Loading...
HomeMy WebLinkAboutR-419926DocuSign Envelope ID: 6EECF5B6-602A-4E4A-B436-A317AA638878 DocuSign Envelope ID: 3B1B34D3-7EOA-476C-ADB3-4329FFEOC108 DocuSign Envelope ID: 6EECF5B6-602A-4E4A-B436-A317AA638878 c/ Z W r) rr G W v / Z Z:) c/ / Z O I— Z W rr SEE STANDARD PLANS 110, 110.1, 110.2, AND 111 FOR PAVEMENT RESTORATION REQUIREMENTS SURFACE RESTORATION AS SPECIFIED IN CONTRACT DOCUMENTS 2"MIN. -- EXISTING PAVEMENT SURFACE 6"MIN., SEE NOTE4 ANEAT LINE TRENCH / "CRUSHED SURFACING TOP COURSE" PER WSDOT STD. SPEC 9-03.9(3), COMPACTED TO 95 % OF MAXIMUM DENSITY "CRUSHED SURFACING TOP COURSE"PER WSDOT STD. SPEC 9-03.9(3), "BANK RUN GRAVEL FOR TRENCH BACKFILL" PER WSDOT STD. SPEC 9-03.19, OR "GRAVEL BORROW" PER WSDOT STD. SPEC 9-03.140), COMPACTED TO 95% OF MAXIMUM DENSITY BENCH AS NEEDED FOR SHORING SYSTEM WHEN DEPTH IS 4' OR GREATER J PIPE PIPE ZONE BEDDING AND BACKFILL PER STD. PLANS 220.00 AND 220.10 — i SEE NOTE 1 UNPAVED AREAS I PAVED AREAS NOTES: i. SEE WSDOT/APWA STANDARD SPECIFICATIONS SECTION 2-09.4 FOR MEASUREMENT OF TRENCH WIDTH. 2. EXCAVATIONS OVER 4' DEEP SHALL COMPLY WITH THE SAFETY STANDARD DESCRIBED IN CHAPTER 295-155 PART N OF THE WAC. 3. MAXIMUM BACKFILL DEPTH ABOVE PIPE SHALL NOT BE EXCEEDED, AS DETERMINED BY PIPE MANUFACTURER. 4. IN PAVED AREAS, IF PIPE HAS LESS THAN V OF COVER, USE "CRUSHED SURFACING TOP COURSE" FOR THE ENTIRE BACKFILL DEPTH ABOVE PIPE ZONE, 5. SEE CONSTRUCTION PLANS FOR SPECIFIC PROJECT REQUIREMENTS. STD. PLAN - 220.20 R 1� DEPARTMENT PUBLIC WORKS TYPICAL TRENCH AND BACKFILL RR D GAZ 9/28/2018 1 � DATE 45 A C700 �M�, 3/4" FLAT FACE GOTHIC a❑ y 9" DIA +i " goo o � C3 STORM O 4- 13000 A ❑❑ DIA 10-1/2" DIA (2) 3/8"-16 SS SOCKET HEAD CAP 15"DIA (1) OPEN PICKHOLE 1" SCREW (ALLENHEAD) WNVSHRS ON A B" DIA BOLT CIRCLE CAST IRON FRAME AND COVER, SEE NOTE 3 8" CLASS "B" ASPHALT, SEE NOTE CLEANOUT RISER, SEE NOTE 2 PAVED AREA (TYP.) EXTEND CLEANOUT RISER 2" ABOVE DESIGN PONDING ELEVATION OR PER PLAN - DESIGN PONDING ELEVATION - 4" COMPACTED SAND OR n GRAVEL BACKFILL FOR DRAINS PER WSDOT 9-03.12(4) CLEANOUT RISER, SOIL TIGHT 45° BEND SEE NOTE 2 - �7 8-11�3/7166" D�IIABp� COVER SECTION FERNCO GASKETED QUIK CAP OR SIMILAR `4"STREAMBEDCOBBLES PER WSDOT 9-03.11(2) III III III n llll WYE =1I1=1 —I SOIL TIGHT � � — � — � — — COUPLER I_IIII1�= UNDERDRAIN, FOOTING DRAIN COLLECTOR, OR ROOF DRAIN COLLECTOR —III—III—I PIPE, SEE NOTE 1 CLEANOUT RISER LOCATED WITHIN BIORETENTION PONDING AREA TO OVERFLOW STRUCTURE OR STORM MAIN MECHANICAL PLUG OR CONTINUED CONNECTION TYPICAL CLEANOUT CONFIGURATION NOTES: 1. DIAMETER TO BE 6-INCHES MINIMUM PRIVATE, 8-INCHES MINIMUM PUBLIC. UNDERDRAIN PIPE PER STD. PLAN 262.10. 2. CLEANOUT RISER SHALL BE SAME MATERIAL AS CONNECTED UNDERDRAIN, FOOTING DRAIN COLLECTOR, OR ROOF DRAIN COLLECTOR PIPE. 3. FRAME AND COVER SHALL BE EJ PRODUCTS 3675Z1 PT AND 3675APT OR APPROVED EQUAL. COVER TO BE LOCKING WITH ALLEN HEAD BOLT, MARKED "STORM" OR "DRAIN". 4. FOR CLEANOUTS FULLY OR PARTIALLY WITHIN UNPAVED AREAS OUTSIDE OF BIORETENTION PONDING AREA, POUR 8" THICK, 2'x2' SQUARE CONCRETE COLLAR AROUND FRAME. CONCRETE COLLAR SHALL HAVE A MINIMUM COMPRESSIVE STRENGTH OF 3,000 PSI. GENERAL NOTES: 1. CLEANOUTS FOR UNDERDRAIN, FOOTING DRAIN COLLECTOR, AND ROOF DRAIN COLLECTOR PIPES SHALL BE INSTALLED AT A MINIMUM OF EVERY 100 FEET, AT EVERY 90 DEGREE OR SECOND 45 DEGREE BEND, AT THE END OF EVERY COLLECTOR PIPE, AND AT EACH END OF AN UNDERDRAIN PIPE NOT CONNECTED TO AN OVERFLOW STRUCTURE. CLEANOUTS SHALL BE INSTALLED TO ALLOW FOR MAINTENANCE ACCESS TO ALL PIPES. 2. ALL FITTINGS SHALL BE SOIL TIGHT. 3. CLEANOUT RISER SHALL BE LOCATED OUTSIDE OF BIORETENTION PONDING WHERE POSSIBLE. 4. CLEANOUTS SHALL NOT BE LOCATED WITHIN THE STREET TRAVEL LANE, UNLESS OTHERWISE APPROVED BY THE CITY. UNLESS OTHERWISE NOTED, DRAWING 15 NOT TO SCALE (NTS) STD. PLAN - 226.00 4 PUBLIC WORKS[1,11)81Vned08by: DEPARTMENT STORM SYSTEM CLEANOUT actin Pastucha $/13/20 VASOF"�j'�u1 x, 988¢q,9D... DATE J F_ W I O I`rJ U (n I cn ck m cn m I N O O) /n o J / Q u) O) In 0 ¢ UI O CD c O) C-7 N N c O (/7 c O C O) Un O r- O O O N O O (D) O O N CD O / O U` O Z N CD / U U / E J O H- I aN /af / x I / x x N N I U m T~ CONSTRUCTION RECORD DRAWINGS m� 00 THESE RECORD DOCUMENTS HAVE BEEN Michael Ruether (TH E I Dakota Simurdak (THE " PREPARED FROM THE CONTRACTOR'S CONTRACTOR OF RECORD) HEREBY CERTIFY SURVEYOR OF RECORD) HEREBY CERTIFY co REDLINED MARK-UPS OF THE CONSTRUCTION E DOCUMENTS. THE ENGINEER REVIEWING THESE THAT THE FIELD MEASUREMENT INFORMATION THAT THE SURVEY INFORMATION SHOWN ON N RECORD DRAWINGS HAS NOT WITNESSED ALL SHOWN ON THESE RECORD DRAWINGS THESE RECORD DRAWINGS ACCURATELY THE ELEMENTS OF CONSTRUCTION AND IS ACCURATELY REFLECTS THE FIELD CONDITIONS REFLECTS THE FIELD CONDITIONS AS OF NOT RESPONSIBLE FOR ERRORS OR N OMISSIONS IN DATA OR CERTIFY THE AS OF 10/29/2024. 10/29/2024. ACCURACY OF THE INFORMATION PROVIDED x���ad leaetlew x Dalota fl�raehl BY THE CONTRACTORS AS -BUILT REDLINES. CD x 1 CIVIL CONSTRUCTION PERMIT 2 CIVIL CONSTRUCTION PERMIT RESUBMITTAL 3 CIVIL CONSTRUCTION PERMIT RESUBMITTAL 4 CIVIL CONSTRUCTION PERMIT REVISION 5 GRADING, STORM, AND PSE UPDATE NO. REVISION 24" ' r I L BOLT -DOWN SLOT, gq• SEE DETAIL AND 2 1/2" DIA, HOLE NOTE 1 1 11/4' 20" A OQ 5/8" I O000�o I T � I E SLOT DETAIL L SEE NOTE 1 J m 3" TOP R26-, SEE NOTE 2 � DO��OO��DOOO�O�QOO�O � T ISOMETRIC 4 3/4�1 1/21 /2" L SECTION B 1 5/8" MAX. R39% SEE NOTE 2 SECTION A R_� PUBLIC WORKS DEPARTMENT NOTES: 1. BOLT -DOWN CAPABILITY IS REQUIRED ON ALL FRAMES, GRATES, AND COVERS, UNLESS OTHERWISE SPECIFIED. PROVIDE TWO HOLES IN THE FRAME THAT ARE VERTICALLY ALIGNED WITH THE GRATE OR COVER SLOTS. THE FRAME SHALL ACCEPT THE 5/8"-11 NC x 2" ALLEN HEAD CAP SCREW BY BEING TAPPED, OR OTHER APPROVED MECHANISM. LOCATION OF BOLT -DOWN HOLES VARIES BY MANUFACTURER. 2. ALTERNATIVE REINFORCING DESIGNS ARE ACCEPTABLE IN LIEU OF THE RIB DESIGN. 3. REFER TO STANDARD SPECIFICATION 9-05.15(2) FOR ADDITIONAL REQUIREMENTS. 4. FOR FRAME DETAILS, SEE CITY OF RENTON STANDARD PLAN 204.00. UNLESS OTHERWISE NOTED, DRAWING IS NOT TO SCALE (NTS) STD. PLAN - 204.10 D: RECTANGULAR SOLID METAL COVER GAZ 9/28/2018 I DATE C M K 10/ 19/21 TJE suRvEYED: C M K 12 20 21 TJE DESIGNED: cMK CMK 02 18 22 TJE CB 06 17 22 TJE DRAWN: DC, JYL CB 12 20 23 TJE CHECKED: cEI BY DATE AP P R I APPROVED: TJE :45 r3'4� IN C700 �WAS&N?;�� 0 42'I61 - • Call 811 �o��S��rSTEgVg", SIGNAL E� ® two business days before you dig 10/14/2024 SCALE:VERTi_ AS SHOWN HORIZONTAL: NAD 1983/1991 ONE INCH DATUM AT FULL SCALE IF NOT ONE INCH SCALE ACCORDINGLY 1601 5th Avenue, Suite 1600 Seattle, WA 98101 206.622.5822 www.kpff.com ki CITY OF RENTON Planning/Building/Public Works Dept. Ln LO O O T N 1 L J T N a J T N R-419926 z w IN COMPLIANCE WITH CITY OF RENTON STANDARDS 0 ra� V w v! Z RENTON SUNSET GARDENS 10/14/2024 z z FlELDBOOK: 2900 NE 10TH ST, RENTON, WA 98056 PAGE: O DRAWING NO: C731 W STANDARD STORM DRAINAGE DETAILS SHE: 26 OF`44 0�