HomeMy WebLinkAboutR-396701M 0 v D BRH ENGINEERING NOTES: 1. EXISTING UTILITIES AND UNDERGROUND STRUCTURES SHOWN ON THE PLAN ARE BASED UPON THE BEST AVAILABLE PUBLIC RECORDS AND/OR PRIVATE RECORDS AS SUPPLIED BY THE PROJECT OWNER AND/OR DATA OBTAINED VERBALLY FROM OWNERS OR OFFICIALS ASSOCIATED WITH THE PARTICULAR UTILITY. NEITHER THE OWNER NOR THE ENGINEER GUARANTEE THE ACCURACY OR COMPLETENESS OF THIS INFORMATION AND ASSUME NO RESPONSIBILITY FOR IMPROPER LOCATIONS OR FAILURE TO SHOW UTILITY LOCATIONS ON THE CONSTRUCTION PLANS. OTHER UNDERGROUND FACILITIES NOT SHOWN ON THE DRAWINGS MAY BE ENCOUNTERED DURING THE COURSE OF THE WORK. ALL INVERT ELEVATIONS SHOWN ON THE DRAWINGS SHALL BE VERIFIED BY THE CONTRACTOR PRIOR TO CONSTRUCTION. 2. IF CHANGED CONDITIONS ARE ENCOUNTERED, THE CONTRACTOR SHALL NOTIFY THE ENGINEER PROMPTLY OF (1) PREEXISTING SUBSURFACE CONDITIONS DIFFERING FROM THOSE INDICATED IN THE PLANS, OR (2) PREEXISTING UNKNOWN SUBSURFACE CONDITIONS, OF AN UNUSUAL NATURE, DIFFERING MATERIALLY FROM THOSE ORDINARILY ENCOUNTERED AND GENERALLY RECOGNIZED AS INHERENT IN WORK OF THE CHARACTER PROVIDED FOR IN THE CONTRACT. THE CONTRACTOR AND/OR THE OWNER SHALL MAKE NO CLAIMS TO THE ENGINEER FOR RECOMPENSATION FOR EXTRA WORK RESULTING FROM CHANGED CONDITIONS UNLESS THE ENGINEER HAS APPROVED THE WORK IN WRITING. (WSDOT SECTION 1-04.7). 3. THE CONTRACTOR SHALL CALL THE UTILITIES UNDERGROUND LOCATION CENTER FOR FIELD LOCATION OF ALL UTILITIES AND SHALL NOT BEGIN EXCAVATION UNTIL ALL KNOWN UNDERGROUND FACILITIES IN THE VICINITY OF THE PROPOSED WORK HAVE BEEN LOCATED AND MARKED. IF THE UTILITY IS NOT A SUBSCRIBER OF THE UNDERGROUND LOCATION CENTER THEN THE CONTRACTOR SHALL GIVE INDIVIDUAL NOTICE TO THAT UTILITY. (WSDOT SECTION 1-07.17 APWA SUPPLEMENT). 4. THE CONTRACTOR SHALL TAKE REASONABLE PRECAUTIONS AND EXERCISE SOUND ENGINEERING AND CONSTRUCTION PRACTICES IN CONDUCTING THE WORK. THE CONTRACTOR SHALL PROTECT EXISTING PUBLIC AND PRIVATE UTILITIES FROM DAMAGE DURING CONSTRUCTION. IF EXISTING UTILITIES ARE DAMAGED, THE CONTRACTOR SHALL IMMEDIATELY NOTIFY THE OWNER AND THE ENGINEER. THE CONTRACTOR SHALL RESTORE THE UTILITY TO ITS EXISTING CONDITION. (WSDOT SECTION 1-07.17 APWA SUPPLEMENT). THE CONTRACTOR IS RESPONSIBLE FOR THE MEANS AND METHODS OF CONSTRUCTION FOR DESIGNS SHOWN ON THESE PLANS. 5. WHERE THE PLANS CALL FOR UTILITIES TO BE RELOCATED BY OTHERS, THE CONTRACTOR SHALL NOTIFY THE UTILITY COMPANY AND COORDINATE HIS WORK SO AS TO AVOID CONFLICTS. 6. ALL EXCAVATION, TRENCHING, SUBGRADE PREPARATION, FILL PLACEMENT AND COMPACTION AND ALL SOIL WORK IN GENERAL SHALL BE CONDUCTED IN COMPLIANCE WITH THE RECOMMENDATIONS OF THE PROJECT SOIL ENGINEER AND THE CURRENT GEOTECHNICAL ENGINEERING REPORT. 7. ENGINEERING DESIGN AND APPROVAL FOR STRUCTURES SUCH AS WALLS AND VAULTS MUST BE PREPARED BY THE APPROPRIATE PROFESSIONAL ENGINEER AND IS NOT A PART OF THESE PLANS. 8. CONTRACTOR SHALL BE RESPONSIBLE FOR HIRING PROFESSIONAL LAND SURVEYOR TO REFERENCE EXISTING MONUMENTS ON OR ADJOINING SITE PREVIOUS TO DEMOLITION OR CONSTRUCTION AND TO RE—ESTABLISH SAID POINTS AT PROJECT COMPLETION. THIS RE—ESTABLISHMENT SHALL BE DOCUMENTED BY RECORD OF SURVEY OR CORNER RECORD AS DESCRIBED IN W.A.C. 332-120. SITE AND GRADING QUANTITIES: LOT TOTAL SQUARE FOOTAGE: 134,074 SF (3.0779 AC) AREA OF WORK: 5,578 SF TOTAL CUT: 140 CY TOTAL FILL: 90 CY THE PROJECT'S TESC PLAN SHEET MUST BE LOCATED ONSITE DURING THE DURATION OF PROJECTS CONSTRUCTION. THE PROJECTS TESC PLAN SHEET MUST REFLECT ALL TESC CHANGES MADE ONSITE DURING CONSTRUCTION AND THOSE PLAN REVISIONS MUST BE INITIALED AND DATED BY THE PROJECTS CERTIFIED TESC REPRESENTATIVE. TEMPORARY DEWATERING: IF A PROJECT REQUIRES TEMPORARY DEWATERING, PLEASE CONTACT THE CITY OF RENTON CUSTOMER SERVICE AT 425-430-7200 TO ESTABLISH A PLAN FOR DEWATERING. pBUSH, ROED & HITCHINGS, INC. N SEAL� f� LAND SURVEYORS & CIVIL ENGINEERS 2009 MINOR AVE. EAST (206) 323-4144 �gSTiING1a Is SEATTLE, Washington 1-800-935-0508 I1 98102-3513 FAX# (206) 323-7135 US BANK EXPANSION 2500 EAST VALLEY ROAD RENTON, WA 98057 C-17003123 N. 1/4 COR. SEC. 30 FNS. 1/2' BRONZE ROD W/PUNdi IN VASE, DOWN 0.3• (SITED 6 -25 -OB (CITY RENTON HORIZONTAL CONTROL 19 11616 0) IN 1 N 170576.87 3 E 1297863.14 ROW MONUMENT E. VALLEY RD. p MD. TACK IN Y CONIC. MIXT IN CASE. p DOWN 1.0' ,n (SITED 6 -25 -OB Da _ v`ITI PROPOSED WATER ALIGNMENT CL I , j S8810'08'E — p23.64— �_— __--_ —_—_l I I L — ADDITION �I 1 I , I 35.00' 136 II 1 II EX WATER 1 II -,, � 00) EASMENT 1 1 , CENTERLINE I I I al EX WATER 1 I 1 I EASEMENT r I I aW u 1 1 �7I I L - EX >I - BUILDING = 11 T F I � III 1 1 AQI II I11 I I II II � LOT 3 �i 2500 EAST VALLEY R \ II 1 IVB � I i — — — — — — — SW 27TH ST ROW MONUMENT E. VALLEY HWY. 11 armW E 3m.1w MD. 1-3/4 111 DISC W/'+ - IN CONC. MON IN CASE, . 3 DOWN 0.4 (SITED B -25 -OB EAST 0.05' OF CALC. INTERSECTION zi 50 25 0 50 700 N SCALE IN FEET 1"=50' JM" AS SHOWN ''�-' CITY OF ZJE RENTON ZJE DATUM Tm Planning/Building/Public Works Dept. NO. REVISION BY DATE APPR Tm PROJECT CONTACTS PROJECT ADDRESS: SURVEYOR: 2500 EAST VALLEY RD. BUSH, ROED & HITCHINGS, INC RENTON, WA 98057 2009 MINOR AVE E SEATTLE, WA 98102 OWNER: CONTACT: TAYLOR SHULTE, P.LS. STRADA DA VALLE, LLC tayors®brhinc.com CONTACT: BRAD MERUNO PHONE: (206) 323-4144 PHONE: (206) 658-0950 5050 1ST AVE S, STE 102 ENGINEER: SEATTLE, WA 98134 BUSH, ROED & HITCHINGS, INC 2009 MINOR AVE E ARCHITECT OF RECORD: TAWA 98102 CORNERSTONE ARCHITECTURAL GROUP CONTACTCT : TED DIMOF, P.E. CON KENMORE, WA 98028 CONTACTS:RICK UTT PHONE: (206) 323-4144 PHONE:tedd@br (20) 3 rutt®comerstonearch.com PHONE: (206) 325-2553 UTILITY CONTACTS SANITARY SEWERS, STORM POWER AND NATURAL GAS DRAINAGE, AND WATER PUGET SOUND ENERGY CITY OF RENTON 10885 NE 4TH STREET, SUITE 1200 1055 SOUTH GRADY WAY PO BOX 97034 RENTON, WA 98057 BELLEVUE, WA 98009-9734 (425) 430-7200 (425) 454-6363 TELEPHONE (888) 225-5773 CENTURY LINK 1600 7TH AVENUE SEATTLE, WA 98191 (800) 244-1111 MMEIAAII111J0I Cl COVER SHEET C2 CITY OF RENTON UTILITY NOTES C3 HORIZONTAL CONTROL AND TOPOGRAPHY PLAN C4 SITE PLAN C5 DEMOLITION AND TESC PLAN C6 TESC DETAILS C7 GRADING AND DRAINAGE PLAN C8 WATER PLAN C9 RENTON STANDARD WATER DETAILS L1.0 TREE RETENTION/LAND CLEARING (TREE INVENTORY) PLAN & IRRIGATION PLAN L1.1 LANDSCAPE PLANTING PLAN AND DETAILS IN COMPLIANCE WITH CITY OF RENTON STANDARDS DEVELOPMENT ENGINEERING SURFACE WATER UTILITY jtjohnson 09/01/2017 rstraka 09/05/2017 REGIONAL FIRE AUTHORITY WATER UTILITY dAPPROVEDho 7 Abdoul Gatour 09/05/2017 0 COVER SHEET `8/18/17 US BANK EXPANSION 2500 EAST VALLEY ROAD RENTON, WASHINGTON 98057 STRADA DA VALLE R-396701