Loading...
HomeMy WebLinkAboutR-39713024• s" I a 5112• 1- R Y Z 1" 3 m LEVEL a W Y m HOOD Z N a MOLD O a..� In' MIN. 6 C' m 3 a MOLD v OPENING HEIGHT �� BOLT -DOWN SLOT SEE NSLOT - SEE �� SLOT- SEE DETAIL I t{ 4" MIN. DETAIL AND NOTE 1 I ❑ `� AND NOTE 1DETAIL 5• AND NOTE 1 0 c C o A 3o J 51. 3 fn Q TOP OF GRATE 2 1(2` DIA . H 4 � J LL.I SEE NOTE 3 5' - FRAME 20 � 20 N L o p�p4p 5" O o � [EJ O�QQO�OLL =L °z o 5" o O DETAIL SECTION O pa���QpQp 3, n Q�4�QpQ�Q O OUTFACE TO STREAM DUMP NO POLLUTANT CATCH BASIN IUTFALL TD STREAM DUMP NO POLLUTANT 29•MIN. (-0�) =3" TOP B SECTION OB TOP SECTION O w TOP SECTION 1" MIN. 20 1/a" (= 0.25') s Typ GRATE � � � C NOTES U L 1 Provide two slots in the cover that are vertically aligned O o with the holes in the frame.Location of bolt -down slots z with among different manufacturers. NOTE 4 4 3l4" 1 1 /2" yq• SEE N :34'(WIDE SIDE) g (TYP.) 2. Alternative reinforcing designs are acceptable in Z CATCH BASIN TYPE 1 7 OR 8 EQUAL SPACES SEE NOTE � lieu of the rib design. '� 24• mP') = 40" (WIDE SIDE) H:'•� •• CATCH BASIN TYPE 1L 3. Refer to Standard Specification 9-05.15(2) for additional uP5 DIRECTION OF FLOW 4 EQUAL SPACES 4 EQUAL SPACES ON requirements O =-7--. SEE NOTE 2 4. For Frame details, see City of Renton o SECTION O Standard Plan 204.00. LSECTION O __ Z SEE NOTE TOP VIEW SECTION O 1/2 SECTION 0 O FRAME DETAIL O NOTES 1. The asymmetry of the Combination Inlet shall be considered when 1 1/4" V calculating the offset distance for the catch basin. See SECTION A. Z 2. The dimensions of the Frame and Hood may vary slightly among dif- 7 O ferent manufacturers. The Frame may have cast features intended 5• CURB OR CURB AND GUTTER to support a grate guard. Hood units shall mount outside of the g,n• Op000� MATCH TOP OF HOOD Frame. The methods for fastening the Safety Bar / Debris Guard Rod 1/2 TO TOP OF CURB (TYP.) O to the Hood may vary. The Hood may include casting lugs. The top ®p O ®p ®gyp A ' 0 ® ®Q 0 ®� G /L YL of the Hood may be cast with a pattern. HOOD 3. Attach the Hood to the frame with two 3/4" x 2" hex head bolts, nuts, 4" 4- 3/q• DIAM. HOLE O®®�OOpO�®®�pOOOOOp DO NOT INSTALL and oversize washers. The washers shall have diameters adequate 1 1/z" 1/2" DIAM. HANDLE O�p®OODOpO®00®�O®� BOLT -DOWN SLOT DETAIL BOLT -DOWN SLOT DETAIL W SAFETV BAR/ DEBRIS GUARD to assure full bearing across the slots. pO®�®0®OOGooO® x QOO O�®OOO�O SEE NOTE 1 ���\SEE NOTE 1 20" 24" VANED GRATE 4 When bolt -down grates are specified in the contract, provide two SECTION cO 1 �Op00OOp� NOTES Y holes in the frame that are vertically aligned with the grate slots. ®O®� NOTES FRAME Tap each hole to accept a 5/8" x - 11 NC x 2" alien head cap screw. OOG 1• Provide two slots in the grate that are vertically aligned . . Location of bolt -down holes varies among different manufacturers. with the holes in the frame. Location of bolt -down slots Provide two slots in the grate that are vertically aligned See BOLT- DOWN DETAIL varies among different manufacturers. 1. with the holes in the frame. Location of bolt -down slots varies among different manufacturers. 5. Only ductile iron Vaned Grates shall be used. ISOMETRIC ISOMETRIC BOLT -DOWN SLOT DETAIL ISOMETRIC z. Refer to Standard Specification 9-05.15(2) for additional z. Refer to Standard Specification 9-05.15(2) for additional requirements. J 6. This plan is intended to show the installation details of a manufao SEE NOTE 1 requirements. 3. Use only on sags and vertical curbs locations. tured product. It is not the intent of this plan to show the specific 3. Unless otherwise specified, vaned grates shall be used with standard frame ISOMETRIC VIEW details necessary to fabricate the castings shown on this drawing. in the travel way, gutter or shoulder. vaned grates shall not be located 4. Unless otherwise specified, vaned grates shall be used with standard frame within crossroads. Use vaned grates along rolled curbs. in the travel way, gutter or shoulder. vaned grates shall not be located within crossroads. Use vaned grates along rolled curbs. o~�Y STD. PLAN - 203.00 o~�Y �,{ STD. PLAN - 204.10 o~�Y �� STD. PLAN - 204.20 o~�Y �� STD. PLAN - 204.30 PUBLIC WORKS OPEN CURB FACE n PUBLIC WORKS RECTANGULAR SOLID n PUBLIC WORKS RECTANGULAR n � PUBLIC WORKS RECTANGULAR BI-DIRECTIONAL ;P- + DEPARTMENT FRAME AND GRATE DEPARTMENT METAL COVER � DEPARTMENT VANED GRATE - DEPARTMENT VANED GRATE �N f INSTALLATION DETAIL MARCH 2O08 FNTO MARCH 2O08 �N fO MARCH 2O08 �N fO MARCH 2008 M0 W r O O O 1/2" [13mm] LETTERING NOTE: Y a O.D. limits of pipe W (sae note 4) D• compaction 1 . SEE SEC. 5.04. KCRS. BOLTHOLES - 3 PLCS EQUALLY SPACED 120• io 3' max. Y m p limit cr pipe one APART ON 23 1H6' (586mm) DIA B.C. #6 BARS @ 7" SPACING TS - 12"(TYP•) 1'-0 madenal c ��zI�ceT x turovaMOf for flexible 2. INSTALLATION OF N.D.C.B.U. MUM pipe (see ® s �w note6) INCLUDING CONSTRUCTION OF 21"x24", Cc O.D. BASE WILL BE DONE BY THE 24- DIAM, 48" DIAM. 0.15 O.D. min. NOTE: a` OR54^DIAM. HOLE U.S. POSTAL SERVICE. CITY LOGO LIDS NOT y limits of pipe �P') compaction Q 0.850.D. min. R E N T O N ALLOWED ON PRIVATE 2" PROPERTY/SYSTEM �� 12 eveldation $ , n r n r a AHEAD OF THE CURVE ® Q 1"MIN. iA for pi bedding ,�"A4gx for pipe bedding Brevel backfill for 1 -4 2 -7 MAX. MIN. 5'-0" CLEAR WIDTH £ °m foundations when specified 84" Or 98" FLAT SLAB TOP ,2• • A= 4 min. 27" I.D. and under P8' min., over2T I.D. DRAIN PREFABRICATED LADDER A. Metal and Concrete Pipe - (1)1" (25mm) >: Bedding for Flexible Pipe L - - - J Js DIA PICKHOLE COVER BOTTOM VIEW OQ #5 BARS O 6" SPACING span span span - max max 3' max 1 114" [32mm] LETTERING Flexible Pipe NOTES: � - - 1. Provide uniform support under barrels. PLAN VIEW ° 12" MIN. 2. Hand tamp under haunches. 20" x 24" 1 3. Compact bedding material to 95% max. density; directly- 24" DIAM., 48" DIAM. al over pipe, hand tamp only. I OR 54" DIAM. HOLE 0.15 rise min. 4. See "Excavation and Preparation of Trench" in sanitary 2' (TYP TYPICAL ORIENTATION � 25" DIA. (3) BLT Soc. (ALLEN HEAD) r m sewers section of the standard WSDOT/APWA - - - MOUNT ON PEDESTAL PROVIDED 5/8"-11X1.53S �- FOR ACCESS AND STEPS limits of i [635mm] 1• 1 pipe specifications for trench width "W" and trenching [25mm] RUBBER WASHER 1 compaction D.85 rise in. WITH N . D . C . B . U . UNIT. -[ 1"MIN. STEP options. The pipe zone will be the actual trench width. 3/4' [Isom] 72" FLAT SLAB TOP ravel back811 for The minimum concrete width shall be 1 2 I.D. = 18". gravel backfill 9 5. Trench backfill shall conform to "Backfilling Sewer 6" for pipe bedding foundations when specified Trenches" in the sanitary sewers section Of the ANCHOR B 0 LT TT 2[� WSDOT/APWA standard specification, except that 3/8 r' X FULL DEPTH PATTERN PER 21/2• I rocks or lumps larger than I" per foot of pipe diameter EXPANSION JOINT N.D.C.B.U. e 3/4^ [64mm] B. Pipe - Arch Installation shall not be used in the backfill material. [222mm] #4 BARS @ 6"SPACING Q 6. See "Bedding Material for Flexible Pi inaggregates PEDESTAL TYP ✓. 9 Pe" section of the WSDOT/APWA standard specifications SIDEWALK TEMPLATE. COVER SECTION VIEW for the material specifications. Rigid Pipe NOTES: • " 20' x 24" OR 1. Pipe compaction limits shown on this plan are for pipe ' EON BOLTING DETAIL 24" DIAM. HOLE construction in an embankment. For pipe construction 4 2• (TYP.) 48"MIN. I I in a trench, the horizontal limits of the pipe compaction i r h zone shall be the walls of the trench. 261/2' DIA 1" MIN 2. All steel and aluminum pipe and pipe -arches shall be • < ^ [673mm] 1 2 M" MAX. ECCENTRIC CONE SECTION installed in accordance with design A. SEE NOTE N 0 . 2 48" S4" Or 60" FLAT SLAB TOP 3. Concrete pipe with elliptical reinforcement shall be ® Backfill material placed in 0.5' loose layers and SEE NOTE 251/4" DIA r r installed in accordance with design A. compacted to 95% maximum density. N O 2 [641mm] 1 1/16" 4. Concrete pipe, plain or with circular reinforcement, shall be installed with design A. Method B p ci compaction (WSDOTlAPWA) [27mm] standards specifications.) (Bmm) DIA 5. O.D. is equal to the outside diameter of a pipe or the p ) 1 -6' • NEOPRENE GASKET outside span of pipe -arch. The dimensions shown as 1-6 3p. O.D. with 3' maximum shall be O.D. until O.D. equals 1/4• LA 3'; at which point 3' shall be used. [152mm] loom] �mm] 0". for diameters 12"ter through 42" and spans through Min. den SIDE VIEW 1 � 5 50". 2'-0" for diameters greater than 42" and spans Pipe Size between FRONT VIEW greater than 50". barrels 23 3I8' DIA CL OPEN 6" OR 12' [16mm] [594mm] MI ; y 12" to conc., LCPE, CMP circular pipe 3" diam. / 2 NEIGHBORHOOD MAILBOX UNIT 27 5/16• DIA `I (diameter) [R3mm] �NE #3 BAR HOOP 'I , NOT TO SCALE [894mm] - 1!5" T 102" to 180" 48" 341/8" DIA O #3 BAR HOOPS OFOR 12"O 4" 6� pipe - arch 18" to 36" 12" GASKET GROOVE DETAIL [867mm] CIRCULAR ADJUSTMENT SECTION metal only 43" to 142" span / 3 NOTES RECTANGULAR ADJUSTMENT SECTION (span) 148" to 199" 48" FRAME SECTION VIEW IN COMPLIANCE WITH CITY OF RENTON STANDARDS ALL COVERS SHALL BE LOCKING LID PER EASTJORDAN IRON WORKS INC. No. 3717C1 OR APPROVED EQUAL. 1.0 As an acceptable alternative to rebar, wire mesh having a minimum area of 0.12 square inches per foot may be used for adjustment sections. STD. PLAN - 204.50 o~�Y � STD. PLAN - 204.80 1� STD. PLAN - 220.00 PUBLIC WORKS STORM ROUND FRAME AND COVER n PUBLIC WORKS MISCELLANEOUS DETAILS FOR i PUBLIC WORKS PIPE COMPACTION DEPARTMENT ' DEPARTMENT DRAINAGE STRUCTURES + DEPARTMENT DESIGN AND BACKFILL MARCH 2O08 "PENT MARCH 2O08 � ,T MARCH 2O08 _ Call 2 Working Days Before You D' g y Dig 811 Utilities Underground Location Center (ID,MT,ND,OR,WA) DOES NOT N C L U D E A S B U �T N E O R M AT O N 0 FIRST SUBMITTAL ESM 08/30/171 SURVEYED: SCALE: NTS VERTICAL: NAVD 83/1 HORIZONTAL: NAD 1983/1991 DATU M •- CITY OF qqRENTON Planning/Building/Public Works Dept. EARLINGTON TOWNHOMES DETAILS UTILITY PERMIT # 01 03 18 / / 1 SECOND SUBMITTAL ESM 11/15/17 DESIGNED: Poi 2 THIRD SUBMITTAL ESM 01/03/18 PAGE:FIELDOOK: PAGE` DRAWN: ONE INCH DRAWING NO: DT-04 CHECKED: AT FULL SCALE IF NOT ONE INCH SCALE ACCORDINGLY N 0. REVISION BY DATE AP P R APPROVED: SHEET: +O OF: 3 55 R- 397130