Loading...
HomeMy WebLinkAboutW-432405m • 1� U U 0 t2 z z N 3 0 04 a 0 z 04 N U F i z 0 z W 1 z z O C9 Z 2 vi W zz J GENERAL UTILITY NOTES WATER NOTES SANITARY SEWER NOTES SEE SHEET CV-1.1 FOR GENERAL UTILITY NOTES. SEE SHEET CV-1.1 FOR WATER NOTES. SEE SHEET CV-1.1 FOR SANITARY SEWER NOTES. I� P P �MATCH U�ISEE I III I SHEETl� �I UTILITY KEY NOTES WATER CONSTRUCTION KEY NOTES QA CONDUIT FOR TELECOM; SIZE, TYPE, AND QUANTITY PER SERVICE PROVIDER. © TELECOM VAULT; SIZE AND TYPE PER SERVICE PROVIDER. © NOT USED. QD CONDUIT FOR UNDERGROUND POWER; SIZE TYPE, AND QUANTITY PER SERVICE PROVIDER. QE ELECTRICAL VAULT; SIZE AND TYPE PER SERVICE PROVIDER. 6814 Greenwood Ave N Seattle, WA 98103 T (206) 522-9510 WWW.PAcLAND.COM AI0>��GI 1SSIONAL 01 INSTALL 8"' DI CL52 WATER LINE (RJ PIPE), MAIN EXTENSION. 0 INSTALL 6" DI CL52 WATER LINE (RJ PIPE). 0 INSTALL 1" I.P.S. HDPE DOMESTIC WATER LINE. 2 -7.1 2 ® 5/8" DOMESTIC WATER METER. c-7.1 0 1" DOMESTIC WATER SERVICE CONNECTION. c � 1 © FIRE HYDRANT. e G47. 07 FIRE DEPARTMENT CONNECTION (FDC), PRIVATE. ® DOMESTIC SERVICE REDUCED PRESSURE BACKFLOW ASSEMBLY (RPBA) 0 CONNECT TO EXISTING WATER MAIN. e e c-7.o c-7.1 10 4" FIRE SERVICE CONNECTION. 11 INSTALL 4" DI CL52 FIRE LINE (RJ PIPE). 12 4" FIRE DDCVA. @ 13 INSTALL BEND (SEE PROFILE FOR STATIONING AND ANGLE). 1 1 PERMIT REVISIONS #1 NO. I REVISION TBM-C RR SPIKE IN W. FACE OF UP ELEV=108.00 RIM 106.40 8" PVC IE 96.59 (IN S., OUT N.) SW1/4OFS237T23N, R 5 E LEGEND EX. PROPERTY LINE PROPOSED PROPERTY LINE PROPOSED WATER EASEMENT SAWCUT WATER PIPE TEE/BEND AND CONCRETE BLOCKING GATE VALVE FIRE HYDRANT FDC WATER METER BOX RPBA SANITARY SEWER PIPE CLEANOUT (TYPE PER PLAN) TELE. UTILITY LINE/CONDUIT UNDERGROUND POWER LINE/CONDUIT STORM PIPE STORM STRUCTURE ROOF DRAIN LEADER FOOTING DRAIN -------------- -w- g 0 SS- T UGP O 0 WATER & SEWER PLANS SUBMITTED SEPARATELY TO CEDAR RIVER WATER & SEWER DISTRICT UNDER DEVELOPER EXTENSION O O O t t c-7.0 2 N C-7.0 3 C-7.0 3 C-7.1 2 C-7.1 1 C-7.2 1 C-5.0 1 C-5.0 C-5.0 T) N O O N U Qkp SCALE: 1" = 20' 0 10 20 40 Know what's b@IOW. Call before you dig. R-432431 IN COMPLIANCE WITH CITY OF RENTON STANDARDS DEVELOPMENT ENGINEERING yqi 03/26/2025 DATE: PACLAND 1/27/2025 SURVEYED: SCALE: W ZLN As SHOWN �`�TNAVD1968 NEW LIFE CHURCH / / HORIZONTAL: NAD 1983/1991 1 27 2025 DESIGNED: U CITY OF 15711 152ND AVE SE FlELDBOOK: Li — DRAWN: RENTON PAGE:MB ONE INCH DATUM DRAWING NO: CHECKED: AT FULL SCALE Planning/Building/Public Works Dept. UTILITY PLAN C — 3 , 1 JAC IF NOT ONE INCH BY DATE AP P R APPROVED: SCALE ACCORDINGLY SHEET: OF: LJJ z