HomeMy WebLinkAboutR-434608C4
co
Nt
I
0
W
DocuSign Envelope ID: 6EECF5B6-602A-4E4A-B436-A317AA638878
2
2 MAX.
LEVEL BOTTOM MAX 1�
12' MIN.
f T MIN.
SWALE SPACING DEPENDS ON SLOPE GRADIENT
NOTES:
1. CONDITIONS OF USE
1.1. REQUIRED AT:
1.1.1. THE TOP OF ALL SLOPES IN EXCESS OF 3HAV AND WITH MORE THAN 20 FEET OF VERTICAL RELIEF.
1.1,2, AT INTERVALS ON ANY SLOPES THAT EXCEEDS THE DIMENSIONS SPECIFIED BELOW.
AVERAGE SLOPE
SLOPE PERCENT
FLOW PATH LENGTH
20H:1 V (OR LESS)
3.5%
300 FEET
(10 TO 20)H:1V
5-10%
2D0 FEET
(4 TO 10)H:1 V
10.25%
100 FEET
(2 TO 4)HAV
25-50%
50 FEET
2. DESIGN AND INSTALLATION SPECIFICATIONS
2.1. FOR SLOPES STEEPER THAN 2HA V WITH MORE THAN 10 FEET OF VERTICAL RELIEF, BENCHES MAY BE CONSTRUCTED OR CLOSER SPACED
INTERCEPTOR SWALES MAY BE USED. THE DESIRED MEASURE MUST BE DESIGNED BY AN ENGINEER TO EFFECTIVELY INTERCEPT THE HIGH VELOCITY
RUNOFF TO A SEDIMENT POND OR TRAP.
2.2. CONSTRUCTION TRAFFIC OVER TEMPORARY SWALES SHALL BE MINIMIZED.
3. MAINTENANCE STANDARDS
3.1. DAMAGE RESULTING FROM RUNOFF OR CONSTRUCTION ACTIVITY SHALL BE REPAIRED IMMEDIATELY.
3.2. IF THE FACILITIES DO NOT REGULARLY RETAIN STORM RUNOFF. THE CAPACITY AND/OR FREQUENCY OF THE SWALES SHALL BE INCREASED.
UNLESS OTHERWISE NOTED, DRAWING IS NOT TO SCALE (NTS)
STD. PLAN - 217.10
`R DEPARTMENT PUBLIC WORKS INTERCEPTOR SWALE PPR D GAZ 9/28/2018 I
—�
DATE
DocuSign Envelope ID: 6EECF5B6-602A-4E4A-B436-A317AA638878
:45 AN
NTS
--(: 5
Interceptor Swale
2"x2' 14 GAUGE WIRE, OR
EQUIVALENT, IF STANDARD
STRENGTH FABRIC USED
FILTER FABRIC °1
1
--I�------------I�--� I
6'MAX. I 12" MIN.
POST
SPACING MAY BE INCREASE I 4 x4' MIN. TRENCH
TO 8' IF WIRE BACKING IS USED I I I I
—J
BACKFILL TRENCH WITH NATIVE SOIL LJ
OR 3/4' TO 1-17 WASHED GRAVEL
2'x4' WOOD POSTS, STEEL FENCE POSTS, OR EQUIVALENT (TYP.)
NOTES:
1. CONDITIONS OF USE
SILT FENCE MAY BE USED DOWNSLOPE OF ALL DISTURBED AREAS.
1.2. SILT FENCE IS NOT INTENDED TO TREAT CONCENTRATED FLOWS, NOR IS IT INTENDED TO TREAT SUBSTANTIAL AMOUNTS OF OVERLAND FLOW. ANY CONCENTRATED
FLOW MUST BE CONVEYED THROUGH THE DRAINAGE SYSTEM TO A SEDIMENT TRAP OR POND.
2. DESIGN AND INSTALLATION SPECIFICATIONS
2.1. THE GEOTEXTILE USED MUST MEET THE STANDARD LISTED BELLOW. A COPY OF THE MANUFACTURERS FABRIC SPECIFICATIONS MUST BE AVAILABLE ON SITE.
AOS (ASTM D4751)
30-100 SIEVE SIZE (0.60-0.15mm) FOR SILT FILM
50-100 SIEVE SIZE (0.30-0.1 Smm) FOR OTHER FABRICS
WATER PERMITTIVITY (ASTM D4491)
0-02 SEC -'MINIMUM
GRAB TENSILE STRENGTH (ASTM D4632)
180 LBS. MIN. FOR EXTRA STRENGTH FABRIC
100 LBS. MIN. FOR STANDARD STRENGTH FABRIC
GRAB TENSILE ELONGATION (ASTM D4632)
30% MAX. (WOVEN)
ULTRAVIOLET RESISTANCE (ASTM D4355)
70%MIN.
2.2. STANDARD STRENGTH FABRIC REQUIRES WIRE BACKING TO INCREASE THE STRENGTH OF THE FENCE. WIRE BACKING OR CLOSER POST SPACING MAY BE REQUIRED
FOR EXTRA STRENGTH FABRIC IF FIELD PERFORMANCE WARRANTS A STRONGER FENCE.
2.3. WHERE THE FENCE IS INSTALLED. THE SLOPE SHALL NOT BE STEEPER THAN 2HAV
2.4. IF A TYPICAL SILT FENCE IS USED, THE STANDARD 4"X4• TRENCH MAY BE REDUCED AS LONG AS THE BOTTOM 81NCHES OF THE SILT FENCE FABRIC IS WELL BURIED AND
SECURE IN A TRENCH THAT STABILIZES THE FENCE AND DOES NOT ALLOW WATER TO BYPASS OR UNDERMINE THE SILT FENCE.
2.5. FILTER FABRIC FENCES SHALL BE INSTALLED ALONG CONTOURS WHENEVER POSSIBLE.
3. MAINTENANCE STANDARDS
3.1. ANY DAMAGE SHALL BE REPAIRED IMMEDIATELY
3.2. IF CONCENTRATED FLOWS ARE EVIDENT UPHILL OF THE FENCE, THEY MUST BE INTERCEPTED AND CONVEYED TO A SEDIMENT TRAP OR POND.
3.3. IT IS IMPORTANT TO CHECK THE UPHILL SIDE OF THE FENCE FOR SIGNS OF THE FENCE CLOGGING AND ACTING AS A BARRIER TO FLOW AND THEN CAUSING
CHANNELIZATION OF FLOWS PARALLEL TO THE FENCE. IF THIS OCCURS, REPLACE THE FENCE OR REMOVE THE TRAPPED SEDIMENT.
3.4. SEDIMENT MUST BE REMOVED WHEN SEDIMENT IS 61NCHES HIGH.
3.5. IF THE FILTER FABRIC (GEOTEXTILE) HAS DETERIORATED DUE TO ULTRAVIOLET BREAKDOWN. IT SHALL BE REPLACED.
UNLESS OTHERWISE NOTED. DRAWING IS NOT TO SCALE (NTS)
STD. PLAN - 214.00
♦�}� DEPARTMENT PUBLIC WORKS SILT FENCE GAZ 9/28/2018 1
�
var�w,n.,4...mea DATE
:45 An
NTS- -( 9
Silt Fence
RUNOFF WITH
SEDIMENT
5%
FILTERED RUNOFF
i
WATER LEVEL
6"=12" PERFORATE
PIPE AS NECESSARY
`TOP OF PIPE SHALL BE
/ 6" MIN ABOVE GRADE
PROVIDE SOLID COVER
DISCHARGE TO SEDIMENT
1 POND VIA TEMP FORCE MAIN
�777
0 0 °
0 0 °
0 0 °
0 0 °
0 0 °
0 0 °
0 0 0
0 0 °
0 0 0
0 0 0
0 0 0
0 0 0
0 0 0
y o 0
fo
C
0 0 o T
I
0 0 0 L]
PROVIDE 12" MIN
WASHED ROCK AROUND
PERIMETER OF PIPE
WRAP WITH PERMEABLE
FILTER FABRIC
24"-36" PVC OR HDPE PIPE
W/ 2" DIA WEEP HOLES OR
APPROVED EQUAL
WIRE TIES
SUMP PUMP AND MOTOR
CONCRETE BLOCKS
NTS
Temporary Sump and Pump
TREE PROTECTION ZONE (TPZ) FENCE DETAIL
PROTECTION MEASURES DURING CONSTRUCTION:
BULDINO gN810N
1. Chain link fencing is required around the drip line of APPROVED
trees required to be retained, or around required tree
protection tracts/easements.
2. The fence shall be a minimum of 6-feet high.
3. Steel posts shall be driven at a depth to ensure the fence
remains in an upright position for the duration of the
development.
4. Tree protection signage shall be placed at intervals of nomore than 20-feet along the entire fence. See link below
for signage specifications. S
S. Storage, fill, excavation, earth compaction, or dumping
of liquids or materials is prohibited in fenced area.
6. Utilities or impervious surface installation is prohibited REQUIRED 6 FOOT
SIGNAGE 1 CHAIN LINK
within the tree drip line. FENCE
7. Grade changes are prohibited within the tree drip line.
8. Removal of the existing vegetation within the drip line of
TREE
protected trees is prohibited. PROTECTION
9. All areas within the required fencing shall be covered SIGNAGE
evenlywith a minimum of 3-inches of bark mulch, except
in areas where mulch will adversely affect protected )
ground cover plants.
10. For protected trees subject to a land use decision, the
applicant shall retain an ISA certified arborist or ASCA UNDISTURBED
DRIVEN MAINTAIN VEGETATION
certified consultant to supervise fence installation, EXISTING WITH 3-INCHES
monitor tree health, and prune trees. STEEL POSTS MULCH
GRADE
Planning Division LINK TO REQUIRED �' 11,E
CITY,OF
Renton ® South Grady Way :...:
TREE PROTECTION
Rent r
Renton, WA 98057
425-430-7200 1 www.rentonwagov SIGNAGE:
NTS 10
Tree Protection Fence
460
4' VERTI
440
420
WIRE FENCE
TO STEEL POST
SURVEYED:
7'
w DESIGNED: JAJ
DRAWN:
DJD/AJJ
43667 CHECKED:
L ��APPROVED:
NO. REVISION BY DATE APPR JAJ
480 500
EXISTING GRADE
460 480 CUT SLOPE
4' VERTICAL CUT
BOE 469.50
440 460 -
SEE PAGE C314 FOR
DETENTION VAULT
D ETA I LS
420 I 440
EXCAVATION FOR AND CONSTRUCTION OF FUTURE
DETENTION SYSTEM INSTALLATION UNDER SEPARATE
CIVIL CONSTRUCTION PERMIT NO. C24005771
1"=20' 3
Section A
SCALE:
N/A
ONE INCH
AT FULL SCALE
IF NOT ONE INCH
SCALE ACCORDINGLY
TENSAR GS-1 SAFETY
FENCE OR EQUAL
GALVANIZED WIRE OR
OTHER APPROVED
MATERIAL
NTS 7
Clearing Limits Fence
VERTICAL: NAVE) 1988
HORIZONTAL: NAD 1983/1991
DATUM
CITY OF
RENTON
Planning/Building/Public Works Dept.
500
GRAVEL BASE 460
SOFTBALL DETENTION EXCAVATION SECTION
SCALE: 111 = 201
EXCAVATION FOR AND CONSTRUCTION OF FUTURE
DETENTION SYSTEM INSTALLATION UNDER SEPARATE
CIVIL CONSTRUCTION PERMIT NO. C24005771
1"=20' 4
Section B
500 500
EXISTING GRADE
460
SEEPAGE C315 FOR
DETENTION VAULT
DETAILS
440 - 440
MULTIPURPOSE DETENTION EXCAVATIONSECTION
SCALE- 1" = 20'
EXCAVATION FOR AND CONSTRUCTION OF FUTURE
DETENTION SYSTEM INSTALLATION UNDER SEPARATE
CIVIL CONSTRUCTION PERMIT NO. C24005771
1"L
Section C
IN COMPLIANCE WITH CITY OF RENTON STANDARDS
DEVELOPMENT ENGINEERING 77%
Michael Sippo 03/30/2025
HAZEN HIGH SCHOOL MODERNIZATION
TESC DETAILS
DATE:
03/20/2025
FIELDBOOK:
PAGE:
DRAWING NO:
C111
SHEET: OF:
8 OF 8
00
Lid
O
O
LO
N
A,
u
00
O
O
O
O
I
4
N
Ir
'i1
()
M
O
O
O
N
Q
J
R-434608