Loading...
HomeMy WebLinkAboutMFP25000916.pdfDEPARTMENT OF COMMUNITY AND ECONOMIC DEVELOPMENT Minor Franchise Permit: MFP25000916 IVR Number: 25000916 Permit Information Permit Name: Puget Sound Energy Gas Permits Address/Location:02/25/2025Application Date:7224000675Parcel Number: 444 PARK AVE N Permit Type:03/12/2025Issue Date:Franchise Permit Work Class:03/12/2026Expiration Date:Minor Utility Job Number: 109156864Franchise Type:Natural Gas Description: PSE Gas CREW TO WORK AT THE INTERSECTION OF PARK AVE N & N 5TH ST. CREW WILL TIE INTO EXISITING MAIN AND INSTALL APPROX 210' OF 2" MPE IP MAIN. CREW WILL TEST AND TIE OVER TWO SERVICES AND ONE RPL. Contacts Name Address PhoneTypeBilling Corrie Rydberg Puget Sound Energy 3702 71st Ave W University Place, WA 98466 C: (253) 905-5031ApplicantX Vicki Henson Potelco Inc 8001 212th St S Kent, WA 98032 B: (253) 863-0484Contractor Business License Number: 5109Electrical Contractor: POTELI*344O4 Construction Contractor: POTELI*227PL Puget Sound Energy Inc 10885 NE 4th Street, PSE08-N08 Bellevue, WA 98009 B: (888) 225-5773Emergency Contact CITY OF RENTON ROW 1055 S Grady Way Renton, WA 98057-3232 Owner Corrie Rydberg Puget Sound Energy 3702 71st Ave W University Place, WA 98466 C: (253) 905-5031Specialized Billing General Conditions & Signature Permission is hereby given for the work described on this permit according to the conditions hereon and according to the approved plans and specifications pertaining thereto, subject to compliance with the Ordinance of the City of Renton. Ÿ This permit and plans must be posted at the job site at all times.Ÿ I hereby certify that no work is to be done except as described above and in approved plans, and that work is to conform to Renton Trench Restoration and Street Overlay Requirements. Ÿ Call 425.430.7203 or go to: https://permitting.rentonwa.gov one working day in advance to schedule an inspections and for ANY work in the Right of Way. Ÿ Call 8 1 1 to locate underground utilities at least two full business days prior to any excavation.Ÿ In accordance with RCW 19.122.033(4) the permit holder is required to contact (Williams Northwest Pipeline at 425.868.1010) (Olympic Pipeline at 425.235.7736) (Puget Sound Energy at 425.375.3397) to request a consultation with the transmission pipeline company prior to performing any construction or excavation activities. This requirement to consult with the transmission pipeline company is in addition to the requirement to Call before You Dig as required in RCW 19.122. Ÿ (Date)(Signature) Page 1 of 1THIS PERMIT AND PLANS MUST BE POSTED AT THE JOB SITE AT ALL TIMES Note: The Applicant is responsible for compliance with all codes and regulations, whether or not described in this document. DEPARTMENT OF PUBLIC WORKS Page 1 of 3 | Published: 10/27/2021 Transportation Division | 1055 South Grady Way, 5th Floor | Renton, WA 98057 | 425-430-7380 Website: rentonwa.gov TRAFFIC CONTROL PLAN APPLICATION Published: 10/27/2021 TRAFFIC CONTROL PLAN (TCP) MUST BE SUBMITTED TO PUBLIC WORKS TRANSPORTATION DIVISION FOR REVIEW/APPROVAL AT LEAST FIVE (5) WORKING DAYS BEFORE THE DATE OF WORK. The City of Renton requires any contractor, firm, corporation, or other public/private agency to prepare a traffic control plan (TCP) and obtain city's approval of that plan when construction, repair, or maintenance work is to be conducted within the city's right-of-way. 1. Fill out the Traffic Control Plan (TCP) Application form and prepare required submittal documents. 2. The following items are all required for submittal of the TCP Application: ☐Electronic Copy of the TCP Application ☐Electronic Copy of the TCP Layout, on 11” X 17” paper size format, which shall: Include map(s) showing the location of the project and work area. Be legible lettering and clear, contrasting, symbols of viewing or printing. Must indicate street names, and north arrow and scale. Types of plans required: o Work hour plan – show all mobility impacts during construction hours. o Non-work plan - show all mobility impacts after work hours when limited or no work is happening in the right-of-way (ROW), if applicable. o Changing construction phases – show construction sequence and each construction phase change even if the traffic control is not modified, if applicable. o Pedestrian access/detour plan, if applicable. - Shall conform to the Washington State Traffic Control Flagger Certification handbook, by the Evergreen Safety Council. 3. Submit Application via email to TCP@rentonwa.gov with the subject line “TCP Application – [Project Name].” Project Name: Permit #: Site Address: Work Date: From _____________ To _____________ Work Time: Start ______________ End ______________ Construction Company: Contact Name: Phone/Cell: _________________________ Business Address: City/State: Zip: Description of Work: Approval By: _________________________________________________ Date:____________________ Transportation Engineering INFRASOURCE, INC 6905 S 228TH ST KENT, WA 98032 PLEASE SEE ATTACHED 109156864 444 PARK AVE N JEFF MCCOY 425-429-5821 MFP25000916 Monday Friday 8:00am 3:00pm Scott Warlick CED 3/12/2025 Note: The Applicant is responsible for compliance with all codes and regulations, whether or not described in this document. Page 2 of 3 | Published: 10/27/2021 PERMIT HOLDER AGREES TO ALL THE FOLLOWING: Must have approved Traffic Control Plan (TCP) prior to commencing the work. Maintain existing pedestrian access. The work on pedestrian facilities, shall be limited to one corner at a time, with the least possible inconvenience or delay to pedestrians. WORK TIME begins when any street or travel lane is fully or partially closed. This includes set up within the traveled way. Comply with all traffic regulations of the City of Renton and the State of Washington. Prepare a traffic control plan and obtain City approval of that plan. That plan shall be implemented for all street and lane closures, and the plan shall be performed in compliance with the Manual on Uniform Traffic Control Devices. Notify emergency services (253-852-2121) twenty-four (24) hours before any street or lane closures. Contractor or entity must call Renton School District (425-204-4455) or any public/private agency, including public transit, to be affected by a temporary lane or road closure a minimum of five business days (excluding weekends and holidays) prior to starting any work. Contractor or entity must notify King County Metro in writing at construction.coord@kingcounty.gov a minimum of five business days (excluding weekends and holidays) prior to starting any work impacting bus stops, a temporary lane or road closure. Work requiring removing a bus shelter or sign requires notification in writing a minimum of 30 business days (excluding weekends and holidays). Please call King County Metro at 206-477-1140 with any questions. Any lane or street closures not in conformance with the approved traffic control plan and/or without notification of emergency services may result in receiving a citation for violation of R.C.W. 47.36.200 Signs or Flaggers at thoroughfare work sites and R.C.W. 9A.36.050 Reckless Endangerment, and other applicable State and City codes. Indemnify and hold harmless the City of Renton from any and all claims, actions, and judgments, including all costs of defense and attorney’s fees incurred in defending against same, arising from and related to implementation of the approved traffic control plans including claims arising from towing of private vehicles and the acts of the Permit Holder’s agents and employees. The City of Renton shall be entitled, in its reasonable discretion, to settle claims prior to suit or judgment, and in such event shall indemnify and hold harmless the City for any such claims paid, including the City’s reasonable attorney’s fees and litigation costs incurred resulting from such claim. In the event any claim or suit is brought against City within the scope of this Agreement, Permit Holder will pay for legal counsel chosen by the City to defend against same. Flagger and sign placement are subject to revision by the City Inspector on site, if needed to address traffic or pedestrian safety or travel. All permit conditions shall be met. NOTES: Total road closure lasting more than twenty-four (24) hours is subject to the approval by the City Council. Work Zone Traffic Control shall be in accordance with the Manual on Uniform Traffic Control Devices (MUTCD) and shown by a traffic control plan layout or reference to WSDOT. Approved Temporary Traffic Control Plan must be at the work site during work hours. Complete assistance and accommodation shall be provided to all kinds of pedestrian traffic when sidewalk or walkway is impeded to safely redirect pedestrians around a work zone. Signage shall be used to warn motorcyclists/bicyclists of the potential hazards on any uneven surfaced or slippery road conditions during work and non-work hours. Any vehicle, equipment, barricade, or portable tow-away sign used within the work area must display a company logo or any legally acceptable sign showing the company name, address, and telephone number at a conspicuous place on the vehicle or equipment. Note: The Applicant is responsible for compliance with all codes and regulations, whether or not described in this document. Page 3 of 3 | Published: 10/27/2021 In the case of Temporary No Parking Zones, all the following apply in addition to previous: Contractor must complete form to show limits of Temporary No Parking Zone identifying barricade locations for vacate parking or curb lane usage. Contractor must post notice of dates and time of Temporary No Parking Zone with at least two signs per block seventy-two (72) hours in advance of effective date and time. The cover sheet of this Traffic Control Plan form must be attached to each Temporary No Parking Sign on the project site. Temporary traffic control devices must be removed immediately when work is done or no construction activities are going on. If deemed abandoned, City crews will remove and store them at the City’s maintenance shop (3555 NE 2nd Street). I certify that the information on this application and within the submittal documents are accurate to the best of my knowledge and I acknowledge all the requirements on this application. Applicant’s Signature Date Applicant’s Name (Print) CORRIE RYDBERG 444 Park Ave N Renton WA 98057 USAN 5TH STPARK AVE N 11111111111111111111111111111311111818PARK AVE N GARDEN AVE NN 5TH STONLYONLY 12 12 12 KEEP R4-7B RIGHTKEEPR4-7BRIGHTCONETOPPERW4-119W4-119W20-1ROADWORKAHEADRIGHT LANECLOSEDAHEADW20-5RW4-2RX'≥X'≥X'≥W20-1ROADWORKAHEADX'≥X'≥X'≥RIGHT LANECLOSEDAHEADW20-5RW1-4LW20-1ROADWORKAHEADX'≥X'≥W1-4RW20-1 ROADWORKAHEADX'≥ W20-1ROADWORKAHEAD X'≥S/WCLOSEDR9-9 C/WCLOSEDR9-3S/W CLOSEDR9-9DETOURM4-9BPLACE PDETOUR SIGNS ATCROSSWALK/ INTERSECTIONEAST / SOUTH OF PARK AVE N& N 6TH STS/WCLOSEDR9-9PLACE PDETOUR SIGNS ATCROSSWALK/ INTERSECTIONEAST / NORTH OF PARK AVEN & N 4TH STDETOURM4-9B DETOURM4-9BS/WCLOSEDR9-9 RESIDENT(S) WILL BE INFORMED OFTEMPORARY DRIVEWAY CLOSURENSIGN SPACINGMPH60/6545/5535/403025"X"1000'500'350'200'100'CHANNELIZATIONDEVICE SPACINGMPH55/7035/4525/30TAPER403020TANGENT806040Project Address:PagePSEPUGETSOUNDENERGYDesigner:Job #REVSafaa Al Neema(425) 398-6077safaa.alneema@pse.com1 OF 2444 Park Ave N, Renton, WA 980570 12012824 01/07/2025Notes:1. All signs and spacing to conform to theMUTCD and City of Renton standards.2. All sidewalks, driveways, exits and egressesshall be completely clear unless otherwise indicated,if indicated use ADA compliant channelization.3. Channelizing devices are 28" traffic cones.Use traffic drums (barrels) with steady burningType C lights on all State State Routes and Hwys.4. Sign size can be a minimum of 36" x 36" andshall not obstruct pedestrian access.5. Crew is required to leave a minimum of 10' fortraveling lane width.6. Alert affected residents and businesses.7. Work to take place during approved work hours asper jurisdictional requirements. (Generally between 9a.m. and 4 p.m. on non-arterials and from 9 a.m. to 3p.m. on arterials. If night time work is approved,signaling and flaggers shall conform to WAC296-155-305. Night time work to take place between_____________and ______________.)8. All Flagger and Downstream tapers shall be 50'-100'.LEGEND28" TRAFFIC CONESIGN LOCATIONTRAFFIC FLOWWORK VEHICLE/FLASHING LIGHTSRIGHT OF WAYWORK AREACHEVRONARROW BOARDFLAGGERUNIFORMEDPOLICE OFFICERPOLICESTOPWORK PITMINIMUM TAPER LENGTH=L (FT.)LANEWIDTH101112207075802510511512530150165180352052252454027029532045475495540POSTED SPEED (MPH)505005506005555060566060-66072065--78070--840TEMPORARY TRAFFIC CONTROL PLANPuget Sound EnergyTraffic Control Supervisor:Safaa Al NeemaCard No. IS 6 100072Card Exp. 10/10/2028Safaa.alneema@pse.com(425)398-6077MFP25000916 444 Park Ave N Renton WA 98057 USAN 5TH STPARK AVE N 11111111111111111111111111111311111818PARK AVE N GARDEN AVE NN 5TH STONLYONLY 12 12 12 W4-119RESIDENT(S) WILL BE INFORMED OFTEMPORARY DRIVEWAY CLOSURECONETOPPERCONETOPPER S/W CLOSEDR9-9DETOURM4-9BS/WCLOSEDR9-9DETOURM4-9BW20-1ROADWORKAHEADX'≥X'≥X'≥W20-1ROADWORKAHEADX'≥X'≥X'≥RIGHT LANECLOSEDAHEADW20-5RW1-4LW20-1ROADWORKAHEADX'≥X'≥W1-4RW20-1 ROADWORKAHEADX'≥ W20-1ROADWORKAHEAD X'≥Project Address:PagePSEPUGETSOUNDENERGYDesigner:Job #REVSafaa Al Neema(425) 398-6077safaa.alneema@pse.com2 OF 2444 Park Ave N, Renton, WA 980570 12012824 01/07/2025Notes:1. All signs and spacing to conform to theMUTCD and City of Renton standards.2. All sidewalks, driveways, exits and egressesshall be completely clear unless otherwise indicated,if indicated use ADA compliant channelization.3. Channelizing devices are 28" traffic cones.Use traffic drums (barrels) with steady burningType C lights on all State State Routes and Hwys.4. Sign size can be a minimum of 36" x 36" andshall not obstruct pedestrian access.5. Crew is required to leave a minimum of 10' fortraveling lane width.6. Alert affected residents and businesses.7. Work to take place during approved work hours asper jurisdictional requirements. (Generally between 9a.m. and 4 p.m. on non-arterials and from 9 a.m. to 3p.m. on arterials. If night time work is approved,signaling and flaggers shall conform to WAC296-155-305. Night time work to take place between_____________and ______________.)8. All Flagger and Downstream tapers shall be 50'-100'.LEGEND28" TRAFFIC CONESIGN LOCATIONTRAFFIC FLOWWORK VEHICLE/FLASHING LIGHTSRIGHT OF WAYWORK AREACHEVRONARROW BOARDFLAGGERUNIFORMEDPOLICE OFFICERPOLICESTOPWORK PITMINIMUM TAPER LENGTH=L (FT.)LANEWIDTH101112207075802510511512530150165180352052252454027029532045475495540POSTED SPEED (MPH)505005506005555060566060-66072065--78070--840TEMPORARY TRAFFIC CONTROL PLANPuget Sound EnergyTraffic Control Supervisor:Safaa Al NeemaCard No. IS 6 100072Card Exp. 10/10/2028Safaa.alneema@pse.com(425)398-6077NSIGN SPACINGMPH60/6545/5535/403025"X"1000'500'350'200'100'CHANNELIZATIONDEVICE SPACINGMPH55/7035/4525/30TAPER403020TANGENT806040MFP25000916 6.00' @ 7.50%6.00' @ 7.50%4.00 ' @ 0 .75%0.75%0.84%8.37%4.15%4.00' @ 1.50%4.00 ' @ 0 .75% 0.77%7.46' @ 2.01%3.96' @ 5.31%1.61 ' @ 3 .72%1.49' @ 2.02%5.86' @ 1.54%3.55' @ 1.97% 6.8 4 ' @ 1 . 0 2 %6.96' @ 3.16%FL, BR EL 32.72STA 3+16.42OFF 18.60FL, BR EL 32.75STA 3+12.99OFF 20.65LD EL 33.17STA 3+19.77OFF 24.18LD EL 33.20STA 3+16.34OFF 26.24LD EL 33.23STA 3+21.83OFF 27.61LD EL 33.26STA 3+18.40OFF 29.67FL EL 32.92STA 3+09.12OFF 27.96FL EL 32.66STA 3+23.45OFF 17.85MATCH EXTOCEL 33.42FL EL 32.97STA 3+09.03OFF 34.46MATCH EXBOC EL 33.07STA 3+06.03OFF 34.46MATCH EXEL 32.75STA 3+23.45OFF 14.85MATCH EXTOCEL 33.38MATCH EXTOCEL 33.10MATCH EXSW EL 33.17STA 3+23.33OFF 21.90SW EL 33.26STA 3+23.31OFF 27.76SW EL 33.30STA 3+17.01OFF 30.50SW EL 33.53STA 3+17.09OFF 34.45MATCH EX2.01%4.00' @ 1.50%FL, PC EL 32.94STA 3+09.03OFF 29.77FL, PT EL 32.69STA 3+20.57OFF 17.84SW EL 33.49STA 3+28.31OFF 27.78MATCH EXSW EL 33.37STA 3+28.33OFF 21.93MATCH EX5.00' @ 4.00%5.85' @ 2.05%5.00' @ 4.60%0+001+002+003+004+005+006+007+007+33CR1ADA CURB RAMP GRADING PLAN1OF% REVIEW SUBMITTALIF NOT, SCALE ACCORDINGLYONE INCH AT FULL SCALE.PUGET SOUND ENERGYDUPONT PIPE REPLACEMENT444 PARK AVE NCITY OF RENTON, WA1100719 2nd Avenue, Suite 200 • Seattle, WA 98104Ph: 206.394.3700EACH ADA ELEMENT SHALL MEET APPLICABLECROSS SLOPE AND RUNNING SLOPE ADASTANDARDS. ELEMENTS NOTED ON PLANS AREFOR REFERENCE ONLY.GRADING NOTES:RAMPLANDINGSIDEWALKCROSSWALKRLSWCWADA ELEMENT:LEGEND:BR-BOTTOM OF RAMPEL-ELEVATIONEX-EXISTINGFL -FLOWLINELD -LANDINGOFF-OFFSETPC -POINT OF CURVATUREPT -POINT OF TANGENCYSTA-STATIONSW -SIDEWALKTOC-TOP OF CURBGENERAL NOTES:1.2.3.4.5.6.7.APPROXIMATE SURVEYED EXISTING ELEVATIONS ARE SHOWN.CONTRACTOR SHALL CONSTRUCT RAMPS AND SIDEWALK TO MEETALL ADA SLOPE REQUIREMENTS IF FIELD ELEVATIONS DO NOT MATCHTHOSE SHOWN.RADIUS CALLOUTS ARE TO FACE OF CURB.RAMP GRADING POINTS REPRESENT ONE METHOD OF MEETING RAMPADA STANDARDS. IT IS THE RESPONSIBILITY OF THE CONTRACTOR TOMAKE FIELD ADJUSTMENTS AS NECESSARY TO ENSURE RAMPS MEETALL ADA REQUIREMENTS.CONTRACTOR SHALL PROVIDE SURVEY STAKING TO THE LEVEL OFSURVEY ACCURACY NECESSARY TO SUPPORT THE CONSTRUCTIONOF SIDEWALK, CURBS, CURB RAMPS AND RELATED PROJECTELEMENTS. TRADITIONAL SURVEY AND STAKING METHODS SHALL BESUPPLEMENTED IN THE FIELD BY THE CONTRACTOR THROUGH THEUSE OF A CONTRACTOR-SUPPLIED, CALIBRATED, 4-FOOT LONG"SMART" LEVEL TO DIGITALLY MEASURE SLOPES.EXISTING STORM STRUCTURES AND UTILITY STRUCTURES ARESHOWN FOR REFERENCE.RAMP SLOPES ON THIS SHEET ARE CALCULATED FROM THE LANDINGTO FRONT EDGE OF DETECTABLE WARNING SURFACE. CONSTRUCTDEPRESSED CURB AND GUTTER IN FRONT OF DETECTABLE WARNINGSURFACE PER CITY OF RENTON STD PLAN - 101.INSTALL INLET PROTECTION ON ALL DOWNHILL CATCH BASINS WITHIN200 FEET OF THE WORK AREA PER WSDOT STD PLAN I-40.20-00.CONSTRUCTION NOTES:CONSTRUCT CEMENT CONC. CURB RAMP TYPE PERPENDICULAR APER WSDOT STD PLAN F-40.15-04CEMENT CONC. TRAFFIC CURB AND GUTTER PER CITY OF RENTONSTD PLAN - 101DETECTABLE WARNING SURFACE PER WSDOT STD PLAN F-45.10-051230ALIGNMENT PLANSCALE IN FEET3060PT #1003PT #1002PROJECT CONTROLPT #10021003NORTHINGEASTING181843.691302444.90ELEV32.05DESCRIPTIONFOUND MONUMENT181856.371301712.3532.75HORIZONTAL DATUM FOR THIS SURVEY IS NAD 1983(11),WASHINGTON STATE PLANE NORTH ZONE COORDINATE SYSTEM,U.S. SURVEY FEET, BASED ON THE RTK GPS MEASUREMENTSCONSTRAINED TO THE WASHINGTON STATE REFERENCE NETWORK.HORIZONTAL DATUM:VERTICAL DATUM FOR THIS SURVEY IS NAVD 88 BASED ON THEWASHINGTON STATE REFERENCE NETWORK (WSRN) WITHVERIFICATION TIES TO THE FOLLOWING MONUMENTS PUBLISHED BYWSDOT.POINT DESIGNATION: WSDOT #IS17165ELEVATION: 35.715VERTICAL DATUM:0ADA CURB RAMP PLANSCALE IN FEET24RLSWSWCWROWROW R=11.5'LEGEND:HMA CL 12 IN. PG 64-22EX FACE OF GUTTEREX FACE OF CURBEX BACK OF CURBEX SIDEWALKEX SIDEWALK SAWCUTEX LANDSCAPINGNE 5TH STPARK AVE N PARK AVE N NE 5TH STWORK AREA123CEMENT CONC. SIDEWALK PER CITY OFRENTON STD PLAN - 102DETECTABLE WARNING SURFACERAMP EXTENTSPROTECT EXISTINGCATCH BASIN IN PLACE2'FOUND MONUMENTBEGIN2END2SW6/20/25 Owner / Developer Contact Info officeATTN: THIS SKETCH NOT TO BE RELIED UPON FOR EXACT LOCATION OF EXISTING FACILITIES CALL 811 2 BUSINESS DAYS BEFORE YOU DIG For contacts below dial 1-888-CALL PSE (225-5773) 109158896 108654051 108654050 GAS PROJECT PHASE Notification #Order # Main Retire SVC Retire SAP Superior Service/Meter Service/Meter HP Svc/MSA Dis. Reg. / FT Ind. MSA Ind. Service Service/Meter Service/Meter LEGEND FIELD NOTES: FIELD DESIGNER: CELL: EMAIL: CONSTRUCTION QUESTIONS: PROJECT CONTACT INFORMATION: CONST MANAGER: CELL: EMAIL: PROJ MANAGER: CELL: EMAIL: FOR MAIN DESIGNS REALIGNMENTS - FIELD DESIGNER SHALL BE CONTACTED: BILLING QUESTIONS: 425-429-5821 JEFF MCCOY jeff.mccoy@pse.com 206-255-4824 STEVE MELLINGER steve.mellinger@pse.com 425-429-5821 JEFF MCCOY jeff.mccoy@pse.com SAP BATCH YEAR & FOOTAGE ACTUAL LENGTH OF RETIREMENT MATERIAL RETIRED ORIGINAL JOB ORIGINAL YEAR PROPOSED LENGTH OF RETIREMENT SIZE OF RETIRED MAIN Cell Phone: "Locates Required" "Flagging Required" Yes No Yes No E-Mail: Manager: Project Manager Contact Information: JEFF MCCOY 425-429-5821 jeff.mccoy@pse.com 109156864HOLE HOG/BORE TABLE CALLOUT LOCATION DEPTH LENGTH BP1 START BP2 END BP3 START BP4 END BP5 START BP6 END BP7 START BP8 END BP9 START BP10 END BP11 START BP12 END BP13 START BP14 END BP15 START BP16 END BP17 START BP18 END BP19 START BP20 END BP21 START BP22 END BP23 START BP24 END STOP TIME START TIME GAS MAIN PRESSURE & TESTING TESTED BY GAS MAIN INSTALLATION/RETIREMENT SOAP AIR NITROGEN WATER SOAP AIR NITROGEN WATER STOP TIME START TIME TESTED BY TEST RESULTS P F TESTED BY PSE PRESSURE CONTROL, SEE FORM 1928 P F Type/Work ManufacturerPipe Size Type Est Length Act Lgth TYPE TEST / / DATE OFF PRESSURE DATE ON DATE OFF TYPE TEST PRESSURE SYS MAOPDESIGN PRESS DATE ON 2023 02/18 TEST RESULTS / / / / / / Verify Testing Requirements, Chart vs Gauge GOS 2525.3300 sec. 5, Table 5-1 and sec. 5.5 GASSED UP PIPELINE PIPE SEGMENT FOREMAN'SDATENAME INSTALL 2"MPE 5' INSTALL 2"MPE 205' RETIRE 2"PE-A 194' 60 45 PSIG Inspected Steel and PE pipe per GOS 2450.1400 and 2450.1500 Reviewed and complied with all construction notes. Recorded all required information on the as-built per GOS 2500.1700. Completed post installation inspection per GOS 2525.1200 and 2525.2700. Left the work area in a clean and safe condition. FITTER'S CHECKLIST Foreman's Name (printed) ___________________________________ Foreman's Signature________________________________________ Company: __________________________ Date ______________ (CHECK BOX TO CONFIRM COMPLETION) 4680 06/11 DESIGNED BY UTILITIES CONTACT PHONE# COUNTY 1/4 SEC OP MAP Emer Sect GAS WK CTR PLAT MAP JOINT FACILITIES ARRANGEMENTS DRAWN BY CHECKED BY APPROVED BY CP APPROVAL MAPPING SCALE PAGE ENGR - GAS FUNCTION PROJECT MGR PERMITREAL ESTATE/EASEMENT 2 1 REV# 3 DATE DESCRIPTIONBY CONTACT PHONE NO DATE Drawing Number SAP Sup Order Nbr PC APPROVAL J.MCCOY 425-429-5821 . J.MCCOY 425-429-5821 . R.BECK 425-424-6483 . D.DAO 425-424-6426 . M.JANSSON 425-466-9047 . B.JOHNSON 206-571-8519 11/18/24 ... N/A RENTON DUPONT PIPE REPLACEMENT 444 PARK AVE N RENTON, WA 98057 PUGET SOUND ENERGY 109156864 109156864 1" = 20'-0"1/3 KING 498 SYSGGIN SW 08-23-05 E 204.080 207.082 N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A 10915686412012824 STANDARD GAS CONSTRUCTION NOTES: 1.FIELD LOCATE ALL UNDERGROUND UTILITIES. EXCAVATOR TO CALL "ONE-CALL" TWO WORKING DAYS PRIOR TO CONSTRUCTION, IN WESTERN WASHINGTON CALL: 1-800-424-5555. OR CALL NATIONWIDE: 811 2.NOTIFY APPROPRIATE PERMITTING AGENCY PRIOR TO JOB START (SEE PERMIT REQUIREMENTS). 3.ALL CONSTRUCTION IS TO CONFORM TO PSE GAS OPERATING STANDARDS AND GAS FIELD PROCEDURES. 4.EROSION AND SEDIMENT CONTROL SHALL BE PER PSE STANDARD PRACTICE 0150.3200 TECHNIQUES FOR TEMPORARY EROSION AND SEDIMENT CONTROL AND ANY ADDITIONAL LOCAL JURISDICTION REQUIREMENTS. 5.NOTIFY PROPERTY OWNERS ADJACENT TO PROPOSED CONSTRUCTION ACTIVITIES A MINIMUM OF TWO WORKING DAYS PRIOR TO BEGINNING CONSTRUCTION. USE iSi TO DISTRIBUTE FLYERS IF JOB IS LARGE, OTHERWISE HAND DELIVER FLYERS BE SURE TO INCLUDE THE LIST OF FREQUENTLY ASKED QUESTIONS AND INFORMATION ABOUT THE OPPORTUNITY TO PURCHASE AN EXCESS FLOW VALVE WHEN THEIR SERVICE IS INSTALLED OR REPLACED PER GAS OPERATING STANDARD 2550.1600. ALLOW ADEQUATE TIME FOR CUSTOMER DECISION AND RESPONSE. 6.ANY CHANGE IN ROUTE, PIPE SIZE/TYPE, TIE-IN METHOD OR ADDITIONAL MAIN FOOTAGE MUST BE APPROVED BY THE APPROPRIATE PSE ENGINEER OR PSE REPRESENTATIVE. 7.COMPLETE "PIPE CONDITION REPORT" ON ALL METALLIC PSE FACILITIES. CHECK BOX ON REPORT FOR WIRE BOX (TEST LEAD) INSTALLATION. 8.PIPELINE MARKERS AND WARNING SIGNS SHALL BE INSTALLED AND RECORDED BY THE CONTRACTOR PER PSE GAS OPERATING STANDARD 2525.2500. 9.INSTALL MAIN VALVES OUT OF TRAFFIC WHERE POSSIBLE. VALVE MARKERS SHALL BE INSTALLED AND RECORDED BY THE CONTRACTOR PER PSE GAS OPERATING STANDARD 2525.2600 FOR ALL HP VALVES IF THE LOCATION IS NOT READILY ACCESSIBLE, AND FOR ALL VALVES WHERE PERSISTENT SNOWFALL MAY OBSCURE THE VALVE BOX. 10.TO PREVENT ACCIDENTAL OVERPRESSURE OF ADJOINING SYSTEMS, NO TWO MAINS SHALL BE CONNECTED EXCEPT AS SHOWN ON THIS DESIGN UNLESS APPROVED BY APPROPRIATE PSE ENGINEER OR PSE REPRESENTATIVE. 11.SYSTEM MAOP DENOTED BY: SYSTEM MAOP = 45 PSIG 12.GAUGE AND MONITOR USE OF ALL STOPPERS TO ENSURE ADEQUATE FEED. 13.RESTORE ALL DRIVEWAYS SUBJECT TO OPEN CUT TO ORIGINAL OR BETTER CONDITION. 14.PURGE POINTS TO BE INSTALLED PER PSE GAS OPERATING STANDARDS 2525.3400. 15.MAINS AND SERVICES SHALL BE TESTED AND PURGED PER PSE GAS OPERATING STANDARDS 2525.3300 AND 2525.3400. 16.IF METALLIC PIPE IS INVOLVED, COORDINATE INSTALLATION WITH CP TECH. ____B.JOHNSON__________________________, PHONE___206-571-8519___________. 17.NOTE ALL ACTUAL FOOTAGE, LOCATION AND MATERIAL CHANGES ON THE AS-BUILT IN RED. ( ') DENOTES FOOTAGE BETWEEN FITTINGS. 18.EXCESS FLOW VALVE TO BE INSTALLED ON ALL NEW RESIDENTIAL SERVICES PER GOS 2500.2200. (RECORD ALL INFORMATION ON D-4 CARD) STANDARD IP & LP GAS REPLACEMENT CONSTRUCTION NOTES 1.NOTIFY GAS CUSTOMERS, OR DISTRIBUTE FLYER #1443 A MINIMUM OF TWO WORKING DAYS PRIOR TO A PLANNED OUTAGE. 2.INSTALL ONE POUND ANODE FOR EVERY 1000' OF LOCATING WIRE. INSTALL ANODE AND TEST LEAD WIRES PER PSE GAS OPERATING STANDARD 2525.2300. 3.MAINTAIN CATHODIC PROTECTION FOR STEEL MAINS BY THE USE OF CONTINUITY BONDS OR OTHER MEANS DETERMINED BY THE PSE CORROSION ENGINEER PER PSE GAS OPERATING STANDARD 2600.1300. 4.INSTALL ANODES AND TEST LEAD WIRES AS REQUIRED PER PSE GAS FIELD PROCEDURES 4515.1000 AND 4515.1020 AND PSE GAS OPERATING STANDARD 2600.1200. TEST LEAD WIRES ARE REQUIRED ON ALL TRANSITION FITTINGS. 5.INSTALL CURB VALVE AT PROPERTY LINE OR 5/8" PE WHIP AT MAIN (AS REQUIRED) ON NEW AND EXISTING SERVICES PER PSE GAS OPERATING STANDARD 2550.1600. 6.REFER TO PSE GAS OPERATING STANDARD 2525.1700 FOR MAIN AND SERVICE COVER REQUIREMENTS. 7.MAINS AND SERVICES SHALL BE TESTED AND PURGED PER PSE GAS OPERATING STANDARDS 2525.3300 AND 2525.3400 AND PSE GAS FIELD PROCEDURE 4700.1500. 8.PROJECT MANAGER TO MAKE AN ACTIVE SERVICE RUN IMMEDIATELY PRIOR TO STARTING CONSTRUCTION. 9.INSTALL REPLACEMENT MAINS PER PSE GAS OPERATING STANDARD 2525.2100. 10.PLUG ENDS OF DEACTIVATED OR INSERTED MAINS AND SERVICES IN ACCORDANCE WITH PSE GAS OPERATING STANDARDS 2525.2100 AND 2525.3600. 11.REMOVE OR RENDER INOPERABLE DEACTIVATED VALVES ON CASING WHERE MPE PIPE IS INSERTED. 12.INSIDE METER SETS SHALL BE MOVED OUTSIDE WHENEVER POSSIBLE OR SET REGULATORS AND VENTS OUTSIDE PER PSE GAS OPERATING STANDARDS 2575.2300 AND 2550.1700. 13.REPLACE EXISTING ACTIVE SERVICES PER PSE GAS OPERATING STANDARDS 2525.2100 AND 2575.2300. 14.REPLACE ALL "NO RECORD" SERVICES AND 1-1/8" PE SERVICES INSTALLED PRIOR TO 1985. 15.ACTIVE SERVICES TO BE REPLACED DENOTED BY: 16.MAINS AND SERVICES SHALL BE CONSTRUCTED IN ACCORDANCE WITH 2525.1200. 17. PIPE SQUEEZING SHALL BE DONE IN ACCORDANCE WITH GOS 2525.1200 AND GAS FIELD PROCEDURES 4700.1300 AND 4700.1310. 18.WHEN INSTALLING, DEACTIVATING, REPAIRING, OR OTHERWISE MODIFYING A PIPELINE THAT IS LOCATED WITHIN 200 FEET OF ANY ACTIVE REGULATING STATION, PRESSURE RELIEF AND LIMITING DEVICE, OR SINGLE SERVICE FARM TAP WHERE GAS SYSTEM ENGINEERING REVIEW AND APPROVAL IS REQUIRED PER GAS OPERATING STANDARDS. SEE REVIEW DOCUMENTS, PROVIDED BY ENGINEERING. 19.FIELD TO VERIFY THAT ALL PROPER SERVICE ACTIONS (FOLLOWING THE KEY TO SERVICE ACTION LEGEND) HAVE BEEN ACCOUNTED FOR PER THE "SERVICE CHECKLIST". IF A RISER IS FOUND IN THE FIELD AND WASN'T ACCOUNTED FOR, FIELD PERSONNEL SHALL CONFIRM WHETHER THE RISER IS AN ABANDONED OR IDLE RISER: 19.1 IF IT IS AN ABANDONED RISER, CONTACT THE POINT DESK TO REQUEST GFR TO REMOVE IT. 19.2 IF IT IS AN IDLE RISER, REPORT THE RISER TO THE PROJECT MANAGER SO THAT THE PROJECT MANAGER MAY CONFIRM WITH THE CUSTOMER WHETHER THEY WOULD LIKE TO KEEP THE SERVICE AND RISER. THE PROJECT MANAGER MAY INSTRUCT TO TEST AND TIE THE SERVICE IF THE CUSTOMER WANTS GAS OR DOESN'T PROVIDE PSE A RESPONSE IN A TIMELY MANNER. ### 1.ALL DUPONT AND STW PIPES SHALL BE RETIRED PER SCOPE OF WORK. 2.NOTIFY PROJECT MANAGER IF ADDITIONAL DUPONT AND/OR STW MATERIALS ARE FOUND DURING CONSTRUCTION, INCLUDING AT OR BEYOND THE CONNECTION POINTS. ### T&T ### KEY TO SERVICE ACTION T&T C&C RWM ### ### ### ### METHOD OF CONSTRUCTION ARTERIAL MFP25000916 THIS SKETCH NOT TO BE RELIED UPON FOR EXACT LOCATION OF EXISTING FACILITIES CALL 811 2 BUSINESS DAYS BEFORE YOU DIG For contacts below dial 1-888-CALL PSE (225-5773) Cell Phone: "Locates Required" "Flagging Required" Yes No Yes No E-Mail: Manager: Project Manager Contact Information: JEFF MCCOY 425-429-5821 jeff.mccoy@pse.com Inspected Steel and PE pipe per GOS 2450.1400 and 2450.1500 Reviewed and complied with all construction notes. Recorded all required information on the as-built per GOS 2500.1700. Completed post installation inspection per GOS 2525.1200 and 2525.2700. Left the work area in a clean and safe condition. FITTER'S CHECKLIST Foreman's Name (printed) ___________________________________ Foreman's Signature________________________________________ Company: __________________________ Date ______________ (CHECK BOX TO CONFIRM COMPLETION) 4680 06/11 DESIGNED BY UTILITIES CONTACT PHONE# COUNTY 1/4 SEC OP MAP Emer Sect GAS WK CTR PLAT MAP JOINT FACILITIES ARRANGEMENTS DRAWN BY CHECKED BY APPROVED BY CP APPROVAL MAPPING SCALE PAGE ENGR - GAS FUNCTION PROJECT MGR PERMITREAL ESTATE/EASEMENT 2 1 REV# 3 DATE DESCRIPTIONBY CONTACT PHONE NO DATE Drawing Number SAP Sup Order Nbr PC APPROVAL J.MCCOY 425-429-5821 . J.MCCOY 425-429-5821 . R.BECK 425-424-6483 . D.DAO 425-424-6426 . M.JANSSON 425-466-9047 . B.JOHNSON 206-571-8519 11/18/24 ... N/A RENTON DUPONT PIPE REPLACEMENT 444 PARK AVE N RENTON, WA 98057 PUGET SOUND ENERGY 109156864 109156864 N.T.S.2/3 KING 498 SYSGGIN SW 08-23-05 E 204.080 207.082 N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A GAS OPERATIONS MAP SCALE: N.T.S. MFP25000916 N 5TH ST GARDEN AVE NPARK AVE N12" STW HP 22'S 783165 1978 8" STW HP 9'W31 195712" STW HP 17'W783165 19784" STW HP 14'S 889003406 2011 12" STW HP 21'S 783165 19782" STW IP 22'W6974 19642" STW IP 9'S 6974 1964 8" STW HP 9'W31 19575/8" MPE IP 222'S 1999 19'S,49'W NR43'W10'W43'W,19'S 10'W22'S38'S 14'S,9'W////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////// P 2" STW IP 28'S 802-050 1979 2" STW IP 21'W 6974 19642" STW IP 22'W6974 1964 29'S (____)1218 T&T(____)500(___')225'EIP GAS FLOW IP GAS FLOW IP GAS FLOW IP GAS FLOW12" STW HP 22'S 783165 1978 2" PE-A IP 28'S 802-050 1979 1 1/4" MPE IP 223'E 2008T&T(____)420////////////// 12" STW HP 22'S 2" STW IP 28'S 2" PE-A IP 28'S(___')(___')30'ETHIS SKETCH NOT TO BE RELIED UPON FOR EXACT LOCATION OF EXISTING FACILITIES CALL 811 2 BUSINESS DAYS BEFORE YOU DIG For contacts below dial 1-888-CALL PSE (225-5773) PLAN VIEW SCALE: 1" = 20'-0" Cell Phone: "Locates Required" "Flagging Required" Yes No Yes No E-Mail: Manager: Project Manager Contact Information: JEFF MCCOY 425-429-5821 jeff.mccoy@pse.com Inspected Steel and PE pipe per GOS 2450.1400 and 2450.1500 Reviewed and complied with all construction notes. Recorded all required information on the as-built per GOS 2500.1700. Completed post installation inspection per GOS 2525.1200 and 2525.2700. Left the work area in a clean and safe condition. FITTER'S CHECKLIST Foreman's Name (printed) ___________________________________ Foreman's Signature________________________________________ Company: __________________________ Date ______________ (CHECK BOX TO CONFIRM COMPLETION) 4680 06/11 DESIGNED BY UTILITIES CONTACT PHONE# COUNTY 1/4 SEC OP MAP Emer Sect GAS WK CTR PLAT MAP JOINT FACILITIES ARRANGEMENTS DRAWN BY CHECKED BY APPROVED BY CP APPROVAL MAPPING SCALE PAGE ENGR - GAS FUNCTION PROJECT MGR PERMITREAL ESTATE/EASEMENT 2 1 REV# 3 DATE DESCRIPTIONBY CONTACT PHONE NO DATE Drawing Number SAP Sup Order Nbr PC APPROVAL J.MCCOY 425-429-5821 . J.MCCOY 425-429-5821 . R.BECK 425-424-6483 . D.DAO 425-424-6426 . M.JANSSON 425-466-9047 . B.JOHNSON 206-571-8519 11/18/24 ... N/A RENTON DUPONT PIPE REPLACEMENT 444 PARK AVE N RENTON, WA 98057 PUGET SOUND ENERGY 109156864 109156864 1" = 20'-0"3/3 KING 498 SYSGGIN SW 08-23-05 E 204.080 207.082 N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/APARK AVE NN 5TH ST(ARTERIAL)GARDEN AVE NPARK AVE N(ARTERIAL)GARDEN AVE NScale: N.T.S. TIE-IN DETAIL1 1 - MFP25000916 RESTORATION PER CITY OF RENTON STANDARDS BOM for WO: ITEM QTY DESCRIPTION PART NO. 2 CP TEST BOX PLUS TEST LEAD, SLEEVE, AND WELD METAL MOLD 5000307 2 CAP 2" MDPE 5200649 1 ELBOW 2" X 90 MDPE 6000484 1 ELL 2" 90 DEGREE WELD STD 6000500 210 PIPE 2" COIL MED DENSITY 7000261 20 PIPE 2" STRAIGHT MED DENSITY 7000263 2 CP COPPER ADAPTER SLEEVE 7600540 1 STOP-B/O 2" X 150 PSIG, MUELLER H-17160 7600741 1 TEE-PUNCH, SERV 1/2" X 5/8" X 125 PSIG, PE OUTLET, 1/4" CUTTER 7800575 1 TRANSITION, 2" X 0.154" X SDR-11, GR B, WELD X FUSE 7800809 2 WELD METAL CATHODIC MOLD 8500080 20 CP WIRE #10 COPPER 8500930 210 WIRE #14 COPPER TRACER 8500940 MFP25000916