Loading...
HomeMy WebLinkAboutW-397106Z L, I� A PORTION OF THE NE 1/4 OF SEC 13, TWP 23 N., RGE 4 E, W.M., KING COUNTY, WASHINGTON SEE SHEET WA-05 FOR CONTINUATION M 1-00 2 0011 3 4 5 STA. 0+02.50, 5.00' LT. \ \ ND CAP (MJ) L- I \ W 2" LOW OFFF ASS Y I \ 1 /CO C. BI OCKING I I � 'fC� 8"0 D.I. W.M. �I 178.4' W I� 292 r7i - Li '14 t 1 0 V/ 9� o : \ \ +00 \\ 0 r I ALLEY E Z STA.=70+00.00, ALLEY E 24' _20' END OF ROAD IMPROVEMENTS - F I , 26In , \ \\ \ 0 1 " WATER SERVICE AND METER PER 1" WATER METER SERVICE ~ COR STANDARD PLAN 320.1 (TYP.) ARMOUR CAST 12x24x(8 / �� \-�` �\ WITH 2" A.R.M. HOLE TYP.) -\ -� \ h 7 8 9 10 11 - - - \ I \ o Q Ld u \CENTE n� ^I_II -DcE- LL.I �. S 7. Er A\V A ROAD A \ � < Call 2 Working Days Before You Dig 811 Utilities Underground Location Center (ID,MT,ND,OR,WA) 300 295 290 285 280 275 270 265 O O N o 'q- O6 + 00 O N n II II H (N W 12 13 14 15 16 17 18 ROAD A 19 20 21 22 qFF gHFFT WA—nl 04 O It 00 It CO It 1`0r- N � I� � n O 00 '.4- 0000 'q- 00 00 0000 N 0000 No; 00 ^ n 00 ^ N 00 � I' O r- � N N N N N N N N N N N N N N N N N N N PROPOSED GRADE PROPOSED SEWER CENTER OF CUL-DE-SAC STA 71 +87.41 , ALLEY E = STA. 6+26.68, ROAD A ELEV=275.85 O O N N + 0) � N n 00 N M o' EX. GROUND 3' MIN II + + � � II COVER r- � 00 II II Oo N +Ui �_ Q �� N as NLQ Ld II II cn w \ .5 % a a 71 +00 CERTIFICATION FOR AS—BUILTS ONLY. �.•S. A. , SEE APPROVED PLANS BY ESM CONSULTING ENGINEERS :.�� ° ti '• DATED JANUARY 30, 2018, JOB #1938-001 —01 6. 0 FIRST SUBMITTAL �P 1 SECOND SUBMITTAL 2 THIRD SUBMITTAL 2 715R��•. Q7 AS -BUILT �FSS/ONAL 6-S-1--70I15 NO. REVISION PROPOSED STORM 72+00 ESM 08/30/17 SURVEYED: ESM 11/15/17 DESIGNED: ESM 01/03/18 PDG DRAWN: CHECKED: BY I DATE I APPR I APPROVED SCALE: 1 "=20' ONE INCH AT FULL SCALE IF NOT ONE INCH SCALE ACCORDINGLY 300 295 290 285 275 270 265 VERTICAL: NAVD 1988 HORIZONTAL: NAD 1983/1991 DATU M • CITY OF qq RENTON Planning/Building/Public Works Dept. n SCALE: 1 "=20' HORIZ. 1 "=5' VERT. CONTOUR INTERVAL = 2' 20 10 0 20 40 1. A 6" THICK ETHAFOAM PAD TO BE PLACED IN BETWEEN PIPES WHERE MINIMUM PIPE SEPARATION OF 18" CANNOT BE ACHIEVED. 2. AN INDIVIDUAL 1" PRESSURE REDUCING VALVE (PRV) IS REQUIRED DOWNSTREAM OF EACH DOMESTIC WATER METER BECAUSE THE STATIC WATER PRESSURE IS OVER 80 PSI PER COR STANDARD PLAN 340.5. 3. DCVA REQUIRED BEHIND EACH METER IF BUILDINGS ARE 3-STORY (TYPICAL FOR ALL METERS.) IN COMPLIANCE WITH CITY OF RENTON STANDARDS EARLINGTON TOWNHOMES WATER PLAN & PROFILE UTILITY PERMIT # 01/23/18 FIELDBOOK: PAGE: DRAWING NO: WA-04 SHEET: OF: 43 55 0 u� H Q J u� H a_ W— 39 7106