Loading...
HomeMy WebLinkAbout006.1.1 Kiwanis Park As-Builds - ConformsCity of Renton / BDA Date: 09/08/23 Job No. TD-215 Parks Planning & Natural Resources Division ATTN: Michael Faulkner 1055 South Grady Way RE: BDA Renton, WA 98057 Contract #CAG-22-013 Phone: 425-430-6571 Fax: Transmittal # 1.1 We are transmitting the following to you: Enclosed Under Separate Cover Via __________ Drawings Plans Specifications Product Data Samples Copy of Letter Submittal Contract Change Order Material prepared by: Copies Date Number Description 1 9-8-23 2 Kiwanis Park As-Build Resubmittal These are transmitted as checked below: Remarks: For Approval For your Use As requested Approved as Submitted Approved as Noted For Review and Comment Sent via: email Signed: Jarod Emerson CLT, CA LETTER OF TRANSMITTAL # 006.1.1 BRUCE DEES & ASSOC. RECEIVED SEP 8 2023 Please provide additional info regarding the following items:1. Conduit runs along Union Ave (See RFI 17) - please provide alignment and elevations.2. Utility stubup location / orientation for future Portland Loo.3. Irrigation sleeves / tie-in at existing west pathway and landscape buffer4. Northern Union Ave terminus - fence and retaining wall alignments5. Old septic tank locationCONFORMS TO DESIGN CONCEPTCONFORMS TO DESIGN CONCEPT WITHREVISIONS / NOTATIONS AS SHOWNNON-CONFORMANCE -- REVISE & RESUBMITTHIS SHOP DRAWING / SUBMITTAL HAS BEEN REVIEWED FORGENERAL CONFORMANCE WITH DESIGN CONCEPT ONLY AND DOESNOT RELIEVE THE FABRICATOR / VENDOR OF RESPONSIBILITY FORCONFORMANCE WITH DESIGN DRAWINGS AND SPECIFICATIONS, ALLOF WHICH HAVE PRIORITY OVER THIS SHOP DRAWING / SUBMITTAL.BY __________________________________ DATE ___________________BRUCE DEES & ASSOCIATESMike Faulknern09/13/2023 5'-0"Decommissioned SepticTank Location Painted Yellow Fence extension to meetneighboring fenceDeletion of CIP WallReinstall of NeighborRetaining Wall line deleted 10'-0"CB X02CB X01Existing CB with Cutand Capped OutfallRelocated French Drain Relocated French DrainFrench DrainConnectedand extendedto CB# 202Type 2 CB to collectexisting (abandoned)Field DrainageDeleted LineNEW CB # 311NEW CB # 312ADDED 8" Storm Domestic Water Stub UpSewer and Electric StubUps see below Detail2" Domestic Assemblymoved North of 3"Irrigation Assembly2" DomesticPOCAssembly3" IrrigationPOCAssemblyCity of Renton 2"Domestic Water MeterDelete 2" Waterline,Meter, and Main TapDelete 2" domestic lineand reconnect to newPOC location north ofIrrigation POCAdd irrigation POCconnection to Mainlineheading South from POCDelete North run of 3"irrigation pipe andconnect to IrrigationSouth of POC. Deleted LinesReroutedLinesAdded JB2XXDeleted Light Fixtures 5'-0"Deleted Electrical LineRerouted Electrical Line Deleted Electrical LinesRerouted Electrical LineDeleted Electrical LineRerouted Electrical LineRerouted Electrical Conduits Top of Conduit 411.55 Fully Sleeved Irrigationline rerouteAdditional Ball ValveDeleted Irrigation Line Irrigation mainline locateddirectly between BP HPGlineDeleted irrigation MainLineArea Sleeved, loaded,and pipe capped. Noexisting irrigation to hookinto.All Remaining sleeves marked ingreen Added 1" Quick CouplerAdded 1" Quick Coupler