Loading...
HomeMy WebLinkAboutW-432409m • U U W z 6+45 115 t1I 110 z 0 Q LLJ LLJ M 5 z N 3 100 6+45 0 dd o w OR a o o z N U `1 Z O z w a' z z 0 FO)/-A\ Li � o / 0- \ _ I c 4„DT 4"DT I o P 1 I I — — UGP UG "M 6"M I I P p o A- IN, X p —p---p p — — — — — — — — — — — — — — — — — — O � w w V 12 ■ STA. 8+17.63 8.50' LT IF ' 8))T 1 - 6" FIRE HYDRANT ASSEMBLY I r I 6 14 7 1XPROPOSED 15 WATER EASEMENT TO CRWSD (TYP) I � I ' C L _ 2 3 I , 5 11 I I/ 13-7+00 — — — — — — — — — — — — — — — — — — — — ---7+50-------------------------8+00-----J 8+50 / w�w� �w�w�w wmmo�w�w�w�w�w�w�wmm*�ww wwww ww� /I / /---------— — — — — — — — — — — — — — — -----a------------------------------ — — — — — — — — — — — — — — — — — — — — — — — - ---- / I STA.8+17.63 !f 1 1 6" FIRE HYDRANT CONNECTION 10 ' V — /' / I STA. 8+21.31 ' W / ' a 1" WATER SERVICE CONNECTION 1 1 ' j oCL /Ri cn DT 6 �44 L �i--------- P P —P / p p p d — P P p P j P P P P— ¢? PROPOSED WATER LINE PLAN (STA. 6+50.00 TO 8+60.00) SCALE: 1" = 10' 7+00 8+00 8+65 1 1 1 1 I 1 1 1 115 EXISTING/PROPOSED GRADE STA. 6+48.28 1 1 - 8" 22.5' BEND (RJ) CONC. THRUST BLOCKING STA. 6+98.87 1 - 8" 45' BEND (RJ) _ CONC. THRUST BLOCKING 50 LF 8" D.I.P. EX. 12" SD / (RJ) IE = 104.35 m 6814 Greenwood Ave N T (206) 522-9510 z Seattle, WA 98103 WWW.PAcLAND.COM CM 0 T 2712 2 I STY, �S14 �`ssIONAL 7+00 EX. 2" POWER IE = 108.03 (ASSUMED) CONTRACTOR TO POTHOLE CROSSING IN ADVANCE TO ALLOW PROFILE ADJUSTMENTS AS NECESSARY STATION 118 LF 8" D.I.P. (RJ) STA. 8+17.63 1 - 8%6" TEE (FL) 1 - 8" GV (FLXRJ) - 8" ADAPTOR (FLXRJ) 1 - 6" GV (FLxRJ) CONC. THRUST BLOCKING 7 LF 6" D.I.P. (RJ) M1M 00 PROPOSED WATER LINE PROFILE (STA. 6+50.00 TO 8+60.00) SCALE: H: 1 "=10' V: 1 "=2.5' 1" SERVICE FOR 5/8" DOM. WATER METER 35 LF 8" D.I.P. (RJ) /N:I&EX:I:1 1 - 8%4" TEE (FL) 2 - 8" GV (FLXRJ) 1 - 4" GV (FLxRJ) CONC. THRUST BLOCKING 12 LF 4" D.I.P. (RJ) 110 EX. 12" SD 105 z IE = 104.05 0 85 LF 8" D.I.P. (RJ) MIN 8+65 CD of 0 1 DE REVISIONS #1 PACLAND 1/8/2025 SURVEYED: ZLN SCALE: AS SHOWN 2 DE REVISIONS #2 PACLAND 1/27/2025 DESIGNED: WL DRAWN: WLI ONE INCH IAT FULL SCALE IF NOT ONE INCH SCALE ACCORDINGLY CHECKED: JAC NO. REVISION BY DATE AP P R APPROVED: VERnCAL• NAVD 1988 HORIZONTAL: NAD 1983/1991 DATU M SCALE: 1" = 10' 0 5 10 20 ACIEIDARRIVER WATER 80 SEWER DISTRICT SW1/4OFS237T23N, R 5 E LEGEND EX. PROPERTY LINE PROPOSED PROPERTY LINE PROPOSED WATER EASEMENT SAWCUT WATER PIPE TEE/BEND AND CONCRETE BLOCKING GATE VALVE FIRE HYDRANT WATER METER BOX RPBA FDC PIV DDCVA UNDERGROUND POWER LINE/CONDUIT UGP WATER CONSTRUCTION KEY NOTES 10 INSTALL 8"' DI CL52 WATER LINE (RJ PIPE), MAIN EXTENSION. 20 INSTALL 6" DI CL52 WATER LINE (RJ PIPE). 30 INSTALL 1" I.P.S. HDPE DOMESTIC WATER LINE. 2 C-7.1 ® 5/8" DOMESTIC WATER METER. 0 1" DOMESTIC WATER SERVICE CONNECTION. © FIRE HYDRANT. 3 c-7.o �7 FIRE DEPARTMENT CONNECTION (FDC), PRIVATE. QDOMESTIC SERVICE REDUCED PRESSURE BACKFLOW ASSEMBLY (RPBA) 10 4" FIRE SERVICE CONNECTION. 11 INSTALL 4" DI CL52 FIRE LINE (RJ PIPE). 12 4" FIRE DDCVA. @ 13 INSTALL BEND (SEE PROFILE FOR STATIONING AND ANGLE). PIPE MATERIAL NOTE: RJ PIPE MUST BE NOTE: CONTRACTOR TO VERTICALLY DEFLECT "THRUST LOCK" BOLTLESS RESTRAINED PIPE WITHIN HALF OF MAXIMUM DEFLECTION PER BY PACIFIC STATES OR EQUAL. MANUFACTURER'S RECOMMENDATIONS. APPROVED FOR CONSTRUCTION CEDAR RIVER WATER & SEWER DISTRICT 13Y PACEENGIIIINEE11M. M SIGNATURE y. )r&9e fJIN, 4,09,� DATE SUBJECT TO: WASHINGTON STATE OEPARTIIIENT OF HEALTH APPROVAL IONG COUNTY FlIItE MARSHALS APPROVAL CITY OF RENTON CIVIL CONSTRUCTION PERNT (C24004215) APPROVAL NEW LIFE CHURCH 15711 152N D AVE SE WATER MAIN EXTENSION PLAN AND PROFILE Know what's below. Call before you dig. Q0 0 0 0 1-4 In N 0 0 N U 0 0 0 0 N Q DATE: 1 /27/2025 LLJ FIELDBOOK: PAGE: DRAWING NO: C-4.3 LLJSHEET: OF: z