Loading...
HomeMy WebLinkAboutR-419937Ld 120 VOLT ELECTRICAL OUTLET FOR HEAT TAPE. INSTALL HEAT TAPE ' Q } FOR FREEZE PROTECTION CENTER BACKFLOW Of PREVENTER IN Ld O REDUCED PRESSURE ENCLOSURE a BACKFLOW ASSEMBLY (RPBA) b 3" MIN. � o I 3" MIN. 3" MIN. INSULATED ENCLOSUR "HOT BOX" OR EQUAL 3/8" X 4" ANCHOR BOLTS PER = MANUFACTURER O f 3" MIN. CONCRETE SLAB z UNION : FINISHED N GRADE FINISHED GRAD N rZ DRAIN TE z SEE NOTE 4 6" MINIMUM SLEEVE FREE DRAINING (TYP.) GRAVEL z CONNECT TO N WATER METER IMMEDIATELY ADJACENT TO RPBA FLOW - INSTALLED W/ APP'D. TO OWNERS ELECTRICAL PANEL. FRONT VIEW MATERIAL PER UPC DIRECT BURIAL OR IN RIGID METER SIDE (SIZE AS REQ.) CONDUIT PER ELECTRICAL SIDE VIEW PERMIT REQUIREMENTS. NOTES: 1. ALL REDUCED PRESSURE BACKFLOW ASSEMBLIES (RPBA's) MUST BE LISTED ON LATEST LIST OF "BACKFLOW PREVENTION ASSEMBLIES APPROVED FOR INSTALLATION IN WASHINGTON STATE", PUBLISHED BY STATE OF WASHINGTON DEPARTMENT OF HEALTH. 2. THE OWNER/APPLICANT MUST OBTAIN A SEPARATE CITY OF RENTON PLUMBING PERMIT FOR THE INSPECTION OF THE INSTALLATION OF THE RPBA AND PIPING. THE OWNER SHALL FURNISH, INSTALL AND MAINTAIN THE RPBA AND ALL PIPING AND APPURTENANCES SHOWN ON THIS PLAN. 3. THE RPBA MUST BE TESTED BY A STATE CERTIFIED BACKFLOW ASSEMBLY TESTER AFTER ITS INITIAL INSTALLATION, AFTER REPAIRS AND ANNUALLY THEREAFTER AT OWNER'S EXPENSE. A COPY OF THE TEST REPORT SHALL BE SENT OR FAXED TO CITY OF RENTON WATER UTILITY ENGINEERING DEPT., ATTN: WATER UTILITY CROSS -CONNECTION CONTROL SPECIALSIT, FAX NO. 425-430-7241. 4. DRAIN SHALL BE SIZED IN ACCORDANCE WITH AWWA CROSS CONNECTION CONTROL MANUAL STANDARDS 3" DRAIN FOR 1" OR SMALLER RPBA's, 4" DRAIN FOR 1.5" TO 2" RPBA's, 6" FOR 3" RPBA's. 5. RPBA AND ENCLOSURE SHALL BE LOCATED ON PRIVATE PROPERTY AND AS NEAR AS POSSIBLE TO THE WATER METER. t T ° STD. PLAN - 350.2 n PUBLIC WORKS REDUCED PRESSURE BACKFLOW + DEPARTMENT ASSEMBLY IN HOT BOX MARCH 2O10 C800, C812 TESTING DETAIL t 1 O Fr w I NEW WATER LINE oM EXISTING WATER LINE 00 O cn tl Q EXISTING TEE, DEAD END LINE, CAP OR PLUG \ DO NOT DISTURB BLOCKING m VERTICAL CROSS (MJxFL) FOR POLYPIGGING 1-BLIND FLANGE ON TOP WITH 2"TAP & 2"PLUG Q 1-BLIND FLANGE ON BOTTOM N 1-PLUG(MJ) W/2"TAP & 2" BLOW -OFF % TEMP. BLOCK FINAL CONNECTION DETAIL j NEW WATER LINE o1 o EXIST. WATER LINE O o � Q U I CD O c a a U AFTER ALL TESTING, CLEANING BY POLYPIG AND DISINFECTION, REMOVE TEMP. BLOCK & BLOW -OFF & CONNECT n TO EXISTING WATER LINE WITH SLEEVE (MJ) AND D.I. SPOOLS o FINAL CONNECTION BY CITY FORCES N w CD O CD O O O N 6� O Cn CD CD /, e► PUBLIC WORKS �•`O DEPARTMENT STD. PLAN - 300.5 CONNECTION TO WATER MAIN EXISTING TEE OR END LINE CAP 4 MARCH 2O10 O N� N 801, C�1� C835 CD ;m U I / U E o� Qm /Q / I X / CD z CD w mco X CONSTRUCTION RECORD DRAWINGS m� m THESE RECORD DOCUMENTS HAVE BEEN PLAN ---------------- I I I I I I I 24"I MINI I I A I a I a ®®® m CID ®0 OD ° I ® ® I I I I < I \I I G I b ELEVATION MIN Aouu 3" T010 " DCVA STD. PLAN - 350.1 Sht. 1 of 2 PUBLIC WORKS APPROVED: DEPARTMENT VAULT INSTALLATION DOMESTIC AND IRRIGATION SERVICES DATE TEMPORARY 2" GALVANIZED PIPE AND 2" GATE VALVE FINISHED GRADE ELEVATION INSTALL 2" PLUG ON TOP BLIND FLANGE AFTER REMOVAL OF POLYPIG 3 FT MIN. COVER (10-INCH DIAMETER AND UNDER) 4 FT MIN. COVER (12-INCH DIAMETER AND OVER) I \ NEW WATER MAIN POLYPIG 1 i> VERTICAL CROSS FOR POLYPIGGING STATION SIZE OF VERTICAL CROSS SHALL BE THE SAME AS SIZE OF MAIN LINE VERTICAL CROSS (MJ X FL) ONE BLIND FLANGE ON TOP OF CROSS WITH 2" TAP & 2" TEMPORARY BLOW -OFF ASSEMBLY (REMOVE BLOW -OFF ASSEMBLY AND INSTALL 2" PLUG AFTER REMOVAL OF CLEANING 'POLY -PIG") ONE BLIND FLANGE ON BOTTOM OF CROSS ONE PLUG (MJ) ON END OF CROSS CONCRETE BLOCKING ALL DEBRIS AND POLYPIGS SHALL BE REMOVED FROM SUMP OF VERTICAL CROSS BEFORE DISINFECTION OF NEW WATER MAIN STD. PLAN - 300.6 PUBLIC WORKS POLY PIG STATION FOR CLEANING OF "'•` DEPARTMENT WATER MAINS p$ MARCH 2O10 I Michael Ruether (THE I Dakota S imurdak (THE PREPARED FROM THE CONTRACTOR'S CONTRACTOR OF RECORD) HEREBY CERTIFY SURVEYOR OF RECORD) HEREBY CERTIFY REDLINED MARK-UPS OF THE CONSTRUCTION E DOCUMENTS. THE ENGINEER REVIEWING THESE THAT THE FIELD MEASUREMENT INFORMATION THAT THE SURVEY INFORMATION SHOWN ON 1 CIVIL CONSTRUCTION PERMIT X RECORD DRAWINGS HAS NOT WITNESSED ALL SHOWN ON THESE RECORD DRAWINGS THESE RECORD DRAWINGS ACCURATELY 2 CIVIL CONSTRUCTION PERMIT RESUBMITTAL THE ELEMENTS OF CONSTRUCTION AND IS ACCURATELY REFLECTS THE FIELD CONDITIONS REFLECTS THE FIELD CONDITIONS AS OF / 3 CIVIL CONSTRUCTION PERMIT RESUBMITTAL NOT RESPONSIBLE FOR ERRORS OR AS OF 10/29/2024. 10/29/2024. 4 CIVIL CONSTRUCTION PERMIT REVISION OMISSIONS IN DATA OR CERTIFY THE 5 GRADING, STORM, AND PSE UPDATE ACCURACY OF THE INFORMATION PROVIDED �i1 o l c x i��iae uet�e� x �% o �! a (/ kta UImaj-ala BY THE CONTRACTOR'S AS -BUILT REDLINES. N0. REVISION O X C834, C835 NOTES: 1. THE DCVA MUST BE LISTED ON THE LATEST VERSION OF "BACKFLOW ASSEMBLIES APPROVED FOR INSTALLATION IN WASHINGTON STATE", PUBLISHED BY THE STATE OF WASHINGTON DEPARTMENT OF HEALTH. 2. THE DCVA MUST BE TESTED BY A WASHINGTON STATE CERTIFIED BACKFLOW ASSEMBLY TESTER UPON INSTALLATION AND ANNUALLY THEREAFTER. ASSEMBLY TO BE MAINTAINED BY PROPERTY OWNER. A COPY OF THE TEST REPORT SHALL BE SENT TO THE CITY OF RENTON WATER UTILITY CROSS CONNECTION CONTROL SPECIALIST, FAX 425-430-7241, EMAIL MHOLTE@RENTONWA.GOV. 3. VAULTS SHALL NOT BE INSTALLED IN AREAS WITH VEHICLE TRAFFIC. 4. VAULT AND HATCH MODELS ARE PROVIDED AS REFERENCE. SHOP DRAWINGS SHALL BE SUBMITTED TO THE CITY FOR APPROVAL. 5. TEE AND GATE VALVE REQUIRED ON MAIN. 6. PROVIDE MINIMUM 2' OF LEVEL, UNOBSTRUCTED AREA AROUND HATCHES. 7. EACH VALVE SHALL BE MARKED WITH MODEL NUMBER WITH DESIGNATION OF RESILIENT SEAT: SUCH AS "RS" OR "R", WHICH MUST BE CAST, MOLDED, OR AFFIXED ONTO THE BODY OR BONNET OF THE VALVE. ALL FERROUS BODIED VALVES SHALL BE COATED WITH A MINIMUM OF 4 MILS OF EPDXY OR EQUIVALENT POLYMERIZED COATING. MATERIALS ODOUBLE CHECK VALVE ASSEMBLY OB PIPE SUPPORT O ADAPTER O WATER MAIN OE WALL FLANGE OF CONCRETE VAULT OG DRAIN OH ACCESS HATCH OI LADDER 10 GRAVEL LINE -SIZED WASHINGTON STATE -APPROVED DCVA WITH TWO (2) RESILIENT -SEATED SHUT-OFF VALVES AND FOUR (4) RESILIENT -SEATED TEST COCKS, DCVA SHALL BE INSTALLED EQUIDISTANT FROM THE ENDS OF THE CONCRETE VAULT, TWO (2) VALVE SUPERVISORY SWITCHES (ONE PER VALVE) PER RRFA REQUIREMENTS ADJUSTABLE PIPE SADDLE SUPPORT, GRINNELL FIG 264 OR EQUAL, WITH BASE, BOLTED TO FLOOR RESTRAINED FLANGE ADAPTER, EBAA IRON SERIES 2100 MEGAFLANGE OR EQUAL CLASS 52 DI PIPE (PExFL) WITH RESTRAINED JOINTS MIDSPAN PIPE RESTRAINT WITH CONCRETE BLOCKING PER STD PLAN 350.7, SEAL PIPE PENETRATIONS WITH WATER -TIGHT GROUT OLDCASTLE PRECAST VAULT, MODEL NUMBERS PER TABLE ABOVE, OR EQUAL MINIMUM 6" PVC FLOOR DRAIN, SLOPE TO STORM DRAIN OR DAYLIGHT TO DRAINAGE DITCH WITH WIRE MESH RODENT SCREEN AT DRAIN OUTLET, SEAL PIPE PENETRATION WITH WATER -TIGHT GROUT TWO LOCKING HINGED ALUMINUM DOORS, TRAFFIC -RATED, WITH SLIP -RESISTANT TREATMENT, MARKED "WATER", LW PRODUCTS MODEL NUMBERS PER TABLE ABOVE, OR EQUAL GALVANIZED STEEL LADDER SECURED TO VAULT PER STD PLAN 350.8 FOUNDATION GRAVEL PER WSDOT STANDARD SPECIFICATIONS, 12" MINIMUM ALL DIRECTIONS VAULT MODEL NUMBERS DCVA SIZE VAULT BASE PIECE CENTER PIECE TOP PIECE ACCESS HATCH 3" 644-LA NO.644-B N/A NO.64-352P HHD-1C 4" 575-LA NO.575-BL N/A NO.57-2-33F HHD-1C 6" 577-LA NO.588-BL N/A NO.57-2-33F HHD-1C 8" 4484-LA NO.4484-BL NO.4484-ML NO.4484-TL-2-332P HHD-2D 10" 5106-LA NO.5106-BL NO.5106-ML NO.5106-TL3-332 HHD-2D �� " STD. PLAN - 350.1 Sht. 2 of 2 .} PUBLIC WORKS 3 TO 10 DCVA APPROVED: DEPARTMENT VAULT INSTALLATION DOMESTIC AND IRRIGATION SERVICES DATE PROFILE 24" MIN MATERIALS OA WALL FLANGE MIDSPAN PIPE RESTRAINT, EBAA IRON SERIES 110OSDB MEGALUG OR EQUAL, WRAP WITH POLYETHYLENE ENCASEMENT PRIOR TO PLACEMENT OF CONCRETE BLOCKING CONCRETE THRUST BLOCKING, CAST -IN -PLACE CONCRETE (MINIMUM 3,000 PSI), TO BE SIZED BY DESIGN OB BLOCKING ENGINEER (MINIMUM 24N24N6") (C CORE DRILL (O.D. +2") VAULT IF KNOCKOUTS ARE NOT PROVIDED, SEAL PIPE PENETRATION WITH PIPE PENETRATION WATER -TIGHT GROUT OD GRAVEL FOUNDATION GRAVEL PER WSDOT STANDARD SPECIFICATIONS, 12" MINIMUM ALL DIRECTIONS It PUBLIC WORKS CONCRETE BLOCKING DEPARTMENT ADJACENT TO VAULT CMK 10/19/21 TJE S" CMK 12 20 21 TJE DESIGN . CMK CMK 02 18 22 TJE CB 06 17 22 TJE DRA": DC, JYL CB 12 20 23 TJE CHECKED: CEI BY DATE APPR APPROVED: TJE STD. PLAN - 370.4 Call 811 �0_?O si( • ® two business days before you dig SC&E: VERTICAL: NAVD 1 AS SHOWN HORIZONTAL: NAD tee/teat ONE INCH DATUM AT FULL SCALE IF NOT ONE INCH SCALE ACCORDINGLY DATE 10/14/2024 C800`,C812 MARKER MARKER o I TWO LANE ROAD OFFSET MARKER TO INDICATE WHICH SIDE OF STREET HYDRANT IS ON (4" FROM DOTS OR PAINTED LINE) MARKER I I . FOUR LANE ROAD OFFSET MARKER TO INDICATE WHICH SIDE OF STREET HYDRANT IS ON (4" FROM DOTS OR PAINTED LANE DIVIDER) HYDRANT MARKERS 4' RAISED PAVMENT MARKER TYPE 88 AB STIMSONITE TWO-WAY (BLUE) MARKER o o� ON SIDE STREETS WHERE THE HYDRANT IS WITHIN 20' OF A MAIN TRAVELED STREET, THE MARKER IS TO BE INSTALLED ON THAT MAIN STREET MARKER C e FIVE LANE ROAD OFFSET MARKER TO INDICATE WHICH SIDE OF STREET HYDRANT IS ON (4" FROM DOTS OR PAINTED LANE DIVIDER) STD. PLAN - 310.3 • PUBLIC WORKS DEPARTMENT HYDRANT MARKER LAYOUT �FN,To� MARCH 2010 PLAN F------ -T- ------ I I I I-16" -I I 1 I I I WHINGE ACCESS HATCH HINGE�I 1 (SEE NOTES 4 & 5) I I I I I I I I I I I I e L--------1-------- . 4 . 4 FIRST STEP - 8" TO 12" BELOW TOP OF COVER CONCRETE MECHANICAL ANCHOR BOLT, GALVANIZED OR STAINLESS STEEL (TYP.) SIDE RAIL AND BRACKET 1%" x K" GALVANIZED STEEL (TYP.) RUNG, NO. 8 DEFORMED REINFORCING BAR CONFORMING TO ASTM A615 4" MIN PVC DRAIN TO DAYLIGHT OR STORM DRAIN SYSTEM, PROFILE 1" MAX 3" MIN o d Li 0 12" (TYP.) 0 d WIRE MESH RODENT SCREEN OVER DRAIN NOTES: 1. VAULTS SHALL ONLY BE INSTALLED IN SHOULDERS, SIDEWALKS, OR LANDSCAPED AREAS. VAULTS SHALL NOT BE INSTALLED IN AREAS WITH VEHICULAR TRAFFIC. VAULT COVER SHALL READ "WATER". 2. LADDER TO BE SECURED TO VAULT WALL ATTHREE LOCATIONS: TOP, MIDDLE, AND BOTTOM. 3. ALL LADDER PARTS TO BE GALVANIZED CONFORMING TO ASTM A123. 4. ACCESS HATCH SHALL BE LOCKING ALUMINUM DOUBLE DOORS, LW PRODUCTS CO. MODEL HHD-1C OR HHD-2D AS REQUIRED, RATED FOR H-30 LOADING WITH A SLIP RESISTANT TREATMENT AS FOLLOWS: THERMION, SAFTRAX TH604 GRADE #2 MODERATE TEXTURE SUPNOT, GRIP PLATE GRADE 2 (MEDIUM) STEEL HARSCO IKG, MEBAC#1 GRATING PACIFIC, ALGRIP SLIP -RESISTANT FLOOR PLATE 5. HATCHES SHALL INCLUDE RECESSED PADLOCK HASP SIZED FOR CITY OF RENTON WATER UTILITY PADLOCKS (CONTACT LW PRODUCTS). 6. LADDER -UP ATTACHMENT REQUIRED ON ALL VAULT LADDERS, BILCO LADDERUP TYPE LU-2. STD. PLAN - 370.5 PUBLIC WORKS APPROVED: DEPARTMENT VAULT LADDER DATE 1601 5th Avenue, Suite 1600 Seattle, WA 98101 206.622.5822 www.kpff.com Aoftk CITY OF 1;%R] RENTON VASOF Planning/Building/Public Works Dept. C800, C812, C813 r7 �OO R-419937 Ui ) LO C) C) N 1 LJ H H W-419908 w IN COMPLIANCE WITH CITY OF RENTON STANDARDS 0 CC a 0 w 0 Z RENTON SUNSET GARDENS 10/14/2024 2900 NE 10TH ST, RENTON, WA 98056 z FlELDBOOK: PAGE OI__ DRAIMNG NO: C832 W STANDARD WATER DETAILS SHE. 37 '44 10�