HomeMy WebLinkAbout006.1.1 Kiwanis Park As-Builds - ConformsCity of Renton / BDA Date: 09/08/23 Job No. TD-215
Parks Planning & Natural Resources Division ATTN: Michael Faulkner
1055 South Grady Way RE: BDA
Renton, WA 98057 Contract #CAG-22-013
Phone: 425-430-6571
Fax: Transmittal # 1.1
We are transmitting the following to you: Enclosed Under Separate Cover Via __________
Drawings Plans Specifications Product Data Samples
Copy of Letter Submittal Contract Change Order
Material prepared by:
Copies Date Number Description
1 9-8-23 2 Kiwanis Park As-Build Resubmittal
These are transmitted as checked below: Remarks:
For Approval
For your Use
As requested
Approved as Submitted
Approved as Noted
For Review and Comment
Sent via: email
Signed: Jarod Emerson CLT, CA
LETTER OF TRANSMITTAL
# 006.1.1
BRUCE DEES & ASSOC.
RECEIVED
SEP 8 2023
Please provide additional info regarding the following items:1. Conduit runs along Union Ave (See RFI 17) - please provide alignment and elevations.2. Utility stubup location / orientation for future Portland Loo.3. Irrigation sleeves / tie-in at existing west pathway and landscape buffer4. Northern Union Ave terminus - fence and retaining wall alignments5. Old septic tank locationCONFORMS TO DESIGN CONCEPTCONFORMS TO DESIGN CONCEPT WITHREVISIONS / NOTATIONS AS SHOWNNON-CONFORMANCE -- REVISE & RESUBMITTHIS SHOP DRAWING / SUBMITTAL HAS BEEN REVIEWED FORGENERAL CONFORMANCE WITH DESIGN CONCEPT ONLY AND DOESNOT RELIEVE THE FABRICATOR / VENDOR OF RESPONSIBILITY FORCONFORMANCE WITH DESIGN DRAWINGS AND SPECIFICATIONS, ALLOF WHICH HAVE PRIORITY OVER THIS SHOP DRAWING / SUBMITTAL.BY __________________________________ DATE ___________________BRUCE DEES & ASSOCIATESMike Faulknern09/13/2023
5'-0"Decommissioned SepticTank Location
Painted Yellow
Fence extension to meetneighboring fenceDeletion of CIP WallReinstall of NeighborRetaining Wall
line deleted
10'-0"CB X02CB X01Existing CB with Cutand Capped OutfallRelocated French Drain
Relocated French DrainFrench DrainConnectedand extendedto CB# 202Type 2 CB to collectexisting (abandoned)Field DrainageDeleted LineNEW CB # 311NEW CB # 312ADDED 8" Storm
Domestic Water Stub UpSewer and Electric StubUps
see below Detail2" Domestic Assemblymoved North of 3"Irrigation Assembly2" DomesticPOCAssembly3" IrrigationPOCAssemblyCity of Renton 2"Domestic Water MeterDelete 2" Waterline,Meter, and Main TapDelete 2" domestic lineand reconnect to newPOC location north ofIrrigation POCAdd irrigation POCconnection to Mainlineheading South from POCDelete North run of 3"irrigation pipe andconnect to IrrigationSouth of POC.
Deleted LinesReroutedLinesAdded JB2XXDeleted Light Fixtures
5'-0"Deleted Electrical LineRerouted Electrical Line
Deleted Electrical LinesRerouted Electrical LineDeleted Electrical LineRerouted Electrical LineRerouted Electrical Conduits Top of Conduit 411.55
Fully Sleeved Irrigationline rerouteAdditional Ball ValveDeleted Irrigation Line
Irrigation mainline locateddirectly between BP HPGlineDeleted irrigation MainLineArea Sleeved, loaded,and pipe capped. Noexisting irrigation to hookinto.All Remaining sleeves marked ingreen
Added 1" Quick CouplerAdded 1" Quick Coupler