Loading...
HomeMy WebLinkAboutAPPROVED - F_Lindbergh HS Pedestrian Ramp_20250314_v1g. 8-1-1 Call before you D or 1-800-424-5555 UNDERGROUND SERVICE (USA) RSCALE 1"=80' 40 80 1600 CITY OF RENTON IN COMPLIANCE WITH CITY OF RENTON STANDARDS 43667 NSTATE O F WASHI N G TON R EGIST E R E D P R O F E SSIONAL E N G I N EER O S B O CAJA.DLAREJ C2 4 0 0 0 4 5 0 CX01 Sheet List Table Sheet Number Sheet Title C001 OVERALL SITE PLAN C101 DEMOLITION PLAN C110 TESC DETAILS C201 CIVIL SITE PLAN C210 SITE DETAILS OVERALL SITE PLAN 1"=80' DEVELOPMENT ENGINEERING njanders 03/14/2025 CF IP IP1 5 . 6 ' 3' 25.5' S W S W S W S W S W S W S W S W SWSWSWSWSW SW SW SW SW SW SW SW SW SW SW SW SW SW SW SW SW SW SW SWSWSWSW S W S W S W S W S W SW SAWCUT AND REMOVE EXISTING ASPHALT INLET PROTECTION (TYP) SEE DETAIL CFSW REMOVE EXISTING CONCRETE INSTALL STRAW WATTLES SEE DETAIL REMOVE EXISTING CURB SAWCUT TO NEAREST CONCRETE JOINT C110 4 C110 3 INLET PROTECTION TEMP CONSTRUCTION FENCINGCF IP g. 8-1-1 Call before you D or 1-800-424-5555 UNDERGROUND SERVICE (USA) RSCALE 1"=2' 1 2 40 LEGEND SAWCUT LINE REMOVE CURBING REMOVE ASPHALT PAVEMENT REMOVE CONCRETE PAVEMENT STRAW WATTLE SWSW CITY OF RENTON IN COMPLIANCE WITH CITY OF RENTON STANDARDS 43667 NSTATE O F WASHI N G TON R EGIST E R E D P R O F E SSIONAL E N G I N EER O S B O CAJA.DLAREJ C2 4 0 0 0 4 5 0 DEMOLITION PLAN a 0' DEVELOPMENT ENGINEERING njanders 03/14/2025 1.STRAW ROLL INSTALLATION REQUIRES THE PLACEMENT AND SECURE STAKING OF THE ROLL IN A TRENCH, 3" x 5" (75-125mm) DEEP, DUG ON CONTOUR. 2.RUNOFF MUST NOT BE ALLOWED TO RUN UNDER OR AROUND ROLL. 3.FOR ASPHALT OR CONCRETE APPLICATIONS, STRAW WATTLE SHALL BE LAID ON TOP OF PAVEMENT AND HELD IN PLACE AS NEEDED WITH SAND BAGS AND ADJUSTED AS NECESSARY AS PHASING OR FIELD CONDITIONS CHANGE. ROLL SPACING DEPENDS ON SOIL TYPE AND SLOPE STEEPNESS STRAW ROLLS MUST BE PLACED ALONG SLOPE CONTOURS 3'-4' (1.2m) 10 ' - 2 5 ' (3- 8 m ) ADJACENT ROLLS SHALL TIGHTLY ABUT SEDIMENT, ORGANIC MATTER, AND NATIVE SEEDS ARE CAPTURED BEHIND THE ROLLS LIVE STAKE 1" x 1" STAKE 8"-10" DIA. (200-250mm) NOTES: 3"-5" (75-125mm) OVERFLOW (TO BYPASS PEAK STORM VOLUMES) SEDIMENT ACCUMULATION GEOTEXTILE FABRIC ADAPTER SKIRT RETRIEVAL STRAP INLET PROTECTION NOTE: FILTERS SHALL BE INSPECTED AFTER EACH STORM EVENT AND CLEANED OR REPLACES WHEN 1/3 FULL. 48"48" CITY OF RENTON IN COMPLIANCE WITH CITY OF RENTON STANDARDS 43667 NSTATE O F WASHI N G TON R EGIST E R E D P R O F E SSIONAL E N G I N EER O S B O CAJA.DLAREJ C2 4 0 0 0 4 5 0 Inlet Protection 3NTS Straw Wattle 4NTS 6' F E N C E LINE POST (TYP) 2.375 INCH 0.D. TOP RAIL 1.666 INCH O.D. STRETCHER BAR BRACE RAIL AND CABLE 1.666 INCH O.D. TRUSS ROD 3/8" DIA W/ TENSION DEVICE TENSION WIRE CONCRETE BLOCK STD WGT GALVANIZED CORNER POST 5/8" WIRE ROPE PROVIDE SECURE END ATTACHMENT AT CORNER AND GATE POSTS AND PROVIDE RUNNING ATTACHMENT AT LINE POSTS AND NEAR CENTER OF EACH FENCE PANEL Construction Fence 8NTS Not Used 9NTS Not Used 1NTS Not Used 5NTS TESC DETAILS Not Used 6NTS Not Used 2NTS Not Used 7NTS DEVELOPMENT ENGINEERING njanders 03/14/2025 1 6 . 3 ' 3' 25.5' REPLACE EXISTING CONCRETE SEE DETAIL TRUNCATED DOMES SEE DETAIL ASPHALT REPLACEMENT AND PATCHING SEE DETAIL LOWER EXISTING CATCH BASIN AS NEEDED 41 3 412 TC 412.91 BC 412.41 TC 412.98 BC 412.48 TC 412.69 BC 412.19 TC 412.58 BC 412.08 411.51 (EX) 412.74 (EX) 412.54 (EX) 412.44 (EX) TC 413.23 (EX) BC 412.73 (EX) TC 412.11 (EX) BC 411.61 (EX) SINGLE DIRECTION CURB RAMP SEE DETAIL VERTICAL CURB SEE DETAIL TC 412.40 (EX) BC 411.90 (EX) 411.69 (EX) C210 1 C210 2 C210 3 C210 5 C210 4 g. 8-1-1 Call before you D or 1-800-424-5555 UNDERGROUND SERVICE (USA) RSCALE 1"=2' 1 2 40 LEGEND ASPHALT PAVEMENT CONCRETE PAVEMENT CONCRETE CURB CONTOUR SPOT ELEVATION 109.36 109 TC 109.86 BC 109.36 CITY OF RENTON IN COMPLIANCE WITH CITY OF RENTON STANDARDS 43667 NSTATE O F WASHI N G TON R EGIST E R E D P R O F E SSIONAL E N G I N EER O S B O CAJA.DLAREJ C2 4 0 0 0 4 5 0 CIVIL SITE PLAN a 0' DEVELOPMENT ENGINEERING njanders 03/14/2025 CITY OF RENTON IN COMPLIANCE WITH CITY OF RENTON STANDARDS 43667 NSTATE O F WASHI N G TON R EGIST E R E D P R O F E SSIONAL E N G I N EER O S B O CAJA.DLAREJ C2 4 0 0 0 4 5 0 Single Direction Curb Ramp 1NTS Detectable Warning Surface 2NTS SITE DETAILS COMPACTED SUBGRADE (MIN 95% MAXIMUM DRY DENSITY) CRUSHED BASE COURSE (1-1/4" MINUS) CRUSHED SURFACING TOP COURSE (5/8" MINUS) CEMENT CONCRETE PAVEMENT 6" 2" 4" FLUSH WITH ADJACENT SURFACES ON ALL SIDES FOR CONCRETE FINISH AND JOINTING, SEE LANDSCAPE PLANS NOTES: 1.DEPTHS ARE COMPACTED THICKNESS 2.WHERE PERMEABLE BALLAST IS USED FOR CONSTRUCTION ACCESS AND STAGING, SOME RUTTING AND DISTURBANCE OF THE SURFACE MAY OCCUR. THE CONTRACTOR SHALL REMOVE AFFECTED AREAS AND REPLACE THEM WITH PROPERLY COMPACTED CRUSHED ROCK PRIOR TO FINAL SURFACING. WHERE PERMEABLE BALLAST IS USED, NO CRUSHED SURFACING BASE COURSE WILL BE REQUIRED UNLESS DIRECTED BY THE GEOTECHNICAL ENGINEER. SEE SHEET C3.06 #4 BARS AT 12" O.C. EACH WAY 2" CLR (TYP) NOTES: 1.SEE LANDSCAPE ARCHITECTURAL PLANS FOR CONCRETE SCORING AND JOINTING. 2.CEMENT CONCRETE SHALL BE CLASS 4000 NOTES: DEPTHS ARE COMPACTED THICKNESS HMA CLASS 1/2" COMPACTED CRUSHED SURFACING TOP COURSE COMPACTED CRUSHED SURFACING BASE COURSE 12" SAWCUT TACK AND MATCH EX ASPHALT FULL DEPTH EX UNDISTURBED PAVEMENT SUB-BASE MUST BE COMPACTED TO 95% MAX DENSITY PER ASTM D 1557 EXISTING ASPHALT COMPACTED STRUCTURAL FILL SUB-BASE (OR EXISTING SUBGRADE) PER GEOTECHNICAL ENGINEER 4" 2" 4" 12 " M I N 3" 4" 12 " M I N 2" 4" 12 " M I N HE A V Y D U T Y ST A N D A R D D U T Y WA L K / T R A C K 5.5" 6.5" 6" PAVEMENT FACE OF CURB R1" R0.5" FINISH GRADE 8.25" 16 " 0.5" TOP OF CURB AT DRIVEWAY APPROACH NOTE: CONTRACTOR SHALL CONFORM TO WSDOT SPEC. 8-04.3 Concrete Pavement 3NTS Asphalt Pavement 4NTS Vertical Curb 5NTS DEVELOPMENT ENGINEERING njanders 03/14/2025