COMPACTED STRUCTURAL FILL
H
n FENCE PER CIVIL PLANS
I I
I
II
II
II I
6" MIN
I
I . SREINFORCEMEN-(SEE REINFORCING
I CHEDULEAT RIGHT)
LJ 4 FILM(ACTED STRUCTURAL
EE NO E 9)
3' MIN- I . 2,
1.0'
I
-KEYWAY 1P
FIRM UNDISTURBED MIN
SOIL TO BE VERIFIED
BY GEOTECHNICAL ENGINEER
KEYWAY SHOULD BE SLOPED
DOWN TOWARDS THE FACE
BEING PROTECTED
NOT TO SCALE
CRUSHED OCKFILTER
MATERIAL, BETWEEN 2
2'
AND 4 INCH SIZE WITH
I
LESS THAN 2% FINES
j
(TYP.)
.. 0.5''
-3"MINIMUM
GRAVEL BEDDING 1.0'
4" MINIMUM DIAMETER
DRAIN PIPE SURROUNDED BY
CLEAN WASHED314" DRAIN
GRAVEL
GENERALNOTES
1. REFER TO CIVIL DRAWINGS FOR WALL ALIGNMENT AND ELEVATIONS.
2, GEOTEXTILE HEIGHT MEASURED FROM GRADE IN FRONT OF ROCKERY FACE.
3. GEOGRID/GEOTEXTILE REINFORCEMENT SHALL BE INSTALLED BEHIND WALL W17H MACHINE DIRECTION
(STRONGEST AXIS) PERPENDICULAR TO WALL.
4. GEOGRID/GEOTEXTILE SHALL BE INSTALLED ON HORIZONTAL SURFACE OF COMPACTED STRUCTURAL FILL AT
ELEVATIONS SHOWN ON SCHEDULE.
5. GEOGRID/GEOTEXTILE SHALL BE PULLED TIGHT BEHIND WALL. STAKE END OF GEOGRID/GEOTEXTILE AS
REQUIRED TO MAINTAIN TENSION BEFORE COVERING WITH STRUCTURAL FILL.
B. PROTECT GEOGRID/GEOTEXTILE FROM CONSTRUCTION DAMAGE PER MANUFACTURERS' SPECIFICATIONS.
CONSTRUCTION EQUIPMENT SHALL NOT TRAVEL DIRECTLY ON GEOGRIDIGEOTEXTILE. ANY
GEOG RID/GEOTEXTILE THAT IS DAMAGED SHALL BE REPLACED WITH NEW GEOGRID/GEOTEXTILE AT
CONTRACTORS' EXPENSE.
7. GEOGRID/GEOTEXTILE SHALL BE AS SHOWN ON SCHEDULE. ALL GEOGRID/GEO-EXTILE SHALL BE CLEARLY
IDENTIFIED AND LABELED IN THE FIELD. ANY UNMARKED ROLLS, OR PORTIONS THEREOF THAT CANNOT BE
IDENTIFIED SHALL NOT BE USED IN WALL CONSTRUCTION.
8. GEOGRID/GEOTEXTILE MUST BE CONTINUOUS ALONG THE BACK OF THE WALL, INCLUDING CURVES AND
CORNERS.
9. ALL STRUCTURAL FILL TO BE PLACED AND COMPACTED PER GECTECHNICAL REPORT PREPARED BY TERRA
ASSOCIATES, INC. PROJECT NO. T-7290, DATED SEPTEMBER 30, 2)16. STRUCTURAL FILL IN REINFORCED ZONE
SHALL BE GRANULAR MATERIAL WITH A MAXIMUM AGGREGATE SIZE OF 31NCHES AND A MAXIMUM OF 30
NOTE:
1. REFER TO LANDSCAPE DWGS FOR
SPECIFIC TREES TO BE FENCED.
�V INSTALL TREE
I
PRESERVATION
(FENCE 5' FROM
DRIP LINE
w
z
aOf
0
SIGNIFICANT
EXISTING TREE 5'_
TO TO BE SAVED
MARK TREES TO BE
SAVED WITH FLAGGING
,I TYPICAL EXISTING TREE PROTECTION
N.T.S.
1-7/8" STRUCTURAL
WEIGHT STEEL POST
SET 2' BELOW GRADE
WITH 11 GAUGE
GALVANIZED CHAINLINK
MESH. SET POSTS 10'
O,C. MAX.
6'-0" TYP.
2'-0" TYP.
TREE PROTECTION SIGNS
TO BE PLACED ON FENCE
MAXIMUM SPACING OF 50'
ON CENTER
A PORTION OF THE NE1/4 , NW1/4, SECTION 14, TOWNSHIP 23 N., RANGE 5 EAST, W.M., CITY OF RENTON, WASHINGTON
REINFORCED FILL ROCKERY REINFORCING SCHEDULE
REINFORCEMENT
HEIGHT
EXPOSED WALL
LAYER N0,
(USE MIRAFI OR
LENGTH "L" FEET
(ABOVE BASE
HEIGHT
EQUIVALENT)
ELEVATION)
<4 FEET
NO REINFORMENT REQUIRED
1
MIPAFI HP 570
6.0
0.5
4-5 FEET
2
MIRAFI HP 570
6.0
2.5
1
MIRAFI HP 570
6.5
0.5
5-7 FEET
2
MIRAFI HP 570
8.5
25
3
MIRAFI HP 570
6.5
4.5
i
MIRAFI HP 570
7.5
0.5
2
MIRAFI HP 570
7.5
2.5
5.9 FEET
3
MIRAFI HP 570
7.5
4.5
4
MIRAFI HP 570
1 7.5
6.6
ROCKERY NOTES:
1. ROCKERY CONSTRUCTION SHALL BE COMPLETED
IN ACCORDANCE WITH THE ASSOCIATION OF
ROCKERY (ARC) CONTRACTORS GUIDELINES.
2, ROCK USED MUST MEET THE REQUIREMENTS
FOR ROCK QUALITY SPECIFIED IN SECTIONS 9-13 7(1)
OF THE WSDOT STANDARDS SPECIFICATIONS (2004).
3. ALL CAP ROCKS MUST BE SECURE AND NOT ABLE
TO BE DISLODGED BY HAND.
OFFE ENGINEERS
13932 SOUTHEAST 159TH PLACE
RENTON, WASHINGTON 98058
PHONE: 425-260-3412
CONTACT: DARRELL OFFE, P.E.
SEE SHEET 9
INTX' WITH BOUNDARY
TEMP. ECOLOGY
TOP=505
DIRT=500
0 o INSTALL STORM BYP
0z .
�OUTFALL SHOWN ON
m m SHEET 21
i
0
.s
4s o ;u
NF
m
514
VAULT EXCAVATION
CONTRACTOR TO VERIFY QUANTITIES
INDEPENDENTLY; QUANTITIES SHOWN ARE
FROM EARTHWORK SERVICES MEMO DATED
NOV. 28, 2016.
7
L
of °WASy�;�''c�
6
5
4
2
°
�O°,A� 27460 O °'
�Fss
12/12/2018
1
N0.
1 1 II
I 1 j
I I 11
I 1 II
I I
I
TW=513.0 TW=513.0
Ut
SO O
s > HOUSE
O)
7RY
CONNECT TO
SEE SHEET 9
__--- --x--- x
�g' s 1 +00 Nt`
INTX' STA. 20+00.00
=STA. 1 +20.50
n
------------I
I
SHEET 21
CUT/FILL QUANTITIES:
STRIPPINGS (TOP SOIL) = 2,659 CU. YDS.
EXCAVATION (CUT) = 6,357 CU. YDS.
COMPACT FILL = 5,658 CU. YDS.
STRUCTURAL NOTES
1. THESE PLANS APPROVED FOR STANDARD ROAD AND DRAINAGE IMPROVEMENTS ONLY. PLANS
FOR STRUCTURES SUCH AS BRIDGES, VAULTS, WALLS, OR RETAINING WALLS REQUIRE A SEPERATE
REVIEW AND APPROVAL BY THE CITY OF RENTON PRIOR TO CONSTRUCTION.
2. ROCKERIES ARE CONSIDERED TO BE A MEHTOD OF BANK STABILIZATION AND EROSION CONTROL.
ROCKERIES SHALL NOT BE CONSTRUCTED TO SERVE AS RETAINING WALLS. ALL ROCKERIES IN THE CITY
ROAD RIGHT-OF-WAY SHALL BE CONSTRUCTED IN ACCORDANCE WITH CITY STANDARDS. ROCKERIES
OUTSIDE OF ROAD RIGHT-OF-WAY SHALL BE CONSTRUCTED IN ACCORDANCE WITH THE
INTERNATIONAL BUILDING CODE (IBC).
INSTALL ROCKERY UNDER
INTX' STA. 21 +95.02
BOUNDARY
"V" SWALE PROFILE
SEE SHEET 9
GRAPHIC SCALE
0 20 40 80
I inch = 40 feet
AS -BUILT DLO 12/2018
REVISED ROCKERY TO SAVE TREE DLO 9/2018
REVISED VAULT PER CITY COMMENTS
DLO
6/2018
SURVEYED:
TERRANE SURVEYING
SCALE:
VERTICAL: NAVD 1958
HORIZONTAL: NAD 1983/1991
DATUM
CITY OF
RENTON E N TO N
.
Planning/Building/Public Works Dept.
REVISED PER CITY COMMENTS
DLO
2/2018
DESIGNED:
D.L. OFFE, P.E.
REVISED PER CITY COMMENTS
DLO
1/2018
REVISED PER CITY COMMENTS
DLO
9/2017
DRAWN:
D.L. OFFE, P.E.[;%Rl
ONE INCH
REVISED PER CITY COMMENTS
DLO
2/2017
CHECKED:
AT FULL SCALE
IF NOT ONE INCH
SCALE ACCORDINGLY
REVISION
BY
DATE
AP P R
APPROVED:
EXISTING UTILITY LOCATIONS SHOWN HEREON ARE
APPROXIMATE ONLY. IT SHALL BE THE CONTRACTOR'S
RESPONSIBILITY TO DETERMINE THE EXACT VERTICAL AND
HORIZONTAL LOCATION OF ALL EXISTING UNDERGROUND
UTILIITES PRIOR TO COMMENCING CONSTRUCTION. NO
REPRESENTATION IS MADE THAT ALL EXISTING UTILITIES
ARE SHOWN HEREON. THE ENGINEER ASSUMES NO
RESPONSIBILITY FOR UTILITIES NOT SHOWN OR UTILITIES
NOT SHOWN IN THEIR PROPER LOCATION.
CALL BEFORE YOU DIG: 811
CONSTRUCTION RECORD DRAWING c
THIS CONSTRUCTION RECORD DRAWING IS A COPY OF A CAD FILE PREPARED
BY OFFE ENGINEERS, PLLC AND HAS BEEN EDITED TO REFLECT FIELD VERIFIED
INVERT AND RIM ELEVATIONS OF THE STORM, SANITARY AND WATER SYSTEM. FIELD
VERIFIED INVERT AND RIM ELEVATIONS WERE PROVIDED BY PACIFIC COAST SURVEYS, INC.,
ON DECEMBER 10, 2018. THE ON -SITE PRIVATE STORM DRAINAGE AND PUBLIC/PRIVATE
WATER AND SEWER SYSTEMS WERE INSTALLED IN ACCORDANCE WITH THE APPROVED
PLANS AND THE DOCUMENTED FIELD REVISIONS AND FUNCTION AS INTENDED.
RECORD DRAWINGS R-391908
IN COMPLIANCE WITH CITY OF RENTON STANDARDS
RENTON 14 PLAT
KENDALL HOMES, INC.
GRADING PLAN
6201 NE 4th STREET
W
O
O
O
O
1
`1J
T
J
a
J
DATE: T
1=1 2/ K2/2018 z
PAGE: O
DRAWING NO:
W
SHEET: 8 OF:2 Q
CJ