Loading...
HomeMy WebLinkAboutR-391907J In Z 0 Z W Lv Q Z L, INFLOW RISER PIPE (PRINCIPAL SPILLWAY) OPEN AT TOP WITH TRASHRACK \ DEWATERING DEVICE (SEE RISER DETAIL) FLOW STABILIZED ER TLET OR CRESTOF 6• MIN. WIDTH EMERGENCY SPILLWAY 1' MIN. EMEIANKMENi COMPACTED 95%. PERVIOUS MATERIALS SUCH AS } GRAVEL OR CLEAN SAND SHALL NOT BE USED. ------------- WIRE-BACKED SILT FENCE, / DEWAORIFICE TERING ' 1111 -I III- Ill Il- I STAKED HAYBALES WRAPPED �1 I =11 1 11-11 1-111- WITH FILTER FABRIC, OR DISCHARGE TO STABILIZED EQUIVALENT DIVIDER CONCRETEBASE CONVEYANCE, OUTLET OR LEVEL SPREADER NOTES 1. CONDITION OF USE 1.1 A SEDIMENT POND SHALL BE USED WHERE THE CONTRIBUTING DRAINAGE AREA IS 3 ACRES OR MORE. 2. DESIGN AND INSTALLATION SPECIFICATIONS 2.1. THE POND SHALL BE DIVIDED INTO TWO ROUGHLY EQUAL VOLUME CELLS BY A PERMEABLE DIVIDERTHAT WILL REDUCE TURBULENCE WHILE ALLOWING MOVEMENT OF WATER BETWEEN CELLS. THE DIVIDER SHALL BE AT LEAST ONE HALF OF THE HEIGHT OF THE RISER. WIRE - BACKE , 2-TO 3 FOOT HIGH, EXTRA STRENGTH FILTER FABRIC SUPPORTED BY TREATED 4"X4"s MAY BE USED AS A DIVIDER. ALTERNATIVELY, STAKED STRAW BALES WRAPPED WITH FILTER FABRIC MAYBE USED. 2.2. IF THE POND IS MORE THAN 6 FEET DEEP, A DIFFERENT MECHANISM MUST BE PROPOSED. 2.3. TO AID IN DETERMINING SEDIMENT DEPTH, ONE -FOOT INTERVALS SHALL BE PROMINENTLY MARKED ON THE RISER. 3. MAINTENANCE STANDARDS 3.1. SEDIMENT SHALL BE REMOVED FROM THE POND WHEN IT REACHES 1 FOOT IN DEPTH. 3.2. ANY DAMAGES TO THE POND EMBANKMENTS OR SLOPES SHALL BE REPLACED. PUBLIC WORKS SEDIMENT POND PLAN VIEW STD. PLAN - 218.00 DEPARTMENT AND CROSS SECTIONS gN,,f MARCH 2O08 5' MAX. DRAINAGE GRATE TRIM rc GRATE FRAME 3 SEDIMENT AND DEBRIS a OVERFLOW BYPASS •° C BELOW INLET GRATE DEVICE ° FILTERED WATER SECTION VIEW DRAINAGE GRATE -RECTANGULAR GRATE SHOWN RETRIEVAL SYSTEM (TVP.) BELOW INLET GRATE DEVICE OVERFLOW BYPASS(TYP.) ISOMETRIC VIEW NOTCS 1. Size the Below Inlet Grate Device (BIGD) for the storm water structure It will service. 2. The BIGD shall have a bulk -In high -flow relief system (oveAlow bypass). 3. The retrieval system must allow removal of the BIGD without spilling the collected material. 4. Perform maintenance In accordance with Standard Specification M1.3(15). Y STD. PLAN - 218.30 * PUBLIC WORKS CATCH BASIN FILTER DEPARTMENT FNTp MARCH 2O08 EROSION CONTROL WET SEASON REQUI REM ENTS Sites with exposed soils during the WET SEASON (October 1 to April 30) shall be subject to special erosion control provisions. These special provisions are required in addition to the standard TESC cover measures. Please notify contractor of these requirements. All projects that clear, grade or otherwise disturb the site, must provide erosion and sediment controls to the maximum extent possible, to prevent the transport of sediment from the project site to downstream drainage facilities, water resources, and adjacent properties. The following provisions for wet season construction are detailed in Appendix D of the 2009 King Count Surface Water Manual. Please ensure your site is protected and complies with the special provisions outlined below The basic requirements are: 1. The allowed time that a disturbed area can remain unworked without cover measures is reduced to two (2) days, rather than seven (7) days. 2. Stockpiles, steep cut, and fill slopes areto be covered or protected with mulch, sod, plastic covering, jute mat etc. if left unworked for more than 12 hours. 3. Cover materials (plastic, matting, etc) sufficient to cover all disturbed areas, shall be stockpiled and available on site. 4. All areas that are to be unworked during the wet season shall be seeded within one week of the beginning of the wet season. Seeded should be completed by September 23. 5. Mulch is required to protect all seeded areas. S. Fifty linear feet of silt fence (and the necessary stakes) per disturbed acre must be stockpiled on site. 7. Property installed silt fencing is mandatory along the downslope of all disturbed areas of the site. Perimeter protection filters runoff and reduces the amount of sediment that may leave the site. B. Sediment retention is required unless no offsite discharge is anticipated for the specified design flow. 9. Construction road and parking lot stabilization are required for all sites unless the site is underlain by course -grained soil. 10. Surface water controls are required unless no offsite discharge is anticipated for the specified design flow. 11. Phasing and more conservative BMPS must be evaluated for construction activity near surface waters. 12. Any runoff generated by dewatering shall be treated through construction of a sediment trap when there is sufficient space or by releasing the water to a well vegetated, gently sloping area. Since pumps are used for dewatering, it may be possible to pump the sediment -laden water well away from the surface water so that vegetation can be more effectively utilized for treatment. A straw bale filter shall be placed around the discharge from the dewatering pump. If there is not space for a sediment trap or 25 feet of suitable vegetation, other filtration methods shall be required. 13. The frequency of maintenance review should be increased from weekly to daily where warranted. E%L�SSVA �OPQ / INSTALL DRIVEWAY CULVERT IF THERE IS A ROADSIDE DITCH PRESENT, AS PER CITY ROAD STANDARDS 4"-8" QUARRY SPALLS GEOTEXTILE DRIVEWAYS SHALL BE PAVED TO THE EDGE OF RAW PRIOR TO INSTALLATION OF THE CONSTRUCTION ENTRANCE TO AVOID DAMAGING OF THE ROADWAY IT IS RECOMMENDED THAT THE ENTRANCE BE CROWNED SO THAT RUNOFF DRAINS OFF THE PAD ,y 12" MIN. THICKNESS PROVIDE FULL WIDTH OF NOTES MIGRESWEGRESS AREA 1. CONDITION OF USE 1.1. CONSTRUCTION ENTRANCE SHALL BE STABILIZED WHEREVER TRAFFIC WILL BE LEAVING A CONSTRUCTION SITE AND TRAVELING ON PAVED ROADS OR OTHER PAVED AREAS WITHIN 1,000 FEET OF THE SITE. GRAB TENSI LE STREBNGTH(ASTM D4751) 200 PSI MIN. GRAB TENSI LE ELONGATION (ASTM D4632) 30-A MAX. MULLEN BURST STRENGTH (ASTM D3786-80A) 400 PSI MIN. AOS (ASTM D4751) 20-45 (U.S. STAN DARDSIEVE SIZE) 2. DESIGN AND INSTALLATION SPECIFICATIONS 2.1. HOG FUEL (WOOD BASED MULCH) MAY BE SUBSTITUTED FOR OR COMBINED WITH QUARRY SPALLS IN ARES THAT WILL BOT BE USED FOR PERMANENT ROADS. HOG FUEL IS NOT RECOMMENDED FOR ENTRANCE STABILIZATION IN URBAN AREAS. THE INSPECTOR MAY AT ANYTIME REQUIRE THE USE OF QUARRY SPALLS IF THE HOG FUEL IS NOT PREVENTING SEDIMENT FROM BEING TRACKED ONTO PAVEMENT OR IF THE HOG FUEL IS BEING CARRIED ONTO PAVEMENT. 2.2. FENCING SHALL BE INSTALLED AS NECESSARY TC RESTRICT TRAFFIC TO THE CONSTRUCTION ENTRANCE. 2.3. WHENEVER POSSIBLE, THE ENTRANCE SHALL BE CONSTRUCTED ON A FIRM, COMPACTED SUBGRADE. THIS CAN SUBSTANTIALLY INCREASE THE EFFECTIVENESS OF THE PAD AND REDUCE THE NEED FOR MAINTENANCE. 3. MAINTENANCE STANDARDS 3.1. QUARRY SPALLS SHALL BE ADDED IF THE PAD IS NO LONGER IN ACCORDANCE WITH THE SPECIFICATIONS. 3.2. IF THE ENTRANCE IS NOT PREVENTING SEDIMENT BEING TRACKED ONTO PAVEMENT, THEN ALTERNATIVE MEASURES TO KEEP THE STREETS FREE OF SEDIMENT SHALL BE USED. THIS MAY INCLUDE STREET SWEEPING, AN INCREASE IN THE DIMENSIONS OF THE ENTRANCE, OR THE INSTALLATION OF THE WHEEL WASH. IF WASHING IS USED, IT SHALL BE DONE ON AN AREA COVERED WITH CRUSHED ROCK, AND WASHED WATER SHALL DRAIN TO A SEDIMENT TRAP OR POND. 3.3. ANY SEDIMENT THAT IS TRACKED ONTO PAVEMENT SHALL BE REMOVED IMMEDIATELY BY SWEEPING. THE SEDIMENT COLLECTED BY SWEEPING SHALL BE REMOVED OR STABILIZED ON SITE. THE PAVEMENT SHALL NOT BE CLEANED BY WASHING DOWN THE STREET, EXCEPT WHEN SWEEPING IS INEFFECTIVE AND THERE IS A THREAT TO PUBLIC SAFETY. IF IT NECESSARY TO WASH THE STREETS, A SMALL SUMP MUST BE CONDUCTED. THE SEDIMENT WOULD THEN BE WASHED INTO THE SUMP WHERE IT CAN BE CONTROLLED AND DISCHARGED APPROPRIATELY. 3.4. ANY QUARRY SPALLS THAT ARE LOOSENED FROM THE PAD AND END UP ON THE ROADWAY SHALL BE REMOVED IMMEDIATELY. 3.5. IF VEHICLES ARE ENTERING OR EXITING THE SITES AT POINTS OTHER THAN THE CONSTRUCTION ENTRANCE(S), FENCING SHALL BE INSTALLED TO CONTROL TRAFFIC. ti�Y o �(� `♦ PUBLIC WORKS STABILIZED STD. PLAN - 215.10 DEPARTMENT CONSTRUCTION ENTRANCE '�'�•N,tO MARCH 2O08 OFJP E 1JE� ° °P`c� OF WASy�NcT,°°e. 13932 SOUTHEAST 159TH PLACE °� 3 REVISED PER CITY COMMENTS RENTON, WASHINGTON 98058 ° 2 REVISED PER CITY COMMENTS PHONE: 425-260-3412°`�c�STER��°�° 1 REVISED PER CITY COMMENTS CONTACT: DARRELL OFFE, P.E. Fss/ONAL° N0. REVISION 01/15/2018 POLYETHYLENE CAP PERFORATED POLYETHYLENE DRAINAGE TUBING, DIAMETER MIN. 2" LARGER THAN DEWATERING ORIFICE TUBING SHALL COMPLY WITH ASTM F667 AND AASHTO M294, PROVIDE ADEQUATE STRAPPING CORRUGATE METAL RISER 3.5' MIN. WATERTIGHT DEWATERING ORIFICE, SCHEDULE COUPLING TACK WELD 40 STEEL STUB MIN. / DIAMETER AS PER CALCULATIONS 6' MIN. 18' MIN. ALTERNATIVELY, METAL STAKES AND WIRE MAYBE USED TO CONCRETE BASE PREVENT FLOTATION 2% RISER DIA. MIN, tir ° STD. PLAN - 216.10 Gn PUBLIC WORKS SEDIMENT POND �P��� DEPARTMENT RISER DETAIL �:N,tp MARCH 2O08 JOINTS IN FILTER FABRIC SHALL BE SPLICED AT POSTS. USE STAPLES, WIRE RINGS, OR El1I 1IVAI PNT Tn ATTArH EARR1r TA Pr.CTC 6' MAX. u � POST SPACING MAY BE INCREASED TO 8' IF WIRE BACKING IS USED 2"X2' BY 14 Ga. WIRE OR EQUIVALENT, IF STANDARD STRENGTH FABRIC USED FILTER FA MINIMUM 4'k4"TRENCH BACKFILL TRENCH WITH NATIVE SOIL 2-X4" WOOD POSTS, STEEL FENCE / POSTS, REBAR, OR EQUIVALENT NOTES 1. CONDITION OF USE 1,1. SILT FENCE MAY BE USED DOWNSLOPE OF ALL DISTURBED AREAS. 1,2. SILT FENCE IS NOT INTENDED TO TREAT CONCENTRATED FLOWS, NOR IS INTENDED TO TREAT SUBSTANTIAL AMOUNTS OF OVERLAND FLOW. ANY CONCENTRATED FLOW MOST BE CONVEYED THROUGH THE DRAINAGE SYSTEM TO A SEDIMENT TRAP OR POND. 2. DESIGN AND INSTALLATION SPECIFICATIONS 2,1. THE GEOTEXTILE USED MOST MET THE STANDARD LISTED BELLOW. A COPY OF THE MANUFACTURER'S FABRIC SPECIFICATIONS MOST BE AVAILABLE ON SITE. I1 1:S1IE SIZE(0.60-D15MM) FOR SILT FILM A05 (ASTM D4751) SO10051EVESIZE 0.30-0. 15MM) FOR OTHER FABRICS WATER PERMFTTIVITV ASTM D491 0.Q SEC"-1 MINIMUM GRABTENSILESTP.ENCHT(ASTMD4632) 180LBS. MIN. FOREXTRASTRENGH FABRIC 300 LBS. MIN. FOR STANDARD STRENGHT FABRIC GRAB TENSILE ELONGATION (ASTM D4632) 30Y MAX. ULTRAVIOLATE RESISTANCE (ASTM D43551 70% MIN. 2.2. STANDARD STRENGTH FABRIC REQUIRES WIRE BACKING TO INCREASE THE STRENGTH OF THE FENCE. WIRE BACKING OR CLOSER POST SPACING MAY BE REQUIRED FOR EXTRA STRENGTH FABRIC IF FIELD PERFORMANCE WARRANTS A STRONGER FENCE. 2.3. WHERE THE FENCE IS INSTALLED, THE SLOPE SHALL NOT BE STEEPER THAN 2H:1V 2.4. IF ATYPICAL SILT FENCE IS USED, THE STANDARD 4X4 TRENCH MAY NOT BE REDUCED AS LONG AS THE BOTTOM 8 INCHES OF THE SILT FENCE S WELL BURIED AND SECURE IN A TRENCH THAT STABILIZES THE FENCE AND DOES NOT ALLOW WATER TO BYPASS OR UNDERMINE THE SILT FENCE. 3. MAINTENANCE STANDARDS 3.1. ANY DAMAGE SHALL BE REPAIR IMMEDIATELY. 3.2. IF CONCENTRATED FLOES ARE EVIDENT UPHILL OD THE FENCE, THEY MUST BE INTERCEPTED AND CONVEYED TO A SEDIMENT TRAP OR POND. 3.3. IT IS IMPORTANT TO CHECK THE UPHILL SIDE OF THE FENCE FOR SIGNS OF THE FENCE CLOGGING AND ACTING AS A BARRIER TO FLOW AND THEN CAUSING CHANNELIZATION OF FLOWS PARALLEL TO THE FENCE. IF THIS OCCURS, REPLACE THE FENCE OR REMOVED THE TRAP SEDIMENT. 3,4. SEDIMENT MOST BE REMOVED WHEN SEDIMENT IS 6 INCHES HIGH. 3.5. IF THE FILTER FABRIC (GEOTEXTILE) HAS DETERIORATED DUE TO ULTRAVIOLET BREAKDOWN, IT SHALL BE REPLACED. 8Y n� ; PUBLIC WORKS SILT FENCE STD. PLAN - 214.00 DEPARTMENT NT MARCH 2O08 SURVEYED: TERRANE SURVEYING DESIGNED: DLO 1 /2018 D.L. OFFE, P.E. DLO 7 9 201DRAWN: / D.L. OFFE, P.E. DLO 2/201 7 CHECKED: SCALE: ONE INCH AT FULL SCALE IF NOT ONE INCH SCALE ACCORDINGLY VERTICAL: NAVD 1988 HORIZONTAL: NAD 1983/1991 DATU M Typical V-Shaped Channel Cross -Section With Rock Center \e 6• _ 9• (150-225mm) Key in Fabric Grass -Lined _/ Filter Fabric Typical Parabolic Channel Cross -Section With Rock Center for Base Flow h • i V, 6„ - 9„ (150-225mm) Key in Fabric\/ With Channel Filter Fabric Liner Typical Trapezoidal Channel Cross -Section Design Depth IV Nim Overcut channel 2" (50mm) to allow bulking during seedbed preparation With Rock Center and growth of vegetation. Filter Fabric for Base Flow NOT TO SCALE Figure II-4.2.1 Typical Grass -Lined Channels DEPARTMENT OF Revised June2015 ECOLOGY Please see http://www.ecy.wa.gov/copyright.html for copyright notice including permissions, State of Washinqton limitation of liability, and disclaimer. C TY OF RENTON ["OR V40V _ Planning/Building/Public Works Dept. R-391907 IN COMPLIANCE WITH CITY OF RENTON STANDARDS RENTON 14 PLAT KENDALL HOMES, INC. TESCP DETAILS & NOTES 6201 NE 4th STREET ,hyrllI 'H W W 00 O C) 1 J a J n DATE: 01/15/2018 Z FIELDBOOK: Z PAGE: O DRAWING NO: Z SHEET: 7 OF:2 Q W U