HomeMy WebLinkAboutPRE25-000049_Staff Comments_250320DEPARTMENT OF COMMUNITY
AND ECONOMIC DEVELOPMENT
Planning Division | 1055 South Grady Way, 6th Floor | Renton, WA 98057 | 425-430-7200 |www.rentonwa.gov
PREAPPLICATION MEETING FOR
Chriest Residence Addition
3605 Lake Washington Blvd N (APN 3342700330)
PRE 25-000049
03/20/2025
Contact Information:
Planner: Mariah Kerrihard, 425-430-7238, mkerrihard@rentonwa.gov
Public Works Plan Reviewer: Scott Warlick, 425-430-7216, swarlick@rentonwa.gov
Fire Prevention Reviewer: Corey Thomas, 425.276.9582, cthomas@RentonRFA.org
Building Department Reviewer: Rob Shuey, 206.550.8523, rshuey@rentonwa.gov
Please retain this packet throughout the course of your project as a reference. Consider
giving copies to engineers, architects, and contractors who will work on the project. You will
need to submit an PDF copy of this packet when you apply for land use and/or
environmental permits.
When the project application is ready for submittal, you may email the project planner to
start the prescreen process. Similarly, you may contact the assigned planner if there are any
questions regarding submittal requirements.
The pre-application meeting is informal and non-binding. The comments provided on the
proposal are based on the codes and policies in effect at the time of review. The applicant is
cautioned that the development regulations are regularly amended and the proposal will be
formally reviewed under the regulations in effect at the time of project submittal. The
information contained in this summary is subject to modification and/or concurrence by
official decision-makers (e.g., Hearing Examiner, Planning Director, Development Services
Director, Development Engineering Director, Department of Community & Economic
Development Administrator, Public Works Administrator and City Council).
DEPARTMENT OF COMMUNITY
AND ECONOMIC DEVELOPMENT
M E M O R A N D U M
DATE: March 17, 2025
TO: Mariah Kerrihard, Associate Planner
FROM: Scott Warlick, Development Engineering
SUBJECT: Chriest Residence Addition
3605 Lake Washington Blvd N
PRE25-000049
NOTE: The applicant is cautioned that information contained in this summary is preliminary and
non-binding and may be subject to modification and/or concurrence by official City decision-
makers. Review comments may also need to be revised based on site planning and other design
changes required by City staff or made by the applicant.
I have completed a preliminary review for the above-referenced proposal located at parcel(s)
3342700330. The following comments are based on the pre-application submittal made to the City
of Renton by the applicant.
WATER
1. The SFR is within the City of Renton’s water service area and in the Kennydale 308 Pressure
Zone.
2. There is an existing 8-inch water main in Mountain view Ave N (Record Dwg: W-274101).
The static water pressure is about 117 psi at ground elevation of 36-feet.
3. There is one existing hydrant located on Mountain View Ave N (Hydrant ID No. HYD-N-
00346) that appears to be within 300-feet of the SFR.
SEWER
1. Sewer service is provided by City of Renton.
2. There is an 8-inch force sewer main located in Lake Washington west of the property
(Record Dwg: S-015815).
3. There is an existing 6” PVC sewer stub serving the property.
4. This property is part of the Kennydale Lakeline Sewer Improvement Project. The City is
actively seeking a formal easement agreement from this property to allow the city to install,
operate, and maintain a grinder pump, power supply, and related pipes to provide sewer
service. Upon completion of the capital project, the existing sewer main located
underwater in Lake Washington will be decommissioned. Should the city not be granted an
easement for this work, the property owner will be responsible for connection to the new
PRE25-000049
Page 3 of 3
March 18, 2025
system, which may include purchase of a grinder pump, an electrical connection, regular
electricity service, pipes, labor to install the system, and all future maintenance. The costs
associated with a private connection can vary significantly, and the property owner is
encouraged to obtain quotes from qualified contractors. Once the existing sewer system
in the lake is decommissioned, if the connection to the new system has not been
established, the property will be without sewer service. Documentation regarding the
proposed easement has been provided to the property owner. For further information,
please contact City of Renton Project Manager, Anousheh Nawaz at 425-757-9156 or by e-
mail at ANawaz@RentonWA.gov.
SURFACE WATER
1. The site contains critical areas. There is a regulated shoreline, and a landslide hazard with
severity of moderate mapped on-site.
2. Drainage plans and a drainage report complying with the adopted 2022 Renton Surface
Water Design Manual will be required. Refer to Figure 1.1.2.A – Flow Chart of the 2022
Renton Surface Water Design Manual (RSWDM) to determine what type of drainage review
is required for this site. The site falls within the City’s Flow Control (matching existing peak
conditions) Standard. The site falls within the East Lake Washington drainage basin.
3. The current Surface Water Standard Plans shall be used in all drainage plan submittals.
The current City of Renton Standard Details are available online in the City of Renton
website
https://edocs.rentonwa.gov/Documents/Browse.aspx?id=990403&dbid=0&repo=CityofRenton
4. If the new plus replaced pollution generating impervious surface exceeds 5,000 SF, the
applicant will be required to provide basic water quality treatment. Any proposed detention
and/or water quality vault shall be designed in accordance with the RSWDM that is current
at the time of civil construction permit application. Separate structural plans will be
required to be submitted for review and approval under a separate building permit for the
detention and/or water quality vault.
5. Appropriate on-site BMPs satisfying Core Requirement #9 may be required to help mitigate
the new runoff created by this development to the maximum extent feasible. On-site BMPs
shall be evaluated in order of feasibility as described in Section C.1.3 of the 2022 RSWDM.
A preliminary drainage plan, including the application of on-site BMPs, shall be included
with the land use application, as applicable to the project. The final drainage plan and
drainage report must be submitted with the utility construction permit application.
6. A geotechnical soils report for the site may be required per the 2022 Renton Surface Water
Design Manual Section C.1.3. Information on the water table and soil permeability
(measured infiltration rates), with recommendations of appropriate on-site BMPs per Core
Requirement #9 and Appendix C shall be included in the report. The report should also
include information concerning the soils, geology, drainage patterns and vegetation
present shall be presented in order to evaluate the drainage, erosion control and slope
stability for site development of the proposed plat. The applicant must demonstrate the
development will not result in soil erosion and sedimentation, landslide, slippage, or
excess surface water runoff.
7. Erosion control measures to meet the City requirements shall be provided.
8. The development falls within the R-8 zone which has a maximum impervious surface area
of 65% per lot.
PRE25-000049
Page 3 of 3
March 18, 2025
9. The development is subject to a surface water system development charge (SDC) fee. Fees
will be charged based on the rate at the time of construction permit issuance.
a. The 2025 Surface water system development fee is $0.94 per sqft of new impervious
surface.
b. The full schedule can be found at:
https://edocs.rentonwa.gov/Documents/DocView.aspx?id=10593568&dbid=1&rep
o=CityofRenton.
TRANSPORTATION
1. Per City code 4-6-060 frontage improvements are required for new construction or addition in
excess of $175,000. The proposed project is not anticipated to trigger frontage improvements.
2. Undergrounding of all existing utilities is required on all frontages per RMC 4-6-090.
3. Refer to City code 4-4-080 regarding driveway regulations.
a. A minimum separation of 5-feet is required between driveway and the property line.
b. Maximum driveway slopes shall not exceed 15%. Driveways exceeding 8% shall provide
slotted drains.
c. The maximum width of single loaded garage driveway shall not exceed nine feet (9') and
double-loaded garage driveway shall not exceed sixteen feet (16').
4. Paving and trench restoration within the City of Renton right of way shall comply with the City’s
Trench Restoration and Street Overlay Requirements.
General Comments
1. If frontage improvements are required, all existing and proposed utility lines (i.e. electrical,
phone, and cable services, etc.) along property frontage or within the site must be
underground as outlined in RMC 4-6-090 – UTILITY LINES - UNDERGROUND INSTALLATION.
The construction of these franchise utilities must be inspected and approved by a City of
Renton inspector.
2. Maximum exposed retaining wall height is 6-ft and shall be setback a minimum of 3-ft from the
right-of-way as outlined in RMC 4-4-040 – Fences, Hedges and Retaining Walls.
3. Adequate separation between utilities as well as other features shall be provided in accordance
with code requirements.
a. 7-ft minimum horizontal and 1-ft vertical separation between storm and other utilities is
required with the exception of water lines which require 10-ft horizontal and 1.5-ft
vertical.
b. The stormwater line should be minimum 5 feet away from any other structure or wall or
building.
c. Trench of any utility should not be in the zone of influence of the retaining wall or of the
building.
4. All construction utility permits for utility and street improvements will require separate plan
submittals. All utility plans shall confirm to the Renton Drafting Standards. A licensed Civil
Engineer shall prepare the civil plans. Please visit the Development Engineering Forms page for
the most up-to-date plan submittal requirements:
https://rentonwa.gov/cms/one.aspx?portalId=7922741&pageId=9687014
5. A landscaping plan shall be included with the civil plan submittal. Each plan shall be on separate
sheets.
PRE25-000049
Page 3 of 3
March 18, 2025
6. Fees quoted in this document reflect the fees applicable in the year 2025 only and will be
assessed based on the fee that is current at the time of the permit application or issuance, as
applicable to the permit type. Please visit www.rentonwa.gov for the current development fee
schedule.
CityofRenton\Department Folders\Community and Economic Development (CED)\Current Planning\Pre-
Applications\2025\PRE25-000049
DEPARTMENT OF COMMUNITY
AND ECONOMIC DEVELOPMENT
M E M O R A N D U M
DATE: March 20, 2025
TO: Pre-Application File No. 25-000049
FROM: Mariah Kerrihard, Associate Planner
SUBJECT: Chriest Residence Addition
3605 Lake Washington Blvd N (APN 3342700330)
General: We have completed a preliminary review of the pre-application for the above-
referenced development proposal. The following comments on development and
permitting issues are based on the pre-application submittals made to the City of
Renton by the applicant and the codes in effect on the date of review. The applicant is
cautioned that information contained in this summary may be subject to modification and/or
concurrence by official decision-makers (e.g., Hearing Examiner, Community & Economic
Development Administrator, Public Works Administrator, Planning Director, Development
Services Director, Development Engineering Director, and City Council). Review comments
may also need to be revised based on site planning and other design changes required by
City staff or made by the applicant. The applicant is encouraged to review all applicable
sections of the Renton Municipal Code. The Development Regulations are available online
at https://www.codepublishing.com/WA/Renton.
Project Proposal: The subject property is located at 3605 Lake Washington Blvd N (APN
3342700330). The proposed project site is currently developed with an existing single-family
residence and is zoned Residential-6 (R-6). The applicant is proposing a second floor internal
remodel and an 82 square foot addition over the existing first floor deck, located
approximately 25 feet (25’) from the existing bulkhead. The project site is located along Lake
Washington and is subject to the requirements of the Shoreline Management Act and
Shoreline Master Program. Per Renton Municipal Code (RMC) 4-3-090, the vegetation
conservation buffer required for lots with a depth of between 100 feet and 130 feet is fifteen
feet (15’) with a fifteen-foot (15’) building setback from the edge of the buffer for a total
setback of thirty feet (30’). Architectural features of buildings, such as eaves or balconies,
and other building elements above the first floor may project a maximum of five feet (5') into
the building setback. These projections are allowed within the buffer when the building
setback is zero feet (0') from the buffer. According to City of Renton (COR) maps, the existing
single-family residence is located approximately twenty-five feet (25’) from the ordinary high-
water mark (OHWM) of Lake Washington, which would comply with shoreline setback
requirements. There are no changes in access proposed. The project site is located within
the Shoreline Residential Designation of Lake Washington, Reach D. According to COR
maps, moderate landslide hazards are mapped on the site.
Chriest Residence Addition
Page 2 of 5
March 19, 2025
CityofRenton\Department Folders\Community and Economic Development (CED)\Current Planning\Pre-
Applications\2025\PRE25-000049
Current Use: The site is currently developed with an existing single-family residence,
proposed to remain.
1. Zoning /Land Use Designation, and Overlays: The subject property is zoned
Residential-6 (R-6) zoning classification, and the Residential Medium Density (RMD)
Comprehensive Plan Land Use designation is intended to implement the (R-6) zone. The
Residential-6 Zone (R-6) is established for single family dwellings and is intended to
implement the Residential Medium Density Comprehensive Plan designation. The R-6
zone allows a range of three (3) to six (6) dwelling units per net acre. Development in the
R-6 zone is intended to be single family residential at moderate density. Detached
dwelling units are permitted within the R-6 zone and one (1) ADU is permitted per
legal lot1.
The density range allowed in the R-6 zone is a minimum of 3.0 to a maximum of 6.0
dwelling units per acre (du/ac). The area located within dedicated right-of-way would be
deducted from the gross site area to determine the “net” site area for calculating density.
The applicant would be required, at the time of formal land use application, to
provide net density calculations falling within the allowed range of the R-8 zoning
classification.
2. Development Standards: The project would be subject to RMC 4-2-110A,
“Development Standards for Single Family Zoning Designations” effective at the time of
complete application (noted as “R-6 standards” herein).
Minimum Lot Size, Width and Depth – The minimum lot size permitted in the R-6 zone,
according to the zoning standards, is 7,000 square feet for parcels being subdivided.
Minimum lot width is 60 feet for interior lots and 70 feet for corner lots; minimum lot
depth is 90 feet. For lots abutting a shoreline of the State, lot depth shall be measured
from and perpendicular to the OHWM to the opposing and most distant lot line or to an
easement containing existing physical improvements for road access for two (2) or more
lots. Detailed information is required at Preliminary Short Plat submittal to show
compliance with lot width, depth, and size requirements.
The submitted plans would need to show compliance with the required lot size and
dimensional standard with the land use application.
Building Standards – The Shoreline Residential Designation has a maximum building
coverage of twenty five percent (25%) for buildings landward of the vegetation
conservation buffer, and within 100 feet of the OHWM. In addition, the Shoreline
Residential Designation has a maximum impervious surface coverage of fifty percent
(50%) for the area landward of the vegetation conservation buffer and within 100 feet of
the OHWM. The maximum building height is restricted to 24 feet from the grade plane
to the highest wall plate and 2 stories. Roofs with a pitch equal to or greater than 4:12
may project an additional 6 vertical feet. The proposal appears to be above the maximum
24’ wall plate height. If the maximum allowed height in the underlying zoning is less than
the maximum allowed height in the shoreline overlay, a variance from the standards in
chapter 4-2 RMC, Zoning Districts – Uses and Standards, must be obtained from the
Administrator to allow any height over the amount allowed in the underlying zone. The
1 “Missing middle” house bills for housing (E2SHB 1110) and accessory dwelling units (EHB 1337).
Chriest Residence Addition
Page 3 of 5
March 19, 2025
CityofRenton\Department Folders\Community and Economic Development (CED)\Current Planning\Pre-
Applications\2025\PRE25-000049
proposed addition would be required to demonstrate compliance with these
requirements at the time of formal land use and building permit application.
Setbacks – Setbacks are the minimum required distance between the building footprint
and the property line and any private access easement. The required minimum setbacks
in the R-6 zone are 25 feet in the front, 25 feet in the rear and the side yard setback is 5
feet. Per RMC 4-3-090, the vegetation conservation buffer required for lots with a depth
of between 100 feet and 130 feet is fifteen feet (15’) with a fifteen-foot (15’) building
setback from the edge of the buffer for a total setback of thirty feet (30’). The existing
single-family residence is located approximately twenty-five feet (25’) from the
ordinary high-water mark (OHWM) of Lake Washington and is compliant with respect
to the shoreline setback requirements. The existing residence appears to project
into the required twenty-foot (20’) front yard setback. The applicant would be
required to demonstrate that the proposed additions would comply with the setback
requirements of the R-6 zone and the shoreline master program at the time of formal
land use and building permit application.
3. Significant Tree Retention: If significant trees (greater than 6-inch caliper or 8-caliper
inches for alders and cottonwoods) are proposed to be removed, a tree inventory and a
tree retention plan along with an arborist report, tree retention plan and tree retention
worksheet shall be provided with the formal land use application as defined in RMC 4-8-
120. The tree retention plan must show preservation of at least 30% of significant trees.
Please refer to RMC 4-4-130, Tree Retention and Land Clearing Regulations for further
general and specific tree retention and land clearing requirements.
In addition to retaining a minimum of 30% of existing significant trees, each new lot would
be required to provide a minimum tree density of 30 tree credits per net acre. Tree credits
encourage retention of existing significant trees with larger trees being worth more tree
credits.
TREE SIZE
TREE
CREDITS
New small species tree 0.25
New medium species tree 1
New large species tree 2
Preserved tree 6 – 9 caliper inches 4
Preserved tree 10 – 12 caliper inches 5
Preserved tree 12 – 15 caliper inches 6
Preserved tree 16 – 18 caliper inches 7
Preserved tree 19 – 21 caliper inches 8
Preserved tree 22 – 24 caliper inches 9
Chriest Residence Addition
Page 4 of 5
March 19, 2025
CityofRenton\Department Folders\Community and Economic Development (CED)\Current Planning\Pre-
Applications\2025\PRE25-000049
TREE SIZE
TREE
CREDITS
Preserved tree 25 – 28 caliper inches 10
Preserved tree 29 – 32 caliper inches 11
Preserved tree 33 – 36 caliper inches 12
Preserved tree 37 caliper inches and greater 13
Significant trees shall be retained in the following priority order:
Priority One: Landmark trees; significant trees that form a continuous canopy; significant
trees on slopes greater than twenty percent (20%); significant trees adjacent to critical
areas and their associated buffers; significant trees over sixty feet (60') in height or
greater than eighteen inches (18") caliper; and trees that shelter interior trees or trees on
abutting properties from strong winds, which could otherwise allow such sheltered trees
to be blown down if removed.
Priority Two: Healthy tree groupings whose associated undergrowth can be preserved;
other significant native evergreen or deciduous trees; and other significant non-native
trees.
Priority Three: Alders and cottonwoods shall be retained when all other trees have been
evaluated for retention and are not able to be retained, unless the alders and/or
cottonwoods are used as part of an approved enhancement project within a critical area
or its buffer.
The Administrator may require an independent review of any land use application that
involves tree removal and land clearing at the City's discretion.
The Administrator may authorize the planting of replacement trees on the site if it can be
demonstrated to the Administrator's satisfaction that replacement requirements in RMC
4-4-130H1e can be met.
Tree retention standards shall be applied to the developable area, as defined in RMC
4-11-040, Definitions D, of a property. A formal tree retention plan and tree retention
worksheet prepared by an arborist or landscape architect would be reviewed at the
time of the land use and building permit application.
4. Access/Parking: Each single family lot is required to accommodate off street parking for
a minimum of two (2) vehicles. Driveways and curb cuts are subject to RMC 4-4-080I. The
applicant would be required to demonstrate compliance with the parking
requirements at the time of formal land use and building permit application.
5. Critical Areas: According to the City’s COR Mapping system, the site is mapped within a
moderate landslide hazard area and is located within the 200-foot shoreline jurisdiction
of Lake Washington. The site is mapped within the Shoreline Residential Designation of
Lake Washington Reach D. Due to the presence of critical areas, a lake study may be
required at the time of building permit application. It is the applicant’s responsibility
Chriest Residence Addition
Page 5 of 5
March 19, 2025
CityofRenton\Department Folders\Community and Economic Development (CED)\Current Planning\Pre-
Applications\2025\PRE25-000049
to determine whether any other critical areas are present on the site prior to formal
land use application.
6. Shoreline Master Program: The project site is located within the Shoreline Residential
Designation of Lake Washington Reach D. Any proposed development of the project site
would be subject to the City’s adopted Shoreline Master Program (RMC 4-3-090). The
development of a single-family residence for the use and enjoyment of the property
owner would be exempt from a Shoreline Substantial Development Permit.
7. Environmental Review: The proposal would be exempt from Environmental (SEPA)
Review, in accordance with WAC 197-11-800.
8. Waivers of Submittal Requirements: The submittal checklist is not an exhaustive list of
submittal requirements and may be modified in cases where additional information is
required to complete the review of an application. In addition, non-applicable submittal
requirements may be waived. The applicant should contact the assigned Project
Manager if there are any questions regarding submittal requirements.
9. Permit Requirements: This project would require a Shoreline Exemption and a variance
application. The applications would be reviewed within an estimated time frame of eight
(8) weeks. Each variance request is $1,536. A 5% technology fee added to the total cost
of the reviews which would be assessed at the time of application. Shoreline Exemptions
are not subject to any application fees. All fees are subject to change. Detailed
information regarding the land use application submittal can be found on the City’s
Permit Center website (https://www.rentonwa.gov/City-Services/Permit-Center). Other
informational applications and handouts can be found on the City’s Digital Records
Library. The City requires electronic plan submittal for all applications. Please refer to
the City’s Electronic File Standards.
10. Next Steps: When the formal application materials are complete, the applicant shall
have the materials pre-screened prior to submitting the complete application package.
Please contact Mariah Kerrihard, Associate Planner, at 425-430-7238 or
mkerrihard@rentonwa.gov to submit prescreen materials and subsequent land use
application.
11. Expiration: The shoreline exemption is valid for two (2) years from the date of approval It
is the applicant’s responsibility to monitor the expiration dates.