HomeMy WebLinkAboutS-391901NOTE:
d�
TT
V J
COY)
O
1
0
W
CONTRACTOR TO RESTORE DISTURBED
I-
n
z
O
z
w
rr
Q0
T
W
W
U)
PLAT OF AMBERWOOD II SEWER
AS -BUILT SHEET S-328405
REMOVE EXISTING
SEWER CLEANO
EASEMENT AREA TO PRE -CONSTRUCTION \
CONDITIONS AFTER SEWER CONNECTION x Cn 41
s o co
° s HOUSE s°s
g u 6
006 —I1GQ ERY� x 507.9 S� 9
STA. 0+00
INTX' WITH BOUNDARY
i
t• ,, :•.t• t
It• ItW It• it• It• It• it•i:.
4•
t•
t•
it•
�� 7i�'ri�'ri�'ri�
r ri
4••t••t••t�•t�
ri
7i�'ri� 7i� r •
ri ri riri
!Orl
�r.r.r...
• :
;t�;t•;t•
;t•;.
0
to 1;t•;t
•;t•;t•
� Iti�
;t•;t•;t•
o
I�i�
1� •
;t•;t•;t•
;t•;t•;t�
�;t•;t•,
�si:�it•it�
;t•;t•;t�
�
�7
II D
00
o±
CP �
A PORTION OF THE NE 1/4, NW 1/4, SECTION 14, TOWNSHIP 23 N., RANGE 5 EAST, W.M., CITY OF RENTON, WASHINGTON
15 SEWER EASEMENT AS RECORED
ON THE PLAT OF AMBERWOOD II
SSMH 1, 48" J °'
SEE SHEET 17 m
m A
z
is
/
/
/
\ 15' SEWER EASEMENT
— — — — — — — — — — --T+77
III ,
tK
Cn
0
90
(A
CD
1
D
0
CA
J
�<1D
EX. SSMH
RIM=517.29
IE=507.42,
8" E)-IN
NOTE: IE=507.32,
8' W)-OUT
110,
rcn 7
9
z Ln
CONTRACTOR TO EXPOSE AND AS -BUILT
6
EXISTING SEWER OUTLET FROM HOUSE
; <
00
PRIOR TO INSTALLATION OF SANITRAY SEWER
�
I�
"1'6
rI
SYSTEM SHOWN ON PLANS. CONTACT ENGINEER
z �
�
OF LOCATION, INVERT ELEVATION, AND SIZE
m 2 P
"I', I',
vwi�
PRIOR TO CONSTRUCTION OF SEWER
�'9
cnx
s
Iv UU 29'09" t 616.JT -
/ 72 s7) s7� sj
7 J
r � 7
C7 x
x
o
x S x
s, s�
AO
I S x S
7s° SAS �s
x/co
/o. x
x S,
ss
Co
1
I Q
0
L
I
x
�
'sLQ
I I
fZ
--------�
I
ram—
can
I
0-
I
I
I
0
I
I
� I
I
00
I
N
s LL_
® ,1 I o
Z/7
SSMH 5, 48"0
0
m D
RIM=519.00
0
IE=511.05, 6" E
-IN
—
N +
IE=510.95, 8"�S�-OUT
®I I SHA A NUE NE ® ng
3+00
- 262LF. 8 PVC SS @0_=1.4%— -
I
�
I
SSMH 3 48"
Am8"
SSMH 4, 4
RIM=513.23
IE=506.26, 8
N)-IN
2- I
RIM=514.12
IE=507.14, 8" N,-IN
)OUT
_ N
�' D
_
m
IE=506.16, 8"�
W)-OUT
C
IE=507.04, 8"IS)
cn '
II D
UT
I
�+
N+
0 47LF.
8'' PVC
ml
C
cc) �
I SS @S=1.66%
I
1
�� i
Z
Z
I�
®
p
°°
Cb
�
Ln
SEE SHEET 17
0000 O
j I
INSTALL 6'' SIDE SEWER
PER STD. PLAN #406.1
(TYPICAL)
4+00 40)
—1
A.
\O
07
/ SEWER CLEANOUTS BEHIND
SIDEWALK SHALL BE LOCATED IN
EX. SSM 2'X2' CONCRETE PAD ADJACENT
RIM-51 .36 TO THE BACK OF WALK.
IE=5 6, " W (TYPICAL)
=507a51 8"�E)
�O
� O
x
x s�o
x S, Q
9°
9
S �
l
STA. 0+39
IE=513.48
0/
I PO I
Q
I
--- I w
w
m
�tK
STA. 1 + 14 0 \10 N
IE=513.51
5 5'
TRACT C
SSMH#7, 48" 0
RIM=519.93
IE=512.58, 6"P-OUT
-IN
IE=512.48, 8"
I� I z
I
I s��
I 9
j 4 SSMH 6 48"
' I RIM=519.38
IE=512.13, 8" E)-IN
RIM=523.0 IE=512.03, 8" W)-OUT
E I=518.0, 6
I "
-- �
---
EXISTING UTILITY LOCATIONS SHOWN HEREON ARE
APPROXIMATE ONLY. IT SHALL BE THE CONTRACTOR'S
RESPONSIBILITY TO DETERMINE THE EXACT VERTICAL AND
HORIZONTAL LOCATION OF ALL EXISTING UNDERGROUND
UTILIITES PRIOR TO COMMENCING CONSTRUCTION. NO
REPRESENTATION IS MADE THAT ALL EXISTING UTILITIES
ARE SHOWN HEREON. THE ENGINEER ASSUMES NO
RESPONSIBILITY FOR UTILITIES NOT SHOWN OR UTILITIES
NOT SHOWN IN THEIR PROPER LOCATION.
CALL BEFORE YOU DIG: 811
SHALLOW SANITARY SEWER
0o I MANHOLES PER STANDARD
PLAN #400.2
0
07
I
O� I
I
I I
I
I
1
ALL
SANITARY SIDE
SEWER
STUBS SHALL BE PVC PLACED
AT
MINIMUM SLOPE=2.00%,
TYPICAL.
_o
GRAPHIC SCALE
+ z 0 15 30 60
A
1�
Ilk
O
C0
O
O
1
Q
J
01 0
520 I FINISHED PROFILE AT al m 520
..............:...... CENTER:LINE OF ROAD . ........... ............... ............... ............... ............... ............... ..................... ............ ............. ............. .erg...... ............... :............. .
12" STORM 1 inch = 30 feet
Q O
I I 07 AS -BUILT 12-12-2018
o ............... ............... ............... ...... ...... ............... ............. .. ............. ............. ............. .............
0
II
ml 12" STORM 12" STORM I II 0 CONSTRUCTION RECORD DRAWING
II THIS CONSTRUCTION RECORD DRAWING IS A COPY OF A CAD FILE PREPARED
12" STORM 7 A, 130LF, 8" PV I I BY OFFE ENGINEERS, PLLC AND HAS BEEN EDITED TO REFLECT FIELD VERIFIED
510 / ,� C SS@S=1.45% Z D C SS@S, 07 I I 510 INVERT AND RIM ELEVATIONS OF THE STORM, SANITARY AND WATER SYSTEM. FIELD
......................................................... .............. 0................. ............... ............ f .. 8 .. PV.. ..... .. ............... ............... .............. :.............................. .0.......:.... .....� ..:.............. ... .... 3..55. ......:.........I. I ....................:...............
262L ' z o I I VERIFIED INVERT AND RIM ELEVATIONS WERE PROVIDED BY PACIFIC COAST SURVEYS, INC.,
w I I I I ON DECEMBER 10, 2018. THE ON -SITE PRIVATE STORM DRAINAGE AND PUBLIC/PRIVATE
�g" PVC SSMH 5 48" "" o w EX. 8_' SEW
WATER AND SEWER SYSTEMS WERE INSTALLED IN ACCORDANCE WITH THE APPROVED
47:LF O 0 > _ : _— — _ _ER . PLANS AND THE DOCUMENTED FIELD REVISIONS AND FUNCTION AS INTENDED.
RIM=519.00 00 r7 0-
SS @ S=1.66% IE=51 1.05, 6" E -IN °' 00 00 00 �5:-32840 ��
............... :............... :............... :............... :............... :............... :............... :............... :............... :............... :............... :............... :........... I.E= .10..95,.. 8. S .-O.UT .......:.............. �. �.N.� ...
07 SSMH 3 48"LO
�L. �.0..��.�0................. -
RIM=51,3.23 J II =
� EX. SSMH RECORD DRAWINGS S 391901
°� SSMH 4 48" ���`'�`' �� �LII LII RIM=517.29
IE=506.26, 8 N)-IN Z N m w w IE-507.42, 8" E)-IN IN COMPLIANCE WITH CITY OF RENTON STANDARDS
IE=506.:16, 8 jW)-OUT RIM=514.12 A IE=507.32, 8"jW)-OUT
500 IE=507.14, 8 N,E)-IN SHADOW AVENUE NE —
.......................................................................................................................................................................................................... ...............;...07 ... ... ............. ............. ............. ............. ............. .............
IE=507:g4; .8„ S}-OUT..........
NE 3rd COURT 500
HORIZONTAL SCALE: 1 "=30'
3+00 4+00 VERTICAL SCALE. 1 "=5' Q
0+00 1 +00 2+00 J
7.............. ............... AS -BUILT............................. DLO ..12./2018........................;............... ;...............;...............;.............. ............. ............. .............
pay, 6 REVISED ROCKERY TO SAVE TREE DLO 9/2018 5+00 6+00
OFFS ENGINEERS ��oF�WASy,N�To 5 REVISED VAULT PER CITY COMMENTS DLO 6/2018 sT RANE SURVEYING SCALE. HORIZONTAL: AVD 198,ss, DATE. T
�� y. 4 REVISED PER CITY COMMENTS DLO 2/2018 CITY OF RENTON 14 PLAT 12/12/2018
13932 SOUTHEAST 159TH PLACE Ao _ >� DESICND.L. ONE, P.E.
FlELDBOOK:
3 REVISED PER CITY COMMENTS DLO 1/2018 RENTON KENDALL HOMES, INC. PAGE:
RENTON, WASHINGTON 98058 2 REVISED PER CITY COMMENTS DLO 9 2017 DRAWN:
D.L. OFFE, P.E. DRAWING N0:
PHONE: 425-260-3412 27460 ONE INCH WASTEWATER PLAN &PROFILE
��`��c/STE���`�0 1 REVISED PER CITY COMMENTS DLO 2/2017 CHECKED: AT FULL SCALE DATUM Planning/Building/Public Works Dept. z
CONTACT: DARRELL OFFE, P.E. FSS�ONAL�APPROVED: SCALE ACCORDINGLY 6201 NE 4th STREET SHEET: OF: w
12/12/2018 N0. REVISION BY DATE APPR 16 28 Ir