Loading...
HomeMy WebLinkAboutMFP25001055.pdfDEPARTMENT OF COMMUNITY AND ECONOMIC DEVELOPMENT Major Franchise Permit: MFP25001055 IVR Number: 25001055 Permit Information Permit Name: JB0002058033 OSP DE WAKVD05500 Address/Location:03/03/2025Application Date:8944470000Parcel Number: 19167 110TH PL SE Permit Type:03/20/2025Issue Date:Franchise Permit Work Class:03/20/2026Expiration Date:Major Utility Job Number: JB0002058033Franchise Type:Cable Description: JB0002058033 Comcast proposes to overlash 48ct fiber to existing strand; replace existing equipment at aerial and UG locations; upgrade metal pedestals to doghouses; tie into existing splice case. Restoration per City of Renton standards. Contacts Name Address PhoneTypeBilling Gayle Berner Mastec North America Inc. H: (000) 000-0000 C: (253) 364-9363 Applicant Ashley Kiehn Mastec Communications 4610 Tacoma Avenue Sumner, WA 98390 ApplicantX Rena Watts Comcast 1575 75th St SW, #200 Everett, WA 98203 B: (425) 977-9120 C: (425) 977-9120 Contact Mastec North America Inc 800 S Douglas Road, 1200 Coral Gables, FL 33134 Contractor Business License Number: 51687Construction Contractor: MASTENA991KJ General Conditions & Signature Permission is hereby given for the work described on this permit according to the conditions hereon and according to the approved plans and specifications pertaining thereto, subject to compliance with the Ordinance of the City of Renton. Ÿ This permit and plans must be posted at the job site at all times.Ÿ I hereby certify that no work is to be done except as described above and in approved plans, and that work is to conform to Renton Trench Restoration and Street Overlay Requirements. Ÿ Call 425.430.7203 or go to: https://permitting.rentonwa.gov one working day in advance to schedule an inspections and for ANY work in the Right of Way. Ÿ Call 8 1 1 to locate underground utilities at least two full business days prior to any excavation.Ÿ In accordance with RCW 19.122.033(4) the permit holder is required to contact (Williams Northwest Pipeline at 425.868.1010) (Olympic Pipeline at 425.235.7736) (Puget Sound Energy at 425.375.3397) to request a consultation with the transmission pipeline company prior to performing any construction or excavation activities. This requirement to consult with the transmission pipeline company is in addition to the requirement to Call before You Dig as required in RCW 19.122. Ÿ (Date)(Signature) Page 1 of 1THIS PERMIT AND PLANS MUST BE POSTED AT THE JOB SITE AT ALL TIMES JB0002058033 OSP DE WAKVD05500 19167 110th PL SE, RENTON, WA 98055 4/3/2025 5/3/2025 8AM 330PM Mastec North America Gayle Berner 253-442-3574 4610 TACOMA AVE SUMNER, WA 98390 JB0002058033- Comcast proposes to overlash 48ct fiber to existing strand; replace existing equipment at aerial and UG locations, upgrade existing metal pedestals to doghouses; tie into existing splice case. MFP25001055 Monday Friday 3:00pm8:00am Scott Warlick CED 3/13/2025 Gayle Berner Gayle Berner 3/3/2025 FOCFOCFOCR/WR/WR/WR/W R/WR/WR/WR/W R/W R/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WFOCFOCFOCFOCR/W191741917511038110TH P L S E FOC FOC FOCFOCP 110TH PL SE19167 1916611014110TH PL SE110TH PL SESWSWSW SW SW SWSW REVISIONSDATEDESCRIPTIONINITIALTEMPORARY TRAFFICCONTROL PLANTRAFFIC CONTROL PLAN-128ADVANCED WARNING SIGN SPACINGROAD TYPESPEEDDISTANCE BETWEEN ADVANCEDWARNING SIGNSXXXXFREEWAYS & EXPRESSWAYS55/75 MPH1500 ±1500 ±1500 ±1500 ±RURAL HIGHWAYS60/65 MPH800 ±800 ±800 ±800 ±RURAL ROADS45/55 MPH500 ±500 ±500 ±500 ±RURAL ROADS & URBANARTERIAL35/40 MPH350 ±350 ±350 ±N/ARURAL ROADS, RESIDENTIAL &BUSINESS DISTRICTS25/30 MPH200 ± (2)200 ± (2)200 ± (2)N/AURBAN STREETS25 MPH ORLESS100 ± (2)100 ± (2)100 ± (2)N/A(1) ALL SPACING MAY BE ADJUSTED TO ACCOMMODATE INTERCHANGE RAMPS,AT-GRADE INTERSECTIONS, AND DRIVEWAYS.(2) THIS SPACING MAY BE REDUCED IN URBAN AREAS TO FIT ROADWAY CONDITIONS.LONGITUDINAL BUFFER SPACE =LBSSPEED (MPH)2025303540455055606570DISTANCE (FT)115155200250305360425495570645730TAPER LENGTH IN FEET=L (FEET)LANEWIDTH(FEET)POSTED SPEED LIMIT (MPH)2530354045505560657010105150205270450500550---11115160225295495550605660--121251802453205406006607207808401RDIGALERTFDX - WAKVD08600 1X2 - 19167 110TH PL SE RENTON, WA 98055, USA JB0002058033REVISIONSDATEDESCRIPTIONINITIAL COMCASTSHEETOFDATE:EXCEPT AS MAY BE OTHERWISE PROVIDED BY CONTRACT,THESE DRAWINGS AND SPECIFICATIONS SHALL REMAIN THEPROPERTY OF SEFNCO COMMUNICATION, INC. BOTH BEINGISSUED IN STRICT CONFIDENCE AND SHALL NOT BEREPRODUCED, COPIED, OR USED FOR ANY PURPOSEWITHOUT SPECIFIC WRITTEN PERMISSION.SITE NAME:SCALELOCATION ADDRESS: COMCAST JOB NUMBER: STAMPDRAWN BY:GAR02/13/2025WAKVD08500 1X2 (WAKVD05500 2X4)WARNING SIGNREGULATORY SIGNTRAFFIC CONEFLAGGER STATIONPATROL CARPOLICEOFFICERPOLICE OFFICERWORK VEHICLELIT INTERSECTIONUNLIT INTERSECTIONSPOTTER STATIONKEEPRIGHT TCP DEVICE LEGENDFASFLASHING ARROWFLASHING DOUBLE ARROW(MERGE LEFT OR RIGHT)FLASHING CAUTIONFASFASFASTRAFFIC CONTROL PLAN GENERAL NOTES1.AN ARROWBOARD SHALL MEET THE MINIMUM SIZE,LEGIBILITY DISTANCE, NUMBER OF ELEMENTS ANDOTHER SPECIFICATIONS SHOWN.2.LENGTH OF ARROW EQUALS 48", WIDTH OFARROWHEAD EQUALS 24".3.TYPE A, B AND C ARROW BOARDS SHALL HAVESOLID RECTANGULAR APPEARANCES. A TYPE DARROW BOARD SHALL CONFORM TO THE SHAPE OFTHE ARROW.4.MAINTAIN DRIVEWAY ACCESS AT ALL TIMES5.SIDEWALK ARE EITHER OPEN OR NOT OPEN. ASIDEWALK IS CLOSED IF A MINIMUM 5' PATH CANNOTBE MAINTAINED MEASURED FROM PROPERTY LINE,OR 5.5' IF CREATED FROM FACE OF CURB.(PEDESTRIAN PATH PROVIDED WHERE REQUIRED)AND WILL BE MONITORED BY A SPOTTER TOENSURE FLOW AND SAFETY DURING WORK UNLESSOTHERWISE NOTED. A SPOTTER SHALL NOT DIRECTTRAFFIC.6.NO EXCEPTION TAKEN- CONTRACTOR ISRESPONSIBLE FOR ADA COMPLIANCE.7.ALL CONTROL SET-UP, SIGN SPACING ANDPROCEDURES. WILL CONFORM TO SPECIFICATIONSSTATED IN THE FEDERAL MANUAL ON UNIFORMEDTRAFFIC CONTROL DEVICES (M.U.T.C.D).8.CITIES AND VARIOUS MUNICIPALITIES MAY HAVEALSO ADOPTED SPECIALIZED GUIDELINES FORTRAFFIC CONTROL WITHIN THEIR JURISDICTION. ITIS THE RESPONSIBILITY OF THE ON-SITE TRAFFICCONTROL PERSONAL TO SEE IF AND ANY SPECIALCONDITIONS EXIST.9.FLAGGERS SHALL BE USED IN ACCORDANCE WITHWAC 468-95-302.10.IF ONLY ONE LANE IS OPEN IN A DIRECTION,THATLANE SHALL BE A MINIMUM OF 11' WIDE, UNLESSSPOTTER/FLAGGERS ARE USED, IN WHICH CASETHE LANE CAN BE A MINIMUM OF 10'.11.ALL ROW WORK MUST YIELD TO SCHOOL TRANSIT,EMPLOYEES AND CHILDREN. WHILE PASSENGERLOADING/UNLOADING, STOPPED OR SLOWING:CEASE WORK, YIELD. WHEN SCHOOL TRANSIT,AND/OR PEDESTRIANS, DEPART COMMENCE WORK.NXXX ROADWORKAHEADONELANEROADAHEADFLAGGERSPOTTERSPOTTERLIMITSPEEDR2-12510' X X X ROADWORKAHEADONELANEROADAHEADFLAGGERLIMITSPEEDR2-125XXXROADWORKAHEAD ONELANEROADAHEAD FLAGGER LIMIT SPEED R2-1 25XXXROADWORKAHEADONELANEROADAHEADFLAGGERLIMITSPEEDR2-125MFP25001055 R/W R/WR/WR/W R/WR/WR/WR/W R/W R/WR/WR/WR/WR/WR/W R/WR/WR/WR/WR/WR/WFOC FOCFOCFOCFOC FOCFOCFOCP 110TH PL SE 110TH PL SE 191681912219167110TH PL SE110TH PL SESW SW SW110TH PL SE REVISIONSDATEDESCRIPTIONINITIALTEMPORARY TRAFFICCONTROL PLANTRAFFIC CONTROL PLAN-228ADVANCED WARNING SIGN SPACINGROAD TYPESPEEDDISTANCE BETWEEN ADVANCEDWARNING SIGNSXXXXFREEWAYS & EXPRESSWAYS55/75 MPH1500 ±1500 ±1500 ±1500 ±RURAL HIGHWAYS60/65 MPH800 ±800 ±800 ±800 ±RURAL ROADS45/55 MPH500 ±500 ±500 ±500 ±RURAL ROADS & URBANARTERIAL35/40 MPH350 ±350 ±350 ±N/ARURAL ROADS, RESIDENTIAL &BUSINESS DISTRICTS25/30 MPH200 ± (2)200 ± (2)200 ± (2)N/AURBAN STREETS25 MPH ORLESS100 ± (2)100 ± (2)100 ± (2)N/A(1) ALL SPACING MAY BE ADJUSTED TO ACCOMMODATE INTERCHANGE RAMPS,AT-GRADE INTERSECTIONS, AND DRIVEWAYS.(2) THIS SPACING MAY BE REDUCED IN URBAN AREAS TO FIT ROADWAY CONDITIONS.LONGITUDINAL BUFFER SPACE =LBSSPEED (MPH)2025303540455055606570DISTANCE (FT)115155200250305360425495570645730TAPER LENGTH IN FEET=L (FEET)LANEWIDTH(FEET)POSTED SPEED LIMIT (MPH)2530354045505560657010105150205270450500550---11115160225295495550605660--121251802453205406006607207808402RDIGALERTFDX - WAKVD08600 1X2 - 19167 110TH PL SE RENTON, WA 98055, USA JB0002058033REVISIONSDATEDESCRIPTIONINITIAL COMCASTSHEETOFDATE:EXCEPT AS MAY BE OTHERWISE PROVIDED BY CONTRACT,THESE DRAWINGS AND SPECIFICATIONS SHALL REMAIN THEPROPERTY OF SEFNCO COMMUNICATION, INC. BOTH BEINGISSUED IN STRICT CONFIDENCE AND SHALL NOT BEREPRODUCED, COPIED, OR USED FOR ANY PURPOSEWITHOUT SPECIFIC WRITTEN PERMISSION.SITE NAME:SCALELOCATION ADDRESS: COMCAST JOB NUMBER: STAMPDRAWN BY:GAR02/13/2025WAKVD08500 1X2 (WAKVD05500 2X4)WARNING SIGNREGULATORY SIGNTRAFFIC CONEFLAGGER STATIONPATROL CARPOLICEOFFICERPOLICE OFFICERWORK VEHICLELIT INTERSECTIONUNLIT INTERSECTIONSPOTTER STATIONKEEPRIGHT TCP DEVICE LEGENDFASFLASHING ARROWFLASHING DOUBLE ARROW(MERGE LEFT OR RIGHT)FLASHING CAUTIONFASFASFASTRAFFIC CONTROL PLAN GENERAL NOTES1.AN ARROWBOARD SHALL MEET THE MINIMUM SIZE,LEGIBILITY DISTANCE, NUMBER OF ELEMENTS ANDOTHER SPECIFICATIONS SHOWN.2.LENGTH OF ARROW EQUALS 48", WIDTH OFARROWHEAD EQUALS 24".3.TYPE A, B AND C ARROW BOARDS SHALL HAVESOLID RECTANGULAR APPEARANCES. A TYPE DARROW BOARD SHALL CONFORM TO THE SHAPE OFTHE ARROW.4.MAINTAIN DRIVEWAY ACCESS AT ALL TIMES5.SIDEWALK ARE EITHER OPEN OR NOT OPEN. ASIDEWALK IS CLOSED IF A MINIMUM 5' PATH CANNOTBE MAINTAINED MEASURED FROM PROPERTY LINE,OR 5.5' IF CREATED FROM FACE OF CURB.(PEDESTRIAN PATH PROVIDED WHERE REQUIRED)AND WILL BE MONITORED BY A SPOTTER TOENSURE FLOW AND SAFETY DURING WORK UNLESSOTHERWISE NOTED. A SPOTTER SHALL NOT DIRECTTRAFFIC.6.NO EXCEPTION TAKEN- CONTRACTOR ISRESPONSIBLE FOR ADA COMPLIANCE.7.ALL CONTROL SET-UP, SIGN SPACING ANDPROCEDURES. WILL CONFORM TO SPECIFICATIONSSTATED IN THE FEDERAL MANUAL ON UNIFORMEDTRAFFIC CONTROL DEVICES (M.U.T.C.D).8.CITIES AND VARIOUS MUNICIPALITIES MAY HAVEALSO ADOPTED SPECIALIZED GUIDELINES FORTRAFFIC CONTROL WITHIN THEIR JURISDICTION. ITIS THE RESPONSIBILITY OF THE ON-SITE TRAFFICCONTROL PERSONAL TO SEE IF AND ANY SPECIALCONDITIONS EXIST.9.FLAGGERS SHALL BE USED IN ACCORDANCE WITHWAC 468-95-302.10.IF ONLY ONE LANE IS OPEN IN A DIRECTION,THATLANE SHALL BE A MINIMUM OF 11' WIDE, UNLESSSPOTTER/FLAGGERS ARE USED, IN WHICH CASETHE LANE CAN BE A MINIMUM OF 10'.11.ALL ROW WORK MUST YIELD TO SCHOOL TRANSIT,EMPLOYEES AND CHILDREN. WHILE PASSENGERLOADING/UNLOADING, STOPPED OR SLOWING:CEASE WORK, YIELD. WHEN SCHOOL TRANSIT,AND/OR PEDESTRIANS, DEPART COMMENCE WORK.NTOW-AWAY AREA RCW 46 55 113NOTE:ADJACENT BUSINESSES AND/OR RESIDENT'SWILL BE NOTIFIED IN WRITING 72 HOURS PRIORTO PLACEMENT OF "NO PARKING" SIGNS.MFP25001055 R/WR/WEOP EOP EOP EOP EOP EOP R/W R/W R/W R/W R/W 19032190401903719015106TH AVE SE 106TH AVE SE R/W R/W R/W R/W R/W R/W R/W R/W POLE RDIGALERTFDX - WAKVD08600 1X2 - 19167 110TH PL SE RENTON, WA 98055, USA JB0002058033REVISIONSDATEDESCRIPTIONINITIAL COMCASTSHEETOFDATE:EXCEPT AS MAY BE OTHERWISE PROVIDED BY CONTRACT,THESE DRAWINGS AND SPECIFICATIONS SHALL REMAIN THEPROPERTY OF SEFNCO COMMUNICATION, INC. BOTH BEINGISSUED IN STRICT CONFIDENCE AND SHALL NOT BEREPRODUCED, COPIED, OR USED FOR ANY PURPOSEWITHOUT SPECIFIC WRITTEN PERMISSION.SITE NAME:SCALELOCATION ADDRESS: COMCAST JOB NUMBER: STAMPDRAWN BY:GAR02/13/2025WAKVD08500 1X2 (WAKVD05500 2X4)REVISIONSDATEDESCRIPTIONINITIALTEMPORARY TRAFFICCONTROL PLANTRAFFIC CONTROL PLAN-328ADVANCED WARNING SIGN SPACINGROAD TYPESPEEDDISTANCE BETWEEN ADVANCEDWARNING SIGNSXXXXFREEWAYS & EXPRESSWAYS55/75 MPH1500 ±1500 ±1500 ±1500 ±RURAL HIGHWAYS60/65 MPH800 ±800 ±800 ±800 ±RURAL ROADS45/55 MPH500 ±500 ±500 ±500 ±RURAL ROADS & URBANARTERIAL35/40 MPH350 ±350 ±350 ±N/ARURAL ROADS, RESIDENTIAL &BUSINESS DISTRICTS25/30 MPH200 ± (2)200 ± (2)200 ± (2)N/AURBAN STREETS25 MPH ORLESS100 ± (2)100 ± (2)100 ± (2)N/A(1) ALL SPACING MAY BE ADJUSTED TO ACCOMMODATE INTERCHANGE RAMPS,AT-GRADE INTERSECTIONS, AND DRIVEWAYS.(2) THIS SPACING MAY BE REDUCED IN URBAN AREAS TO FIT ROADWAY CONDITIONS.LONGITUDINAL BUFFER SPACE =LBSSPEED (MPH)2025303540455055606570DISTANCE (FT)115155200250305360425495570645730TAPER LENGTH IN FEET=L (FEET)LANEWIDTH(FEET)POSTED SPEED LIMIT (MPH)2530354045505560657010105150205270450500550---11115160225295495550605660--121251802453205406006607207808403WARNING SIGNREGULATORY SIGNTRAFFIC CONEFLAGGER STATIONPATROL CARPOLICEOFFICERPOLICE OFFICERWORK VEHICLELIT INTERSECTIONUNLIT INTERSECTIONSPOTTER STATIONKEEPRIGHT TCP DEVICE LEGENDFASFLASHING ARROWFLASHING DOUBLE ARROW(MERGE LEFT OR RIGHT)FLASHING CAUTIONFASFASFASTRAFFIC CONTROL PLAN GENERAL NOTES1.AN ARROWBOARD SHALL MEET THE MINIMUM SIZE,LEGIBILITY DISTANCE, NUMBER OF ELEMENTS ANDOTHER SPECIFICATIONS SHOWN.2.LENGTH OF ARROW EQUALS 48", WIDTH OFARROWHEAD EQUALS 24".3.TYPE A, B AND C ARROW BOARDS SHALL HAVESOLID RECTANGULAR APPEARANCES. A TYPE DARROW BOARD SHALL CONFORM TO THE SHAPE OFTHE ARROW.4.MAINTAIN DRIVEWAY ACCESS AT ALL TIMES5.SIDEWALK ARE EITHER OPEN OR NOT OPEN. ASIDEWALK IS CLOSED IF A MINIMUM 5' PATH CANNOTBE MAINTAINED MEASURED FROM PROPERTY LINE,OR 5.5' IF CREATED FROM FACE OF CURB.(PEDESTRIAN PATH PROVIDED WHERE REQUIRED)AND WILL BE MONITORED BY A SPOTTER TOENSURE FLOW AND SAFETY DURING WORK UNLESSOTHERWISE NOTED. A SPOTTER SHALL NOT DIRECTTRAFFIC.6.NO EXCEPTION TAKEN- CONTRACTOR ISRESPONSIBLE FOR ADA COMPLIANCE.7.ALL CONTROL SET-UP, SIGN SPACING ANDPROCEDURES. WILL CONFORM TO SPECIFICATIONSSTATED IN THE FEDERAL MANUAL ON UNIFORMEDTRAFFIC CONTROL DEVICES (M.U.T.C.D).8.CITIES AND VARIOUS MUNICIPALITIES MAY HAVEALSO ADOPTED SPECIALIZED GUIDELINES FORTRAFFIC CONTROL WITHIN THEIR JURISDICTION. ITIS THE RESPONSIBILITY OF THE ON-SITE TRAFFICCONTROL PERSONAL TO SEE IF AND ANY SPECIALCONDITIONS EXIST.9.FLAGGERS SHALL BE USED IN ACCORDANCE WITHWAC 468-95-302.10.IF ONLY ONE LANE IS OPEN IN A DIRECTION,THATLANE SHALL BE A MINIMUM OF 11' WIDE, UNLESSSPOTTER/FLAGGERS ARE USED, IN WHICH CASETHE LANE CAN BE A MINIMUM OF 10'.11.ALL ROW WORK MUST YIELD TO SCHOOL TRANSIT,EMPLOYEES AND CHILDREN. WHILE PASSENGERLOADING/UNLOADING, STOPPED OR SLOWING:CEASE WORK, YIELD. WHEN SCHOOL TRANSIT,AND/OR PEDESTRIANS, DEPART COMMENCE WORK.NXXX ROADWORKAHEADSHOULDERWORKRIGHTSHOULDERCLOSEDX ROADWORKAHEADSPOTTERLIMITSPEEDR2-125LIMITSPEEDR2-125MFP25001055 R/W R/W R/W R/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/W R/W R/WR/WR/WR/WR/WR/WFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLEOP EOP EOP FLFLFLFLFLFLFLEOP EOPFLFLFLFLFLFLFLEOPEOPR/WR/WEOPEOPEOPEOP19207106071906019059SE 192ND STSE 192ND ST106TH AVE SE 106TH AVE SE R/W R/W R/WPOLE RDIGALERTFDX - WAKVD08600 1X2 - 19167 110TH PL SE RENTON, WA 98055, USA JB0002058033REVISIONSDATEDESCRIPTIONINITIAL COMCASTSHEETOFDATE:EXCEPT AS MAY BE OTHERWISE PROVIDED BY CONTRACT,THESE DRAWINGS AND SPECIFICATIONS SHALL REMAIN THEPROPERTY OF SEFNCO COMMUNICATION, INC. BOTH BEINGISSUED IN STRICT CONFIDENCE AND SHALL NOT BEREPRODUCED, COPIED, OR USED FOR ANY PURPOSEWITHOUT SPECIFIC WRITTEN PERMISSION.SITE NAME:SCALELOCATION ADDRESS: COMCAST JOB NUMBER: STAMPDRAWN BY:GAR02/13/2025WAKVD08500 1X2 (WAKVD05500 2X4)REVISIONSDATEDESCRIPTIONINITIALTEMPORARY TRAFFICCONTROL PLANTRAFFIC CONTROL PLAN-428ADVANCED WARNING SIGN SPACINGROAD TYPESPEEDDISTANCE BETWEEN ADVANCEDWARNING SIGNSXXXXFREEWAYS & EXPRESSWAYS55/75 MPH1500 ±1500 ±1500 ±1500 ±RURAL HIGHWAYS60/65 MPH800 ±800 ±800 ±800 ±RURAL ROADS45/55 MPH500 ±500 ±500 ±500 ±RURAL ROADS & URBANARTERIAL35/40 MPH350 ±350 ±350 ±N/ARURAL ROADS, RESIDENTIAL &BUSINESS DISTRICTS25/30 MPH200 ± (2)200 ± (2)200 ± (2)N/AURBAN STREETS25 MPH ORLESS100 ± (2)100 ± (2)100 ± (2)N/A(1) ALL SPACING MAY BE ADJUSTED TO ACCOMMODATE INTERCHANGE RAMPS,AT-GRADE INTERSECTIONS, AND DRIVEWAYS.(2) THIS SPACING MAY BE REDUCED IN URBAN AREAS TO FIT ROADWAY CONDITIONS.LONGITUDINAL BUFFER SPACE =LBSSPEED (MPH)2025303540455055606570DISTANCE (FT)115155200250305360425495570645730TAPER LENGTH IN FEET=L (FEET)LANEWIDTH(FEET)POSTED SPEED LIMIT (MPH)2530354045505560657010105150205270450500550---11115160225295495550605660--121251802453205406006607207808404WARNING SIGNREGULATORY SIGNTRAFFIC CONEFLAGGER STATIONPATROL CARPOLICEOFFICERPOLICE OFFICERWORK VEHICLELIT INTERSECTIONUNLIT INTERSECTIONSPOTTER STATIONKEEPRIGHT TCP DEVICE LEGENDFASFLASHING ARROWFLASHING DOUBLE ARROW(MERGE LEFT OR RIGHT)FLASHING CAUTIONFASFASFASTRAFFIC CONTROL PLAN GENERAL NOTES1.AN ARROWBOARD SHALL MEET THE MINIMUM SIZE,LEGIBILITY DISTANCE, NUMBER OF ELEMENTS ANDOTHER SPECIFICATIONS SHOWN.2.LENGTH OF ARROW EQUALS 48", WIDTH OFARROWHEAD EQUALS 24".3.TYPE A, B AND C ARROW BOARDS SHALL HAVESOLID RECTANGULAR APPEARANCES. A TYPE DARROW BOARD SHALL CONFORM TO THE SHAPE OFTHE ARROW.4.MAINTAIN DRIVEWAY ACCESS AT ALL TIMES5.SIDEWALK ARE EITHER OPEN OR NOT OPEN. ASIDEWALK IS CLOSED IF A MINIMUM 5' PATH CANNOTBE MAINTAINED MEASURED FROM PROPERTY LINE,OR 5.5' IF CREATED FROM FACE OF CURB.(PEDESTRIAN PATH PROVIDED WHERE REQUIRED)AND WILL BE MONITORED BY A SPOTTER TOENSURE FLOW AND SAFETY DURING WORK UNLESSOTHERWISE NOTED. A SPOTTER SHALL NOT DIRECTTRAFFIC.6.NO EXCEPTION TAKEN- CONTRACTOR ISRESPONSIBLE FOR ADA COMPLIANCE.7.ALL CONTROL SET-UP, SIGN SPACING ANDPROCEDURES. WILL CONFORM TO SPECIFICATIONSSTATED IN THE FEDERAL MANUAL ON UNIFORMEDTRAFFIC CONTROL DEVICES (M.U.T.C.D).8.CITIES AND VARIOUS MUNICIPALITIES MAY HAVEALSO ADOPTED SPECIALIZED GUIDELINES FORTRAFFIC CONTROL WITHIN THEIR JURISDICTION. ITIS THE RESPONSIBILITY OF THE ON-SITE TRAFFICCONTROL PERSONAL TO SEE IF AND ANY SPECIALCONDITIONS EXIST.9.FLAGGERS SHALL BE USED IN ACCORDANCE WITHWAC 468-95-302.10.IF ONLY ONE LANE IS OPEN IN A DIRECTION,THATLANE SHALL BE A MINIMUM OF 11' WIDE, UNLESSSPOTTER/FLAGGERS ARE USED, IN WHICH CASETHE LANE CAN BE A MINIMUM OF 10'.11.ALL ROW WORK MUST YIELD TO SCHOOL TRANSIT,EMPLOYEES AND CHILDREN. WHILE PASSENGERLOADING/UNLOADING, STOPPED OR SLOWING:CEASE WORK, YIELD. WHEN SCHOOL TRANSIT,AND/OR PEDESTRIANS, DEPART COMMENCE WORK.NX X X ROADWORKAHEADONELANEROADAHEADLIMITSPEEDR2-125FLAGGERXXX ROADWORKAHEADONELANEROADAHEADLIMITSPEEDR2-125FLAGGERXXXROADWORKAHEAD ONELANEROADAHEAD LIMIT SPEED R2-1 25 FLAGGERXXXROADWORKAHEADONELANEROADAHEADLIMITSPEEDR2-125FLAGGERSPOTTERMFP25001055 R/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLR/WR/WR/WR/WR/W R/WR/WFLFLFLR/WR/WR/WR/WR/WFOCFOCFOCFOCEOPEOPEOPFOCFOC FOCFOC 1042110424104201912910326SE 192ND STSE 192ND ST104TH PL SE EOPEOPEOPSWSWSWSWSWSWSWSWSW SWSW POLEPOLERDIGALERTFDX - WAKVD08600 1X2 - 19167 110TH PL SE RENTON, WA 98055, USA JB0002058033REVISIONSDATEDESCRIPTIONINITIAL COMCASTSHEETOFDATE:EXCEPT AS MAY BE OTHERWISE PROVIDED BY CONTRACT,THESE DRAWINGS AND SPECIFICATIONS SHALL REMAIN THEPROPERTY OF SEFNCO COMMUNICATION, INC. BOTH BEINGISSUED IN STRICT CONFIDENCE AND SHALL NOT BEREPRODUCED, COPIED, OR USED FOR ANY PURPOSEWITHOUT SPECIFIC WRITTEN PERMISSION.SITE NAME:SCALELOCATION ADDRESS: COMCAST JOB NUMBER: STAMPDRAWN BY:GAR02/13/2025WAKVD08500 1X2 (WAKVD05500 2X4)REVISIONSDATEDESCRIPTIONINITIALTEMPORARY TRAFFICCONTROL PLANTRAFFIC CONTROL PLAN-528ADVANCED WARNING SIGN SPACINGROAD TYPESPEEDDISTANCE BETWEEN ADVANCEDWARNING SIGNSXXXXFREEWAYS & EXPRESSWAYS55/75 MPH1500 ±1500 ±1500 ±1500 ±RURAL HIGHWAYS60/65 MPH800 ±800 ±800 ±800 ±RURAL ROADS45/55 MPH500 ±500 ±500 ±500 ±RURAL ROADS & URBANARTERIAL35/40 MPH350 ±350 ±350 ±N/ARURAL ROADS, RESIDENTIAL &BUSINESS DISTRICTS25/30 MPH200 ± (2)200 ± (2)200 ± (2)N/AURBAN STREETS25 MPH ORLESS100 ± (2)100 ± (2)100 ± (2)N/A(1) ALL SPACING MAY BE ADJUSTED TO ACCOMMODATE INTERCHANGE RAMPS,AT-GRADE INTERSECTIONS, AND DRIVEWAYS.(2) THIS SPACING MAY BE REDUCED IN URBAN AREAS TO FIT ROADWAY CONDITIONS.LONGITUDINAL BUFFER SPACE =LBSSPEED (MPH)2025303540455055606570DISTANCE (FT)115155200250305360425495570645730TAPER LENGTH IN FEET=L (FEET)LANEWIDTH(FEET)POSTED SPEED LIMIT (MPH)2530354045505560657010105150205270450500550---11115160225295495550605660--121251802453205406006607207808405WARNING SIGNREGULATORY SIGNTRAFFIC CONEFLAGGER STATIONPATROL CARPOLICEOFFICERPOLICE OFFICERWORK VEHICLELIT INTERSECTIONUNLIT INTERSECTIONSPOTTER STATIONKEEPRIGHT TCP DEVICE LEGENDFASFLASHING ARROWFLASHING DOUBLE ARROW(MERGE LEFT OR RIGHT)FLASHING CAUTIONFASFASFASTRAFFIC CONTROL PLAN GENERAL NOTES1.AN ARROWBOARD SHALL MEET THE MINIMUM SIZE,LEGIBILITY DISTANCE, NUMBER OF ELEMENTS ANDOTHER SPECIFICATIONS SHOWN.2.LENGTH OF ARROW EQUALS 48", WIDTH OFARROWHEAD EQUALS 24".3.TYPE A, B AND C ARROW BOARDS SHALL HAVESOLID RECTANGULAR APPEARANCES. A TYPE DARROW BOARD SHALL CONFORM TO THE SHAPE OFTHE ARROW.4.MAINTAIN DRIVEWAY ACCESS AT ALL TIMES5.SIDEWALK ARE EITHER OPEN OR NOT OPEN. ASIDEWALK IS CLOSED IF A MINIMUM 5' PATH CANNOTBE MAINTAINED MEASURED FROM PROPERTY LINE,OR 5.5' IF CREATED FROM FACE OF CURB.(PEDESTRIAN PATH PROVIDED WHERE REQUIRED)AND WILL BE MONITORED BY A SPOTTER TOENSURE FLOW AND SAFETY DURING WORK UNLESSOTHERWISE NOTED. A SPOTTER SHALL NOT DIRECTTRAFFIC.6.NO EXCEPTION TAKEN- CONTRACTOR ISRESPONSIBLE FOR ADA COMPLIANCE.7.ALL CONTROL SET-UP, SIGN SPACING ANDPROCEDURES. WILL CONFORM TO SPECIFICATIONSSTATED IN THE FEDERAL MANUAL ON UNIFORMEDTRAFFIC CONTROL DEVICES (M.U.T.C.D).8.CITIES AND VARIOUS MUNICIPALITIES MAY HAVEALSO ADOPTED SPECIALIZED GUIDELINES FORTRAFFIC CONTROL WITHIN THEIR JURISDICTION. ITIS THE RESPONSIBILITY OF THE ON-SITE TRAFFICCONTROL PERSONAL TO SEE IF AND ANY SPECIALCONDITIONS EXIST.9.FLAGGERS SHALL BE USED IN ACCORDANCE WITHWAC 468-95-302.10.IF ONLY ONE LANE IS OPEN IN A DIRECTION,THATLANE SHALL BE A MINIMUM OF 11' WIDE, UNLESSSPOTTER/FLAGGERS ARE USED, IN WHICH CASETHE LANE CAN BE A MINIMUM OF 10'.11.ALL ROW WORK MUST YIELD TO SCHOOL TRANSIT,EMPLOYEES AND CHILDREN. WHILE PASSENGERLOADING/UNLOADING, STOPPED OR SLOWING:CEASE WORK, YIELD. WHEN SCHOOL TRANSIT,AND/OR PEDESTRIANS, DEPART COMMENCE WORK.NXXX ROADWORKAHEADONELANEROADAHEADLIMITSPEEDR2-125FLAGGERXXXROADWORKAHEAD ONELANEROADAHEAD LIMIT SPEED R2-1 25 FLAGGERXXXROADWORKAHEADONELANEROADAHEADLIMITSPEEDR2-125FLAGGERSPOTTERMFP25001055 R/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFOCR/WR/WR/WR/WR/WR/WR/WR/W R/WR/WR/WR/WR/WR/WFOCFOCFOCFOCEOPFOCFOC FOCFOC 104211042410420191291032610321SE 192ND STSE 192ND ST104TH PL SEEOPEOP EOPEOPEOPSWSWSWSWSWSWSWSWSWSWSWSW POLEPOLERDIGALERTFDX - WAKVD08600 1X2 - 19167 110TH PL SE RENTON, WA 98055, USA JB0002058033REVISIONSDATEDESCRIPTIONINITIAL COMCASTSHEETOFDATE:EXCEPT AS MAY BE OTHERWISE PROVIDED BY CONTRACT,THESE DRAWINGS AND SPECIFICATIONS SHALL REMAIN THEPROPERTY OF SEFNCO COMMUNICATION, INC. BOTH BEINGISSUED IN STRICT CONFIDENCE AND SHALL NOT BEREPRODUCED, COPIED, OR USED FOR ANY PURPOSEWITHOUT SPECIFIC WRITTEN PERMISSION.SITE NAME:SCALELOCATION ADDRESS: COMCAST JOB NUMBER: STAMPDRAWN BY:GAR02/13/2025WAKVD08500 1X2 (WAKVD05500 2X4)REVISIONSDATEDESCRIPTIONINITIALTEMPORARY TRAFFICCONTROL PLANTRAFFIC CONTROL PLAN-628ADVANCED WARNING SIGN SPACINGROAD TYPESPEEDDISTANCE BETWEEN ADVANCEDWARNING SIGNSXXXXFREEWAYS & EXPRESSWAYS55/75 MPH1500 ±1500 ±1500 ±1500 ±RURAL HIGHWAYS60/65 MPH800 ±800 ±800 ±800 ±RURAL ROADS45/55 MPH500 ±500 ±500 ±500 ±RURAL ROADS & URBANARTERIAL35/40 MPH350 ±350 ±350 ±N/ARURAL ROADS, RESIDENTIAL &BUSINESS DISTRICTS25/30 MPH200 ± (2)200 ± (2)200 ± (2)N/AURBAN STREETS25 MPH ORLESS100 ± (2)100 ± (2)100 ± (2)N/A(1) ALL SPACING MAY BE ADJUSTED TO ACCOMMODATE INTERCHANGE RAMPS,AT-GRADE INTERSECTIONS, AND DRIVEWAYS.(2) THIS SPACING MAY BE REDUCED IN URBAN AREAS TO FIT ROADWAY CONDITIONS.LONGITUDINAL BUFFER SPACE =LBSSPEED (MPH)2025303540455055606570DISTANCE (FT)115155200250305360425495570645730TAPER LENGTH IN FEET=L (FEET)LANEWIDTH(FEET)POSTED SPEED LIMIT (MPH)2530354045505560657010105150205270450500550---11115160225295495550605660--121251802453205406006607207808406WARNING SIGNREGULATORY SIGNTRAFFIC CONEFLAGGER STATIONPATROL CARPOLICEOFFICERPOLICE OFFICERWORK VEHICLELIT INTERSECTIONUNLIT INTERSECTIONSPOTTER STATIONKEEPRIGHT TCP DEVICE LEGENDFASFLASHING ARROWFLASHING DOUBLE ARROW(MERGE LEFT OR RIGHT)FLASHING CAUTIONFASFASFASTRAFFIC CONTROL PLAN GENERAL NOTES1.AN ARROWBOARD SHALL MEET THE MINIMUM SIZE,LEGIBILITY DISTANCE, NUMBER OF ELEMENTS ANDOTHER SPECIFICATIONS SHOWN.2.LENGTH OF ARROW EQUALS 48", WIDTH OFARROWHEAD EQUALS 24".3.TYPE A, B AND C ARROW BOARDS SHALL HAVESOLID RECTANGULAR APPEARANCES. A TYPE DARROW BOARD SHALL CONFORM TO THE SHAPE OFTHE ARROW.4.MAINTAIN DRIVEWAY ACCESS AT ALL TIMES5.SIDEWALK ARE EITHER OPEN OR NOT OPEN. ASIDEWALK IS CLOSED IF A MINIMUM 5' PATH CANNOTBE MAINTAINED MEASURED FROM PROPERTY LINE,OR 5.5' IF CREATED FROM FACE OF CURB.(PEDESTRIAN PATH PROVIDED WHERE REQUIRED)AND WILL BE MONITORED BY A SPOTTER TOENSURE FLOW AND SAFETY DURING WORK UNLESSOTHERWISE NOTED. A SPOTTER SHALL NOT DIRECTTRAFFIC.6.NO EXCEPTION TAKEN- CONTRACTOR ISRESPONSIBLE FOR ADA COMPLIANCE.7.ALL CONTROL SET-UP, SIGN SPACING ANDPROCEDURES. WILL CONFORM TO SPECIFICATIONSSTATED IN THE FEDERAL MANUAL ON UNIFORMEDTRAFFIC CONTROL DEVICES (M.U.T.C.D).8.CITIES AND VARIOUS MUNICIPALITIES MAY HAVEALSO ADOPTED SPECIALIZED GUIDELINES FORTRAFFIC CONTROL WITHIN THEIR JURISDICTION. ITIS THE RESPONSIBILITY OF THE ON-SITE TRAFFICCONTROL PERSONAL TO SEE IF AND ANY SPECIALCONDITIONS EXIST.9.FLAGGERS SHALL BE USED IN ACCORDANCE WITHWAC 468-95-302.10.IF ONLY ONE LANE IS OPEN IN A DIRECTION,THATLANE SHALL BE A MINIMUM OF 11' WIDE, UNLESSSPOTTER/FLAGGERS ARE USED, IN WHICH CASETHE LANE CAN BE A MINIMUM OF 10'.11.ALL ROW WORK MUST YIELD TO SCHOOL TRANSIT,EMPLOYEES AND CHILDREN. WHILE PASSENGERLOADING/UNLOADING, STOPPED OR SLOWING:CEASE WORK, YIELD. WHEN SCHOOL TRANSIT,AND/OR PEDESTRIANS, DEPART COMMENCE WORK.NXXX ROADWORKAHEADONELANEROADAHEADLIMITSPEEDR2-125FLAGGERXXXROADWORKAHEADONELANEROADAHEADLIMITSPEEDR2-125FLAGGERXXXROADWORKAHEAD ONELANEROADAHEAD LIMIT SPEED R2-1 25 FLAGGERSPOTTER MFP25001055 R/W R/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WFLFLFLFLFLFLEOP FOCFOCR/WR/WR/WR/WR/WR/WR/WR/WR/WFOCFOCFOCFOCFOC FOCFOCFLFLFLFLFLFLFLFLFLFLFLR/WR/WR/WR/WR/WR/WR/WFOC FOC FOCFOCFOC FOC1011219213 19202192081904510204SE 192ND STSE 192ND ST102ND AVE SE 101ST PL SE(PRIVATE RD) 102ND AVE SE EOPEOPEOPEOPEOP FOCFOCFOCSWSWSW SW SWSWSWSWSWPOLERDIGALERTFDX - WAKVD08600 1X2 - 19167 110TH PL SE RENTON, WA 98055, USA JB0002058033REVISIONSDATEDESCRIPTIONINITIAL COMCASTSHEETOFDATE:EXCEPT AS MAY BE OTHERWISE PROVIDED BY CONTRACT,THESE DRAWINGS AND SPECIFICATIONS SHALL REMAIN THEPROPERTY OF SEFNCO COMMUNICATION, INC. BOTH BEINGISSUED IN STRICT CONFIDENCE AND SHALL NOT BEREPRODUCED, COPIED, OR USED FOR ANY PURPOSEWITHOUT SPECIFIC WRITTEN PERMISSION.SITE NAME:SCALELOCATION ADDRESS: COMCAST JOB NUMBER: STAMPDRAWN BY:GAR02/13/2025WAKVD08500 1X2 (WAKVD05500 2X4)REVISIONSDATEDESCRIPTIONINITIALTEMPORARY TRAFFICCONTROL PLANTRAFFIC CONTROL PLAN-728ADVANCED WARNING SIGN SPACINGROAD TYPESPEEDDISTANCE BETWEEN ADVANCEDWARNING SIGNSXXXXFREEWAYS & EXPRESSWAYS55/75 MPH1500 ±1500 ±1500 ±1500 ±RURAL HIGHWAYS60/65 MPH800 ±800 ±800 ±800 ±RURAL ROADS45/55 MPH500 ±500 ±500 ±500 ±RURAL ROADS & URBANARTERIAL35/40 MPH350 ±350 ±350 ±N/ARURAL ROADS, RESIDENTIAL &BUSINESS DISTRICTS25/30 MPH200 ± (2)200 ± (2)200 ± (2)N/AURBAN STREETS25 MPH ORLESS100 ± (2)100 ± (2)100 ± (2)N/A(1) ALL SPACING MAY BE ADJUSTED TO ACCOMMODATE INTERCHANGE RAMPS,AT-GRADE INTERSECTIONS, AND DRIVEWAYS.(2) THIS SPACING MAY BE REDUCED IN URBAN AREAS TO FIT ROADWAY CONDITIONS.LONGITUDINAL BUFFER SPACE =LBSSPEED (MPH)2025303540455055606570DISTANCE (FT)115155200250305360425495570645730TAPER LENGTH IN FEET=L (FEET)LANEWIDTH(FEET)POSTED SPEED LIMIT (MPH)2530354045505560657010105150205270450500550---11115160225295495550605660--121251802453205406006607207808407WARNING SIGNREGULATORY SIGNTRAFFIC CONEFLAGGER STATIONPATROL CARPOLICEOFFICERPOLICE OFFICERWORK VEHICLELIT INTERSECTIONUNLIT INTERSECTIONSPOTTER STATIONKEEPRIGHT TCP DEVICE LEGENDFASFLASHING ARROWFLASHING DOUBLE ARROW(MERGE LEFT OR RIGHT)FLASHING CAUTIONFASFASFASTRAFFIC CONTROL PLAN GENERAL NOTES1.AN ARROWBOARD SHALL MEET THE MINIMUM SIZE,LEGIBILITY DISTANCE, NUMBER OF ELEMENTS ANDOTHER SPECIFICATIONS SHOWN.2.LENGTH OF ARROW EQUALS 48", WIDTH OFARROWHEAD EQUALS 24".3.TYPE A, B AND C ARROW BOARDS SHALL HAVESOLID RECTANGULAR APPEARANCES. A TYPE DARROW BOARD SHALL CONFORM TO THE SHAPE OFTHE ARROW.4.MAINTAIN DRIVEWAY ACCESS AT ALL TIMES5.SIDEWALK ARE EITHER OPEN OR NOT OPEN. ASIDEWALK IS CLOSED IF A MINIMUM 5' PATH CANNOTBE MAINTAINED MEASURED FROM PROPERTY LINE,OR 5.5' IF CREATED FROM FACE OF CURB.(PEDESTRIAN PATH PROVIDED WHERE REQUIRED)AND WILL BE MONITORED BY A SPOTTER TOENSURE FLOW AND SAFETY DURING WORK UNLESSOTHERWISE NOTED. A SPOTTER SHALL NOT DIRECTTRAFFIC.6.NO EXCEPTION TAKEN- CONTRACTOR ISRESPONSIBLE FOR ADA COMPLIANCE.7.ALL CONTROL SET-UP, SIGN SPACING ANDPROCEDURES. WILL CONFORM TO SPECIFICATIONSSTATED IN THE FEDERAL MANUAL ON UNIFORMEDTRAFFIC CONTROL DEVICES (M.U.T.C.D).8.CITIES AND VARIOUS MUNICIPALITIES MAY HAVEALSO ADOPTED SPECIALIZED GUIDELINES FORTRAFFIC CONTROL WITHIN THEIR JURISDICTION. ITIS THE RESPONSIBILITY OF THE ON-SITE TRAFFICCONTROL PERSONAL TO SEE IF AND ANY SPECIALCONDITIONS EXIST.9.FLAGGERS SHALL BE USED IN ACCORDANCE WITHWAC 468-95-302.10.IF ONLY ONE LANE IS OPEN IN A DIRECTION,THATLANE SHALL BE A MINIMUM OF 11' WIDE, UNLESSSPOTTER/FLAGGERS ARE USED, IN WHICH CASETHE LANE CAN BE A MINIMUM OF 10'.11.ALL ROW WORK MUST YIELD TO SCHOOL TRANSIT,EMPLOYEES AND CHILDREN. WHILE PASSENGERLOADING/UNLOADING, STOPPED OR SLOWING:CEASE WORK, YIELD. WHEN SCHOOL TRANSIT,AND/OR PEDESTRIANS, DEPART COMMENCE WORK.NFASXROADWORKAHEADRIGHTLANECLOSEDAHEADXXX ROADWORKAHEADLIMITSPEEDR2-125XROADWORKAHEAD LIMIT SPEEDR2-1 25 X ROADWORKAHEADLIMITSPEEDR2-125SPOTTERSPOTTERLIMITSPEEDR2-125MFP25001055 R/WR/WR/WR/WR/WR/WR/WR/W R/W R/W R/WFOCFOCFO CFOC R/WR/WR/WR/WR/WR/WR/WR/WR/WR/W R/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WPEOP FOC FOC FOCFOCFOCFOCFOC FOC FOCFOC1015919218101131011910112192131920219208102ND AVE SE 102ND AVE SE SE 192ND PLSE 192ND PL101ST AVE SE(PRIVATE RD) 101ST PL SE (PRIVATE RD) EOPFOCFOCFOCFOC SW SW SW SWSWSWSWPOLE RDIGALERTFDX - WAKVD08600 1X2 - 19167 110TH PL SE RENTON, WA 98055, USA JB0002058033REVISIONSDATEDESCRIPTIONINITIAL COMCASTSHEETOFDATE:EXCEPT AS MAY BE OTHERWISE PROVIDED BY CONTRACT,THESE DRAWINGS AND SPECIFICATIONS SHALL REMAIN THEPROPERTY OF SEFNCO COMMUNICATION, INC. BOTH BEINGISSUED IN STRICT CONFIDENCE AND SHALL NOT BEREPRODUCED, COPIED, OR USED FOR ANY PURPOSEWITHOUT SPECIFIC WRITTEN PERMISSION.SITE NAME:SCALELOCATION ADDRESS: COMCAST JOB NUMBER: STAMPDRAWN BY:GAR02/13/2025WAKVD08500 1X2 (WAKVD05500 2X4)REVISIONSDATEDESCRIPTIONINITIALTEMPORARY TRAFFICCONTROL PLANTRAFFIC CONTROL PLAN-828ADVANCED WARNING SIGN SPACINGROAD TYPESPEEDDISTANCE BETWEEN ADVANCEDWARNING SIGNSXXXXFREEWAYS & EXPRESSWAYS55/75 MPH1500 ±1500 ±1500 ±1500 ±RURAL HIGHWAYS60/65 MPH800 ±800 ±800 ±800 ±RURAL ROADS45/55 MPH500 ±500 ±500 ±500 ±RURAL ROADS & URBANARTERIAL35/40 MPH350 ±350 ±350 ±N/ARURAL ROADS, RESIDENTIAL &BUSINESS DISTRICTS25/30 MPH200 ± (2)200 ± (2)200 ± (2)N/AURBAN STREETS25 MPH ORLESS100 ± (2)100 ± (2)100 ± (2)N/A(1) ALL SPACING MAY BE ADJUSTED TO ACCOMMODATE INTERCHANGE RAMPS,AT-GRADE INTERSECTIONS, AND DRIVEWAYS.(2) THIS SPACING MAY BE REDUCED IN URBAN AREAS TO FIT ROADWAY CONDITIONS.LONGITUDINAL BUFFER SPACE =LBSSPEED (MPH)2025303540455055606570DISTANCE (FT)115155200250305360425495570645730TAPER LENGTH IN FEET=L (FEET)LANEWIDTH(FEET)POSTED SPEED LIMIT (MPH)2530354045505560657010105150205270450500550---11115160225295495550605660--121251802453205406006607207808408WARNING SIGNREGULATORY SIGNTRAFFIC CONEFLAGGER STATIONPATROL CARPOLICEOFFICERPOLICE OFFICERWORK VEHICLELIT INTERSECTIONUNLIT INTERSECTIONSPOTTER STATIONKEEPRIGHT TCP DEVICE LEGENDFASFLASHING ARROWFLASHING DOUBLE ARROW(MERGE LEFT OR RIGHT)FLASHING CAUTIONFASFASFASTRAFFIC CONTROL PLAN GENERAL NOTES1.AN ARROWBOARD SHALL MEET THE MINIMUM SIZE,LEGIBILITY DISTANCE, NUMBER OF ELEMENTS ANDOTHER SPECIFICATIONS SHOWN.2.LENGTH OF ARROW EQUALS 48", WIDTH OFARROWHEAD EQUALS 24".3.TYPE A, B AND C ARROW BOARDS SHALL HAVESOLID RECTANGULAR APPEARANCES. A TYPE DARROW BOARD SHALL CONFORM TO THE SHAPE OFTHE ARROW.4.MAINTAIN DRIVEWAY ACCESS AT ALL TIMES5.SIDEWALK ARE EITHER OPEN OR NOT OPEN. ASIDEWALK IS CLOSED IF A MINIMUM 5' PATH CANNOTBE MAINTAINED MEASURED FROM PROPERTY LINE,OR 5.5' IF CREATED FROM FACE OF CURB.(PEDESTRIAN PATH PROVIDED WHERE REQUIRED)AND WILL BE MONITORED BY A SPOTTER TOENSURE FLOW AND SAFETY DURING WORK UNLESSOTHERWISE NOTED. A SPOTTER SHALL NOT DIRECTTRAFFIC.6.NO EXCEPTION TAKEN- CONTRACTOR ISRESPONSIBLE FOR ADA COMPLIANCE.7.ALL CONTROL SET-UP, SIGN SPACING ANDPROCEDURES. WILL CONFORM TO SPECIFICATIONSSTATED IN THE FEDERAL MANUAL ON UNIFORMEDTRAFFIC CONTROL DEVICES (M.U.T.C.D).8.CITIES AND VARIOUS MUNICIPALITIES MAY HAVEALSO ADOPTED SPECIALIZED GUIDELINES FORTRAFFIC CONTROL WITHIN THEIR JURISDICTION. ITIS THE RESPONSIBILITY OF THE ON-SITE TRAFFICCONTROL PERSONAL TO SEE IF AND ANY SPECIALCONDITIONS EXIST.9.FLAGGERS SHALL BE USED IN ACCORDANCE WITHWAC 468-95-302.10.IF ONLY ONE LANE IS OPEN IN A DIRECTION,THATLANE SHALL BE A MINIMUM OF 11' WIDE, UNLESSSPOTTER/FLAGGERS ARE USED, IN WHICH CASETHE LANE CAN BE A MINIMUM OF 10'.11.ALL ROW WORK MUST YIELD TO SCHOOL TRANSIT,EMPLOYEES AND CHILDREN. WHILE PASSENGERLOADING/UNLOADING, STOPPED OR SLOWING:CEASE WORK, YIELD. WHEN SCHOOL TRANSIT,AND/OR PEDESTRIANS, DEPART COMMENCE WORK.NXROADWORKAHEAD LIMIT SPEEDR2-1 25SPOTTERXXXROADWORKAHEADSHOULDERWORKRIGHTSHOULDERCLOSEDLIMITSPEEDR2-125TOW-AWAY AREA RCW 46 55 113 NOTE:ADJACENT BUSINESSES AND/OR RESIDENT'SWILL BE NOTIFIED IN WRITING 72 HOURS PRIORTO PLACEMENT OF "NO PARKING" SIGNS.TOW-AWAY AREA RCW 46 55 113 SPOTTER 20'TOW-AWAY AREA RCW 46 55 113TOW-AWAY AREA RCW 46 55 113NOTE:ADJACENT BUSINESSES AND/OR RESIDENT'SWILL BE NOTIFIED IN WRITING 72 HOURS PRIORTO PLACEMENT OF "NO PARKING" SIGNS.MFP25001055 R/WR/WR/WR/WR/WR/WR/WR/W R/W R/W R/W FOCFOCFOCFOC R/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WPEOP FOC FOCFOCFOCFOCFOC 10159192181011310119101121921319208102ND AVE SE 102ND AVE SE SE 192ND PLSE 192ND PL101ST PL SE(PRIVATE RD) EOPEOPFOCFOCFOCFOC SW SW SWSWSWSWPOLE RDIGALERTFDX - WAKVD08600 1X2 - 19167 110TH PL SE RENTON, WA 98055, USA JB0002058033REVISIONSDATEDESCRIPTIONINITIAL COMCASTSHEETOFDATE:EXCEPT AS MAY BE OTHERWISE PROVIDED BY CONTRACT,THESE DRAWINGS AND SPECIFICATIONS SHALL REMAIN THEPROPERTY OF SEFNCO COMMUNICATION, INC. BOTH BEINGISSUED IN STRICT CONFIDENCE AND SHALL NOT BEREPRODUCED, COPIED, OR USED FOR ANY PURPOSEWITHOUT SPECIFIC WRITTEN PERMISSION.SITE NAME:SCALELOCATION ADDRESS: COMCAST JOB NUMBER: STAMPDRAWN BY:GAR02/13/2025WAKVD08500 1X2 (WAKVD05500 2X4)REVISIONSDATEDESCRIPTIONINITIALTEMPORARY TRAFFICCONTROL PLANTRAFFIC CONTROL PLAN-928ADVANCED WARNING SIGN SPACINGROAD TYPESPEEDDISTANCE BETWEEN ADVANCEDWARNING SIGNSXXXXFREEWAYS & EXPRESSWAYS55/75 MPH1500 ±1500 ±1500 ±1500 ±RURAL HIGHWAYS60/65 MPH800 ±800 ±800 ±800 ±RURAL ROADS45/55 MPH500 ±500 ±500 ±500 ±RURAL ROADS & URBANARTERIAL35/40 MPH350 ±350 ±350 ±N/ARURAL ROADS, RESIDENTIAL &BUSINESS DISTRICTS25/30 MPH200 ± (2)200 ± (2)200 ± (2)N/AURBAN STREETS25 MPH ORLESS100 ± (2)100 ± (2)100 ± (2)N/A(1) ALL SPACING MAY BE ADJUSTED TO ACCOMMODATE INTERCHANGE RAMPS,AT-GRADE INTERSECTIONS, AND DRIVEWAYS.(2) THIS SPACING MAY BE REDUCED IN URBAN AREAS TO FIT ROADWAY CONDITIONS.LONGITUDINAL BUFFER SPACE =LBSSPEED (MPH)2025303540455055606570DISTANCE (FT)115155200250305360425495570645730TAPER LENGTH IN FEET=L (FEET)LANEWIDTH(FEET)POSTED SPEED LIMIT (MPH)2530354045505560657010105150205270450500550---11115160225295495550605660--121251802453205406006607207808409WARNING SIGNREGULATORY SIGNTRAFFIC CONEFLAGGER STATIONPATROL CARPOLICEOFFICERPOLICE OFFICERWORK VEHICLELIT INTERSECTIONUNLIT INTERSECTIONSPOTTER STATIONKEEPRIGHT TCP DEVICE LEGENDFASFLASHING ARROWFLASHING DOUBLE ARROW(MERGE LEFT OR RIGHT)FLASHING CAUTIONFASFASFASTRAFFIC CONTROL PLAN GENERAL NOTES1.AN ARROWBOARD SHALL MEET THE MINIMUM SIZE,LEGIBILITY DISTANCE, NUMBER OF ELEMENTS ANDOTHER SPECIFICATIONS SHOWN.2.LENGTH OF ARROW EQUALS 48", WIDTH OFARROWHEAD EQUALS 24".3.TYPE A, B AND C ARROW BOARDS SHALL HAVESOLID RECTANGULAR APPEARANCES. A TYPE DARROW BOARD SHALL CONFORM TO THE SHAPE OFTHE ARROW.4.MAINTAIN DRIVEWAY ACCESS AT ALL TIMES5.SIDEWALK ARE EITHER OPEN OR NOT OPEN. ASIDEWALK IS CLOSED IF A MINIMUM 5' PATH CANNOTBE MAINTAINED MEASURED FROM PROPERTY LINE,OR 5.5' IF CREATED FROM FACE OF CURB.(PEDESTRIAN PATH PROVIDED WHERE REQUIRED)AND WILL BE MONITORED BY A SPOTTER TOENSURE FLOW AND SAFETY DURING WORK UNLESSOTHERWISE NOTED. A SPOTTER SHALL NOT DIRECTTRAFFIC.6.NO EXCEPTION TAKEN- CONTRACTOR ISRESPONSIBLE FOR ADA COMPLIANCE.7.ALL CONTROL SET-UP, SIGN SPACING ANDPROCEDURES. WILL CONFORM TO SPECIFICATIONSSTATED IN THE FEDERAL MANUAL ON UNIFORMEDTRAFFIC CONTROL DEVICES (M.U.T.C.D).8.CITIES AND VARIOUS MUNICIPALITIES MAY HAVEALSO ADOPTED SPECIALIZED GUIDELINES FORTRAFFIC CONTROL WITHIN THEIR JURISDICTION. ITIS THE RESPONSIBILITY OF THE ON-SITE TRAFFICCONTROL PERSONAL TO SEE IF AND ANY SPECIALCONDITIONS EXIST.9.FLAGGERS SHALL BE USED IN ACCORDANCE WITHWAC 468-95-302.10.IF ONLY ONE LANE IS OPEN IN A DIRECTION,THATLANE SHALL BE A MINIMUM OF 11' WIDE, UNLESSSPOTTER/FLAGGERS ARE USED, IN WHICH CASETHE LANE CAN BE A MINIMUM OF 10'.11.ALL ROW WORK MUST YIELD TO SCHOOL TRANSIT,EMPLOYEES AND CHILDREN. WHILE PASSENGERLOADING/UNLOADING, STOPPED OR SLOWING:CEASE WORK, YIELD. WHEN SCHOOL TRANSIT,AND/OR PEDESTRIANS, DEPART COMMENCE WORK.NX ROADWORKAHEADLIMITSPEEDR2-125SPOTTERXXX ROADWORKAHEADSHOULDERWORKRIGHTSHOULDERCLOSEDLIMITSPEEDR2-12520'TOW-AWAY AREA RCW 46 55 113NOTE:ADJACENT BUSINESSES AND/OR RESIDENT'SWILL BE NOTIFIED IN WRITING 72 HOURS PRIORTO PLACEMENT OF "NO PARKING" SIGNS.SPOTTERTOW-AWAY AREA RCW 46 55 113XROADWORKAHEADLIMITSPEEDR2-125MFP25001055 R/WR/W R/W R/WR/WR/WR/WR/W R/WR/W FLFLFLFLFLFLFLFL FL FL FLFLFLFLFLFLFL FLFLFLFLFLFL FL FL FLFLFLFLFLFLFLEOP R/W R/W19211192101920310003750SE 1 9 2 N D S TS 55TH ST99TH PL S EOPEOPEOP EOPEOPEOPS 55TH STPOLE PO L E RDIGALERTFDX - WAKVD08600 1X2 - 19167 110TH PL SE RENTON, WA 98055, USA JB0002058033REVISIONSDATEDESCRIPTIONINITIAL COMCASTSHEETOFDATE:EXCEPT AS MAY BE OTHERWISE PROVIDED BY CONTRACT,THESE DRAWINGS AND SPECIFICATIONS SHALL REMAIN THEPROPERTY OF SEFNCO COMMUNICATION, INC. BOTH BEINGISSUED IN STRICT CONFIDENCE AND SHALL NOT BEREPRODUCED, COPIED, OR USED FOR ANY PURPOSEWITHOUT SPECIFIC WRITTEN PERMISSION.SITE NAME:SCALELOCATION ADDRESS: COMCAST JOB NUMBER: STAMPDRAWN BY:GAR02/13/2025WAKVD08500 1X2 (WAKVD05500 2X4)REVISIONSDATEDESCRIPTIONINITIALTEMPORARY TRAFFICCONTROL PLANTRAFFIC CONTROL PLAN-1028ADVANCED WARNING SIGN SPACINGROAD TYPESPEEDDISTANCE BETWEEN ADVANCEDWARNING SIGNSXXXXFREEWAYS & EXPRESSWAYS55/75 MPH1500 ±1500 ±1500 ±1500 ±RURAL HIGHWAYS60/65 MPH800 ±800 ±800 ±800 ±RURAL ROADS45/55 MPH500 ±500 ±500 ±500 ±RURAL ROADS & URBANARTERIAL35/40 MPH350 ±350 ±350 ±N/ARURAL ROADS, RESIDENTIAL &BUSINESS DISTRICTS25/30 MPH200 ± (2)200 ± (2)200 ± (2)N/AURBAN STREETS25 MPH ORLESS100 ± (2)100 ± (2)100 ± (2)N/A(1) ALL SPACING MAY BE ADJUSTED TO ACCOMMODATE INTERCHANGE RAMPS,AT-GRADE INTERSECTIONS, AND DRIVEWAYS.(2) THIS SPACING MAY BE REDUCED IN URBAN AREAS TO FIT ROADWAY CONDITIONS.LONGITUDINAL BUFFER SPACE =LBSSPEED (MPH)2025303540455055606570DISTANCE (FT)115155200250305360425495570645730TAPER LENGTH IN FEET=L (FEET)LANEWIDTH(FEET)POSTED SPEED LIMIT (MPH)2530354045505560657010105150205270450500550---11115160225295495550605660--1212518024532054060066072078084010WARNING SIGNREGULATORY SIGNTRAFFIC CONEFLAGGER STATIONPATROL CARPOLICEOFFICERPOLICE OFFICERWORK VEHICLELIT INTERSECTIONUNLIT INTERSECTIONSPOTTER STATIONKEEPRIGHT TCP DEVICE LEGENDFASFLASHING ARROWFLASHING DOUBLE ARROW(MERGE LEFT OR RIGHT)FLASHING CAUTIONFASFASFASTRAFFIC CONTROL PLAN GENERAL NOTES1.AN ARROWBOARD SHALL MEET THE MINIMUM SIZE,LEGIBILITY DISTANCE, NUMBER OF ELEMENTS ANDOTHER SPECIFICATIONS SHOWN.2.LENGTH OF ARROW EQUALS 48", WIDTH OFARROWHEAD EQUALS 24".3.TYPE A, B AND C ARROW BOARDS SHALL HAVESOLID RECTANGULAR APPEARANCES. A TYPE DARROW BOARD SHALL CONFORM TO THE SHAPE OFTHE ARROW.4.MAINTAIN DRIVEWAY ACCESS AT ALL TIMES5.SIDEWALK ARE EITHER OPEN OR NOT OPEN. ASIDEWALK IS CLOSED IF A MINIMUM 5' PATH CANNOTBE MAINTAINED MEASURED FROM PROPERTY LINE,OR 5.5' IF CREATED FROM FACE OF CURB.(PEDESTRIAN PATH PROVIDED WHERE REQUIRED)AND WILL BE MONITORED BY A SPOTTER TOENSURE FLOW AND SAFETY DURING WORK UNLESSOTHERWISE NOTED. A SPOTTER SHALL NOT DIRECTTRAFFIC.6.NO EXCEPTION TAKEN- CONTRACTOR ISRESPONSIBLE FOR ADA COMPLIANCE.7.ALL CONTROL SET-UP, SIGN SPACING ANDPROCEDURES. WILL CONFORM TO SPECIFICATIONSSTATED IN THE FEDERAL MANUAL ON UNIFORMEDTRAFFIC CONTROL DEVICES (M.U.T.C.D).8.CITIES AND VARIOUS MUNICIPALITIES MAY HAVEALSO ADOPTED SPECIALIZED GUIDELINES FORTRAFFIC CONTROL WITHIN THEIR JURISDICTION. ITIS THE RESPONSIBILITY OF THE ON-SITE TRAFFICCONTROL PERSONAL TO SEE IF AND ANY SPECIALCONDITIONS EXIST.9.FLAGGERS SHALL BE USED IN ACCORDANCE WITHWAC 468-95-302.10.IF ONLY ONE LANE IS OPEN IN A DIRECTION,THATLANE SHALL BE A MINIMUM OF 11' WIDE, UNLESSSPOTTER/FLAGGERS ARE USED, IN WHICH CASETHE LANE CAN BE A MINIMUM OF 10'.11.ALL ROW WORK MUST YIELD TO SCHOOL TRANSIT,EMPLOYEES AND CHILDREN. WHILE PASSENGERLOADING/UNLOADING, STOPPED OR SLOWING:CEASE WORK, YIELD. WHEN SCHOOL TRANSIT,AND/OR PEDESTRIANS, DEPART COMMENCE WORK.NX ROADWORKAHEADLIMITSPEEDR2-125X X X ROADWORKAHEADSHOULDERWORKRIGHTSHOULDERCLOSEDLIMITSPEEDR2-125XROADWORKAHEADLIMITSPEEDR2-125SPOTTERMFP25001055 R/WR/WR/W R/W R/W R/WR/WR/WR/W R/W R/WR/WR/WR/W R/WR/W FOCFOC FLFLFLFL FL FL FLFLFLFLFLFLFLFL FLFLFLFL FL FLFLFLFLFLEOPR/W1921119219 19218192101920310003SE 1 9 2 N D S TS 55TH ST99TH PL S EOPEOPEOPEOPEOPS 55TH ST POLE PO L E RDIGALERTFDX - WAKVD08600 1X2 - 19167 110TH PL SE RENTON, WA 98055, USA JB0002058033REVISIONSDATEDESCRIPTIONINITIAL COMCASTSHEETOFDATE:EXCEPT AS MAY BE OTHERWISE PROVIDED BY CONTRACT,THESE DRAWINGS AND SPECIFICATIONS SHALL REMAIN THEPROPERTY OF SEFNCO COMMUNICATION, INC. BOTH BEINGISSUED IN STRICT CONFIDENCE AND SHALL NOT BEREPRODUCED, COPIED, OR USED FOR ANY PURPOSEWITHOUT SPECIFIC WRITTEN PERMISSION.SITE NAME:SCALELOCATION ADDRESS: COMCAST JOB NUMBER: STAMPDRAWN BY:GAR02/13/2025WAKVD08500 1X2 (WAKVD05500 2X4)REVISIONSDATEDESCRIPTIONINITIALTEMPORARY TRAFFICCONTROL PLANTRAFFIC CONTROL PLAN-1128ADVANCED WARNING SIGN SPACINGROAD TYPESPEEDDISTANCE BETWEEN ADVANCEDWARNING SIGNSXXXXFREEWAYS & EXPRESSWAYS55/75 MPH1500 ±1500 ±1500 ±1500 ±RURAL HIGHWAYS60/65 MPH800 ±800 ±800 ±800 ±RURAL ROADS45/55 MPH500 ±500 ±500 ±500 ±RURAL ROADS & URBANARTERIAL35/40 MPH350 ±350 ±350 ±N/ARURAL ROADS, RESIDENTIAL &BUSINESS DISTRICTS25/30 MPH200 ± (2)200 ± (2)200 ± (2)N/AURBAN STREETS25 MPH ORLESS100 ± (2)100 ± (2)100 ± (2)N/A(1) ALL SPACING MAY BE ADJUSTED TO ACCOMMODATE INTERCHANGE RAMPS,AT-GRADE INTERSECTIONS, AND DRIVEWAYS.(2) THIS SPACING MAY BE REDUCED IN URBAN AREAS TO FIT ROADWAY CONDITIONS.LONGITUDINAL BUFFER SPACE =LBSSPEED (MPH)2025303540455055606570DISTANCE (FT)115155200250305360425495570645730TAPER LENGTH IN FEET=L (FEET)LANEWIDTH(FEET)POSTED SPEED LIMIT (MPH)2530354045505560657010105150205270450500550---11115160225295495550605660--1212518024532054060066072078084011WARNING SIGNREGULATORY SIGNTRAFFIC CONEFLAGGER STATIONPATROL CARPOLICEOFFICERPOLICE OFFICERWORK VEHICLELIT INTERSECTIONUNLIT INTERSECTIONSPOTTER STATIONKEEPRIGHT TCP DEVICE LEGENDFASFLASHING ARROWFLASHING DOUBLE ARROW(MERGE LEFT OR RIGHT)FLASHING CAUTIONFASFASFASTRAFFIC CONTROL PLAN GENERAL NOTES1.AN ARROWBOARD SHALL MEET THE MINIMUM SIZE,LEGIBILITY DISTANCE, NUMBER OF ELEMENTS ANDOTHER SPECIFICATIONS SHOWN.2.LENGTH OF ARROW EQUALS 48", WIDTH OFARROWHEAD EQUALS 24".3.TYPE A, B AND C ARROW BOARDS SHALL HAVESOLID RECTANGULAR APPEARANCES. A TYPE DARROW BOARD SHALL CONFORM TO THE SHAPE OFTHE ARROW.4.MAINTAIN DRIVEWAY ACCESS AT ALL TIMES5.SIDEWALK ARE EITHER OPEN OR NOT OPEN. ASIDEWALK IS CLOSED IF A MINIMUM 5' PATH CANNOTBE MAINTAINED MEASURED FROM PROPERTY LINE,OR 5.5' IF CREATED FROM FACE OF CURB.(PEDESTRIAN PATH PROVIDED WHERE REQUIRED)AND WILL BE MONITORED BY A SPOTTER TOENSURE FLOW AND SAFETY DURING WORK UNLESSOTHERWISE NOTED. A SPOTTER SHALL NOT DIRECTTRAFFIC.6.NO EXCEPTION TAKEN- CONTRACTOR ISRESPONSIBLE FOR ADA COMPLIANCE.7.ALL CONTROL SET-UP, SIGN SPACING ANDPROCEDURES. WILL CONFORM TO SPECIFICATIONSSTATED IN THE FEDERAL MANUAL ON UNIFORMEDTRAFFIC CONTROL DEVICES (M.U.T.C.D).8.CITIES AND VARIOUS MUNICIPALITIES MAY HAVEALSO ADOPTED SPECIALIZED GUIDELINES FORTRAFFIC CONTROL WITHIN THEIR JURISDICTION. ITIS THE RESPONSIBILITY OF THE ON-SITE TRAFFICCONTROL PERSONAL TO SEE IF AND ANY SPECIALCONDITIONS EXIST.9.FLAGGERS SHALL BE USED IN ACCORDANCE WITHWAC 468-95-302.10.IF ONLY ONE LANE IS OPEN IN A DIRECTION,THATLANE SHALL BE A MINIMUM OF 11' WIDE, UNLESSSPOTTER/FLAGGERS ARE USED, IN WHICH CASETHE LANE CAN BE A MINIMUM OF 10'.11.ALL ROW WORK MUST YIELD TO SCHOOL TRANSIT,EMPLOYEES AND CHILDREN. WHILE PASSENGERLOADING/UNLOADING, STOPPED OR SLOWING:CEASE WORK, YIELD. WHEN SCHOOL TRANSIT,AND/OR PEDESTRIANS, DEPART COMMENCE WORK.NX ROADWORKAHEADLIMITSPEEDR2-125XXXROADWORKAHEADSHOULDERWORKRIGHTSHOULDERCLOSEDLIMITSPEEDR2-125X ROADWORKAHEADLIMITSPEEDR2-12520'TOW-A WA Y AR E A R C W 4 6 55 1 1 3TOW-AWAY A R E A R C W 46 55 113NOTE:ADJACENT BUSINESSES AND/OR RESIDENT'SWILL BE NOTIFIED IN WRITING 72 HOURS PRIORTO PLACEMENT OF "NO PARKING" SIGNS.SPOTTERMFP25001055 R/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/W R/WFOCFOCR/WR/WR/WR/WFLFLFLFLFLFLFLFLFLFLFOCFOCFOCFOCFOCFOCR/WFOCFOC FOCFOCR/W R/WR/WR/WEOPEOPEOPFLFLFL FL FL FLFLFLFL FL FL FLFLFLFLFLFLFLFLFLFLFLFLFLFLFLEOPEOPEOPEOPEOPS 55TH STS 55TH STS 55TH ST 98TH AVE S965119203520498496192001921819212EOPEOPPR/W R/W SWSWSWSWSWSWPOLERDIGALERTFDX - WAKVD08600 1X2 - 19167 110TH PL SE RENTON, WA 98055, USA JB0002058033REVISIONSDATEDESCRIPTIONINITIAL COMCASTSHEETOFDATE:EXCEPT AS MAY BE OTHERWISE PROVIDED BY CONTRACT,THESE DRAWINGS AND SPECIFICATIONS SHALL REMAIN THEPROPERTY OF SEFNCO COMMUNICATION, INC. BOTH BEINGISSUED IN STRICT CONFIDENCE AND SHALL NOT BEREPRODUCED, COPIED, OR USED FOR ANY PURPOSEWITHOUT SPECIFIC WRITTEN PERMISSION.SITE NAME:SCALELOCATION ADDRESS: COMCAST JOB NUMBER: STAMPDRAWN BY:GAR02/13/2025WAKVD08500 1X2 (WAKVD05500 2X4)REVISIONSDATEDESCRIPTIONINITIALTEMPORARY TRAFFICCONTROL PLANTRAFFIC CONTROL PLAN-1228ADVANCED WARNING SIGN SPACINGROAD TYPESPEEDDISTANCE BETWEEN ADVANCEDWARNING SIGNSXXXXFREEWAYS & EXPRESSWAYS55/75 MPH1500 ±1500 ±1500 ±1500 ±RURAL HIGHWAYS60/65 MPH800 ±800 ±800 ±800 ±RURAL ROADS45/55 MPH500 ±500 ±500 ±500 ±RURAL ROADS & URBANARTERIAL35/40 MPH350 ±350 ±350 ±N/ARURAL ROADS, RESIDENTIAL &BUSINESS DISTRICTS25/30 MPH200 ± (2)200 ± (2)200 ± (2)N/AURBAN STREETS25 MPH ORLESS100 ± (2)100 ± (2)100 ± (2)N/A(1) ALL SPACING MAY BE ADJUSTED TO ACCOMMODATE INTERCHANGE RAMPS,AT-GRADE INTERSECTIONS, AND DRIVEWAYS.(2) THIS SPACING MAY BE REDUCED IN URBAN AREAS TO FIT ROADWAY CONDITIONS.LONGITUDINAL BUFFER SPACE =LBSSPEED (MPH)2025303540455055606570DISTANCE (FT)115155200250305360425495570645730TAPER LENGTH IN FEET=L (FEET)LANEWIDTH(FEET)POSTED SPEED LIMIT (MPH)2530354045505560657010105150205270450500550---11115160225295495550605660--1212518024532054060066072078084012WARNING SIGNREGULATORY SIGNTRAFFIC CONEFLAGGER STATIONPATROL CARPOLICEOFFICERPOLICE OFFICERWORK VEHICLELIT INTERSECTIONUNLIT INTERSECTIONSPOTTER STATIONKEEPRIGHT TCP DEVICE LEGENDFASFLASHING ARROWFLASHING DOUBLE ARROW(MERGE LEFT OR RIGHT)FLASHING CAUTIONFASFASFASTRAFFIC CONTROL PLAN GENERAL NOTES1.AN ARROWBOARD SHALL MEET THE MINIMUM SIZE,LEGIBILITY DISTANCE, NUMBER OF ELEMENTS ANDOTHER SPECIFICATIONS SHOWN.2.LENGTH OF ARROW EQUALS 48", WIDTH OFARROWHEAD EQUALS 24".3.TYPE A, B AND C ARROW BOARDS SHALL HAVESOLID RECTANGULAR APPEARANCES. A TYPE DARROW BOARD SHALL CONFORM TO THE SHAPE OFTHE ARROW.4.MAINTAIN DRIVEWAY ACCESS AT ALL TIMES5.SIDEWALK ARE EITHER OPEN OR NOT OPEN. ASIDEWALK IS CLOSED IF A MINIMUM 5' PATH CANNOTBE MAINTAINED MEASURED FROM PROPERTY LINE,OR 5.5' IF CREATED FROM FACE OF CURB.(PEDESTRIAN PATH PROVIDED WHERE REQUIRED)AND WILL BE MONITORED BY A SPOTTER TOENSURE FLOW AND SAFETY DURING WORK UNLESSOTHERWISE NOTED. A SPOTTER SHALL NOT DIRECTTRAFFIC.6.NO EXCEPTION TAKEN- CONTRACTOR ISRESPONSIBLE FOR ADA COMPLIANCE.7.ALL CONTROL SET-UP, SIGN SPACING ANDPROCEDURES. WILL CONFORM TO SPECIFICATIONSSTATED IN THE FEDERAL MANUAL ON UNIFORMEDTRAFFIC CONTROL DEVICES (M.U.T.C.D).8.CITIES AND VARIOUS MUNICIPALITIES MAY HAVEALSO ADOPTED SPECIALIZED GUIDELINES FORTRAFFIC CONTROL WITHIN THEIR JURISDICTION. ITIS THE RESPONSIBILITY OF THE ON-SITE TRAFFICCONTROL PERSONAL TO SEE IF AND ANY SPECIALCONDITIONS EXIST.9.FLAGGERS SHALL BE USED IN ACCORDANCE WITHWAC 468-95-302.10.IF ONLY ONE LANE IS OPEN IN A DIRECTION,THATLANE SHALL BE A MINIMUM OF 11' WIDE, UNLESSSPOTTER/FLAGGERS ARE USED, IN WHICH CASETHE LANE CAN BE A MINIMUM OF 10'.11.ALL ROW WORK MUST YIELD TO SCHOOL TRANSIT,EMPLOYEES AND CHILDREN. WHILE PASSENGERLOADING/UNLOADING, STOPPED OR SLOWING:CEASE WORK, YIELD. WHEN SCHOOL TRANSIT,AND/OR PEDESTRIANS, DEPART COMMENCE WORK.NXXXROADWORKAHEADONELANEROADAHEADLIMITSPEEDR2-125FLAGGERXXXROADWORKAHEAD ONELANEROADAHEAD FLAGGERSPOTTER LIMITSPEED R2-1 25XXXROADWORKAHEADONELANEROADAHEADFLAGGERLIM ITSPEED R2-125MFP25001055 R/WR/WR/WR/WR/WR/W R/ W R/ W R/WR/WR/WR/WR/WR/W R/WR/WR/WR/WR/WR/WR/WR/WR/W R/WFLFLFLFLFLFLFLFLFOC FOC FOCFOCFOCFOCFOCFOCFOCR/WFOC FOCFOCFOCFOC FOC FOCFOCR/W R/W R/WR/WR/WEOPEOPEOPFLFLFLFLFLFLFL FL FL FL FLFLFLFLFLF LFL FL FL FL FLFLFLFLFLFLFLFLFLFLFLEOPEOPEOP EOPEOPEOPEOP S 55T H S TS 55TH STS 55TH STS 55TH ST 98TH AVE S965119203EOPPR/W R/W SWSWSWSWPOLE 98TH PL S(PRIVATE RD)RDIGALERTFDX - WAKVD08600 1X2 - 19167 110TH PL SE RENTON, WA 98055, USA JB0002058033REVISIONSDATEDESCRIPTIONINITIAL COMCASTSHEETOFDATE:EXCEPT AS MAY BE OTHERWISE PROVIDED BY CONTRACT,THESE DRAWINGS AND SPECIFICATIONS SHALL REMAIN THEPROPERTY OF SEFNCO COMMUNICATION, INC. BOTH BEINGISSUED IN STRICT CONFIDENCE AND SHALL NOT BEREPRODUCED, COPIED, OR USED FOR ANY PURPOSEWITHOUT SPECIFIC WRITTEN PERMISSION.SITE NAME:SCALELOCATION ADDRESS: COMCAST JOB NUMBER: STAMPDRAWN BY:GAR02/13/2025WAKVD08500 1X2 (WAKVD05500 2X4)REVISIONSDATEDESCRIPTIONINITIALTEMPORARY TRAFFICCONTROL PLANTRAFFIC CONTROL PLAN-1328ADVANCED WARNING SIGN SPACINGROAD TYPESPEEDDISTANCE BETWEEN ADVANCEDWARNING SIGNSXXXXFREEWAYS & EXPRESSWAYS55/75 MPH1500 ±1500 ±1500 ±1500 ±RURAL HIGHWAYS60/65 MPH800 ±800 ±800 ±800 ±RURAL ROADS45/55 MPH500 ±500 ±500 ±500 ±RURAL ROADS & URBANARTERIAL35/40 MPH350 ±350 ±350 ±N/ARURAL ROADS, RESIDENTIAL &BUSINESS DISTRICTS25/30 MPH200 ± (2)200 ± (2)200 ± (2)N/AURBAN STREETS25 MPH ORLESS100 ± (2)100 ± (2)100 ± (2)N/A(1) ALL SPACING MAY BE ADJUSTED TO ACCOMMODATE INTERCHANGE RAMPS,AT-GRADE INTERSECTIONS, AND DRIVEWAYS.(2) THIS SPACING MAY BE REDUCED IN URBAN AREAS TO FIT ROADWAY CONDITIONS.LONGITUDINAL BUFFER SPACE =LBSSPEED (MPH)2025303540455055606570DISTANCE (FT)115155200250305360425495570645730TAPER LENGTH IN FEET=L (FEET)LANEWIDTH(FEET)POSTED SPEED LIMIT (MPH)2530354045505560657010105150205270450500550---11115160225295495550605660--1212518024532054060066072078084013WARNING SIGNREGULATORY SIGNTRAFFIC CONEFLAGGER STATIONPATROL CARPOLICEOFFICERPOLICE OFFICERWORK VEHICLELIT INTERSECTIONUNLIT INTERSECTIONSPOTTER STATIONKEEPRIGHT TCP DEVICE LEGENDFASFLASHING ARROWFLASHING DOUBLE ARROW(MERGE LEFT OR RIGHT)FLASHING CAUTIONFASFASFASTRAFFIC CONTROL PLAN GENERAL NOTES1.AN ARROWBOARD SHALL MEET THE MINIMUM SIZE,LEGIBILITY DISTANCE, NUMBER OF ELEMENTS ANDOTHER SPECIFICATIONS SHOWN.2.LENGTH OF ARROW EQUALS 48", WIDTH OFARROWHEAD EQUALS 24".3.TYPE A, B AND C ARROW BOARDS SHALL HAVESOLID RECTANGULAR APPEARANCES. A TYPE DARROW BOARD SHALL CONFORM TO THE SHAPE OFTHE ARROW.4.MAINTAIN DRIVEWAY ACCESS AT ALL TIMES5.SIDEWALK ARE EITHER OPEN OR NOT OPEN. ASIDEWALK IS CLOSED IF A MINIMUM 5' PATH CANNOTBE MAINTAINED MEASURED FROM PROPERTY LINE,OR 5.5' IF CREATED FROM FACE OF CURB.(PEDESTRIAN PATH PROVIDED WHERE REQUIRED)AND WILL BE MONITORED BY A SPOTTER TOENSURE FLOW AND SAFETY DURING WORK UNLESSOTHERWISE NOTED. A SPOTTER SHALL NOT DIRECTTRAFFIC.6.NO EXCEPTION TAKEN- CONTRACTOR ISRESPONSIBLE FOR ADA COMPLIANCE.7.ALL CONTROL SET-UP, SIGN SPACING ANDPROCEDURES. WILL CONFORM TO SPECIFICATIONSSTATED IN THE FEDERAL MANUAL ON UNIFORMEDTRAFFIC CONTROL DEVICES (M.U.T.C.D).8.CITIES AND VARIOUS MUNICIPALITIES MAY HAVEALSO ADOPTED SPECIALIZED GUIDELINES FORTRAFFIC CONTROL WITHIN THEIR JURISDICTION. ITIS THE RESPONSIBILITY OF THE ON-SITE TRAFFICCONTROL PERSONAL TO SEE IF AND ANY SPECIALCONDITIONS EXIST.9.FLAGGERS SHALL BE USED IN ACCORDANCE WITHWAC 468-95-302.10.IF ONLY ONE LANE IS OPEN IN A DIRECTION,THATLANE SHALL BE A MINIMUM OF 11' WIDE, UNLESSSPOTTER/FLAGGERS ARE USED, IN WHICH CASETHE LANE CAN BE A MINIMUM OF 10'.11.ALL ROW WORK MUST YIELD TO SCHOOL TRANSIT,EMPLOYEES AND CHILDREN. WHILE PASSENGERLOADING/UNLOADING, STOPPED OR SLOWING:CEASE WORK, YIELD. WHEN SCHOOL TRANSIT,AND/OR PEDESTRIANS, DEPART COMMENCE WORK.NXXXROADWORKAHEADONELANEROADAHEADLIMITSPEEDR2-125FLAGGERXXXROADWORKAHEAD ONELANEROADAHEAD FLAGGERSPOTTER LIMITSPEED R2-1 25 X X ROADWORKAHEADONELANEROADAHEADFLAGGERLIMITSPEEDR2-125X 12' FLAG G E R 98TH AVE S MFP25001055 R/W R/W R/W R/W R/WP R/WR/WR/WR/WR/WR/WR/WR/WFOC FOCR/WR/WR/WR/WR/WR/W R/WR/WR/WR/WR/WR/WR/WR/WFL FL FL FL FL FL FL FL FL R/WR/W FL FL FL FL FL FL FL FL FL FL FL 97TH AVE SEOPEOPEOPEOPFOCFOCFOCF O C FOC EOPSWSW SWSWSWSWSW SW POLE 2RDIGALERTFDX - WAKVD08600 1X2 - 19167 110TH PL SE RENTON, WA 98055, USA JB0002058033REVISIONSDATEDESCRIPTIONINITIAL COMCASTSHEETOFDATE:EXCEPT AS MAY BE OTHERWISE PROVIDED BY CONTRACT,THESE DRAWINGS AND SPECIFICATIONS SHALL REMAIN THEPROPERTY OF SEFNCO COMMUNICATION, INC. BOTH BEINGISSUED IN STRICT CONFIDENCE AND SHALL NOT BEREPRODUCED, COPIED, OR USED FOR ANY PURPOSEWITHOUT SPECIFIC WRITTEN PERMISSION.SITE NAME:SCALELOCATION ADDRESS: COMCAST JOB NUMBER: STAMPDRAWN BY:GAR02/13/2025WAKVD08500 1X2 (WAKVD05500 2X4)REVISIONSDATEDESCRIPTIONINITIALTEMPORARY TRAFFICCONTROL PLANTRAFFIC CONTROL PLAN-1428ADVANCED WARNING SIGN SPACINGROAD TYPESPEEDDISTANCE BETWEEN ADVANCEDWARNING SIGNSXXXXFREEWAYS & EXPRESSWAYS55/75 MPH1500 ±1500 ±1500 ±1500 ±RURAL HIGHWAYS60/65 MPH800 ±800 ±800 ±800 ±RURAL ROADS45/55 MPH500 ±500 ±500 ±500 ±RURAL ROADS & URBANARTERIAL35/40 MPH350 ±350 ±350 ±N/ARURAL ROADS, RESIDENTIAL &BUSINESS DISTRICTS25/30 MPH200 ± (2)200 ± (2)200 ± (2)N/AURBAN STREETS25 MPH ORLESS100 ± (2)100 ± (2)100 ± (2)N/A(1) ALL SPACING MAY BE ADJUSTED TO ACCOMMODATE INTERCHANGE RAMPS,AT-GRADE INTERSECTIONS, AND DRIVEWAYS.(2) THIS SPACING MAY BE REDUCED IN URBAN AREAS TO FIT ROADWAY CONDITIONS.LONGITUDINAL BUFFER SPACE =LBSSPEED (MPH)2025303540455055606570DISTANCE (FT)115155200250305360425495570645730TAPER LENGTH IN FEET=L (FEET)LANEWIDTH(FEET)POSTED SPEED LIMIT (MPH)2530354045505560657010105150205270450500550---11115160225295495550605660--1212518024532054060066072078084014WARNING SIGNREGULATORY SIGNTRAFFIC CONEFLAGGER STATIONPATROL CARPOLICEOFFICERPOLICE OFFICERWORK VEHICLELIT INTERSECTIONUNLIT INTERSECTIONSPOTTER STATIONKEEPRIGHT TCP DEVICE LEGENDFASFLASHING ARROWFLASHING DOUBLE ARROW(MERGE LEFT OR RIGHT)FLASHING CAUTIONFASFASFASTRAFFIC CONTROL PLAN GENERAL NOTES1.AN ARROWBOARD SHALL MEET THE MINIMUM SIZE,LEGIBILITY DISTANCE, NUMBER OF ELEMENTS ANDOTHER SPECIFICATIONS SHOWN.2.LENGTH OF ARROW EQUALS 48", WIDTH OFARROWHEAD EQUALS 24".3.TYPE A, B AND C ARROW BOARDS SHALL HAVESOLID RECTANGULAR APPEARANCES. A TYPE DARROW BOARD SHALL CONFORM TO THE SHAPE OFTHE ARROW.4.MAINTAIN DRIVEWAY ACCESS AT ALL TIMES5.SIDEWALK ARE EITHER OPEN OR NOT OPEN. ASIDEWALK IS CLOSED IF A MINIMUM 5' PATH CANNOTBE MAINTAINED MEASURED FROM PROPERTY LINE,OR 5.5' IF CREATED FROM FACE OF CURB.(PEDESTRIAN PATH PROVIDED WHERE REQUIRED)AND WILL BE MONITORED BY A SPOTTER TOENSURE FLOW AND SAFETY DURING WORK UNLESSOTHERWISE NOTED. A SPOTTER SHALL NOT DIRECTTRAFFIC.6.NO EXCEPTION TAKEN- CONTRACTOR ISRESPONSIBLE FOR ADA COMPLIANCE.7.ALL CONTROL SET-UP, SIGN SPACING ANDPROCEDURES. WILL CONFORM TO SPECIFICATIONSSTATED IN THE FEDERAL MANUAL ON UNIFORMEDTRAFFIC CONTROL DEVICES (M.U.T.C.D).8.CITIES AND VARIOUS MUNICIPALITIES MAY HAVEALSO ADOPTED SPECIALIZED GUIDELINES FORTRAFFIC CONTROL WITHIN THEIR JURISDICTION. ITIS THE RESPONSIBILITY OF THE ON-SITE TRAFFICCONTROL PERSONAL TO SEE IF AND ANY SPECIALCONDITIONS EXIST.9.FLAGGERS SHALL BE USED IN ACCORDANCE WITHWAC 468-95-302.10.IF ONLY ONE LANE IS OPEN IN A DIRECTION,THATLANE SHALL BE A MINIMUM OF 11' WIDE, UNLESSSPOTTER/FLAGGERS ARE USED, IN WHICH CASETHE LANE CAN BE A MINIMUM OF 10'.11.ALL ROW WORK MUST YIELD TO SCHOOL TRANSIT,EMPLOYEES AND CHILDREN. WHILE PASSENGERLOADING/UNLOADING, STOPPED OR SLOWING:CEASE WORK, YIELD. WHEN SCHOOL TRANSIT,AND/OR PEDESTRIANS, DEPART COMMENCE WORK.NTOW-AWAY AREA RCW 46 55 113NOTE:ADJACENT BUSINESSES AND/OR RESIDENT'SWILL BE NOTIFIED IN WRITING 72 HOURS PRIORTO PLACEMENT OF "NO PARKING" SIGNS.496S 55TH ST S 55TH ST19200 960919225192241921819212192315420TOW-AWAY AREA RCW 46 55 113 SPOTTERSPOTTER XXXROADWORKAHEADSHOULDERWORKRIGHTSHOULDERCLOSEDLIMITSPEEDR2-125XROADWORKAHEAD LIMITSPEED R2-1 25 MFP25001055 R/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WA A A A A A A AAAAAAAAAAAFOCFOCFOCFOCFOC FOC FOCR/WR/WR/WR/WR/WR/WR/WR/W R/WFLFLFLFLFL FLR/WR/WR/WR/WR/WR/WR/WR/WFOCFOCR/WR/WR/WR/W R/W R/W FLFLFLFL FL FL FL FLFLFLFLFLFLFLFLFLFLFLFLFOCR/WFOC FOC FLFLFLFLFLFLFLFLFLFLFL496S 55TH STS 192ND STTALBOT RD STALBOT RD S 97TH AVE S 192001920196091922519212EOP EOP EOPEOPEOPEOPEOPEOPEOPEOPFOC FOC FOC124'108'9'200'54209533S 55TH ST (PRIVATE RD)SWSWSW SW SW SW SWSWSWSW SW SW SW SWPOLE 1POLE 2POLE 3 RDIGALERTFDX - WAKVD08600 1X2 - 19167 110TH PL SE RENTON, WA 98055, USA JB0002058033REVISIONSDATEDESCRIPTIONINITIAL COMCASTSHEETOFDATE:EXCEPT AS MAY BE OTHERWISE PROVIDED BY CONTRACT,THESE DRAWINGS AND SPECIFICATIONS SHALL REMAIN THEPROPERTY OF SEFNCO COMMUNICATION, INC. BOTH BEINGISSUED IN STRICT CONFIDENCE AND SHALL NOT BEREPRODUCED, COPIED, OR USED FOR ANY PURPOSEWITHOUT SPECIFIC WRITTEN PERMISSION.SITE NAME:SCALELOCATION ADDRESS: COMCAST JOB NUMBER: STAMPDRAWN BY:GAR02/13/2025WAKVD08500 1X2 (WAKVD05500 2X4)REVISIONSDATEDESCRIPTIONINITIALTEMPORARY TRAFFICCONTROL PLANTRAFFIC CONTROL PLAN-1528ADVANCED WARNING SIGN SPACINGROAD TYPESPEEDDISTANCE BETWEEN ADVANCEDWARNING SIGNSXXXXFREEWAYS & EXPRESSWAYS55/75 MPH1500 ±1500 ±1500 ±1500 ±RURAL HIGHWAYS60/65 MPH800 ±800 ±800 ±800 ±RURAL ROADS45/55 MPH500 ±500 ±500 ±500 ±RURAL ROADS & URBANARTERIAL35/40 MPH350 ±350 ±350 ±N/ARURAL ROADS, RESIDENTIAL &BUSINESS DISTRICTS25/30 MPH200 ± (2)200 ± (2)200 ± (2)N/AURBAN STREETS25 MPH ORLESS100 ± (2)100 ± (2)100 ± (2)N/A(1) ALL SPACING MAY BE ADJUSTED TO ACCOMMODATE INTERCHANGE RAMPS,AT-GRADE INTERSECTIONS, AND DRIVEWAYS.(2) THIS SPACING MAY BE REDUCED IN URBAN AREAS TO FIT ROADWAY CONDITIONS.LONGITUDINAL BUFFER SPACE =LBSSPEED (MPH)2025303540455055606570DISTANCE (FT)115155200250305360425495570645730TAPER LENGTH IN FEET=L (FEET)LANEWIDTH(FEET)POSTED SPEED LIMIT (MPH)2530354045505560657010105150205270450500550---11115160225295495550605660--1212518024532054060066072078084015WARNING SIGNREGULATORY SIGNTRAFFIC CONEFLAGGER STATIONPATROL CARPOLICEOFFICERPOLICE OFFICERWORK VEHICLELIT INTERSECTIONUNLIT INTERSECTIONSPOTTER STATIONKEEPRIGHT TCP DEVICE LEGENDFASFLASHING ARROWFLASHING DOUBLE ARROW(MERGE LEFT OR RIGHT)FLASHING CAUTIONFASFASFASTRAFFIC CONTROL PLAN GENERAL NOTES1.AN ARROWBOARD SHALL MEET THE MINIMUM SIZE,LEGIBILITY DISTANCE, NUMBER OF ELEMENTS ANDOTHER SPECIFICATIONS SHOWN.2.LENGTH OF ARROW EQUALS 48", WIDTH OFARROWHEAD EQUALS 24".3.TYPE A, B AND C ARROW BOARDS SHALL HAVESOLID RECTANGULAR APPEARANCES. A TYPE DARROW BOARD SHALL CONFORM TO THE SHAPE OFTHE ARROW.4.MAINTAIN DRIVEWAY ACCESS AT ALL TIMES5.SIDEWALK ARE EITHER OPEN OR NOT OPEN. ASIDEWALK IS CLOSED IF A MINIMUM 5' PATH CANNOTBE MAINTAINED MEASURED FROM PROPERTY LINE,OR 5.5' IF CREATED FROM FACE OF CURB.(PEDESTRIAN PATH PROVIDED WHERE REQUIRED)AND WILL BE MONITORED BY A SPOTTER TOENSURE FLOW AND SAFETY DURING WORK UNLESSOTHERWISE NOTED. A SPOTTER SHALL NOT DIRECTTRAFFIC.6.NO EXCEPTION TAKEN- CONTRACTOR ISRESPONSIBLE FOR ADA COMPLIANCE.7.ALL CONTROL SET-UP, SIGN SPACING ANDPROCEDURES. WILL CONFORM TO SPECIFICATIONSSTATED IN THE FEDERAL MANUAL ON UNIFORMEDTRAFFIC CONTROL DEVICES (M.U.T.C.D).8.CITIES AND VARIOUS MUNICIPALITIES MAY HAVEALSO ADOPTED SPECIALIZED GUIDELINES FORTRAFFIC CONTROL WITHIN THEIR JURISDICTION. ITIS THE RESPONSIBILITY OF THE ON-SITE TRAFFICCONTROL PERSONAL TO SEE IF AND ANY SPECIALCONDITIONS EXIST.9.FLAGGERS SHALL BE USED IN ACCORDANCE WITHWAC 468-95-302.10.IF ONLY ONE LANE IS OPEN IN A DIRECTION,THATLANE SHALL BE A MINIMUM OF 11' WIDE, UNLESSSPOTTER/FLAGGERS ARE USED, IN WHICH CASETHE LANE CAN BE A MINIMUM OF 10'.11.ALL ROW WORK MUST YIELD TO SCHOOL TRANSIT,EMPLOYEES AND CHILDREN. WHILE PASSENGERLOADING/UNLOADING, STOPPED OR SLOWING:CEASE WORK, YIELD. WHEN SCHOOL TRANSIT,AND/OR PEDESTRIANS, DEPART COMMENCE WORK.NSPOTTER SPOTTERXXXROADWORKAHEADSHOULDERWORKRIGHTSHOULDERCLOSEDLIMITSPEEDR2-125XROADWORKAHEAD LIMIT SPEEDR2-1 25 X ROADWORKAHEADLIMITSPEEDR2-125S 55TH STMFP25001055 R/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WA A A A A A A AAAAAAAAAAAFOCFOCFOCFOCFOC FOC FOCR/WR/WR/WR/WR/WR/WR/WR/WR/W R/WFLFLFLFLFL FLR/WR/WR/WR/WR/WR/WR/WR/WFOCFOCR/WR/WR/WR/W R/W R/W FLFLFLFL FL FL FL FLFLFLFLFLFLFLFLFLFLFLFLFOCR/WFOC FOC FLFLFLFLFLFLFLFLFLFLFL496S 55TH STS 192ND STTALBOT RD STALBOT RD S 97TH AVE S 192001920196091922519212EOP EOP EOPEOPEOPEOPEOPEOPEOPEOPFOC FOC FOC FOC124'108'9'200'54209533S 55TH ST (PRIVATE RD)SWSWSWSW SW SW SWSWSWSW SW SW SW SWPOLE 1POLE 2POLE 3 RDIGALERTFDX - WAKVD08600 1X2 - 19167 110TH PL SE RENTON, WA 98055, USA JB0002058033REVISIONSDATEDESCRIPTIONINITIAL COMCASTSHEETOFDATE:EXCEPT AS MAY BE OTHERWISE PROVIDED BY CONTRACT,THESE DRAWINGS AND SPECIFICATIONS SHALL REMAIN THEPROPERTY OF SEFNCO COMMUNICATION, INC. BOTH BEINGISSUED IN STRICT CONFIDENCE AND SHALL NOT BEREPRODUCED, COPIED, OR USED FOR ANY PURPOSEWITHOUT SPECIFIC WRITTEN PERMISSION.SITE NAME:SCALELOCATION ADDRESS: COMCAST JOB NUMBER: STAMPDRAWN BY:GAR02/13/2025WAKVD08500 1X2 (WAKVD05500 2X4)REVISIONSDATEDESCRIPTIONINITIALTEMPORARY TRAFFICCONTROL PLANTRAFFIC CONTROL PLAN-1628ADVANCED WARNING SIGN SPACINGROAD TYPESPEEDDISTANCE BETWEEN ADVANCEDWARNING SIGNSXXXXFREEWAYS & EXPRESSWAYS55/75 MPH1500 ±1500 ±1500 ±1500 ±RURAL HIGHWAYS60/65 MPH800 ±800 ±800 ±800 ±RURAL ROADS45/55 MPH500 ±500 ±500 ±500 ±RURAL ROADS & URBANARTERIAL35/40 MPH350 ±350 ±350 ±N/ARURAL ROADS, RESIDENTIAL &BUSINESS DISTRICTS25/30 MPH200 ± (2)200 ± (2)200 ± (2)N/AURBAN STREETS25 MPH ORLESS100 ± (2)100 ± (2)100 ± (2)N/A(1) ALL SPACING MAY BE ADJUSTED TO ACCOMMODATE INTERCHANGE RAMPS,AT-GRADE INTERSECTIONS, AND DRIVEWAYS.(2) THIS SPACING MAY BE REDUCED IN URBAN AREAS TO FIT ROADWAY CONDITIONS.LONGITUDINAL BUFFER SPACE =LBSSPEED (MPH)2025303540455055606570DISTANCE (FT)115155200250305360425495570645730TAPER LENGTH IN FEET=L (FEET)LANEWIDTH(FEET)POSTED SPEED LIMIT (MPH)2530354045505560657010105150205270450500550---11115160225295495550605660--1212518024532054060066072078084016WARNING SIGNREGULATORY SIGNTRAFFIC CONEFLAGGER STATIONPATROL CARPOLICEOFFICERPOLICE OFFICERWORK VEHICLELIT INTERSECTIONUNLIT INTERSECTIONSPOTTER STATIONKEEPRIGHT TCP DEVICE LEGENDFASFLASHING ARROWFLASHING DOUBLE ARROW(MERGE LEFT OR RIGHT)FLASHING CAUTIONFASFASFASTRAFFIC CONTROL PLAN GENERAL NOTES1.AN ARROWBOARD SHALL MEET THE MINIMUM SIZE,LEGIBILITY DISTANCE, NUMBER OF ELEMENTS ANDOTHER SPECIFICATIONS SHOWN.2.LENGTH OF ARROW EQUALS 48", WIDTH OFARROWHEAD EQUALS 24".3.TYPE A, B AND C ARROW BOARDS SHALL HAVESOLID RECTANGULAR APPEARANCES. A TYPE DARROW BOARD SHALL CONFORM TO THE SHAPE OFTHE ARROW.4.MAINTAIN DRIVEWAY ACCESS AT ALL TIMES5.SIDEWALK ARE EITHER OPEN OR NOT OPEN. ASIDEWALK IS CLOSED IF A MINIMUM 5' PATH CANNOTBE MAINTAINED MEASURED FROM PROPERTY LINE,OR 5.5' IF CREATED FROM FACE OF CURB.(PEDESTRIAN PATH PROVIDED WHERE REQUIRED)AND WILL BE MONITORED BY A SPOTTER TOENSURE FLOW AND SAFETY DURING WORK UNLESSOTHERWISE NOTED. A SPOTTER SHALL NOT DIRECTTRAFFIC.6.NO EXCEPTION TAKEN- CONTRACTOR ISRESPONSIBLE FOR ADA COMPLIANCE.7.ALL CONTROL SET-UP, SIGN SPACING ANDPROCEDURES. WILL CONFORM TO SPECIFICATIONSSTATED IN THE FEDERAL MANUAL ON UNIFORMEDTRAFFIC CONTROL DEVICES (M.U.T.C.D).8.CITIES AND VARIOUS MUNICIPALITIES MAY HAVEALSO ADOPTED SPECIALIZED GUIDELINES FORTRAFFIC CONTROL WITHIN THEIR JURISDICTION. ITIS THE RESPONSIBILITY OF THE ON-SITE TRAFFICCONTROL PERSONAL TO SEE IF AND ANY SPECIALCONDITIONS EXIST.9.FLAGGERS SHALL BE USED IN ACCORDANCE WITHWAC 468-95-302.10.IF ONLY ONE LANE IS OPEN IN A DIRECTION,THATLANE SHALL BE A MINIMUM OF 11' WIDE, UNLESSSPOTTER/FLAGGERS ARE USED, IN WHICH CASETHE LANE CAN BE A MINIMUM OF 10'.11.ALL ROW WORK MUST YIELD TO SCHOOL TRANSIT,EMPLOYEES AND CHILDREN. WHILE PASSENGERLOADING/UNLOADING, STOPPED OR SLOWING:CEASE WORK, YIELD. WHEN SCHOOL TRANSIT,AND/OR PEDESTRIANS, DEPART COMMENCE WORK.NSPOTTER SPOTTERS 55TH STXXXROADWORKAHEAD ONELANEROADAHEAD FLAGGERXXXROADWORKAHEADONELANEROADAHEADFLAGGERXXX ROADWORKAHEADONELANEROADAHEADLIMITSPEEDR2-125FLAGGERX X XROADWORKAHEADONELANEROADAHEAD FLAGGERXXX ROADWORKAHEADONELANEROADAHEADFLAGGERLIMITSPEEDR2-125LIMIT SPEED R2-1 25 LIMITSPEEDR2-135LIMITSPEEDR2-135SPOTTER MFP25001055 R/W R/W R/W R/WR/WR/WR/WR/WR/WR/WR/W R/WAAAAAAAAAAAA FOCFOCFOCFOC FOCFOCFOCFOCFOCFOCFOCFOCFOCR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WFLFLFLFLFLFLFLFLFLFLFLFLFLR/WR/WR/WFL FL FL FL FL FLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFOCFOCR/WR/WR/WR/WFOCFOCFOC FL FL FL FLS 192ND ST TALBOT RD STALBOT RD SEOPEOPEOPFOCEOP EOPEOPEOPEOP EOP108'9'200'AAAAAAAAA108'S 55TH ST (PRIVATE RD)SWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWPOLE 3POLE 2POLE 49533RDIGALERTFDX - WAKVD08600 1X2 - 19167 110TH PL SE RENTON, WA 98055, USA JB0002058033REVISIONSDATEDESCRIPTIONINITIAL COMCASTSHEETOFDATE:EXCEPT AS MAY BE OTHERWISE PROVIDED BY CONTRACT,THESE DRAWINGS AND SPECIFICATIONS SHALL REMAIN THEPROPERTY OF SEFNCO COMMUNICATION, INC. BOTH BEINGISSUED IN STRICT CONFIDENCE AND SHALL NOT BEREPRODUCED, COPIED, OR USED FOR ANY PURPOSEWITHOUT SPECIFIC WRITTEN PERMISSION.SITE NAME:SCALELOCATION ADDRESS: COMCAST JOB NUMBER: STAMPDRAWN BY:GAR02/13/2025WAKVD08500 1X2 (WAKVD05500 2X4)REVISIONSDATEDESCRIPTIONINITIALTEMPORARY TRAFFICCONTROL PLANTRAFFIC CONTROL PLAN-1728ADVANCED WARNING SIGN SPACINGROAD TYPESPEEDDISTANCE BETWEEN ADVANCEDWARNING SIGNSXXXXFREEWAYS & EXPRESSWAYS55/75 MPH1500 ±1500 ±1500 ±1500 ±RURAL HIGHWAYS60/65 MPH800 ±800 ±800 ±800 ±RURAL ROADS45/55 MPH500 ±500 ±500 ±500 ±RURAL ROADS & URBANARTERIAL35/40 MPH350 ±350 ±350 ±N/ARURAL ROADS, RESIDENTIAL &BUSINESS DISTRICTS25/30 MPH200 ± (2)200 ± (2)200 ± (2)N/AURBAN STREETS25 MPH ORLESS100 ± (2)100 ± (2)100 ± (2)N/A(1) ALL SPACING MAY BE ADJUSTED TO ACCOMMODATE INTERCHANGE RAMPS,AT-GRADE INTERSECTIONS, AND DRIVEWAYS.(2) THIS SPACING MAY BE REDUCED IN URBAN AREAS TO FIT ROADWAY CONDITIONS.LONGITUDINAL BUFFER SPACE =LBSSPEED (MPH)2025303540455055606570DISTANCE (FT)115155200250305360425495570645730TAPER LENGTH IN FEET=L (FEET)LANEWIDTH(FEET)POSTED SPEED LIMIT (MPH)2530354045505560657010105150205270450500550---11115160225295495550605660--1212518024532054060066072078084017WARNING SIGNREGULATORY SIGNTRAFFIC CONEFLAGGER STATIONPATROL CARPOLICEOFFICERPOLICE OFFICERWORK VEHICLELIT INTERSECTIONUNLIT INTERSECTIONSPOTTER STATIONKEEPRIGHT TCP DEVICE LEGENDFASFLASHING ARROWFLASHING DOUBLE ARROW(MERGE LEFT OR RIGHT)FLASHING CAUTIONFASFASFASTRAFFIC CONTROL PLAN GENERAL NOTES1.AN ARROWBOARD SHALL MEET THE MINIMUM SIZE,LEGIBILITY DISTANCE, NUMBER OF ELEMENTS ANDOTHER SPECIFICATIONS SHOWN.2.LENGTH OF ARROW EQUALS 48", WIDTH OFARROWHEAD EQUALS 24".3.TYPE A, B AND C ARROW BOARDS SHALL HAVESOLID RECTANGULAR APPEARANCES. A TYPE DARROW BOARD SHALL CONFORM TO THE SHAPE OFTHE ARROW.4.MAINTAIN DRIVEWAY ACCESS AT ALL TIMES5.SIDEWALK ARE EITHER OPEN OR NOT OPEN. ASIDEWALK IS CLOSED IF A MINIMUM 5' PATH CANNOTBE MAINTAINED MEASURED FROM PROPERTY LINE,OR 5.5' IF CREATED FROM FACE OF CURB.(PEDESTRIAN PATH PROVIDED WHERE REQUIRED)AND WILL BE MONITORED BY A SPOTTER TOENSURE FLOW AND SAFETY DURING WORK UNLESSOTHERWISE NOTED. A SPOTTER SHALL NOT DIRECTTRAFFIC.6.NO EXCEPTION TAKEN- CONTRACTOR ISRESPONSIBLE FOR ADA COMPLIANCE.7.ALL CONTROL SET-UP, SIGN SPACING ANDPROCEDURES. WILL CONFORM TO SPECIFICATIONSSTATED IN THE FEDERAL MANUAL ON UNIFORMEDTRAFFIC CONTROL DEVICES (M.U.T.C.D).8.CITIES AND VARIOUS MUNICIPALITIES MAY HAVEALSO ADOPTED SPECIALIZED GUIDELINES FORTRAFFIC CONTROL WITHIN THEIR JURISDICTION. ITIS THE RESPONSIBILITY OF THE ON-SITE TRAFFICCONTROL PERSONAL TO SEE IF AND ANY SPECIALCONDITIONS EXIST.9.FLAGGERS SHALL BE USED IN ACCORDANCE WITHWAC 468-95-302.10.IF ONLY ONE LANE IS OPEN IN A DIRECTION,THATLANE SHALL BE A MINIMUM OF 11' WIDE, UNLESSSPOTTER/FLAGGERS ARE USED, IN WHICH CASETHE LANE CAN BE A MINIMUM OF 10'.11.ALL ROW WORK MUST YIELD TO SCHOOL TRANSIT,EMPLOYEES AND CHILDREN. WHILE PASSENGERLOADING/UNLOADING, STOPPED OR SLOWING:CEASE WORK, YIELD. WHEN SCHOOL TRANSIT,AND/OR PEDESTRIANS, DEPART COMMENCE WORK.NXXXROADWORKAHEAD ONELANEROADAHEAD FLAGGERXXXROADWORKAHEADONELANEROADAHEADFLAGGERXXXROADWORKAHEADONELANEROADAHEADFLAGGER XXX ROADWORKAHEADONELANEROADAHEADFLAGGERS 55TH ST NOTE:AERIAL CROSSING TIME WILL BEAPPROXIMATE 5 MIN.SPOTTER LIMITSPEEDR2-125LIMITSPEEDR2-125LIMITSPEED R2-1 35LIMITSPEEDR2-135MFP25001055 R/WA A A A A A A AAAAAAAA AR/WR/WR/WR/WR/WR/WR/W R/W FL FL FL FL FL FLFLFLFLFLFLFLFL FL R/WR/WR/WR/WR/WR/W R/W R/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WFLFL FOCFOCFOCFOCFOCTALBOT RD STALBOT RD S S 194TH STS 194TH ST9612961596339640FOCFOCFOC FOCFOCFOCEOP EOP EOP169'224'EOP EOP SWSW SWSWSWSWSWSWSWSWSW SW SW SW SW SWSWSWSWSWSWSW POLE 5POLE 6 RDIGALERTFDX - WAKVD08600 1X2 - 19167 110TH PL SE RENTON, WA 98055, USA JB0002058033REVISIONSDATEDESCRIPTIONINITIAL COMCASTSHEETOFDATE:EXCEPT AS MAY BE OTHERWISE PROVIDED BY CONTRACT,THESE DRAWINGS AND SPECIFICATIONS SHALL REMAIN THEPROPERTY OF SEFNCO COMMUNICATION, INC. BOTH BEINGISSUED IN STRICT CONFIDENCE AND SHALL NOT BEREPRODUCED, COPIED, OR USED FOR ANY PURPOSEWITHOUT SPECIFIC WRITTEN PERMISSION.SITE NAME:SCALELOCATION ADDRESS: COMCAST JOB NUMBER: STAMPDRAWN BY:GAR02/13/2025WAKVD08500 1X2 (WAKVD05500 2X4)REVISIONSDATEDESCRIPTIONINITIALTEMPORARY TRAFFICCONTROL PLANTRAFFIC CONTROL PLAN-1828ADVANCED WARNING SIGN SPACINGROAD TYPESPEEDDISTANCE BETWEEN ADVANCEDWARNING SIGNSXXXXFREEWAYS & EXPRESSWAYS55/75 MPH1500 ±1500 ±1500 ±1500 ±RURAL HIGHWAYS60/65 MPH800 ±800 ±800 ±800 ±RURAL ROADS45/55 MPH500 ±500 ±500 ±500 ±RURAL ROADS & URBANARTERIAL35/40 MPH350 ±350 ±350 ±N/ARURAL ROADS, RESIDENTIAL &BUSINESS DISTRICTS25/30 MPH200 ± (2)200 ± (2)200 ± (2)N/AURBAN STREETS25 MPH ORLESS100 ± (2)100 ± (2)100 ± (2)N/A(1) ALL SPACING MAY BE ADJUSTED TO ACCOMMODATE INTERCHANGE RAMPS,AT-GRADE INTERSECTIONS, AND DRIVEWAYS.(2) THIS SPACING MAY BE REDUCED IN URBAN AREAS TO FIT ROADWAY CONDITIONS.LONGITUDINAL BUFFER SPACE =LBSSPEED (MPH)2025303540455055606570DISTANCE (FT)115155200250305360425495570645730TAPER LENGTH IN FEET=L (FEET)LANEWIDTH(FEET)POSTED SPEED LIMIT (MPH)2530354045505560657010105150205270450500550---11115160225295495550605660--1212518024532054060066072078084018WARNING SIGNREGULATORY SIGNTRAFFIC CONEFLAGGER STATIONPATROL CARPOLICEOFFICERPOLICE OFFICERWORK VEHICLELIT INTERSECTIONUNLIT INTERSECTIONSPOTTER STATIONKEEPRIGHT TCP DEVICE LEGENDFASFLASHING ARROWFLASHING DOUBLE ARROW(MERGE LEFT OR RIGHT)FLASHING CAUTIONFASFASFASTRAFFIC CONTROL PLAN GENERAL NOTES1.AN ARROWBOARD SHALL MEET THE MINIMUM SIZE,LEGIBILITY DISTANCE, NUMBER OF ELEMENTS ANDOTHER SPECIFICATIONS SHOWN.2.LENGTH OF ARROW EQUALS 48", WIDTH OFARROWHEAD EQUALS 24".3.TYPE A, B AND C ARROW BOARDS SHALL HAVESOLID RECTANGULAR APPEARANCES. A TYPE DARROW BOARD SHALL CONFORM TO THE SHAPE OFTHE ARROW.4.MAINTAIN DRIVEWAY ACCESS AT ALL TIMES5.SIDEWALK ARE EITHER OPEN OR NOT OPEN. ASIDEWALK IS CLOSED IF A MINIMUM 5' PATH CANNOTBE MAINTAINED MEASURED FROM PROPERTY LINE,OR 5.5' IF CREATED FROM FACE OF CURB.(PEDESTRIAN PATH PROVIDED WHERE REQUIRED)AND WILL BE MONITORED BY A SPOTTER TOENSURE FLOW AND SAFETY DURING WORK UNLESSOTHERWISE NOTED. A SPOTTER SHALL NOT DIRECTTRAFFIC.6.NO EXCEPTION TAKEN- CONTRACTOR ISRESPONSIBLE FOR ADA COMPLIANCE.7.ALL CONTROL SET-UP, SIGN SPACING ANDPROCEDURES. WILL CONFORM TO SPECIFICATIONSSTATED IN THE FEDERAL MANUAL ON UNIFORMEDTRAFFIC CONTROL DEVICES (M.U.T.C.D).8.CITIES AND VARIOUS MUNICIPALITIES MAY HAVEALSO ADOPTED SPECIALIZED GUIDELINES FORTRAFFIC CONTROL WITHIN THEIR JURISDICTION. ITIS THE RESPONSIBILITY OF THE ON-SITE TRAFFICCONTROL PERSONAL TO SEE IF AND ANY SPECIALCONDITIONS EXIST.9.FLAGGERS SHALL BE USED IN ACCORDANCE WITHWAC 468-95-302.10.IF ONLY ONE LANE IS OPEN IN A DIRECTION,THATLANE SHALL BE A MINIMUM OF 11' WIDE, UNLESSSPOTTER/FLAGGERS ARE USED, IN WHICH CASETHE LANE CAN BE A MINIMUM OF 10'.11.ALL ROW WORK MUST YIELD TO SCHOOL TRANSIT,EMPLOYEES AND CHILDREN. WHILE PASSENGERLOADING/UNLOADING, STOPPED OR SLOWING:CEASE WORK, YIELD. WHEN SCHOOL TRANSIT,AND/OR PEDESTRIANS, DEPART COMMENCE WORK.NSPOTTERXXXROADWORKAHEAD ONELANEROADAHEAD FLAGGER X X X ROADWORKAHEADONELANEROADAHEADFLAGGERXXX ROADWORKAHEADONELANEROADAHEADFLAGGERLIMITSPEEDR2-135LIMIT SPEED R2-1 25 LIMITSPEEDR2-135MFP25001055 R/WR/WA A A A A A AAAAAAAAAA PR/WR/WR/WR/WR/WR/W R/W R/W FL FL FL FLFLFLFLFLFLFLFLFLFL R/WR/WR/WR/WR/W R/WR/WR/WR/WR/WR/WR/WR/W R/W R/W R/W R/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WFLFL FL FOCFOCFOCFOCTALBOT RD S S 194TH STS 194TH ST96129615963396379640FOCFOCFOC FOCFOCF O C FOCEOP EOPTALBOT RD S 169'224'EOP EOP EOPSWSWSWSWSW SWSWSWSWSW SW SW SW SWSWSWSWS WSW SWSWSWPOLE 6 RDIGALERTFDX - WAKVD08600 1X2 - 19167 110TH PL SE RENTON, WA 98055, USA JB0002058033REVISIONSDATEDESCRIPTIONINITIAL COMCASTSHEETOFDATE:EXCEPT AS MAY BE OTHERWISE PROVIDED BY CONTRACT,THESE DRAWINGS AND SPECIFICATIONS SHALL REMAIN THEPROPERTY OF SEFNCO COMMUNICATION, INC. BOTH BEINGISSUED IN STRICT CONFIDENCE AND SHALL NOT BEREPRODUCED, COPIED, OR USED FOR ANY PURPOSEWITHOUT SPECIFIC WRITTEN PERMISSION.SITE NAME:SCALELOCATION ADDRESS: COMCAST JOB NUMBER: STAMPDRAWN BY:GAR02/13/2025WAKVD08500 1X2 (WAKVD05500 2X4)REVISIONSDATEDESCRIPTIONINITIALTEMPORARY TRAFFICCONTROL PLANTRAFFIC CONTROL PLAN-1928ADVANCED WARNING SIGN SPACINGROAD TYPESPEEDDISTANCE BETWEEN ADVANCEDWARNING SIGNSXXXXFREEWAYS & EXPRESSWAYS55/75 MPH1500 ±1500 ±1500 ±1500 ±RURAL HIGHWAYS60/65 MPH800 ±800 ±800 ±800 ±RURAL ROADS45/55 MPH500 ±500 ±500 ±500 ±RURAL ROADS & URBANARTERIAL35/40 MPH350 ±350 ±350 ±N/ARURAL ROADS, RESIDENTIAL &BUSINESS DISTRICTS25/30 MPH200 ± (2)200 ± (2)200 ± (2)N/AURBAN STREETS25 MPH ORLESS100 ± (2)100 ± (2)100 ± (2)N/A(1) ALL SPACING MAY BE ADJUSTED TO ACCOMMODATE INTERCHANGE RAMPS,AT-GRADE INTERSECTIONS, AND DRIVEWAYS.(2) THIS SPACING MAY BE REDUCED IN URBAN AREAS TO FIT ROADWAY CONDITIONS.LONGITUDINAL BUFFER SPACE =LBSSPEED (MPH)2025303540455055606570DISTANCE (FT)115155200250305360425495570645730TAPER LENGTH IN FEET=L (FEET)LANEWIDTH(FEET)POSTED SPEED LIMIT (MPH)2530354045505560657010105150205270450500550---11115160225295495550605660--1212518024532054060066072078084019WARNING SIGNREGULATORY SIGNTRAFFIC CONEFLAGGER STATIONPATROL CARPOLICEOFFICERPOLICE OFFICERWORK VEHICLELIT INTERSECTIONUNLIT INTERSECTIONSPOTTER STATIONKEEPRIGHT TCP DEVICE LEGENDFASFLASHING ARROWFLASHING DOUBLE ARROW(MERGE LEFT OR RIGHT)FLASHING CAUTIONFASFASFASTRAFFIC CONTROL PLAN GENERAL NOTES1.AN ARROWBOARD SHALL MEET THE MINIMUM SIZE,LEGIBILITY DISTANCE, NUMBER OF ELEMENTS ANDOTHER SPECIFICATIONS SHOWN.2.LENGTH OF ARROW EQUALS 48", WIDTH OFARROWHEAD EQUALS 24".3.TYPE A, B AND C ARROW BOARDS SHALL HAVESOLID RECTANGULAR APPEARANCES. A TYPE DARROW BOARD SHALL CONFORM TO THE SHAPE OFTHE ARROW.4.MAINTAIN DRIVEWAY ACCESS AT ALL TIMES5.SIDEWALK ARE EITHER OPEN OR NOT OPEN. ASIDEWALK IS CLOSED IF A MINIMUM 5' PATH CANNOTBE MAINTAINED MEASURED FROM PROPERTY LINE,OR 5.5' IF CREATED FROM FACE OF CURB.(PEDESTRIAN PATH PROVIDED WHERE REQUIRED)AND WILL BE MONITORED BY A SPOTTER TOENSURE FLOW AND SAFETY DURING WORK UNLESSOTHERWISE NOTED. A SPOTTER SHALL NOT DIRECTTRAFFIC.6.NO EXCEPTION TAKEN- CONTRACTOR ISRESPONSIBLE FOR ADA COMPLIANCE.7.ALL CONTROL SET-UP, SIGN SPACING ANDPROCEDURES. WILL CONFORM TO SPECIFICATIONSSTATED IN THE FEDERAL MANUAL ON UNIFORMEDTRAFFIC CONTROL DEVICES (M.U.T.C.D).8.CITIES AND VARIOUS MUNICIPALITIES MAY HAVEALSO ADOPTED SPECIALIZED GUIDELINES FORTRAFFIC CONTROL WITHIN THEIR JURISDICTION. ITIS THE RESPONSIBILITY OF THE ON-SITE TRAFFICCONTROL PERSONAL TO SEE IF AND ANY SPECIALCONDITIONS EXIST.9.FLAGGERS SHALL BE USED IN ACCORDANCE WITHWAC 468-95-302.10.IF ONLY ONE LANE IS OPEN IN A DIRECTION,THATLANE SHALL BE A MINIMUM OF 11' WIDE, UNLESSSPOTTER/FLAGGERS ARE USED, IN WHICH CASETHE LANE CAN BE A MINIMUM OF 10'.11.ALL ROW WORK MUST YIELD TO SCHOOL TRANSIT,EMPLOYEES AND CHILDREN. WHILE PASSENGERLOADING/UNLOADING, STOPPED OR SLOWING:CEASE WORK, YIELD. WHEN SCHOOL TRANSIT,AND/OR PEDESTRIANS, DEPART COMMENCE WORK.NSPOTT E RSPOTTER XROADWORKAHEADNOTE:ADJACENT BUSINESSES AND/OR RESIDENT'SWILL BE NOTIFIED IN WRITING 72 HOURS PRIORTO PLACEMENT OF "NO PARKING" SIGNS.TOW-AWAY AREA RCW 46 55 113XXXROADWORKAHEADSHOULDERWORKRIGHTSHOULDERCLOSEDLIMITSPEEDR2-125MFP25001055 A A A A A A A A A A A A A A A A R/WR/WR/WR/WR/WFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLR/W R/W R/W EOP EOP EOP EOP EOP R/W R/W R/W R/W R/W R/W R/W R/W TALBO T R D S 179' 204' TALB O T R D S 194181946419425EOP EOP FOC FOC FOC SW POLE 8 POLE 9 RDIGALERTFDX - WAKVD08600 1X2 - 19167 110TH PL SE RENTON, WA 98055, USA JB0002058033REVISIONSDATEDESCRIPTIONINITIAL COMCASTSHEETOFDATE:EXCEPT AS MAY BE OTHERWISE PROVIDED BY CONTRACT,THESE DRAWINGS AND SPECIFICATIONS SHALL REMAIN THEPROPERTY OF SEFNCO COMMUNICATION, INC. BOTH BEINGISSUED IN STRICT CONFIDENCE AND SHALL NOT BEREPRODUCED, COPIED, OR USED FOR ANY PURPOSEWITHOUT SPECIFIC WRITTEN PERMISSION.SITE NAME:SCALELOCATION ADDRESS: COMCAST JOB NUMBER: STAMPDRAWN BY:GAR02/13/2025WAKVD08500 1X2 (WAKVD05500 2X4)REVISIONSDATEDESCRIPTIONINITIALTEMPORARY TRAFFICCONTROL PLANTRAFFIC CONTROL PLAN-2028ADVANCED WARNING SIGN SPACINGROAD TYPESPEEDDISTANCE BETWEEN ADVANCEDWARNING SIGNSXXXXFREEWAYS & EXPRESSWAYS55/75 MPH1500 ±1500 ±1500 ±1500 ±RURAL HIGHWAYS60/65 MPH800 ±800 ±800 ±800 ±RURAL ROADS45/55 MPH500 ±500 ±500 ±500 ±RURAL ROADS & URBANARTERIAL35/40 MPH350 ±350 ±350 ±N/ARURAL ROADS, RESIDENTIAL &BUSINESS DISTRICTS25/30 MPH200 ± (2)200 ± (2)200 ± (2)N/AURBAN STREETS25 MPH ORLESS100 ± (2)100 ± (2)100 ± (2)N/A(1) ALL SPACING MAY BE ADJUSTED TO ACCOMMODATE INTERCHANGE RAMPS,AT-GRADE INTERSECTIONS, AND DRIVEWAYS.(2) THIS SPACING MAY BE REDUCED IN URBAN AREAS TO FIT ROADWAY CONDITIONS.LONGITUDINAL BUFFER SPACE =LBSSPEED (MPH)2025303540455055606570DISTANCE (FT)115155200250305360425495570645730TAPER LENGTH IN FEET=L (FEET)LANEWIDTH(FEET)POSTED SPEED LIMIT (MPH)2530354045505560657010105150205270450500550---11115160225295495550605660--1212518024532054060066072078084020WARNING SIGNREGULATORY SIGNTRAFFIC CONEFLAGGER STATIONPATROL CARPOLICEOFFICERPOLICE OFFICERWORK VEHICLELIT INTERSECTIONUNLIT INTERSECTIONSPOTTER STATIONKEEPRIGHT TCP DEVICE LEGENDFASFLASHING ARROWFLASHING DOUBLE ARROW(MERGE LEFT OR RIGHT)FLASHING CAUTIONFASFASFASTRAFFIC CONTROL PLAN GENERAL NOTES1.AN ARROWBOARD SHALL MEET THE MINIMUM SIZE,LEGIBILITY DISTANCE, NUMBER OF ELEMENTS ANDOTHER SPECIFICATIONS SHOWN.2.LENGTH OF ARROW EQUALS 48", WIDTH OFARROWHEAD EQUALS 24".3.TYPE A, B AND C ARROW BOARDS SHALL HAVESOLID RECTANGULAR APPEARANCES. A TYPE DARROW BOARD SHALL CONFORM TO THE SHAPE OFTHE ARROW.4.MAINTAIN DRIVEWAY ACCESS AT ALL TIMES5.SIDEWALK ARE EITHER OPEN OR NOT OPEN. ASIDEWALK IS CLOSED IF A MINIMUM 5' PATH CANNOTBE MAINTAINED MEASURED FROM PROPERTY LINE,OR 5.5' IF CREATED FROM FACE OF CURB.(PEDESTRIAN PATH PROVIDED WHERE REQUIRED)AND WILL BE MONITORED BY A SPOTTER TOENSURE FLOW AND SAFETY DURING WORK UNLESSOTHERWISE NOTED. A SPOTTER SHALL NOT DIRECTTRAFFIC.6.NO EXCEPTION TAKEN- CONTRACTOR ISRESPONSIBLE FOR ADA COMPLIANCE.7.ALL CONTROL SET-UP, SIGN SPACING ANDPROCEDURES. WILL CONFORM TO SPECIFICATIONSSTATED IN THE FEDERAL MANUAL ON UNIFORMEDTRAFFIC CONTROL DEVICES (M.U.T.C.D).8.CITIES AND VARIOUS MUNICIPALITIES MAY HAVEALSO ADOPTED SPECIALIZED GUIDELINES FORTRAFFIC CONTROL WITHIN THEIR JURISDICTION. ITIS THE RESPONSIBILITY OF THE ON-SITE TRAFFICCONTROL PERSONAL TO SEE IF AND ANY SPECIALCONDITIONS EXIST.9.FLAGGERS SHALL BE USED IN ACCORDANCE WITHWAC 468-95-302.10.IF ONLY ONE LANE IS OPEN IN A DIRECTION,THATLANE SHALL BE A MINIMUM OF 11' WIDE, UNLESSSPOTTER/FLAGGERS ARE USED, IN WHICH CASETHE LANE CAN BE A MINIMUM OF 10'.11.ALL ROW WORK MUST YIELD TO SCHOOL TRANSIT,EMPLOYEES AND CHILDREN. WHILE PASSENGERLOADING/UNLOADING, STOPPED OR SLOWING:CEASE WORK, YIELD. WHEN SCHOOL TRANSIT,AND/OR PEDESTRIANS, DEPART COMMENCE WORK.N11'X X X ROADWORKAHEADSHOULDERWORKRIGHTSHOULDERCLOSEDX ROADWORKAHEADSPOTTERLIMITSPEEDR2-135LIMITSPEEDR2-135MFP25001055 AAAAAAAAAAAAAAAAAAAAAAAAAAAAR/WFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFOCFOCFOCFOCFO C R/W R/W R/W R/W R/WR/W R/W R/WR/WR/WR/WR/WEOPFLFLFLFLEOPEOPEOPEOPEOPEOPEOPR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/W204'215'TALBOT RD SS 196 PLFOCFOC FOC FOCFOCFOCFOCFOCFOCSWSWSWSW SW SWSWSWSWSWSWSWPOLE 9POLE 10POLE 111942594979491948519640RDIGALERTFDX - WAKVD08600 1X2 - 19167 110TH PL SE RENTON, WA 98055, USA JB0002058033REVISIONSDATEDESCRIPTIONINITIAL COMCASTSHEETOFDATE:EXCEPT AS MAY BE OTHERWISE PROVIDED BY CONTRACT,THESE DRAWINGS AND SPECIFICATIONS SHALL REMAIN THEPROPERTY OF SEFNCO COMMUNICATION, INC. BOTH BEINGISSUED IN STRICT CONFIDENCE AND SHALL NOT BEREPRODUCED, COPIED, OR USED FOR ANY PURPOSEWITHOUT SPECIFIC WRITTEN PERMISSION.SITE NAME:SCALELOCATION ADDRESS: COMCAST JOB NUMBER: STAMPDRAWN BY:GAR02/13/2025WAKVD08500 1X2 (WAKVD05500 2X4)REVISIONSDATEDESCRIPTIONINITIALTEMPORARY TRAFFICCONTROL PLANTRAFFIC CONTROL PLAN-2128ADVANCED WARNING SIGN SPACINGROAD TYPESPEEDDISTANCE BETWEEN ADVANCEDWARNING SIGNSXXXXFREEWAYS & EXPRESSWAYS55/75 MPH1500 ±1500 ±1500 ±1500 ±RURAL HIGHWAYS60/65 MPH800 ±800 ±800 ±800 ±RURAL ROADS45/55 MPH500 ±500 ±500 ±500 ±RURAL ROADS & URBANARTERIAL35/40 MPH350 ±350 ±350 ±N/ARURAL ROADS, RESIDENTIAL &BUSINESS DISTRICTS25/30 MPH200 ± (2)200 ± (2)200 ± (2)N/AURBAN STREETS25 MPH ORLESS100 ± (2)100 ± (2)100 ± (2)N/A(1) ALL SPACING MAY BE ADJUSTED TO ACCOMMODATE INTERCHANGE RAMPS,AT-GRADE INTERSECTIONS, AND DRIVEWAYS.(2) THIS SPACING MAY BE REDUCED IN URBAN AREAS TO FIT ROADWAY CONDITIONS.LONGITUDINAL BUFFER SPACE =LBSSPEED (MPH)2025303540455055606570DISTANCE (FT)115155200250305360425495570645730TAPER LENGTH IN FEET=L (FEET)LANEWIDTH(FEET)POSTED SPEED LIMIT (MPH)2530354045505560657010105150205270450500550---11115160225295495550605660--1212518024532054060066072078084021WARNING SIGNREGULATORY SIGNTRAFFIC CONEFLAGGER STATIONPATROL CARPOLICEOFFICERPOLICE OFFICERWORK VEHICLELIT INTERSECTIONUNLIT INTERSECTIONSPOTTER STATIONKEEPRIGHT TCP DEVICE LEGENDFASFLASHING ARROWFLASHING DOUBLE ARROW(MERGE LEFT OR RIGHT)FLASHING CAUTIONFASFASFASTRAFFIC CONTROL PLAN GENERAL NOTES1.AN ARROWBOARD SHALL MEET THE MINIMUM SIZE,LEGIBILITY DISTANCE, NUMBER OF ELEMENTS ANDOTHER SPECIFICATIONS SHOWN.2.LENGTH OF ARROW EQUALS 48", WIDTH OFARROWHEAD EQUALS 24".3.TYPE A, B AND C ARROW BOARDS SHALL HAVESOLID RECTANGULAR APPEARANCES. A TYPE DARROW BOARD SHALL CONFORM TO THE SHAPE OFTHE ARROW.4.MAINTAIN DRIVEWAY ACCESS AT ALL TIMES5.SIDEWALK ARE EITHER OPEN OR NOT OPEN. ASIDEWALK IS CLOSED IF A MINIMUM 5' PATH CANNOTBE MAINTAINED MEASURED FROM PROPERTY LINE,OR 5.5' IF CREATED FROM FACE OF CURB.(PEDESTRIAN PATH PROVIDED WHERE REQUIRED)AND WILL BE MONITORED BY A SPOTTER TOENSURE FLOW AND SAFETY DURING WORK UNLESSOTHERWISE NOTED. A SPOTTER SHALL NOT DIRECTTRAFFIC.6.NO EXCEPTION TAKEN- CONTRACTOR ISRESPONSIBLE FOR ADA COMPLIANCE.7.ALL CONTROL SET-UP, SIGN SPACING ANDPROCEDURES. WILL CONFORM TO SPECIFICATIONSSTATED IN THE FEDERAL MANUAL ON UNIFORMEDTRAFFIC CONTROL DEVICES (M.U.T.C.D).8.CITIES AND VARIOUS MUNICIPALITIES MAY HAVEALSO ADOPTED SPECIALIZED GUIDELINES FORTRAFFIC CONTROL WITHIN THEIR JURISDICTION. ITIS THE RESPONSIBILITY OF THE ON-SITE TRAFFICCONTROL PERSONAL TO SEE IF AND ANY SPECIALCONDITIONS EXIST.9.FLAGGERS SHALL BE USED IN ACCORDANCE WITHWAC 468-95-302.10.IF ONLY ONE LANE IS OPEN IN A DIRECTION,THATLANE SHALL BE A MINIMUM OF 11' WIDE, UNLESSSPOTTER/FLAGGERS ARE USED, IN WHICH CASETHE LANE CAN BE A MINIMUM OF 10'.11.ALL ROW WORK MUST YIELD TO SCHOOL TRANSIT,EMPLOYEES AND CHILDREN. WHILE PASSENGERLOADING/UNLOADING, STOPPED OR SLOWING:CEASE WORK, YIELD. WHEN SCHOOL TRANSIT,AND/OR PEDESTRIANS, DEPART COMMENCE WORK.NXXXROAD WORK AHEAD SHOUL D E R WORK RIGHTSHOUL D E R CLOSED XXXROADWORKAHEADBEPREPAREDTO STOPFLAGGERXXXROADWORKAHEADBEPREPAREDTO STOPLIMITSPEEDR2-125FLAGGERSPOTT E R SPOTTERTALBOT RD SLIMIT SPEED R2-1 35LIMITSPEEDR2-13511'XXBEPREPA R E D TO ST O P FLAG G E RNOTE:AERIAL CROSSING TIME WILL BEAPPROXIMATE 5 MIN.MFP25001055 AAAAAAAAAAAAAAAAAAAAAAAAAAAAPFLFLFLFLFLFLFLFLFLFLFLFOCFOCFOCFOCFOCF O C R/WR/W R/W R/W R/WR/W R/W R/WR/WR/WFLFLFLFLFLFLFLEOPEOPEOPEOPEOPEOPR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/W204'215'S 196 PLFOCFOC FOC FOCFOCFOCFOCEOPFOCFOCFOC233'239'SWSWSWSWSWSW SW SWSWSWSWSWSWSWSWSWSWSWPOLE 10POLE 11POLE 12RDIGALERTFDX - WAKVD08600 1X2 - 19167 110TH PL SE RENTON, WA 98055, USA JB0002058033REVISIONSDATEDESCRIPTIONINITIAL COMCASTSHEETOFDATE:EXCEPT AS MAY BE OTHERWISE PROVIDED BY CONTRACT,THESE DRAWINGS AND SPECIFICATIONS SHALL REMAIN THEPROPERTY OF SEFNCO COMMUNICATION, INC. BOTH BEINGISSUED IN STRICT CONFIDENCE AND SHALL NOT BEREPRODUCED, COPIED, OR USED FOR ANY PURPOSEWITHOUT SPECIFIC WRITTEN PERMISSION.SITE NAME:SCALELOCATION ADDRESS: COMCAST JOB NUMBER: STAMPDRAWN BY:GAR02/13/2025WAKVD08500 1X2 (WAKVD05500 2X4)REVISIONSDATEDESCRIPTIONINITIALTEMPORARY TRAFFICCONTROL PLANTRAFFIC CONTROL PLAN-2228ADVANCED WARNING SIGN SPACINGROAD TYPESPEEDDISTANCE BETWEEN ADVANCEDWARNING SIGNSXXXXFREEWAYS & EXPRESSWAYS55/75 MPH1500 ±1500 ±1500 ±1500 ±RURAL HIGHWAYS60/65 MPH800 ±800 ±800 ±800 ±RURAL ROADS45/55 MPH500 ±500 ±500 ±500 ±RURAL ROADS & URBANARTERIAL35/40 MPH350 ±350 ±350 ±N/ARURAL ROADS, RESIDENTIAL &BUSINESS DISTRICTS25/30 MPH200 ± (2)200 ± (2)200 ± (2)N/AURBAN STREETS25 MPH ORLESS100 ± (2)100 ± (2)100 ± (2)N/A(1) ALL SPACING MAY BE ADJUSTED TO ACCOMMODATE INTERCHANGE RAMPS,AT-GRADE INTERSECTIONS, AND DRIVEWAYS.(2) THIS SPACING MAY BE REDUCED IN URBAN AREAS TO FIT ROADWAY CONDITIONS.LONGITUDINAL BUFFER SPACE =LBSSPEED (MPH)2025303540455055606570DISTANCE (FT)115155200250305360425495570645730TAPER LENGTH IN FEET=L (FEET)LANEWIDTH(FEET)POSTED SPEED LIMIT (MPH)2530354045505560657010105150205270450500550---11115160225295495550605660--1212518024532054060066072078084022WARNING SIGNREGULATORY SIGNTRAFFIC CONEFLAGGER STATIONPATROL CARPOLICEOFFICERPOLICE OFFICERWORK VEHICLELIT INTERSECTIONUNLIT INTERSECTIONSPOTTER STATIONKEEPRIGHT TCP DEVICE LEGENDFASFLASHING ARROWFLASHING DOUBLE ARROW(MERGE LEFT OR RIGHT)FLASHING CAUTIONFASFASFASTRAFFIC CONTROL PLAN GENERAL NOTES1.AN ARROWBOARD SHALL MEET THE MINIMUM SIZE,LEGIBILITY DISTANCE, NUMBER OF ELEMENTS ANDOTHER SPECIFICATIONS SHOWN.2.LENGTH OF ARROW EQUALS 48", WIDTH OFARROWHEAD EQUALS 24".3.TYPE A, B AND C ARROW BOARDS SHALL HAVESOLID RECTANGULAR APPEARANCES. A TYPE DARROW BOARD SHALL CONFORM TO THE SHAPE OFTHE ARROW.4.MAINTAIN DRIVEWAY ACCESS AT ALL TIMES5.SIDEWALK ARE EITHER OPEN OR NOT OPEN. ASIDEWALK IS CLOSED IF A MINIMUM 5' PATH CANNOTBE MAINTAINED MEASURED FROM PROPERTY LINE,OR 5.5' IF CREATED FROM FACE OF CURB.(PEDESTRIAN PATH PROVIDED WHERE REQUIRED)AND WILL BE MONITORED BY A SPOTTER TOENSURE FLOW AND SAFETY DURING WORK UNLESSOTHERWISE NOTED. A SPOTTER SHALL NOT DIRECTTRAFFIC.6.NO EXCEPTION TAKEN- CONTRACTOR ISRESPONSIBLE FOR ADA COMPLIANCE.7.ALL CONTROL SET-UP, SIGN SPACING ANDPROCEDURES. WILL CONFORM TO SPECIFICATIONSSTATED IN THE FEDERAL MANUAL ON UNIFORMEDTRAFFIC CONTROL DEVICES (M.U.T.C.D).8.CITIES AND VARIOUS MUNICIPALITIES MAY HAVEALSO ADOPTED SPECIALIZED GUIDELINES FORTRAFFIC CONTROL WITHIN THEIR JURISDICTION. ITIS THE RESPONSIBILITY OF THE ON-SITE TRAFFICCONTROL PERSONAL TO SEE IF AND ANY SPECIALCONDITIONS EXIST.9.FLAGGERS SHALL BE USED IN ACCORDANCE WITHWAC 468-95-302.10.IF ONLY ONE LANE IS OPEN IN A DIRECTION,THATLANE SHALL BE A MINIMUM OF 11' WIDE, UNLESSSPOTTER/FLAGGERS ARE USED, IN WHICH CASETHE LANE CAN BE A MINIMUM OF 10'.11.ALL ROW WORK MUST YIELD TO SCHOOL TRANSIT,EMPLOYEES AND CHILDREN. WHILE PASSENGERLOADING/UNLOADING, STOPPED OR SLOWING:CEASE WORK, YIELD. WHEN SCHOOL TRANSIT,AND/OR PEDESTRIANS, DEPART COMMENCE WORK.NXXXROADWORKAHEADBEPREPAREDTO STOPLIMITSPEEDR2-135FLAGGERXXXROADWORKAHEADBEPREPAREDTO STOPLIMITSPEEDR2-125FLAGGERSPOT T E R SPOTTER94979491948519640TALBOT RD S196521964619643TALBOT RD SNOTE:AERIAL CROSSING TIME WILL BEAPPROXIMATE 5 MIN.XXXROAD WORK AHEAD SHOUL D E R WORK RIGHTSHOUL D E R CLOSED LIMIT SPEED R2-1 35XXBEPREPA R E D TO STO P FLAG G E R 11'MFP25001055 PR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/ W R/WFOCFOCF O C F O CFOCS 196 PLS 196 PLSWSW SWRDIGALERTFDX - WAKVD08600 1X2 - 19167 110TH PL SE RENTON, WA 98055, USA JB0002058033REVISIONSDATEDESCRIPTIONINITIAL COMCASTSHEETOFDATE:EXCEPT AS MAY BE OTHERWISE PROVIDED BY CONTRACT,THESE DRAWINGS AND SPECIFICATIONS SHALL REMAIN THEPROPERTY OF SEFNCO COMMUNICATION, INC. BOTH BEINGISSUED IN STRICT CONFIDENCE AND SHALL NOT BEREPRODUCED, COPIED, OR USED FOR ANY PURPOSEWITHOUT SPECIFIC WRITTEN PERMISSION.SITE NAME:SCALELOCATION ADDRESS: COMCAST JOB NUMBER: STAMPDRAWN BY:GAR02/13/2025WAKVD08500 1X2 (WAKVD05500 2X4)REVISIONSDATEDESCRIPTIONINITIALTEMPORARY TRAFFICCONTROL PLANTRAFFIC CONTROL PLAN-2328ADVANCED WARNING SIGN SPACINGROAD TYPESPEEDDISTANCE BETWEEN ADVANCEDWARNING SIGNSXXXXFREEWAYS & EXPRESSWAYS55/75 MPH1500 ±1500 ±1500 ±1500 ±RURAL HIGHWAYS60/65 MPH800 ±800 ±800 ±800 ±RURAL ROADS45/55 MPH500 ±500 ±500 ±500 ±RURAL ROADS & URBANARTERIAL35/40 MPH350 ±350 ±350 ±N/ARURAL ROADS, RESIDENTIAL &BUSINESS DISTRICTS25/30 MPH200 ± (2)200 ± (2)200 ± (2)N/AURBAN STREETS25 MPH ORLESS100 ± (2)100 ± (2)100 ± (2)N/A(1) ALL SPACING MAY BE ADJUSTED TO ACCOMMODATE INTERCHANGE RAMPS,AT-GRADE INTERSECTIONS, AND DRIVEWAYS.(2) THIS SPACING MAY BE REDUCED IN URBAN AREAS TO FIT ROADWAY CONDITIONS.LONGITUDINAL BUFFER SPACE =LBSSPEED (MPH)2025303540455055606570DISTANCE (FT)115155200250305360425495570645730TAPER LENGTH IN FEET=L (FEET)LANEWIDTH(FEET)POSTED SPEED LIMIT (MPH)2530354045505560657010105150205270450500550---11115160225295495550605660--1212518024532054060066072078084023WARNING SIGNREGULATORY SIGNTRAFFIC CONEFLAGGER STATIONPATROL CARPOLICEOFFICERPOLICE OFFICERWORK VEHICLELIT INTERSECTIONUNLIT INTERSECTIONSPOTTER STATIONKEEPRIGHT TCP DEVICE LEGENDFASFLASHING ARROWFLASHING DOUBLE ARROW(MERGE LEFT OR RIGHT)FLASHING CAUTIONFASFASFASTRAFFIC CONTROL PLAN GENERAL NOTES1.AN ARROWBOARD SHALL MEET THE MINIMUM SIZE,LEGIBILITY DISTANCE, NUMBER OF ELEMENTS ANDOTHER SPECIFICATIONS SHOWN.2.LENGTH OF ARROW EQUALS 48", WIDTH OFARROWHEAD EQUALS 24".3.TYPE A, B AND C ARROW BOARDS SHALL HAVESOLID RECTANGULAR APPEARANCES. A TYPE DARROW BOARD SHALL CONFORM TO THE SHAPE OFTHE ARROW.4.MAINTAIN DRIVEWAY ACCESS AT ALL TIMES5.SIDEWALK ARE EITHER OPEN OR NOT OPEN. ASIDEWALK IS CLOSED IF A MINIMUM 5' PATH CANNOTBE MAINTAINED MEASURED FROM PROPERTY LINE,OR 5.5' IF CREATED FROM FACE OF CURB.(PEDESTRIAN PATH PROVIDED WHERE REQUIRED)AND WILL BE MONITORED BY A SPOTTER TOENSURE FLOW AND SAFETY DURING WORK UNLESSOTHERWISE NOTED. A SPOTTER SHALL NOT DIRECTTRAFFIC.6.NO EXCEPTION TAKEN- CONTRACTOR ISRESPONSIBLE FOR ADA COMPLIANCE.7.ALL CONTROL SET-UP, SIGN SPACING ANDPROCEDURES. WILL CONFORM TO SPECIFICATIONSSTATED IN THE FEDERAL MANUAL ON UNIFORMEDTRAFFIC CONTROL DEVICES (M.U.T.C.D).8.CITIES AND VARIOUS MUNICIPALITIES MAY HAVEALSO ADOPTED SPECIALIZED GUIDELINES FORTRAFFIC CONTROL WITHIN THEIR JURISDICTION. ITIS THE RESPONSIBILITY OF THE ON-SITE TRAFFICCONTROL PERSONAL TO SEE IF AND ANY SPECIALCONDITIONS EXIST.9.FLAGGERS SHALL BE USED IN ACCORDANCE WITHWAC 468-95-302.10.IF ONLY ONE LANE IS OPEN IN A DIRECTION,THATLANE SHALL BE A MINIMUM OF 11' WIDE, UNLESSSPOTTER/FLAGGERS ARE USED, IN WHICH CASETHE LANE CAN BE A MINIMUM OF 10'.11.ALL ROW WORK MUST YIELD TO SCHOOL TRANSIT,EMPLOYEES AND CHILDREN. WHILE PASSENGERLOADING/UNLOADING, STOPPED OR SLOWING:CEASE WORK, YIELD. WHEN SCHOOL TRANSIT,AND/OR PEDESTRIANS, DEPART COMMENCE WORK.NNOTE:ADJACENT BUSINESSES AND/OR RESIDENT'SWILL BE NOTIFIED IN WRITING 72 HOURS PRIORTO PLACEMENT OF "NO PARKING" SIGNS.20'XXXROADWORKAHEADSHOULDERWORKRIGHTSHOULDERCLOSEDXR O A DWOR KAHE A DTOW-AWAY AREA RCW 46 55 113TOW-AWAY AREA RCW 46 55 113 NOTE:ADJACENT BUSINESSES AND/OR RESIDENT'SWILL BE NOTIFIED IN WRITING 72 HOURS PRIORTO PLACEMENT OF "NO PARKING" SIGNS.SPOTTER SPOTTERTOW-AWAY AREA RCW 46 55 1 13 TOW-AWAY AREA RCW 46 55 113LIMITSPEEDR2-125LIM I T S P E ED R 2 - 1 2 5 MFP25001055 AAAAAAAAAAAAAAAAAAAAAAPFLFLFOCFOCFOCFOCR/WR/WR/WFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLEOPFLFLFLFLR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WEOPEOPEOPEOPFOCEOPFOCFOCFOC233'239'SWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWPOLE 11POLE 13POLE 121980119809TALBOT RD STALBOT RD S1970619808RDIGALERTFDX - WAKVD08600 1X2 - 19167 110TH PL SE RENTON, WA 98055, USA JB0002058033REVISIONSDATEDESCRIPTIONINITIAL COMCASTSHEETOFDATE:EXCEPT AS MAY BE OTHERWISE PROVIDED BY CONTRACT,THESE DRAWINGS AND SPECIFICATIONS SHALL REMAIN THEPROPERTY OF SEFNCO COMMUNICATION, INC. BOTH BEINGISSUED IN STRICT CONFIDENCE AND SHALL NOT BEREPRODUCED, COPIED, OR USED FOR ANY PURPOSEWITHOUT SPECIFIC WRITTEN PERMISSION.SITE NAME:SCALELOCATION ADDRESS: COMCAST JOB NUMBER: STAMPDRAWN BY:GAR02/13/2025WAKVD08500 1X2 (WAKVD05500 2X4)REVISIONSDATEDESCRIPTIONINITIALTEMPORARY TRAFFICCONTROL PLANTRAFFIC CONTROL PLAN-2428ADVANCED WARNING SIGN SPACINGROAD TYPESPEEDDISTANCE BETWEEN ADVANCEDWARNING SIGNSXXXXFREEWAYS & EXPRESSWAYS55/75 MPH1500 ±1500 ±1500 ±1500 ±RURAL HIGHWAYS60/65 MPH800 ±800 ±800 ±800 ±RURAL ROADS45/55 MPH500 ±500 ±500 ±500 ±RURAL ROADS & URBANARTERIAL35/40 MPH350 ±350 ±350 ±N/ARURAL ROADS, RESIDENTIAL &BUSINESS DISTRICTS25/30 MPH200 ± (2)200 ± (2)200 ± (2)N/AURBAN STREETS25 MPH ORLESS100 ± (2)100 ± (2)100 ± (2)N/A(1) ALL SPACING MAY BE ADJUSTED TO ACCOMMODATE INTERCHANGE RAMPS,AT-GRADE INTERSECTIONS, AND DRIVEWAYS.(2) THIS SPACING MAY BE REDUCED IN URBAN AREAS TO FIT ROADWAY CONDITIONS.LONGITUDINAL BUFFER SPACE =LBSSPEED (MPH)2025303540455055606570DISTANCE (FT)115155200250305360425495570645730TAPER LENGTH IN FEET=L (FEET)LANEWIDTH(FEET)POSTED SPEED LIMIT (MPH)2530354045505560657010105150205270450500550---11115160225295495550605660--1212518024532054060066072078084024WARNING SIGNREGULATORY SIGNTRAFFIC CONEFLAGGER STATIONPATROL CARPOLICEOFFICERPOLICE OFFICERWORK VEHICLELIT INTERSECTIONUNLIT INTERSECTIONSPOTTER STATIONKEEPRIGHT TCP DEVICE LEGENDFASFLASHING ARROWFLASHING DOUBLE ARROW(MERGE LEFT OR RIGHT)FLASHING CAUTIONFASFASFASTRAFFIC CONTROL PLAN GENERAL NOTES1.AN ARROWBOARD SHALL MEET THE MINIMUM SIZE,LEGIBILITY DISTANCE, NUMBER OF ELEMENTS ANDOTHER SPECIFICATIONS SHOWN.2.LENGTH OF ARROW EQUALS 48", WIDTH OFARROWHEAD EQUALS 24".3.TYPE A, B AND C ARROW BOARDS SHALL HAVESOLID RECTANGULAR APPEARANCES. A TYPE DARROW BOARD SHALL CONFORM TO THE SHAPE OFTHE ARROW.4.MAINTAIN DRIVEWAY ACCESS AT ALL TIMES5.SIDEWALK ARE EITHER OPEN OR NOT OPEN. ASIDEWALK IS CLOSED IF A MINIMUM 5' PATH CANNOTBE MAINTAINED MEASURED FROM PROPERTY LINE,OR 5.5' IF CREATED FROM FACE OF CURB.(PEDESTRIAN PATH PROVIDED WHERE REQUIRED)AND WILL BE MONITORED BY A SPOTTER TOENSURE FLOW AND SAFETY DURING WORK UNLESSOTHERWISE NOTED. A SPOTTER SHALL NOT DIRECTTRAFFIC.6.NO EXCEPTION TAKEN- CONTRACTOR ISRESPONSIBLE FOR ADA COMPLIANCE.7.ALL CONTROL SET-UP, SIGN SPACING ANDPROCEDURES. WILL CONFORM TO SPECIFICATIONSSTATED IN THE FEDERAL MANUAL ON UNIFORMEDTRAFFIC CONTROL DEVICES (M.U.T.C.D).8.CITIES AND VARIOUS MUNICIPALITIES MAY HAVEALSO ADOPTED SPECIALIZED GUIDELINES FORTRAFFIC CONTROL WITHIN THEIR JURISDICTION. ITIS THE RESPONSIBILITY OF THE ON-SITE TRAFFICCONTROL PERSONAL TO SEE IF AND ANY SPECIALCONDITIONS EXIST.9.FLAGGERS SHALL BE USED IN ACCORDANCE WITHWAC 468-95-302.10.IF ONLY ONE LANE IS OPEN IN A DIRECTION,THATLANE SHALL BE A MINIMUM OF 11' WIDE, UNLESSSPOTTER/FLAGGERS ARE USED, IN WHICH CASETHE LANE CAN BE A MINIMUM OF 10'.11.ALL ROW WORK MUST YIELD TO SCHOOL TRANSIT,EMPLOYEES AND CHILDREN. WHILE PASSENGERLOADING/UNLOADING, STOPPED OR SLOWING:CEASE WORK, YIELD. WHEN SCHOOL TRANSIT,AND/OR PEDESTRIANS, DEPART COMMENCE WORK.NXXXROAD WORK AHEAD ONELANEROADAHEAD FLAG G E R XXXROADWORKAHEADONELANEROADAHEADFLAGGERSPOT T E R SPOTTER1964319653196461970019652LIMIT SPEED R2-1 35LIMITSPEEDR2-135MFP25001055 R/W R/W R/WR/W R/WR/WR/WAAAAAAAAAAAPFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLEOPEOPEOPR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WFLFLFLEOPEOP EOP EOPEOPEOPEOPFOCEOPFOCFOC239'SWSWSWSWSWSWSWSWSWSWPOLEPOLE 139522TALBOT RD STALBOT RD SS 199TH ST 9513RDIGALERTFDX - WAKVD08600 1X2 - 19167 110TH PL SE RENTON, WA 98055, USA JB0002058033REVISIONSDATEDESCRIPTIONINITIAL COMCASTSHEETOFDATE:EXCEPT AS MAY BE OTHERWISE PROVIDED BY CONTRACT,THESE DRAWINGS AND SPECIFICATIONS SHALL REMAIN THEPROPERTY OF SEFNCO COMMUNICATION, INC. BOTH BEINGISSUED IN STRICT CONFIDENCE AND SHALL NOT BEREPRODUCED, COPIED, OR USED FOR ANY PURPOSEWITHOUT SPECIFIC WRITTEN PERMISSION.SITE NAME:SCALELOCATION ADDRESS: COMCAST JOB NUMBER: STAMPDRAWN BY:GAR02/13/2025WAKVD08500 1X2 (WAKVD05500 2X4)REVISIONSDATEDESCRIPTIONINITIALTEMPORARY TRAFFICCONTROL PLANTRAFFIC CONTROL PLAN-2528ADVANCED WARNING SIGN SPACINGROAD TYPESPEEDDISTANCE BETWEEN ADVANCEDWARNING SIGNSXXXXFREEWAYS & EXPRESSWAYS55/75 MPH1500 ±1500 ±1500 ±1500 ±RURAL HIGHWAYS60/65 MPH800 ±800 ±800 ±800 ±RURAL ROADS45/55 MPH500 ±500 ±500 ±500 ±RURAL ROADS & URBANARTERIAL35/40 MPH350 ±350 ±350 ±N/ARURAL ROADS, RESIDENTIAL &BUSINESS DISTRICTS25/30 MPH200 ± (2)200 ± (2)200 ± (2)N/AURBAN STREETS25 MPH ORLESS100 ± (2)100 ± (2)100 ± (2)N/A(1) ALL SPACING MAY BE ADJUSTED TO ACCOMMODATE INTERCHANGE RAMPS,AT-GRADE INTERSECTIONS, AND DRIVEWAYS.(2) THIS SPACING MAY BE REDUCED IN URBAN AREAS TO FIT ROADWAY CONDITIONS.LONGITUDINAL BUFFER SPACE =LBSSPEED (MPH)2025303540455055606570DISTANCE (FT)115155200250305360425495570645730TAPER LENGTH IN FEET=L (FEET)LANEWIDTH(FEET)POSTED SPEED LIMIT (MPH)2530354045505560657010105150205270450500550---11115160225295495550605660--1212518024532054060066072078084025WARNING SIGNREGULATORY SIGNTRAFFIC CONEFLAGGER STATIONPATROL CARPOLICEOFFICERPOLICE OFFICERWORK VEHICLELIT INTERSECTIONUNLIT INTERSECTIONSPOTTER STATIONKEEPRIGHT TCP DEVICE LEGENDFASFLASHING ARROWFLASHING DOUBLE ARROW(MERGE LEFT OR RIGHT)FLASHING CAUTIONFASFASFASTRAFFIC CONTROL PLAN GENERAL NOTES1.AN ARROWBOARD SHALL MEET THE MINIMUM SIZE,LEGIBILITY DISTANCE, NUMBER OF ELEMENTS ANDOTHER SPECIFICATIONS SHOWN.2.LENGTH OF ARROW EQUALS 48", WIDTH OFARROWHEAD EQUALS 24".3.TYPE A, B AND C ARROW BOARDS SHALL HAVESOLID RECTANGULAR APPEARANCES. A TYPE DARROW BOARD SHALL CONFORM TO THE SHAPE OFTHE ARROW.4.MAINTAIN DRIVEWAY ACCESS AT ALL TIMES5.SIDEWALK ARE EITHER OPEN OR NOT OPEN. ASIDEWALK IS CLOSED IF A MINIMUM 5' PATH CANNOTBE MAINTAINED MEASURED FROM PROPERTY LINE,OR 5.5' IF CREATED FROM FACE OF CURB.(PEDESTRIAN PATH PROVIDED WHERE REQUIRED)AND WILL BE MONITORED BY A SPOTTER TOENSURE FLOW AND SAFETY DURING WORK UNLESSOTHERWISE NOTED. A SPOTTER SHALL NOT DIRECTTRAFFIC.6.NO EXCEPTION TAKEN- CONTRACTOR ISRESPONSIBLE FOR ADA COMPLIANCE.7.ALL CONTROL SET-UP, SIGN SPACING ANDPROCEDURES. WILL CONFORM TO SPECIFICATIONSSTATED IN THE FEDERAL MANUAL ON UNIFORMEDTRAFFIC CONTROL DEVICES (M.U.T.C.D).8.CITIES AND VARIOUS MUNICIPALITIES MAY HAVEALSO ADOPTED SPECIALIZED GUIDELINES FORTRAFFIC CONTROL WITHIN THEIR JURISDICTION. ITIS THE RESPONSIBILITY OF THE ON-SITE TRAFFICCONTROL PERSONAL TO SEE IF AND ANY SPECIALCONDITIONS EXIST.9.FLAGGERS SHALL BE USED IN ACCORDANCE WITHWAC 468-95-302.10.IF ONLY ONE LANE IS OPEN IN A DIRECTION,THATLANE SHALL BE A MINIMUM OF 11' WIDE, UNLESSSPOTTER/FLAGGERS ARE USED, IN WHICH CASETHE LANE CAN BE A MINIMUM OF 10'.11.ALL ROW WORK MUST YIELD TO SCHOOL TRANSIT,EMPLOYEES AND CHILDREN. WHILE PASSENGERLOADING/UNLOADING, STOPPED OR SLOWING:CEASE WORK, YIELD. WHEN SCHOOL TRANSIT,AND/OR PEDESTRIANS, DEPART COMMENCE WORK.NXXXROAD WORK AHEAD ONELANEROADAHEAD FLAG G E R XXXROADWORKAHEADONELANEROADAHEADFLAGGERSPOT T E R19808 198011980919653TALBOT RD SLIMIT SPEED R2-1 35LIMITSPEEDR2-135MFP25001055 R/WR/WR/WR/WR/W R/W R/WR/WR/WR/WR/W FLFLFLFLFLFLFLFLFLFLFLFLFLFLEOP EOP R/W R/W R/W R/W R/W R/W R/W R/W R/WR/WR/WR/WR/WR/WFLEOPEOPEOP952219809TALBO T R D S TALBO T R D S S 199TH ST198081981695139507EOPEOP EOPEOPPOLE POLE 1 3 RDIGALERTFDX - WAKVD08600 1X2 - 19167 110TH PL SE RENTON, WA 98055, USA JB0002058033REVISIONSDATEDESCRIPTIONINITIAL COMCASTSHEETOFDATE:EXCEPT AS MAY BE OTHERWISE PROVIDED BY CONTRACT,THESE DRAWINGS AND SPECIFICATIONS SHALL REMAIN THEPROPERTY OF SEFNCO COMMUNICATION, INC. BOTH BEINGISSUED IN STRICT CONFIDENCE AND SHALL NOT BEREPRODUCED, COPIED, OR USED FOR ANY PURPOSEWITHOUT SPECIFIC WRITTEN PERMISSION.SITE NAME:SCALELOCATION ADDRESS: COMCAST JOB NUMBER: STAMPDRAWN BY:GAR02/13/2025WAKVD08500 1X2 (WAKVD05500 2X4)REVISIONSDATEDESCRIPTIONINITIALTEMPORARY TRAFFICCONTROL PLANTRAFFIC CONTROL PLAN-2628ADVANCED WARNING SIGN SPACINGROAD TYPESPEEDDISTANCE BETWEEN ADVANCEDWARNING SIGNSXXXXFREEWAYS & EXPRESSWAYS55/75 MPH1500 ±1500 ±1500 ±1500 ±RURAL HIGHWAYS60/65 MPH800 ±800 ±800 ±800 ±RURAL ROADS45/55 MPH500 ±500 ±500 ±500 ±RURAL ROADS & URBANARTERIAL35/40 MPH350 ±350 ±350 ±N/ARURAL ROADS, RESIDENTIAL &BUSINESS DISTRICTS25/30 MPH200 ± (2)200 ± (2)200 ± (2)N/AURBAN STREETS25 MPH ORLESS100 ± (2)100 ± (2)100 ± (2)N/A(1) ALL SPACING MAY BE ADJUSTED TO ACCOMMODATE INTERCHANGE RAMPS,AT-GRADE INTERSECTIONS, AND DRIVEWAYS.(2) THIS SPACING MAY BE REDUCED IN URBAN AREAS TO FIT ROADWAY CONDITIONS.LONGITUDINAL BUFFER SPACE =LBSSPEED (MPH)2025303540455055606570DISTANCE (FT)115155200250305360425495570645730TAPER LENGTH IN FEET=L (FEET)LANEWIDTH(FEET)POSTED SPEED LIMIT (MPH)2530354045505560657010105150205270450500550---11115160225295495550605660--1212518024532054060066072078084026WARNING SIGNREGULATORY SIGNTRAFFIC CONEFLAGGER STATIONPATROL CARPOLICEOFFICERPOLICE OFFICERWORK VEHICLELIT INTERSECTIONUNLIT INTERSECTIONSPOTTER STATIONKEEPRIGHT TCP DEVICE LEGENDFASFLASHING ARROWFLASHING DOUBLE ARROW(MERGE LEFT OR RIGHT)FLASHING CAUTIONFASFASFASTRAFFIC CONTROL PLAN GENERAL NOTES1.AN ARROWBOARD SHALL MEET THE MINIMUM SIZE,LEGIBILITY DISTANCE, NUMBER OF ELEMENTS ANDOTHER SPECIFICATIONS SHOWN.2.LENGTH OF ARROW EQUALS 48", WIDTH OFARROWHEAD EQUALS 24".3.TYPE A, B AND C ARROW BOARDS SHALL HAVESOLID RECTANGULAR APPEARANCES. A TYPE DARROW BOARD SHALL CONFORM TO THE SHAPE OFTHE ARROW.4.MAINTAIN DRIVEWAY ACCESS AT ALL TIMES5.SIDEWALK ARE EITHER OPEN OR NOT OPEN. ASIDEWALK IS CLOSED IF A MINIMUM 5' PATH CANNOTBE MAINTAINED MEASURED FROM PROPERTY LINE,OR 5.5' IF CREATED FROM FACE OF CURB.(PEDESTRIAN PATH PROVIDED WHERE REQUIRED)AND WILL BE MONITORED BY A SPOTTER TOENSURE FLOW AND SAFETY DURING WORK UNLESSOTHERWISE NOTED. A SPOTTER SHALL NOT DIRECTTRAFFIC.6.NO EXCEPTION TAKEN- CONTRACTOR ISRESPONSIBLE FOR ADA COMPLIANCE.7.ALL CONTROL SET-UP, SIGN SPACING ANDPROCEDURES. WILL CONFORM TO SPECIFICATIONSSTATED IN THE FEDERAL MANUAL ON UNIFORMEDTRAFFIC CONTROL DEVICES (M.U.T.C.D).8.CITIES AND VARIOUS MUNICIPALITIES MAY HAVEALSO ADOPTED SPECIALIZED GUIDELINES FORTRAFFIC CONTROL WITHIN THEIR JURISDICTION. ITIS THE RESPONSIBILITY OF THE ON-SITE TRAFFICCONTROL PERSONAL TO SEE IF AND ANY SPECIALCONDITIONS EXIST.9.FLAGGERS SHALL BE USED IN ACCORDANCE WITHWAC 468-95-302.10.IF ONLY ONE LANE IS OPEN IN A DIRECTION,THATLANE SHALL BE A MINIMUM OF 11' WIDE, UNLESSSPOTTER/FLAGGERS ARE USED, IN WHICH CASETHE LANE CAN BE A MINIMUM OF 10'.11.ALL ROW WORK MUST YIELD TO SCHOOL TRANSIT,EMPLOYEES AND CHILDREN. WHILE PASSENGERLOADING/UNLOADING, STOPPED OR SLOWING:CEASE WORK, YIELD. WHEN SCHOOL TRANSIT,AND/OR PEDESTRIANS, DEPART COMMENCE WORK.NX X X ROADWORKAHEADSHOULDERWORKRIGHTSHOULDERCLOSEDX ROADWORKAHEADXROADWORKAHEADLIMITSPEEDR2-125LIMITSPEEDR2-135LIMITSPEEDR2-135MFP25001055 R/W R/W R/W FOC EOPR/W R/W R/W R/W R/W R/W R/W R/W 92ND AVE S R/WR/WFOC92049713EOPFOC FOC FOC FOC FOCFOCPOLE RDIGALERTFDX - WAKVD08600 1X2 - 19167 110TH PL SE RENTON, WA 98055, USA JB0002058033REVISIONSDATEDESCRIPTIONINITIAL COMCASTSHEETOFDATE:EXCEPT AS MAY BE OTHERWISE PROVIDED BY CONTRACT,THESE DRAWINGS AND SPECIFICATIONS SHALL REMAIN THEPROPERTY OF SEFNCO COMMUNICATION, INC. BOTH BEINGISSUED IN STRICT CONFIDENCE AND SHALL NOT BEREPRODUCED, COPIED, OR USED FOR ANY PURPOSEWITHOUT SPECIFIC WRITTEN PERMISSION.SITE NAME:SCALELOCATION ADDRESS: COMCAST JOB NUMBER: STAMPDRAWN BY:GAR02/13/2025WAKVD08500 1X2 (WAKVD05500 2X4)REVISIONSDATEDESCRIPTIONINITIALTEMPORARY TRAFFICCONTROL PLANTRAFFIC CONTROL PLAN-2728ADVANCED WARNING SIGN SPACINGROAD TYPESPEEDDISTANCE BETWEEN ADVANCEDWARNING SIGNSXXXXFREEWAYS & EXPRESSWAYS55/75 MPH1500 ±1500 ±1500 ±1500 ±RURAL HIGHWAYS60/65 MPH800 ±800 ±800 ±800 ±RURAL ROADS45/55 MPH500 ±500 ±500 ±500 ±RURAL ROADS & URBANARTERIAL35/40 MPH350 ±350 ±350 ±N/ARURAL ROADS, RESIDENTIAL &BUSINESS DISTRICTS25/30 MPH200 ± (2)200 ± (2)200 ± (2)N/AURBAN STREETS25 MPH ORLESS100 ± (2)100 ± (2)100 ± (2)N/A(1) ALL SPACING MAY BE ADJUSTED TO ACCOMMODATE INTERCHANGE RAMPS,AT-GRADE INTERSECTIONS, AND DRIVEWAYS.(2) THIS SPACING MAY BE REDUCED IN URBAN AREAS TO FIT ROADWAY CONDITIONS.LONGITUDINAL BUFFER SPACE =LBSSPEED (MPH)2025303540455055606570DISTANCE (FT)115155200250305360425495570645730TAPER LENGTH IN FEET=L (FEET)LANEWIDTH(FEET)POSTED SPEED LIMIT (MPH)2530354045505560657010105150205270450500550---11115160225295495550605660--1212518024532054060066072078084027WARNING SIGNREGULATORY SIGNTRAFFIC CONEFLAGGER STATIONPATROL CARPOLICEOFFICERPOLICE OFFICERWORK VEHICLELIT INTERSECTIONUNLIT INTERSECTIONSPOTTER STATIONKEEPRIGHT TCP DEVICE LEGENDFASFLASHING ARROWFLASHING DOUBLE ARROW(MERGE LEFT OR RIGHT)FLASHING CAUTIONFASFASFASTRAFFIC CONTROL PLAN GENERAL NOTES1.AN ARROWBOARD SHALL MEET THE MINIMUM SIZE,LEGIBILITY DISTANCE, NUMBER OF ELEMENTS ANDOTHER SPECIFICATIONS SHOWN.2.LENGTH OF ARROW EQUALS 48", WIDTH OFARROWHEAD EQUALS 24".3.TYPE A, B AND C ARROW BOARDS SHALL HAVESOLID RECTANGULAR APPEARANCES. A TYPE DARROW BOARD SHALL CONFORM TO THE SHAPE OFTHE ARROW.4.MAINTAIN DRIVEWAY ACCESS AT ALL TIMES5.SIDEWALK ARE EITHER OPEN OR NOT OPEN. ASIDEWALK IS CLOSED IF A MINIMUM 5' PATH CANNOTBE MAINTAINED MEASURED FROM PROPERTY LINE,OR 5.5' IF CREATED FROM FACE OF CURB.(PEDESTRIAN PATH PROVIDED WHERE REQUIRED)AND WILL BE MONITORED BY A SPOTTER TOENSURE FLOW AND SAFETY DURING WORK UNLESSOTHERWISE NOTED. A SPOTTER SHALL NOT DIRECTTRAFFIC.6.NO EXCEPTION TAKEN- CONTRACTOR ISRESPONSIBLE FOR ADA COMPLIANCE.7.ALL CONTROL SET-UP, SIGN SPACING ANDPROCEDURES. WILL CONFORM TO SPECIFICATIONSSTATED IN THE FEDERAL MANUAL ON UNIFORMEDTRAFFIC CONTROL DEVICES (M.U.T.C.D).8.CITIES AND VARIOUS MUNICIPALITIES MAY HAVEALSO ADOPTED SPECIALIZED GUIDELINES FORTRAFFIC CONTROL WITHIN THEIR JURISDICTION. ITIS THE RESPONSIBILITY OF THE ON-SITE TRAFFICCONTROL PERSONAL TO SEE IF AND ANY SPECIALCONDITIONS EXIST.9.FLAGGERS SHALL BE USED IN ACCORDANCE WITHWAC 468-95-302.10.IF ONLY ONE LANE IS OPEN IN A DIRECTION,THATLANE SHALL BE A MINIMUM OF 11' WIDE, UNLESSSPOTTER/FLAGGERS ARE USED, IN WHICH CASETHE LANE CAN BE A MINIMUM OF 10'.11.ALL ROW WORK MUST YIELD TO SCHOOL TRANSIT,EMPLOYEES AND CHILDREN. WHILE PASSENGERLOADING/UNLOADING, STOPPED OR SLOWING:CEASE WORK, YIELD. WHEN SCHOOL TRANSIT,AND/OR PEDESTRIANS, DEPART COMMENCE WORK.NXXXROA D WO R K AHE A D ONELAN E ROA DAHE A D LIMI T SPEE D R2-1 25 FLA G G E R XXX ROADWORKAHEADONELANEROADAHEADLIMITSPEEDR2-125FLAGGERS 198TH STSPOTTER11'MFP25001055 R/W R/W R/WR/WR/WR/WR/WR/W R/WR/WR/W EOPEOPEOPEOPFOC FOC 97TH AVE SS 198TH PL (PRIVATE RD)97T H A V E S 199019615961619834FOC FOC FOC FOCFOCFOCFOC FOC FOCPOLERDIGALERTFDX - WAKVD08600 1X2 - 19167 110TH PL SE RENTON, WA 98055, USA JB0002058033REVISIONSDATEDESCRIPTIONINITIAL COMCASTSHEETOFDATE:EXCEPT AS MAY BE OTHERWISE PROVIDED BY CONTRACT,THESE DRAWINGS AND SPECIFICATIONS SHALL REMAIN THEPROPERTY OF SEFNCO COMMUNICATION, INC. BOTH BEINGISSUED IN STRICT CONFIDENCE AND SHALL NOT BEREPRODUCED, COPIED, OR USED FOR ANY PURPOSEWITHOUT SPECIFIC WRITTEN PERMISSION.SITE NAME:SCALELOCATION ADDRESS: COMCAST JOB NUMBER: STAMPDRAWN BY:GAR02/13/2025WAKVD08500 1X2 (WAKVD05500 2X4)REVISIONSDATEDESCRIPTIONINITIALTEMPORARY TRAFFICCONTROL PLANTRAFFIC CONTROL PLAN-2828ADVANCED WARNING SIGN SPACINGROAD TYPESPEEDDISTANCE BETWEEN ADVANCEDWARNING SIGNSXXXXFREEWAYS & EXPRESSWAYS55/75 MPH1500 ±1500 ±1500 ±1500 ±RURAL HIGHWAYS60/65 MPH800 ±800 ±800 ±800 ±RURAL ROADS45/55 MPH500 ±500 ±500 ±500 ±RURAL ROADS & URBANARTERIAL35/40 MPH350 ±350 ±350 ±N/ARURAL ROADS, RESIDENTIAL &BUSINESS DISTRICTS25/30 MPH200 ± (2)200 ± (2)200 ± (2)N/AURBAN STREETS25 MPH ORLESS100 ± (2)100 ± (2)100 ± (2)N/A(1) ALL SPACING MAY BE ADJUSTED TO ACCOMMODATE INTERCHANGE RAMPS,AT-GRADE INTERSECTIONS, AND DRIVEWAYS.(2) THIS SPACING MAY BE REDUCED IN URBAN AREAS TO FIT ROADWAY CONDITIONS.LONGITUDINAL BUFFER SPACE =LBSSPEED (MPH)2025303540455055606570DISTANCE (FT)115155200250305360425495570645730TAPER LENGTH IN FEET=L (FEET)LANEWIDTH(FEET)POSTED SPEED LIMIT (MPH)2530354045505560657010105150205270450500550---11115160225295495550605660--1212518024532054060066072078084028WARNING SIGNREGULATORY SIGNTRAFFIC CONEFLAGGER STATIONPATROL CARPOLICEOFFICERPOLICE OFFICERWORK VEHICLELIT INTERSECTIONUNLIT INTERSECTIONSPOTTER STATIONKEEPRIGHT TCP DEVICE LEGENDFASFLASHING ARROWFLASHING DOUBLE ARROW(MERGE LEFT OR RIGHT)FLASHING CAUTIONFASFASFASTRAFFIC CONTROL PLAN GENERAL NOTES1.AN ARROWBOARD SHALL MEET THE MINIMUM SIZE,LEGIBILITY DISTANCE, NUMBER OF ELEMENTS ANDOTHER SPECIFICATIONS SHOWN.2.LENGTH OF ARROW EQUALS 48", WIDTH OFARROWHEAD EQUALS 24".3.TYPE A, B AND C ARROW BOARDS SHALL HAVESOLID RECTANGULAR APPEARANCES. A TYPE DARROW BOARD SHALL CONFORM TO THE SHAPE OFTHE ARROW.4.MAINTAIN DRIVEWAY ACCESS AT ALL TIMES5.SIDEWALK ARE EITHER OPEN OR NOT OPEN. ASIDEWALK IS CLOSED IF A MINIMUM 5' PATH CANNOTBE MAINTAINED MEASURED FROM PROPERTY LINE,OR 5.5' IF CREATED FROM FACE OF CURB.(PEDESTRIAN PATH PROVIDED WHERE REQUIRED)AND WILL BE MONITORED BY A SPOTTER TOENSURE FLOW AND SAFETY DURING WORK UNLESSOTHERWISE NOTED. A SPOTTER SHALL NOT DIRECTTRAFFIC.6.NO EXCEPTION TAKEN- CONTRACTOR ISRESPONSIBLE FOR ADA COMPLIANCE.7.ALL CONTROL SET-UP, SIGN SPACING ANDPROCEDURES. WILL CONFORM TO SPECIFICATIONSSTATED IN THE FEDERAL MANUAL ON UNIFORMEDTRAFFIC CONTROL DEVICES (M.U.T.C.D).8.CITIES AND VARIOUS MUNICIPALITIES MAY HAVEALSO ADOPTED SPECIALIZED GUIDELINES FORTRAFFIC CONTROL WITHIN THEIR JURISDICTION. ITIS THE RESPONSIBILITY OF THE ON-SITE TRAFFICCONTROL PERSONAL TO SEE IF AND ANY SPECIALCONDITIONS EXIST.9.FLAGGERS SHALL BE USED IN ACCORDANCE WITHWAC 468-95-302.10.IF ONLY ONE LANE IS OPEN IN A DIRECTION,THATLANE SHALL BE A MINIMUM OF 11' WIDE, UNLESSSPOTTER/FLAGGERS ARE USED, IN WHICH CASETHE LANE CAN BE A MINIMUM OF 10'.11.ALL ROW WORK MUST YIELD TO SCHOOL TRANSIT,EMPLOYEES AND CHILDREN. WHILE PASSENGERLOADING/UNLOADING, STOPPED OR SLOWING:CEASE WORK, YIELD. WHEN SCHOOL TRANSIT,AND/OR PEDESTRIANS, DEPART COMMENCE WORK.NX X X ROADWORKAHEADSHOULDERWORKRIGHTSHOULDERCLOSEDLIMITSPEEDR2-125ROADWORKAHEADXROAD WORKAHEAD LIMIT SPEED R2-1 25SPOTTER MFP25001055 COMCASTFDX - WAKVD08600 1X2 - WAKVD08500 1X2 (WAKVD05500 2X4)19167 110TH PL SE, RENTON, WA 98055, USAJB0002058033EQUIPMENT REPLACEMENT AT AERIAL AND UG LOCATIONS &PROPOSED AERIAL FIBER INSTALLATIONMFP25001055This permit is for Major construction work in the ROW and will be billed at an additional$158/HR for inspections. After hours and weekend work will be billed at $175/HR RDIGALERTFDX - WAKVD08600 1X2 - 19167 110TH PL SE RENTON, WA 98055, USA JB0002058033REVISIONSDATEDESCRIPTIONINITIAL COMCASTSHEETOFDATE:EXCEPT AS MAY BE OTHERWISE PROVIDED BY CONTRACT,THESE DRAWINGS AND SPECIFICATIONS SHALL REMAIN THEPROPERTY OF SEFNCO COMMUNICATION, INC. BOTH BEINGISSUED IN STRICT CONFIDENCE AND SHALL NOT BEREPRODUCED, COPIED, OR USED FOR ANY PURPOSEWITHOUT SPECIFIC WRITTEN PERMISSION.SITE NAME:SCALELOCATION ADDRESS: COMCAST JOB NUMBER: STAMPDRAWN BY:GAR02/13/2025WAKVD08500 1X2 (WAKVD05500 2X4)VICINITY MAPCONTACTSPG#SHEET INDEX1COVER SHEET2VICINITY MAP, CONTACTS & SHEET INDEX3GENERAL NOTES4LEGEND5-19SITE-PLAN20TYPICAL DETAILS20N/AN/AVICINITY MAP2PERMITTINGASHLEY KIEHN4610 TACOMA AVESUMNER, WA 98390PHONE: (253) 999-2271EMAIL: ASKIEHN@SEFNCO.COMCOMCASTSEFNCO OPEJOSHUA ASHLEY11308 SW 68TH PKWYTIGARD, OR, 97223PHONE: (503) 939-7931EMAIL: JOSHUA_ASHLEY@COMCAST.COMDOMINIC MINNITI4610 TACOMA AVESUMNER, WA 98390PHONE: (253) 736-4697EMAIL: DMINNITI@SEFNCO.COMDESCRIPTION OF WORKTOTALOVERLASH 48CT FIBER TO EXISTING STRAND (13 POLES)2321LFREPLACE EQUIPMENT AT AERIAL LOCATION (16)REPLACE EQUIPMENT AT UG LOCATION (8)UPGRADE EXISTING METAL PEDESTAL TO DOGHOUSE PEDESTAL (3)UPGRADE EXISTING TOWER PEDESTAL TO NEW DOGHOUSE PEDESTAL (1)TIE IN TO EXISTING SPLICE CASEEXISTING MID SPAN ATTACHMENTTOTAL:2321LFS3S4S5S6S7S14S15S2A A A A A19801 TALBOT RD S,RENTON, WA 98055CONSTRUCTION END19201 97TH AVE S,RENTON, WA 98055CONSTRUCTION BEGIN19167 110TH PL SE,RENTON, WA 98055CUTOVER BEGIN19901 97TH AVE S,RENTON, WA 98055CUTOVER ENDS1MFP25001055 RDIGALERTFDX - WAKVD08600 1X2 - 19167 110TH PL SE RENTON, WA 98055, USA JB0002058033REVISIONSDATEDESCRIPTIONINITIAL COMCASTSHEETOFDATE:EXCEPT AS MAY BE OTHERWISE PROVIDED BY CONTRACT,THESE DRAWINGS AND SPECIFICATIONS SHALL REMAIN THEPROPERTY OF SEFNCO COMMUNICATION, INC. BOTH BEINGISSUED IN STRICT CONFIDENCE AND SHALL NOT BEREPRODUCED, COPIED, OR USED FOR ANY PURPOSEWITHOUT SPECIFIC WRITTEN PERMISSION.SITE NAME:SCALELOCATION ADDRESS: COMCAST JOB NUMBER: STAMPDRAWN BY:GAR02/13/2025WAKVD08500 1X2 (WAKVD05500 2X4)20N/AN/AGENERAL NOTES3 THE LOCATIONS OF UTILITIES SHOWN ON THESE DRAWING ARE ONLY APPROXIMATE. SEFNCO HEREBY DISCLAIMS ANYRESPONSIBILITY TO THIRD PARTIES FOR THE ACCURACY OF THIS INFORMATION. PERSONS WORKING IN THE AREACOVERED BY THIS DRAWING MUST CONTACT THE STATEWIDE CALL-BEFORE-YOU-DIG SYSTEM TO ASCERTAIN THELOCATION OF UNDERGROUND UTILITIES PRIOR TO PERFORMING ANY EXCAVATION.1.ALL MATERIALS, WORKMANSHIP, AND CONSTRUCTION OF UTILITY IMPROVEMENTS SHALL MEET OR EXCEEDSITE WORK STANDARDS AND THE STANDARDS AND SPECIFICATIONS SET FORTH IN THE LOCAL JURISDICTIONREGULATIONS AND APPLICABLE STATE AND FEDERAL REGULATIONS. WHERE THERE IS CONFLICT BETWEENTHESE PLANS AND THE SPECIFICATIONS, OR ANY APPLICABLE STANDARDS, THE HIGHER QUALITY STANDARDSHALL APPLY. ALL WORK WITHIN PUBLIC R.O.W. OR EASEMENTS MAY REQUIRE INSPECTED AND APPROVED BYTHE LOCAL JURISDICTION INSPECTOR. INSPECTION SERVICES AND CONSTRUCTION CERTIFICATION TO BEPROVIDED BY DESIGNEE OF PROJECT SPONSOR/OWNER.2.THE CONTRACTOR IS SPECIFICALLY CAUTIONED THAT THE LOCATION AND/OR ELEVATION OF EXISTINGUTILITIES, AS SHOWN ON THESE PLANS, IS BASED ON RECORDS OF THE VARIOUS UTILITY COMPANIES AND,WHERE POSSIBLE, MEASUREMENTS TAKEN IN THE FIELD. THE INFORMATION IS NOT TO BE RELIED UPON ASBEING EXACT OR COMPLETE. THE CONTRACTOR MUST CALL THE LOCAL UTILITY LOCATION CENTER AT LEAST 48HOURS BEFORE ANY EXCAVATION TO REQUEST EXACT FIELD LOCATIONS OF EXISTING UTILITIES. THECONTRACTOR SHALL VERIFY PERTINENT LOCATIONS AND ELEVATIONS, ESPECIALLY AT THE CONNECTIONPOINTS AND AT POTENTIAL UTILITY CONFLICTS. IT SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR TORELOCATE ALL EXISTING UTILITIES THAT CONFLICT WITH THE PROPOSED IMPROVEMENTS SHOWN ON THESEPLANS.3.THE CONTRACTOR SHALL BE RESPONSIBLE FOR OBTAINING ALL NECESSARY PERMITS FROM ALL APPLICABLEAGENCIES. THE CONTRACTOR SHALL NOTIFY THE LOCAL JURISDICTION INSPECTOR AT LEAST 48 HOURS PRIORTO THE START OF ANY EARTH DISTURBING ACTIVITY OR CONSTRUCTION ON ANY AND ALL PUBLICIMPROVEMENTS IF REQUIRED.4.THE CONTRACTOR SHALL COORDINATE AND COOPERATE WITH THE LOCAL JURISDICTION AND ALL UTILITYCOMPANIES WITH REGARD TO RELOCATIONS OR ADJUSTMENTS OF EXISTING UTILITIES DURINGCONSTRUCTION, TO ASSURE THAT THE WORK IS ACCOMPLISHED IN A TIMELY FASHION, AND WITH A MINIMUMDISRUPTION OF SERVICE. THE CONTRACTOR SHALL BE RESPONSIBLE FOR CONTACTING ALL PARTIESAFFECTED BY ANY DISRUPTION OF ANY UTILITY SERVICE.5.THE CONTRACTOR SHALL HAVE ONE (1) SIGNED COPY OF THE APPROVED PLANS, ONE (1) COPY OF THEAPPROPRIATE STANDARDS AND SPECIFICATIONS, AND ONE (1) COPY OF ANY PERMITS AND EXTENSIONAGREEMENTS NEEDED FOR THE JOB ON-SITE AT ALL TIMES.6.THE CONTRACTOR SHALL BE RESPONSIBLE FOR ALL ASPECTS OF SAFETY INCLUDING, BUT NOT LIMITED TO:EXCAVATION, TRENCHING, SHORING, TRAFFIC CONTROL, AND SECURITY.7.IF, DURING THE CONSTRUCTION PROCESS, CONDITIONS ARE ENCOUNTERED BY THE CONTRACTOR, HISSUBCONTRACTORS, OR OTHER AFFECTED PARTIES WHICH COULD INDICATE A SITUATION THAT IS NOTIDENTIFIED IN THE PLANS OR SPECIFICATIONS, THE CONTRACTOR SHALL CONTACT THE ENGINEERIMMEDIATELY.8.ALL REFERENCES TO ANY PUBLISHED STANDARDS SHALL REFER TO THE LATEST REVISION OF SAID STANDARD,UNLESS SPECIFICALLY STATED OTHERWISE.9.FOR WORK AFFECTING PUBLIC ROADWAYS OR IF REQUIRED BY THE LOCAL JURISDICTION, THE CONTRACTORSHALL SUBMIT A TRAFFIC CONTROL AND PHASING PLAN IN ACCORDANCE WITH M.U.T.C.D. FOR APPROVAL.PRIOR TO ANY CONSTRUCTION ACTIVITIES WITHIN OR AFFECTING THE RIGHT-OF-WAY, THE CONTRACTOR SHALLBE RESPONSIBLE FOR PROVIDING ANY AND ALL TRAFFIC CONTROL DEVICES AS MAY BE REQUIRED BY SAIDPLANS. PRIOR TO INSTALLATION A PRECONSTRUCTION CONFERENCE SHALL BE HELD WITH LOCALJURISDICTION.10.THE CONTRACTOR IS RESPONSIBLE FOR PROVIDING ALL LABOR AND MATERIALS NECESSARY FOR THECOMPLETION OF THE INTENDED IMPROVEMENTS SHOWN ON THESE DRAWINGS OR DESIGNATED TO BEPROVIDED, INSTALLED, CONSTRUCTED, REMOVED OR RELOCATED UNLESS SPECIFICALLY NOTED OTHERWISE.11.PER AGENCY STANDARDS THE CONTRACTOR SHALL BE RESPONSIBLE FOR KEEPING ROADWAYS FREE ANDCLEAR OF ALL CONSTRUCTION DEBRIS AND DIRT TRACKED FROM THE SITE.12.THE CONTRACTOR SHALL BE RESPONSIBLE FOR RECORDING RECORD INFORMATION ON A SET OF RECORDDRAWINGS KEPT AT THE CONSTRUCTION SITE AND AVAILABLE TO THE LOCAL JURISDICTION INSPECTOR AT ALLTIMES.13.DIMENSIONS FOR LAYOUT AND CONSTRUCTION ARE NOT TO BE SCALED FROM ANY DRAWING. FOR ADDITIONALINFORMATION CONTACT THE ENGINEER FOR CLARIFICATION AND NOTE ON THE RECORD DRAWINGS.14.ALL EROSION AND SEDIMENT CONTROL (E.S.C.) MEASURES SHALL BE INSTALLED AT THE LIMITS OFCONSTRUCTION PRIOR TO GROUND DISTURBING ACTIVITY. ALL E.S.C. MEASURES SHALL BE MAINTAINED INGOOD REPAIR BY THE CONTRACTOR UNTIL SUCH TIME AS THE ENTIRE DISTURBED AREAS ARE STABILIZED WITHHARD SURFACE OR LANDSCAPING.15.ALL WORK WITHIN THE PUBLIC RIGHT-OF-WAY IS SUBJECT TO THE JURISDICTION OF THE LOCAL JURISDICTIONENGINEERING DEPARTMENT STANDARD DETAILS AND SPECIFICATIONS.16.ALL CONSTRUCTION OPERATIONS, INCLUDING THE WARMING UP, REPAIR, ARRIVAL, DEPARTURE OR RUNNINGOF TRUCKS, EARTH MOVING EQUIPMENT, CONSTRUCTION EQUIPMENT AND ANY OTHER ASSOCIATEDEQUIPMENT SHALL GENERALLY BE LIMITED TO THE TIME PERIOD APPROVED BY THE LOCAL JURISDICTION.17.CALL THE "CALL BEFORE YOU DIG" NUMBER 48HRS IN ADVANCE AT 1-800-424-5555 PRIOR TO DIGGING.RENTON1.ALL METHODS AND MATERIALS SPECIFICATION SHALL MEET ALL CITY OF RENTON STANDARDS.2.ALL RENTON STANDARD DETAIL DRAWINGS CAN BE FOUND AT THE FOLLOWING WEBSITE:https://edocs.rentonwa.gov/Documents/Browse.aspx?startid=13637033.ALL ASPHALT REPAIR TO BE DONE IN ACCORDANCE WITH RENTON STANDARDS. SEE RENTON STANDARD DETAIL -SECTION F 110.0-110.2.4.ALL SIDEWALK REPAIR TO BE DONE IN ACCORDANCE WITH RENTON STANDARDS. SEE RENTON STANDARD DETAIL- SECTION F 102.0.5.ALL CURB AND GUTTER REPAIR TO BE DONE IN ACCORDANCE WITH RENTON STANDARDS. SEE RENTONSTANDARD DETAIL - SECTION F 103.0.6.UTILITY LOCATIONS SHOWN ON THIS PLAN ARE BASED ON DOCUMENT RESEARCH AND FIELD EVALUATION. THEINFORMATION MAY NOT BE ACCURATE OR COMPLETE. IT IS THE CONTRACTOR'S RESPONSIBILITY TO PHYSICALLYLOCATE AND VERIFY LOCATION AND DEPTH OF ALL UTILITIES WITHIN THE CONSTRUCTION PATH. ALLINSTALLATIONS MUST COMPLY WITH MINIMUM HORIZONTAL AND VERTICAL CLEARANCES FROM UTILITIES.MFP25001055 RDIGALERTFDX - WAKVD08600 1X2 - 19167 110TH PL SE RENTON, WA 98055, USA JB0002058033REVISIONSDATEDESCRIPTIONINITIAL COMCASTSHEETOFDATE:EXCEPT AS MAY BE OTHERWISE PROVIDED BY CONTRACT,THESE DRAWINGS AND SPECIFICATIONS SHALL REMAIN THEPROPERTY OF SEFNCO COMMUNICATION, INC. BOTH BEINGISSUED IN STRICT CONFIDENCE AND SHALL NOT BEREPRODUCED, COPIED, OR USED FOR ANY PURPOSEWITHOUT SPECIFIC WRITTEN PERMISSION.SITE NAME:SCALELOCATION ADDRESS: COMCAST JOB NUMBER: STAMPDRAWN BY:GAR02/13/2025WAKVD08500 1X2 (WAKVD05500 2X4)20N/AN/ALEGEND 4LEGENDTELECOMMUNICATIONSANITARY SEWERGAS LINEWATERSTORM DRAINRECYCLED WATERPOWERPARCEL LINERIGHT OF WAYDITCH LINECENTER LINEEDGE OF PAVEMENTFACE OF CURBPROPERTY LINELIP OF GUTTERGUARDRAILSDSDWWSSSSGGTTLIPD/LEOPFOCRWRWBUILDING OUTLINEPFLFOG LINESIDEWALKSWSWTRENCHDIRECT BOREPROPOSED AERIAL STRAND PROOF/PULLPROPOSED OVERLASHMINOR ARTERIALCOLLECTOR ARTERIALINTERSTATE FREEWAYACCESS STREETPRINCIPAL ARTERIALBUILDINGR/WWARNING SIGN PLACEMENT (W/ PART #)TRAFFIC BARRELHYDRO-VAC TRENCHKEEPRIGHTREGULATORY SIGN (W/ PART #)LIMITSPEEDR2-125SPEED LIMIT CALLOUTSIGN PLACEMENT / DIRECTIONTRAFFIC CONEFLAGGER STATIONFLAGGER STATIONPATROL CARPOLICEOFFICERUNIFORMED POLICE OFFICERWORK VEHICLEFENCESTREET LIGHT HANDHOLETELECOM MANHOLETELECOM HANDHOLETELECOM CABINETTRAFFIC SIGNAL MANHOLETRAFFIC CABINETTRAFFIC SIGNAL PEDESTALSTREET LIGHT POLETRAFFIC SIGNAL HANDHOLECATV MANHOLECATV HANDHOLECATV PEDESTALTRAFFIC SIGNAL POLESTORM MANHOLEWATER VALVEWATER METERTELECOM PEDESTALSTORM INLETSTORM DRAIN UNKNOWN D?SISEWER VALVESSEWER VAULT SSSEWER UNKNOWN S?STORM DRAIN VAULT SDSEWER CLEANOUTSEWER MANHOLESCSEWER CATCH BASIN SSSTORM ACCESS POINTBASE LAYERSEXISTING UTILITIESROAD HATCH CLASSIFICATIONROW WORK LINETYPECOMCAST UNDERGROUND SYMBOLSEXISTING UTILITY SYMBOLSTRAFFIC CONTROL SYMBOLSSTORM CATCH BASIN SDTRAFFIC SIGNAL VAULTGAS METERTEST VALVEPEDESTAL UNK UTILITYFIRE HYDRANTGAS VALVEGAS TEST POINTGAS MANHOLEWATER PUMPGGGWATER AIR CONTROL VALVEWATER WELLWATER SAMPLING STATIONPOWER HANDHOLEPOWER MANHOLEPOWER CABINETPOWER VAULTPOWER PEDESTALPPOWER UNKNOWN PPPPPP?SIGN POSTCULVERTTRANSIT STOPBUSSTOPDRIVEWAY (FOC OR EOP)SDSSANCHORSIDEWALK ANCHOR & GUY(P) FIBER & COUNTF48(P) .625 COAX(P) .875 COAXCOMCAST AERIAL SYMBOLSPROPOSEDEXISTINGWRECKOUTPOLE W/O RISERRISERARMVERTICAL GROUNDSLACK SPANOVERHEAD GUYTANGENT ATTACHMENTDEAD-ENDDOUBLE DEAD-END(E) FIBER & COUNTF48(E) .625 COAX(E) .875 COAXSLSLTSTSTSTSCCCTTTTTSTS?PUMPFWELLTREE TRIMLIGHT/MEDIUM/HEAVYLMH//WRECKOUTVAULTSPLICE CASEMANHOLENode SymbolPEDESTALNode SymbolNode SymbolPAMINIBRIDGERTTTAATAPAMPLIFER POTHOLEBORE PIT / EXCAVATIONMMMPROPOSEDEXISTINGWRECKOUTNODENode SymbolABCDNode SymbolSTORAGE LOOPX'X'LIT INTERSECTIONFASFLASHING ARROWSEQUENTIAL ARROWSEQUENTIAL CHEVRONFLASHING DOUBLE ARROW(MERGE LEFT OR RIGHT)FLASHING CAUTIONORFLASHING DIAMOND CAUTIONARROWBOARD PLACEMENT (SEE BELOW)CHANNELIZING DEVICES / MIN DIMENSIONSNOTE(S):1.AN ARROWBOARD SHALL MEET THE MINIMUM SIZE, LEGIBILITYDISTANCE, NUMBER OF ELEMENTS AND OTHERSPECIFICATIONS SHOWN.2.LENGTH OF ARROW EQUALS 48", WIDTH OF ARROWHEADEQUALS 24".3.TYPE A, B AND C ARROW BOARDS SHALL HAVE SOLIDRECTANGULAR APPEARANCES. A TYPE D ARROW BOARDSHALL CONFORM TO THE SHAPE OF THE ARROW.ARROWBOARD TYPE MIN LEGIBILITYDISTANCEMIN SIZE MINIMUM# OFELEMENTSABCD48"×24"60"×30"96"×48"NONE12 MILE1 MILE34 MILE12 MILE121315125FT MIN4FT MIN8-12"45°TYPE 3 BARRICADE3FT MIN45°2FT MIN8-12"TYPE 1 BARRICADE3FT MIN8-12"2FT MIN45°TYPE 2 BARRICADE3-4"6"2"4"28'-36" MAXSPEED < 45MPHNIGHT AND/OR FREEWAYMORE THAN 36"4-6" TYPCONECONESPEED ≥ 45MPHDIRECTION INDICATOR BARRICADE12"8"36" MIN 24" MIN45°UNLIT INTERSECTIONDBTRENCHAVAC-TSPOTTER STATIONALL TRAFFIC CONTROL DEVICES / ANNOTATIONS PER MUTCDAMPLIFIER PICTURETAP PICTUREEquipmentMFP25001055 R/WR/W R/W R/WR/WR/W R/WR/WR/WR/W R/W R/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WFOCFOC FOC FOCFOCFOCFOC FOCFOCFOCFOCP P 110TH PL SE 110TH PL SE19167 1916611014191681912219167110TH PL SE110TH PL SESW SW SW SWSW SWRDIGALERTFDX - WAKVD08600 1X2 - 19167 110TH PL SE RENTON, WA 98055, USA JB0002058033REVISIONSDATEDESCRIPTIONINITIAL COMCASTSHEETOFDATE:EXCEPT AS MAY BE OTHERWISE PROVIDED BY CONTRACT,THESE DRAWINGS AND SPECIFICATIONS SHALL REMAIN THEPROPERTY OF SEFNCO COMMUNICATION, INC. BOTH BEINGISSUED IN STRICT CONFIDENCE AND SHALL NOT BEREPRODUCED, COPIED, OR USED FOR ANY PURPOSEWITHOUT SPECIFIC WRITTEN PERMISSION.SITE NAME:SCALELOCATION ADDRESS: COMCAST JOB NUMBER: STAMPDRAWN BY:GAR02/13/2025WAKVD08500 1X2 (WAKVD05500 2X4)20SITE PLAN - 1 5N1SITE PLAN CONSTRUCTION NOTES11UPGRADE EXISTING METAL PEDESTALTO DOGHOUSE PEDESTALTO DOGHOUSE PEDESTAL2REPLACE EQUIPMENT AT UG LOCATION22MFP25001055 R/WR/WR/WR/W POLE EOP EOP EOP EOP EOP EOP EOP EOP R/W R/W R/W R/W R/W R/W 19032190401903719015106TH AVE SE 106TH AVE SE R/W R/W R/W R/W R/W R/W R/W R/W R/W RDIGALERTFDX - WAKVD08600 1X2 - 19167 110TH PL SE RENTON, WA 98055, USA JB0002058033REVISIONSDATEDESCRIPTIONINITIAL COMCASTSHEETOFDATE:EXCEPT AS MAY BE OTHERWISE PROVIDED BY CONTRACT,THESE DRAWINGS AND SPECIFICATIONS SHALL REMAIN THEPROPERTY OF SEFNCO COMMUNICATION, INC. BOTH BEINGISSUED IN STRICT CONFIDENCE AND SHALL NOT BEREPRODUCED, COPIED, OR USED FOR ANY PURPOSEWITHOUT SPECIFIC WRITTEN PERMISSION.SITE NAME:SCALELOCATION ADDRESS: COMCAST JOB NUMBER: STAMPDRAWN BY:GAR02/13/2025WAKVD08500 1X2 (WAKVD05500 2X4)20SITE PLAN - 2 6N1SITE PLAN CONSTRUCTION NOTESREPLACE EQUIPMENT AT AERIALLOCATION1MFP25001055 R/W R/W R/W R/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/W R/W R/W R/WR/WR/WR/WR/WR/WR/W R/W R/W R/W R/WR/WR/WR/WPOLEFLFLFLFLFLFLFLFLFLFLEOPEOPEOPEOP FLFLFLFLFLFLFLEOP EOPFLFLFLFLFLFLFLFLFLFLEOPEOPEOP EOP EOP EOP EOPEOPEOP19207106071906019059SE 192ND STSE 192ND ST106TH AVE SE 106TH AVE SE 107TH AVE SE EOPEOPR/W R/W RDIGALERTFDX - WAKVD08600 1X2 - 19167 110TH PL SE RENTON, WA 98055, USA JB0002058033REVISIONSDATEDESCRIPTIONINITIAL COMCASTSHEETOFDATE:EXCEPT AS MAY BE OTHERWISE PROVIDED BY CONTRACT,THESE DRAWINGS AND SPECIFICATIONS SHALL REMAIN THEPROPERTY OF SEFNCO COMMUNICATION, INC. BOTH BEINGISSUED IN STRICT CONFIDENCE AND SHALL NOT BEREPRODUCED, COPIED, OR USED FOR ANY PURPOSEWITHOUT SPECIFIC WRITTEN PERMISSION.SITE NAME:SCALELOCATION ADDRESS: COMCAST JOB NUMBER: STAMPDRAWN BY:GAR02/13/2025WAKVD08500 1X2 (WAKVD05500 2X4)20SITE PLAN - 3 7N1SITE PLAN CONSTRUCTION NOTESREPLACE EQUIPMENT AT AERIALLOCATION1SE 192ND STMFP25001055 R/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WPOLEPOLEFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFOCR/WR/WR/WR/WR/WR/W R/WR/WFLR/WR/WR/WR/WR/WFOCFOCFOCFOCEOPEOPFOCFO C FOCFOC 104211042410420191291032610321SE 192ND STSE 192ND ST104TH PL SEEOP EOPEOPEOPSWSWSWSWSWSWSWSWSWSWSW SWSW RDIGALERTFDX - WAKVD08600 1X2 - 19167 110TH PL SE RENTON, WA 98055, USA JB0002058033REVISIONSDATEDESCRIPTIONINITIAL COMCASTSHEETOFDATE:EXCEPT AS MAY BE OTHERWISE PROVIDED BY CONTRACT,THESE DRAWINGS AND SPECIFICATIONS SHALL REMAIN THEPROPERTY OF SEFNCO COMMUNICATION, INC. BOTH BEINGISSUED IN STRICT CONFIDENCE AND SHALL NOT BEREPRODUCED, COPIED, OR USED FOR ANY PURPOSEWITHOUT SPECIFIC WRITTEN PERMISSION.SITE NAME:SCALELOCATION ADDRESS: COMCAST JOB NUMBER: STAMPDRAWN BY:GAR02/13/2025WAKVD08500 1X2 (WAKVD05500 2X4)20SITE PLAN - 4 8N1SITE PLAN CONSTRUCTION NOTESREPLACE EQUIPMENT AT AERIALLOCATION11MFP25001055 R/WR/W R/WR/WR/WR/WR/WR/WR/WR/WR/WR/W R/W R/WFLFLFLFLFOCFOCF O CFOC R/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WFOCFOCFOCFOCFOC FOCFOCPOLEPOLE PFLFLFLFLFLFLFLFLFLR/WR/WR/WR/WFOC FOC FOCFOCFOCFOCFOC FOC FOCFOC10159192181011310119101121921319202192081904510204SE 192ND STSE 192ND ST102ND AVE SE 102ND AVE SE SE 192ND PLSE 192ND PL101ST AVE SE(PRIVATE RD) 101ST PL SE (PRIVATE RD) 102ND AVE SE EOPEOPEOP FOC FOCFOCFOCFOCFOCFOCSWSWSW SW SWSWSWSWSWSWSWSWRDIGALERTFDX - WAKVD08600 1X2 - 19167 110TH PL SE RENTON, WA 98055, USA JB0002058033REVISIONSDATEDESCRIPTIONINITIAL COMCASTSHEETOFDATE:EXCEPT AS MAY BE OTHERWISE PROVIDED BY CONTRACT,THESE DRAWINGS AND SPECIFICATIONS SHALL REMAIN THEPROPERTY OF SEFNCO COMMUNICATION, INC. BOTH BEINGISSUED IN STRICT CONFIDENCE AND SHALL NOT BEREPRODUCED, COPIED, OR USED FOR ANY PURPOSEWITHOUT SPECIFIC WRITTEN PERMISSION.SITE NAME:SCALELOCATION ADDRESS: COMCAST JOB NUMBER: STAMPDRAWN BY:GAR02/13/2025WAKVD08500 1X2 (WAKVD05500 2X4)20SITE PLAN - 5 9NREPLACE EQUIPMENT AT UGLOCATION12SITE PLAN CONSTRUCTION NOTESREPLACE EQUIPMENT AT AERIALLOCATION112MFP25001055 R/W R/WR/WR/W R/W R/W R/WR/WR/WR/WR/WR/WR/W FLFLFLFLFLFLFLFLFLFL FL FL FLFLFLFLFLFLFLFLFLFLFLFLFL FL FL FLFLFLFLFLR/W R/W R/WR/WR/WR/WR/WPOLE PO L E1921119219192181921019203 10003750SE 1 9 2 N D S TS 55TH ST99TH PL S EOPEOPEOP EOPEOPEOP SE 192ND PLRDIGALERTFDX - WAKVD08600 1X2 - 19167 110TH PL SE RENTON, WA 98055, USA JB0002058033REVISIONSDATEDESCRIPTIONINITIAL COMCASTSHEETOFDATE:EXCEPT AS MAY BE OTHERWISE PROVIDED BY CONTRACT,THESE DRAWINGS AND SPECIFICATIONS SHALL REMAIN THEPROPERTY OF SEFNCO COMMUNICATION, INC. BOTH BEINGISSUED IN STRICT CONFIDENCE AND SHALL NOT BEREPRODUCED, COPIED, OR USED FOR ANY PURPOSEWITHOUT SPECIFIC WRITTEN PERMISSION.SITE NAME:SCALELOCATION ADDRESS: COMCAST JOB NUMBER: STAMPDRAWN BY:GAR02/13/2025WAKVD08500 1X2 (WAKVD05500 2X4)20SITE PLAN - 6 10N1SITE PLAN CONSTRUCTION NOTESREPLACE EQUIPMENT AT AERIALLOCATION11MFP25001055 R/WR/WR/WR/WR/WR/W R/ W R/ W R/WR/WR/WR/WR/WR/W R/WR/WR/WR/WR/WR/WR/WR/WR/W R/WFLFLFLFLFLFLFLFLFOCFOCFOCFOCFOCFOCR/WFOC FOCFOCR/W R/WR/WR/WEOPEOPEOPFLFLFLFLFLFL FL FL FL FLFLFLFLFLF LFL FL FL FL FLFLFLFLFLFLFLFLFLFLFLEOPEOPEOP POLEEOPEOPEOPEOP S 55T H S TS 55TH STS 55TH STS 55TH ST 98TH AVE S965119203520498EOPPR/W SWSWSWSWRDIGALERTFDX - WAKVD08600 1X2 - 19167 110TH PL SE RENTON, WA 98055, USA JB0002058033REVISIONSDATEDESCRIPTIONINITIAL COMCASTSHEETOFDATE:EXCEPT AS MAY BE OTHERWISE PROVIDED BY CONTRACT,THESE DRAWINGS AND SPECIFICATIONS SHALL REMAIN THEPROPERTY OF SEFNCO COMMUNICATION, INC. BOTH BEINGISSUED IN STRICT CONFIDENCE AND SHALL NOT BEREPRODUCED, COPIED, OR USED FOR ANY PURPOSEWITHOUT SPECIFIC WRITTEN PERMISSION.SITE NAME:SCALELOCATION ADDRESS: COMCAST JOB NUMBER: STAMPDRAWN BY:GAR02/13/2025WAKVD08500 1X2 (WAKVD05500 2X4)20SITE PLAN - 7 11N1SITE PLAN CONSTRUCTION NOTESREPLACE EQUIPMENT AT AERIALLOCATION12UPGRADE EXISTING TOWER PEDESTALTO NEW DOGHOUSE PEDESTAL3REPLACE EQUIPMENT AT UG LOCATION23MFP25001055 R/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WA A A A A A A A A A A A AAAAAAAAAAAP FOCFOCFOCFOC FOCR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WFL FLFLFL R/WR/WR/WR/WR/WR/WR/WR/WFOCFOCR/WR/WR/WR/WR/WR/WR/WR/W R/W R/W FLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFOCFOCR/WR/WR/WFOC FOC FLFLFLFLFLFLFLFLFLFLFL496S 55TH STS 192ND STTALBOT RD STALBOT RD S 97TH AVE S 1920019201960919225192241921819212EOP EOP EOP EOPEOPEOPEOPEOPEOPEOPEOPF O C FOC FOC FOC FOC124'108'9'200'1923154209533S 55TH ST (PRIVATE RD)POLE 1POLE 2POLE 3POLE 4 SWSWSWSW SW SW SWSWSWSWSWSW SW SWSW SW SW SW SW SW SWSW S 55TH STMATCH TO SITE PLAN - 9RDIGALERTFDX - WAKVD08600 1X2 - 19167 110TH PL SE RENTON, WA 98055, USA JB0002058033REVISIONSDATEDESCRIPTIONINITIAL COMCASTSHEETOFDATE:EXCEPT AS MAY BE OTHERWISE PROVIDED BY CONTRACT,THESE DRAWINGS AND SPECIFICATIONS SHALL REMAIN THEPROPERTY OF SEFNCO COMMUNICATION, INC. BOTH BEINGISSUED IN STRICT CONFIDENCE AND SHALL NOT BEREPRODUCED, COPIED, OR USED FOR ANY PURPOSEWITHOUT SPECIFIC WRITTEN PERMISSION.SITE NAME:SCALELOCATION ADDRESS: COMCAST JOB NUMBER: STAMPDRAWN BY:GAR02/13/2025WAKVD08500 1X2 (WAKVD05500 2X4)20SITE PLAN - 8 12N1TIE INTO EXISTING SPLICE CASE.1SITE PLAN CONSTRUCTION NOTES234EXISTING POLE (1-4).OVERLASH 48CT FIBER TO EXISTINGSTRAND.EXISTING MID SPAN ATTACHMENT.REPLACE EQUIPMENT AT UGLOCATION56REPLACE EQUIPMENT AT AERIALLOCATION232343253236MFP25001055 A A A A A A A AAAAA A A A A A A A PR/WR/WR/WR/WR/WR/WR/WR/WR/WR/W R/WR/WR/W R/ WFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFL R/WR/WR/WR/WR/WR/WR/WR/WR/W R/W R/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WFLFOCFOCFOCFOCFOCFOCFOCFOCTALBOT RD STALBOT RD S S 194TH STS 194TH ST9612961519221963396379640221'FOCFOCFOCFOCFOCFO C FOCEOP EOP EOP EOP169'EOP 97TH AVE S POLE 5POLE 6SWSWSWSW SWSWSWSWSWSWSWSWSWSWSW SW SW SW SW SW SW SW SW SWSWSWSWS WSW SWSWSW MATCH TO SITE PLAN -8MATCH TO SITE PLAN - 10RDIGALERTFDX - WAKVD08600 1X2 - 19167 110TH PL SE RENTON, WA 98055, USA JB0002058033REVISIONSDATEDESCRIPTIONINITIAL COMCASTSHEETOFDATE:EXCEPT AS MAY BE OTHERWISE PROVIDED BY CONTRACT,THESE DRAWINGS AND SPECIFICATIONS SHALL REMAIN THEPROPERTY OF SEFNCO COMMUNICATION, INC. BOTH BEINGISSUED IN STRICT CONFIDENCE AND SHALL NOT BEREPRODUCED, COPIED, OR USED FOR ANY PURPOSEWITHOUT SPECIFIC WRITTEN PERMISSION.SITE NAME:SCALELOCATION ADDRESS: COMCAST JOB NUMBER: STAMPDRAWN BY:GAR02/13/2025WAKVD08500 1X2 (WAKVD05500 2X4)20SITE PLAN - 9 13N12123141SITE PLAN CONSTRUCTION NOTES234OVERLASH 48CT FIBER TO EXISTINGSTRAND.EXISTING POLE (5-6).UPGRADE EXISTING METAL PEDESTALTO DOGHOUSE PEDESTALREPLACE EQUIPMENT AT AERIALLOCATIONMFP25001055 R/WR/WA A A A A A A A A A A A A A A A A A A A R/W R/W R/WR/WR/WR/WR/WR/WR/WR/WFL FL FL FL FLFLFLFLFLFLFLFLFL FL FL FL FLFLFLFLFLFLFLFLFLEOP EOP R/W R/W R/W R/W R/W R/W R/W TALBOT RD S TALBO T R D S 224' 196' 179'1941519418EOP EOP EOP EOP EOP EOP EOP POLE 7 POLE 8 RDIGALERTFDX - WAKVD08600 1X2 - 19167 110TH PL SE RENTON, WA 98055, USA JB0002058033REVISIONSDATEDESCRIPTIONINITIAL COMCASTSHEETOFDATE:EXCEPT AS MAY BE OTHERWISE PROVIDED BY CONTRACT,THESE DRAWINGS AND SPECIFICATIONS SHALL REMAIN THEPROPERTY OF SEFNCO COMMUNICATION, INC. BOTH BEINGISSUED IN STRICT CONFIDENCE AND SHALL NOT BEREPRODUCED, COPIED, OR USED FOR ANY PURPOSEWITHOUT SPECIFIC WRITTEN PERMISSION.SITE NAME:SCALELOCATION ADDRESS: COMCAST JOB NUMBER: STAMPDRAWN BY:GAR02/13/2025WAKVD08500 1X2 (WAKVD05500 2X4)20SITE PLAN - 10 14N12121MATCH TO SITE PLAN - 9MATCH TO SITE PLAN - 111SITE PLAN CONSTRUCTION NOTES2OVERLASH 48CT FIBER TO EXISTINGSTRAND.EXISTING POLE (7-8).MFP25001055 A A A A A A A A A A A A A A A A A A A A R/WR/WFLFLFLFLFLFLFLFLFLFLFLFLFLFLFOCR/W R/WR/WR/WR/WR/WR/WR/W R/W R/W R/W R/W EOP EOP EOP EOP EOP EOP EOP EOP R/W R/W R/W R/W R/W R/W R/W R/W R/W R/W 204' TALB O T R D S TALB O T R D S S 196TH PL19464194259497EOP FOC FOC FOCFOCFOCFOC FOC FOC FOC FOC POLE 9 POLE 1 0SW SW SWSWSW RDIGALERTFDX - WAKVD08600 1X2 - 19167 110TH PL SE RENTON, WA 98055, USA JB0002058033REVISIONSDATEDESCRIPTIONINITIAL COMCASTSHEETOFDATE:EXCEPT AS MAY BE OTHERWISE PROVIDED BY CONTRACT,THESE DRAWINGS AND SPECIFICATIONS SHALL REMAIN THEPROPERTY OF SEFNCO COMMUNICATION, INC. BOTH BEINGISSUED IN STRICT CONFIDENCE AND SHALL NOT BEREPRODUCED, COPIED, OR USED FOR ANY PURPOSEWITHOUT SPECIFIC WRITTEN PERMISSION.SITE NAME:SCALELOCATION ADDRESS: COMCAST JOB NUMBER: STAMPDRAWN BY:GAR02/13/2025WAKVD08500 1X2 (WAKVD05500 2X4)20SITE PLAN - 11 15N11SITE PLAN CONSTRUCTION NOTES2OVERLASH 48CT FIBER TO EXISTINGSTRAND.EXISTING POLE (9-10).3REPLACE EQUIPMENT AT AERIALLOCATION23121MATCH TO SITE PLAN - 10MATCH TO SITE PLAN - 12MFP25001055 A A A A A A A A A A A A A A A A A A A A P PFLFLFLFOC FOC FOC FOC FOC R/WR/WR/WR/WR/W R /WR/WR/WR/WFLFLFLFLFLFLFLFLFLEOP EOP R/W R/W R/W R/W R/W R/W R/W R/W R/W R/W R/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/W215'FOCFOCF O CS 196 PLR/W R/W949194851964319653TALBO T R D S TALBO T R D S S 198TH ST 19640196461970019652EOPEOPFOCFOCFOC233' 239' POLE 1 1 POLE 1 2 SW SW SW SWSWSWSWSWSWSW SWSWSWSW SW SWSWS 196 PLRDIGALERTFDX - WAKVD08600 1X2 - 19167 110TH PL SE RENTON, WA 98055, USA JB0002058033REVISIONSDATEDESCRIPTIONINITIAL COMCASTSHEETOFDATE:EXCEPT AS MAY BE OTHERWISE PROVIDED BY CONTRACT,THESE DRAWINGS AND SPECIFICATIONS SHALL REMAIN THEPROPERTY OF SEFNCO COMMUNICATION, INC. BOTH BEINGISSUED IN STRICT CONFIDENCE AND SHALL NOT BEREPRODUCED, COPIED, OR USED FOR ANY PURPOSEWITHOUT SPECIFIC WRITTEN PERMISSION.SITE NAME:SCALELOCATION ADDRESS: COMCAST JOB NUMBER: STAMPDRAWN BY:GAR02/13/2025WAKVD08500 1X2 (WAKVD05500 2X4)20SITE PLAN - 12 16N1MATCH TO SITE PLAN - 11MATCH TO SITE PLAN - 132121331SITE PLAN CONSTRUCTION NOTES2OVERLASH 48CT FIBER TO EXISTINGSTRAND.EXISTING POLE (11-12).3REPLACE EQUIPMENT AT UGLOCATIONMFP25001055 R/WR/WR/WR/WR/WR/WR/WR/W A A A A POLE FLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLEOP EOP R/W R/W R/W R/W R/W R/W R/W R/W R/W R/W R/WR/WR/WR/WR/WR/WR/WFLEOPEOPEOP19801952219809TALB O T R D S TALBO T R D S TALBOT RD S S 199TH ST19706198081981695139507EOPEOP EOPEOPFOCPOLE 1 3 SWSW RDIGALERTFDX - WAKVD08600 1X2 - 19167 110TH PL SE RENTON, WA 98055, USA JB0002058033REVISIONSDATEDESCRIPTIONINITIAL COMCASTSHEETOFDATE:EXCEPT AS MAY BE OTHERWISE PROVIDED BY CONTRACT,THESE DRAWINGS AND SPECIFICATIONS SHALL REMAIN THEPROPERTY OF SEFNCO COMMUNICATION, INC. BOTH BEINGISSUED IN STRICT CONFIDENCE AND SHALL NOT BEREPRODUCED, COPIED, OR USED FOR ANY PURPOSEWITHOUT SPECIFIC WRITTEN PERMISSION.SITE NAME:SCALELOCATION ADDRESS: COMCAST JOB NUMBER: STAMPDRAWN BY:GAR02/13/2025WAKVD08500 1X2 (WAKVD05500 2X4)20SITE PLAN - 13 17N1MATCH TO SITE PLAN - 122341SITE PLAN CONSTRUCTION NOTES2OVERLASH 48CT FIBER TO EXISTINGSTRAND.EXISTING POLE (13).3END OVERLASH AT EXISTINGSPLICE CASE.4REPLACE EQUIPMENT AT AERIALLOCATIONMFP25001055 R/W R/W R/W POLE FOC EOPR/W R/W R/W R/W R/W R/W R/W S 198TH ST92ND AVE S FOC9204920590599713EOPEOP EOPFOC FOC FOC FOCFOCRDIGALERTFDX - WAKVD08600 1X2 - 19167 110TH PL SE RENTON, WA 98055, USA JB0002058033REVISIONSDATEDESCRIPTIONINITIAL COMCASTSHEETOFDATE:EXCEPT AS MAY BE OTHERWISE PROVIDED BY CONTRACT,THESE DRAWINGS AND SPECIFICATIONS SHALL REMAIN THEPROPERTY OF SEFNCO COMMUNICATION, INC. BOTH BEINGISSUED IN STRICT CONFIDENCE AND SHALL NOT BEREPRODUCED, COPIED, OR USED FOR ANY PURPOSEWITHOUT SPECIFIC WRITTEN PERMISSION.SITE NAME:SCALELOCATION ADDRESS: COMCAST JOB NUMBER: STAMPDRAWN BY:GAR02/13/2025WAKVD08500 1X2 (WAKVD05500 2X4)20SITE PLAN - 14 18N1SITE PLAN CONSTRUCTION NOTESREPLACE EQUIPMENT AT AERIALLOCATION1MFP25001055 R/W R/W R/WR/WR/WR/WR/WR/W R/WR/WR/W POLEEOPEOPEOPEOPFOC FOC FOC97TH AVE SS 198TH PL (PRIVATE RD)97T H A V E S 199019615961619834FOC FOC FOC FOCFOCFOCFOC FOC FOCRDIGALERTFDX - WAKVD08600 1X2 - 19167 110TH PL SE RENTON, WA 98055, USA JB0002058033REVISIONSDATEDESCRIPTIONINITIAL COMCASTSHEETOFDATE:EXCEPT AS MAY BE OTHERWISE PROVIDED BY CONTRACT,THESE DRAWINGS AND SPECIFICATIONS SHALL REMAIN THEPROPERTY OF SEFNCO COMMUNICATION, INC. BOTH BEINGISSUED IN STRICT CONFIDENCE AND SHALL NOT BEREPRODUCED, COPIED, OR USED FOR ANY PURPOSEWITHOUT SPECIFIC WRITTEN PERMISSION.SITE NAME:SCALELOCATION ADDRESS: COMCAST JOB NUMBER: STAMPDRAWN BY:GAR02/13/2025WAKVD08500 1X2 (WAKVD05500 2X4)20SITE PLAN - 15 19N1SITE PLAN CONSTRUCTION NOTESREPLACE EQUIPMENT AT AERIALLOCATION1MFP25001055 20REVISIONSDATEDESCRIPTIONINITIALRDIGALERTFDX - WAKVD08600 1X2 - 19167 110TH PL SE RENTON, WA 98055, USA JB0002058033REVISIONSDATEDESCRIPTIONINITIAL COMCASTSHEETOFDATE:EXCEPT AS MAY BE OTHERWISE PROVIDED BY CONTRACT,THESE DRAWINGS AND SPECIFICATIONS SHALL REMAIN THEPROPERTY OF SEFNCO COMMUNICATION, INC. BOTH BEINGISSUED IN STRICT CONFIDENCE AND SHALL NOT BEREPRODUCED, COPIED, OR USED FOR ANY PURPOSEWITHOUT SPECIFIC WRITTEN PERMISSION.SITE NAME:SCALELOCATION ADDRESS: COMCAST JOB NUMBER: STAMPDRAWN BY:GAR02/13/2025WAKVD08500 1X2 (WAKVD05500 2X4)NTS20TYPICAL DETAILS AERIAL TYPICALSMFP25001055 ___________________________________________________________________________________ MasTec Network Solutions 4610 Tacoma Ave Sumner, WA 98390 ____________________________________________________________________________________________________________ MasTec Washington Locations Spokane ~ Puget Sound March 3, 2025 To whom it may concern: City of Renton 1055 South Grady Way Renton, WA 98057 RE: Aerial Variance Request for JB0002058033 To whom it may concern, Mastec North America has been contracted to design and engineer this project on behalf of Comcast Cablevision. Comcast is applying for a variance request in order to upgrade their existing facilities. Comcast proposes to overlash 48ct fiber to existing strand; replace existing equipment at aerial and UG locations; upgrade metal pedestals to doghouses; tie into existing splice case. Comcast is requesting that the City of Renton approve this variance request based on the fact that the requirements for undergrounding this proposed over-lash will not cause substantial adverse impacts to other person or entities in the immediate area and will cause undue hardship. 1. Installation of undergrounding facilities will increase the total cost of construction roughly 15-25 times the amount of an aerial over-lash on the existing Comcast strand. 2. Potential damage to underground facilities will be increased. 3. Over-lash will not cause substantial adverse impact to other persons or entities in the immediate area. Over-lashing the cable will be accomplished in a few days, and the residents will not notice any impact. Comcast will clean up the over-lashed spans as necessary and identify and remove any existing dead cables along this route. 4. The variance is necessary to prevent and undue hardship due to the increased construction costs if forced to install the proposed extension underground. 5. The granting of the variance will not be materially detrimental to the public welfare because Comcast does agree to underground the cable system, but they are waiving the obligation into the future when all other utilities are underground to prevent an undue hardship against Comcast currently. Upon the granting of the Variance, Comcast will coordinate construction and traffic control as per your requirements. Comcast and their contractors want to cooperate at the highest level and agree to adhere to all provisions and requirements set forth by the City of Renton to insure safe installation and maintenance of the proposed facilities. ___________________________________________________________________________________ MasTec Network Solutions 4610 Tacoma Ave Sumner, WA 98390 ____________________________________________________________________________________________________________ MasTec Washington Locations Spokane ~ Puget Sound If you have any further questions regarding this project please contact Dominic Minniti at 253-736-4697. Thank you for your consideration in this matter. Ashley Kiehn Ashley Kiehn Director of Operations Support MasTec North America Cell (253)797-8118 | Ashley.Kiehn@mastec.com Attachments: 1. Application for ROW permit 2. 11” x 17” Site plan 3. 11” x 17” Design plan 4. Traffic Control Plan March 20, 2025 Ashley Kiehn Mastec North America 4610 Tacoma Avenue, Sumner WA 98390 Via Email: Ashley.Kiehn@mastec.com SUBJECT: Request for Undergrounding Exemption (JB#2058033, MFP25001055, 19167 110th PL SE) Dear Ms. Kiehn: The City of Renton has reviewed your request to grant Comcast an exemption from Renton Municipal Code (RMC) 4-6-090(C) which states that all new electrical or communication facilities shall be required to be installed underground, pursuant to the standards of the section of RMC. Comcast proposes to have Mastec North America overlash new fiber for a total of approximately 2,321 lineal feet to existing Puget Sound Energy (PSE) poles along Talbot Rd S and SE 192nd St within the city. See the enclosed Site Plan showing the proposed overlashing limits. ANALYSIS: The City has considered the request for an exemption from RMC 4-6-090. Ordinance 5720 grants Comcast, the right to install fiber optic cable and related appurtenances under, along, over, below, through and across the streets, avenues and alleys of City of Renton within the right-of-way of Renton. Section 3.4 of the franchise ordinance states that if all of the distribution lines all the wireline service providers, such as telecommunications service providers, as defined in RCW 35.99.010, a utility service provider or a Cable Operator (collectively “Service Providers”) in any portion of the Franchise Area are underground, Grantee shall place its Cable System’s distribution cables underground within that area; provided that such underground locations are actually capable of accommodating Grantee’s cable and other equipment without technical degradation of the Cable Systems’ signal quality. The proposal would utilize existing poles with other attached franchisee communication facilities and overlash to the existing Comcast aerial path. As minimum vertical height clearance of 15’-6” would need to be provided for, any existing obsolete cable will need to be removed; staff recommends these as conditions of approval. Therefore, the City is granting an exemption with conditions, per the Comcast franchise agreement which allows new overhead facilities to be placed overhead provided there are other similar providers overhead as well. Comcast is required to obtain all necessary private utility easements for work on private property. DECISION: The requested exemption from underground utility installation requirements RMC4-6-090 (C) as requested by the applicant is approved with conditions subject to the conditions below as the request complies with the Comcast Franchise Agreement. Comcast Job JB#2058033 Page 2 of 2 March 20, 2025 Conditions of Approval: 1. Any existing height violations within the Project Reach must be resolved at the time of construction. New aerial lines within the Project Reach must have a minimum vertical clearance of 15’-6”. 2. Any abandoned or unused lines within the Project Reach must be removed at the time that construction is taking place. 3. A traffic control plan must be separately submitted to the City, and no construction may take place until the City has approved a traffic control plan. 4. The new aerial fiber lines within the Project Reach must be converted to underground facilities in the future, at the Applicant’s cost, when any one of the following events occurs: (1) any other utilities are undergrounded within the Project Reach, (2) a joint use trench is proposed by a franchisee within the Project Reach, in which case the Applicant shall participate in the joint use trench installation for the purpose of undergrounding its aerial lines, or (3) a conduit is made available within the Project Reach that will accommodate the aerial lines. The new aerial lines must be undergrounded within one year, or approved otherwise by the City of Renton Community and Economic Development Administrator or designee, from the first event triggering the requirement to underground the aerial lines. This decision to approve the exemption with conditions is subject to a fourteen (14) day appeal period from the date of this letter per RMC 4-8-110. Any appeals of the administrative decision must be filed with the City Clerk, along with the required appeal fee, by 5:00 pm, April 3, 2025. Appeals must be submitted electronically to the City Clerk at cityclerk@rentonwa.gov or delivered to City Hall 1st floor Lobby Hub Monday through Friday. The appeal fee, normally due at the time an appeal is submitted, will be collected at a future date if your appeal is submitted electronically. The appeal submitted in person may be paid on the first floor in our Finance Department. Appeals to the Hearing Examiner are governed by RMC 4-8-110 and additional information regarding the appeal process may be obtained from the City Clerk’s Office, cityclerk@rentonwa.gov.   Sincerely, Brianne Bannwarth, PE Development Engineering Director cc: Justin Johnson, Construction Engineering Manager Nathan Janders, Development Engineering Manager Scott Warlick, Engineering Specialist III Holly Powers, Engineering Specialist III Franchise Permits Enclosures: Site Plan COMCASTFDX - WAKVD08600 1X2 - WAKVD08500 1X2 (WAKVD05500 2X4)19167 110TH PL SE, RENTON, WA 98055, USAJB0002058033EQUIPMENT REPLACEMENT AT AERIAL AND UG LOCATIONS &PROPOSED AERIAL FIBER INSTALLATIONMFP25001055This permit is for Major construction work in the ROW and will be billed at an additional$158/HR for inspections. After hours and weekend work will be billed at $175/HR RDIGALERTFDX - WAKVD08600 1X2 - 19167 110TH PL SE RENTON, WA 98055, USA JB0002058033REVISIONSDATEDESCRIPTIONINITIAL COMCASTSHEETOFDATE:EXCEPT AS MAY BE OTHERWISE PROVIDED BY CONTRACT,THESE DRAWINGS AND SPECIFICATIONS SHALL REMAIN THEPROPERTY OF SEFNCO COMMUNICATION, INC. BOTH BEINGISSUED IN STRICT CONFIDENCE AND SHALL NOT BEREPRODUCED, COPIED, OR USED FOR ANY PURPOSEWITHOUT SPECIFIC WRITTEN PERMISSION.SITE NAME:SCALELOCATION ADDRESS: COMCAST JOB NUMBER: STAMPDRAWN BY:GAR02/13/2025WAKVD08500 1X2 (WAKVD05500 2X4)VICINITY MAPCONTACTSPG#SHEET INDEX1COVER SHEET2VICINITY MAP, CONTACTS & SHEET INDEX3GENERAL NOTES4LEGEND5-19SITE-PLAN20TYPICAL DETAILS20N/AN/AVICINITY MAP2PERMITTINGASHLEY KIEHN4610 TACOMA AVESUMNER, WA 98390PHONE: (253) 999-2271EMAIL: ASKIEHN@SEFNCO.COMCOMCASTSEFNCO OPEJOSHUA ASHLEY11308 SW 68TH PKWYTIGARD, OR, 97223PHONE: (503) 939-7931EMAIL: JOSHUA_ASHLEY@COMCAST.COMDOMINIC MINNITI4610 TACOMA AVESUMNER, WA 98390PHONE: (253) 736-4697EMAIL: DMINNITI@SEFNCO.COMDESCRIPTION OF WORKTOTALOVERLASH 48CT FIBER TO EXISTING STRAND (13 POLES)2321LFREPLACE EQUIPMENT AT AERIAL LOCATION (16)REPLACE EQUIPMENT AT UG LOCATION (8)UPGRADE EXISTING METAL PEDESTAL TO DOGHOUSE PEDESTAL (3)UPGRADE EXISTING TOWER PEDESTAL TO NEW DOGHOUSE PEDESTAL (1)TIE IN TO EXISTING SPLICE CASEEXISTING MID SPAN ATTACHMENTTOTAL:2321LFS3S4S5S6S7S14S15S2A A A A A19801 TALBOT RD S,RENTON, WA 98055CONSTRUCTION END19201 97TH AVE S,RENTON, WA 98055CONSTRUCTION BEGIN19167 110TH PL SE,RENTON, WA 98055CUTOVER BEGIN19901 97TH AVE S,RENTON, WA 98055CUTOVER ENDS1MFP25001055 RDIGALERTFDX - WAKVD08600 1X2 - 19167 110TH PL SE RENTON, WA 98055, USA JB0002058033REVISIONSDATEDESCRIPTIONINITIAL COMCASTSHEETOFDATE:EXCEPT AS MAY BE OTHERWISE PROVIDED BY CONTRACT,THESE DRAWINGS AND SPECIFICATIONS SHALL REMAIN THEPROPERTY OF SEFNCO COMMUNICATION, INC. BOTH BEINGISSUED IN STRICT CONFIDENCE AND SHALL NOT BEREPRODUCED, COPIED, OR USED FOR ANY PURPOSEWITHOUT SPECIFIC WRITTEN PERMISSION.SITE NAME:SCALELOCATION ADDRESS: COMCAST JOB NUMBER: STAMPDRAWN BY:GAR02/13/2025WAKVD08500 1X2 (WAKVD05500 2X4)20N/AN/AGENERAL NOTES3 THE LOCATIONS OF UTILITIES SHOWN ON THESE DRAWING ARE ONLY APPROXIMATE. SEFNCO HEREBY DISCLAIMS ANYRESPONSIBILITY TO THIRD PARTIES FOR THE ACCURACY OF THIS INFORMATION. PERSONS WORKING IN THE AREACOVERED BY THIS DRAWING MUST CONTACT THE STATEWIDE CALL-BEFORE-YOU-DIG SYSTEM TO ASCERTAIN THELOCATION OF UNDERGROUND UTILITIES PRIOR TO PERFORMING ANY EXCAVATION.1.ALL MATERIALS, WORKMANSHIP, AND CONSTRUCTION OF UTILITY IMPROVEMENTS SHALL MEET OR EXCEEDSITE WORK STANDARDS AND THE STANDARDS AND SPECIFICATIONS SET FORTH IN THE LOCAL JURISDICTIONREGULATIONS AND APPLICABLE STATE AND FEDERAL REGULATIONS. WHERE THERE IS CONFLICT BETWEENTHESE PLANS AND THE SPECIFICATIONS, OR ANY APPLICABLE STANDARDS, THE HIGHER QUALITY STANDARDSHALL APPLY. ALL WORK WITHIN PUBLIC R.O.W. OR EASEMENTS MAY REQUIRE INSPECTED AND APPROVED BYTHE LOCAL JURISDICTION INSPECTOR. INSPECTION SERVICES AND CONSTRUCTION CERTIFICATION TO BEPROVIDED BY DESIGNEE OF PROJECT SPONSOR/OWNER.2.THE CONTRACTOR IS SPECIFICALLY CAUTIONED THAT THE LOCATION AND/OR ELEVATION OF EXISTINGUTILITIES, AS SHOWN ON THESE PLANS, IS BASED ON RECORDS OF THE VARIOUS UTILITY COMPANIES AND,WHERE POSSIBLE, MEASUREMENTS TAKEN IN THE FIELD. THE INFORMATION IS NOT TO BE RELIED UPON ASBEING EXACT OR COMPLETE. THE CONTRACTOR MUST CALL THE LOCAL UTILITY LOCATION CENTER AT LEAST 48HOURS BEFORE ANY EXCAVATION TO REQUEST EXACT FIELD LOCATIONS OF EXISTING UTILITIES. THECONTRACTOR SHALL VERIFY PERTINENT LOCATIONS AND ELEVATIONS, ESPECIALLY AT THE CONNECTIONPOINTS AND AT POTENTIAL UTILITY CONFLICTS. IT SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR TORELOCATE ALL EXISTING UTILITIES THAT CONFLICT WITH THE PROPOSED IMPROVEMENTS SHOWN ON THESEPLANS.3.THE CONTRACTOR SHALL BE RESPONSIBLE FOR OBTAINING ALL NECESSARY PERMITS FROM ALL APPLICABLEAGENCIES. THE CONTRACTOR SHALL NOTIFY THE LOCAL JURISDICTION INSPECTOR AT LEAST 48 HOURS PRIORTO THE START OF ANY EARTH DISTURBING ACTIVITY OR CONSTRUCTION ON ANY AND ALL PUBLICIMPROVEMENTS IF REQUIRED.4.THE CONTRACTOR SHALL COORDINATE AND COOPERATE WITH THE LOCAL JURISDICTION AND ALL UTILITYCOMPANIES WITH REGARD TO RELOCATIONS OR ADJUSTMENTS OF EXISTING UTILITIES DURINGCONSTRUCTION, TO ASSURE THAT THE WORK IS ACCOMPLISHED IN A TIMELY FASHION, AND WITH A MINIMUMDISRUPTION OF SERVICE. THE CONTRACTOR SHALL BE RESPONSIBLE FOR CONTACTING ALL PARTIESAFFECTED BY ANY DISRUPTION OF ANY UTILITY SERVICE.5.THE CONTRACTOR SHALL HAVE ONE (1) SIGNED COPY OF THE APPROVED PLANS, ONE (1) COPY OF THEAPPROPRIATE STANDARDS AND SPECIFICATIONS, AND ONE (1) COPY OF ANY PERMITS AND EXTENSIONAGREEMENTS NEEDED FOR THE JOB ON-SITE AT ALL TIMES.6.THE CONTRACTOR SHALL BE RESPONSIBLE FOR ALL ASPECTS OF SAFETY INCLUDING, BUT NOT LIMITED TO:EXCAVATION, TRENCHING, SHORING, TRAFFIC CONTROL, AND SECURITY.7.IF, DURING THE CONSTRUCTION PROCESS, CONDITIONS ARE ENCOUNTERED BY THE CONTRACTOR, HISSUBCONTRACTORS, OR OTHER AFFECTED PARTIES WHICH COULD INDICATE A SITUATION THAT IS NOTIDENTIFIED IN THE PLANS OR SPECIFICATIONS, THE CONTRACTOR SHALL CONTACT THE ENGINEERIMMEDIATELY.8.ALL REFERENCES TO ANY PUBLISHED STANDARDS SHALL REFER TO THE LATEST REVISION OF SAID STANDARD,UNLESS SPECIFICALLY STATED OTHERWISE.9.FOR WORK AFFECTING PUBLIC ROADWAYS OR IF REQUIRED BY THE LOCAL JURISDICTION, THE CONTRACTORSHALL SUBMIT A TRAFFIC CONTROL AND PHASING PLAN IN ACCORDANCE WITH M.U.T.C.D. FOR APPROVAL.PRIOR TO ANY CONSTRUCTION ACTIVITIES WITHIN OR AFFECTING THE RIGHT-OF-WAY, THE CONTRACTOR SHALLBE RESPONSIBLE FOR PROVIDING ANY AND ALL TRAFFIC CONTROL DEVICES AS MAY BE REQUIRED BY SAIDPLANS. PRIOR TO INSTALLATION A PRECONSTRUCTION CONFERENCE SHALL BE HELD WITH LOCALJURISDICTION.10.THE CONTRACTOR IS RESPONSIBLE FOR PROVIDING ALL LABOR AND MATERIALS NECESSARY FOR THECOMPLETION OF THE INTENDED IMPROVEMENTS SHOWN ON THESE DRAWINGS OR DESIGNATED TO BEPROVIDED, INSTALLED, CONSTRUCTED, REMOVED OR RELOCATED UNLESS SPECIFICALLY NOTED OTHERWISE.11.PER AGENCY STANDARDS THE CONTRACTOR SHALL BE RESPONSIBLE FOR KEEPING ROADWAYS FREE ANDCLEAR OF ALL CONSTRUCTION DEBRIS AND DIRT TRACKED FROM THE SITE.12.THE CONTRACTOR SHALL BE RESPONSIBLE FOR RECORDING RECORD INFORMATION ON A SET OF RECORDDRAWINGS KEPT AT THE CONSTRUCTION SITE AND AVAILABLE TO THE LOCAL JURISDICTION INSPECTOR AT ALLTIMES.13.DIMENSIONS FOR LAYOUT AND CONSTRUCTION ARE NOT TO BE SCALED FROM ANY DRAWING. FOR ADDITIONALINFORMATION CONTACT THE ENGINEER FOR CLARIFICATION AND NOTE ON THE RECORD DRAWINGS.14.ALL EROSION AND SEDIMENT CONTROL (E.S.C.) MEASURES SHALL BE INSTALLED AT THE LIMITS OFCONSTRUCTION PRIOR TO GROUND DISTURBING ACTIVITY. ALL E.S.C. MEASURES SHALL BE MAINTAINED INGOOD REPAIR BY THE CONTRACTOR UNTIL SUCH TIME AS THE ENTIRE DISTURBED AREAS ARE STABILIZED WITHHARD SURFACE OR LANDSCAPING.15.ALL WORK WITHIN THE PUBLIC RIGHT-OF-WAY IS SUBJECT TO THE JURISDICTION OF THE LOCAL JURISDICTIONENGINEERING DEPARTMENT STANDARD DETAILS AND SPECIFICATIONS.16.ALL CONSTRUCTION OPERATIONS, INCLUDING THE WARMING UP, REPAIR, ARRIVAL, DEPARTURE OR RUNNINGOF TRUCKS, EARTH MOVING EQUIPMENT, CONSTRUCTION EQUIPMENT AND ANY OTHER ASSOCIATEDEQUIPMENT SHALL GENERALLY BE LIMITED TO THE TIME PERIOD APPROVED BY THE LOCAL JURISDICTION.17.CALL THE "CALL BEFORE YOU DIG" NUMBER 48HRS IN ADVANCE AT 1-800-424-5555 PRIOR TO DIGGING.RENTON1.ALL METHODS AND MATERIALS SPECIFICATION SHALL MEET ALL CITY OF RENTON STANDARDS.2.ALL RENTON STANDARD DETAIL DRAWINGS CAN BE FOUND AT THE FOLLOWING WEBSITE:https://edocs.rentonwa.gov/Documents/Browse.aspx?startid=13637033.ALL ASPHALT REPAIR TO BE DONE IN ACCORDANCE WITH RENTON STANDARDS. SEE RENTON STANDARD DETAIL -SECTION F 110.0-110.2.4.ALL SIDEWALK REPAIR TO BE DONE IN ACCORDANCE WITH RENTON STANDARDS. SEE RENTON STANDARD DETAIL- SECTION F 102.0.5.ALL CURB AND GUTTER REPAIR TO BE DONE IN ACCORDANCE WITH RENTON STANDARDS. SEE RENTONSTANDARD DETAIL - SECTION F 103.0.6.UTILITY LOCATIONS SHOWN ON THIS PLAN ARE BASED ON DOCUMENT RESEARCH AND FIELD EVALUATION. THEINFORMATION MAY NOT BE ACCURATE OR COMPLETE. IT IS THE CONTRACTOR'S RESPONSIBILITY TO PHYSICALLYLOCATE AND VERIFY LOCATION AND DEPTH OF ALL UTILITIES WITHIN THE CONSTRUCTION PATH. ALLINSTALLATIONS MUST COMPLY WITH MINIMUM HORIZONTAL AND VERTICAL CLEARANCES FROM UTILITIES.MFP25001055 RDIGALERTFDX - WAKVD08600 1X2 - 19167 110TH PL SE RENTON, WA 98055, USA JB0002058033REVISIONSDATEDESCRIPTIONINITIAL COMCASTSHEETOFDATE:EXCEPT AS MAY BE OTHERWISE PROVIDED BY CONTRACT,THESE DRAWINGS AND SPECIFICATIONS SHALL REMAIN THEPROPERTY OF SEFNCO COMMUNICATION, INC. BOTH BEINGISSUED IN STRICT CONFIDENCE AND SHALL NOT BEREPRODUCED, COPIED, OR USED FOR ANY PURPOSEWITHOUT SPECIFIC WRITTEN PERMISSION.SITE NAME:SCALELOCATION ADDRESS: COMCAST JOB NUMBER: STAMPDRAWN BY:GAR02/13/2025WAKVD08500 1X2 (WAKVD05500 2X4)20N/AN/ALEGEND 4LEGENDTELECOMMUNICATIONSANITARY SEWERGAS LINEWATERSTORM DRAINRECYCLED WATERPOWERPARCEL LINERIGHT OF WAYDITCH LINECENTER LINEEDGE OF PAVEMENTFACE OF CURBPROPERTY LINELIP OF GUTTERGUARDRAILSDSDWWSSSSGGTTLIPD/LEOPFOCRWRWBUILDING OUTLINEPFLFOG LINESIDEWALKSWSWTRENCHDIRECT BOREPROPOSED AERIAL STRAND PROOF/PULLPROPOSED OVERLASHMINOR ARTERIALCOLLECTOR ARTERIALINTERSTATE FREEWAYACCESS STREETPRINCIPAL ARTERIALBUILDINGR/WWARNING SIGN PLACEMENT (W/ PART #)TRAFFIC BARRELHYDRO-VAC TRENCHKEEPRIGHTREGULATORY SIGN (W/ PART #)LIMITSPEEDR2-125SPEED LIMIT CALLOUTSIGN PLACEMENT / DIRECTIONTRAFFIC CONEFLAGGER STATIONFLAGGER STATIONPATROL CARPOLICEOFFICERUNIFORMED POLICE OFFICERWORK VEHICLEFENCESTREET LIGHT HANDHOLETELECOM MANHOLETELECOM HANDHOLETELECOM CABINETTRAFFIC SIGNAL MANHOLETRAFFIC CABINETTRAFFIC SIGNAL PEDESTALSTREET LIGHT POLETRAFFIC SIGNAL HANDHOLECATV MANHOLECATV HANDHOLECATV PEDESTALTRAFFIC SIGNAL POLESTORM MANHOLEWATER VALVEWATER METERTELECOM PEDESTALSTORM INLETSTORM DRAIN UNKNOWN D?SISEWER VALVESSEWER VAULT SSSEWER UNKNOWN S?STORM DRAIN VAULT SDSEWER CLEANOUTSEWER MANHOLESCSEWER CATCH BASIN SSSTORM ACCESS POINTBASE LAYERSEXISTING UTILITIESROAD HATCH CLASSIFICATIONROW WORK LINETYPECOMCAST UNDERGROUND SYMBOLSEXISTING UTILITY SYMBOLSTRAFFIC CONTROL SYMBOLSSTORM CATCH BASIN SDTRAFFIC SIGNAL VAULTGAS METERTEST VALVEPEDESTAL UNK UTILITYFIRE HYDRANTGAS VALVEGAS TEST POINTGAS MANHOLEWATER PUMPGGGWATER AIR CONTROL VALVEWATER WELLWATER SAMPLING STATIONPOWER HANDHOLEPOWER MANHOLEPOWER CABINETPOWER VAULTPOWER PEDESTALPPOWER UNKNOWN PPPPPP?SIGN POSTCULVERTTRANSIT STOPBUSSTOPDRIVEWAY (FOC OR EOP)SDSSANCHORSIDEWALK ANCHOR & GUY(P) FIBER & COUNTF48(P) .625 COAX(P) .875 COAXCOMCAST AERIAL SYMBOLSPROPOSEDEXISTINGWRECKOUTPOLE W/O RISERRISERARMVERTICAL GROUNDSLACK SPANOVERHEAD GUYTANGENT ATTACHMENTDEAD-ENDDOUBLE DEAD-END(E) FIBER & COUNTF48(E) .625 COAX(E) .875 COAXSLSLTSTSTSTSCCCTTTTTSTS?PUMPFWELLTREE TRIMLIGHT/MEDIUM/HEAVYLMH//WRECKOUTVAULTSPLICE CASEMANHOLENode SymbolPEDESTALNode SymbolNode SymbolPAMINIBRIDGERTTTAATAPAMPLIFER POTHOLEBORE PIT / EXCAVATIONMMMPROPOSEDEXISTINGWRECKOUTNODENode SymbolABCDNode SymbolSTORAGE LOOPX'X'LIT INTERSECTIONFASFLASHING ARROWSEQUENTIAL ARROWSEQUENTIAL CHEVRONFLASHING DOUBLE ARROW(MERGE LEFT OR RIGHT)FLASHING CAUTIONORFLASHING DIAMOND CAUTIONARROWBOARD PLACEMENT (SEE BELOW)CHANNELIZING DEVICES / MIN DIMENSIONSNOTE(S):1.AN ARROWBOARD SHALL MEET THE MINIMUM SIZE, LEGIBILITYDISTANCE, NUMBER OF ELEMENTS AND OTHERSPECIFICATIONS SHOWN.2.LENGTH OF ARROW EQUALS 48", WIDTH OF ARROWHEADEQUALS 24".3.TYPE A, B AND C ARROW BOARDS SHALL HAVE SOLIDRECTANGULAR APPEARANCES. A TYPE D ARROW BOARDSHALL CONFORM TO THE SHAPE OF THE ARROW.ARROWBOARD TYPE MIN LEGIBILITYDISTANCEMIN SIZE MINIMUM# OFELEMENTSABCD48"×24"60"×30"96"×48"NONE12 MILE1 MILE34 MILE12 MILE121315125FT MIN4FT MIN8-12"45°TYPE 3 BARRICADE3FT MIN45°2FT MIN8-12"TYPE 1 BARRICADE3FT MIN8-12"2FT MIN45°TYPE 2 BARRICADE3-4"6"2"4"28'-36" MAXSPEED < 45MPHNIGHT AND/OR FREEWAYMORE THAN 36"4-6" TYPCONECONESPEED ≥ 45MPHDIRECTION INDICATOR BARRICADE12"8"36" MIN 24" MIN45°UNLIT INTERSECTIONDBTRENCHAVAC-TSPOTTER STATIONALL TRAFFIC CONTROL DEVICES / ANNOTATIONS PER MUTCDAMPLIFIER PICTURETAP PICTUREEquipmentMFP25001055 R/WR/W R/W R/WR/WR/W R/WR/WR/WR/W R/W R/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WFOCFOC FOC FOCFOCFOCFOC FOCFOCFOCFOCP P 110TH PL SE 110TH PL SE19167 1916611014191681912219167110TH PL SE110TH PL SESW SW SW SWSW SWRDIGALERTFDX - WAKVD08600 1X2 - 19167 110TH PL SE RENTON, WA 98055, USA JB0002058033REVISIONSDATEDESCRIPTIONINITIAL COMCASTSHEETOFDATE:EXCEPT AS MAY BE OTHERWISE PROVIDED BY CONTRACT,THESE DRAWINGS AND SPECIFICATIONS SHALL REMAIN THEPROPERTY OF SEFNCO COMMUNICATION, INC. BOTH BEINGISSUED IN STRICT CONFIDENCE AND SHALL NOT BEREPRODUCED, COPIED, OR USED FOR ANY PURPOSEWITHOUT SPECIFIC WRITTEN PERMISSION.SITE NAME:SCALELOCATION ADDRESS: COMCAST JOB NUMBER: STAMPDRAWN BY:GAR02/13/2025WAKVD08500 1X2 (WAKVD05500 2X4)20SITE PLAN - 1 5N1SITE PLAN CONSTRUCTION NOTES11UPGRADE EXISTING METAL PEDESTALTO DOGHOUSE PEDESTALTO DOGHOUSE PEDESTAL2REPLACE EQUIPMENT AT UG LOCATION22MFP25001055 R/WR/WR/WR/W POLE EOP EOP EOP EOP EOP EOP EOP EOP R/W R/W R/W R/W R/W R/W 19032190401903719015106TH AVE SE 106TH AVE SE R/W R/W R/W R/W R/W R/W R/W R/W R/W RDIGALERTFDX - WAKVD08600 1X2 - 19167 110TH PL SE RENTON, WA 98055, USA JB0002058033REVISIONSDATEDESCRIPTIONINITIAL COMCASTSHEETOFDATE:EXCEPT AS MAY BE OTHERWISE PROVIDED BY CONTRACT,THESE DRAWINGS AND SPECIFICATIONS SHALL REMAIN THEPROPERTY OF SEFNCO COMMUNICATION, INC. BOTH BEINGISSUED IN STRICT CONFIDENCE AND SHALL NOT BEREPRODUCED, COPIED, OR USED FOR ANY PURPOSEWITHOUT SPECIFIC WRITTEN PERMISSION.SITE NAME:SCALELOCATION ADDRESS: COMCAST JOB NUMBER: STAMPDRAWN BY:GAR02/13/2025WAKVD08500 1X2 (WAKVD05500 2X4)20SITE PLAN - 2 6N1SITE PLAN CONSTRUCTION NOTESREPLACE EQUIPMENT AT AERIALLOCATION1MFP25001055 R/W R/W R/W R/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/W R/W R/W R/WR/WR/WR/WR/WR/WR/W R/W R/W R/W R/WR/WR/WR/WPOLEFLFLFLFLFLFLFLFLFLFLEOPEOPEOPEOP FLFLFLFLFLFLFLEOP EOPFLFLFLFLFLFLFLFLFLFLEOPEOPEOP EOP EOP EOP EOPEOPEOP19207106071906019059SE 192ND STSE 192ND ST106TH AVE SE 106TH AVE SE 107TH AVE SE EOPEOPR/W R/W RDIGALERTFDX - WAKVD08600 1X2 - 19167 110TH PL SE RENTON, WA 98055, USA JB0002058033REVISIONSDATEDESCRIPTIONINITIAL COMCASTSHEETOFDATE:EXCEPT AS MAY BE OTHERWISE PROVIDED BY CONTRACT,THESE DRAWINGS AND SPECIFICATIONS SHALL REMAIN THEPROPERTY OF SEFNCO COMMUNICATION, INC. BOTH BEINGISSUED IN STRICT CONFIDENCE AND SHALL NOT BEREPRODUCED, COPIED, OR USED FOR ANY PURPOSEWITHOUT SPECIFIC WRITTEN PERMISSION.SITE NAME:SCALELOCATION ADDRESS: COMCAST JOB NUMBER: STAMPDRAWN BY:GAR02/13/2025WAKVD08500 1X2 (WAKVD05500 2X4)20SITE PLAN - 3 7N1SITE PLAN CONSTRUCTION NOTESREPLACE EQUIPMENT AT AERIALLOCATION1SE 192ND STMFP25001055 R/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WPOLEPOLEFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFOCR/WR/WR/WR/WR/WR/W R/WR/WFLR/WR/WR/WR/WR/WFOCFOCFOCFOCEOPEOPFOCFO C FOCFOC 104211042410420191291032610321SE 192ND STSE 192ND ST104TH PL SEEOP EOPEOPEOPSWSWSWSWSWSWSWSWSWSWSW SWSW RDIGALERTFDX - WAKVD08600 1X2 - 19167 110TH PL SE RENTON, WA 98055, USA JB0002058033REVISIONSDATEDESCRIPTIONINITIAL COMCASTSHEETOFDATE:EXCEPT AS MAY BE OTHERWISE PROVIDED BY CONTRACT,THESE DRAWINGS AND SPECIFICATIONS SHALL REMAIN THEPROPERTY OF SEFNCO COMMUNICATION, INC. BOTH BEINGISSUED IN STRICT CONFIDENCE AND SHALL NOT BEREPRODUCED, COPIED, OR USED FOR ANY PURPOSEWITHOUT SPECIFIC WRITTEN PERMISSION.SITE NAME:SCALELOCATION ADDRESS: COMCAST JOB NUMBER: STAMPDRAWN BY:GAR02/13/2025WAKVD08500 1X2 (WAKVD05500 2X4)20SITE PLAN - 4 8N1SITE PLAN CONSTRUCTION NOTESREPLACE EQUIPMENT AT AERIALLOCATION11MFP25001055 R/WR/W R/WR/WR/WR/WR/WR/WR/WR/WR/WR/W R/W R/WFLFLFLFLFOCFOCF O CFOC R/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WFOCFOCFOCFOCFOC FOCFOCPOLEPOLE PFLFLFLFLFLFLFLFLFLR/WR/WR/WR/WFOC FOC FOCFOCFOCFOCFOC FOC FOCFOC10159192181011310119101121921319202192081904510204SE 192ND STSE 192ND ST102ND AVE SE 102ND AVE SE SE 192ND PLSE 192ND PL101ST AVE SE(PRIVATE RD) 101ST PL SE (PRIVATE RD) 102ND AVE SE EOPEOPEOP FOC FOCFOCFOCFOCFOCFOCSWSWSW SW SWSWSWSWSWSWSWSWRDIGALERTFDX - WAKVD08600 1X2 - 19167 110TH PL SE RENTON, WA 98055, USA JB0002058033REVISIONSDATEDESCRIPTIONINITIAL COMCASTSHEETOFDATE:EXCEPT AS MAY BE OTHERWISE PROVIDED BY CONTRACT,THESE DRAWINGS AND SPECIFICATIONS SHALL REMAIN THEPROPERTY OF SEFNCO COMMUNICATION, INC. BOTH BEINGISSUED IN STRICT CONFIDENCE AND SHALL NOT BEREPRODUCED, COPIED, OR USED FOR ANY PURPOSEWITHOUT SPECIFIC WRITTEN PERMISSION.SITE NAME:SCALELOCATION ADDRESS: COMCAST JOB NUMBER: STAMPDRAWN BY:GAR02/13/2025WAKVD08500 1X2 (WAKVD05500 2X4)20SITE PLAN - 5 9NREPLACE EQUIPMENT AT UGLOCATION12SITE PLAN CONSTRUCTION NOTESREPLACE EQUIPMENT AT AERIALLOCATION112MFP25001055 R/W R/WR/WR/W R/W R/W R/WR/WR/WR/WR/WR/WR/W FLFLFLFLFLFLFLFLFLFL FL FL FLFLFLFLFLFLFLFLFLFLFLFLFL FL FL FLFLFLFLFLR/W R/W R/WR/WR/WR/WR/WPOLE PO L E1921119219192181921019203 10003750SE 1 9 2 N D S TS 55TH ST99TH PL S EOPEOPEOP EOPEOPEOP SE 192ND PLRDIGALERTFDX - WAKVD08600 1X2 - 19167 110TH PL SE RENTON, WA 98055, USA JB0002058033REVISIONSDATEDESCRIPTIONINITIAL COMCASTSHEETOFDATE:EXCEPT AS MAY BE OTHERWISE PROVIDED BY CONTRACT,THESE DRAWINGS AND SPECIFICATIONS SHALL REMAIN THEPROPERTY OF SEFNCO COMMUNICATION, INC. BOTH BEINGISSUED IN STRICT CONFIDENCE AND SHALL NOT BEREPRODUCED, COPIED, OR USED FOR ANY PURPOSEWITHOUT SPECIFIC WRITTEN PERMISSION.SITE NAME:SCALELOCATION ADDRESS: COMCAST JOB NUMBER: STAMPDRAWN BY:GAR02/13/2025WAKVD08500 1X2 (WAKVD05500 2X4)20SITE PLAN - 6 10N1SITE PLAN CONSTRUCTION NOTESREPLACE EQUIPMENT AT AERIALLOCATION11MFP25001055 R/WR/WR/WR/WR/WR/W R/ W R/ W R/WR/WR/WR/WR/WR/W R/WR/WR/WR/WR/WR/WR/WR/WR/W R/WFLFLFLFLFLFLFLFLFOCFOCFOCFOCFOCFOCR/WFOC FOCFOCR/W R/WR/WR/WEOPEOPEOPFLFLFLFLFLFL FL FL FL FLFLFLFLFLF LFL FL FL FL FLFLFLFLFLFLFLFLFLFLFLEOPEOPEOP POLEEOPEOPEOPEOP S 55T H S TS 55TH STS 55TH STS 55TH ST 98TH AVE S965119203520498EOPPR/W SWSWSWSWRDIGALERTFDX - WAKVD08600 1X2 - 19167 110TH PL SE RENTON, WA 98055, USA JB0002058033REVISIONSDATEDESCRIPTIONINITIAL COMCASTSHEETOFDATE:EXCEPT AS MAY BE OTHERWISE PROVIDED BY CONTRACT,THESE DRAWINGS AND SPECIFICATIONS SHALL REMAIN THEPROPERTY OF SEFNCO COMMUNICATION, INC. BOTH BEINGISSUED IN STRICT CONFIDENCE AND SHALL NOT BEREPRODUCED, COPIED, OR USED FOR ANY PURPOSEWITHOUT SPECIFIC WRITTEN PERMISSION.SITE NAME:SCALELOCATION ADDRESS: COMCAST JOB NUMBER: STAMPDRAWN BY:GAR02/13/2025WAKVD08500 1X2 (WAKVD05500 2X4)20SITE PLAN - 7 11N1SITE PLAN CONSTRUCTION NOTESREPLACE EQUIPMENT AT AERIALLOCATION12UPGRADE EXISTING TOWER PEDESTALTO NEW DOGHOUSE PEDESTAL3REPLACE EQUIPMENT AT UG LOCATION23MFP25001055 R/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WA A A A A A A A A A A A AAAAAAAAAAAP FOCFOCFOCFOC FOCR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WFL FLFLFL R/WR/WR/WR/WR/WR/WR/WR/WFOCFOCR/WR/WR/WR/WR/WR/WR/WR/W R/W R/W FLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFOCFOCR/WR/WR/WFOC FOC FLFLFLFLFLFLFLFLFLFLFL496S 55TH STS 192ND STTALBOT RD STALBOT RD S 97TH AVE S 1920019201960919225192241921819212EOP EOP EOP EOPEOPEOPEOPEOPEOPEOPEOPF O C FOC FOC FOC FOC124'108'9'200'1923154209533S 55TH ST (PRIVATE RD)POLE 1POLE 2POLE 3POLE 4 SWSWSWSW SW SW SWSWSWSWSWSW SW SWSW SW SW SW SW SW SWSW S 55TH STMATCH TO SITE PLAN - 9RDIGALERTFDX - WAKVD08600 1X2 - 19167 110TH PL SE RENTON, WA 98055, USA JB0002058033REVISIONSDATEDESCRIPTIONINITIAL COMCASTSHEETOFDATE:EXCEPT AS MAY BE OTHERWISE PROVIDED BY CONTRACT,THESE DRAWINGS AND SPECIFICATIONS SHALL REMAIN THEPROPERTY OF SEFNCO COMMUNICATION, INC. BOTH BEINGISSUED IN STRICT CONFIDENCE AND SHALL NOT BEREPRODUCED, COPIED, OR USED FOR ANY PURPOSEWITHOUT SPECIFIC WRITTEN PERMISSION.SITE NAME:SCALELOCATION ADDRESS: COMCAST JOB NUMBER: STAMPDRAWN BY:GAR02/13/2025WAKVD08500 1X2 (WAKVD05500 2X4)20SITE PLAN - 8 12N1TIE INTO EXISTING SPLICE CASE.1SITE PLAN CONSTRUCTION NOTES234EXISTING POLE (1-4).OVERLASH 48CT FIBER TO EXISTINGSTRAND.EXISTING MID SPAN ATTACHMENT.REPLACE EQUIPMENT AT UGLOCATION56REPLACE EQUIPMENT AT AERIALLOCATION232343253236MFP25001055 A A A A A A A AAAAA A A A A A A A PR/WR/WR/WR/WR/WR/WR/WR/WR/WR/W R/WR/WR/W R/ WFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFL R/WR/WR/WR/WR/WR/WR/WR/WR/W R/W R/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WFLFOCFOCFOCFOCFOCFOCFOCFOCTALBOT RD STALBOT RD S S 194TH STS 194TH ST9612961519221963396379640221'FOCFOCFOCFOCFOCFO C FOCEOP EOP EOP EOP169'EOP 97TH AVE S POLE 5POLE 6SWSWSWSW SWSWSWSWSWSWSWSWSWSWSW SW SW SW SW SW SW SW SW SWSWSWSWS WSW SWSWSW MATCH TO SITE PLAN -8MATCH TO SITE PLAN - 10RDIGALERTFDX - WAKVD08600 1X2 - 19167 110TH PL SE RENTON, WA 98055, USA JB0002058033REVISIONSDATEDESCRIPTIONINITIAL COMCASTSHEETOFDATE:EXCEPT AS MAY BE OTHERWISE PROVIDED BY CONTRACT,THESE DRAWINGS AND SPECIFICATIONS SHALL REMAIN THEPROPERTY OF SEFNCO COMMUNICATION, INC. BOTH BEINGISSUED IN STRICT CONFIDENCE AND SHALL NOT BEREPRODUCED, COPIED, OR USED FOR ANY PURPOSEWITHOUT SPECIFIC WRITTEN PERMISSION.SITE NAME:SCALELOCATION ADDRESS: COMCAST JOB NUMBER: STAMPDRAWN BY:GAR02/13/2025WAKVD08500 1X2 (WAKVD05500 2X4)20SITE PLAN - 9 13N12123141SITE PLAN CONSTRUCTION NOTES234OVERLASH 48CT FIBER TO EXISTINGSTRAND.EXISTING POLE (5-6).UPGRADE EXISTING METAL PEDESTALTO DOGHOUSE PEDESTALREPLACE EQUIPMENT AT AERIALLOCATIONMFP25001055 R/WR/WA A A A A A A A A A A A A A A A A A A A R/W R/W R/WR/WR/WR/WR/WR/WR/WR/WFL FL FL FL FLFLFLFLFLFLFLFLFL FL FL FL FLFLFLFLFLFLFLFLFLEOP EOP R/W R/W R/W R/W R/W R/W R/W TALBOT RD S TALBO T R D S 224' 196' 179'1941519418EOP EOP EOP EOP EOP EOP EOP POLE 7 POLE 8 RDIGALERTFDX - WAKVD08600 1X2 - 19167 110TH PL SE RENTON, WA 98055, USA JB0002058033REVISIONSDATEDESCRIPTIONINITIAL COMCASTSHEETOFDATE:EXCEPT AS MAY BE OTHERWISE PROVIDED BY CONTRACT,THESE DRAWINGS AND SPECIFICATIONS SHALL REMAIN THEPROPERTY OF SEFNCO COMMUNICATION, INC. BOTH BEINGISSUED IN STRICT CONFIDENCE AND SHALL NOT BEREPRODUCED, COPIED, OR USED FOR ANY PURPOSEWITHOUT SPECIFIC WRITTEN PERMISSION.SITE NAME:SCALELOCATION ADDRESS: COMCAST JOB NUMBER: STAMPDRAWN BY:GAR02/13/2025WAKVD08500 1X2 (WAKVD05500 2X4)20SITE PLAN - 10 14N12121MATCH TO SITE PLAN - 9MATCH TO SITE PLAN - 111SITE PLAN CONSTRUCTION NOTES2OVERLASH 48CT FIBER TO EXISTINGSTRAND.EXISTING POLE (7-8).MFP25001055 A A A A A A A A A A A A A A A A A A A A R/WR/WFLFLFLFLFLFLFLFLFLFLFLFLFLFLFOCR/W R/WR/WR/WR/WR/WR/WR/W R/W R/W R/W R/W EOP EOP EOP EOP EOP EOP EOP EOP R/W R/W R/W R/W R/W R/W R/W R/W R/W R/W 204' TALB O T R D S TALB O T R D S S 196TH PL19464194259497EOP FOC FOC FOCFOCFOCFOC FOC FOC FOC FOC POLE 9 POLE 1 0SW SW SWSWSW RDIGALERTFDX - WAKVD08600 1X2 - 19167 110TH PL SE RENTON, WA 98055, USA JB0002058033REVISIONSDATEDESCRIPTIONINITIAL COMCASTSHEETOFDATE:EXCEPT AS MAY BE OTHERWISE PROVIDED BY CONTRACT,THESE DRAWINGS AND SPECIFICATIONS SHALL REMAIN THEPROPERTY OF SEFNCO COMMUNICATION, INC. BOTH BEINGISSUED IN STRICT CONFIDENCE AND SHALL NOT BEREPRODUCED, COPIED, OR USED FOR ANY PURPOSEWITHOUT SPECIFIC WRITTEN PERMISSION.SITE NAME:SCALELOCATION ADDRESS: COMCAST JOB NUMBER: STAMPDRAWN BY:GAR02/13/2025WAKVD08500 1X2 (WAKVD05500 2X4)20SITE PLAN - 11 15N11SITE PLAN CONSTRUCTION NOTES2OVERLASH 48CT FIBER TO EXISTINGSTRAND.EXISTING POLE (9-10).3REPLACE EQUIPMENT AT AERIALLOCATION23121MATCH TO SITE PLAN - 10MATCH TO SITE PLAN - 12MFP25001055 A A A A A A A A A A A A A A A A A A A A P PFLFLFLFOC FOC FOC FOC FOC R/WR/WR/WR/WR/W R /WR/WR/WR/WFLFLFLFLFLFLFLFLFLEOP EOP R/W R/W R/W R/W R/W R/W R/W R/W R/W R/W R/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/W215'FOCFOCF O CS 196 PLR/W R/W949194851964319653TALBO T R D S TALBO T R D S S 198TH ST 19640196461970019652EOPEOPFOCFOCFOC233' 239' POLE 1 1 POLE 1 2 SW SW SW SWSWSWSWSWSWSW SWSWSWSW SW SWSWS 196 PLRDIGALERTFDX - WAKVD08600 1X2 - 19167 110TH PL SE RENTON, WA 98055, USA JB0002058033REVISIONSDATEDESCRIPTIONINITIAL COMCASTSHEETOFDATE:EXCEPT AS MAY BE OTHERWISE PROVIDED BY CONTRACT,THESE DRAWINGS AND SPECIFICATIONS SHALL REMAIN THEPROPERTY OF SEFNCO COMMUNICATION, INC. BOTH BEINGISSUED IN STRICT CONFIDENCE AND SHALL NOT BEREPRODUCED, COPIED, OR USED FOR ANY PURPOSEWITHOUT SPECIFIC WRITTEN PERMISSION.SITE NAME:SCALELOCATION ADDRESS: COMCAST JOB NUMBER: STAMPDRAWN BY:GAR02/13/2025WAKVD08500 1X2 (WAKVD05500 2X4)20SITE PLAN - 12 16N1MATCH TO SITE PLAN - 11MATCH TO SITE PLAN - 132121331SITE PLAN CONSTRUCTION NOTES2OVERLASH 48CT FIBER TO EXISTINGSTRAND.EXISTING POLE (11-12).3REPLACE EQUIPMENT AT UGLOCATIONMFP25001055 R/WR/WR/WR/WR/WR/WR/WR/W A A A A POLE FLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLEOP EOP R/W R/W R/W R/W R/W R/W R/W R/W R/W R/W R/WR/WR/WR/WR/WR/WR/WFLEOPEOPEOP19801952219809TALB O T R D S TALBO T R D S TALBOT RD S S 199TH ST19706198081981695139507EOPEOP EOPEOPFOCPOLE 1 3 SWSW RDIGALERTFDX - WAKVD08600 1X2 - 19167 110TH PL SE RENTON, WA 98055, USA JB0002058033REVISIONSDATEDESCRIPTIONINITIAL COMCASTSHEETOFDATE:EXCEPT AS MAY BE OTHERWISE PROVIDED BY CONTRACT,THESE DRAWINGS AND SPECIFICATIONS SHALL REMAIN THEPROPERTY OF SEFNCO COMMUNICATION, INC. BOTH BEINGISSUED IN STRICT CONFIDENCE AND SHALL NOT BEREPRODUCED, COPIED, OR USED FOR ANY PURPOSEWITHOUT SPECIFIC WRITTEN PERMISSION.SITE NAME:SCALELOCATION ADDRESS: COMCAST JOB NUMBER: STAMPDRAWN BY:GAR02/13/2025WAKVD08500 1X2 (WAKVD05500 2X4)20SITE PLAN - 13 17N1MATCH TO SITE PLAN - 122341SITE PLAN CONSTRUCTION NOTES2OVERLASH 48CT FIBER TO EXISTINGSTRAND.EXISTING POLE (13).3END OVERLASH AT EXISTINGSPLICE CASE.4REPLACE EQUIPMENT AT AERIALLOCATIONMFP25001055 R/W R/W R/W POLE FOC EOPR/W R/W R/W R/W R/W R/W R/W S 198TH ST92ND AVE S FOC9204920590599713EOPEOP EOPFOC FOC FOC FOCFOCRDIGALERTFDX - WAKVD08600 1X2 - 19167 110TH PL SE RENTON, WA 98055, USA JB0002058033REVISIONSDATEDESCRIPTIONINITIAL COMCASTSHEETOFDATE:EXCEPT AS MAY BE OTHERWISE PROVIDED BY CONTRACT,THESE DRAWINGS AND SPECIFICATIONS SHALL REMAIN THEPROPERTY OF SEFNCO COMMUNICATION, INC. BOTH BEINGISSUED IN STRICT CONFIDENCE AND SHALL NOT BEREPRODUCED, COPIED, OR USED FOR ANY PURPOSEWITHOUT SPECIFIC WRITTEN PERMISSION.SITE NAME:SCALELOCATION ADDRESS: COMCAST JOB NUMBER: STAMPDRAWN BY:GAR02/13/2025WAKVD08500 1X2 (WAKVD05500 2X4)20SITE PLAN - 14 18N1SITE PLAN CONSTRUCTION NOTESREPLACE EQUIPMENT AT AERIALLOCATION1MFP25001055 R/W R/W R/WR/WR/WR/WR/WR/W R/WR/WR/W POLEEOPEOPEOPEOPFOC FOC FOC97TH AVE SS 198TH PL (PRIVATE RD)97T H A V E S 199019615961619834FOC FOC FOC FOCFOCFOCFOC FOC FOCRDIGALERTFDX - WAKVD08600 1X2 - 19167 110TH PL SE RENTON, WA 98055, USA JB0002058033REVISIONSDATEDESCRIPTIONINITIAL COMCASTSHEETOFDATE:EXCEPT AS MAY BE OTHERWISE PROVIDED BY CONTRACT,THESE DRAWINGS AND SPECIFICATIONS SHALL REMAIN THEPROPERTY OF SEFNCO COMMUNICATION, INC. BOTH BEINGISSUED IN STRICT CONFIDENCE AND SHALL NOT BEREPRODUCED, COPIED, OR USED FOR ANY PURPOSEWITHOUT SPECIFIC WRITTEN PERMISSION.SITE NAME:SCALELOCATION ADDRESS: COMCAST JOB NUMBER: STAMPDRAWN BY:GAR02/13/2025WAKVD08500 1X2 (WAKVD05500 2X4)20SITE PLAN - 15 19N1SITE PLAN CONSTRUCTION NOTESREPLACE EQUIPMENT AT AERIALLOCATION1MFP25001055 20REVISIONSDATEDESCRIPTIONINITIALRDIGALERTFDX - WAKVD08600 1X2 - 19167 110TH PL SE RENTON, WA 98055, USA JB0002058033REVISIONSDATEDESCRIPTIONINITIAL COMCASTSHEETOFDATE:EXCEPT AS MAY BE OTHERWISE PROVIDED BY CONTRACT,THESE DRAWINGS AND SPECIFICATIONS SHALL REMAIN THEPROPERTY OF SEFNCO COMMUNICATION, INC. BOTH BEINGISSUED IN STRICT CONFIDENCE AND SHALL NOT BEREPRODUCED, COPIED, OR USED FOR ANY PURPOSEWITHOUT SPECIFIC WRITTEN PERMISSION.SITE NAME:SCALELOCATION ADDRESS: COMCAST JOB NUMBER: STAMPDRAWN BY:GAR02/13/2025WAKVD08500 1X2 (WAKVD05500 2X4)NTS20TYPICAL DETAILS AERIAL TYPICALSMFP25001055 DEPARTMENT OF COMMUNITY AND ECONOMIC DEVELOPMENT Conditions for Permit MFP25001055 Engineering 1 A traffic control plan must be separately submitted to the City, and no construction may take place until the City has approved a traffic control plan. 2 The new aerial fiber lines within the Project Reach must be converted to underground facilities in the future, at the Applicant’s cost, when any one of the following events occurs: (1) any other utilities are undergrounded within the Project Reach, (2) a joint use trench is proposed by a franchisee within the Project Reach, in which case the Applicant shall participate in the joint use trench installation for the purpose of undergrounding its aerial lines, or (3) a conduit is made available within the Project Reach that will accommodate the aerial lines. The new aerial lines must be undergrounded within one year, or approved otherwise by the City of Renton Community and Economic Development Administrator or designee, from the first event triggering the requirement to underground the aerial lines. 3 Any abandoned or unused lines within the Project Reach must be removed at the time that construction is taking place. 4 Any existing height violations within the Project Reach must be resolved at the time of construction. New aerial lines within the Project Reach must have a minimum vertical clearance of 15'-6". Page 1 of 1