Press Alt + R to read the document text or Alt + P to download or print.
This document contains no pages.
HomeMy WebLinkAboutJ_Longacres Master Plan Proposed Code ModificationsProposed Text Changes (to be coordinated outside the scope of this application)
RMC #Title Full Text Proposed Modification Method of Modification
4-2-080.16.a Attached dwelling units may only be
allowed in conformance with the
following: Mass Transit Facilities.
At least fifty percent (50%) of the lot shall be located within one-quarter (1/4) mile (as
the crow flies) of at least one of the following:
i. Bus Stop: An official bus service stop that offers frequent service (see code for
details).
ii. Dedicated Park and Ride: A Park and Ride, as defined in RMC 4-11-160, Definitions
P.
iii. Commuter Rail: A passenger rail station.
Currently, Parcels 18, 20, and 21 are outside of the mass transit proximity zone, so can't
have attached dwelling units. We intent to propose in the forthcoming Development
Agreement (DA) that the project could allow parcel 18 to qualify.
N/A.
Note that this provision may
not be modified through the
PUD process (RMC 4-9-
150.B.3).
4-2-080.16.b Attached dwelling units may only be
allowed in conformance with the
following: Mixed Use Building.
Dwelling units shall be allowed only within a vertically mixed use building with ground
floor commercial designed and developed pursuant to RMC 4-4-150: Residential Mixed-
Use Development Standards. Commercial uses on the ground floor shall be limited to
retail sales, on-site services, eating and drinking establishments, taverns, daycares,
preschools, indoor recreational facilities, pet daycares, craft distilleries/small
wineries/micro-breweries with tasting rooms, and similar uses as determined by the
Administrator.
Allow residential-only buildings so long as they have some active uses on the ground
floor, including ground floor residential units accessed from the ROW, transparent
lobbies, amenity gym/recreation spaces, and/or amenity co-working spaces. This meets
the intent of the code without requiring an overproduction of ground floor-retail
throughout the district. Retail spaces will be more successful when concentrated at key
intersections, rather than spread out as a small amount within each building.
Text Change.
Note that this provision may
not be modified through the
PUD process (RMC 4-9-
150.B.3).
4-9-150.D.3.h Planned Urban Development
Regulations: Phasing
Each phase of the proposed development contains the required parking spaces, open
space, recreation spaces, landscaping and utilities necessary for creating and
sustaining a desirable and stable environment, so that each phase, together with
previous phases, can stand alone.
TBD. Would llike the ability to evaluate some things district wide as opposed to parcel by
parcel.
No code path.
4-9-150.E.2 Planned Urban Development
Regulations: Private Open Space.
Each residential unit in a planned urban development shall have usable private open
space (in addition to parking, storage space, lobbies, and corridors) for the exclusive use
of the occupants of that unit. Each ground floor unit, whether attached or detached,
shall have private open space contiguous to the unit. The private open space shall be
well demarcated and at least fifteen feet (15') in every dimension (decks on upper floors
can substitute for the required private open space). For dwelling units that are
exclusively upper story units, there shall be deck areas totaling at least sixty (60) square
feet in size with no dimension less than five feet (5'). For dwelling units located above the
sixth story, private open space may be provided by a shallow balcony accessed by a door
with at least fifty percent (50%) glazing; any required private open space not provided by
the balcony shall be added to the required common open space, pursuant to subsection
E1 of this Section. The minimum dimensional standards of this Section may be modified
through the planned urban development review process; provided, that the minimum
area requirement is maintained.
Waive this minimum requirement. Plentiful common open space will be provided
throughout the district, but requiring private balconies for every residential unit is a
substantial burden for new development. Some residential buildings may choose to
have balconies, but we propose that this not be required.
Text Change.
Note that this provision may
not be modified through the
PUD process (RMC 4-9-
150.B.3).
Proposed Interpretations of Existing Code
RMC #Title Full Text Proposed Modification Method of Modification
4-2-080.16.c Attached dwelling units may only be
allowed in conformance with the
following: Structured Parking
Required parking for the dwelling units shall be provided entirely within an attached
structured parking facility. If not provided within a structured parking garage, surface
parking lots serving commercial uses shall be located to the rear and/or side of the
building.
Allow parking for dwelling units to be provided within the district, but not necessarily
within the same building. In these cases, parking will be provided per the Off-Site Parking
regulations of RMC 4-4-080.E.2 and/or the Joint Use Parking Facility regulations of RMC
4-4-080.E.3, as appropriate.
City Interpretation.
Note that this provision may
not be modified through the
PUD process (RMC 4-9-
150.B.3).
4-2-120B Lot Coverage 65% of total lot area or 75% if parking is provided within the building or within a parking
garage.
Evaluate requirement on a district-wide basis including all parcels, not per lot. City Interpretation.
Per 4-2-120C.19, may be
modified with an approved
Master Plan.
4-2-120B Minimum Net Residential Density 75 DU/net acre Evaluate requirement as an average of all lots within the district that include residential.
Our understanding is that this requirement does not apply to lots where only
commercial development is proposed.
City Interpretation
4-2-120B Maximum Net Residential Density 150 DU/net acre. Up to 250 DU/net acre subject to conditional use permit approval.Evaluate requirement as an average of all lots within the district that include residential.
Our understanding is that this requirement does not apply to lots where only
commercial development is proposed.
City Interpretation
4-4-070.F.6 Parking Lots Parking lot landscaping required.TBD. We would like to discuss whether requirements apply to temporary parking lots. City Interpretation
4-9-150.E.1.b.i Planned Urban Development
Regulations: Mixed Use – Residential
Portions
Mixed use residential and attached housing developments of ten (10) or more dwelling
units shall provide a minimum area of common space or recreation area equal to fifty
(50) square feet per unit. The common space area shall be aggregated to provide usable
area(s) for residents. The location, layout, and proposed type of common space or
recreation area shall be subject to approval by the Hearing Examiner. The required
common open space shall be satisfied with one or more of the elements listed below.
The Hearing Examiner may require more than one of the following elements for
developments having more than one hundred (100) units.
(a) Courtyards, plazas, or multipurpose open spaces;
(b) Upper level common decks, patios, terraces, or roof gardens. Such spaces above the
street level must feature views or amenities that are unique to the site and provided as
an asset to the development;
(c) Pedestrian corridors dedicated to passive recreation and separate from the public
street system;
(d) Recreation facilities including, but not limited to: tennis/sports courts, swimming
pools, exercise areas, game rooms, or other similar facilities; or
(e) Children’s play spaces. (Ord. 5676, 12-3-2012)
Evaluate requirement on a district-wide basis, not evaluated per building or per lot.
Plentiful common open space will be provided throughout the district. The intent of the
master plan design is to aggregate common open space around the existing wetland and
pond, to provide a better open space experience than could be provided through a series
of discrete open spaces on each individual lot.
City Interpretation.
Note that this provision may
not be modified through the
PUD process (RMC 4-9-
150.B.3).
4-11-040.OO.1 Definition of "Attached Dwelling -
Flat"
Flat: A dwelling unit attached to one or multiple dwelling units by one or more common
roof(s), wall(s), or floor(s) within a building. Typically, the unit’s habitable area is
provided on a single level. Unit entrances are provided from a common internal corridor.
Allow multifamily ground-floor residential accessed from the street. We are proposing
ground floor units within larger apartment buildings, which would potentially be multiple
stories and accessed from the public ROW. These units would function like townhomes
and add activation and human scale to the pedestrian experience. Unit entrances would
likely not be provided from a common corridor, but we believe these should still be
permitted under the definition of "Attached Dwelling - Flat."
City Interpretation
Proposed Modifications per PUD Process
RMC #Title Full Text Proposed Modification Method of Modification
4-2-120B Setbacks - Minimum Front Yard:
Buildings Less Than 25' in Height
15'Waive required setbacks for commercial buildings of all heights, to match the
requirement for residential mixed use buildings. This will allow the district to provide
continuous street walls and an urban experience of commercial buildings common to
dense development.
Per 4-2-120C.19, may be
modified with an approved
Master Plan. May also be
modified through the PUD
(RMC 4-9-150.B.2.a).
4-2-120B Setbacks - Minimum Front Yard:
Buildings 25' to 80' in Height
20'Waive required setbacks for commercial buildings of all heights, to match the
requirement for residential mixed use buildings. This will allow the district to provide
continuous street walls and an urban experience of commercial buildings common to
dense development.
Per 4-2-120C.19, may be
modified with an approved
Master Plan. May also be
modified through the PUD
(RMC 4-9-150.B.2.a).
4-2-120B Setbacks - Minimum Front Yard:
Buildings Over 80' in Height
30'Waive required setbacks for commercial buildings of all heights, to match the
requirement for residential mixed use buildings. This will allow the district to provide
continuous street walls and an urban experience of commercial buildings common to
dense development.
Per 4-2-120C.19, may be
modified with an approved
Master Plan. May also be
modified through the PUD
(RMC 4-9-150.B.2.a).
4-2-120B Setbacks - Maximum Front Yard:
Residential Mixed Use Buildings
15'Waive the maximum front yard setback for residential mixed use buildings in order to
allow individual developments to provide public plazas or other public amenities where
appropriate.
Per 4-2-120C.19, may be
modified with an approved
Master Plan. May also be
modified through the PUD
(RMC 4-9-150.B.2.a).
4-2-120B Clear Vision Area In no case shall a structure over 42 in. in height intrude into the 20 ft. clear vision area
defined in RMC 4-11-030.
Allow structures to overhang the clear vision area above a height of 15'. This allows for
better floorplates and a more prominent urban corner, without compromising safety.
PUD (RMC 4-9-150.B.2.a).
4-2-120B Maximum Gross Floor Area of Any
Residential Use on a Site
Limited to 25% of the total gross floor area of all buildings on site. Waive requirement. The long-term vision for the site includes substantial new office
development and other non-residential uses, likely exceeding the residential area
proposed. However, due to current market conditions, it is not feasible to develop
commercial office in the near future. The intent of this district plan is to bring new
residential development to the existing office on the site, and to build out new
commercial as the site evolves and market conditions change.
PUD (RMC 4-9-150.B.2.a).
4-2-120B Upper Story Setbacks Residential mixed use buildings: buildings or portions of buildings that exceed one
hundred feet (100') in height shall include upper story setbacks as follows: The minimum
setback for a seventh (7th) story and succeeding stories shall be ten feet (10') minimum
from the preceding story, applicable to each story, or an equivalent standard that adds
interest and quality to the building.
Intent is to comply along primary pedestrian routes. We propose to waive this
requirement along the "West Access Road," since this is primarily a service street that is
meant to take traffic off of the "Esplanade."
PUD (RMC 4-9-150.B.2.a).
4-2-120B Roofline and Façade Modification Residential mixed use buildings: buildings shall provide vertical and horizontal
modulation of roof lines and facades of not less than two feet (2') at a minimum interval
of forty feet (40') per building face, or an equivalent standard that adds interest and
quality to the building.
N/A Would be at a later date when building designed.PUD (RMC 4-9-150.B.2.a).
4-3-100.6 Signage In addition to the City’s standard sign regulations, developments within Urban Design
Districts C and D are also subject to the additional sign restrictions found in RMC 4-4-
100G, urban design sign area regulations. Modifications to the standard requirements
found in RMC 4-4-100G are possible for those proposals that can comply with the
Design District intent and guidelines, as determined by the Administrator; for proposals
unable to meet the intent and guidelines a variance is required.
TBD. District signage is still being evaluated. PUD (RMC 4-9-150.B.2.a).
4-4-070.F.1 Street Frontage Landscaping
Required
Ten feet (10') of on-site landscaping is required along all public street frontages, with the
exception of areas for required walkways and driveways and those zones with building
setbacks less than ten feet (10'). In those cases, ten feet (10') of landscaping shall be
required where buildings are not located.
We are requesting a waiver for commercial building minimum setback requirements
(see above), which would similarly eliminate the need for landscaping along public
frontages. This will allow the district to provide continuous street walls and an urban
experience of commercial buildings common to dense development.
PUD (RMC 4-9-150.B.2.a).
4-4-080.F.6.c Fire Lane Standards: Identification i. Lanes shall be identified by a four inch (4") wide line and curb painted bright red. The
block letters shall state, “FIRE LANE – NO PARKING”, be eighteen inches (18") high,
painted white, located not less than one foot (1') from the curb face, at fifty foot (50')
intervals. (Ord. 4130, 2-15-1988)
ii. Signs shall be twelve inches by eighteen inches (12" x 18") and shall have letters and
background of contrasting colors, readily readable from at least a fifty foot (50')
distance. (Ord. 3988, 4-28-1966)
iii. Signs shall be spaced not further than fifty feet (50') apart nor shall they be placed
less than five feet (5'), or more than seven feet (7') from the ground. The installation and
use of fire lane signs will preclude the requirement for painting “FIRE LANE – NO
PARKING”, in the lane only. The area shall be identified by painting the curb red or in the
absence of a curb, a four inch (4") red line shall be used. (Ord. 4130, 2-15-1988)
TBD. Would like to discuss with the Fire Department how to allow fire access on some of
the mews while maintaining an inconspicuous pedestrian focus.
PUD (RMC 4-9-150.B.2.a).
4-4-080.F.6.d Fire Lane Standards: Surfacing and
Construction Requirements
Fire lanes shall be an all weather surface constructed of asphalt or concrete designed to
be capable of supporting a thirty (30) ton fire apparatus vehicle.
Would like to discuss with the Fire Department whether grasscrete or permeable pavers
could be used to allow fire access on some of the mews while maintaining an
inconspicuous pedestrian focus.
PUD (RMC 4-9-150.B.2.a).
4-4-080.F.10.e Required Parking Ratios -
Commercial within vertical mixed-
use developments
A minimum of 2.5 per 1,000 square feet of net floor area and a maximum of 5.0 per
1,000 square feet of net floor area.
Proposed reduced minimum of 2 spaces per 1,000 NSF floor area. The district is well
served by the Sounder commuter rail line and the RapidRide F Line. It is also planned to
have a diverse mix of uses with dissimilar peak-hour demands, so much of the parking
will be able to serve multiple uses. Many of the visitors to commercial uses on the site
will also be new residents of the site who will visit as pedestrians.
PUD (RMC 4-9-150.B.2.a).
4-4-080.F.10.e Required Parking Ratios - Assisted
Living
A minimum and maximum of 1.0 space per residential unit of assisted living, plus
dedicated parking spaces for facility fleet vehicles.
Proposed reduced minimum of 0.5 spaces per residential unit of assisted living. The
district is well served by the Sounder commuter rail line and the RapidRide F Line. It is
also planned to have a diverse mix of uses with dissimilar peak-hour demands, so much
of the parking will be able to serve multiple uses.
PUD (RMC 4-9-150.B.2.a).
4-4-080.F.10.e Required Parking Ratios - Attached
dwellings within all other zones
1.0 per dwelling unit is required. A maximum of 1.75 per dwelling unit is allowed Proposed reduced minimum of 0.9 spaces per dwelling unit (DU). The district is well
served by the Sounder commuter rail line and the RapidRide F Line. It is also planned to
have a diverse mix of uses with dissimilar peak-hour demands, so much of the parking
will be able to serve multiple uses.
PUD (RMC 4-9-150.B.2.a).
4-4-080.F.10.e Required Parking Ratios - Hotels and
Motels
A minimum and maximum of 1.0 per guest room plus 1.0 for every 3 employees.Proposed reduced minimum of 0.75 spaces per guest room. The district is well served by
the Sounder commuter rail line and the RapidRide F Line. It is also planned to have a
diverse mix of uses with dissimilar peak-hour demands, so much of the parking will be
able to serve multiple uses.
PUD (RMC 4-9-150.B.2.a).
4-4-080.F.10.e Required Parking Ratios - Offices,
Medical and Dental
A minimum and maximum of 5.0 per 1,000 square feet of net floor area.Proposed reduced minimum of 4 spaces per 1,000 NSF floor area. The district is well
served by the Sounder commuter rail line and the RapidRide F Line. It is also planned to
have a diverse mix of uses with dissimilar peak-hour demands, so much of the parking
will be able to serve multiple uses. Many of the visitors to commercial uses on the site
will also be new residents of the site who will visit as pedestrians.
PUD (RMC 4-9-150.B.2.a).
4-4-080.F.10.e Required Parking Ratios - Offices,
General
A minimum of 2.0 per 1,000 square feet of net floor area and a maximum of 4.5 parking
spaces per 1,000 square feet of net floor area.
Proposed reduced minimum of 1.5 spaces per 1,000 NSF floor area. The district is well
served by the Sounder commuter rail line and the RapidRide F Line. It is also planned to
have a diverse mix of uses with dissimilar peak-hour demands, so much of the parking
will be able to serve multiple uses. Many of the visitors to commercial uses on the site
will also be new residents of the site who will visit as pedestrians.
PUD (RMC 4-9-150.B.2.a).
4-4-080.F.10.e Required Parking Ratios - Eating and
drinking establishments and taverns
A minimum and maximum of 10 per 1,000 square feet of dining area.Proposed reduced minimum of 8 spaces per 1,000 NSF floor area. The district is well
served by the Sounder commuter rail line and the RapidRide F Line. It is also planned to
have a diverse mix of uses with dissimilar peak-hour demands, so much of the parking
will be able to serve multiple uses. Many of the visitors to commercial uses on the site
will also be new residents of the site who will visit as pedestrians.
PUD (RMC 4-9-150.B.2.a).
4-4-080.F.10.e Required Parking Ratios - Retail sales
and wholesale retail sales
A minimum and maximum of 2.5 per 1,000 square feet of net floor area, except
wholesale retail sales, which is allowed a maximum of 5.0 per 1,000 square feet of net
floor area if shared and/or structured parking is provided.
Proposed reduced minimum of 2 spaces per 1,000 NSF floor area. The district is well
served by the Sounder commuter rail line and the RapidRide F Line. It is also planned to
have a diverse mix of uses with dissimilar peak-hour demands, so much of the parking
will be able to serve multiple uses. Many of the visitors to commercial uses on the site
will also be new residents of the site who will visit as pedestrians.
PUD (RMC 4-9-150.B.2.a).
4-4-080.F.10.e Required Parking Ratios - Services,
on-site
A minimum and maximum of 3.0 per 1,000 square feet of net floor area.Proposed reduced minimum of 2 spaces per 1,000 NSF floor area. The district is well
served by the Sounder commuter rail line and the RapidRide F Line. It is also planned to
have a diverse mix of uses with dissimilar peak-hour demands, so much of the parking
will be able to serve multiple uses. Many of the visitors to commercial uses on the site
will also be new residents of the site who will visit as pedestrians.
PUD (RMC 4-9-150.B.2.a).
4-4-080.F.10.e Required Parking Ratios - Outdoor
and indoor sports arenas,
auditoriums, stadiums, movie
theaters, and entertainment clubs
A minimum and maximum of 1.0 for every 4 fixed seats or 10 per 1,000 square feet of
floor area of main auditorium or of principal place of assembly not containing fixed
seats, whichever is greater.
Proposed reduced minimum of 1.0 spaces for every 5 fixed seats or 8 spaces per 1,000
SF of floor area of the main auditorium, whichever is greater. The district is well served
by the Sounder commuter rail line and the RapidRide F Line. It is also planned to have a
diverse mix of uses with dissimilar peak-hour demands, so much of the parking will be
able to serve multiple uses. Many of the visitors to commercial uses on the site will also
be new residents of the site who will visit as pedestrians.
PUD (RMC 4-9-150.B.2.a).
4-4-080.F.10.e Required Parking Ratios -
Manufacturing and fabrication,
laboratories, and assembly and/or
packaging operations
A minimum of 1.0 per 1,000 square feet of net floor area and a maximum of 1.5 spaces
per 1,000 square feet of net floor area (including warehouse space).
Proposed reduced minimum of 0.9 spaces per 1,000 NSF floor area. The district is well
served by the Sounder commuter rail line and the RapidRide F Line. It is also planned to
have a diverse mix of uses with dissimilar peak-hour demands, so much of the parking
will be able to serve multiple uses. Many of the visitors to commercial uses on the site
will also be new residents of the site who will visit as pedestrians.
4-4-080.F.11.b Bicycle Parking Standards Each bicycle parking space shall be at least two feet (2') by six feet (6'), with no less than
an overhead clearance of seven feet (7'). A maneuvering area of five feet (5') shall
separate rows of bicycle parking spaces. Where the bicycle parking is abutting the
sidewalk, only the maneuvering area may extend into the right-of-way
Reduce spatial requirements where it can be shown that bicycles can be safely and
conveniently stored in a more efficient configuration - for example when stored vertically
in a dedicated bike storage room.
PUD (RMC 4-9-150.B.2.a).
4-4-100 Sign Regulations See chapter for details.TBD. District signage is still being evaluated. PUD (RMC 4-9-150.B.2.a).
4-4-150.C.2 Design Standards For vertically mixed-use buildings, the facade necessary for interior entrances, lobbies,
and areas/facilities developed for the exclusive use of the building’s residents, or their
guests (“lobby facade” for the purposes of this Section), is limited to thirty five percent
(35%) of the overall facade along any street frontage or the primary facade. The
Administrator may allow the lobby facade to exceed thirty five percent (35%) if the depth
of the commercial space exceeds the minimum required by RMC 4-4-150E, provided the
increased percentage of lobby facade is generally proportional to the increased depth of
commercial space.
The intent is to comply, but our understanding is that building amenities such as private
gyms or coworking spaces would not count toward this "lobby façade" length. Ground
floor residential units accessed from the ROW would also be excluded.
PUD (RMC 4-9-150.B.2.a).
4-4-150.E.1 Commercial Area Requirement Any development wherein dwelling units are proposed shall provide an amount of gross
commercial floor area equivalent to 40% of the building footprint(s) of all buildings on
site containing residential dwelling units
Prior conversation with the City included a reduction of total ground floor commercial
area to 25% of total building footprints, measured across the district rather than parcel
by parcel. This meets the intent of the code without requiring an overproduction of
ground floor-retail throughout the district. Retail spaces will be more successful when
concentrated at key intersections, rather than spread out as a small amount within each
building.
PUD (RMC 4-9-150.B.2.a).
4-4-150.E.2 Ground Floor Commercial Space
Standards
At a minimum, the development shall include ground floor commercial space along any
street frontage or, in the absence of street frontage, along the primary facade of the
building in conformance with the following standards:
Propose to waive the requirement that ground floor commercial space be required along
the entire length of each street frontage or primary façade. The intent is to provide as
much retail in the district as can be supported, and to avoid an overproduction of ground-
floor retail that will sit vacant for years. Consistent with our proposed modification to
RMC 4-4-150.E.1, retail space will be more successful when concentrated at key
intersections, rather than spread out as a small amount within each building.
PUD (RMC 4-9-150.B.2.a).
4-4-150.E.2.b Ground Floor Commercial Space
Standards
A minimum floor-to-ceiling height of eighteen feet (18'), and a minimum clear height of
fifteen feet (15') unless a lesser clear height is approved by the Administrator.
Propose to modify this to a 14' floor-to-ceiling minimum height. 18' floor-to-ceiling
implies a floor-to-floor height of 20'+, which is infeasible for the kind of 5/2 mixed-use
residential buildings envisioned for the site.
PUD (RMC 4-9-150.B.2.a).
4-4-030.D.2 Design Standards All sidewalks shall be constructed to the City standards and conform to standard
specifications for municipal public works constructions, commonly known as APWA
Standards.
See proposed street sections.PUD (RMC 4-9-150.B.2.a).
4-6-060 Street Standards See chapter for details.See proposed street sections.PUD (RMC 4-9-150.B.2.a).