BRH ENGINEERING NOTES:
1. EXISTING UTILITIES AND UNDERGROUND STRUCTURES SHOWN ON THE PLAN ARE BASED UPON
THE BEST AVAILABLE PUBLIC RECORDS AND/OR PRIVATE RECORDS AS SUPPLIED BY THE
PROJECT OWNER AND/OR DATA OBTAINED VERBALLY FROM OWNERS OR OFFICIALS ASSOCIATED
WITH THE PARTICULAR UTILITY. NEITHER THE OWNER NOR THE ENGINEER GUARANTEE THE
ACCURACY OR COMPLETENESS OF THIS INFORMATION AND ASSUME NO RESPONSIBILITY FOR
IMPROPER LOCATIONS OR FAILURE TO SHOW UTILITY LOCATIONS ON THE CONSTRUCTION PLANS.
OTHER UNDERGROUND FACILITIES NOT SHOWN ON THE DRAWINGS MAY BE ENCOUNTERED DURING
THE COURSE OF THE WORK. ALL INVERT ELEVATIONS SHOWN ON THE DRAWINGS SHALL BE
VERIFIED BY THE CONTRACTOR PRIOR TO CONSTRUCTION.
2. IF CHANGED CONDITIONS ARE ENCOUNTERED, THE CONTRACTOR SHALL NOTIFY THE ENGINEER
PROMPTLY OF (1) PREEXISTING SUBSURFACE CONDITIONS DIFFERING FROM THOSE INDICATED IN
THE PLANS, OR (2) PREEXISTING UNKNOWN SUBSURFACE CONDITIONS, OF AN UNUSUAL NATURE,
DIFFERING MATERIALLY FROM THOSE ORDINARILY ENCOUNTERED AND GENERALLY RECOGNIZED AS
INHERENT IN WORK OF THE CHARACTER PROVIDED FOR IN THE CONTRACT. THE CONTRACTOR
AND/OR THE OWNER SHALL MAKE NO CLAIMS TO THE ENGINEER FOR RECOMPENSATION FOR
EXTRA WORK RESULTING FROM CHANGED CONDITIONS UNLESS THE ENGINEER HAS APPROVED
THE WORK IN WRITING. (WSDOT SECTION 1-04.7).
3. THE CONTRACTOR SHALL CALL THE UTILITIES UNDERGROUND LOCATION CENTER FOR FIELD
LOCATION OF ALL UTILITIES AND SHALL NOT BEGIN EXCAVATION UNTIL ALL KNOWN
UNDERGROUND FACILITIES IN THE VICINITY OF THE PROPOSED WORK HAVE BEEN LOCATED AND
MARKED. IF THE UTILITY IS NOT A SUBSCRIBER OF THE UNDERGROUND LOCATION CENTER THEN
THE CONTRACTOR SHALL GIVE INDIVIDUAL NOTICE TO THAT UTILITY. (WSDOT SECTION 1-07.17
APWA SUPPLEMENT).
4. THE CONTRACTOR SHALL TAKE REASONABLE PRECAUTIONS AND EXERCISE SOUND ENGINEERING
AND CONSTRUCTION PRACTICES IN CONDUCTING THE WORK. THE CONTRACTOR SHALL PROTECT
EXISTING PUBLIC AND PRIVATE UTILITIES FROM DAMAGE DURING CONSTRUCTION. IF EXISTING
UTILITIES ARE DAMAGED, THE CONTRACTOR SHALL IMMEDIATELY NOTIFY THE OWNER AND THE
ENGINEER. THE CONTRACTOR SHALL RESTORE THE UTILITY TO ITS EXISTING CONDITION.
(WSDOT SECTION 1-07.17 APWA SUPPLEMENT). THE CONTRACTOR IS RESPONSIBLE FOR THE
MEANS AND METHODS OF CONSTRUCTION FOR DESIGNS SHOWN ON THESE PLANS.
5. WHERE THE PLANS CALL FOR UTILITIES TO BE RELOCATED BY OTHERS, THE CONTRACTOR SHALL
NOTIFY THE UTILITY COMPANY AND COORDINATE HIS WORK SO AS TO AVOID CONFLICTS.
6. ALL EXCAVATION, TRENCHING, SUBGRADE PREPARATION, FILL PLACEMENT AND COMPACTION AND
ALL SOIL WORK IN GENERAL SHALL BE CONDUCTED IN COMPLIANCE WITH THE
RECOMMENDATIONS OF THE PROJECT SOIL ENGINEER AND THE CURRENT GEOTECHNICAL
ENGINEERING REPORT.
7. ENGINEERING DESIGN AND APPROVAL FOR STRUCTURES SUCH AS WALLS AND VAULTS MUST BE
PREPARED BY THE APPROPRIATE PROFESSIONAL ENGINEER AND IS NOT A PART OF THESE
PLANS.
8. CONTRACTOR SHALL BE RESPONSIBLE FOR HIRING PROFESSIONAL LAND SURVEYOR TO
REFERENCE EXISTING MONUMENTS ON OR ADJOINING SITE PREVIOUS TO DEMOLITION OR
CONSTRUCTION AND TO RE—ESTABLISH SAID POINTS AT PROJECT COMPLETION. THIS
RE—ESTABLISHMENT SHALL BE DOCUMENTED BY RECORD OF SURVEY OR CORNER RECORD AS
DESCRIBED IN W.A.C. 332-120.
SITE AND GRADING QUANTITIES:
LOT TOTAL SQUARE FOOTAGE: 134,074 SF (3.0779 AC)
AREA OF WORK: 5,578 SF
TOTAL CUT: 140 CY
TOTAL FILL:
90 CY
THE PROJECT'S TESC PLAN SHEET MUST BE LOCATED ONSITE DURING THE
DURATION OF PROJECTS CONSTRUCTION. THE PROJECTS TESC PLAN SHEET MUST
REFLECT ALL TESC CHANGES MADE ONSITE DURING CONSTRUCTION AND THOSE
PLAN REVISIONS MUST BE INITIALED AND DATED BY THE PROJECTS CERTIFIED TESC
REPRESENTATIVE.
TEMPORARY DEWATERING:
IF A PROJECT REQUIRES TEMPORARY DEWATERING, PLEASE CONTACT THE
CITY OF RENTON CUSTOMER SERVICE AT 425-430-7200 TO ESTABLISH A
PLAN FOR DEWATERING.
pBUSH, ROED & HITCHINGS, INC.
N SEAL� f� LAND SURVEYORS & CIVIL ENGINEERS
2009 MINOR AVE. EAST (206) 323-4144
�gSTiING1a
Is
SEATTLE, Washington 1-800-935-0508
I1 98102-3513 FAX# (206) 323-7135
US BANK EXPANSION
2500 EAST VALLEY ROAD
RENTON, WA 98057
C-17003123
N. 1/4 COR. SEC. 30
FNS. 1/2' BRONZE ROD W/PUNdi IN
VASE, DOWN 0.3•
(SITED 6 -25 -OB
(CITY RENTON HORIZONTAL CONTROL 19
11616 0)
IN 1
N 170576.87 3
E 1297863.14
ROW MONUMENT E. VALLEY RD. p
MD. TACK IN Y CONIC. MIXT IN CASE. p
DOWN 1.0' ,n
(SITED 6 -25 -OB Da _
v`ITI PROPOSED WATER
ALIGNMENT CL
I ,
j S8810'08'E — p23.64—
�_— __--_ —_—_l I I
L — ADDITION
�I
1 I ,
I
35.00' 136 II 1 II
EX WATER 1 II -,, �
00)
EASMENT 1 1 ,
CENTERLINE I I
I al EX WATER 1 I 1
I EASEMENT r I I
aW u 1 1
�7I
I L -
EX
>I - BUILDING = 11 T
F I
� III
1 1
AQI II I11
I I II II �
LOT 3
�i 2500 EAST VALLEY R \ II 1
IVB � I
i
— — — — — — —
SW 27TH ST
ROW MONUMENT E. VALLEY HWY. 11 armW E 3m.1w
MD. 1-3/4 111 DISC W/'+ -
IN CONC. MON IN CASE, . 3
DOWN 0.4 (SITED B -25 -OB
EAST 0.05' OF CALC. INTERSECTION
zi
50 25 0 50 700
N SCALE IN FEET
1"=50'
JM"
AS SHOWN ''�-' CITY OF
ZJE RENTON
ZJE DATUM
Tm Planning/Building/Public Works Dept.
NO. REVISION BY DATE APPR Tm
PROJECT CONTACTS
PROJECT ADDRESS:
SURVEYOR:
2500 EAST VALLEY RD.
BUSH, ROED & HITCHINGS, INC
RENTON, WA 98057
2009 MINOR AVE E
SEATTLE, WA 98102
OWNER:
CONTACT: TAYLOR SHULTE, P.LS.
STRADA DA VALLE, LLC
tayors®brhinc.com
CONTACT: BRAD MERUNO
PHONE: (206) 323-4144
PHONE: (206) 658-0950
5050 1ST AVE S, STE 102
ENGINEER:
SEATTLE, WA 98134
BUSH, ROED & HITCHINGS, INC
2009 MINOR AVE E
ARCHITECT OF RECORD:
TAWA 98102
CORNERSTONE ARCHITECTURAL GROUP
CONTACTCT : TED DIMOF, P.E.
CON
KENMORE, WA 98028
CONTACTS:RICK UTT
PHONE: (206) 323-4144
PHONE:tedd@br (20) 3
rutt®comerstonearch.com
PHONE: (206) 325-2553
UTILITY CONTACTS
SANITARY SEWERS, STORM POWER AND NATURAL GAS
DRAINAGE, AND WATER PUGET SOUND ENERGY
CITY OF RENTON 10885 NE 4TH STREET, SUITE 1200
1055 SOUTH GRADY WAY PO BOX 97034
RENTON, WA 98057 BELLEVUE, WA 98009-9734
(425) 430-7200 (425) 454-6363
TELEPHONE (888) 225-5773
CENTURY LINK
1600 7TH AVENUE
SEATTLE, WA 98191
(800) 244-1111
MMEIAAII111J0I
Cl COVER SHEET
C2 CITY OF RENTON UTILITY NOTES
C3 HORIZONTAL CONTROL AND TOPOGRAPHY PLAN
C4 SITE PLAN
C5 DEMOLITION AND TESC PLAN
C6 TESC DETAILS
C7 GRADING AND DRAINAGE PLAN
C8 WATER PLAN
C9 RENTON STANDARD WATER DETAILS
L1.0 TREE RETENTION/LAND CLEARING (TREE INVENTORY) PLAN
& IRRIGATION PLAN
L1.1 LANDSCAPE PLANTING PLAN AND DETAILS
IN COMPLIANCE WITH CITY OF RENTON STANDARDS
DEVELOPMENT ENGINEERING SURFACE WATER UTILITY
jtjohnson 09/01/2017 rstraka 09/05/2017
REGIONAL FIRE AUTHORITY WATER UTILITY
dAPPROVEDho 7 Abdoul Gatour 09/05/2017 0
COVER SHEET `8/18/17
US BANK EXPANSION
2500 EAST VALLEY ROAD
RENTON, WASHINGTON 98057
STRADA DA VALLE
R-396701