Loading...
HomeMy WebLinkAboutR-430704DEVELOPMENT ENGINEERING TALBOT HILL ELEMENTARY SCHOOL A PORTION OF THE NE 1/4 OF THE NE 1/4 OF SEC. 30, TWNm 23 N., RGEm 05 E. W.M. CITY OF RENTON, KING COUNTY, WASHINGTON. GRASS SEED, SEE SPECIFICATIONS ROOT ZONE SAND MIX, SEE SPECIFICATIONS BASE SAND MIX, SEE c) SPECIFICATIONS i TRENCH LIMITS z z v 0 PEA GRAVEL BACKFILL Zi °moo "° ° FIRM TRENCH SIDES WITH NO \� oo o o \\\\\/\\\ LOOSE MATERIAL ON BOTTOM R /\ OF TRENCH GEOTEXTILE FABRIC 4" PVC UNDERDRAIN PIPE PEA GRAVEL UNDER PIPE SUBGRADE 4" PERFORATED UNDERDRAIN NOT TO SCALE 0 Know what's below. call before you dig. FINISH GRADE 30% VOID RATIO OF ® %.. ° 4p� ° Sa PEA GRAVEL •4 0 °° o sn4 0 ., o a4 0 °, o u4 0 °, o 0 8 N-12 PERFORATED0 0, v00°°�0 COLLECTOR DRAIN AS PER PLAN ,.�, icy °n .. Lp= g, � •b�B��°a EX�=, e COO• .. UU'"' ° �. i7' c�j• &`°°°s®°° GEOTEXTILE�0 °� p�0 0 °� FABRIC °, °, T::.:�s 1::.,8a °q-�':.,&� 8°':°.8$ % 24" M I N 8" COLLECTOR DRAIN NOT TO SCALE 75 STORMTECH MC-7200 CHAMBERS 200.32 MAXIMUM ALLOWABLE GRADE (TOP OF PAVEMENT/UNPAVED) 14 STORMTECH MC-7200 END CAPS 195.82 MINIMUM ALLOWABLE GRADE (UNPAVED WITH TRAFFIC) 12 STONE ABOVE (in) 195.32 MINIMUM ALLOWABLE GRADE (UNPAVED NO TRAFFIC) 12 STONE BELOW (in) 195.32 MINIMUM ALLOWABLE GRADE (BASE OF FLEXIBLE PAVEMENT) 40 % STONE VOID 195.32 MINIMUM ALLOWABLE GRADE (TOP OF RIGID PAVEMENT) 5,461 SYSTEM AREA (ftz) 194.32 TOP OF STONE 328 SYSTEM PERIMETER (ft) 193.32 TOP OF MC-7200 CHAMBER 20,665 MINIMUM INSTALLED STORAGE (C9 191.29 12" TOP MANIFOLD INVERT 188.51 24" ISOLATOR ROW PLUS CONNECTION INVERT 188.45 12" BOTTOM MANIFOLD INVERT 188.32 BOTTOM OF MC-7200 CHAMBER 187.32 UNDERDRAIN INVERT 187.32 BOTTOM OF STONE ISOLATOR ROW PLUS (SEE DETAIL) PLACE MINIMUM 17.50' OF ADSPLUS125 WOVEN GEOTEXTILE OVER BEDDING STONE AND UNDERNEATH CHAMBER FEET FOR SCOUR PROTECTION AT ALL CHAMBER INLET ROWS BED LIMITS PART TYPE PREFABRICATED END CAP PREFABRICATED END CAP PREFABRICATED END CAP FLAMP MANIFOLD MANIFOLD NYLOPLAST (INLET W/ ISO PLUS ROW) CATCH BASIN (5/C3) NYLOF (OUTLET) UNDERDRAIN INSPECTION PORT I�1 116.86 z Q J 0- Ir- z N W FINISH GRADE PEA GRAVEL BACKFILL UNDERDRAIN PIPE ALT. CONNECTION WHERE INVERT ELEVATIONS ALLOWS. 90 DEG. ELL. W/ 90 DEG. REDUCING SNAP TEE. PERFORATED COLLECTOR DRAIN PIPE, ELEVATION PER FIELD DRAINAGE PLAN 90 DEG. REDUCING SNAP TEE OR 45 DEG. SNAP Y AND REDUCING COUPLING AS REQUIRED (NO 5'-0" � SADDLE TEES). 2" DEPTH MIN. PEA GRAVEL BENEATH PIPE (TYP) GEOTEXTILE FABRIC COLLECTOR DRAIN CONNECTION NOT TO SCALE 'INVERT ABOVE BASE OF CHAMBER w DESCRIPTION INVERT'MAX FLOW A OU A 12" BOTTOM PARTIAL CUT END CAP, PART#: MC72001EPP12B / TYP OF ALL 12" BOTTOM 1.55" CONNECTIONS z W < C)D3 2 o w o B 12" TOP PARTIAL CUT END CAP, PART#: MC72001EPP12T / TYP OF ALL 12" TOP CONNECTIONS 35.69" 24" BOTTOM PARTIAL CUT END CAP, PART#: MC72001EPP24B / TYP OF ALL 24" BOTTOM C CONNECTIONS AND ISOLATOR PLUS ROWS 2 26" J =) LLI J Q Q LLI J 2 z z ?: 0 U _ U o o D INSTALL FLAMP ON 24" ACCESS PIPE / PART#: MCFLAMP E 12" x 12" BOTTOM MANIFOLD, ADS N-12 1.55" F 12" x 12" TOP MANIFOLD, ADS N-12 35.69" G 30" DIAMETER (24.00" SUMP MIN) 7.5 CFS IN = (U o 11 It ce v o rn :� w zz_ LASTH 30" DIAMETER DESIGN BY ENGINEER PER PLAN ( ) 6.0 CFS OUT O m J Q N N Ln O co � w o W I 6" ADS N-12 DUAL WALL PERFORATED HDPE UNDERDRAIN J 4" SEE DETAIL H U w Q o a u>, � a I51.61' w w n z O ww 2 -H F- z w O_ LU �' W ti K w a >Z I �Q zZ Z W O I C) �w U � ww I � a w w� W ¢ I In OU M O ¢ I w w ¢ z I 2E z W w C) U Z. I L) ❑ w w � w� Fo rn a I Of ® o w �U LLO O >� E > O ¢ I y - oa � o rn �~ U L N O) w a w pE 000 ¢ Lq I 000 y 0 o o ow o. N a = zW > LO NO Owl J m Q N W O I6.59' <_� z� LU O r O w J �pC%7 �¢_� oz aW O J O O o z w o V2 ao ww a� zN NOTES m • MANIFOLD SIZE TO BE DETERMINED BY SITE DESIGN ENGINEER. SEE TECHNICAL NOTE 6.32 FOR MANIFOLD SIZING GUIDANCE. LL • DUE TO THE ADAPTATION OF THIS CHAMBER SYSTEM TO SPECIFIC SITE AND DESIGN CONSTRAINTS, IT MAY BE NECESSARY TO CUT AND COUPLE ADDITIONAL PIPE 10 � z r TO STANDARD MANIFOLD COMPONENTS IN THE FIELD. N • THIS CHAMBER SYSTEM WAS DESIGNED WITHOUT SITE -SPECIFIC INFORMATION ON SOIL CONDITIONS OR BEARING CAPACITY. THE SITE DESIGN ENGINEER IS o 0 RESPONSIBLE FOR DETERMINING THE SUITABILITY OF THE SOIL AND PROVIDING THE BEARING CAPACITY OF THE INSITU SOILS. THE BASE STONE DEPTH MAY BE yLL = W INCREASED OR DECREASED ONCE THIS INFORMATION IS PROVIDED. • THE SITE DESIGN ENGINEER MUST REVIEW ELEVATIONS AND IF NECESSARY ADJUST GRADING TO ENSURE THE CHAMBER COVER REQUIREMENTS ARE MET. SHEET 2OF6 ADS STORMTECH MC-7200 STORMWATER DRAINAGE DETENTION FACILITY DETAILS NOT TO SCALE .r W-V FLAT FACE GOTHIC o a I- r DIA ---I o>do � a 0 $TOM 0 4- 0000 CIO HY1r8' DA 76772' DIA I2j M'-,6 S$ SOCI(ET WAD CAP 15' OIA 11) OPEN PICKHOLE 1' SCREW (ALLENHEAD) WAMSHAS ON A B' CIA BOLT CIRCLE COVER SECTION CAST {RON FRAME AND PAVED AREA ITYP.} COVER SEE NOTE 3 t�° 1p• EXTEND DESIGN NDIN SER 2' ABOVE CESiGH PGNDING ELEVATION OR PER PLAN FERNCO GASKETED 011IK CAP Ili 54MILRR DESIGN PONDtNG �!: ELEVATION 4. 57TiElUAgED COBBLES CLASS �• - PER W5DO7 �03.171$y ASPHALTS' 5EE NOTE 1 CLFJWOLII RISER. SEE NOTE +•COMPACTED SAND OR GRAVEL BACKFILL FOR DRAINS PER WSDOT 8-03.12f41 -1-1I, T CLEANOUT RISER. rT1 SOIL TK3HT 45' BEND SEE NOTE 7 l AT SOIL TIGHT GHT I COUPLER 1T UHDERDRAIN, FDOTINC IT DRAIN G9LLEGTdi, OR ROOF DRAIN COLLECTOR PIPE. SEE NOTE T - CLEANOUT RISER LOCATED WITHIN BIORE'TENTION PONDING AREA •"-.- , liiliiill TOOVERFLOW STRUCTURE OR STORM MAIN MECHANICAL PLUG OR CONTINUED CONNECTION TYPICAL CLEANOUT CONFIGURAT1011 NOTES; 1. DIAMETER TO BE &INCHES MINr"UM PRIVATE. 8-INCHES MINIMUM PUBLIC. UNDERORAIN PIPE PER STD PLAN 262.1D 2. CLEANOUT RISER SHALL BE SAME MATERIAL AS CONNECTED UNDERDRAIN. FOOTING DRAIN COLLECTOR DR ROOF BRAIN COLLECTOR PIPE 3 FRAME A20 COVER SHALL BE EA PRODUCTS 3f 7U11PT AND M75APT OR APPROVED EQUAL COVER TA BE LOCKING WITH ALLEN MEAD BOLT, MARKED "5TORM" OR 'iIRAIN' A. FOR CLEANOUTS FULLY OR PARTLALLY WITHIN UNPAVED AREAS OUTSIDE OF BIDRETENTION FUNDING AREA, POUR S' THICK 9'I17 SQUARE CONCRETE COLLAR AROUND FRAME. CONCRETE COLLAR SHALL HAVE A MINIMUM COMPRESSIVE STRENGTH OF 3.OW PSI. GENERAL NOTES: 1 . CLEANOUTS FOR UNDERORAIN. FDOTING DRAIN COLLECTOR, AND ROOF DRAIN COLLECTOR PIPES SMALL BE INSTALLED AT A MINIMUM OF EVERY 100 FEET. AT EVERY W DEGREE OR SECOND 45 DEGREE BEND, AT THE END OF EVERY COLLECTOR PIPE AND AT EACH END OF AN UNDERDRMN PIPE NOT CONNECTED TO AN OVERFLOW STRUCTURE CLEANOUT5 SHALL SE INSTALLED TO ALLOW FOR MAINTENANCE ACCESS TO ALL PEES_ 2- ALL FITTINGS SHALL BE SOIL TIGHT. 3. CLEANOUT RISER SHALL BE LOCATED OUTSIDE OF MORETENTION PONOING WHERE POSSIBLE 4. CLEANOUTS SHALL NOT BE LOCATED WITHIN THE STREET TRAVEL LANI=, UNLESS OTHERWISE APPROVED BY THE CITY. UNLf55 OTHERWISE NCTE°, DRAWING IS NOT TO SCALE { NTS I STD. PLAN - 226,00 PUBLIC WORKS °6' .� STORM SYSTEM CLEANOUT s/13/20 ❑EPARTMENT artin Pastucha V4337 DATE COLLECTOR DRAIN CLEAN OUT NOT TO SCALE 7 MIN. CLEARANCE TO ANY PORTION OF FLOW RESTRICTOR TEE INCLUDING ELBOWS , REMOVABLE f►� jl I O FLANGE COUPLING OR FLANGE 3'HAIIN. A ELBOW RESTRICTIOIK SEEDETAILANDNDTE 10 j J ANGLE AS NECESSARY, / SEE NOTE B MIN. ' MIN, ^-� S" MAX. PLATE WELDED TO ELBOW WITH PLAN VIEW IE4I; ICE AS SPECIFIED, SEE NOTE 3 ELBOW RESTRICTOR DETAIL ADDITIONAL LADDER RUNGS (IN SET5I TO ALLOW ACCESS TO TANKS OR VAULT$ WHEN CATCH I5 HUED WITH WATER FL EVATI ON PER PLANS 72" MIN UNDER r FRAME d SOLID COVER MARKED 'DRlUN" WITH PAVEMENT 1 LOCKING BOLTS PER STD PLANS 2N.40 AND 204.50 !! RIM ELEV. = IW.61 ERTICAL BAR GRATE FOR SECONDARY INLET 6 MINOP -OF RISER 1 DESIGN WATER ELBOW RESTRICTOR,URFACE ELEV- = 195.40 SEE DETAIL AND NOTE IDRANDHOLDS. STEPS. OR LADDER PIPE SUPPORTS, SEE NO 1 5 x rD 5EE NOTE 13 ITYP.N7x OUTLET PIPE. SINLET PIPE 12, PVC amn IE 188.44 NOTES I A 6INVERT ANDSHEAR GATE WITH CONTROL ROD FOR ELEVATION PER PLANSC. (ROD T At,WITH REQUCOVE RED FORCILEVERTICALA L FOR VERTICAL ALIGNMENT WITH COVER] NT 72' SECTION OF PIPE ATTACHED BY 1 PER S7p PLAN 237.3E GA.SKETED SAID TO ALLOW REMOVAL c� 2' 12 MIN WELDED ROLA ORIFICE 61AASESTRECTSPECIFIEDRPTE. 5EE NWITHOTE 10 ELEV = 186.40 ORIFICE DIA = 0.559• SECTION A NOTES: 1 USE A MINIMUM OF A 64" DABAMFI TYPE 2 CATCH BASIN. 2. OUTLET CAPACITY: 100•YEAR DEVELOPED PEAK FLOW. 3. METAL PARTS PREFERRED TO BE STAINLESS STEEL, ALUMIN2ED STEEL, OR ALUMINUM. ALL OTHER STEEL PARTS MUST BE GALVANIZE D VJHTH TREATMENTS 1, 2 OR 5. i FRAME AND LADDER OR STEA$ OFFSET SD: A CLEANOUT GATE 15 VISIBLE FROM TOP. B CLIMB -DOWN SPACE IS CLEAR Of RISER AND CLEANOUT GATE. C FRAME IS CLEAR OF CURB. S. IF METAL OUTLET PIPE CONNECTS TO CEMENT CONCRETE PIPE: OUTLET PIPE TO HAVE SMOOTH O.D. EQUAL TO CONCRETE PIPE 10. LESS 114'. 6. PROVIDE AT LEAST ONE 3' X .080 GAGE SUPPORT BRACKET ANCHORED TO CONCRETE WALL IMA%IMUM T-O' VERTICAL SPACINGI 1. LOCATE ELBOW RESTRICTORISi AS NECESSARY TO PROVIDE MINIMUM CLEARANCE AS SH IC WN. B. LOCATE ADDITIONAL LADDER RUNGS 04 STRUCTURES USED ASACCESS TD TANKS AND VAULTS TO ALLOW ACCESS VMFN CATCH BASIN 19 KILLED WITH WATER 9. WHEN CONNECTING TD A NEW PIPE, U SE A FLEX{BLE CONRECTOR IKOR-N-5EAL BOOT WITH C(5RRUGATED PIPE A°APTER OR APPROVED EULIALI. WHEN CONNECTING TO AN EXISTING PIPE, USE A FABRICATED SAND COLLAR OF THE SAME MATERIAL AS THE CONNECTING PIPE. 10. IF TEE SECTION IS USED ONLY FOR SPILL CONTROL T4[EN ELBOW RE STRI CTORS AND RE STRICTOR PLATES WITH ORIFICES ARE NOT REM IRFD. UNLESS OTHER WISE NOTES, DRAWING IS NOT TO SCALE {FMI STD. PLAN - 237.00 . �� PUBLIC WORKS FLOW CONTROL STRUCTURE - 6y UAL DEPARTMENT UR RESTRIC€OR TEE Martin Pastucha 8/i3�70 JI Ir 786WOD DATE CONTROL STRUCTURE NOT TO SCALE 0 CD LO N O 0 N 14, � J C C R=430704 TACOMA • SEATTLE • SPOKANE • TRI-CITIES 2215 North 30th Street, Suite 300 Tacoma, WA 98403 253.383.2422 TEL 253.383.2572 FAX www.ahbl.com WEB Project Title: TALBOT HILL ELEMENTARY SCHOOL Client: RENTON SCHOOL DISTRICT ANDREW HOLLENBACK 300 SOUTHWEST 7TH STREET RENTON, WA 98057 Project No. 2230870.10 Issue Set & Date: PERMIT SET JULY 9, 2024 7/9/2024 NOTICE ALTERATION OF THIS DOME NT SHALL INVALDATE THE PROFESSIONAL SEAL AND SIGNATURE PUBLICATION OF THIS DOCUMENT DOES NOT DEROGATE FROM RESERVED OII EiSIf MRS N IT. THIS DOCUMENT IS FOR USE ONLY FOR THE PROM DARED N THE TITLE BLOC( AND IS NOT TO BE USED FOR REPAIR, REMODEL OR ADDITION TO THAT PROAM OR FOR ANY OTHER PROJ7. A Revisions: Sheet Title: STORMWATER DRAINAGE DETAILS Designed by: Drawn by- Checked by: JAD JAD DCN Sheet No- 04 of 05 Sheets