Loading...
HomeMy WebLinkAboutR-432430m • W z 0 0 cl z z N U 3 0 N W W a 0 z 04 U W U z 0 z W z 0 x W a z J SEE NOTE 4, LIMIT OF PIPE ZONE PIPE ZONE BEDDING AND T BACKFILL, SEE NOTE 5 T SEE STANDARD PLANS 110.1, 110.2, AND 111 FOR PAVEMENT 6" RESTORATION REQUIREMENTS NTS SURFACE RESTORATION AS SPECIFIED IN CONTRACT DOCUMENTS 12" MIN. EXISTING PAVEMENT SURFACE O.D. FOUNDATION �i ///\ ' LEVEL 6" \ i\ \ 6" MIN. ,SEE NOTE 4 FOUNDATION MATERIAL, IF REQUIRED, SEE NOTE 6� \/ O NEAT LINE TRENCH O� 0� \ "CRUSHED SURFACING TOP COURSE" PER FLEXIBLE PIPE � WSDOT STD. SPEC S-03.9(3),COMPACTED / TO 95% OF MAXIMUM DENSITY j 1 \ GRAVEL BACKFILL FOR PIPE ZONE BEDDING (WSDOT 9-03.12(3)) \ cz O OR MAINTENANCE ROCK (WSDOT 9-03.9(4)) / "CRUSHED SURFACING TOP COURSE" PER \ WSDOT STD. SPEC 9-03.9(3), "BANK RUN FLEXIBLE PIPE NOTES: \ GRAVEL FOR TRENCH BACKFILL" PER p p WSDOT STD. SPEC 9-03.19, OR "GRAVEL / 1. PROVIDE UNIFORM SUPPORT UNDER BARRELS. BORROW" PER WSDOT STD. SPEC 9-03.14(1), COMPACTED TO 95% OF MAXIMUM DENSITY 2. HAND TAMP UNDER HAUNCHES. 3. DIRECTLY OVER PIPE, HAND TAMP ONLY. \ / 4. SEE STANDARD WSDOT/APWA SPECIFICATIONS SECTION 2-09.4 FOR \ TRENCH WIDTH. BENCH AS NEEDED FOR \/\ SHORING SYSTEM WHEN 5. PIPE ZONE BEDDING AND BACKFILL MATERIAL SHALL BE PLACED IN 6" DEPTH IS 4' OR GREATER LOOSE LAYERS AND COMPACTED TO 95% MAXIMUM DENSITY. \/ t � 6. EXCAVATE UNSTABLE MATERIAL DOWN TO FIRM SOIL AND REPLACE WITH PIPE I \ FOUNDATION MATERIAL CLASS A OR B PER STANDARD WSDOT/APWA SPECIFICATIONS SECTION 9-03.17. PIPE ZONE BEDDING AND BACKFILL i PER STD. PLANS 220.00 AND 220.10 PIPE TYPE MINIMUM COVER (FT) PUBLIC? PRIVATE? ALLOWED IN ZONE 1 OF THE APA? LINE CORRUGATED POLYETHYLENE PIPE (LCPE) 2.0 YES YES YES CORRUGATED POLYETHYLENE PIPE (CPE) - TRIPLE WALL 2.0 YES YES YES POLYVINYL CHLORIDE PIPE (PVC) 3.0 YES YES YES SOLID WALL HIGH DENSITY POLYETHYLENE PIPE (HDPE) 2.0 YES YES YES POLYPROPYLENE PIPE (PP) - DUAL WALL 2.0 YES YES YES SEE NOTE 1 �I t UNPAVED AREAS I PAVED AREAS I NOTES: 1. SEE WSDOT/APWA STANDARD SPECIFICATIONS SECTION 2-09.4 FOR MINIMUM DISTANCE MEASUREMENT OF TRENCH WIDTH. DIAMETER BETWEEN BARRELS 2. EXCAVATIONS OVER 4' DEEP SHALL COMPLY WITH THE SAFETY STANDARD 12" TO 24" 2" DESCRIBED IN CHAPTER 295-155 PART N OF THE WAC. 30" TO 96" DIAMETER / 3 3. MAXIMUM BACKFILL DEPTH ABOVE PIPE SHALL NOT BE EXCEEDED, AS 102" TO 180" 48" DETERMINED BY PIPE MANUFACTURER. 4. IN PAVED AREAS, IF PIPE HAS LESS THAN 3' OF COVER, USE "CRUSHED SURFACING TOP COURSE" FOR THE ENTIRE BACKFILL DEPTH ABOVE PIPE ZONE. 5. SEE CONSTRUCTION PLANS FOR SPECIFIC PROJECT REQUIREMENTS. UNLESS OTHERWISE NOTED, DRAWING IS NOT TO SCALE (NTS) UNLESS OTHERWISE NOTED, DRAWING 15 NOT TO SCALE (NTS) STD. PLAN - 220.10 STD. PLAN - 220.20 ,} PUBLIC WORKS PIPE ZONE BEDDING AND §�edby o PUBLIC WORKS TYPICAL TRENCH AND BACKFILL PER D 9/28/2018 1 DEPARTMENT COMPACTION - FLEXIBLE PIPE artin Pastucha 8/13/20 DEPARTMENT GAZ Martin P,,N ha 6@8f4.*,,9Q8 D DATE VAINOFPublic Works Administrator DATE PIPE TRENCH BEDDING AND BACKFILL DETAILS NTS CITY OF RENTON 6814 Greenwood Ave N T (206) 522-9510 Seattle, WA 98103 WWW.PAcLAND.COM A. a1/27/2 2 0 34375 �o�, �SSIONAL St E NO. (1) OPEN PICKHOL I­LAI hAUE(iUIHIU (2) 3/8.-16 SS SOCKET HEAD CAP SCREW (ALLENHEAD) W/WSHRS ON A 8" DIA BOLT CIRCLE 9" DIA -� 5/ " 4" 8-1/8" DIA 10-1/2" DIA 15" DIA PLAN VIEW FRAME SECTION CAST IRON FRAME AND PAVED AREA (TYP.) COVER, SEE NOTE 3 12^ EXTEND ICLEANOUTRISER 2" ABOVE DESIGN SIGNPPONDING ELEVATION OR PER PLAN - 4 a DESIGN PONDING ELEVATION 8" CLASS "B" ASPHALT, SEE NOTE 4 'xi = \! 4" COMPACTED SAND OR GRAVEL BACKFILL FOR DRAINS PER WSDOT 9-03.12(4) O CLEANOUT RISER, SEE NOTE 2 SOIL TIGHT 45' BEND WYE SOIL TIGHT COUPLER UNDERDRAIN, FOOTING DRAIN COLLECTOR, OR ROOF DRAIN COLLECTOR PIPE, SEE NOTE 1 r� }� TO OVERFLOW STRUCTURE OR STORM MAIN 8-13/16" DIA 5/8" COVER SECTION FERNCO GASKETED QUIK CAP OR SIMILAR 4"STREAMBED COBBLES PER WSDOT 9-03.11(2) =1 11-V I i-i I I=111EE111 1= I_„III_-1111111 j11 CLEANOUT RISER, 1` =11 SEE NOTE 2 11 F6_L ZE, ill El I I1_I I. Ell IIIIIIIIIIIIII IIIII -III-III-I CLEANOUT RISER LOCATED WITHIN BIORETENTION PONDING AREA MECHANICAL PLUG OR CONTINUED CONNECTION TYPICAL CLEANOUT CONFIGURATION 6 r%-rcc. 1. DIAMETER TO BE 6-INCHES MINIMUM PRIVATE, 8-INCHES MINIMUM PUBLIC. UNDERDRAIN PIPE PER STD. PLAN 262.10. 2. CLEANOUT RISER SHALL BE SAME MATERIAL AS CONNECTED UNDERDRAIN, FOOTING DRAIN COLLECTOR, OR ROOF DRAIN COLLECTOR PIPE. 3. FRAME AND COVER SHALL BE EJ PRODUCTS 3675Z1 PT AND 3675APT OR APPROVED EQUAL. COVER TO BE LOCKING WITH ALLEN HEAD BOLT, MARKED "STORM" OR "DRAIN". 4. FOR CLEANOUTS FULLY OR PARTIALLY WITHIN UNPAVED AREAS OUTSIDE OF BIORETENTION PONDING AREA, POUR 8" THICK, 2'x2' SQUARE CONCRETE COLLAR AROUND FRAME. CONCRETE COLLAR SHALL HAVE A MINIMUM COMPRESSIVE STRENGTH OF 3,000 PSI. GENERAL NOTES: SW1/4OFS237T23N, R 5 E Q0 0 0 0 1-4 LnL 1. CLEANOUTS FOR UNDERDRAIN, FOOTING DRAIN COLLECTOR, AND ROOF DRAIN COLLECTOR PIPES SHALL BE INSTALLED AT A MINIMUM OF EVERY 100 FEET, AT EVERY 90 DEGREE OR SECOND 45 DEGREE BEND, AT THE END OF EVERY COLLECTOR PIPE, AND AT EACH END OF AN UNDERDRAIN PIPE NOT CONNECTED TO AN OVERFLOW STRUCTURE. CLEANOUTS SHALL BE INSTALLED TO ALLOW FOR MAINTENANCE ACCESS TO ALL PIPES. 2. ALL FITTINGS SHALL BE SOIL TIGHT. 3. CLEANOUT RISER SHALL BE LOCATED OUTSIDE OF BIORETENTION PONDING WHERE POSSIBLE. 4. CLEANOUTS SHALL NOT BE LOCATED WITHIN THE STREET TRAVEL LANE, UNLESS OTHERWISE APPROVED BY THE CITY. UNLESS OTHERWISE NOTED, DRAWING IS NOT TO SCALE (NTS) Aoft STD. PLAN - 226.00 DR) PUBLIC WORKS ®R08tAhed by: DEPARTMENT STORM SYSTEM CLEANOUT 11,'=%t5W9WDartiin Pastucha 8/13/20 iftmipF ... DATE PERMIT REVISIONS #1 PACLAND 1/27/2025 ZLN 8Wm AS SHOWN WL MB 11e JAC piNON REVISION BY DATE 1 APPR N� STORM DRAIN CLEANOUT DETAILS I m DATUM NTS CITY OF RENTON Planning/Building/Public Works Dept. CITY OF RENTON R-432438 IN COMPLIANCE WITH CITY OF RENTON STANDARDS DEVELOPMENT ENGINEERING _ yqi 03/18/2025 U U NEW LIFE CHURCH 1/27/2025 W 15711 152N D AVE SE pm __j STORM DRAINAGE DETAILS C-6.0 w ■M OR z