HomeMy WebLinkAboutS-432405m
0
J
z
z
N
3
0
04
a
0
z
04
N
U
zz
0
z
z
LEGEND lu v ��� h
EX. PROPERTY LINE —••—••—••—••— / / ��
I,�\-/
---__ PROPOSED PROPERTY LINE --- --- a I \X
V I .
I
SAWCUT-------------- VN
I \ i PROPERTY LINE
SANITARY SEWER PIPE —SS— c_5.0 \ PROPOSED DEDICATION LINE
72 CLEANOUT (TYPE PER PLAN) c-5.o c 5.0 0
I(L �
'SPEED LIMIT\ ► I
25 MPH'
/ \ I I I/
I TWO-WAY CLEANOUT TEE
IE=96.33
I--------------------------------------------------------------------------- I III
!
20+50 0
SS—SS—SS—SS—SS—SS—SS—SS—SS—SSSS—ss—ss- • 0SS—SS—SS—SS—SS—SS—SS SS —SS �"-_SS
r-----------------------------------/-------------------------------------------- - - - - - - - - - - - - - -
PRIVATE 6" PVC SDR 35 SANITARY SIDE SEWER SERVICE, SHOWN FOR REFERENCE ONLY
�I (TO BE INSTALLED UNDER SEPARATE CRWSD SIDE SEWER PERMIT)
—SD— —SD— SD
1
21+00 I
MISS ESSE
I � I
III
I
III
I 9p
I ,
I 11
I ,I
10 ,
PROPOSED SANITARY SEWER STUB PLAN (STA. 20+00.00 TO 21+17.88)
SCALE: 1" = 5'
20+00 21+00
1 1 1 1 1
110 T - — — — — — —
i Wei
LEI
95
20+0000 CO
Do O°
�o
wnH�yl�-o�
FO)/-A\ i -
3 , 112712 2
� 47 335
rn ��'o,� ��GI STV
m 6814 Greenwood Ave N T (206) 522-9510 �`SS10 L
W Seattle, WA 98103 WWW.PAcLAND.COM
J
W
INSTALL 6"
IE = 96.33
E 6" PVC SDR 35 SANITARY SIDE SEWER SERVICE, SHOWN FOR REFERENCE ONLY
INSTALLED UNDER SEPARATE CRWSD SIDE SEWER PERMIT)
rn �
STATION
�o
o�
PROPOSED SANITARY SEWER STUB PROFILE (STA. 20+00.00 TO 21+17.88)
SCALE: H: 1 "=5' V: 1 "=2.5'
lk"1 0
DE REVISIONS #1
DE REVISIONS #:
REVISION
PACLAND
1/8/2025
SURVEYED:
ZLN
PACLAND
1/27/2025
DESIGNED:
WL
DRAWN:
WL
CHECKED:
JAC
BY
DATE
AP P R
APPROVED:
SCALE:
AS SHOWN
ONE INCH
AT FULL SCALE
IF NOT ONE INCH
SCALE ACCORDINGLY
VERTICAL• NAVE) 1988
HORIZONTAL: NAD 1983/1991
DATU M
SS
_SW 1/4OFS237T23N, R 5 E
Lu
(n
W i
I
� � I
I
Q '
I
O I
1 I
I
N'
H
STA. 21 +17.88
CONNECT 6" SANITARY SEWER STUB TO EX. 8" SS MAIN
IE = 95.80
I
I
EX. 8" SA ITARY SEWER
will:
V
U)
Q I
i
PROPOSED DEDICATION LINE
(6' MINIMUM DEPTH OF SIDE SEWER AT PL)
PROPERTY LINE
EXISTING GRADE
I
I �
EX. POWER
IE = 103.12 ASS
I
I
I EX. 12" SD
IE = 101.81
15 LF 6" PVC SDR 35 @ 3.51 %
SCALE: 1" = 5'
0 2.5 5 10
ACEIDARRIVER
WATER 80 NEWER DISTRICT
21 +25
1
110
r 100
STA. 21+17.88
CONNECT 6" SANITARY SEWER STUB TO EX. 8" SS MAIN
IE = 95.80
Know what's below.
rw,rnwvmm rows �a,�,� Call before you dig.
CEDAR RIVER WA10 a SEWER DISTRICT
BY PACE ENGINEERS INC.
" 2 1/ L
SIGNAMftN TI fyo, DATE
SU&ECT TO:
WASHINGTON STATE DEPARTMT OF HEALTH APPROVAL
IONG COUNTY FIRE MARSHAL'S APPROVAL
CITY OF RENTON CIVIL CONSTRUCTION PMAT (C24004215)
APPROVAL
NEW LIFE CHURCH
15711 152N D AVE SE
SANITARY SEWER STUB
PLAN AND PROFILE
Q0
0
0
0
1-4
1�
Ln
N
0
0
N
U
0
0
0
0
N
Q
DATE:
1 /27/2025
LJ
FIELDBOOK:
PAGE:
DRAWING NO:
SS-1.0
w
SHEET: OF:
z