uba 23, 2005 (PROWAO). 9. Curb returns for any Type C -MAX Driveway maybe approved on a case-by-case basis, 10. STREET STANDARDS= Renton Municipal Code (RMC) Tide IV Development Regulators CHAPTER 6 STREET AND UTILITY STANDARDS Section 4.6-060 STREET STANDARDS DRIVEWAY STANDARDS = Renton Municipal Cade (RMC) Tice IV Development Regulations CHAPTER 4 CITY-WIDE PROPERTY DEVELOPMENT STANDARDS Section 4 -4 -ON PARKING, LOADING AND DRIVEWAY REGULATIONS aEE.C. coNTwtcnCN X} aro N.w tae b SEE DEFREMECC Dr1M on r z ew- Wit TOPOF1110MY NOTE, ORNE NYtalC.naEULmMB1IX1 ADM NOLtFMALO CURBDEPRESSEDMDNOLTTNIDpJRB 6 DUTfEfiOETAL FACE OF ADJACENT WF® DEPRESSED CURB DETAIL AT RESIDEMW. ORCORBBK.YAL DRIVEWAYS, AND ALIEN'S DdvelNay Example: TYPE C11 B R=Rlisd, d, C.CwwnwdAl 1NurtofLAIW. _---- MA)(x lwne Comm q a=b,(Pia tNSw;l 3an1F41e Buffer - PUBLIC WORE' CEMENT CONCRETE DRIVEWAY STD. PLAN - 104.2 DEPARTMENT ENTRANCES - NOTES AND DETAILS A11f'— // SEE 1piE 1 CE)gER R"'.S.V W. IM (v B CUMCVMI WfR31 SLOPE PYP.1 !SEE ND(E ]I 16' COIIIMCiiO O PO NI ''P IHIREBTB.PUIST PIAN VIEW I0 DVTERENCEWSLOPEl.4%- CEullWCRETESEIEWaIx v41E4 1>'Ei NOE 3)v lvu 3EE NOR3DYP1 6'MwtC!..=ETE 6.uw DEPRSSND'tflal DUTRR filofsvrix M'EV .SIO.:.0nrPI Rini I SECDON OA JfE 3TD. RAN 101, ID-RIT, aE16WMR WW M III \ pgryEWAY W' ITNE SLOPE 14lOPE 9NOWN FSAf.OfRAR01 __ _ \ IL 1. I ORMV/lYT 6. NN erN P • 6 _ SE NOB g®g PUBLIC WORKS DEPARTMENT TYPE RIB - ISOMETRIC VIEW RESIDENTIAL. WITH BUFFER( CEMEM CONCRETE CURIAGU TER INE NOR 31 CEMENT CONCRETE DRIVEWAY ENTRANCE - TYPE RIB For NOTES STD. PLAN 104.2 STD. PLAN - 104.3 PL[rCill Gregg Zimmerman, Public Warks Administrator 6AW t3EEWTEI SEE WYE II lavPAVED DRAEWAY REWIRED SY EYPMGLN Awi ILYF.1 SEE STO PUH 1111 CECDsE x la 1 6FE NOR E ls Z SEE 1piE 1 CE)gER R"'.S.V W. IM (v B CUMCVMI WfR31 SLOPE PYP.1 !SEE ND(E ]I 16' COIIIMCiiO O PO NI ''P IHIREBTB.PUIST PIAN VIEW I0 DVTERENCEWSLOPEl.4%- CEullWCRETESEIEWaIx v41E4 1>'Ei NOE 3)v lvu 3EE NOR3DYP1 6'MwtC!..=ETE 6.uw DEPRSSND'tflal DUTRR filofsvrix M'EV .SIO.:.0nrPI Rini I SECDON OA JfE 3TD. RAN 101, ID-RIT, aE16WMR WW M III \ pgryEWAY W' ITNE SLOPE 14lOPE 9NOWN FSAf.OfRAR01 __ _ \ IL 1. I ORMV/lYT 6. NN erN P • 6 _ SE NOB g®g PUBLIC WORKS DEPARTMENT TYPE RIB - ISOMETRIC VIEW RESIDENTIAL. WITH BUFFER( CEMEM CONCRETE CURIAGU TER INE NOR 31 CEMENT CONCRETE DRIVEWAY ENTRANCE - TYPE RIB For NOTES STD. PLAN 104.2 STD. PLAN - 104.3 PL[rCill Gregg Zimmerman, Public Warks Administrator ALL PAVEMENT MARKINGS SHALL CONFORM TO THE FOLLOWING WSDOT STD. PLANS, EXCEPT CROSSWALK MARKINGS AND STOP BARS SHALL BE PER CITY OF RENTON STD. PLANS 127 AND 128. WSDOT STD. PLANS NOT INCLUDED BELOW SHALL REQUIRE APPROVAL FROM CITY OF RENTON PUBLIC WORKS/TRANSPORTATION. M-3.10 LEFT TURN CHANNELIZATION M-3.20 LEFT-TURN CHANNELIZATION REDUCED TAPERS M-3.30 LEFT-TURN CHANNELIZATION TEE INTERSECTION AND BACK-TO-BACK TURN LANES M-3.40 TWO-WAY LEFT-TURN AND MEDIAN CHANNELIZATION M-3.50 DOUBLE LEFT TURN CHANNELIZATION M-5.10 RIGHT TURN CHANNELIZATION M-9.50 BICYCLE LANE SYMBOL LAYOUT M-9.60 SHARED - USE PATH MARKINGS M-11.10 RAILROAD CROSSING LAYOUT M-12.10 ROUNDABOUT PAVEMENT MARKINGS M-20.10 LONGITUDINAL MARKING PATTERNS M-20.30 LONGITUDINAL MARKING SUPPLEMENT WITH RAISED PAVEMENT MARKERS M-20.40 LONGITUDINAL MARKING SUPPLEMENT WITH RPMS ~ TURN LANES M-20.20 PROFILED AND EMBOSSED PLASTIC LINES M-24.20 SYMBOL MARKINGS ~ TRAFFIC ARROWS FOR HIGH-SPEED ROADWAYS M-24.40 SYMBOL MARKINGS ~ TRAFFIC ARROWS FOR LOW-SPEED ROADWAYS M-24.60 SYMBOL MARKINGS MISCELLANEOUS LONGITUDINAL PAVEMENT MARKINGS SHALL CONSIST OF PROFILED AND EMBOSSED METHYL METHACRYLATE MMA), OR UNLESS OTHERWISE APPROVED BY CITY OF RENTON PUBLIC WORKS/TRANSPORTATION. SUPPLEMENTAL TYPE 2 RAISED PAVEMENT MARKERS WITH REFLECTORS SHALL BE REQUIRED ON ROADWAYS WITH SPEED LIMITS OF 30 MPH OR HIGHER, OR UNLESS OTHERWISE APPROVED BY CITY OF RENTON PUBLIC WORKS/TRANSPORTATION. SUPPLEMENTAL TYPE 2 RAISED PAVEMENT MARKERS WITH REFLECTORS SHALL BE REQUIRED ON ROADWAYS WITH SPEED LIMITS OF 25 MPH OR LOWER, WHERE MINIMUM REQUIRED LIGHTING LEVELS ARE NOT MET AND/OR WHERE CITY OWNED STREET LIGHTS DO NOT EXIST, OR UNLESS OTHERWISE APPROVED BY CITY OF RENTON PUBLIC WORKS/TRANSPORTATION. PAVEMENT LETTERS, AND RED/GREEN PAVEMENT BACKGROUNDS SHALL CONSIST OF METHYL METHACRYLATE MMA), OR UNLESS OTHERWISE APPROVED BY CITY OF RENTON PUBLIC WORKS/TRANSPORTATION. PAVEMENT SYMBOLS, CROSSWALK MARKINGS, AND STOP BARS SHALL CONSIST OF HYDROCARBON THERMOPLASTIC, OR UNLESS OTHERWISE APPROVED BY CITY OF RENTON PUBLIC WORKS/TRANSPORTATION. THERMOPLASTIC SHALL CONTAIN 3M 50/50 WET/DRY ELEMENTS, OR APPROVED EQUAL. IF INSTALLED ON CONCRETE, PAVEMENT SYMBOLS, CROSSWALK MARKINGS, AND STOP BARS SHALL BE 3M STAMARK ALL WEATHER TAPE 380AW SERIES, OR APPROVED EQUAL. SPEED CUSHION CHEVRON SYMBOLS SHALL CONSIST OF 3M STAMARK ALL WEATHER 380AW SERIES TAPE. LONGITUDINAL PAVEMENT MARKINGS CONSISTING OF PAINT SHALL BE USED FOR MAINTENANCE PURPOSES, OR UNLESS OTHERWISE APPROVED BY CITY OF RENTON PUBLIC WORKS/TRANSPORTATION. LONGITUDINAL PAVEMENT MARKINGS WHERE ALL MARKINGS ARE TO CONSIST OF RAISED PAVEMENT MARKERS SHALL REQUIRE APPROVAL FROM CITY OF RENTON PUBLIC WORKS/TRANSPORTATION. IF APPROVED, LONGITUDINAL LANE MARKINGS SHALL FOLLOW WSDOT STD. PLAN M-20.50-02 LONGITUDINAL MARKING SUBSTITUTION W/RAISED PAVEMENT MARKERS. PAVEMENT SURFACE AND AIR TEMPERATURE AT THE TIME OF PAVEMENT MARKING APPLICATION SHALL NOT BE LESS THAN 50° F. DocuSign Envelope ID: FFA9ADCA-D050-445F-B750-15F9271FC791 4/4/2024 | 4:24 PM PDT 1 1 VARIES 1 1 MIN MIN MIN I MIN SPECIAL NOTE: T < } x , 4 IN THE EVENT TRANSVERSE PATCHES EXIST I ; WITHIN THE AFFECTEO STREET, THE LENGTH I I IOFTHEPATCHSHALLBEEXTENDEDTO INCLUDE ANY EXISTING PATCH WITHIN 10 j FEET OF THE EDGE OF THE PATCH REQUIRED iFORTHENEWCROSSINGANDANYf . . SUBSEQUENT PATCH EDGE WITHIN 70 FEE7 OF THE EDGE OF THE SECOND PATCH AND SO ON UP TO A TOTAL OF 300 FEET. I FACE OF GUTTER OR i I EDGE OF PAVEMENT k -=f-- a ; TRAFFIC FLOW 2" HMA I r a d` i i CENTER LINE ORILANELWE 2" TO 8" HMA i I 6.5' MIN. 2" DEPTH OF PLANING OR SAWCUT AND REMOVE VARIES: 6.5' MIN. DEPTH OF EXISTING PAVEMENT MIN I MIN VARIES { MIN I MINI 2" SAWCUT AND REMOVE OR PLANE, SEAL WITH 2" - 6" MIN. HMA (SEE NOTE 2) AR-4000W EACH SIDE) 6" CRUSHED SURFACWG TOP COURSE (CSTC) 2" HMA 9-03.9(3)) PER WSDOT STANDARO SPECIFICATIONS, COMPACTED TO 95% MODIFIED PROCTOR. SAWCUT AFTER BACKFILL EACH SIDE) CSTC, BANK RUN GRAVEL FOR TRENCH BACKFILL 9-03.19), GRAVEL BORROW (9-03.14(1)) PER WSDOT STANDARD SPECIFICATIONS OR NATIVE MATERIAL IF APPROVED IN WRITING BY ENGINEER BASED ON GEOTECH REPORT, COMPACTED TO 95% MODIFIED PROCTOR. WIDTH OF TRENCH AS RE UIRED BY SIZE OF PROPOSED IMPROVEMENT (SEE WSDOT STANDARD SPECIFICATION 2-09.4) PLUS AN ALLOWANCE FOR ANY SHORING. SHORING, IF PIPE ZONE BEDDING. MATERIAL- SEE STANDARDNEEDED, SHALL MEET THE REQUIREMENTS OF WSDOT PLAN 110.1. STANDARD SPECIFICATION 7-08.3(1)B TRENCH WIDTH FOR NOTES, SEE STANDARD PLAN 110.1 TYPICAL TRANSVERSE PATCH FOR p - 110 PUBLIC WORKS FLEXIBLE PAVEMENT OR RIGID F'}'R 'E;D DEPARTMENT u j,.,, PAVEMENT WITN OVERLAY r T VARIES: 4.5' MIN. LANE LINE MARKING SAWCUT AFTER BACKFILL DEPTH OF EXISTING PAVEMENT 2" - 6" HMA 5EE NOTE 2) EDGE OF PAVEMENT, EDGE OF CURB & GUTTER, OR MIN. MIN. CENTER OF LANE MARKING 2" HMA (SEE NOTE 2) 6" CRUSHED SURFACING TOP COURSE CSTC) (9-03.9(3)) PER WSDOT STANDARD 2" SAWCUT AND REMOVE SPECIFCATIONS, COMPACTED TO 95% OR PLANE, SEAL WITH MODIFIED PROCTOR AR-4000W CSTC, BANK RUN GRAVEL FOR TRENCH BACKFILL 9-03.19), GRAVEL BORROW (9-03.14(1)) PER WSDOT STANDARD SPECIFICATIONS OR NATIVE MATERIAL IF APPROVED IN WRITING BY ENGINEER BASED ON GEOTECH REPORT, COMPACTED TO WIDTH OF TRENCH AS REQUIRED BY SIZE OF 95 MODIFIED PROCTOR. PROPOSED IMPROVEMENT (SEE WSDOT STANDARD SPECIFICATION 2-09.4) PLUS AN PIPE ZONE BEDDING MATERIAL AND COMPACTION AS ALLOWANCE FOR ANY SHORING. SHORING, IF REQUIRED BY THE WSDOT STANDARD 5PECIFICATIONS NEEDED, SHALL MEET THE REQUIREMENTS OF FOR THE TYPE OF IMPROVEMENT INSTALLED, EXCEPT: WSDOT STANDARD SPECIFICATION 7-08.3(1)B * FOR STORM AND WATER PIPE, PER STD PLAN 220.0 FOR SANITARY SEWER, PER STD PLAN 405 TRENCH WIDTH * FOR JOINT UTILITY TRENCH, SAND WITH 95 PASSING A #4 SIEVE AND LESS THAN 5 PASSING A #200 SIEVE NOTES: 1. WHEN EXISTWG PAVEMENT IN A LANE REQUIRING A FULL WIDTH REPLACEMENT IS BROKEN OR DETERIORATED TO A PAVEMENT CONDITION INDEX RATING OF 70 OR LESS, THE EXISTING PAVEMENT IN THAT LANE, AND FOR THAT DISTANCE SO CLASSIFIED, SHALL BE REMOVED AND REPLACED WITH HMA MATCHING THE DEPTH USED IN THE EXISTING STREET OR THE DEPTH PER CITY STANDARD, WHICHEVER IS GREATER. 2. PRINCIPAL/ MINOR/COLLECTOR, ARTERIAL, & INDUSTRIAL ACCESS STREETS - MATERIAL AND THICKNESS SHALL BE HMA CL " PG 64-22 AND MATCH EXISTING THICKNESS AND IN NO CASE LESS THAN 6". RESIDENTIAL ACCESS STREETS - HMA CL " PG 64-22. THE THICKNESS SHALL BE THAT OF THE EXISTING PAVEMENT SECTION AND IN NO CASE LESS TNAN 4". 3. WHEN THE "SAWCUT AFTER BACKFILL" ENCROACHES INTO AN ADJACENT LANE, CURB & GUTTER OR SHOULDER, THE AFFECTED LANE SHALL BE PLANED AND OVERLAID WITH HMA FULL WIDTH, THE CURB & GUTTER SHALL BE REMOVED AND REPLACED, OR THE SHOULDER SHALL BE PLANED OR REMOVED AND OVERLAID WITH HMA. 4. IF TRENCH UNDERMINES EXISTING SIDEWALK AND/OR CURBS, THEN THE SIDEWALK AND/OR CURB SHALL BE REPLACED FROM EXPANSION JOINT TO EXPANSION JOINT. 5. IF TRENCHING THROUGH EXISTING DRNEWAY OR SIDEWALK RAMP, THE DRIVEWAY OR SIDEWALK RAMP SHALL BE REPLACED TO MEET ADA STANDARDS. TYPICAL LONGITUDINAL PATCH S"PD. PLAN - 110.1 PUBLIC WORKS FOR FLEXIBLE PAVEMENT OR P1'R ;1;D DEPARTMENT RIGID PAVEMENT WITH OVERLAY o LANE ] LAt E LANE i f t ii 1 : f I f l j 4 INITIAL 2" DEEP SAWCUT OR GRIND, AND LIMIT OF FINAL OVERLAY. GRIND AND PAVE r FULL STREET WIDTH OVERLAY REQUIRED. J 'r t 1 J f/ t I ce: t(. p_. 2: t -, / . -I / t' If r .. }t , 1 i f 1` I t f EDGE OF EXISTING PAVEMENT 11 EDGE OF TRAVELED LANE (EDGE STRIPE) t VARIES: 4.5' MIN. (SEE STD PLAN 110.1) f I CENTER OF ANY MARKED LANE LINE, PROVIDE NEW CHANNELIZATION AFTER OVERLAY F t1 i r SECONDARY FULL DEPTH SAWCUT FOR 4 PROPOSED TRENCH t f I INITIAL 2" DEEP SAWCUT OR GRIND, AND f LIMIT OF FINAL OVERLAY. GRIND AND PAVE FULL STREET WIDTH OVERLAY REQUIRED CANE LAtV LANE r ___ _0 i __ FOR TYPICAL SECTION AND NOTES SEE STANDARD PLAN 110.1 3TD. PLAN - 110.2 PUBLIC WORKS REQUIRED SAWCUT, GRIND AND ppR' 'I,D: DEPARTMENT OVERLAY FOR LONGITUDINAL TRENCHES Q - DocuSign Envelope ID: 9D9B0DA8-0385-4664-AE66-57BFF1561D7F 7/27/2022 | 5:44 PM PDT DocuSign Envelope ID: 9D9B0DA8-0385-4664-AE66-57BFF1561D7F 7/27/2022 | 5:44 PM PDT BAND - OR MOUNTING ON EXISTING METAL POLE OR LUMINAIRE MIN. NOTES 1. DIMENSIONS FOR THE PARTS USED TO ASSEMBLE THE BASE CONNECTIONS ARE INTENTIONALLY NOT SHOWN. BASE CONNECTIONS ARE PATENTED, MANUFACTURED PRODUCTS THAT ARE IN COMPLIANCE WITH NCHRP 350 CRASH TEST CRITERIA. THE BASE CONNECTION DETAILS ARE SHOWN ON THIS PLAN ONLY TO ILLUSTRATE HOW THE PARTS ARE ASSEMBLED. 2. A 2- (IN) POST WITH A 2 1/4" (IN) PSST ANCHOR OR A 2 1/4" (IN) POST WITH A 2 1/2" (IN) PSST ANCHOR MAY BE SUBSTITUTED. SEE CONTRACT PLANS. 3. PERFORATED SQUARE STEEL POST SHALL MEET THE REQUIREMENTS OF WSOOT STANDARD SPECIFICATION 9-06. 4. USE ONLY BASE CONNECTION MANUFACTURER SUPPLIED HARDWARE THAT MEETS THE REQUIREMENTS OF WSDOT STANDARD SPECIFICATIONS 9-06 AND 9-28. EDGE OF TRAVELED ROADWAY 90-F,3C FOR REFLECTORIZED SIGNS: MOUNT FACING 3'(degree) OUTWARD IF SIGN IS WITHIN 30 FEET OF ROADWAY SIGN FACE ORIENTATION BOLT STOPGN POST TYPE ST -4 SIGN SUPPORT OST SUPPORT — 2.25" HOT—DIP GALV., ANCHOR ON CRE 1E MOUNTING ON METAL POST SIGN MOUNTING ON SINGLE STD. PLAN- 129isPUBLICWORKSMETALPOSTAPPROVED: tiZ + DEPARTMENT ( ADOPTED ( /V nerc SIGN POST s LOWER SIGN e 5/16" (IN) CORNER BOLT IN) POST SUPPORT OR 3/6' FLANGED SHOULDER BOLT NTH NUT AND WASHERS 2 REQUIRED (TYP.) BOLT STOPGN POST TYPE ST -4 SIGN SUPPORT OST SUPPORT — 2.25" HOT—DIP GALV., ANCHOR ON CRE 1E MOUNTING ON METAL POST SIGN MOUNTING ON SINGLE STD. PLAN- 129isPUBLICWORKSMETALPOSTAPPROVED: tiZ + DEPARTMENT ( ADOPTED ( /V nerc DocuSign Envelope ID: B16CE03A-ED99-4F11-B559-FEB382C92BFB 7/30/2018 | 4:09 PM PDT PRECAST BASE SECTION SEE NOTE 1 NOTES: 1.AS ACCEPTABLE ALTERNATIVES TO THE REBAR SHOWN IN THE PRECAST BASE SECTION, FIBERS (PLACED IN ACCORDANCE WITH STANDARD SPECIFICATION 9-05.50(9)), OR WIRE MESH HAVING A MINIMUM AREA OF 0.12 SQUARE INCHES PER FOOT SHALL BE USED WITH THE MINIMUM REQUIRED REBAR SHOWN IN THE ALTERNATIVE PRECAST BASE SECTION. WIRE MESH SHALL NOT BE PLACED IN THE KNOCKOUTS. AS AN ACCEPTABLE ALTERNATIVE TO THE REBAR SHOWN IN THE RECTANGULAR ADJUSTMENT SECTION, WIRE MESH HAVING A MINIMUM AREA OF 0.12 SQUARE INCHES PER FOOT MAY BE USED. 2.THE KNOCKOUT DIAMETER SHALL NOT BE GREATER THAN 20". KNOCKOUTS SHALL HAVE A WALL THICKNESS OF 2" MINIMUM TO 2.5" MAXIMUM. PROVIDE A 1.5" MINIMUM GAP BETWEEN THE KNOCKOUT WALL AND THE OUTSIDE OF THE PIPE. AFTER THE PIPE IS INSTALLED, FILL THE GAP WITH JOINT MORTAR IN ACCORDANCE WITH STANDARD SPECIFICATION 9-04.3. 3.THE MAXIMUM DEPTH FROM THE FINISHED GRADE TO THE LOWEST PIPE INVERT SHALL BE 5 FEET. 4.THE FRAME AND GRATE MUST BE INSTALLED WITH THE FLANGE DOWN. 5.THE PRECAST BASE SECTION MAY HAVE A ROUNDED FLOOR, AND THE WALLS MAY BE SLOPED AT A RATE OF 1H:24V OR STEEPER. 6.THE OPENING SHALL BE MEASURED AT THE TOP OF THE PRECAST BASE SECTION. 7.ALL PICKUP HOLES SHALL BE GROUTED FULL AFTER THE INLET HAS BEEN PLACED. USE GROUT TYPE 2 FOR NON-SHRINK APPLICATIONS IN ACCORDANCE WITH STANDARD SPECIFICATION 9-20.3(2). 8.ALL GRADE RINGS AND CASTINGS SHALL BE SET IN MORTAR IN ACCORDANCE WITH STANDARD SPECIFICATION 9-04.3. THEN APPLY MORTAR TO INSIDE AND OUTSIDE OF ALL JOINTS, RINGS, RISERS, AND FRAMES. 9.MORTAR SHALL BE MIXED AND APPLIED PER MANUFACTURER'S DIRECTIONS. 10.FRAME SHALL BE ADJUSTED TO PAVEMENT GRADE BY TAPPING UNTIL FRAME IS FLUSH WITH PAVEMENT AS DETERMINED WITH A STRAIGHT EDGE OF SUFFICIENT LENGTH. 11.ALL MORTAR JOINTS SHALL BE TRIMMED FLUSH AND REMAIN VISIBLE UPON COMPLETION. FRAME AND VANED GRATE RECTANGULAR ADJUSTMENT SECTION 34" 24" 30 20 5" 5" 1", 2", 4", 6", 12", OR 24" ONE #3 BAR HOOP FOR 6" HEIGHT INCREMENT (SPACED EQUALLY), SEE NOTE 1 PIPE ALLOWANCES PIPE MATERIAL MAXIMUM INSIDE DIAMETER REINFORCED OR PLAIN CONCRETE 12" ALL METAL PIPE 15" CPSSP*, STD. SPEC. 9-05.20 12" SOLID WALL PVC, STD. SPEC. 9-05.12(1)15" PROFILE WALL PVC, STD. SPEC. 9-05.12(2) 15" CORRUGATED POLYETHYLENE STORM SEWER PIPE 26", S E E N O T E 6 22SE E N O T E 6 3"4"44" 21" MIN.4" MI N. (T Y P.)3 BAR EACH SIDE 3 BAR EACH WAY 3 BAR EACH CORNER 3 BAR EACH CORNER 18" MIN.3 BAR HOOP ALTERNATIVE PRECAST BASE SECTION CATCH BASIN TYPE 1 STD. PLAN - 200. 00PUBLIC WORKS DEPARTMENT APPROVED: DATEGregg Zimmerman Public Works Administrator UNLESS OTHERWISE NOTED, DRAWING IS NOT TO SCALE (NTS)DocuSign Envelope ID: 6EECF5B6-602A-4E4A-B436-A317AA638878 9/28/ REDUCING SECTION 36 20 40" 24" 6" 8" 8" 12" 4"32",SEE N O T E6 28 SE E N O T E 6 4" MI N. (T Y P.)44" 2"PRECAST BASE SECTION SEE NOTE 1 ALTERNATIVE PRECAST BASE SECTION NOTES:1.AS ACCEPTABLE ALTERNATIVES TO THE REBAR SHOWN IN THE PRECAST BASE SECTION, FIBERS (PLACED IN ACCORDANCE WITH STANDARD SPECIFICATION 9-05.50(9)), OR WIRE MESH HAVING A MINIMUM AREA OF 0. 12 SQUARE INCHES PER FOOT SHALL BE USED WITH THE MINIMUM REQUIRED REBAR SHOWN IN THE ALTERNATIVE PRECAST BASE SECTION. WIRE MESH SHALL NOT BE PLACED IN THE KNOCKOUTS. AS AN ACCEPTABLE ALTERNATIVE TO THE REBAR SHOWN IN THE RECTANGULAR ADJUSTMENT SECTION, WIRE MESH HAVING A MINIMUM AREA OF 0.12 SQUARE INCHES PER FOOT MAY BE USED.2.THE KNOCKOUT DIAMETER SHALL NOT BE GREATER THAN 26". KNOCKOUTS SHALL HAVE A WALL THICKNESS OF 2" MINIMUM TO 2.5" MAXIMUM. PROVIDE A 1.5" MINIMUM GAP BETWEEN THE KNOCKOUT WALL AND THE OUTSIDE OF THE PIPE. AFTER THE PIPE IS INSTALLED, FILL THE GAP WITH JOINT MORTAR IN ACCORDANCE WITH STANDARD SPECIFICATION 9-04.3.3.THE MAXIMUM DEPTH FROM THE FINISHED GRADE TO THE LOWEST PIPE INVERT SHALL BE 5'.4.THE FRAME AND GRATE MUST BE INSTALLED WITH THE FLANGE DOWN.5.THE PRECAST BASE SECTION MAY HAVE A ROUNDED FLOOR, AND THE WALLS MAY BE SLOPED AT A RATE OF 1H:24V OR STEEPER.6.THE OPENING SHALL BE MEASURED AT THE TOP OF THE PRECAST BASE SECTION.7.ALL PICKUP HOLES SHALL BE GROUTED FULL AFTER THE INLET HAS BEEN PLACED.USE GROUT TYPE 2 FOR NON-SHRINK APPLICATIONS IN ACCORDANCE WITH STANDARD SPECIFICATION 9-20.3(2).8.ALL GRADE RINGS AND CASTINGS SHALL BE SET IN MORTAR IN ACCORDANCE WITH STANDARD SPECIFICATION 9-04.3. THEN APPLY MORTAR TO INSIDE AND OUTSIDE OF ALL JOINTS, RINGS, RISERS, AND FRAMES.9.MORTAR SHALL BE MIXED AND APPLIED PER MANUFACTURER'S DIRECTIONS.10.FRAME SHALL BE ADJUSTED TO PAVEMENT GRADE BY TAPPING UNTIL FRAME IS FLUSH WITH PAVEMENT AS DETERMINED WITH A STRAIGHT EDGE OF SUFFICIENT LENGTH.11.ALL MORTAR JOINTS SHALL BE TRIMMED FLUSH AND REMAIN VISIBLE UPON COMPLETION. FRAME AND VANED GRATE RECTANGULAR ADJUSTMENT SECTION 34" 24" 30 20 5"5"1", 2", 4", 6", 12", OR 24"ONE #3 BAR HOOP FOR 6" HEIGHT INCREMENT (SPACED EQUALLY),SEE NOTE 1 3 BAR EACH CORNER 18" MIN.3 BAR HOOP PIPE ALLOWANCES PIPE MATERIAL MAXIMUM INSIDE DIAMETER REINFORCED OR PLAIN CONCRETE 18" ALL METAL PIPE 21"CPSSP*,STD. SPEC. 9-05.20 18"SOLID WALL PVC,STD. SPEC. 9- 05.12(1) 21"PROFILE WALL PVC,STD. SPEC. 9- 05.12(2) 21"CORRUGATED POLYETHYLENE STORM SEWER PIPE TWO #3 BAR HOOPS 3 BAR EACH SIDE 3 BAR EACH WAY 3 BAR EACH CORNER CATCH BASIN TYPE 1L STD. PLAN - 200. 10 PUBLICWORKS DEPARTMENT APPROVED:DATEGregg Zimmerman Public Works Administrator UNLESS OTHERWISE NOTED, DRAWING IS NOT TO SCALE (NTS)DocuSign Envelope ID: 6EECF5B6- 602A-4E4A-B436-A317AA638878 9/28/2018 | 4"25"PRECAST BASE SECTION NOTES:1.AS ACCEPTABLE ALTERNATIVES TO THE REBAR SHOWN IN THE PRECAST BASE SECTION, FIBERS ( PLACED IN ACCORDANCE WITH STANDARD SPECIFICATION 9-05. 50(9)),OR WIRE MESH HAVING A MINIMUM AREA OF 0. 12 SQUARE INCHES PER FOOT SHALL BE USED WITH THE MINIMUM REQUIRED REBAR SHOWN IN THE ALTERNATIVE PRECAST BASE SECTION. WIRE MESH SHALL NOT BE PLACED IN THE KNOCKOUTS. AS AN ACCEPTABLE ALTERNATIVE TO THE REBAR SHOWN IN THE RECTANGULAR ADJUSTMENT SECTION, WIRE MESH HAVING A MINIMUM AREA OF 0.12 SQUARE INCHES PER FOOT MAY BE USED.2.THE KNOCKOUT DIAMETER SHALL NOT BE GREATER THAN 18". KNOCKOUTS SHALL HAVE A WALL THICKNESS OF 2"MINIMUM TO 2.5" MAXIMUM. PROVIDE A 1.5" MINIMUM GAP BETWEEN THE KNOCKOUT WALL AND THE OUTSIDE OF THE PIPE. AFTER THE PIPE IS INSTALLED, FILL THE GAP WITH JOINT MORTAR IN ACCORDANCE WITH STANDARD SPECIFICATION 9- 04.3.3.THE MAXIMUM DEPTH FROM THE FINISHED GRADE TO THE LOWEST PIPE INVERT SHALL BE 5'.4.THE FRAME AND GRATE SHALL BE INSTALLED WITH THE FLANGE DOWN.5.THE PRECAST BASE SECTION MAY HAVE A ROUNDED FLOOR,AND THE WALLS MAY BE SLOPED AT A RATE OF 1H: 24V OR STEEPER.6.THE STRUCTURE OPENING DIMENSIONS SHALL BE MEASURED AT THE TOP OF THE PRECAST BASE SECTION.7.ALL PICKUP HOLES SHALL BE GROUTED FULL AFTER THE INLET HAS BEEN PLACED. USE GROUT TYPE 2 FOR NON-SHRINK APPLICATIONS IN ACCORDANCE WITH STANDARD SPECIFICATION 9-20. 3(2).8.ALL GRADE RINGS AND CASTINGS SHALL BE SET IN MORTAR IN ACCORDANCE WITH STANDARD SPECIFICATION 9- 04.3.THEN APPLY MORTAR TO INSIDE AND OUTSIDE OF ALL JOINTS, RINGS, RISERS, AND FRAMES.9.MORTAR SHALL BE MIXED AND APPLIED PER MANUFACTURER' S DIRECTIONS.10.FRAME SHALL BE ADJUSTED TO PAVEMENT GRADE BY TAPPING UNTIL FRAME IS FLUSH WITH PAVEMENT AS DETERMINED WITH A STRAIGHT EDGE OF SUFFICIENT LENGTH.11.ALL MORTAR JOINTS SHALL BE TRIMMED FLUSH AND REMAIN VISIBLE UPON COMPLETION.FRAME AND VANED GRATE RECTANGULAR ADJUSTMENT SECTION 4" MI N. (T Y P.)26",SEE N O T E6 22 SE E N O T E 6 SEE NOTE 1 ALTERNATIVE PRECAST BASE SECTION 3 BAR EACH SIDE TOP AND BOTTOM 3 BAR EACH CORNER ONE # 3 BAR ACROSS BOTTOM 3 BAR EACH CORNER 18" (MIN.)3 BAR HOOP PIPE ALLOWANCES PIPE MATERIAL MAXIMUM INSIDE DIAMETER REINFORCED OR PLAIN CONCRETE 12"ALL METAL PIPE 15"CPSSP* ,STD. SPEC. 9- 05. 20 12"SOLID WALL PVC,STD. SPEC. 9-05. 12( 1)15"PROFILE WALL PVC,STD. SPEC. 9-05. 12( 2)15"CORRUGATED POLYETHYLENE STORM SEWER PIPE 34" 24" 30 20 5"5"1", 2", 4", 6", 12", OR 24"ONE #3 BAR HOOP FOR 6" HEIGHT INCREMENT ( SPACED EQUALLY),SEE NOTE 1 CONCRETE INLET STD. PLAN - 200.30 PUBLIC WORKS DEPARTMENTAPPROVED: DATEGregg Zimmerman Public Works Administrator UNLESS OTHERWISE NOTED, DRAWING IS NOT TO SCALE (NTS)DocuSign Envelope ID: 6EECF5B6-602A-4E4A- B436-A317AA638878 9/28/2018 | 9:45 2' 11-1/2" 2' 2"4-3/4"4-3/4" 2' 7"1' 10" 4-1/2" 4-1/2" DRA I N 3' 4" 3' 3' 6-1/4" 1' 11-1/2" 2' 9-1/2"2' 5" 6" 8" 3' 8" 5-1/2" 6" 5' 5-3/4" ONE #4 BAR HOOP 4s EACH SIDE OF OPENING CONVERSION RISER Ø 2' 6" 8" CONVERSION RISER ADJUSTMENT RINGS CONVERSION RISER STD. PLAN - 200.40 PUBLIC WORKS DEPARTMENT APPROVED: DATEGreggZimmerman Public Works Administrator UNLESS OTHERWISE NOTED, DRAWING IS NOT TO SCALE (NTS) DEPTH: 3.52' TO IE OUT DocuSign Envelope ID: 6EECF5B6-602A-4E4A-B436-A317AA638878 9/28/2018 | 9:45 AM PDT NOTES: 1.NO STEPS ARE REQUIRED WHEN HEIGHT IS 4' OR LESS. 2.THE BOTTOM OF THE PRECAST CATCH BASIN MAY BE SLOPED TO FACILITATE CLEANING. 3.THE RECTANGULAR FRAME AND GRATE MUST BE INSTALLED WITH THE FLANGE DOWN. THE FRAME MAY BE CAST INTO THE ADJUSTMENT SECTION. 4.KNOCKOUTS SHALL HAVE A WALL THICKNESS OF 2" MINIMUM TO 2.5" MAXIMUM. PROVIDE A 1.5" MINIMUM GAP BETWEEN THE KNOCKOUT WALL AND THE OUTSIDE OF THE PIPE. AFTER THE PIPE IS INSTALLED, FILL THE GAP WITH JOINT MORTAR IN ACCORDANCE WITH STANDARD SPECIFICATION 9-04.3. 5.ALL GRADE RINGS, RISERS, AND CASTINGS SHALL BE SET IN MORTAR IN ACCORDANCE WITH STANDARD SPECIFICATION 9-04.3. 6.WHEN CONNECTING TO A NEW PIPE, USE A FLEXIBLE CONNECTOR (KOR-N-SEAL BOOT WITH CORRUGATED PIPE ADAPTER OR APPROVED EQUAL). WHEN CONNECTING TO AN EXISTING PIPE, USE A FABRICATED SAND COLLAR OF THE SAME MATERIAL AS THE CONNECTING PIPE. 7.MORTAR SHALL BE MIXED AND APPLIED PER MANUFACTURER'S DIRECTIONS. 8.FRAME SHALL BE ADJUSTED TO PAVEMENT GRADE BY TAPPING UNTIL FRAME IS FLUSH WITH PAVEMENT AS DETERMINED WITH A STRAIGHT EDGE OF SUFFICIENT LENGTH. 9.ALL MORTAR JOINTS SHALL BE TRIMMED FLUSH AND REMAIN VISIBLE UPON COMPLETION. CATCH BASIN FRAME AND VANED GRATE PER STD. PLAN 204.00 RECTANGULAR OR CIRCULAR ADJUSTMENT SECTION (TWO SECTIONS MAX.) MORTAR, (TYP.), SEE NOTE 5 FLAT SLAB TOP SEE NOTE 6, TYP. REINFORCING STEEL, (TYP.) GRAVEL BACKFILL FOR PIPE ZONE BEDDING PER WSDOT STD. SPECIFICATION SECTION 9-03.12(3) INTEGRAL BASE PRECAST WITH RISER STEPS OR LADDER 4" MIN. 16" MAX.28" MAX. 48", 54", 60", 72", 84", 96", 120" OR 144" 12" (TYP.) 24" MIN. 12" MAX. 1" MIN. 2.5" MAX. 12" 6" 15' MAX. FOR MAINTENANCE SEPARATE BASE PRECAST O" RING 12" 6" CATCH BASIN DIMENSIONS CATCH BASIN DIAMETER MIN. WALL THICKNESS MIN. BASE THICKNESS MAXIMUM KNOCKOUT SIZE MINIMUM DISTANCE BETWEEN KNOCKOUTS 48"4"6"36"8" 54"4.5"8"42"8" 60"5"8"48"8" 72"6"8"60"12" 84"8"12"72"12" 96"8"12"84"12" 120"10"12"96"12" 144"12"12"108"12" PIPE ALLOWANCES CATCH BASIN DIAMETER PIPE MATERIAL WITH MAXIMUM INSIDE DIAMETER CONCRETE ALL METAL CPSSP 1 SOLID WALL PVC 2 PROFILE WALL PVC 3 48"24"30"24"30"30" 54"30"36"30"36"36" 60"36"42"36"42"42" 72"42"54"42"48"48" 84"54"60"54"48"48" 96"60"72"60"48"48" 120"66"84"60"48"48" 144"78"96"60"48"48" 1 CORRUGATED POLYETHYLENE STORM SEWER PIPE (STD. SPEC. 9-05.20) 2 STD. SPEC. 9-05.12(1) 3 STD. SPEC. 9-05.12(2) CATCH BASIN TYPE 2 STD. PLAN - 201.00 PUBLIC WORKS DEPARTMENT APPROVED: DATEGreggZimmerman Public Works Administrator UNLESS OTHERWISE NOTED, DRAWING IS NOT TO SCALE (NTS) DocuSign Envelope ID: 6EECF5B6-602A-4E4A-B436-A317AA638878 9/28/2018 | 9:45 AM PDT NOTES: 1.THIS FRAME IS DESIGNED TO ACCOMMODATE 20" × 24" GRATES OR COVERS,SEE STANDARD PLANS 204.10, 204.20, AND 204.30.2. BOLT-DOWN CAPABILITY IS REQUIRED ON ALL FRAMES, GRATES, AND COVERS, UNLESS OTHERWISE SPECIFIED. PROVIDE TWO HOLES IN THE FRAME THAT ARE VERTICALLY ALIGNED WITH THE GRATE OR COVER SLOTS.THE FRAME SHALL ACCEPT THE 5/8"-11 NC x 2" ALLEN HEAD CAP SCREW BY BEING TAPPED, OR OTHER APPROVED MECHANISM. LOCATION OF BOLT- DOWN HOLES VARIES BY MANUFACTURER.3. REFER TO STANDARD SPECIFICATION 9-05.15(2) FOR ADDITIONAL REQUIREMENTS. GRATE FRAME SEE NOTE 2 RECESSED ALLEN HEAD CAP SCREW 5/ 8" - 11 NC x 2"SECTION A DETAIL TOP ISOMETRIC VIEW BOLT- DOWN HOLE (TYP.) ~ 5/8",11 NC, SEE DETAIL AND NOTE 2 29 1/4"25 1/4"SECTION BOLT-DOWN DETAIL 24 1/4"SEE DETAIL 3/ 4"4 1/2"1 5/8"2 1/2"1 5/8"1 1/4"3/ 4"7/ 8"1/ 8"ARECTANGULAR FRAME STD. PLAN - 204.00 PUBLIC WORKS DEPARTMENT APPROVED: DATEMartin PastuchaPublic Works Administrator UNLESS OTHERWISE NOTED, DRAWING IS NOT TO SCALE (NTS)DocuSign Envelope ID: E212B987-C626-4330-A5D4-D055A0107AF9 10/ 19/2022 | 2:52 PM PDT NOTES: BOLT-DOWN SLOT DETAIL SEE NOTE 1 SECTION A TOP SECTION B SECTION C 1.BOLT-DOWN CAPABILITY IS REQUIRED ON ALL FRAMES, GRATES, AND COVERS, UNLESS OTHERWISE SPECIFIED. PROVIDE TWO HOLES IN THE FRAME THAT ARE VERTICALLY ALIGNED WITH THE GRATE OR COVER SLOTS. THE FRAME SHALL ACCEPT THE 5/8"-11 NC x 2" ALLEN HEAD CAP SCREW BY BEING TAPPED, OR OTHER APPROVED MECHANISM. LOCATION OF BOLT-DOWN HOLES VARIES BY MANUFACTURER. 2.ALTERNATIVE REINFORCING DESIGNS ARE ACCEPTABLE IN LIEU OF THE RIB DESIGN. 3.REFER TO STANDARD SPECIFICATION 9-05.15(2) FOR ADDITIONAL REQUIREMENTS. 4.FOR FRAME DETAILS, SEE CITY OF RENTON STANDARD PLAN 204.00. 24" 1 1/2" 3" R26", SEE NOTE 2 BOLT-DOWN SLOT, SEE DETAIL AND NOTE121/2" DIA. HOLE 1 5/8" MAX. 4 3/4"1 1/2" 3" R39", SEE NOTE 2 1 1/2" 1/2" DIA. HANDLE 3/4" DIA. HOLE 5/8" 3/4" 4" 3 1/2" 5" 1/2" 3/4" 1 1/4" 5/8"ACB20" ISOMETRIC PUBLIC WORKS DEPARTMENT APPROVED: DATEGreggZimmerman Public Works Administrator UNLESS OTHERWISE NOTED, DRAWING IS NOT TO SCALE (NTS) RECTANGULAR SOLID METAL COVER STD. PLAN - 204.10 DocuSign Envelope ID: 6EECF5B6-602A-4E4A-B436-A317AA638878 9/28/2018 | 9:45 AM PDT NOTES: ISOMETRIC SECTION B TOPFOUNDRY NAMEDIFLOW SECTION A 1.BOLT-DOWN CAPABILITY IS REQUIRED ON ALL FRAMES, GRATES, AND COVERS, UNLESS OTHERWISE SPECIFIED. PROVIDE TWO HOLES IN THE FRAME THAT ARE VERTICALLY ALIGNED WITH THE GRATE OR COVER SLOTS. THE FRAME SHALL ACCEPT THE 5/8"-11 NC x 2" ALLEN HEAD CAP SCREW BY BEING TAPPED, OR OTHER APPROVED MECHANISM. LOCATION OF BOLT-DOWN HOLES VARIES BY MANUFACTURER. 2.REFER TO STANDARD SPECIFICATION 9-05.15(2) FOR ADDITIONAL REQUIREMENTS. 3.FOR FRAME DETAILS, SEE STANDARD PLAN 204.00. FLOWFLOWBOLT-DOWN SLOT DETAIL SEE NOTE 1 1/2" 3/4" 1 1/4" 5/8" BOLT-DOWN SLOT, SEE DETAIL AND NOTE 1 20" 5" 5" 5" 3" 1" 3" 5" 5" 5" DIRECTION OF FLOW 24" 7 OR 8 EQUAL SPACES 1 5/8" MAX. A BOUTFALL TO STREAM DUMP NO POLLUTANTS 3/8" RECESSED LETTERING RECTANGULAR VANED GRATE STD. PLAN - 204.20 PUBLIC WORKS DEPARTMENT APPROVED: DATEGreggZimmerman Public Works Administrator UNLESS OTHERWISE NOTED, DRAWING IS NOT TO SCALE (NTS) DocuSign Envelope ID: 6EECF5B6-602A-4E4A-B436-A317AA638878 9/28/2018 | 9:45 AM PDT ISOMETRIC NOTES: SECTION B TOPFOUNDRY NAMEDIFLOW SECTION A 1.BOLT-DOWN CAPABILITY IS REQUIRED ON ALL FRAMES, GRATES, AND COVERS, UNLESS OTHERWISE SPECIFIED. PROVIDE TWO HOLES IN THE FRAME THAT ARE VERTICALLY ALIGNED WITH THE GRATE OR COVER SLOTS. THE FRAME SHALL ACCEPT THE 5/8"-11 NC x 2" ALLEN HEAD CAP SCREW BY BEING TAPPED, OR OTHER APPROVED MECHANISM. LOCATION OF BOLT-DOWN HOLES VARIES BY MANUFACTURER. 2.REFER TO STANDARD SPECIFICATION 9-05.15(2) FOR ADDITIONAL REQUIREMENTS. 3.USE ONLY IN SAGS ON VERTICAL CURVES. 4.FOR FRAME DETAILS, SEE STANDARD PLAN 204.00. FLOWFLOWBOLT-DOWN SLOT DETAIL SEE NOTE 1 1/2" 3/4" 1 1/4" 5/8" BOLT-DOWN SLOT, SEE DETAIL AND NOTE 1 20" 5" 5" 5" 3" 1" 3" 5" 5" 5" 24" 1 5/8" MAX. 4 EQUAL SPACES 4 EQUAL SPACES A BOUTFALL TO STREAM DUMP NO POLLUTANTS 3/8" RECESSED LETTERING RECTANGULAR BI-DIRECTIONAL VANED GRATE STD. PLAN - 204.30 PUBLIC WORKS DEPARTMENT APPROVED: DATEGreggZimmerman Public Works Administrator UNLESS OTHERWISE NOTED, DRAWING IS NOT TO SCALE (NTS) DocuSign Envelope ID: 6EECF5B6-602A-4E4A-B436-A317AA638878 9/28/2018 | 9:45 AM PDT COVER SECTION VIEW ASTM A48 CL35B00371780MO/ DA/YR X3717C1PTEON BOLTING DETAIL GASKET GROOVE DETAIL FRAME SECTION VIEW COVER BOTTOM VIEW PLAN VIEW DRAINIFCOMADEINUSA EJIW DUMPNO P OL LU T A N T S - DRAINS T O S T REAMR E N T O N NOTES:1.ALL COVERS SHALL BE LOCKING LID PER EJ No. 3717C1 OR APPROVED EQUAL.1/2" LETTERING BOLT HOLES - 3 PLACES EQUALLY SPACED 120° APART ON 23 1/16" DIA. B. C.1 1/4" LETTERING 1) 1" DIA. PICKHOLE 25" DIA.3/ 4"1"2 1/ 2"8 3/4"TYP.) 3) BLT SOC. (ALLEN HEAD)5/8"-11 x 1.5 SS RUBBER WASHER 5/ 8"25 1/4" DIA.26 1/2" DIA.23 3/8" DIA. CL OPEN 27 5/16" DIA.34 1/ 8" DIA.1 1/16"6"1/8" 1/4" 1 1/16"R1/8" 1/4" DIA. NEOPRENE GASKET STORM ROUND FRAME AND COVER PUBLIC)STD. PLAN - 204. 50PUBLIC WORKS DEPARTMENT APPROVED: DATEMartin Pastucha Public Works Administrator UNLESS OTHERWISE NOTED, DRAWING IS NOT TO SCALE (NTS)DocuSign Envelope ID: 3B1B34D3-7E0A-476C-ADB3-4329FFE0C108 8/13/ FLEXIBLE PIPE NOTES: 1.PROVIDE UNIFORM SUPPORT UNDER BARRELS. 2.HAND TAMP UNDER HAUNCHES. 3.DIRECTLY OVER PIPE, HAND TAMP ONLY. 4.SEE STANDARD WSDOT/APWA SPECIFICATIONS SECTION 2-09.4 FOR TRENCH WIDTH. 5.PIPE ZONE BEDDING AND BACKFILL MATERIAL SHALL BE PLACED IN 6" LOOSE LAYERS AND COMPACTED TO 95% MAXIMUM DENSITY. 6.EXCAVATE UNSTABLE MATERIAL DOWN TO FIRM SOIL AND REPLACE WITH FOUNDATION MATERIAL CLASS A OR B PER STANDARD WSDOT/APWA SPECIFICATIONS SECTION 9-03.17. SEE NOTE 4, LIMIT OF PIPE ZONE 6" O.D. 6" FOUNDATION LEVEL PIPE ZONE BEDDING AND BACKFILL, SEE NOTE 5 FLEXIBLE PIPE PIPE TYPE MINIMUM COVER (FT) PUBLIC?PRIVATE? ALLOWED IN ZONE 1 OF THE APA? LINE CORRUGATED POLYETHYLENE PIPE (LCPE)2.0 YES YES YES CORRUGATED POLYETHYLENE PIPE (CPE) - TRIPLE WALL 2.0 YES YES YES POLYVINYL CHLORIDE PIPE (PVC)3.0 YES YES YES SOLID WALL HIGH DENSITY POLYETHYLENE PIPE (HDPE)2.0 YES YES YES POLYPROPYLENE PIPE (PP) - DUAL WALL 2.0 YES YES YES DIAMETER MINIMUM DISTANCE BETWEEN BARRELS 12" TO 24"12" 30" TO 96"DIAMETER / 3 102" TO 180"48" GRAVEL BACKFILL FOR PIPE ZONE BEDDING (WSDOT 9-03.12(3)) OR MAINTENANCE ROCK (WSDOT 9-03.9(4)) FOUNDATION MATERIAL, IF REQUIRED, SEE NOTE 6 PIPE ZONE BEDDING AND COMPACTION - FLEXIBLE PIPE STD. PLAN - 220.10 PUBLIC WORKS DEPARTMENT APPROVED: DATEMartinPastucha Public Works Administrator UNLESS OTHERWISE NOTED, DRAWING IS NOT TO SCALE (NTS) DocuSign Envelope ID: 3B1B34D3-7E0A-476C-ADB3-4329FFE0C108 8/13/2020 | 8:48 AM PDT 12" MIN. 6" MIN. , SEE NOTE 4 EXISTING PAVEMENT SURFACE SURFACE RESTORATION AS SPECIFIED IN CONTRACT DOCUMENTS CRUSHED SURFACING TOP COURSE" PER WSDOT STD. SPEC 9-03.9(3), "BANK RUN GRAVEL FOR TRENCH BACKFILL" PER WSDOT STD. SPEC 9-03.19, OR "GRAVEL BORROW" PER WSDOT STD. SPEC 9-03.14(1), COMPACTED TO 95% OF MAXIMUM DENSITY BENCH AS NEEDED FOR SHORING SYSTEM WHEN DEPTH IS 4' OR GREATER PIPE ZONE BEDDING AND BACKFILL PER STD. PLANS 220.00 AND 220.10 PIPE NEAT LINE TRENCH UNPAVED AREAS PAVED AREAS SEE NOTE 1 NOTES: 1.SEE WSDOT/APWA STANDARD SPECIFICATIONS SECTION 2-09.4 FOR MEASUREMENT OF TRENCH WIDTH. 2.EXCAVATIONS OVER 4' DEEP SHALL COMPLY WITH THE SAFETY STANDARD DESCRIBED IN CHAPTER 295-155 PART N OF THE WAC. 3.MAXIMUM BACKFILL DEPTH ABOVE PIPE SHALL NOT BE EXCEEDED, AS DETERMINED BY PIPE MANUFACTURER. 4.IN PAVED AREAS, IF PIPE HAS LESS THAN 3' OF COVER, USE "CRUSHED SURFACING TOP COURSE" FOR THE ENTIRE BACKFILL DEPTH ABOVE PIPE ZONE. 5.SEE CONSTRUCTION PLANS FOR SPECIFIC PROJECT REQUIREMENTS. SEE STANDARD PLANS 110, 110.1, 110.2, AND 111 FOR PAVEMENT RESTORATION REQUIREMENTS CRUSHED SURFACING TOP COURSE" PER WSDOT STD. SPEC 9-03.9(3), COMPACTED TO 95% OF MAXIMUM DENSITY TYPICAL TRENCH AND BACKFILL STD. PLAN - 220.20 PUBLIC WORKS DEPARTMENT APPROVED: DATEGreggZimmerman Public Works Administrator UNLESS OTHERWISE NOTED, DRAWING IS NOT TO SCALE (NTS) DocuSign Envelope ID: 6EECF5B6-602A-4E4A-B436-A317AA638878 9/28/2018 | 9:45 AM PDT TYPICAL CLEANOUT CONFIGURATION GENERAL NOTES: 1.CLEANOUTS FOR UNDERDRAIN, FOOTING DRAIN COLLECTOR, AND ROOF DRAIN COLLECTOR PIPES SHALL BE INSTALLED AT A MINIMUM OF EVERY 100 FEET, AT EVERY 90 DEGREE OR SECOND 45 DEGREE BEND, AT THE END OF EVERY COLLECTOR PIPE, AND AT EACH END OF AN UNDERDRAIN PIPE NOT CONNECTED TO AN OVERFLOW STRUCTURE. CLEANOUTS SHALL BE INSTALLED TO ALLOW FOR MAINTENANCE ACCESS TO ALL PIPES. 2.ALL FITTINGS SHALL BE SOIL TIGHT. 3.CLEANOUT RISER SHALL BE LOCATED OUTSIDE OF BIORETENTION PONDING WHERE POSSIBLE. 4.CLEANOUTS SHALL NOT BE LOCATED WITHIN THE STREET TRAVEL LANE, UNLESS OTHERWISE APPROVED BY THE CITY. DESIGN PONDING ELEVATION SOIL TIGHT 45° BEND EXTEND CLEANOUT RISER 2" ABOVE DESIGN PONDING ELEVATION OR PER PLAN 4" STREAMBED COBBLES PER WSDOT 9-03.11(2) SOIL TIGHT COUPLER UNDERDRAIN, FOOTING DRAIN COLLECTOR, OR ROOF DRAIN COLLECTOR PIPE, SEE NOTE 1 WYE MECHANICAL PLUG OR CONTINUED CONNECTION FERNCO GASKETED QUIK CAP OR SIMILAR CAST IRON FRAME AND COVER, SEE NOTE 3 CLEANOUT RISER, SEE NOTE 2 PAVED AREA (TYP.) TO OVERFLOW STRUCTURE OR STORM MAIN CLEANOUT RISER LOCATED WITHIN BIORETENTION PONDING AREA NOTES: 1.DIAMETER TO BE 6-INCHES MINIMUM PRIVATE, 8-INCHES MINIMUM PUBLIC. UNDERDRAIN PIPE PER STD. PLAN 262.10. 2.CLEANOUT RISER SHALL BE SAME MATERIAL AS CONNECTED UNDERDRAIN, FOOTING DRAIN COLLECTOR, OR ROOF DRAIN COLLECTOR PIPE. 3.FRAME AND COVER SHALL BE EJ PRODUCTS 3675Z1PT AND 3675APT OR APPROVED EQUAL. COVER TO BE LOCKING WITH ALLEN HEAD BOLT, MARKED "STORM" OR DRAIN". 4.FOR CLEANOUTS FULLY OR PARTIALLY WITHIN UNPAVED AREAS OUTSIDE OF BIORETENTION PONDING AREA, POUR 8" THICK, 2'x2' SQUARE CONCRETE COLLAR AROUND FRAME. CONCRETE COLLAR SHALL HAVE A MINIMUM COMPRESSIVE STRENGTH OF 3,000 PSI. CLEANOUT RISER, SEE NOTE 2 FRAME SECTION 10-1/2" DIA 4" 5/8" 9" DIA 15" DIA 8-1/8" DIA 8-13/16" DIA 5/8" COVER SECTION MADE IN USA 1" PLAN VIEW PROD NO.3/4" FLAT FACE GOTHIC 2) 3/8"-16 SS SOCKET HEAD CAP SCREW (ALLENHEAD) W/WSHRS ON A 8" DIA BOLT CIRCLE 1) OPENPICKHOLE 12"12"4" COMPACTED SAND OR GRAVEL BACKFILL FOR DRAINS PER WSDOT 9-03. 12(4)8" CLASS "B"ASPHALT, SEE NOTE 4 STORM SYSTEM CLEANOUT STD. PLAN - 226.00 PUBLIC WORKS DEPARTMENTAPPROVED: DATEMartin Pastucha Public Works Administrator UNLESS OTHERWISE NOTED, DRAWING IS NOT TO SCALE (NTS)DocuSign Envelope ID: 3B1B34D3-7E0A-476C- ADB3-4329FFE0C108 8/13/2020 | 8:48 CURB, CEMENT CONCRETE MOUNTABLE LANE MARKERS, TYPE No.2 USE 12 FOR s 15' DIA. USE 16 FOR - 20' DIA. USE 20 FOR : 20' DIA. THROUGH JOINTS: USE 4 FOR < 20' DIA. USE 8 FOR ? 20' DIA. 5" TYP 10 PLANT MATERIAL TREE PLANTING: USE 3 TREES EQUAL SPACED FOR >15' DIA. USE 1 TREE, CENTERED FOR <15' DIA. OBJECT MARKER, SIGN CODE, W -81(P4-12) 2-#3 BARS TYP. BETWEEN JOINTS) 3-#3 CURB DOWELS TYP. BETWEEN JPOINTS) PICAL TRAFFIC CIRCLE CURB, CEMENT CONCRETE MOUNTABLE (DOWELED) LANE MARKER, TYPE No.2 1" :NDI EX. CONC. OR ASPH./CONC. PAVEMENT CONCRETE PAVEMENT 3 BARS 3 CURB DOWEL TREE PLANTING TYP. 2' 1' PLANT MATERIAL 4" 5" - PLANT MULCH(2") TOP SOIL (3") 1 3:1 SLOPE FILL, MATERIAL AGGREGATE TYPE 10 3 BARS J / 6 .REMOVE PAVEMENT 3 CURB DOWEL ` LINE DRILL TYPICAL SECTION LANE MARKER, TYPE No.2 CURB, CEMENT CONCRETE MOUNTABLE SEE TYP. SECTION ABOVE FOR DIMENSIONS. TYPICAL SECTION NOT TO SCALE nwr NAKAF- "ni5 CP PArF-1-101, TRAFFIC CIRCLE lTY p ADOPTED VOA CITY OF RENTON STANDARD PLANS IV TT0 LST DATE:04/04 nwr NAKAF- "ni5 CP PArF-1-101, i.-•=.-vm.,,,^J..,-.a;e-m r'.'.+—!^-^-+rrc-^vn3-x_._.. r ,.fie. ,_.3`-+F.r-,.,..._,.e,-„...... EDGE aFSNmRDDi — OR7URNDUr AT EDGE OF SHOULDER A TYISr P1ATE SEEDErAly S/EE'rSte 1 LSEE NOIE01 FACEN I QaiB h IYPE( WTYPeOF ' SUPPORT r F CUPo vNUE.S vME. VARIES) SmE BEHIND CURB MAILBOX PLACEMENT. SECTIONS eNeOx S101 1,1A OR] (TYPU R aLALPS PER B= n rBra IIIA 4—r w i us ua ua ' ua ua u wa wa nra ws I—a-mitBEIMEENxa90)k6 vMWarorr BEHIND SIDEWALK NOTES: 1. An mfu.hble platform may be used In Ocu of Cha platform design shown on Rtis nlan. Adjustable platforms must fit Ue bracket design drown on gds plan. required. required. seeeresulted for all single post inslellalfons. Field adtag may be 2. A Type 2 support is requlmd when 2 of more mares em to be Installed on one support A meKimum of 6 mailboxes may be installed on a Type 2 suppartSeeStd. Spec. 932.7. 3. Attach as crews r box to a steeligsstwhit two 170 Muller Clem stated lag both m aFie 7refnlholesinspf box mai n the Newspaperepamorotlwmust• M& affiM beyond the tramof the 4. rng of mallson mounting holes varies among manufa haves. AttachmentoMemailboxtogreWatlortnmayrequiredMingadddionalholesthroughthe mallbai to at the platform S. Comer the maiDox on the plaUpm to ensure apace far Ne msExar door.to open and to albw spam far Igshging the fostoem. S. A Socket endSnoring system may be 6ubsgWteci M fieu of me =IL twist Dlate assemb for single steel posts shown on this plan. The socket and wedge anchoring system shag meet NCHRP 360 cash teat afteria. Anb-teht replatesanot mqu tar wood post insfagatans. EcmmwcoxmucP SEE DETAIL. aEaaET+7 e _ eiEELPoSi. WpODPoIIi-oq z*^^ .. t ..__ ...,.,,, .. _.._ _ OP110R . OPTKIN I ., , . .. (PItOPpre'GRYDtlIONIIROMIO DODARE TYPE ISUPPORT r. ., -- • ,,. ,. - TYPE 2SUPPORT r - MAILBOX SPACING DETAIL ” -:. $APTED oeks Inu"rauu nw.r r: . an' T`04 j "rf« -n .s`3.:• NCO r+ r CAST DAT PIEEA "'. TON LANS T 151099!2002, -- 20-/- WOOD POST FASTENERS IM HTM WOWA••W • 1 WOWL•W • e • k mAx•W • e • R/ NA6B0X5,, 1A ORx eoLre ouANlm uD£ 1A eNOMO vu]wERs loaonlls sEETauESItEEEra U,S FOR De1FBVSIONS) 1 WDVBL•W 0 sEs NOTE s) q tM'oUN.W NYLON PLSEIfL. e sErs LUel Tlma ft mmSEEDETaLS 3) SEE NOTE 1) W • • W MEA NFAD BOLT, 2 L'YASI¢RS e m crypj GM 3) AnomowaL REOW mTYUSETO iB1 DPP (fYP.) W • Mf NIX BDLT 2YMSNERSaLOCIOarGYP.) STEEL POST FASTENERS eoLre ouANlm eyrDK ti N- vu]wERs loaonlls STADEPRO110)m- J W OLAM.2W 2 1 WDVBL•W 0 sEs NOTE s) q tM'oUN.W e 1rsMNVAP f nr(e MCLANP,, I aro Posr I PLATFORMSEEDEYNL 6NEEfA SEE NDTE II eyrDK ti N- STADEPRO110)m- JFUIFORY ON BOm ENDS TO a1DWACOESS TO FABf p sEs NOTE s) q INSTALLATION ALIGNMENT DETAIL W • 2Yf NEX BOLT 2tWefhT96LOOIONEO a BAACThT RYPa SEE DETAIL eHETTa) w rna•No1E frYPa b melw,Ecma eyrDK tiN- p` DD.NBINO EXPIRES MAY,$.2W IWDOD POST ISEESID.SPEC.o-zaup)1 MAILBOX1Tle'NOFf1EliCWIP 2sYASNERaA INSTALLATION aNrvrxtsrnATB f •°••••••' - DEMJL'`, &1EET]j .— m.]LOCN1Mf9GYP/ em..p.we...-....r..... TYPE"1'S'TYPE'2"' SEE f nr(e MCLANP,, STANDARD PLAN.. H-12'. PE, DaaFlaMFn , VADOP ` A`S CITY OF RENTON WOOD PO8TASSEMBLY DETAIL SEE 67EEL POSTASSEMBLY DML °i ^N• '„°.11 w STEEL POSTASSEMBLY DETAIL I tf, STANDARD PLANSTµ toRDEra)sNorsnwAllL.-Lp,STDATE 05/09/2002=_ PSP PAOfiHO2H' 4 - Tom^.^^^_.. Y, q v—ml qK J NIIFRECLYP FRONT VIEW TnP ow.) -\ + BOTTOMVIEW SNOW GUARD DETAIL nGIE tON 7 WEDwummYETI! Zlo1•d SECTION OA TW 2W 2W TOP VIEW 0 malawl 0 I I ISOMETRIC VIEW W' _H ...F -r. _.__.._.. .. MAILBOX a PLATFORM DNENSIONS - w2no2mm+soxs Pu,raau auwsroxs W L W N 1 1P ntn' B +r P' P 2 u n +2 W1 m• +r +• TOP VIEW L ` ` (IYP4 mr-w ISIDEYEN PLATFORM DETAIL TnP UWL(iYPJ I FRONTVPW 7 rN END VIEW TYPE 1 S TYPE 2 _ -,- STANDARD PLAN.H•12.. ET+ovamaE,s ` ADOPTED eT CITY.OF.RENTON' r-- O oT STANDARD PIANS - • .` o+ . LASTDATE 05(09!2002. SP PAGE=HO29 r. r. wnna,E t P'0VF%PA,JDm+etTK 1 00000d10°0060000O U00v0000000000990000000000'00000000M.00000000000' 000000000000000000000000000000 0000000000000000000000000 I'll 0 00 00000000000040040000000009000011 000 000900094p0040000090000000000 d00o40,11, 090 0 000 00 ,.. v—ml qK J NIIFRECLYP FRONT VIEW TnP ow.) -\ + BOTTOMVIEW SNOW GUARD DETAIL nGIE tON 7 WEDwummYETI! Zlo1•d SECTION OA TW 2W 2W TOP VIEW 0 malawl 0 I I ISOMETRIC VIEW W' _H ...F -r. _.__.._.. .. MAILBOX a PLATFORM DNENSIONS - w2no2mm+soxs Pu,raau auwsroxs W L W N 1 1P ntn' B +r P' P 2 u n +2 W1 m• +r +• TOP VIEW L ` ` (IYP4 mr-w ISIDE YEN PLATFORM DETAIL TnP UWL(iYPJ I FRONTVPW 7 rN END VIEW TYPE 1 S TYPE 2 _ -,- STANDARD PLAN.H•12.. ET+ovamaE,s ` ADOPTED eT CITY.OF.RENTON' r-- O oT STANDARD PIANS - • .` o+ . LASTDATE 05(09!2002. SP PAGE=HO29 (MKMXEPP]WMKRIHF]67GSXX>IPPIV (EXI  (EXI   HORIZONTAL BEND VALVE ANCHOR PLUGGED TEE TEE OFFSET PLUGGED CROSS VERTICAL BEND ALTERNATE VERTICAL BEND PLUGGED CROSS PLUGGED END FOR FUTURE EXPANSION DWG. NO. CONCRETE BLOCKING DETAIL W-1A Gregory G. Hill, P.E. GENERAL NOTES: PIPE SIZE MINIMUM BEARING AREA (SF) · · · FITTING DWG. NO. MINIMUM BEARING AREA DETAIL W-1B Gregory G. Hill, P.E. GENERAL NOTES: PIPE SIZE REQUIRED LENGTH (FT) OF RESTRAINED JOINT PIPE · · · · · · DWG. NO. RESTRAINED PIPE LENGTH DETAIL W-1C Gregory G. Hill, P.E. ROADWAY WITH CURB AND GUTTER AND/OR SIDEWALK ROADWAY WITH DITCHES DWG. NO. TYPICAL ROADWAY SECTIONS FOR RESIDENTIAL SUBDIVISION W-2 Gregory G. Hill, P.E. ROADWAY WITH DITCHES ROADWAY WITH CURB AND GUTTER DWG. NO. TYPICAL ROADWAY SECTIONS W-3 Gregory G. Hill, P.E. FIRE HYDRANT LOCATION FIRE HYDRANT ASSEMBLY IN CUT OR FILL DWG. NO. FIRE HYDRANT ASSEMBLY ROLLED CURB W-4 Gregory G. Hill, P.E. IN CUT OR FILL FIRE HYDRANT LOCATION FIRE HYDRANT ASSEMBLY DWG. NO. FIRE HYDRANT ASSEMBLY VERTICAL CURB W-5 Gregory G. Hill, P.E. DETAIL FIRE HYDRANT ASSEMBLY FIRE HYDRANT LOCATION IN CUT OR FILL DWG. NO. FIRE HYDRANT ASSEMBLY COMMERCIAL W-6 Gregory G. Hill, P.E. IN CUT OR FILL FIRE HYDRANT LOCATION FIRE HYDRANT ASSEMBLY PLAN VIEW FIRE HYDRANT IN FILL FIRE HYDRANT IN CUT DWG. NO. FIRE HYDRANT ASSEMBLY GRAVEL SHOULDER W-7 Gregory G. Hill, P.E. DWG. NO. A/C WATER MAIN REPLACEMENT @ WATER MAIN CROSSING W-12 Gregory G. Hill, P.E. VALVE MARKER POST BLOW-OFF ASSEMBLY MARKER POST VALVE BOX PROTECTIVE PAD DWG. NO. VALVE BOX PROTECTIVE PAD AND MARKER POST W-13 Gregory G. Hill, P.E. DWG. NO. VALVE OPERATING NUT EXTENSION W-14 Gregory G. Hill, P.E. PLAN ELEVATION DWG. NO. WATER SERVICE CONNECTION ONE INCH W-15 Gregory G. Hill, P.E. SINGLE SERVICE DWG. NO. METER SETTER DETAIL W-16 Gregory G. Hill, P.E. SINGLE SERVICE PLAN VIEW DWG. NO. INSTALLATION DETAIL FOR NEW SERVICE TRANSFER TO EXISTING METER W-16A Gregory G. Hill, P.E. SO OS CREE K W A T E R &SEWE R DI ST RI CT DWG. NO. 4", 6" OR 8" TEMPORARY BLOWOFF ASSEMBLY W-17 Gregory G. Hill, P.E. RAVEN LID N1324BLKWAT WITH SOOS CREEK LOGO RAVEN PLASTIC HDPE METER BOX NO. RMB132412-SWM-W DWG. NO. HDPE METER BOX FOR 1" METER W-18 Gregory G. Hill, P.E. DWG. NO. METER INSTALLATION W-19 Gregory G. Hill, P.E. PLAN ELEVATION DWG. NO. WATER SERVICE CONNECTION 1-1/2 INCH AND 2-INCH W-20 Gregory G. Hill, P.E. ELEVATION END VIEW DWG. NO. 1-1/2" & 2" METER SETTERS (ALTERNATE NO. 1) W-21 Gregory G. Hill, P.E. END VIEWELEVATION DWG. NO. 1-1/2" & 2" METER SETTERS (ALTERNATE NO. 2) W-22 Gregory G. Hill, P.E. ELEVATION END VIEW DWG. NO. 1-1/2" & 2" IRRIGATION METER SETTERS (ALTERNATE NO. 1) W-23 Gregory G. Hill, P.E. END VIEWELEVATION DWG. NO. 1-1/2" & 2" IRRIGATION METER SETTERS (ALTERNATE NO. 2) W-24 Gregory G. Hill, P.E. PLAN ELEVATION BY-PASS DETAIL (BRASS PIPE)PIPE SLEEVE DETAIL DWG. NO. DOUBLE CHECK DETECTOR BACKFLOW PREVENTION ASSY. W-25A Gregory G. Hill, P.E. GENERAL NOTES: VAULT SIZES PIPE SIZE MATERIAL LIST DWG. NO. DOUBLE CHECK DETECTOR MAT'L LIST AND GENERAL NOTES W-25B Gregory G. Hill, P.E. DWG. NO. LOCKING FRAME & COVER DETAIL W-25C Gregory G. Hill, P.E. PLAN ELEVATION PIPE SLEEVE DETAIL DWG. NO. 3", 4" AND 6" METERS W-26A Gregory G. Hill, P.E. MATERIAL LIST METER SIZE GENERAL NOTES: VAULT SIZES DWG. NO. 3", 4" AND 6" METERS MAT'L LIST AND GENERAL NOTES W-26B Gregory G. Hill, P.E. DWG. NO. LOCKING FRAME & COVER DETAIL W-26C Gregory G. Hill, P.E. ELEVATION PLAN DWG. NO. 3" TURBO METER W-27A Gregory G. Hill, P.E. MATERIAL LIST GENERAL NOTES: PIPE SLEEVE DETAIL DWG. NO. 3" TURBO METER MAT'L LIST & GENERAL NOTES W-27B Gregory G. Hill, P.E. DWG. NO. 2" AIR/VACUUM VALVE CHAMBER W-28 Gregory G. Hill, P.E. PLAN ELEVATIONEND VIEW DWG. NO. PIPE ANCHOR DETAIL W-29 Gregory G. Hill, P.E. PLAN ELEVATION DWG. NO. SACK SLOPE RETAINER W-30 Gregory G. Hill, P.E. FILTER FABRIC FENCE NOTES: 6' MAX POST SPACING MAY BE INCREASED TO 8' IF WIRE BACKING IS USED 2' - 0 " MI N 12 " MI N FILTER FABRIC JOINT, SEE NOTE 2 FILTER FABRIC 2" x 2" x 14 GA WIRE OR EQUIVALENT, IF STANDARD STRENGTH FABRIC USED FILTER FABRIC BACKFILL TRENCH WITH NATIVE SOIL OR 3/4" TO 1-1/2" WASHED GRAVEL WRAP FABRIC AROUND TRENCH MINIMUM 4" x 4" TRENCH 2" x 4" WOOD POSTS, STEEL FENCE POSTS, REBAR, OR EQUIVALENT 1.FILTER FABRIC FENCES SHALL BE INSTALLED ALONG CONTOURS WHENEVER POSSIBLE. 2.FILTER FABRIC SHALL BE PURCHASED IN A CONTINUOUS ROLL CUT TO THE LENGTH OF THE BARRIER TO AVOID USE OF JOINTS. WHEN JOINTS ARE NECESSARY, FILTER FABRIC SHALL BE SPLICED AT POSTS WITH A MINIMUM 6-INCH OVERLAP. USE STAPLES, WIRE RINGS, OR EQUIVALENT TO ATTACH FABRIC TO POSTS. 3.INSTALL FILTER FABRIC ACCORDING TO THE MANUFACTURER'S SPECIFICATIONS. 4.INSTALL THE ENDS OF THE FILTER FABRIC FENCE TO POINT SLIGHTLY UPSLOPE TO PREVENT SEDIMENT FROM FLOWING AROUND THE ENDS OF THE FENCE. 5.FILTER FABRIC FENCES SHALL BE REMOVED WHEN THEY HAVE SERVED THEIR USEFUL PURPOSE, BUT NOT BEFORE THE UPSLOPE AREA HAS BEEN PERMANENTLY STABILIZED. 6.FILTER FABRIC FENCES SHALL BE INSPECTED IMMEDIATELY AFTER EACH RAINFALL AND AT LEAST DAILY DURING PROLONGED RAINFALL. ANY REQUIRED REPAIRS SHALL BE MADE IMMEDIATELY. 7.WHEN SEWER SERVICES CROSS FILTER FABRIC FENCE, SERVICE TRENCH, DITCH SECTION, AND FILTER FABRIC FENCE SHALL BE RESTORED IMMEDIATELY. 8.TEMPORARY EROSION AND SEDIMENT CONTROL MEASURES SHALL MEET OR EXCEED ALL APPLICABLE PERMIT REQUIREMENTS. ADHERENCE TO THIS DETAIL DOES NOT RELIEVE THE CONTRACTOR FROM PROJECT PERMIT REQUIREMENTS. DWG. NO. FILTER FABRIC FENCE W-31 Gregory G. Hill, P.E. DWG. NO. TYPICAL UTILITY / WATER MAIN CROSSING W-32 Gregory G. Hill, P.E. TRENCH WIDTHS NOTES: DWG. NO. TYPICAL TRENCH DETAIL W-33 Gregory G. Hill, P.E. TRENCH WIDTHS NOTES: DWG. NO. TYPICAL TRENCH DETAIL (OUTSIDE ROADWAY) W-34 Gregory G. Hill, P.E. DWG. NO. VERTICAL REDIRECTION OF SCWSD WATER MAIN W-35A Gregory G. Hill, P.E. DWG. NO. HORIZONTAL REDIRECTION OF SCWSD WATER MAIN W-35B Gregory G. Hill, P.E.