Loading...
HomeMy WebLinkAboutR-419905O� rn I O I 0 LU VJ z W 0 Q G w z z O z LU rr 16+95 "0 NE SUNSET BLVD FOUND CONIC MON W/ I 17+00 BRASS DISK IN CASE, DOWN 0.5' NE 10TH ST STA 16+94.92 G sy \N\\ I - o�� STA 19+98.48, 28.56' RT 1-inn 1 OF CURB RAMP STA 50+38.24, 15.90' LT 2C430 C430 of CURB_ _ ___ JEFFERSON AYE NE 50+00 _ - � (COMMERCIAL ACCESS) 49+47 _ _ - 9�� 20+00 PCC STA. 50+68.59, 18.00' RT CENTERLINE INTERSECTION .0- STA 50+00.00 JEFFERSON AVE NE -- (COMMERCIAL ACCESS) _=80°50'30" PCC STA. 50+59.88, 16.02' RT- p v n STA 20+00.00 NE 10TH ST I L=24.69' PCC STA. 50+50.98. 14.00' RT n STA 20+36.13, 24.73' RT 1-0'4 j OF CURB RAMP IN C430 R=17.50' F I I mP9��Gio _ A 'Z�oy STA 20+69.99, 28.75' LT BUS SHELTER, FOOTING �I I Q v 0 + 01 a CN I� 5.9' N � O v 6 = N I0 U �- C- i cn � W ,- Z cn J I R43.0' Q STA. 21 +53.10, 41.52' LT- CDrAD N BW R60.0' o J R75.0' '. o / o X DROPERTY N 1N (TYP) 173, om Q STA. 21 +69.47, 41.52' LT o Cn U � Cfl O BW C6 a ¢ R PROPERTY �j X / LINE (TYP) o �� + o cn N N I CD o� o p II Ln M m STA. 21 +97.73, 43.52' LT p Ln I BW X OCD PCC STA. 22+27.15, 23.00' LT Pam no A--99°01'4; m 9 L=37.16' CD N R=21.50' 0 � M� b n CDm O Cn q v . N -X U / �� �IDI 7 STA 22+55.54, 35.62' LT ono /X oo�. C430 OF CURB RAMPCD CD ag I so / CD CENTERLINE INTERSECTIONo�� I STA. 22+80.33 NE 10TH ST = n (-, / T� X CONSTRUCTION RECORD DRAWINGS m� i m THESE RECORD DOCUMENTS HAVE BEEN F151 A. b2+yy.b /, 1 b.U1 K I PCC STA. 83+09.38, 15.50' RT' PC STA. 83+19.07, 13.00RT _ PCC STA. 84+36.70, 9.00 RT PCC STA. 84+27.98, 11.00' RT APT STA. 84+19.26. 13.00' RT i soN p�E NE 0o JEFFER AC�ESSi N �605'o�E __R20:0' (TYP) SEE NOTE 6 PREPARED FROM THE CONTRACTOR'S REDLINED MARK-UPS OF THE CONSTRUCTION Michael Ruether (THE I Dakota Simurdak (THE CONTRACTOR OF RECORD) HEREBY CERTIFY SURVEYOR OF RECORD) HEREBY CERTIFY E DOCUMENTS. THE ENGINEER REVIEWING THESE THAT THE FIELD MEASUREMENT INFORMATION THAT THE SURVEY INFORMATION SHOWN ON 0- CnX RECORD DRAWINGS HAS NOT WITNESSED ALL SHOWN ON THESE RECORD DRAWINGS THESE RECORD DRAWINGS ACCURATELY THE ELEMENTS OF CONSTRUCTION AND IS THE REFLECTS THE FIELD CONDITIONS REFLECTS THE FIELD CONDITIONS AS OF / NOT RESPONSIBLE FOR ERRORS OR N EOMISSIONS IN DATA OR CERTIFY THE AS OF 10/29/2024. 10/29/2024. ACCURACY OF THE INFORMATION PROVIDED x /�i��iae�l�uet�iew x Dakota �issruwcial BY THE CONTRACTOR'S AS -BUILT REDLINES. O X CENTERLINE INTERSECTION STA 53+55.54 JEFFERSON AVE NE (COMMERCIAL ACCESS) = STA 80+00.00' JEFFERSON AVE NE (RESIDENTIAL ACCESS) 6 STA 53+13.66, 9.44' LT C430 OF CURB RAMP 5 - STA 53+13.83, 14.13' RT C430 OF CURB RAMP PCC STA. 53+02.11, 16.02' RT 52+00 _ PCC STA. 52+93.40, 18.00' RT �- - - _ 53+00 5 STA 52+85.55, 18.00' RT - �3O OF DRIVEWAY \ STA 51+97.04, 213.55' RT STA 83+02.67, 17.78' RT � OF CURB RAMP STA. 83+15.18, 7.34' LT STA. 83+45.82, 13.00' LT 80+00 53+81 G- N CC STA. 80+29.60, 20.52' RT I %\ I I 1 7 STA 53+29.51, 60.65 RT n o � O f (o Cn 00 I� PC STA. 81+22.87, 40.38' RT 10/14/2024 1 CIVIL CONSTRUCTION PERMIT CMK 10/19/21 TJE SURVEYED: ScaF vERncAL: raw saes 2 CIVIL CONSTRUCTION PERMIT RESUBMITTAL CMK 12 20 21 TJE DESIGNED:AS SHOWN HORIZONTAL NAD 19e3/1991 3 CIVIL CONSTRUCTION PERMIT RESUBMITTAL CMK 02 18 22 TJE CMK 4 CIVIL CONSTRUCTION PERMIT REVISION CB 06 17 22 TJE DRAWN: CC, JYL 5 GRADING, STORM, AND PSE UPDATE CB 12 20 23 TJE CHECKED: ONE INCH DATUM CB AT FULL SCALE IF NOT ONE INCH NO. REVISION BY DATE AP P R APPROVED: SCALE ACCORDINGLY TJE 1601 5th Avenue, Suite 1600 Seattle, WA 98101 206.622.5822 www.kpff.com ki CITY OF RENTON Planning/Building/Public Works Dept. NOTES 1. REFER TO LANDSCAPE PLANS FOR HORIZONTAL CONTROL OF SURFACE LO IMPROVEMENTS OVER STRUCTURE AND SITE FURNISHINGS. LO 'T^ u / 2. REFER TO ARCHITECTURAL PLANS FOR BUILDING LOCATION AND LAYOUT. O DIMENSIONS PROVIDED TO BUILDING FACE ARE INTENDED FOR LAYOUT OF O T SITE ELEMENTS ONLY AND SHALL NOT BE USED TO LAYOUT THE BUILDING. N 3. ALL DIMENSIONS, STATIONS AND OFFSETS ARE TO FACE OF CURB, FACE OF U WALL, OR EDGE OF PAVEMENT, UNLESS OTHERWISE NOTED. 4. SITE ELEMENTS SHALL BE EITHER PARALLEL OR PERPENDICULAR TO THE BUILDING FACE, UNLESS OTHERWISE NOTED. 5. BIORETENTION PLANTER DIMENSIONS ARE SHOWN TO INSIDE PLANTER EDGES. SEE SHEET C700 FOR PLANTER DESIGN INFORMATION. 6. PARKING LANE CURB BULB RADII SHALL BE 20' UNLESS NOTED OTHERWISE. I co c0 7. REFER TO C620 TYPICAL SECTIONS FOR HORIZONTAL LAYOUT OF I T IMPROVEMENTS IN THE RIGHT-OF-WAY. O O -, LEGEND N - - - - PROPERTY LINE J BUILDING LINE STREET CENTERLINE CEMENT CONCRETE TRAFFIC CURB AND GUTTER O co PAVEMENT EDGE p O vn I CONCRETE PAVEMENT N 0 10' 20' 40' R-419905 1 inch = 20 feet z W IN COMPLIANCE WITH CITY OF RENTON STANDARDS 0 a C� w z D RENTON SUNSET GARDENS 10/14/2024 z FlELOBOOK: 2900 NE 10TH ST, RENTON, WA 98056 z PAGE: O DRAWING NO: C100 W HORIZONTAL CONTROL PLAN SHE` 05 �`44 �