Loading...
HomeMy WebLinkAboutS-419903NOTES .2 V Z T W p N Q 0— G rr I— W V ) z z O z LU rr os��y r�qy S �SS °csy S SS 0o sz�° o o � 92 O 0 STA 17+76.73, 2.01LT Z 4 CONNECT TO EX 12" STUB C835 C832 PER COR STD 300.5 BY COR SEE NOTE 2, (1)-12" SLEEVE, (MJ)' 12" DI SPOOLS AS REQUIRED RO A I NE F �^ ri1�2J SUNSET BLVD I F F sls. 4G c+a J s J zo N Q F° II sa°mT UPON ACCEPTANCE OF NEW �= �q MAIN, REMOVE EX VERTICAL i nQa� CROSS, BLOWOFF PIPING, AND BLOWOFF ASSEMBLY w � w) a- ° CUD D� II mo iZZc` O� ASZ I I I s V) 12" W m '— C811 Z � I z m STA 17+89.72, 1.85' LT (1)-45° BEND, (MJ) (1)—THRUST BLOCK STA 17+92.92, 1.42' RT (1)-45° BEND, (MJ) (1)—THRUST BLOCK UD a U 2" ASPHALT GRINDCD CD I 00 & OVERLAY (TYP) uTZE 2 Cn ASPHALT PAVEMENT ( ) C6. Cn SAWCUT (TYP) TYP � O I5 Y CENTERLINE RAISED 1 + 0 PAVEMENT MARKERS PER N (n CD WSDOT STD M-20.50-02 / I z � J i -o <n x s � xaS y y C N C O1 N cn I CD � c N Q m Wo / � U Cn N Of O ROW O] R a Q COO UD nz° X x a ° c LLJ <n (n MATCH LINE - SEE SHEET MATCH LINE -SEE SHEET 3 MATCHLINE: SEE SHEET C800 Q� o LCJ O Cn Q O CDX1 O N / 6) CD CT t� O J o I O U N Cn I � o O J O m O O Q N I X U / :_ o� "' QCn / I X / CD z CD C-D w C�)/ TQc X CONSTRUCTION RECORD DRAWINGS m� I m THESE RECORD DOCUMENTS HAVE BEEN PREPARED FROM THE CONTRACTOR'S Michael Ruether (THE I Dakota Simurdak (THE CONTRACTOR OF RECORD) HEREBY CERTIFY SURVEYOR OF RECORD) HEREBY CERTIFY REDLINED MARK-UPS OF THE CONSTRUCTION J a m DOCUMENTS. THE ENGINEER REVIEWING THESE THAT THE FIELD MEASUREMENT INFORMATION THAT THE SURVEY INFORMATION SHOWN ON 1 CIVIL CONSTRUCTION PERMIT RECORD DRAWINGS HAS NOT WITNESSED ALL SHOWN ON THESE RECORD DRAWINGS THESE RECORD DRAWINGS ACCURATELY 2 CIVIL CONSTRUCTION PERMIT RESUBMITTAL X THE ELEMENTS OF CONSTRUCTION AND IS ACCURATELY REFLECTS THE FIELD CONDITIONS REFLECTS THE FIELD CONDITIONS AS OF / 3 CIVIL CONSTRUCTION PERMIT RESUBMITTAL NOT RESPONSIBLE FOR ERRORS OR AS OF 10/29/2024. 10/29/2024. 4 CIVIL CONSTRUCTION PERMIT REVISION OMISSIONS IN DATA OR CERTIFY THE 5 GRADING, STORM, AND PSE UPDATE ACCURACY OF THE INFORMATION PROVIDED >� D x /vli�hd t aedew n xyalota Lru dal BY THE CONTRACTORS AS -BUILT REDLINES. N0. REVISION CDX C M K 10/ 19/21 TJE suRvEYED: C M K 12 20 21 TJE DESIGNED: CMK CMK 02 18 22 TJE CB 0 6 17 2 2 TJE DRAWN: DC, JYL CB 12 20 23 TJE CHECKED: CB BY DATE AP P R APPROVED: TJE • Call 81 SIB two business days before you dig SCALE: IL NTAU NAD 1983/1991 AS SHOWN HOR ONE INCH DATU M AT FULL SCALE IF NOT ONE INCH SCALE ACCORDINGLY 10/14/2024 om- 1601 5th Avenue, Suite 1600 Seattle, WA 98101 206.622.5822 www.kpff.com ki CITY OF RENTON Planning/Building/Public Works Dept. 1. RESTORE UTILITY TRENCH TO EX GRADE IN ACCORDANCE WITH RMC 9-10-11 LO TRENCH RESTORATION AND STREET OVERLAY REQUIREMENTS. DOCUMENT EX T GRADE PRIOR TO CONSTRUCTION. o 2. FIELD VERIFY EXISTING 12" WATER MAIN STUB LOCATION PRIOR TO T INSTALLATION. REFER TO COR PROJECT WTR2703179 IN COR MAPS FOR I CV RECORD DRAWINGS. id 3. ALL WATER FITTINGS AND VALVES WITH MECHANICAL JOINT (MJ) END(S) SHALL HAVE A WEDGE —TYPE RETAINER GLAND EQUAL TO MEGALUG SERIES 1100. 4. CONCRETE THRUST BLOCKS ARE REQUIRED ON ALL WATER FITTINGS PER COR STD. PLANS 330.2 AND 330.3. 5. WHERE NEW WATER MAIN CROSSES A NON —POTABLE PIPE, ONE FULL LENGTH OF WATER PIPE SHALL BE USED WITH THE PIPE CENTERED FOR MAXIMUM JOINT SEPARATION. Q0 T 6. WATER MAIN PIPE DEFLECTION SHALL NOT EXCEED ONE HALF OF PIPE p MANUFACTURER'S SPECIFICATION FOR SIZE OF PIPE. O I N LEGEND Q J WATER < 12" N VALVE THRUST BLOCK r5_�� �31 SLEEVE O --——————————— — — — — —- SAWCUT T :.;.:_:.:. O ASPHALT PAVEMENT I N . . . . . . . . " 2" ASPHALT GRIND & OVERLAY R-419930 Y-A S-419903 0 10' 20' 40' � W-419903 1 inch = 20 feet z W IN COMPLIANCE WITH CITY OF RENTON STANDARDS p a w v) z D RENTON SUNSET GARDENS 10/14/2024 z FlELDBOOK: 2900 NE 10TH ST, RENTON, WA 98056 z O PAGE: DRAWING NO: C801 w WATER UTILITY PLAN SHE: 30 OF`44 Ir