1. Not used.
2. All ramp and lending edges shall be separately formed.
3. Utilities structures that must remain are to be made non -slip or non-skid.
4. Utilities structures such as vaults and junction boxes shall not be located in the Pedestrian Access Route (PAR) of the
Pedestrian Circulation Route.
5. Drainage appulanances, such as manholes, catch basins, etc. shall not bB located in the PAR These snould be located
in the street or the buffer strip.
6. Accessible pedestrian access shall be provided for during construction.
t�Y o STD. PLAN - 102.1
PUBLIC WORKS UTILITY PLACEMENT IN PPR 'ED:
DEPARTMENT CEMENT CONCRETE SIDEWALK 40
FN f�00049-
Gregg Zimmerman, Public Works Administrator
FRAME AND VANED GRATE
SEE NOTE 4
CLEAN SURFACE AND BOTTOM AREA.
PROVIDE UNIFORM CONTACT.
THE SURFACE AREA OF THE BASE SECTION MUST
BE GROUTED TO THE BOTTOM AREA OF ThE
ADJUSTMENT SECTION.
BASE SECTION
NOTES
1. THE COVER OR GRATING OF A CATCH BASIN SHALL NOT
BE GROUTED TO FINAL GRATE UNTIL THE FINAL
ELEVATION OF THE PAVEMENT, GUTTER, DITCH, OR
SIDEWALK IN WHICH IT IS TO BE PLACED HAS BEEN
ESTABLISHED, AND UNTIL PERMISSION THEREAFTER IS
GIVEN BY THE ENGINEER TO GROUT OR GRATING IN
PLACE IN ACCORDANCE WITH STANDARD SPECIFICATION
7-05.3.
2. SHIMS SHALL NOT BE USED TO SET FRAME TO GRADE.
THE USE OF SHIMS IS PROHIBITED.
3. MORTAR SHALL BE PLACED BETWEEN ADJUSTMENT
RINGS AND BRICKS PRIOR TO PLACEMENT,
4. THE USE OF BRICKS IS PERMITTED WHERE THE BRICKS
ARE STAGGERED TO CREATE A RUNNING BOND OR %2
BOND.
PUBLIC WORKS CATCH BASIN INSTALLATION STD. PLAN - 202.00
DEPARTMENT
FN tp MARCH 2O08
o
°a
CATCH BASIN FRAME AND VANED GRATE (DETAIL 204.00)
HANDHOLD
o
�
n
RECTANGULAR ADJUSTMENT SECTION
`v
CR CIRCULAR ADJUSTMENT SECTION
D
GROUT TYPICAL SEE NOTE 5
w
U
FLAT SLAB TOP
z
z
o
w
48', D4', a0', 72-, B4. OR ea•
.
�MORTAR(TYP.)
STEPS OR
LADDER
TE
� Z L
Z
MORTAR FILLET IN STEEL (TVP.)
12. GRAVEL BACKFILL FOR
T PPE ZONE BEDDING
SEPARATE BASE INTEGRAL BASE
CAST -IN -PLACE PRECAST WITH RISER
•o• RNG
tz•
GRAVEL BACKFILL FOR
S.� PIPE ZONE BEDDING
SEPARATE BASE
PRECAST
CATCH BASIN DIMENSIONS
MINIMUM BASE REINFORCING STEEL
CATCH WALL BASE MAXIMUM DISTANCE M2f_ IN EACH DIRECTION
DIAMETER R THICKNESS THICKNESS KN SIZE UT BETWEEN
KNOCKOUTS SEPARATE BASE INTEGRAL BASE
46" 4" 8' 36' 8" 0.23 0.15
Sq• 4.5" 8" 42' w 0.19 0.19
60• 5' 8" 48' 8• 0.25 0.25
72• 6' 8" 6V 12" 0.35 0.24
84• it 12" 72• 12• 0.39 0.29
98• 8" 12, 84• 12' 0.39 0.29
NOTES
1. No steps are required when height is 4' or less.
2. The bottom of the precast catch basin may be sloped to facilitate cleaning
3. The rectangular frame and grate must be installed with the flange down.
The frame may be cast into the adjustment section.
4. Knockouts shall have a wall thickness of 2" minimum to 2.5" maximum. Provide
a 1.5" minimum gap between the knockout wall and the outside of the pipe. After
the pipe is installed, fill the gap with joint mortar in accordance with Standard
Specification 9-04.3.
5. All grade rings, risers, and castings shall be set in mortar in accordance with
Standard Specification 9-04.3.
, Y
PIPE ALLOWANCES
NOTES
1. No steps are required when height is 4' or less.
2. The bottom of the precast catch basin may be sloped to facilitate cleaning
3. The rectangular frame and grate must be installed with the flange down.
The frame may be cast into the adjustment section.
4. Knockouts shall have a wall thickness of 2" minimum to 2.5" maximum. Provide
a 1.5" minimum gap between the knockout wall and the outside of the pipe. After
the pipe is installed, fill the gap with joint mortar in accordance with Standard
Specification 9-04.3.
5. All grade rings, risers, and castings shall be set in mortar in accordance with
Standard Specification 9-04.3.
, Y
PIPE ALLOWANCES
CATCH
PIPE MATERIAL WITH MAXIMUM INSIDE DIAMETER
BASIN
DIAMETER
CONCRETE
METAALLL
CPSSP
(1)
SOLID
WALL
PVCl�g,
PROFILE
WALL
PVCi3
48"
24"
30,
24•
27"
3o-
54"
30,
36•
30•
27'
36•
60'
39'
42'
36"
36•
42-
72'
47'
54•
42"
36'
48'
84"
54"
60•
54'
36'
48'
96"
60'
72•
60"
1 36'
1 48"
(D Corrugated Polyethylene Storm Sewer Pipe (SW. Spec. 9-05.20)
lz (Slit. Spec. 9-05.12(1 ))
(Jj (Std. Spec. 9-05.12(2))
U-1'
PUBLIC WORKS CATCHBASIN TYPE 2
DEPARTMENT
FACE OF CURB
6 117'
6 112- V
112" R. �- 1_11" R. 1:24
TOP OF
° 'ro 1rr R./'-ROADWAY
° D
D D
1
CEMENT CONCRETE
TRAFFIC CURB AND GUTTER
FACE OF ADJACENT CURB
6 1/2_" FLUSH WITH GUTTER
�- PANATSIDEWALK
RAMP ENTRANCE
1:12 1:24
TOP OF
� 12'R. ROADWAY
14
L \4
i
DEPRESSED CURB SECTION
AT SIDEWALK RAMPS
SM. PLAN - 201.00
MARCH 2O08
6' CEMENT CCNCRETE
112'R. 1-R SIDEWALKRAMIP
VARIES OR LANDING
FROM D
6"TOa
,
We"PREMOLDED
JOINT FILLER
CEMENT CONCRETE
PEDESTRIAN CURB
AT SIDEWALK RAMPS AND LANDINGS
FA-_E OF ADJACENT CURB
_s
v2••_r
SEE DEPRESSED CURB DETAIL THIS SHEET
/ 1,24
/ TOP OF
112' R. R04DWAY
!r • "D
D `DJ D
V-61
DEPRESSED CURB SECTION
AT RESIDENTIAL DRIVEWAYS ONLY,
FOR COMMERCIAL DRIVEWAYS SEE STD PLAN 1D4.2
FACE OF ADJACENT CURB
\ GUTTER SURFACE
- FACE OF CURB
a ire
i yr , ill
1l2" R. i 1"R.
I
T TOP OF
° f° ROADWAY
•D
161 D
_i
•D
' o
1" tk61/4'1"R.CEMENT CONCRETE
TRAFFIC CURB
DEPRESSED CURB DETAIL
AT RESIDENTIAL OR COMMERCIAL DRIVEWAYS, AND ALLEYS
GENERAL NOTES:
1. See standard plans 102 and 101.1 for curb expansion and contraction joint spacing.
2. Not used.
3. For Depressed Monolithic Driveway Curb 8 Gutter Section, see Standard Plan 104.2
G• PUBLIC WORKS DEPARTMENT
PL101 AN -
* DEPARTMENTCEMENT CONCRETE CURBSim
L 9 PR ED ' Z�%f�
N f 'r TrT
Gre 2immerm an. Public Works Administrate
OFFE ENGINEERS
�'y1`pF WASyo���t>
N61'.*
°DP��
y °�
13932 SOUTHEAST 159TH PLACE
°
RENTON, WASHINGTON 98058
°
PHONE: 425-260-3412
27460
CONTACT: DARRELL OFFE, P.E.
01/15/2018
3 REVISED PER CITY COMMENTS
2 REVISED PER CITY COMMENTS
1 REVISED PER CITY COMMENTS
NO. REVISION
STORM WATER STANDARD PLAN NOTES
1. THESE NOTES SHALL APPEAR ON PROJECTS FOR THE SURFACE WATER UTILITY.
2. BEFORE ANY CONSTRUCTION OR DEVELOPMENT ACTIVITY OCCURS, A PRE -CONSTRUCTION MEETING
MUST BE HELD BETWEEN THE CITY OF RENTON PLAN REVIEW SECTION AND THE APPLICANT.
3. ALL DESIGN AND CONSTRUCTION SHALL BE IN ACCORDANCE WITH THE RENTON MUNICIPAL CODE
MRMC), THE LATEST EDITION OF THE STANDARD SPECIFICATIONS FOR ROAD BRIDGE AND
UNICICPAL CONSTRUCTION PREPARED BY WSDOT AND THE AMERICAN PUBLIC WORKS
ASSOCIATION (APWA), AS AMENDED BY THE CITY OF RENTON PUBLIC WORKS DEPARTMENT.
IT SHALL BE THE SOLE RESPONSIBILITY OF THE APPLICANT AND THE PROFESSIONAL CIVIL ENGINEER
TO CORRECT ANY ERROR, OMISSION OR VARIATION FROM THE ABOVE REQUIREMENTS FOUND IN
THESE PLANS. ALL CORRECTIONS SHALL BE AT NO ADDITIONAL COST TO THE CITY.
4. APPROVAL OF THIS ROAD, GRADING, PARKING AND DRAINAGE PLAN DOES NOT CONSTITUTE AN
APPROVAL OF ANY OTHER CONSTRUCTION (e.g. DOMESTIC WATER CONVEYANCE, SEWER
CONVEYANCE, GAS, ELECTRICAL, ETC.). THE SURFACE WATER DRAINAGE SYSTEM SHALL BE
CONSTRUCTED ACCORDING TO THE APPROVAED PLANS, WHICH ARE ON FILE WITH THE CITY.
ANY DEVIATION FROM THE APPROVED PLANS WILL REQUIRE WRITTEN APPROVAL FROM THE CITY
OF RENTON PUBLIC WORKS DEPARTMENT, SURFACE WATER UTILITY SECTION.
5. A COPY OF THESE APPROVED PLANS MUST BE ON THE JOB SITE WHENEVER CONSTRUCTION
IS IN PROGRESS.
6. GRADING ACTIVITIES (SITE ALTERATION) ARE LIMITED TO THE HOUYRS OF 7 A.M. TO 7 P.M.,
MONDAY THROUGH SATURDAY AND NO WORK ON SUNDAY IS ALLOWED, UNLESS OTHERWISE
APPROVED WITH A WRITTEN DECISION BY THE CITY OF RENTON.
7. IT SHALL BE THE APPLICANT/CONTRACTOR'S RESPONSIBILITY TO OBTAIN ALL CONSTRUCTION
EASEMENTS NECESSARY BEFORE INITIATING OFF -SITE WORK. EASEMENTS REQUIRE CITY REVIEW
AND APPROVAL PRIOR TO CONSTRUCTION.
8. FRANCHISED UTILITIES OR OTHER INSTALLATIONS THAT ARE NOT SHOWN ON THESE APPROVED PLANS
SHALL NOT BE CONSTRUCTED UNLESS AN APPROVED SET OF PLANS THAT MEET ALL REQUIREMENTS
OF CHAPTER 4 OF THE SURFACE WATER DESIGN MANUAL ARE SUBMITTED TO THE CITY OF
RENTON.
9. DATUM SHALL BE NAVD 88 UNLESS OTHERWISE APPROVED BY THE CITY OF RENTON.
REFERENCE BENCHMARK AND ELEVATIONS ARE NOTES ON THE PLANS.
10. ANY DEWATERING SYSTEM NECESSARY FOR THE CONSTRUCTION OF STORMWATER FACILITIES MUST
BE SUBMITTED TO THE CITY OF RENTON FOR REVIEW AND APPROVAL.
11. ALL UTILITY TRENCHES AND ROADWAY SUBGRADE SHALL BE BACKFILLED AND COMPACTED TO
95% (PERCENT) DENSITY, STANDARD PROCTOR.
12. OPEN CUTTING OF EXISTING ROADWAYS FOR NON -FRANCHISED UTILITY OR STORM DRAINAGE WORK
IS NOT ALLOWED UNLESS SPECIFICALLY APPROVED BY THE CITY OF RENTON AND NOTED ON THESE
APPROVED PLANS. ANY OPEN CUT SHALL BE RESTORED IN ACCORDANCE WITH THE CITY OF
RENTON TRENCH RESTORATION STANDARDS.
13. ALL SEDIMENTATION/EROSION FACILITIES MUST BE IN OPERATION PRIOR TO CLEARING AND BUILDING
CONSTRUCTION, AND THEY MUST BE SATISFACTORILY MAINTANED UNTIL CONSTRUCTION IS
COMPLETED AND THE POTENTIAL FOR ON -SITE EROSION HAS PASSED.
14. ALL RETENTION/DETENTION FACILITIES MUST BE INSTALLED AND IN OPERATION PRIOR TO OR IN
CONJUNCTION WITH ALL CONSTRUCTION ACTIVITY UNLESS OTHERWISE APPROVED BY THE PUBLIC
WORKS DEPARTMENT, SURFACE WATER SECTION.
15. ALL PIPES AND APPURTENANCES SHALL BE LAID ON THE PROPERLY PREPARED FOUNDATION IN
ACCORDANCE WITH THE CURRENT STATE OF WASHINGTON STANDARD SPECIFICATION OF ROAD
AND BRIDGE CONSTRUCTION. THIS SHALL INCLUDE NECESSARY LEVELING OF THE TRENCH BOTTOM
OR THE TOP OF THE FOUNDATION MATERIAL, AS WELL AS, PLACEMENT AND COMPACTION OF
REQUIRED BEDDING MATERIAL, TO UNIFORM GRADE SO THAT THE ENTIRE LENGTH OF THE PIPE WILL
BE SUPPORTED ON A UNIFORMLY DENSE, UNYIELDING BASE. ALL PIPE BEDDING SHALL BE APWA
CLASS "C", WITH THE EXCEPTION OF PVC PIPE.
16. STEEL PIPE SHALL BE ALUMINIZED, OR GALVANIZED WITH ASPHALT TREATMENT #1 OR BETTER
INSIDE AND OUTSIDE.
17. ALL DRAINAGE STRUCTURES, SUCH AS CATCH BASINS AND MANHOLES SHALL HAVE SOLID LOCKING
LIDS, UNLESS OTHERWISE SHOWN ON THE APPROVED PLANS. ALL DRAINAGE STRUCTURES ASSOCIATED
WITH A PERMANENT RETENTION DETENTION FACILITY SHALL HAVE SOLID LOCKING LIDS.
18. BUILDING AND OTHER STRUCTURES SHALL BE PLACED IN ACCORDANCE WITH TABLE 4.1 EASEMENT
WIDTHS AND BUILDING SETBACK LINES.
19. ALL CATCH BASIN GRATES SHALL BE DEPRESSED 0.10 FEET BELOW PAVEMENT LEVEL.
20. ALL DRIVEWAY CULVERTS LOCATED WITHIN CITY OF RENTON RIGHT-OF-WAY SHALL BE OF SUFFICIENT
LENGTH TO PROVIDE A MINIMUM 3:1 SLOPE FROM THE EDGE OF THE DRIVEWAY TO THE BOTTOM
OF THE DITCH. ROCK FOR EROSION PROTECTION OF ROADWAY DITCHES, WHERE REQUIRED, SHALL BE
OF SOUND QUARRY ROCK PLACED TO A DEPTH OF ONE (1) F07 AND MUST MEET THE FOLLOWING
SPECIFICATIONS:
4 - 8 INCH ROCK / 40 - 70% PASSING;
2 - 4 INCH ROCK / 30 - 40% PASSING; AND
LESS THAN 2 INCH ROCK / 10 - 20% PASSING.
21. ALL BUILDING DOWNSPOUTS AND FOOTING DRAINS SHALL BE CONNECTED TO THE STORM DRAINAGE
SYSTEM, UNLESS APPROVED BY THE CITY PLAN REVIEWER OR SURFACE WATER UTILITY SECTION.
AN ACCURATELY DIMENSIONED, CERTIFIED AS -BUILT DRAWING OF THIS DRAINAGE SYSTEM WILL BE
SUBMITTED TO THE CITY UPON COMPLETION.
22. DRAINAGE OUTLETS (STUB -OUTS) SHALL BE PROVIDED FOR EACH INDIVIDUAL LOT, EXCEPT FOR
THOSE LOTS APPROVED FOR INFILTRATION BY THE CITY. STUB -OUTS SHALL CONFORM TO THE
FOLLOWING:
A. EACH OUTLET SHALL BE SUITABLY LOCATED AT THE LOWEST ELEVATION ON THE LOT, SO AS
TO SERVICE ALL FUTURE ROOF DOWNSPOUTS AND FOOTING DRAINS, DRIVEWAYS, YARD DRAINS,
AND ANY OTHER SURFACE OR SUBSURAFCE DRAINS NECESSARY TO RENDER THE LOTS SUITABLE
FOR THIER INTENDED USE. EACH OUTLET SHALL HAVE FREE -FLOWING, POSITIVE DRAINAGE TO
AN APPROVED STORMWATER CONVEYANCE SYSTEM OR TO AN APPROVED OUTFALL LOCATION.
B. OUTLETS ON EACH LOT SHALL BE LOCATED WITH A FIVE-FOOT HIGH, 2"x4" STAKE MARKED
"STORM" OD "DRAIN". THE STUB -OUT SHALL EXTEND ABOVE SURFACE LEVEL, BE VISIBLE, AND
BE SECURED TO THE STAKE.
C. PIPE MATERIAL SHALL CONFORM TO UNDERDRAIN SPECIFICATIONS DESCRIBED IN CHAPTER 4 OF
THE SURFACE WATER DESIGN MANUAL AND, IF NON-METALLIC, THE PIPE SHALL BE PLACED IN
A TRENCH WITH A TRACING WIRE ABOVE OR OTHER ACCEPTABLE DETECTION.
D. PRIVATE DRAINAGE EASEMENTS ARE REQUIRED FOR DRAINAGE SYSTEMS DESIGNED TO
CONVEY FLOWS THROUGH INDIVIDUAL LOTS.
E. THE APPLICANT/CONTRACTOR IS RESPONSIBLE FOR COORDINATING THE LOCATIONS OF ALL
STUB -OUT CONVEYANCE LINES WITH RESPECT TO OTHER UTLILITES (e.g. POWER, GAS,
TELEPHONE, TELEVISION).
SURVEYED:
TERRANE SURVEYING
DESIGNED:
DLO 1/2018 D.L. OFFE, P.E.
DLO9 2017 DRAWN -
/ D.L. OFFE, P.E.
DLO 2/2017 CHECKED:
SCALE:
ONE INCH
AT FULL SCALE
IF NOT ONE INCH
SCALE ACCORDINGLY
VERTICAL: NAVD 1988
HORIZONTAL: NAD 1983/1991
DATU M
22 F. ALL INDIVIDUAL STUB -OUTS SHALL BE PRIVATELY OWNED AND MAINTAINED BY THE LOT/HOME
OWNER.
G. STORM DRAINAGE PIPE SYSTEMS SHALL NOT PENETRATE BUILDING FOUNDATIONS, EXCEPT FOR
SUMP PUMP DISCHARGE LINES USED TO DRAIN CRAWL SPACES, PROVIDED THE SUMP PUMP
SYSTEM INCLUDES BACKFLOW PREVENTION OR A CHECK VALVE.
23. ALL DISTURBED AREAS (COMPACTED, GRADED, LANDSCAPED, ETC.) OF THE
DEVELOPMENT SITE MUST DEMONSTRATE ONE OF THE FOLLOWING: THE EXISTING DUFF LAYER
SHALL BE STAGED AND REDISTRIBUTED TO MAINTAIN THE MOISTURE CAPCITY OF THE SOIL, OR;
AMENDED SOIL SHALL BE ADDED TO MAINTAIN THE MOISTURE CAPACITY.
24. PROOF OF LIABILITY INSURANCE SHALL BE SUBMITTED TO THE CITY PRIOR TO CONSTRUCTION
PERMIT ISSUANCE.
25. ISSUANCE OF THE BUILDING OR CONSTRUCTION PERMITS BY THE CITY OF RENTON DOES NOT
RELIEVE THE OWNER OF THE CONTINUING LEGAL OBLIGATION AND/OR LIABLILTY CONNECTED WITH
STORM SURFACE WATER DISPOSITION. FURTHER, THE CITY OF RENTON DOES NOT ACCEPT ANY
OBLIGATION FOR THE PROPER FUNCTIONING AND MAINTENANCE OF THE SYSTEM PROVIDED DURING
CONSTRUCTION.
26. THE CONTRACTOR SHALL BE RESPONSIBLE FOR PROVIDING ADEQUATE SAFEGUARD, SAFETY
DEVICES, PROTECTIVE EQUIPMENT, FLAGGERS, AND ANY OTHER NEEDED ACTIONS TO PROTECT THE
LIFE, HEALTH, AND SAFETY OF THE PUBLIC, AND TO PROTECT PROPERTY IN CONNECTION WITH THE
PERFORMANCE OF WORK. ANY WORK WITHIN THE TRAVELED RIGHT-OF-WAY THAT MAY INTERRUPT
NORMAL TRAFFIC FLOW SHALL REQUIRE A TRAFFIC CONTROL PLAN APPROVED BY THE PUBLIC WORKS
DEPARTMENT, TRANSPORTATION SYSTEMS DIVISION. ALL SECTIONS OF THE WSDOT STANDARD
SPECIFICATIONS 1-07-23 TRAFFIC CONTROL SHALL APPLY.
27. PROJECT LOCATED WITHIN THE AQUIFER PROTECTION AREA (APA) SHALL COMPLY WITH SPECIAL
REQUIREMENT #6 OF THE SURFACE WATER DESIGN MANUAL AND AQUIFER PROTECTION
REGULATIONS (RMC 4-3-050).
CITY OF
RENTON
Planning/Building/Public Works Dept.
3p' 30•
.LA 20•
g d'.
�6' OR 12"
ONE 43 BAR HOOP FOR 6" HEIGHT
TWO #3 BAR HOOPS FOR 12' HEIGHT
RECTANGULAR ADJUSTMENT SECTION
HOOPS
REDUCING SECTION
#3 BAR
EACH CORNER
#3 BAR
EACH SIDE
PIPE ALLOWANCES
MAXIMUM
PIPE MATERIAL
INSIDE
DIAMETER
REINFORCED OR
18"
PLAIN CONCRETE
ALL METAL PIPE
21"
CPSSP*
(STD. SPEC. 9-05.20)
1B"
SOLID WALL PVC
21"
(STD. SPEC. 9-05.12(1))
PROFILE WALL PVC
21"
(STD. SPEC. 9-05.12(2))
* CORRUGATED POLYETHYLENE
STORM SEWER PIPE
NOTES
1, As acceptable alternatives to the rebar shown in the PRECAST BASE
SECTION, fibers (placed according to the Standard Specifications), or
wire mesh having a minimum area of 0.12 square inches per foot shall
be used with the minimum required rebar shown in the ALTERNATIVE
PRECAST BASE SECTION. Wire mesh shall not be placed in the
knockouts.
2. The knockout diameter shall not be greater than 26". Knockouts shall
have a wall thickness of 2" minimum to 2.5" maximum. Provide a 1.5"
minimum gap between the knockout wall and the outside of the pipe.
After the pipe is installed, fill the gap with joint mortar in accordance
with Standard Specification 9-04.3.
3. The maximum depth from the finished grade to the lowest pipe invert
shall be 5'.
4. The frame and grate must be installed with the flange down.
5. The Precast Base Section may have a rounded floor, and the walls may
be sloped at a rate of 1:24 or steeper.
6. The opening shall be measured at the top of the precast base section.
7. All pickup holes shall be grouted full after the basin has been placed.
8. All grade rings and castings shall be set in mortar In accordance with
Standard Specification 9-04.3.
#3 BAR HOOP 03 BAR EACH CORNER
EACH WAY SEE NOTE 1
PRECAST BASE SECTION ALTERNATIVE PRECAST BASE SECTION
ti � � + PUBLIC WORKS CATCH BASIN TYPE I STD. PLAN - 200.10
DEPARTMENT
�FNT MARCH 2O08
R-391917
IN COMPLIANCE WITH CITY OF RENTON STANDARDS
RENTON 14 PLAT
KENDALL HOMES, INC.
CITY STANDARD DETAILS
6201 NE 4th STREET
W
C)
O
O
C:)
1
T
Q
J
a
J
n
Nt
DATE:
01/15/2018 T
FIELDBOOK: z
PAGE: O
DRAWING NO:
z
LU
SHEET: OF:
20 28