PAVEMENT BASE
I
SAND LAYER (fF REQUIREDy
SEE NOTE 4
I I
12" MIN ABOVESEASONAL HIGH
GROUNDWATER OR
HYDRAULICALLY
SUBGRADE SEE NOTE 3
v
RESTRICTIVE LAYER
PERVIOUS CONCRETEIPOROUS ASPHALT
MINIMUM MATERIAL THICKNESS Oft
RESIDENTIAL STREETSAND
PEDESTRIAN
ALLEYS
v
PERVIOUS
POROUS
PERVIOUS
POROUS
LAYER
MATERIAL TYPE'
CONCRETE
ASPHALT
CONCRETE
ASPHALT
(IN)
ON)
)IN)
(IN)
O'E
PERMEABLE �JIVERIENT: SEE NOTE 1
8
6
'4
i Fi I
CHOKER COURSE
C
2
0_
AGGREGATE BASE SEE NOTE 2
8
6
6
NOTES:
1 PERMEABLE PAVEMENT THICKNESSES LISTED FOR POROUS ASPHALT INCLUDE WEARING COURSE ANDASPN,AILT TREATED PERMEABLE BASE
(ATPB1 WHEN UTILIZED CHOKER COURSE REQUIRED WHEN ATPB IS USED
2 RUNOFF STORAGE REQUIREMENTS MAY REQUIRE A THICKER AGGREGATE BASE. HYDRAULIC MODELING RESULTS SHOWING THE REQUIRED
AGGREGATE BASE THICKNESS FOR STORMWATER CONTROL MUST BE SUBMITTED
3 PREPARE AND PROTECT SUBGRADE PER APWA GSP 2-06 3(31 SUBGRADE FOR PERMEABLE PAVEMENTS COMPACT TO A DEPTH OF 6 TO 90%-92%
OF MAXIMUM DENSITY PER WSOOT 2-03 3(141D OVERCOMPACTED SUBGRADE SHALL BE SCARIFIED TO B' MIN ANDRECOMPACTED
4 PERMEABLE PAVEMENT SHALL BE DESIGNED WHERE THE SOIL BENEATH THE BMP MEETS A MINIMUM ORGANIC MATTER CONTENT OF 1 0`Y AND l
A MINIMUM CATION EXCHANGE CAPACITY OF 6 MILL!EQUIVAL£NTS PER 100 GRAMS A 6 INCH SAND LAYER MUST BE INCLUDED IN THE DESIGN f
BENEATH THE PERMEABLE PAVEMENT IF THE SOIL DOES NOT MEET THESE PROPERTIES
GENERAL NOTES:
REFEk'TO WSDOT LOCAL AGENCY GENERAL SPECIAL PROVISIONS (GSP%) DIVISIONS 2-9 APWA GSP% AND MOOT STANDARD SPECIFICATIONS
POROUS HMA SHALL CONFORM TO REQUIREMENTS OF APWA GSP 5-04
,3- PAVEMENT BASE SMALL BE INSTALLED PER APWA GSP 4-04.3(5) SHAPING AND COMPACTION
4 PERMEABLE ASPHALT TREATED BASE (PATE) SHALL CONFORM TO THE REQUIREMENTS OF APWA GSP 4-SA2 CRUSHED SURFACING CHOKER II
COURSE (CSCC) SHALL CONFORM TO THE REQUIREMENTS OF APWA GSP 4-04 2(9.03 9(211 CPU
5 PERMEABLE BALLAST SHALL CONFORM TO THE REQUIREMENTS OF APWA GSP 4-04 299-03.9(2)) Opt1
I I
6 MINIMUM UTILITY SETBACKS AND PROTECTION MEASURES MUST CONFORM TO CURRENT CITY STANDARDS AND OTHER UTILITY PROVIDER
REQUIREMENTS REFER TO THE CITY OF RENTON SURFACE WATER DESIGN MANUAL AND STANDARD PLANS 26510 AND 26520
T PERMEABLE PAVEMENT SHALL BE DESIGNED OR REVIEWED BY A LICENSED ENGINEERING GEOLOGIST OR GEOTECHNICAL ENGINEER FOR ALL
APPLICATIONS. PAVEMENT DESIGNS MUST BE PREPARED BY AN ENGINEER LICENSED IN WASHINGTON STATE
8 ACCEPTANCE TESTING FOR SIDEWALKS, PATHS AND VEHICULAR PAVEMENT LESS THAN 2,000 SF SHALL BE AS FOLLOWS PAVEMENT SHALL BE
PERMEABLE ENOUGH TO ABSORB WATER AT A MINIMUM RATE OF 20 INCHES PER HOUR IMMEDIATELY AFTER SURFACE HAS BEEN WETTED
CONTINUOUSLY FOR AT LEAST 10 MINUTES APPROVAL WITH 5 GALLON BUCKET TEST, WATER TRUCK. OR ASTM C1701 USING A 12-INCH RING
SEALED AT THE PAVEMENT SURFACE
9 ACCEPTANCE TESTING FOR ROADWAYS AND PARKING AREAS OF 2.000 SF OR GREATER SHALL HAVE A MINIMUM INFILTRATION RATEOF 140;
IIWHR PER ASTM C1701 AND APWA GSP 5-04.3 AND 5-063161
10 ROADWAYS. DRIVEWAYS, AND PARKING LOTS SUBJECT TO VEHICLE LOADING SHALL MEET STRUCTURAL REQUIREMENTS OF CITY OF RENTON
TRANSPORTATION DEPARTMENT STANDARDS FOR EQUIVALENT NON -PERMEABLE PAVEMENT TYPES
11 REEFER TO THE CITY OF RENTON SURFACE WATER DESIGN MANUAL 1SWOM)FOR ADDITIONAL REQUIREMENTS PER SWDM C 2 7
12 FOR PERMEABLE PAVEMENT MSTALLATIONS ON SLOPES GREATER THAN 5%. CHECK DAMS AREA REQUIRED PER STD PLAN 201 20
UNLESS OTHERWISE NOTED, DRAWING IS NOT TO SCALE (NTS)
PERMEABLE PAVEMENT MATERIAL STD, PLAN - 261.10
_•® DEPARTMENT PUBLIC WORKS SECTIONS - PERVIOUS CONCRETE AND A Y
�L� Omw At
POROUS ASPHALT;
ICONI'ROI J31h1? ('YP)
(PERV OJS CONCRETE ONLYI DESIGNER-] SPECIFY
EPACIHO
DESIGN VVArER SURFACE
I.FVAT!ON CIDN-R:]_LE7 'D%`JAX. SIOPE MIN),CHE (T10A`,1
av CUTLET I C�EARAN'CE _
SEE PERMEABLE
PAVEMENT SECTION r
S'i) PI AN 2611C r 12 A I�
jGONTRO_LEC OENSI-Y FILL ( 1 iV
SUB LkFA'E CHECK [.AM Pi R UF_SIGNER F'f ` 1
LWSI 71 SF .,T IOr.2 05 3, P,E - 3" MIN K=Y
,jYF) CFECKCAM REQUIRED
12"M1"N CHECK CAN HFIGHT 1
(FOR SLCPE S-ErPER THAN 5i'6 OFS GNFR 1
TOSPECIFY SUBGRADE PEP SLDTTEO LNCEFDRAN-1� d
STOPIAN?I] IC 6"LMIN 3EQDiNG SELNOTE 2
I`
CONTROLLED DENSITY FILL SUBSURFACE CHECK DAM!
CONTROL, JDINT(TYP I SPACING
(PERVIOUS CONCRETE DNLYi u
._. G ER'TOSPECIFY
SiG
DESIGN'N'ATLR SURFACE ACING 1,
(ELEVATION Co^!TROLL FO BY ,
(:OUTLET 1C% MAX S_OPE
- -- _ T MIN CHECKOAhI
C EARANCE
SEE PERMEABLE 1
PAVEDM ENT SEC71Ch
STD PLAN 761 1C
N:. 7
-� CC'JFR .---_.J S
4 I
1 - � t
'§U63RADP PFR STGPIAN 251 10 DES'GNER TC SPEi?FY }r , zT L
COMMERCIAL CONCRE'E 4 h'I'J SUHSUk1ACF C1-.FC{ J i,
SUBSL'RFACE CHECK DAV PER DAM HFIGH'
'NSCOT SECTION E,02 3(21B I'YP ''
CHECKDAH REQJ RED FOR5L0'--ED UF, DER,RALN;.`L
r MI•J EE`4O1E.2 ]'
SLOPE SILLPER Tti{A'NA%j BEC'DIN_
CONCRETE-6ANQ SIl URFMICE CHECK DAM
C! FA.NDLIT PER1S DD ot1T! FT Fl FVATION. l+
P-AN 22530 0, 1-k .FVFL CONTRCLL FD BY CF. S!GNER TO SPECIFY, o
^UTLE- ELEV AT C'J
SEE PERMEABLE TYPE IL tl) R 3T16 RLALLA
PAVLMENT S-C'ICN - 00 3 OR FISHER STRURT;IJR'Fr
STD "-AN2E1 lO 1 MIN i i NIN 3 M#A �'AITHAP) QVAL� J
f � I
I
IIIIIIIIIIIIIIIIIIIIIUIIIIIIIIII 1111111111111111111111111111111111111 REMOVABLE PLUS
FDR MAINTENANCE •%
17 MIN
,1rJ0FRGRAIN AGGREGATE SIN-ARY TEL CLEAR
SEE NOTE( WIT PT NAI IlJll
SLOTTEOUNDFRDRAIN PIPE RISER -APE - -
SEE NOTE 2 �y OUTFLOW
SUBGRADE PER $TO PLAN 261 1C
12' MIN SUMP
UNDERDRAIN AND OVERFLOW
NOTES: CONTROL STRUCTURE WITH RISER
1 UNOFR:1RAIN A(,GRF,,ATF FBA.( MPET SPECIFICATION IN THE CITY OF REN`ON SURFACE WATER DESIGN MANUAL (S'4DM) TABLE C2 7 1A PERMEABLE BALLAST PER
5 P F C, 9 03 9L2;
2 JNDERDRAIN TO BE 6' MIN (PRIV.AT E) 6" MIN. ;PUBLIC! SLOT TCD PVC PERASTM017ASSCH 40 S-OTS PER SWDM C 2 7'. OF SWDM SLOPE PIPE AT 0 5%MIN UNLESS
OTHERIOASE SPECIFIED PROVIDE ONE CLEA'JCU5 MIN PER 1C0 FEET OF UNCERDRAIN AND AT EACH END SEE STD PLAN 226 C0
3 JNJERL'RAIN SHALL BF PLACED IN FILTER MATERIAL PER SPECI.PICATIDNS IN TABLE C 2 71A CIF SWDM PPE WILL HAVE A MINIMUM COVER DEPTH OF 12* ANC BED] NG
DFPTH OF S'
GENERAL NOTES:
1 �CCA E LNDERDRAIN BELO'N 51RL'Cf I PAVFMFNI HAS- CFP'H U.L_S5 '•TkE RSVISE `:OT=D, DRAWING ISNCTT05;ALIE NTS1
STD. PLAN - 261.20
• PUBLIC WORKS PERMEABLE PAVEMENT: SUBSURFACE P ROVED 1
7", DEPARTMENT CHECK DAMS AND UNDERDRAINvastv �rro ._ S ►
o,yt ATE
Call 2 Working Days Before You Dig
811
Utilities Underground Location Center
(ID,MT,ND,OR,WA)
STORMFILTER CATCHBASIN DESIGN NOTES
STORMFILTER TREATMENT CAPACITY IS A FUNCTION OF THE CARTRIDGE SELECTION AND THE NUMBER OF CARTRIDGES. 2 CARTRIDGE CATCHBASIN
HAS A MAXIMUM OF TWO CARTRIDGES. SYSTEM IS SHOWN WITH A 27" CARTRIDGE, AND IS ALSO AVAILABLE WITH AN 18" CARTRIDGE. STORMFILTER
CATCHBASIN CONFIGURATIONS ARE AVAILABLE WITH A DRY INLET BAY FOR VECTOR CONTROL.
PEAK HYDRAULIC CAPACITY PER TABLE BELOW. IF THE SITE CONDITIONS EXCEED PEAK HYDRAULIC CAPACITY, AN UPSTREAM BYPASS STRUCTURE IS
VANED INLET GRATE REQUIRED.
(SOLID COVER CONCRETE COLLAR
OPTIONAL) AND REBAR TO MEET
HS20 IF APPLICABLE BY CARTRIDGE SELECTION
CONTRACTOR CARTRIDGE HEIGHT 27" 18" 18" DEEP
MINIMUM HYDRAULIC DROP (H) 3.05' 2.3' 3.3'
SPECIFIC FLOW RATE (gpm/sf) 2 gpm/W 1 1 gpm/ft2 2 gpm/ft' I gpm/ft' 2 gpm/ft2 1 1 gpm/ft2
II CARTRIDGE FLOW RATE (gpm) 22.5 1 11.25 15 1 7.5 15 1 7.5
A PEAK HYDRAULIC CAPACITY 1.0 1.0 1.8
aI d IL°. INLET PERMANENT POOL LEVEL (A) 1'-01. 2'-0"
II e 8 II o OVERALL STRUCTURE HEIGHT (B) 4'4" T-9" 4'-9"
is
II
II II a ° z GENERAL NOTES
�� 1. CONTECH TO PROVIDE ALL MATERIALS UNLESS NOTED OTHERWISE.
IWI ° 2. FOR SITE SPECIFIC DRAWINGS WITH DETAILED STORMFILTER CATCHBASIN STRUCTURE DIMENSIONS AND WEIGHTS, PLEASE CONTACT YOUR
a CONTECH ENGINEERED SOLUTIONS LLC REPRESENTATIVE. www.ContechES.com
3. STORMFILTER CATCHBASIN WATER QUALITY STRUCTURE SHALL BE IN ACCORDANCE WITH ALL DESIGN DATA AND INFORMATION CONTAINED IN
THIS DRAWING.
ACCESS COVER 4. INLET SHOULD NOT BE LOWER THAN OUTLET. INLET (IF APPLICABLE) AND OUTLET PIPING TO BE SPECIFIED BY ENGINEER AND PROVIDED BY
CONTRACTOR.
2'-4" Z-4" 2'4" 5. STORMFILTER CATCHBASIN EQUIPPED WITH 4 INCH (APPROXIMATE) LONG STUBS FOR INLET (IF APPLICABLE) AND OUTLET PIPING. STANDARD
INSIDE RIM INSIDE RIM ~ INSIDE RIM OUTLET STUB IS 8 INCHES IN DIAMETER. MAXIMUM OUTLET STUB IS 15 INCHES IN DIAMETER. CONNECTION TO COLLECTION PIPING CAN BE MADE
USING FLEXIBLE COUPLING BY CONTRACTOR.
T-1" 6. STEEL STRUCTURE TO BE MANUFACTURED OF 1/4 INCH STEEL PLATE. CASTINGS SHALL MEET AASHTO M306 LOAD RATING. TO MEET HS20 LOAD
COLLAR OUTSIDE RIM RATING ON STRUCTURE, A CONCRETE COLLAR IS REQUIRED. WHEN REQUIRED, CONCRETE COLLAR WITH QUANTITY (2) #4 REINFORCING BARS TO
BE PROVIDED BY CONTRACTOR.
PLAN VIEW 7. FILTER CARTRIDGES SHALL BE MEDIA -FILLED, PASSIVE, SIPHON ACTUATED, RADIAL FLOW, AND SELF CLEANING. RADIAL MEDIA DEPTH SHALL BE
7-INCHES. FILTER MEDIA CONTACT TIME SHALL BE AT LEAST 37 SECONDS.
8. SPECIFIC FLOW RATE IS EQUAL TO THE FILTER TREATMENT CAPACITY (gpm) DIVIDED BY THE FILTER CONTACT SURFACE AREA (sq ft).
INSTALLATION NOTES
A. ANY SUB -BASE, BACKFILL DEPTH, AND/OR ANTI -FLOTATION PROVISIONS ARE SITE -SPECIFIC DESIGN CONSIDERATIONS AND SHALL BE SPECIFIED BY
ENGINEER OF RECORD.
B. CONTRACTOR TO PROVIDE EQUIPMENT WITH SUFFICIENT LIFTING AND REACH CAPACITY TO LIFT AND SET THE CATCHBASIN (LIFTING CLUTCHES
PROVIDED).
C. CONTRACTOR TO TAKE APPROPRIATE MEASURES TO PROTECT CARTRIDGES FROM CONSTRUCTION -RELATED EROSION RUNOFF.
fXQ
STORMFILTER
CARTRIDGE TYP. _
FILTRATION
BAY INLET TYP.
FLOW _
KIT TYP.
CLEANOUT
ACCESS PLUG
ON WEIR WALL
6,-9„
OPTIONAL SLOPED LID FLOATABLES BAFFLE
2'_8" - 2'-0" - CORNER ELEVATIONS TO BE
SPECIFIED BY ENGINEER
PERMANENT
B POOL LEVEL
- - - - + FINISHED GRADE -
IIII=,11111,IL1_I- �O O
- - - - - - - - - -
i LIFTING EYE
(TYP. OF 4)
PERMANENT FILTRATION WEIR WALL =
POOL ELEVATION BAY INLET
j � 1 5 FLOW
CARTRIDGE INLET STUB OUTLET STUB
SUPPORT TYP. (OPTIONAL)
- OUTLET PIPE
FROM FLOWKIT
CATCHBASIN FOOT 2'-0"
B (TYP. OF 4) INSIDE CATCHBASIN FOOT
(TYP. OF 4)
2'-Dy"
OUTSIDE
SECTION A -A SECTION B-B
me slo�wal� manaeeme"
StormFilter®
2-CARTRIDGE DEEP CATCHBASIN
STORMFILTER DATA
STRUCTUREID
XXX
WATER QUALITY FLOW RATE cfs)
X.XX
PEAK FLOW RATE <1.8 cfs
X.XX
RETURN PERIOD OF PEAK FLOW
rs
XXX
CARTRIDGE FLOW RATE pm
XX
MEDIA TYPE CSF, PERLITE, ZPG, GAC, PHS
XXXXX
RIM ELEVATION
I XXXXX
PIPE DATA:
I.E.
DIAMETER
INLET STUB
XXX.XX'
XX"
OUTLET STUB
XXX.XX'
XX"
CONFIGURATIONS OUTLET
O 0
OUTLET INLET OUTLET
OO INLET INLET OO
INLET INLET
SLOPED LID
YES\NO
SOLID COVER
YES\NO
NOTES/SPECIAL REQUIREMENTS:
STORM FILTER DATA TABLE
STRUCTURE
I.D.
AREA
PUBLIC/
PRIVATE
# OF
CARTRIDGES
WATER QUALITY
FLOW RATE
PEAK
FLOW RATE
RETURN
PERIOD
CARTRIDE
FLOW RATE*
MEDIA
TYPE
RIM
ELEV.
INLET
ELEV.
INLET
DIA.
OUTLET
ELEV.
OUTLET
DIA
SLOPED
LID?
SOLID
COVER?
1
ALLEY B
PRIVATE
2
0.034 CFS
0.064 CFS
50 YR
0.067 CFS
CSF
245.37
N/A
N/A
241.12
8"
NO
NO
2
ALLEY A
PRIVATE
2
0.038 CFS
0.071 CFS
50 YR
0.067 CFS
CSF
245.40
N/A
N/A
241.15
8"
NO
NO
3
ROAD A
PUBLIC
2
0.023 CFS
0.042 CFS
50 YR
0.067 CFS
CSF
249.18
244.93
8"
244.93
8"
NO
NO
4
ROAD A
PUBLIC
2**
0.076 CFS
0.141 CFS
50 YR
0.134 CFS
CSF
262.01
258.01
8"
258.01
8"
NO
NO
5
ALLEY D
PRIVATE
2
0.038 CFS
0.071 CFS
50 YR
0.067 CFS
CSF
266.24
N/A
N/A
261.99
8"
NO
NO
6
ALLEY C
PRIVATE
2
0.034 CFS
0.064 CFS
50 YR
0.067 CFS
CSF
266.16
N/A
N/A
261.91
8"
NO
NO
7
ALLEY E
PRIVATE
2
0.034 CFS
0.064 CFS
50 YR
0.067 CFS
CSF
279.07
N/A
N/A
274.82
8"
NO
NO
8
ROAD A
PUBLIC
2
0.027 CFS
0.049 CFS
50 YR
0.067 CFS
CSF
237.38
233.88
8"
233.88
8"
NO
NO
NOTES:
1. UNLESS OTHERWISE NOTED USE 18" CARTRIDGES.
2. ALL STORM FILTER UNITS SHALL BE PROVIDED WITH 1'
CONCRETE COLLAR W/#4 REBAR ALL AROUND TO PROVIDE
HS-20 LOAD CAPACITY.
3. SEE PLAN VIEW FOR PIPE CONFIGURATION AND UNIT
ORIENTATION.
4. WATER QUALITY FLOW RATE IS FOR 2-4 YEAR RETURN
PERIOD.
5. PER CONTECH SUPPORT, MAXIMUM RIM TO INVERT
DISTANCE (DIMENSION 'H') IS 4.25'. MAXIMUM OVERFLOW
CAPACITY IS ABOUT 1.0 CFS.
6. FOR TECHNICAL INFORMATION OR VERIFICATION, CONTACT
CONTECH, STEPHANIE JACOBSON (503) 258-3185.
* 15 GPM CARTRIDGE = 0.0334 CFS
2 CARTRIDGE UNIT CAPACITY = 0.067 CFS
** USE 27" CARTRIDGE
DOES N O T N C E U D E
A S B U ET N E O R M AT O N
0 FIRST SUBMITTAL
ESM
08/30/17
SURVEYED:
SCALE:
NM
VERTICAL: NAVD 1988
HORIZONTAL: NAD 1983/1991
DATU M
1 SECOND SUBMITTAL
ESM
11/15/17
DESIGNED:
� MG
PD
2 THIRD SUBMITTAL
ESM
01/03/18
DRAWN:
ONE INCH
CHECKED: :
AT FULL SCALE
IF NOT ONE INCH
SCALE ACCORDINGLY
N 0.
REVISION
BY
DATE
AP P R
APPROVED:
Aoffl%k
CITY OF
RENTON
•
Planning/Building/Public Works Dept.
IN COMPLIANCE WITH CITY OF RENTON STANDARDS
EARLINGTON TOWNHOMES
DETAILS
UTILITY PERMIT #
01/03/18
FIELDBOOK:
PAGE:
DRAWING NO:
DT-05
SHEET: OF:
31 55