No preview available
HomeMy WebLinkAboutMFP25000928.pdfDEPARTMENT OF COMMUNITY AND ECONOMIC DEVELOPMENT Major Franchise Permit: MFP25000928 IVR Number: 25000928 Permit Information Permit Name: Comcast Cable Franchise Permit Address/Location:02/25/2025Application Date:1565950470Parcel Number: 18905 112TH PL SE Permit Type:03/27/2025Issue Date:Franchise Permit Work Class:03/27/2026Expiration Date:Major Utility Job Number: JB0002058102Franchise Type:Cable Description: Comcast proposes to replace hardware at 10 aerial locations, replace hardware at 15 underground locations, proof and pull 48 ct fiber through existing conduit ~170LF, replace existing tower pedestal with new doghouse pedestal at 2 locations, replace existing metal doghouse pedestal with a new doghouse pedestals at 2 locations and replace existing doghouse pedestal with a node pedestal at 1 location. Contacts Name Address PhoneTypeBilling April Theoudele CHC Consulting 903 Calle Amanecer Ste 310 San Clemente, CA 92673 Applicant Jacob Neu ADP-Resources, LLC 163 SW Academy St. Dallas, OR 97338 Applicant Christie Walker Prince Telecom 13701 24th St E Building G, Building G Sumner, WA 98390 B: (253) 294-6548Applicant Leah Ihlenfeldt Cablecom LLC 1316 Bonneville Avenue Snohomish, WA 98290 B: (360) 670-4291Applicant Prime Electric Inc 3460 161ST Ave SE Bellevue, WA 98008 B: (425) 747-5200Applicant Ashley Kiehn Mastec Communications 4610 Tacoma Avenue Sumner, WA 98390 ApplicantX Danielle Hughes Prince Telecom LLC 13701 24th St E Bldg G Sumner, WA 98390 Applicant Joshua Day CCI SYSTEMS 105 Kent St Iron Mountain, MI 49801 Applicant Michele Moore Prince Telecom LLC 13701 24th St E, 24th St E Sumner, WA 98390 H: (206) 388-4316Applicant Gayle Berner Mastec North America Inc. H: (000) 000-0000 C: (253) 364-9363 Contact Joshua Ashley Comcast 410 Valley Ave NW, Suite 12 Bldg C Puyallup, WA 98371 B: (503) 939-7931Contact Laurie Dietz Comcast - Finance Questions 1701 John F. Kennedy Blvd. Philadelphia, PA 19103 H: (425) 741-5733Contact Rena Watts Comcast 1575 75th St SW, #200 Everett, WA 98203 B: (425) 977-9120 C: (425) 977-9120 Contact Andrew Parker comcast 410 Valley Ave NW Puyallup, WA 98371 B: (253) 864-4249Contact Permitting Department Cannon Construction LLC 406 Porter Way Milton, WA 98354 B: (253) 922-2787x286 Contact Tom Donnelly Comcast Business Communications 1701 Jfk Blvd, 32nd Floor Philadelphia, PA 19103 B: (215) 286-7347 C: (215) 286-7557 Contact Joshua Ashley Comcast 410 Valley Ave NW, Suite 12 Bldg C Puyallup, WA 98371 B: (503) 939-7931Emergency Contact BUYCO RUVEN G+MARIA SAMMARA 18905 112TH PL SE RENTON , WA 98055 Owner Amy Boldenow Comcast - Billing 1701 John F Kennedy BLVD John F. Kennedy Blvd Philadelphia, PA 19103 B: (425) 918-1140Specialized Billing Page 1 of 2THIS PERMIT AND PLANS MUST BE POSTED AT THE JOB SITE AT ALL TIMES Gayle Berner Gayle Berner 02/25/2025 Sefnco Communications Gayle Berner 253-364-9363 4610 TACOMA AVE SUMNER, WA 98390 x x JB0002058102 18905 112TH PL SE RENTON, WA 98055 03/31/2025 05/01/2025 9:00AM 5:30PM COMCAST PROPOSES TO REPLACE AERIAL / UNDERGROUND HARDWARE AT 25 LOCATIONS, PROOF AND PULL 48 CT FIBER ~170LF (2 EXISTING CONDUIT SPANS) AND REPLACE 5 EXISTING PEDESTALS WITH NEW PEDESTALS. Monday Friday 8:00am 3:00pm Scott Warlick CED 3/27/2025 MFP25000928 MFP25000928 MFP25000928 MFP25000928 MFP25000928 MFP25000928 MFP25000928 MFP25000928 MFP25000928 MFP25000928 MFP25000928 MFP25000928 MFP25000928 MFP25000928 MFP25000928 MFP25000928 MFP25000928 MFP25000928 MFP25000928 MFP25000928 MFP25000928 MFP25000928 MFP25000928 MFP25000928 MFP25000928 MFP25000928 MFP25000928 PROPOSED UNDERGROUND FIBER INSTALLATION AND EQUIPMENTREPLACEMENT AT AERIAL AND UNDERGROUND LOCATIONSCOMCASTREACTIVE FDX - WAKVD08C00 1X2 WAKVD08B00 1X2 - WAKVD08A00 1X2 (WAKVD03F00 2X4) - RF18905 112TH PL SE, RENTON, WA 98055, USAJB0002058102MFP25000928This permit is for Major construction work in the ROW and will be billed at an additional$158/HR for inspections. After hours and weekend work will be billed at $175/HRRESTORATION PER CITY OF RENTON STANDARDS RDIGALERTREACTIVE FDX - WAKVD08C00 1X2 WAKVD08B00 18905 112TH PL SE RENTON, WA 98055, USA JB0002058102REVISIONSDATEDESCRIPTIONINITIAL COMCASTSHEETOFDATE:EXCEPT AS MAY BE OTHERWISE PROVIDED BY CONTRACT,THESE DRAWINGS AND SPECIFICATIONS SHALL REMAIN THEPROPERTY OF SEFNCO COMMUNICATION, INC. BOTH BEINGISSUED IN STRICT CONFIDENCE AND SHALL NOT BEREPRODUCED, COPIED, OR USED FOR ANY PURPOSEWITHOUT SPECIFIC WRITTEN PERMISSION.SITE NAME:SCALELOCATION ADDRESS: COMCAST JOB NUMBER: STAMPDRAWN BY:AVR02/18/20251X2 - WAKVD08A00 1X2 (WAKVD03F00 2X4) - RF VICINITY MAPCONTACTSPG#SHEET INDEX1COVER SHEET2VICINITY MAP, CONTACTS & SHEET INDEX3GENERAL NOTES4LEGEND5-20SITE-PLAN20N/AN/ADESCRIPTION OF WORKTOTALPROOF/PULL THRU EXISTING CONDUIT WITH 48CT FIBER170LFREPLACE EQUIPMENT AT AERIAL LOCATION (10)REPLACE EQUIPMENT AT UG LOCATION (15)REPLACE EXISTING TOWER PED WITH NEW DOGHOUSE PED (2)REPLACE EXISTING METAL DOGHOUSE PED WITH NEW DOGHOUSE PED (2)REPLACE EXISTING DOGHOUSE PED WITH NEW NODE PED (1)TOTAL:170LFVICINITY MAP2PERMITTINGASHLEY KIEHN4610 TACOMA AVESUMNER, WA 98390PHONE: (253) 999-2271EMAIL: ASKIEHN@SEFNCO.COMCOMCASTSEFNCO OPEJOSHUA ASHLEY11308 SW 68TH PKWYTIGARD, OR, 97223PHONE: (503) 939-7931EMAIL: JOSHUA_ASHLEY@COMCAST.COMDOMINIC MINNITI4610 TACOMA AVESUMNER, WA 98390PHONE: (253) 736-4697EMAIL: DMINNITI@SEFNCO.COMS8S9S7S3S6S1S2S5S4S11S12S10S16S15S14S1318905 112TH PL SE,RENTON, WA 98055BEGIN19980 101ST AVE SE,RENTON, WA 98055END19105 123RD AVE SE,RENTON, WA 98058CONSTRUCTION END19125 123RD AVE SE,RENTON, WA 98058CONSTRUCTION CONTINUEFROM KENT CITY PERMITMFP25000928 RDIGALERTREACTIVE FDX - WAKVD08C00 1X2 WAKVD08B00 18905 112TH PL SE RENTON, WA 98055, USA JB0002058102REVISIONSDATEDESCRIPTIONINITIAL COMCASTSHEETOFDATE:EXCEPT AS MAY BE OTHERWISE PROVIDED BY CONTRACT,THESE DRAWINGS AND SPECIFICATIONS SHALL REMAIN THEPROPERTY OF SEFNCO COMMUNICATION, INC. BOTH BEINGISSUED IN STRICT CONFIDENCE AND SHALL NOT BEREPRODUCED, COPIED, OR USED FOR ANY PURPOSEWITHOUT SPECIFIC WRITTEN PERMISSION.SITE NAME:SCALELOCATION ADDRESS: COMCAST JOB NUMBER: STAMPDRAWN BY:AVR02/18/20251X2 - WAKVD08A00 1X2 (WAKVD03F00 2X4) - RF 20N/AN/AGENERAL NOTES3 THE LOCATIONS OF UTILITIES SHOWN ON THESE DRAWING ARE ONLY APPROXIMATE. SEFNCO HEREBY DISCLAIMS ANYRESPONSIBILITY TO THIRD PARTIES FOR THE ACCURACY OF THIS INFORMATION. PERSONS WORKING IN THE AREACOVERED BY THIS DRAWING MUST CONTACT THE STATEWIDE CALL-BEFORE-YOU-DIG SYSTEM TO ASCERTAIN THELOCATION OF UNDERGROUND UTILITIES PRIOR TO PERFORMING ANY EXCAVATION.1.ALL MATERIALS, WORKMANSHIP, AND CONSTRUCTION OF UTILITY IMPROVEMENTS SHALL MEET OR EXCEEDSITE WORK STANDARDS AND THE STANDARDS AND SPECIFICATIONS SET FORTH IN THE LOCAL JURISDICTIONREGULATIONS AND APPLICABLE STATE AND FEDERAL REGULATIONS. WHERE THERE IS CONFLICT BETWEENTHESE PLANS AND THE SPECIFICATIONS, OR ANY APPLICABLE STANDARDS, THE HIGHER QUALITY STANDARDSHALL APPLY. ALL WORK WITHIN PUBLIC R.O.W. OR EASEMENTS MAY REQUIRE INSPECTED AND APPROVED BYTHE LOCAL JURISDICTION INSPECTOR. INSPECTION SERVICES AND CONSTRUCTION CERTIFICATION TO BEPROVIDED BY DESIGNEE OF PROJECT SPONSOR/OWNER.2.THE CONTRACTOR IS SPECIFICALLY CAUTIONED THAT THE LOCATION AND/OR ELEVATION OF EXISTINGUTILITIES, AS SHOWN ON THESE PLANS, IS BASED ON RECORDS OF THE VARIOUS UTILITY COMPANIES AND,WHERE POSSIBLE, MEASUREMENTS TAKEN IN THE FIELD. THE INFORMATION IS NOT TO BE RELIED UPON ASBEING EXACT OR COMPLETE. THE CONTRACTOR MUST CALL THE LOCAL UTILITY LOCATION CENTER AT LEAST 48HOURS BEFORE ANY EXCAVATION TO REQUEST EXACT FIELD LOCATIONS OF EXISTING UTILITIES. THECONTRACTOR SHALL VERIFY PERTINENT LOCATIONS AND ELEVATIONS, ESPECIALLY AT THE CONNECTIONPOINTS AND AT POTENTIAL UTILITY CONFLICTS. IT SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR TORELOCATE ALL EXISTING UTILITIES THAT CONFLICT WITH THE PROPOSED IMPROVEMENTS SHOWN ON THESEPLANS.3.THE CONTRACTOR SHALL BE RESPONSIBLE FOR OBTAINING ALL NECESSARY PERMITS FROM ALL APPLICABLEAGENCIES. THE CONTRACTOR SHALL NOTIFY THE LOCAL JURISDICTION INSPECTOR AT LEAST 48 HOURS PRIORTO THE START OF ANY EARTH DISTURBING ACTIVITY OR CONSTRUCTION ON ANY AND ALL PUBLICIMPROVEMENTS IF REQUIRED.4.THE CONTRACTOR SHALL COORDINATE AND COOPERATE WITH THE LOCAL JURISDICTION AND ALL UTILITYCOMPANIES WITH REGARD TO RELOCATIONS OR ADJUSTMENTS OF EXISTING UTILITIES DURINGCONSTRUCTION, TO ASSURE THAT THE WORK IS ACCOMPLISHED IN A TIMELY FASHION, AND WITH A MINIMUMDISRUPTION OF SERVICE. THE CONTRACTOR SHALL BE RESPONSIBLE FOR CONTACTING ALL PARTIESAFFECTED BY ANY DISRUPTION OF ANY UTILITY SERVICE.5.THE CONTRACTOR SHALL HAVE ONE (1) SIGNED COPY OF THE APPROVED PLANS, ONE (1) COPY OF THEAPPROPRIATE STANDARDS AND SPECIFICATIONS, AND ONE (1) COPY OF ANY PERMITS AND EXTENSIONAGREEMENTS NEEDED FOR THE JOB ON-SITE AT ALL TIMES.6.THE CONTRACTOR SHALL BE RESPONSIBLE FOR ALL ASPECTS OF SAFETY INCLUDING, BUT NOT LIMITED TO:EXCAVATION, TRENCHING, SHORING, TRAFFIC CONTROL, AND SECURITY.7.IF, DURING THE CONSTRUCTION PROCESS, CONDITIONS ARE ENCOUNTERED BY THE CONTRACTOR, HISSUBCONTRACTORS, OR OTHER AFFECTED PARTIES WHICH COULD INDICATE A SITUATION THAT IS NOTIDENTIFIED IN THE PLANS OR SPECIFICATIONS, THE CONTRACTOR SHALL CONTACT THE ENGINEERIMMEDIATELY.8.ALL REFERENCES TO ANY PUBLISHED STANDARDS SHALL REFER TO THE LATEST REVISION OF SAID STANDARD,UNLESS SPECIFICALLY STATED OTHERWISE.9.FOR WORK AFFECTING PUBLIC ROADWAYS OR IF REQUIRED BY THE LOCAL JURISDICTION, THE CONTRACTORSHALL SUBMIT A TRAFFIC CONTROL AND PHASING PLAN IN ACCORDANCE WITH M.U.T.C.D. FOR APPROVAL.PRIOR TO ANY CONSTRUCTION ACTIVITIES WITHIN OR AFFECTING THE RIGHT-OF-WAY, THE CONTRACTOR SHALLBE RESPONSIBLE FOR PROVIDING ANY AND ALL TRAFFIC CONTROL DEVICES AS MAY BE REQUIRED BY SAIDPLANS. PRIOR TO INSTALLATION A PRECONSTRUCTION CONFERENCE SHALL BE HELD WITH LOCALJURISDICTION.10.THE CONTRACTOR IS RESPONSIBLE FOR PROVIDING ALL LABOR AND MATERIALS NECESSARY FOR THECOMPLETION OF THE INTENDED IMPROVEMENTS SHOWN ON THESE DRAWINGS OR DESIGNATED TO BEPROVIDED, INSTALLED, CONSTRUCTED, REMOVED OR RELOCATED UNLESS SPECIFICALLY NOTED OTHERWISE.11.PER AGENCY STANDARDS THE CONTRACTOR SHALL BE RESPONSIBLE FOR KEEPING ROADWAYS FREE ANDCLEAR OF ALL CONSTRUCTION DEBRIS AND DIRT TRACKED FROM THE SITE.12.THE CONTRACTOR SHALL BE RESPONSIBLE FOR RECORDING RECORD INFORMATION ON A SET OF RECORDDRAWINGS KEPT AT THE CONSTRUCTION SITE AND AVAILABLE TO THE LOCAL JURISDICTION INSPECTOR AT ALLTIMES.13.DIMENSIONS FOR LAYOUT AND CONSTRUCTION ARE NOT TO BE SCALED FROM ANY DRAWING. FOR ADDITIONALINFORMATION CONTACT THE ENGINEER FOR CLARIFICATION AND NOTE ON THE RECORD DRAWINGS.14.ALL EROSION AND SEDIMENT CONTROL (E.S.C.) MEASURES SHALL BE INSTALLED AT THE LIMITS OFCONSTRUCTION PRIOR TO GROUND DISTURBING ACTIVITY. ALL E.S.C. MEASURES SHALL BE MAINTAINED INGOOD REPAIR BY THE CONTRACTOR UNTIL SUCH TIME AS THE ENTIRE DISTURBED AREAS ARE STABILIZED WITHHARD SURFACE OR LANDSCAPING.15.ALL WORK WITHIN THE PUBLIC RIGHT-OF-WAY IS SUBJECT TO THE JURISDICTION OF THE LOCAL JURISDICTIONENGINEERING DEPARTMENT STANDARD DETAILS AND SPECIFICATIONS.16.ALL CONSTRUCTION OPERATIONS, INCLUDING THE WARMING UP, REPAIR, ARRIVAL, DEPARTURE OR RUNNINGOF TRUCKS, EARTH MOVING EQUIPMENT, CONSTRUCTION EQUIPMENT AND ANY OTHER ASSOCIATEDEQUIPMENT SHALL GENERALLY BE LIMITED TO THE TIME PERIOD APPROVED BY THE LOCAL JURISDICTION.17.CALL THE "CALL BEFORE YOU DIG" NUMBER 48HRS IN ADVANCE AT 1-800-424-5555 PRIOR TO DIGGING.RENTON1.ALL METHODS AND MATERIALS SPECIFICATION SHALL MEET ALL CITY OF RENTON STANDARDS.2.ALL RENTON STANDARD DETAIL DRAWINGS CAN BE FOUND AT THE FOLLOWING WEBSITE:https://edocs.rentonwa.gov/Documents/Browse.aspx?startid=13637033.ALL ASPHALT REPAIR TO BE DONE IN ACCORDANCE WITH RENTON STANDARDS. SEE RENTON STANDARD DETAIL -SECTION F 110.0-110.2.4.ALL SIDEWALK REPAIR TO BE DONE IN ACCORDANCE WITH RENTON STANDARDS. SEE RENTON STANDARD DETAIL- SECTION F 102.0.5.ALL CURB AND GUTTER REPAIR TO BE DONE IN ACCORDANCE WITH RENTON STANDARDS. SEE RENTONSTANDARD DETAIL - SECTION F 103.0.6.UTILITY LOCATIONS SHOWN ON THIS PLAN ARE BASED ON DOCUMENT RESEARCH AND FIELD EVALUATION. THEINFORMATION MAY NOT BE ACCURATE OR COMPLETE. IT IS THE CONTRACTOR'S RESPONSIBILITY TO PHYSICALLYLOCATE AND VERIFY LOCATION AND DEPTH OF ALL UTILITIES WITHIN THE CONSTRUCTION PATH. ALLINSTALLATIONS MUST COMPLY WITH MINIMUM HORIZONTAL AND VERTICAL CLEARANCES FROM UTILITIES.MFP25000928 RDIGALERTREACTIVE FDX - WAKVD08C00 1X2 WAKVD08B00 18905 112TH PL SE RENTON, WA 98055, USA JB0002058102REVISIONSDATEDESCRIPTIONINITIAL COMCASTSHEETOFDATE:EXCEPT AS MAY BE OTHERWISE PROVIDED BY CONTRACT,THESE DRAWINGS AND SPECIFICATIONS SHALL REMAIN THEPROPERTY OF SEFNCO COMMUNICATION, INC. BOTH BEINGISSUED IN STRICT CONFIDENCE AND SHALL NOT BEREPRODUCED, COPIED, OR USED FOR ANY PURPOSEWITHOUT SPECIFIC WRITTEN PERMISSION.SITE NAME:SCALELOCATION ADDRESS: COMCAST JOB NUMBER: STAMPDRAWN BY:AVR02/18/20251X2 - WAKVD08A00 1X2 (WAKVD03F00 2X4) - RF 20N/AN/ALEGEND 4LEGENDTELECOMMUNICATIONSANITARY SEWERGAS LINEWATERSTORM DRAINRECYCLED WATERPOWERPARCEL LINERIGHT OF WAYDITCH LINECENTER LINEEDGE OF PAVEMENTFACE OF CURBPROPERTY LINELIP OF GUTTERGUARDRAILSDSDWWSSSSGGTTLIPD/LEOPFOCRWRWBUILDING OUTLINEPFLFOG LINESIDEWALKSWSWTRENCHDIRECT BOREPROPOSED AERIAL STRAND PROOF/PULLPROPOSED OVERLASHMINOR ARTERIALCOLLECTOR ARTERIALINTERSTATE FREEWAYACCESS STREETPRINCIPAL ARTERIALBUILDINGR/WWARNING SIGN PLACEMENT (W/ PART #)TRAFFIC BARRELHYDRO-VAC TRENCHKEEPRIGHTREGULATORY SIGN (W/ PART #)LIMITSPEEDR2-125SPEED LIMIT CALLOUTSIGN PLACEMENT / DIRECTIONTRAFFIC CONEFLAGGER STATIONFLAGGER STATIONPATROL CARPOLICEOFFICERUNIFORMED POLICE OFFICERWORK VEHICLEFENCESTREET LIGHT HANDHOLETELECOM MANHOLETELECOM HANDHOLETELECOM CABINETTRAFFIC SIGNAL MANHOLETRAFFIC CABINETTRAFFIC SIGNAL PEDESTALSTREET LIGHT POLETRAFFIC SIGNAL HANDHOLECATV MANHOLECATV HANDHOLECATV PEDESTALTRAFFIC SIGNAL POLESTORM MANHOLEWATER VALVEWATER METERTELECOM PEDESTALSTORM INLETSTORM DRAIN UNKNOWN D?SISEWER VALVESSEWER VAULT SSSEWER UNKNOWN S?STORM DRAIN VAULT SDSEWER CLEANOUTSEWER MANHOLESCSEWER CATCH BASIN SSSTORM ACCESS POINTBASE LAYERSEXISTING UTILITIESROAD HATCH CLASSIFICATIONROW WORK LINETYPECOMCAST UNDERGROUND SYMBOLSEXISTING UTILITY SYMBOLSTRAFFIC CONTROL SYMBOLSSTORM CATCH BASIN SDTRAFFIC SIGNAL VAULTGAS METERTEST VALVEPEDESTAL UNK UTILITYFIRE HYDRANTGAS VALVEGAS TEST POINTGAS MANHOLEWATER PUMPGGGWATER AIR CONTROL VALVEWATER WELLWATER SAMPLING STATIONPOWER HANDHOLEPOWER MANHOLEPOWER CABINETPOWER VAULTPOWER PEDESTALPPOWER UNKNOWN PPPPPP?SIGN POSTCULVERTTRANSIT STOPBUSSTOPDRIVEWAY (FOC OR EOP)SDSSANCHORSIDEWALK ANCHOR & GUY(P) FIBER & COUNTF48(P) .625 COAX(P) .875 COAXCOMCAST AERIAL SYMBOLSPROPOSEDEXISTINGWRECKOUTPOLE W/O RISERRISERARMVERTICAL GROUNDSLACK SPANOVERHEAD GUYTANGENT ATTACHMENTDEAD-ENDDOUBLE DEAD-END(E) FIBER & COUNTF48(E) .625 COAX(E) .875 COAXSLSLTSTSTSTSCCCTTTTTSTS?PUMPFWELLTREE TRIMLIGHT/MEDIUM/HEAVYLMH//WRECKOUTVAULTSPLICE CASEMANHOLENode SymbolPEDESTALNode SymbolNode SymbolPAMINIBRIDGERTTTAATAPAMPLIFER POTHOLEBORE PIT / EXCAVATIONMMMPROPOSEDEXISTINGWRECKOUTNODENode SymbolABCDNode SymbolSTORAGE LOOPX'X'LIT INTERSECTIONFASFLASHING ARROWSEQUENTIAL ARROWSEQUENTIAL CHEVRONFLASHING DOUBLE ARROW(MERGE LEFT OR RIGHT)FLASHING CAUTIONORFLASHING DIAMOND CAUTIONARROWBOARD PLACEMENT (SEE BELOW)CHANNELIZING DEVICES / MIN DIMENSIONSNOTE(S):1.AN ARROWBOARD SHALL MEET THE MINIMUM SIZE, LEGIBILITYDISTANCE, NUMBER OF ELEMENTS AND OTHERSPECIFICATIONS SHOWN.2.LENGTH OF ARROW EQUALS 48", WIDTH OF ARROWHEADEQUALS 24".3.TYPE A, B AND C ARROW BOARDS SHALL HAVE SOLIDRECTANGULAR APPEARANCES. A TYPE D ARROW BOARDSHALL CONFORM TO THE SHAPE OF THE ARROW.ARROWBOARD TYPE MIN LEGIBILITYDISTANCEMIN SIZE MINIMUM# OFELEMENTSABCD48"×24"60"×30"96"×48"NONE12 MILE1 MILE34 MILE12 MILE121315125FT MIN4FT MIN8-12"45°TYPE 3 BARRICADE3FT MIN45°2FT MIN8-12"TYPE 1 BARRICADE3FT MIN8-12"2FT MIN45°TYPE 2 BARRICADE3-4"6"2"4"28'-36" MAXSPEED < 45MPHNIGHT AND/OR FREEWAYMORE THAN 36"4-6" TYPCONECONESPEED ≥ 45MPHDIRECTION INDICATOR BARRICADE12"8"36" MIN 24" MIN45°UNLIT INTERSECTIONDBTRENCHAVAC-TSPOTTER STATIONALL TRAFFIC CONTROL DEVICES / ANNOTATIONS PER MUTCDAMPLIFIER PICTURETAP PICTUREEquipmentMFP25000928 SWSWSWSWFOCSWSWFOCSWSWSWFOCSWFOCFOCFOCSWSWFOCSW SW FOCFOCFOC SE 188TH PL112 T H P L S E FOCFOCFOC 112TH PL SE SE 189TH CT1891711128189111890518813188071880311238112321122618820188121121911227112391124111237112291122311217R/W R/W R/W R/WR/WR/WR/WR/WR/WR/WR/WR/WR/W R/WR/WP RDIGALERTREACTIVE FDX - WAKVD08C00 1X2 WAKVD08B00 18905 112TH PL SE RENTON, WA 98055, USA JB0002058102REVISIONSDATEDESCRIPTIONINITIAL COMCASTSHEETOFDATE:EXCEPT AS MAY BE OTHERWISE PROVIDED BY CONTRACT,THESE DRAWINGS AND SPECIFICATIONS SHALL REMAIN THEPROPERTY OF SEFNCO COMMUNICATION, INC. BOTH BEINGISSUED IN STRICT CONFIDENCE AND SHALL NOT BEREPRODUCED, COPIED, OR USED FOR ANY PURPOSEWITHOUT SPECIFIC WRITTEN PERMISSION.SITE NAME:SCALELOCATION ADDRESS: COMCAST JOB NUMBER: STAMPDRAWN BY:AVR02/18/20251X2 - WAKVD08A00 1X2 (WAKVD03F00 2X4) - RF 20SITE PLAN - 1 5NREPLACE EQUIPMENT AT UGLOCATION1SITE PLAN CONSTRUCTION NOTESREPLACE EXISTING TOWER PED WITHNEW DOGHOUSE PED.212MFP25000928 FOC EOPEOPFOCSWFOCSWSWSW SW SW FOC SW SWFOCFOCSWSW FOC FOCSWSW FOCSWSW113TH WAY SE113TH WAY SE113TH WAY SE 1124011244112431890118829188211881111247188301882418816115TH LN SE (PRIVATE RD)SE 189TH LN(PRIVATE RD)EOPEOPR/W R/WR/WR/WR/WPRDIGALERTREACTIVE FDX - WAKVD08C00 1X2 WAKVD08B00 18905 112TH PL SE RENTON, WA 98055, USA JB0002058102REVISIONSDATEDESCRIPTIONINITIAL COMCASTSHEETOFDATE:EXCEPT AS MAY BE OTHERWISE PROVIDED BY CONTRACT,THESE DRAWINGS AND SPECIFICATIONS SHALL REMAIN THEPROPERTY OF SEFNCO COMMUNICATION, INC. BOTH BEINGISSUED IN STRICT CONFIDENCE AND SHALL NOT BEREPRODUCED, COPIED, OR USED FOR ANY PURPOSEWITHOUT SPECIFIC WRITTEN PERMISSION.SITE NAME:SCALELOCATION ADDRESS: COMCAST JOB NUMBER: STAMPDRAWN BY:AVR02/18/20251X2 - WAKVD08A00 1X2 (WAKVD03F00 2X4) - RF 20SITE PLAN - 2 6N1189091890818902REPLACE EQUIPMENT AT UGLOCATION1SITE PLAN CONSTRUCTION NOTESREPLACE EXISTING METAL DOGHOUSEPED WITH NEW DOGHOUSE PED22MFP25000928 FOC FOC FOC FOCFOCSWEOP EOPFOCFOC FOCFOCFOCSE 188TH STR/W R/W R/W R/W R/W R/W R/WR/WR/WR/WR/W R/W R/W R/W R/W R/WR/WR/W R/W R/W R/W PRDIGALERTREACTIVE FDX - WAKVD08C00 1X2 WAKVD08B00 18905 112TH PL SE RENTON, WA 98055, USA JB0002058102REVISIONSDATEDESCRIPTIONINITIAL COMCASTSHEETOFDATE:EXCEPT AS MAY BE OTHERWISE PROVIDED BY CONTRACT,THESE DRAWINGS AND SPECIFICATIONS SHALL REMAIN THEPROPERTY OF SEFNCO COMMUNICATION, INC. BOTH BEINGISSUED IN STRICT CONFIDENCE AND SHALL NOT BEREPRODUCED, COPIED, OR USED FOR ANY PURPOSEWITHOUT SPECIFIC WRITTEN PERMISSION.SITE NAME:SCALELOCATION ADDRESS: COMCAST JOB NUMBER: STAMPDRAWN BY:AVR02/18/20251X2 - WAKVD08A00 1X2 (WAKVD03F00 2X4) - RF 20SITE PLAN - 3 7N118814188081881318807188191882018802124TH AVE SE124TH AVE SE123RD PL SE123RD PL SE123RD PL SEREPLACE EQUIPMENT AT UGLOCATION1SITE PLAN CONSTRUCTION NOTESMFP25000928 SWFOCSWSWFOCSWFOCSWFOCSW SW SW FO C FOC FOC SW FOCFOCFOCSWSWSWSWSWFOCFOCFOCSWSWFOCSW112TH PL SE112TH PL SE1 1 3 T H W A Y S E SE 1 9 0 TH P L 113 T H W A Y S E 189281901019027190071105411201112031120511207112111121519029191131911719123110601911019104190301902419018R/W R/W R/WR/WR/ W R/WR/ W R/WR/WPP RDIGALERTREACTIVE FDX - WAKVD08C00 1X2 WAKVD08B00 18905 112TH PL SE RENTON, WA 98055, USA JB0002058102REVISIONSDATEDESCRIPTIONINITIAL COMCASTSHEETOFDATE:EXCEPT AS MAY BE OTHERWISE PROVIDED BY CONTRACT,THESE DRAWINGS AND SPECIFICATIONS SHALL REMAIN THEPROPERTY OF SEFNCO COMMUNICATION, INC. BOTH BEINGISSUED IN STRICT CONFIDENCE AND SHALL NOT BEREPRODUCED, COPIED, OR USED FOR ANY PURPOSEWITHOUT SPECIFIC WRITTEN PERMISSION.SITE NAME:SCALELOCATION ADDRESS: COMCAST JOB NUMBER: STAMPDRAWN BY:AVR02/18/20251X2 - WAKVD08A00 1X2 (WAKVD03F00 2X4) - RF 20SITE PLAN - 4 8N12REPLACE EQUIPMENT AT UGLOCATION1SITE PLAN CONSTRUCTION NOTESREPLACE EXISTING METAL DOGHOUSEPED WITH NEW DOGHOUSE PED22MFP25000928 EOPEOP EOP EOP EOP EOPSW FOCFOCFOCSWFOCFOC FOC FOCFOC FOC 113TH WAY SE 115TH LN SE (PRIVATE RD) SE 190TH LN(PRIVATE RD)EOPEOPEOPEOPEOPEOPR/WR/WR/WR/WR/WR/WR/WR/WR/W R/W R/W R/WR/WR/W114TH CT SE114TH CT SE RDIGALERTREACTIVE FDX - WAKVD08C00 1X2 WAKVD08B00 18905 112TH PL SE RENTON, WA 98055, USA JB0002058102REVISIONSDATEDESCRIPTIONINITIAL COMCASTSHEETOFDATE:EXCEPT AS MAY BE OTHERWISE PROVIDED BY CONTRACT,THESE DRAWINGS AND SPECIFICATIONS SHALL REMAIN THEPROPERTY OF SEFNCO COMMUNICATION, INC. BOTH BEINGISSUED IN STRICT CONFIDENCE AND SHALL NOT BEREPRODUCED, COPIED, OR USED FOR ANY PURPOSEWITHOUT SPECIFIC WRITTEN PERMISSION.SITE NAME:SCALELOCATION ADDRESS: COMCAST JOB NUMBER: STAMPDRAWN BY:AVR02/18/20251X2 - WAKVD08A00 1X2 (WAKVD03F00 2X4) - RF 20SITE PLAN - 5 9N218931189251900618932189261901419002189301892418918P1901719013REPLACE EQUIPMENT AT UGLOCATION1SITE PLAN CONSTRUCTION NOTESREPLACE EXISTING TOWER PED WITHNEW DOGHOUSE PED21MFP25000928 FOC FOC FOC FOC FOC FOCFOC EOPEOPFLFLFLFLFLFLFLFLFLFLFLFLFL FLSWSWSWSWSWSWSWSWSW SW FL FOC FOCFOC SWFOCFOC1171111705116751166911663116571165111652116581166211668116741894318937116101161618938189441170811714117TH LN SE SE 189TH PLSE 189TH PL SE 189TH PLSE 189TH LN(PRIVATE RD)116TH AVE SE116TH AVE SE EOP EOPEOPR/WR/WR/W R/W R/W R/W R/W R/W R/W R/W R/WR/WR/W R/WR/WR/WR/WR/W R/W R/WR/WR/WR/WR/WR/WR/WR/WPPOLE RDIGALERTREACTIVE FDX - WAKVD08C00 1X2 WAKVD08B00 18905 112TH PL SE RENTON, WA 98055, USA JB0002058102REVISIONSDATEDESCRIPTIONINITIAL COMCASTSHEETOFDATE:EXCEPT AS MAY BE OTHERWISE PROVIDED BY CONTRACT,THESE DRAWINGS AND SPECIFICATIONS SHALL REMAIN THEPROPERTY OF SEFNCO COMMUNICATION, INC. BOTH BEINGISSUED IN STRICT CONFIDENCE AND SHALL NOT BEREPRODUCED, COPIED, OR USED FOR ANY PURPOSEWITHOUT SPECIFIC WRITTEN PERMISSION.SITE NAME:SCALELOCATION ADDRESS: COMCAST JOB NUMBER: STAMPDRAWN BY:AVR02/18/20251X2 - WAKVD08A00 1X2 (WAKVD03F00 2X4) - RF 20SITE PLAN - 6 10NREPLACE EQUIPMENT AT UGLOCATION12SITE PLAN CONSTRUCTION NOTESREPLACE EQUIPMENT AT AERIALLOCATION11164511639116331162711621116152MFP25000928 SWSWSWFO C FOC S W S W SW SWSWSW SW FOCEOPFOCFOCFO C FO C SWSW 123RD PL SE123RD PL SE124TH AVE SE124TH AVE SESE 1 9 1 S T S T 123RD AVE SE190251902919019FOCFOC SW FOC123RD CT SE R/W R/W R/W R/WR/WR/WR/WR/WR/WR/WR/WR/WR/ W R/W R/WR/WR/WR/WR/ W R/W R/W R/WR/W SE 1 9 1 S T S T PPPPRDIGALERTREACTIVE FDX - WAKVD08C00 1X2 WAKVD08B00 18905 112TH PL SE RENTON, WA 98055, USA JB0002058102REVISIONSDATEDESCRIPTIONINITIAL COMCASTSHEETOFDATE:EXCEPT AS MAY BE OTHERWISE PROVIDED BY CONTRACT,THESE DRAWINGS AND SPECIFICATIONS SHALL REMAIN THEPROPERTY OF SEFNCO COMMUNICATION, INC. BOTH BEINGISSUED IN STRICT CONFIDENCE AND SHALL NOT BEREPRODUCED, COPIED, OR USED FOR ANY PURPOSEWITHOUT SPECIFIC WRITTEN PERMISSION.SITE NAME:SCALELOCATION ADDRESS: COMCAST JOB NUMBER: STAMPDRAWN BY:AVR02/18/20251X2 - WAKVD08A00 1X2 (WAKVD03F00 2X4) - RF 20SITE PLAN - 7 11N1SITE PLAN CONSTRUCTION NOTES11230312309190481904219036123RD AVE SE1905919105REPLACE EQUIPMENT AT UGLOCATION111P MFP25000928 FOCF O CFOC FOCFOCFOCFOCFOCFOCFOCFOCSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWEOPEOPEOPEOPEOPEOPEOPEOPFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFOCSWSWSWSWSW SWSWSWSWSWSWSWSWSWSW19139SE 192ND STSE 192ND STSE 192ND ST120TH AVE SE 120TH AVE SESE 191ST PL120TH CT SE 120201201419162FOCR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/W R/W R/W R/W R/W R/W R/WR/WR/WR/WR/W R/W R/WR/WR/WR/ W R/W R/WR/WR/WR/WR/WR/WPRDIGALERTREACTIVE FDX - WAKVD08C00 1X2 WAKVD08B00 18905 112TH PL SE RENTON, WA 98055, USA JB0002058102REVISIONSDATEDESCRIPTIONINITIAL COMCASTSHEETOFDATE:EXCEPT AS MAY BE OTHERWISE PROVIDED BY CONTRACT,THESE DRAWINGS AND SPECIFICATIONS SHALL REMAIN THEPROPERTY OF SEFNCO COMMUNICATION, INC. BOTH BEINGISSUED IN STRICT CONFIDENCE AND SHALL NOT BEREPRODUCED, COPIED, OR USED FOR ANY PURPOSEWITHOUT SPECIFIC WRITTEN PERMISSION.SITE NAME:SCALELOCATION ADDRESS: COMCAST JOB NUMBER: STAMPDRAWN BY:AVR02/18/20251X2 - WAKVD08A00 1X2 (WAKVD03F00 2X4) - RF 20SITE PLAN - 8 12N11SITE PLAN CONSTRUCTION NOTESREPLACE EQUIPMENT AT UGLOCATIONMFP25000928 FOC EOPEOPEOPEOPEOPEOPEOPEOPEOPEOPEOPEOPFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLSW 123RD AVE SE 19205SE 192ND STSE 192ND ST80'90'R/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/W R/W R/W PP PRDIGALERTREACTIVE FDX - WAKVD08C00 1X2 WAKVD08B00 18905 112TH PL SE RENTON, WA 98055, USA JB0002058102REVISIONSDATEDESCRIPTIONINITIAL COMCASTSHEETOFDATE:EXCEPT AS MAY BE OTHERWISE PROVIDED BY CONTRACT,THESE DRAWINGS AND SPECIFICATIONS SHALL REMAIN THEPROPERTY OF SEFNCO COMMUNICATION, INC. BOTH BEINGISSUED IN STRICT CONFIDENCE AND SHALL NOT BEREPRODUCED, COPIED, OR USED FOR ANY PURPOSEWITHOUT SPECIFIC WRITTEN PERMISSION.SITE NAME:SCALELOCATION ADDRESS: COMCAST JOB NUMBER: STAMPDRAWN BY:AVR02/18/20251X2 - WAKVD08A00 1X2 (WAKVD03F00 2X4) - RF 20SITE PLAN - 9 13NEXISTING PEDESTAL12SITE PLAN CONSTRUCTION NOTESPROOF/PULL THRU EXISTINGCONDUIT WITH 48CT FIBER1CONTINUE THE DESIGN FROM KENT CITY PERMIT123RD AVE SE191251911519119191112REPLACE EXISTING DOGHOUSEPED WITH NEW NODE PED31319105END OF DESIGN445REPLACE EQUIPMENT AT UGLOCATION5MFP25000928 EOPEOPEOPEOPEOPEOPEOPEOPEOPEOPEOPEOPEOP19422 1942319411194151062519404106TH AVE SE 106TH AVE SE SE 194TH ST107TH AVE SE 107TH AVE SE R/W R/W R/W R/W R/WR/WR/WR/WR/WR/WR/WR/WR/W R/W R/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/W R/W R/W R/W R/W R/W R/W R/W R/W R/W R/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WPOLE RDIGALERTREACTIVE FDX - WAKVD08C00 1X2 WAKVD08B00 18905 112TH PL SE RENTON, WA 98055, USA JB0002058102REVISIONSDATEDESCRIPTIONINITIAL COMCASTSHEETOFDATE:EXCEPT AS MAY BE OTHERWISE PROVIDED BY CONTRACT,THESE DRAWINGS AND SPECIFICATIONS SHALL REMAIN THEPROPERTY OF SEFNCO COMMUNICATION, INC. BOTH BEINGISSUED IN STRICT CONFIDENCE AND SHALL NOT BEREPRODUCED, COPIED, OR USED FOR ANY PURPOSEWITHOUT SPECIFIC WRITTEN PERMISSION.SITE NAME:SCALELOCATION ADDRESS: COMCAST JOB NUMBER: STAMPDRAWN BY:AVR02/18/20251X2 - WAKVD08A00 1X2 (WAKVD03F00 2X4) - RF 20SITE PLAN - 10 14N1SITE PLAN CONSTRUCTION NOTESREPLACE EQUIPMENT AT AERIALLOCATION1MFP25000928 EOPEOP EOPEOPEOP1041210420104301044010448194051040510439SE 194TH PL104TH AVE SE SE 194TH PLR/WR/WR/WR/WR/WR/WR/WR/WR/W R/WPOLERDIGALERTREACTIVE FDX - WAKVD08C00 1X2 WAKVD08B00 18905 112TH PL SE RENTON, WA 98055, USA JB0002058102REVISIONSDATEDESCRIPTIONINITIAL COMCASTSHEETOFDATE:EXCEPT AS MAY BE OTHERWISE PROVIDED BY CONTRACT,THESE DRAWINGS AND SPECIFICATIONS SHALL REMAIN THEPROPERTY OF SEFNCO COMMUNICATION, INC. BOTH BEINGISSUED IN STRICT CONFIDENCE AND SHALL NOT BEREPRODUCED, COPIED, OR USED FOR ANY PURPOSEWITHOUT SPECIFIC WRITTEN PERMISSION.SITE NAME:SCALELOCATION ADDRESS: COMCAST JOB NUMBER: STAMPDRAWN BY:AVR02/18/20251X2 - WAKVD08A00 1X2 (WAKVD03F00 2X4) - RF 20SITE PLAN - 11 15N1SITE PLAN CONSTRUCTION NOTESREPLACE EQUIPMENT AT AERIALLOCATION1MFP25000928 EOPEOP EOPEOPEOPEOPEOP EOPEOPEOPEOPEOPEOPEOPEOP106091062110631107011952319515195051060210610106101070219512195061943010466107TH AVE SESE 196TH STSE 196TH ST106TH AVE SE SE 195TH ST106TH AVE SE POLEEOPEOPR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/W R/WR/WR/WR/WR/WR/WR/WR/WR/W R/W R/W R/W R/W R/W R/WR/WR/WR/WR/WR/WR/W R/WR/WR/WR/WR/WR/WR/WPOLE POLERDIGALERTREACTIVE FDX - WAKVD08C00 1X2 WAKVD08B00 18905 112TH PL SE RENTON, WA 98055, USA JB0002058102REVISIONSDATEDESCRIPTIONINITIAL COMCASTSHEETOFDATE:EXCEPT AS MAY BE OTHERWISE PROVIDED BY CONTRACT,THESE DRAWINGS AND SPECIFICATIONS SHALL REMAIN THEPROPERTY OF SEFNCO COMMUNICATION, INC. BOTH BEINGISSUED IN STRICT CONFIDENCE AND SHALL NOT BEREPRODUCED, COPIED, OR USED FOR ANY PURPOSEWITHOUT SPECIFIC WRITTEN PERMISSION.SITE NAME:SCALELOCATION ADDRESS: COMCAST JOB NUMBER: STAMPDRAWN BY:AVR02/18/20251X2 - WAKVD08A00 1X2 (WAKVD03F00 2X4) - RF 20SITE PLAN - 12 16N1SITE PLAN CONSTRUCTION NOTESREPLACE EQUIPMENT AT AERIALLOCATION111MFP25000928 EOP EOP EOP FOCFOCFOCFOCFOCFOCPOLEPOLE 196311964319651196611980119714106TH AVE SE 106TH AVE SE R/W R/W R/W R/W R/W R/W R/W R/W R/WR/WR/WR/WR/WR/WR/WR/WR/WRDIGALERTREACTIVE FDX - WAKVD08C00 1X2 WAKVD08B00 18905 112TH PL SE RENTON, WA 98055, USA JB0002058102REVISIONSDATEDESCRIPTIONINITIAL COMCASTSHEETOFDATE:EXCEPT AS MAY BE OTHERWISE PROVIDED BY CONTRACT,THESE DRAWINGS AND SPECIFICATIONS SHALL REMAIN THEPROPERTY OF SEFNCO COMMUNICATION, INC. BOTH BEINGISSUED IN STRICT CONFIDENCE AND SHALL NOT BEREPRODUCED, COPIED, OR USED FOR ANY PURPOSEWITHOUT SPECIFIC WRITTEN PERMISSION.SITE NAME:SCALELOCATION ADDRESS: COMCAST JOB NUMBER: STAMPDRAWN BY:AVR02/18/20251X2 - WAKVD08A00 1X2 (WAKVD03F00 2X4) - RF 20SITE PLAN - 13 17N1SITE PLAN CONSTRUCTION NOTESREPLACE EQUIPMENT AT AERIALLOCATION11MFP25000928 SW FOC FOC EOPSW FOC SW FOC SW EOP104TH AVE SE 104TH AVE SE 1966019804196541965919801R/W R/W R/W R/W R/W R/W R/W R/W R/WR/WR/WR/WR/WR/WR/WR/WPOLE RDIGALERTREACTIVE FDX - WAKVD08C00 1X2 WAKVD08B00 18905 112TH PL SE RENTON, WA 98055, USA JB0002058102REVISIONSDATEDESCRIPTIONINITIAL COMCASTSHEETOFDATE:EXCEPT AS MAY BE OTHERWISE PROVIDED BY CONTRACT,THESE DRAWINGS AND SPECIFICATIONS SHALL REMAIN THEPROPERTY OF SEFNCO COMMUNICATION, INC. BOTH BEINGISSUED IN STRICT CONFIDENCE AND SHALL NOT BEREPRODUCED, COPIED, OR USED FOR ANY PURPOSEWITHOUT SPECIFIC WRITTEN PERMISSION.SITE NAME:SCALELOCATION ADDRESS: COMCAST JOB NUMBER: STAMPDRAWN BY:AVR02/18/20251X2 - WAKVD08A00 1X2 (WAKVD03F00 2X4) - RF 20SITE PLAN - 14 18N1SITE PLAN CONSTRUCTION NOTESREPLACE EQUIPMENT AT AERIALLOCATION1MFP25000928 FOC EOP EOP FLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFOCSW SWSWSWSWEOPEOPEOPEOPEOPEOPEOPSW SWFOCEOP SWFOCEOP EOPEOPEOP104101984810424198511984519835198441983419850104TH AVE SE104TH AVE SE 105TH AVE SE 105TH AVE SESE 200TH STSE 200TH STPOLE EOPEOPEOPR/W R/W R/W R/W R/W R/W R/W R/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/W R/W R/W R/W R/W R/W R/W R/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WRDIGALERTREACTIVE FDX - WAKVD08C00 1X2 WAKVD08B00 18905 112TH PL SE RENTON, WA 98055, USA JB0002058102REVISIONSDATEDESCRIPTIONINITIAL COMCASTSHEETOFDATE:EXCEPT AS MAY BE OTHERWISE PROVIDED BY CONTRACT,THESE DRAWINGS AND SPECIFICATIONS SHALL REMAIN THEPROPERTY OF SEFNCO COMMUNICATION, INC. BOTH BEINGISSUED IN STRICT CONFIDENCE AND SHALL NOT BEREPRODUCED, COPIED, OR USED FOR ANY PURPOSEWITHOUT SPECIFIC WRITTEN PERMISSION.SITE NAME:SCALELOCATION ADDRESS: COMCAST JOB NUMBER: STAMPDRAWN BY:AVR02/18/20251X2 - WAKVD08A00 1X2 (WAKVD03F00 2X4) - RF 20SITE PLAN - 15 19N1SITE PLAN CONSTRUCTION NOTESREPLACE EQUIPMENT AT AERIALLOCATION1MFP25000928 FOCFOCFOCFOCFOCFOCFLFLFLFLFLFLFLFLFLFLFLFLFL FLFLFLFLFLFLFLFLFLFLFLFOCSWSWSWSWFOCFOCSW SWFOCFOCFOCSWSWFOCFOCFOCSWSWSWSWSWSW EOPFLFLFLFLFLFLFLFLEOPEOPSE 200TH STSE 200TH ST101ST AVE SE 101ST AVE SE101ST AVE SEEOPEOPSW R/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/W R/W R/W R/W R/W R/WR/WR/WR/WR/WR/WR/W R/W R/WR/WR/WR/WR/WR/WR/WR/WR/WPP RDIGALERTREACTIVE FDX - WAKVD08C00 1X2 WAKVD08B00 18905 112TH PL SE RENTON, WA 98055, USA JB0002058102REVISIONSDATEDESCRIPTIONINITIAL COMCASTSHEETOFDATE:EXCEPT AS MAY BE OTHERWISE PROVIDED BY CONTRACT,THESE DRAWINGS AND SPECIFICATIONS SHALL REMAIN THEPROPERTY OF SEFNCO COMMUNICATION, INC. BOTH BEINGISSUED IN STRICT CONFIDENCE AND SHALL NOT BEREPRODUCED, COPIED, OR USED FOR ANY PURPOSEWITHOUT SPECIFIC WRITTEN PERMISSION.SITE NAME:SCALELOCATION ADDRESS: COMCAST JOB NUMBER: STAMPDRAWN BY:AVR02/18/20251X2 - WAKVD08A00 1X2 (WAKVD03F00 2X4) - RF 20SITE PLAN - 16 20N110112199801997419968199621995619981199891REPLACE EQUIPMENT AT UGLOCATION1SITE PLAN CONSTRUCTION NOTESMFP25000928 DEPARTMENT OF COMMUNITY AND ECONOMIC DEVELOPMENT Major Franchise Permit: MFP25000928 General Conditions & Signature Permission is hereby given for the work described on this permit according to the conditions hereon and according to the approved plans and specifications pertaining thereto, subject to compliance with the Ordinance of the City of Renton. Ÿ This permit and plans must be posted at the job site at all times.Ÿ I hereby certify that no work is to be done except as described above and in approved plans, and that work is to conform to Renton Trench Restoration and Street Overlay Requirements. Ÿ Call 425.430.7203 or go to: https://permitting.rentonwa.gov one working day in advance to schedule an inspections and for ANY work in the Right of Way. Ÿ Call 8 1 1 to locate underground utilities at least two full business days prior to any excavation.Ÿ In accordance with RCW 19.122.033(4) the permit holder is required to contact (Williams Northwest Pipeline at 425.868.1010) (Olympic Pipeline at 425.235.7736) (Puget Sound Energy at 425.375.3397) to request a consultation with the transmission pipeline company prior to performing any construction or excavation activities. This requirement to consult with the transmission pipeline company is in addition to the requirement to Call before You Dig as required in RCW 19.122. Ÿ (Date)(Signature) Page 2 of 2THIS PERMIT AND PLANS MUST BE POSTED AT THE JOB SITE AT ALL TIMES