Loading...
HomeMy WebLinkAboutT-4199060- co 0 6i N O N N 0 0 N N O N O N U 0 L I1 W I- L c� U W W x 0 Q 0 0 I- I CONSTRUCTION RECORD DRAWINGS THESE RECORD DOCUMENTS HAVE BEEN I Michael Ruether (THE I Dakota Simurdak (THE PREPARED FROM THE CONTRACTOR'S REDLINED CONTRACTOR OF RECORD) HEREBY CERTIFY SURVEYOR OF RECORD) HEREBY CERTIFY MARK-UPS OF THE CONSTRUCTION DOCUMENTS. THE CONSULTANT REVIEWING THAT THE FIELD MEASUREMENT INFORMATION THAT THE SURVEY INFORMATION SHOWN ON THESE RECORD DRAWINGS HAS NOT WITNESSED SHOWN ON THESE RECORD DRAWINGS THESE RECORD DRAWINGS ACCURATELY ALL THE ELEMENTS OF CONSTRUCTION AND IS ACCURATELY REFLECTS THE FIELD CONDITIONS REFLECTS THE FIELD CONDITIONS AS OF NOT RESPONSIBLE FOR ERRORS OR OMISSIONS AS OF 10/29/2024, 10/29/2024. IN DATA OR CERTIFY THE ACCURACY OF THE INFORMATION PROVIDED BY THE CONTRACTOR'S l fi��aeIleaedew oaeaea Lrawa'azC AS -BUILT REDLINES. X X ILLUMINATION POLE SCHEDULE LUM. POLE ID MOUNT. ARM BASE SERVICE/ POLE STREET NAME STATION OFFSET LATITUDE LONGITUDE WATTAGE VOLTAGE FIXTURE MODEL NO. NUMBER HEIGHT LENGTH TYPE CIRCUIT L1 5549A34 JEFFERSON AVE. 83+36.1 17.2' RT N470 29' 58.10736" E2370 49' 17.14572" 14' N/A 34W-LED 240 CITY OF RENTON STD. PLAN 116.1 FIXED A L2 5550A34 JEFFERSON AVE. 84+10.5 17.0' RT N470 29' 57.39428" E2370 49' 16.85857" 14' N/A 34W-LED 240 CITY OF RENTON STD. PLAN 116.1 FIXED A L3 10TH ST. NE EX EX 35' 8' 120W-LED EX GE EVOLVE ERL2 16C340 N/A N/A 5551 C60 (STREET) 10TH ST. NE 22+02.7 27.5' LT N470 29' 57.07401" E2370 49' 15.86318" 35' / 16.5' 8' / 4' 60W / 20W-LED 240 CITY OF RENTON STD. PLAN 117.1A FIXED A / B L4 55521320 (PED) L5 10TH ST. NE EX EX 35' 8' 38W-LED EX GE EVOLVE ERL1_04C340 N/A N/A 5553C60 (STREET) 10TH ST. NE 20+82.1 31.0' LT N470 29' 57.29039" E2370 49' 15.24708" 35' / 16.5' 8' / 4' 60W / 20W-LED 240 CITY OF RENTON STD. PLAN 117.1A FIXED A / B L6 55541320 (PED) L7 10TH ST. NE EX EX 35' 8' 120W-LED EX GE EVOLVE ERL2 16C340 N/A N/A L8 5555C60 (STREET) INDEX AVE. E 50+62.5 22.5' RT N470 29' 58.34597" E2370 49' 13.90017" 35' / 16.5' 8' / 4' 60W / 20W-LED 240 CITY OF RENTON STD. PLAN 117.1A FIXED A / B 55561320 (PED) 5557C60 (STREET) N470 29' 59.42061" E2370 49' 14.74599" L9 INDEX AVE. E 51+87.9 22.5' RT 35' / 16.5' 8' / 4' 60W / 20W-LED 240 CITY OF RENTON STD. PLAN 117.1A FIXED A / B 55581320 (PED) 5559C60 (STREET) N470 30' 00.39327" E2370 49' 15.64551" L10 INDEX AVE. E 53+05.2 22.5' RT 35' / 16.5' 8' / 4' 60W / 20W-LED 240 CITY OF RENTON STD. PLAN 117.1A FIXED A / B 5560B20 (PED) P1 5561 B20 10TH ST. NE 21+47.7 27.5' LT N470 29' 57.29039" E2370 49' 15.24708" 16.5' 4' 20W-LED 240 CITY OF RENTON STD. PLAN 117.2 FIXED B P2 55621320 INDEX AVE. E 51+28.7 22.5' RT N470 29' 58.91786" E2370 49' 14.33115" 16.5' 4' 20W-LED 240 CITY OF RENTON STD. PLAN 117.2 FIXED B P3 55631320 INDEX AVE. E 52+46.7 22.5' RT N470 29' 59.86240" E2370 49' 15.13981" 16.5' 4' 20W-LED 240 CITY OF RENTON STD. PLAN 117.2 FIXED B LIGHT LEVEL ANALYSIS* Location Classification Target Values Calculated Values Average Maintained Illuminance Uniformity Ave. Maintained Illuminance Calculated Uniformity 10th St NE Collector 0.9 Fc 4:1 1.2 Fc 1.6:1 10th St NE Sidewalk 0.3 Fc 6:1 1.6 Fc 2.2:1 Index Ave E Commercial Access 0.6 Fc 6:1 0.8 Fc 2.1:1 Index Ave E Sidewalk 0.3 Fc 6:1 1.4 Fc 2.4:1 Jefferson Ave Residential 0.8 Fc 6:1 1.0 Fc 3.3:1 Jefferson Ave Sidewalk 0.3 Fc 6:1 0.7 Fc 2.2:1 10th St / Index Ave Collector 1.2 Fc 4:1 1.4 Fc 2.0:1 10th St / Jefferson Ave Collector 1.2 Fc 4:1 1.3 Fc 1.9:1 * City of Renton Standards GENERAL NOTES 1. ALL WORK SHALL BE DONE IN ACCORDANCE WITH THE 2019 CITY OF RENTON STANDARDS AND SPECIFICATIONS. 2. THE LOCATION OF FEATURES SHOWN ARE APPROXIMATE AND SHALL BE VERIFIED BY THE CONTRACTOR PRIOR TO CONSTRUCTION START. 3. UTILITY LOCATIONS ARE APPROXIMATE AND SHALL BE VERIFIED IN THE FIELD BY THE CONTRACTOR PRIOR TO ANY ILLUMINATION WORK. 4. ALL WORK SHALL BE CONSISTENT WITH UTILITY AGENCY REQUIREMENTS. THE CONTRACTORS SHALL COORDINATE WITH AFFECTED UTILITY AGENCIES THROUGHOUT THE PROJECT. THE CONTRACTOR SHALL BE RESPONSIBLE FOR ANY DAMAGES TO UTILITIES. 5. TRENCHING SHALL BE ALLOWED WHERE NEW PAVEMENT IS BEING INSTALLED. 6. ALL CONDUIT SHALL BE INSTALLED WITH MINIMUM 24" COVER. 7. CONTRACTOR TO VERIFY SOIL CONDITIONS PRIOR TO CONSTRUCTION. 8. ELECTRICAL SERVICE TO BE COORDINATED WITH PSE. 9. CONTRACTOR SHALL CONTACT TRANSPORTATION MAINTENANCE MANAGER, ERIC CUTSHALL (425) 430-7423 FOR STREET LIGHTING INSPECTION PRIO TO ENERGIZING. SMR Architects 117 S. Main St., Suite 400 Seattle, WA 98104 PH: 206.623.1104 FX: 206.623.5285 RENTON, HODS I N G AUTHORITY RITY YEARS .o Transportation Solutions NN OVA T[VF. I PRAT iiCA I Ffj'.IliAklF 16932 Woodinville -Redmond Road, Suite A206 Woodinville, WA 98072 (425) 883-4134 1 www.tsinw.com Knowwhat's 10i10W. Call before you dig. SUNSET GARDENS 2900 NE 1OTH ST, RENTON, W/ 98056 CONSTRUCTION RECORD DRAWING REVISIONS / NOTES NO DATE DESCRIPTION Al 2/18/22 ADDENDA 1 o� WASH �L �• z z 25799 S �crSTER�4 �[ONAL E�` 11 /20/24 VLS STAMP TITLE ILLUMINATION Z!WAR 0 PERMIT # DRAWN MJS CHECKED JPKH ISSUE DATE 02.25.22 JOB NO. 220049 SHEET NO.: I L02