Loading...
HomeMy WebLinkAboutzR-4307setti O M CD H DEVELOPMENT ENGINEERING SAMorman 08/02/2024 Surface Water Enginering JFarah 08/15/2024 0 TALBOT HILL ELEMENTARY SCHOOL to A PORTION OF THE NE 1/4 OF THE NE 1/4 OF SEC. 30, TWNm 23 N., o RGEm 05 E. W.M. CITY OF RENTON, KING COUNTY, WASHINGTON. � N U S 23RD STREET AZ 90_01_25.32" wepe[nry 0[ / D — u CO �ILi 0 / \ \\ • i O / TALBOT HILL / ELEMENTARY SCHOOL CO �1 I / �a �� AHBL #102 NAIL AND WASHERN: 170127.2236 / E:1299508.3349 �-s AHBL #103 ELEV: 203.33 N L AND WASHER IM _ N:170139.6149 E:1299844.2959 Ico ELEV: 206.16 N �\ o Q ST / T L0 N / T9a / I Z 71'43'19.32" Know what's below. Call before you dig. PARCEL NUMBER 3023059073 SITE ADDRESS 2300 TALBOT ROAD S, RENTON, WA 98055 VERTICAL DATUM NAVD 1988 VERTICAL DATUM ON ORTHOMETRICALLY CORRECTED GPS OBSERVATIONS USING WSRN AND GEOID 2012A. VERIFIED CITY OF RENTON 230 (CASE MONUMENT AT S 23RD ST AND WILLIAMS AVE CUL DE SAC) ELEV: 230.75 BASIS OF BEARING NAD 1983 WASHINGTON STATE PLANE NORTH PROJECTION, BASED ON GPS OBSERVATIONS USING WSRN AND GEOID 2012A. UNITS OF MEASUREMENT ARE US SURVEY FEET. VERIFIED CITY OF RENTON 230 (CASE MONUMENT AT S 23RD ST AND WILLIAMS AVE CUL DE SAC) LEGAL DESCRIPTION A PORTION OF THE NE 1/4 OF THE NE 1/4 OF SEC. 30, TWIN. 23 N., RGE. 05 E. W.M. CITY OF RENTON, KING COUNTY, WASHINGTON FILL SPECIFICATION FILL MATERIAL SHALL NOT CONTAIN PETROLEUM PRODUCTS, OR SUBSTANCES WHICH ARE HAZARDOUS, DANGEROUS, TOXIC, OR WHICH OTHERWISE VIOLATE ANY STATE, FEDERAL, OR LOCAL LAW, ORDINANCE, CODE, REGULATION, RULE, ORDER, OR STANDARD. AS -BUILT NOTE CONTRACTOR SHALL FURNISH AS -BUILT RIM ELEVATIONS, PIPE INVERT ELEVATIONS, AND STRUCTURE LOCATIONS (COORDINATES) TO THE NEAREST 0.01 FOOT FOR ALL STORM DRAINAGE AND UTILITY STRUCTURES, AND AS -BUILT SLOPE MEASUREMENTS TO THE NEAREST 0.01 % FOR ALL CURB RAMP AND LANDING PANEL JOINTS. CONTRACTOR SHALL ENGAGE WITH A PROFESSIONAL LAND SURVEYOR LICENSED IN THE STATE OF WASHINGTON TO FURNISH AS -BUILT INFORMATION. AUTOCAD FILE AN AUTOCAD DRAWING FILE IS AVAILABLE TO ASSIST WITH SITE LAYOUT. PLEASE NOTE THAT ELECTRONIC FILES ARE PROVIDED FOR CONTRACTOR'S CONVENIENCE AND SHALL NOT REPLACE NOR BE USED TO SUBSTITUTE THE CONTRACT DOCUMENTS. THE CONTRACTOR IS RESPONSIBLE FOR PROJECT LAYOUT ACCORDING TO CONTRACT DOCUMENTS AND COST FOR ELECTRONIC AUTOCAD FILES. PHONE: (253) 383-2422 FAX: (253) 383-2572 CONTACT: JAMES A. DALEY TOPOGRAPHIC NOTE THE EXISTING CULTURAL AND TOPOGRAPHIC DATA SHOWN ON THESE DRAWINGS HAS BEEN PREPARED, IN PART, BASED UPON INFORMATION FURNISHED BY OTHERS. WHILE THIS INFORMATION IS BELIEVED TO BE RELIABLE, AHBL CANNOT ENSURE ACCURACY AND THUS IS NOT RESPONSIBLE FOR THE ACCURACY OF THAT INFORMATION OR FOR ANY ERRORS OR OMISSIONS WHICH MAY HAVE BEEN INCORPORATED INTO THESE DRAWINGS AS A RESULT. TRENCH NOTE IF WORKERS ENTER ANY TRENCH OR OTHER EXCAVATION FOUR OR MORE FEET IN DEPTH THAT DOES NOT MEET THE OPEN PIT REQUIREMENTS OF WSDOT SECTION 2-09.3(3)B, IT SHALL BE SHORED AND CRIBBED. THE CONTRACTOR ALONE SHALL BE RESPONSIBLE FOR WORKER SAFETY AND AHBL ASSUMES NO RESPONSIBILITY. ALL TRENCH SAFETY SYSTEMS SHALL MEET THE REQUIREMENTS OF THE WASHINGTON INDUSTRIAL SAFETY AND HEALTH ACT, CHAPTER 49.17 RCW. UTILITY NOTE THE LOCATIONS OF EXISTING UNDERGROUND UTILITIES ARE APPROXIMATE ONLY AND HAVE NOT BEEN INDEPENDENTLY VERIFIED BY THE OWNER OR ITS REPRESENTATIVE. THE CONTRACTOR SHALL DETERMINE THE EXACT LOCATION OF ALL EXISTING UTILITIES BEFORE COMMENCING WORK AND AGREES TO BE FULLY RESPONSIBLE FOR ANY AND ALL DAMAGES THAT INCUR DUE TO THE CONTRACTOR'S FAILURE TO LOCATE EXACTLY AND PRESERVE ANY AND ALL UNDERGROUND UTILITIES. AHBL ASSUMES NO LIABILITY FOR THE LOCATION OF UNDERGROUND UTILITIES. VICINITY MAP NOT TO SCALE OWNER/APPLICANT RENTON SCHOOL DISTRICT 300 SOUTHWEST 7TH STREET RENTON, WA 98057 PHONE: 425-204-4437 CONTACT: ANDREW HOLLENBACK EMAIL: ANDREW. HOLLENBACK@RENTONSCHOOLS.US ARCHITECT HUTTEBALL + OREMUS ARCHITECTURE 4010 LAKE WASHINGTON BOULEVARD NE, SUITE 320 KIRKLAND, WA 98033 PHONE: 425-828-8948 CONTACT: KEVIN OREMUS EMAIL: KOREMUS@HOARCH.COM N 8 CIVIL ENGINEER AHBL INC. 2215 NORTH 30TH STREET, SUITE 300 TACOMA, WA 98403 PHONE: 253-383-2422 CONTACT: DAVID NASON EMAIL: DNASON@AHBL.COM SURVEYOR AHBL INC. 2215 NORTH 30TH STREET, SUITE 300 TACOMA, WA 98403 PHONE: 253-383-2422 CONTACT: DAVE FOLLANSBEE EMAIL: DFOLLANSBEE@AHBL.COM GRAPHIC SCALE 0 25 50 100 1" = 50 FEET SHEET INDEX Sheet No. Sheet Title CO COVER SHEET C1 PLAY FIELD STORMWATER DRAINAGE PLAN C2 STORMWATER DRAINAGE NOTES & DETAILS C3 STORMWATER DRAINAGE DETAILS C4 STORMWATER DRAINAGE DETAILS R=430701 TACOMA • SEATTLE • SPOKANE • TRI-CITIES 2215 North 30th Street, Suite 300 Tacoma, WA 98403 253.383.2422 TEL 253.383.2572 FAX www.ahbl.com WEB Project Title: TALBOT HILL ELEMENTARY SCHOOL Client: RENTON SCHOOL DISTRICT ANDREW HOLLENBACK 300 SOUTHWEST 7TH STREET RENTON, WA 98057 Project No. 2230870.10 Issue Set & Date: A A PERMIT SET JULY 9, 2024 7/9/2024 NOTICE ALTERATION OF THIS DOM ENT SHALL IWALDATE THE PROFESSIONAL SEAL AND SIGNATURE PUBLICATION OF THIS DODAIENT DOES NOT DEROGATE FROM RESERVED OWNERSW RIMS N IT. THIS DOCUMENT IS FOR USE ONLY FOR THE PROD= IDENTIFIED N THE TIT E BLOCK AND IS NOT TO BE USED FOR REPAIR, REMODEL OR ADDITION TO THAT PROM OR FOR ANY OTHER PROJECT. A Revisions: Sheet Title: COVER SHEET Designed by: Drawn by- Checked by: JAD JAD DCN Sheet No. 01 of 05 Sheets ti O M W H DEVELOPMENT ENGINEERING O SAMorman 08/02/2024 kimoto LO A PORTION OF THE NE 1/4 OF THE NE 1/4 OF SEC. 30, TWNm 23 N. N 0 RGEm 05 E. W.M. CITY OF RENTON, KING COUNTY, WASHINGTON. o qe NSTCB 1376 CONNECT TO EXISTING \ \\ \ / RIM-196.96/�0 STORMWATER MANHOLE \ \ I / 8" PVC SE IP TYP \ 0 IE:183.50 \ \ I / IE=194.93 STMH 1812 RIM=193.17 I I I I I I / 8" PVC SW- 12" CPP S IE=186.57 I \\ I I I I I \ / IE=194.59 18" CPP W IE=184.17 _ _ 36" CMP NW IE=183.50 I \ \ I I I I I \ \ / \ I PV_ PER Aso LADDER E I I I ` 997 2 T \ STMH 1814 RIM=189.51 / I I I ) % /� / , //\ 18" CPP E IE=185.29 / 4" INSPECTION PORT__` BEEHIVE GRATE \ // I \ A / LADDER S \// / / / O/ I TCB 1377 IIIM-200. \ O Z / 8"\PVC SE IE=195.6 STCB 1=200.22 \ STCB 1160 RIM=205.65 ISOLATOR 1 �� NW IE\195. 8" PV-196.16 - \ �� \ \ / I I ROW C�4 \ C N=196.15 10" CPP N IE=201.90 / � � Q 6" PVC E IE=201.65 I / 41 LF 12" PVC SDR-35 @ 12.0% / / / / / 8" PVC SE IE=201.05 / ` �_�_ //o \ 10" CPP NW IE=200.75 C2 C2 3 6 REPLACE AND REPAIR FENCE �� RIM=201.92 CATCH BASIN TYPE 2, 60" / / / j ND=197.92 ♦ \ , 5 CONTROLSTRUCTURE1 / � / I ♦ � � \ � \� � / C3 RIM: 197.61 I (/ / / I / \/ \ \ LOCATIO STCB IE: 188.40 8" (E,W) / / / �\D \ THAT W RE VED 5 LF 12" PVC SDR-35 @ 0.0% / } / / o , / I / AND LI ABAND ED IN C2 C2 % � o, �� , oN / , ♦ � \ \PEACE 97 C 2 C4 NYLOPLAST CATCH BASIN / / / �/ ���♦ / / / \ / \ \ \ - - _ _ STCB 11: IE: 188.40 / / �/ o\°/ ♦ / / / \ / / 4" UNDERDRAIN k �P/ / / ♦ / ♦ \ / / 2 \ 1 IM 6 PVC 8N 6 1 2 6" ADS N-12 PERFORATED / / / ��� ♦ @/ �� , I / /� �� �4� \ PVC CAP (TYP) I IE=204.z C3 C4 C4 UNDERDRAIN / I �Q ♦ �/ p� I j 1 , \/ 1 � STORMWATER DETENTION FACILITY / %♦ I �� ♦ �/ �� ♦ / % I / I / / / I / \x \\ 75 STORMTECH MC-7200 CHAMBERS / ♦ I Oj R. o�j ♦ / ♦ / / ♦ ♦ ♦ I / ,� x, �x 14 STORMTECH MC-7200 END CAPS / I �`5 / I J�♦ O�j �y �� ♦ / o I / ♦ j I / / ♦ , \ - x� / / / o I Q- �/ �` I FACILITY DIMENSIONS: 116.86' x 47.27' x 7 / I / O�� P / o�� I ♦ '/I I / I % \�� I TOP STONE/ELEV: 194.32 6 1 TOP CHAMBER/ELEV: 193.32 / 1g I / .^ J ♦ O ♦ / �, I / ♦ / ♦ ♦ / / , ♦ / ♦ i3� - C3 �C4 BOT CHAMBER/ELEV: 188.32 \ I ♦ v / p� / P / o\°/ °��/ , CCDI / I� , ,I I / ♦ / / BOT STONE/ELEV: 187.32 / \ \ \ ♦ / J� / / N./ o N ♦ / / / ♦ / ♦ / \ / I BOT/AREA: 5,459 SIF ♦ / / Q ��' / \ / ♦ / M I / I / / / / x N,R. STCB 1375 RIM=195.34 TYP SF \ \ ♦ /\ ♦ �� / J ♦ Off♦ �Q / �P ♦ o / / ♦ ♦ / V / / / / , / 12" CPP N IE=190.29 6 1 MANIFOLD \ _ \ \ ♦ \ / ♦ ♦ ��♦ �♦ QO/♦ �/♦ / ♦ / I ♦ / I ♦ % k 8" PVC NE IE=192.84 C3 C4 \ / / / / �p ♦ / Off/ �♦ °\° / / / ♦ / I / / 4" PVC NE IE=190.74 � / / / �♦ J ♦ `L / � P/ ``�/ ♦ / I / / / / ♦ / I ♦ @J / �` ^ / ♦ o / 8" PVC SE IE=192.84 NYLOPLAST INLET WITH % , / / 6 1 2 ISO PLUS ROW �� j I ��� J♦ // o� \��% °��% / ♦ �. ♦ j x I / / / I IE:191.70 / \ I , ♦ cc � , � / ♦ / \ �'` / Jam, � / �, �' o\° , ♦ / / 1 / / / / / ' 19O/ �Oj �P / o/ / / / ♦ / , / / / 11 LF 8" N-12 @ 10.0% TYP IP \ \ O ♦ \ / / �\ ♦ u , p�/ ♦ QO/ (�J� �\�/ I ♦ / / / / 2 PERFORATEDJ�/ COLLECTOR DRAIN %\ I \ / / / ♦ o / ( ♦ ♦ �P ♦ ^o ♦ / / / \ / ♦ / / / C3 \ / / / / `b/ JI O ♦ / � / / SDCO #2 / �\ \\ I / / ♦ / % I ^/, �Q- ♦ @J, ° / ♦ / k \ / / / ♦ / �♦ �♦ ^, ♦ / \ 4 RIM: 198.01 ( \ j j / / ��♦ I / / J ♦ Q ♦ �\ ♦ ♦ ♦ ♦ / ' � N C3 IE: 192.80 \X 1 \ / , / , / I / �°'/ / Qp/ @J ♦ I / ♦ ♦ j \ ` l l / x�x \ \ ♦ \ / ♦ / / / ♦ �v / �Q/♦ Q ♦ o\/ ♦ / / / / / &, JIk I / �Pj ^ / ♦ (oIV / / / / / / ♦ I / p� /LP ♦ o, STCB 573 RIM=197.25 ♦ , / ♦ ♦ , p / Q- ♦ �/ ♦ / / / / GRAPHIC SCALE 0 10 20 40 1" = 20 FEET LEGEND IP ® INLET PROTECTION 4 C2 SF SILT FENCE 5 C2 O CATCH BASIN TYPE 2, 60" CONTROLSTRUCTURE • STORM DRAINAGE CLEANOUT D STORM DRAINAGE PIPE - - - - - - - - - - - - - PERFORATED UNDERDRAIN n PERFORATED UNDERDRAIN CAP DETENTION TRENCH FACILITY 0 0 Know what's below. Call before you dig. GRASS SEE, SEE SPECIFICATIONS 3 Y4" ROOT ZONE SAND MIX, SEE SPECIFICATIONS 8" BASE SAND MIX, SEE SPEFICICATIONS FINISH COMMON GRADE BORROW FILL 8" PVC SE IE=194.65 / / / / , / u , Q�/ P / p\o / / / / N / / 8" PVC NW IE=194.63 ♦ / / , / / ,moo / Jam/ O� / �/ / / / / / / `�'♦ D / Q' / STCB 574 RIM=199.20 8" PVC SE IE=196.45 8" PVC NW IE=196.43 315 LF 8" N-12 @ 2.8% 2 PERFORATED j /� I % ��� J�Q/♦ �!/ �xz X�� COLLECTOR DRAIN , / I / I / / \^/ / -X74- STCB 577 RIM=204.70 8" PVC SW IE=202.77 L TOP OF DETENTION TRENCH BEDDING STONE, ELEV: 194.32 TYPICAL DETENTION TRENCH & FIELD RESTORATION SECTION SCALE: 1" = 1' GRASS SEE, / \ / / / ♦ / , �` SEE SPECIFICATIONS ♦ / , ♦ / / IP TYP 3 Y4" ROOT ZONE SAND MIX, SEE SPECIFICATIONS STCB 575 RIM=201.28 ♦ / / 7`5��1- / I / }/ 8" BASE SAND MIX, 8" PVC SE IE=198.60 SEE SPEFICICATIONS FINISH 8" PVC NW IE=198.58 \ \ \ \\ / / / �\ GRADE \ I / / 4" PVC SDR-35 PERFORATED 1 SUBGRADE ♦ \I j UNDERDRAIN (TYP) C3 TYPICAL FIELD RESTORATION SECTION SCALE: 1" = 1' 3 UNDERDRAIN / COLLECTOR C3 DRAIN CONNECTION (TYP) 4 SDCO #1 C3 RIM:203.26 IE:201.62 1} STCB 576 RIM=203.25 / } 8" PVC NE IE=200.63 8" PVC NW IE=200.60 R=430702 TACOMA - SEATTLE - SPOKANE - TRI-CITIES 2215 North 30th Street, Suite 300 Tacoma, WA 98403 253.383.2422 TEL 253.383.2572 FAX www.ahbl.com WEB Project Title: TALBOT HILL ELEMENTARY SCHOOL Client: RENTON SCHOOL DISTRICT ANDREW HOLLENBACK 300 SOUTHWEST 7TH STREET RENTON, WA 98057 Project No. 2230870.10 Issue Set & Date: PERMIT SET JULY 9, 2024 w-w-v " 7/9/2024 NOTICE ALTERATION OF THIS DOCUIENT SHALL IWALDATE THE PROFESSIONAL SEAL AND SIGNATURE PUBLICATION OF THIS DOCUIENT DOES NOT DEROGATE FROM RESERVED OXIFRSW RIMS N IT. THIS DOCUMENT IS FOR USE ONLY FOR THE PROJECT IDENTIFIED N THE TIT E BLOCI AND IS NOT TO BE USED FOR REPAIR, REMODEL OR ADDITION TO THAT PROJECT OR FOR ANY OTHER PROJECT. /4\ /3\ /i\ Revisions: Sheet Title: PLAY FIELD STORMWATER DRAINAGE PLAN Designed by: Drawn bv: Checked bv: JAD JAD DCN Sheet No. C1 02 of 05 Sheets [DEVELOPMENTao���=�=a°o TALBOT HILL ELEMENTARY SCHOOL A PORTION OF THE NE 1/4 OF THE NE 1/4 OF SEC. 30, TWNm 23 N., o RGEm 05 E. W.M. CITY OF RENTON, KING COUNTY, WASHINGTON. � v N EROSION AND SEDIMENT CONTROL ESC STANDARD PLAN NOTES: i l THEF I A LISTING F RA NOTES T I IN H I T T FOLLOWING S LL9 NG D GENE L O ES THA SHALL BE INCORPORATED THE EROSION AND SEDIMENT CONTROL ESG PLAN SET ALL THE NOTES ON THE { 1 LIST MAY NOT PERTAIN TO EVERY PROJECT THE APPLICANT OR OWNER, HEREBY REFERRED TO AS APPLICANT, MAY STRIKE OUT IRRELEVANT NOTES IF NOT APPLICABLE TO THE PROJECT. HOWEVER. THE APPLICANT SHALL NOT RENUMBER NOR EDIT THE REMAINING NOTES. IF ADDITIONAL NOTES ARE NEEDED FOR SPECIFIC ASPECTS, THEY SHALL BE ADDED AFTER THE ESC STANDARD PLAN NOTES. 1. BEFORE ANY CONSTRUCTION OR DEVELOPMENT ACTIVITY CCCURS, A PRE -CONSTRUCTION MEETING SHALL BE FIELD AMONG THE CITY OF RENTON. HEREBY REFERRED T4 AS THE G1TY, THE APPLICANT, AND THE APPLICANTS CONTRACTOR 2. THE APPL ICANT 15 RESPONSIBLE FOR OBTAINING THE WAS HINOTON STATF DEPARTMENT OF ECOLOGY IECOLOGY) CONSTRUCTION STORMWATER GENERAL PERMIT, IF IT IS REWIRED FOR THE PROJECT THE APPLICANT SHALL PROVIDE THE CITY COPIES OF ALL MONITORING REPORTS PROVIDED TO ECOLOGY ASSOCIATED WITH THE CONSTRUCTION S70RUWA1ER GENERAL PERMIT 3. THE ESC PLAN SET SHALL INCLUDE AN ESC CONSTRUCTION SEOUE,14CE DETA LNG THE ORDERED S7EPS THAT SHALL BE FOLLOWED FROM CONSTRUCTION WMM ENC£MENT TO POST -PROJECT CLEANUP IN ORDER TO FULFILL PROJECT ESC REQUIREMENTS. 4 THE BOUNDARIES OF THE CLEARING LIMITS, SENSITIVE AREAS AND THEIR BUFFERS. AND AREAS OF VEGETATION PRESERVATION AND TREE RETENTION AS PRESCRIBED ON THE PLANKS) SHALL BE CLEARLY DELINEATED BY FENCING AND PROTECTED IN THE FIELD IN ACCORDANCE WITH APPENDIX D OF THE CFTY OF RENTON SURFACE WATER DESIGN MANUAL (RENTON SVJDM) PRIOR TO THE START OF CONSTRUCTION. DURING THE CON57RUCTION PERICO, NO DISTURBANCE BEYOND THE CLEARING LIMITS SHALL RE PERMITTED, THE CLEARING LIMITS SHALL BE MAINTAINED BY THE APPLJCANTIESC SUPERVISOR FOR THE DURATION OF CONSTRUCTION. S. STABILIZED CONSTRUCTIDN ENTRANCES SHALL BE INSTALLED AT THE BEGINNING OF CONSTRUCTION AND MAINTAINED FOR THE DURATION OF THE PROJECT ADDITIONAL MEASURES. SUCH AS CONSTRUCTED WI-IEEL WASH SYSTEMS OR WASH PADS, MAYBE REQUIRED TO ENSURE THAT ALL PAVED AREAS ARE KEPT CLEAN AND TRACK -OUT TO ROAD RIGHT OF WAY DOES NOT OCCUR FOR THE DURATION OF THE PROJECT. IF SEDIMENT IS TRACKED OFFSITE, PUBLIC ROADS SHALL BE CLI=ANEO THOROUGHLY AT THE END OF EACH DAY, OR MORE FREQUENTLY DURING WET WEATHER, AS NECESSARY TO PREVENT SEDIMENT FROM ENTERING WATERS OF THE STATE. B. WASHOUT FROM CONCRETE TRUCKS SNAIL 3E PERFORMED OFF -SITE OR IN DESIGNATED CONCRETE WASHPUT AREAS ONLY. DO WASH OUT OONGRE'T£ T H Y TRUCKS ONTO THE GROUND. OR TO STORM DRAMS OR OPEN PRC ES. ON -SITE DUMPING OF EXCESS CONCRETE SHALL ONLY UCCVIi IN DESIGNATED CONCRETE WASHOUT AREAS. I 7 ALL REQUIRED ESC BMPS SHALL BE CONSTRUCTED AND IN OPERATION PRIOR TO LAND CLEARING AN[7+OR CONSTRUCTION TO PREVENT TRANSPDRTAT ON OF SEDIMENT TO SURFACE WATER, DRAINAGE SYSTEMS AND ADJACENT PROPERTIES. ALL ESC BMPS SHALL BE MAWTAI NED IN A BAT ISFACTORY CONDITION UNTIL SUCH TIME THAT CLEARING ANDR3R CONSTRUCTION fS COMPLETE AND POTENTIAL FOR ON -SITE EROSION HAS PASSED. ALL ESC SMPS SHALL SE REMOVED AFTER CONSTRUCTION IS COMPLETED AND THE SITE HAS SEEN STABILIZED TO ENSURE POTENTIAL FOR ON-B1TE EROSION DOES NOT EXIST THE IMPLEMENTATION, MAINTENANCE. REPLACEMENT ENHANCEMENT AND REMOVAL ESC BMPS SHALL BE THE RESPONSIBIL OF THE APPLICANT , OF RY B. ANY HAZARDOUS MATERIALS pR LIO UIO PRODUCTS THAT HAVE THE POTENTIAL TO POLLUTE RUNOFF SHALL BE DISPOSED OF PROPERLY B. THE ESC 13MPS MPICTED ON THIS DRAV014G ARE INTENDED TO BE MINIMUM REQUIREMENTS TO MEET ANTICIPATED SITE CON OITIONS AS CONSTRUCTION PROGRESSES AND UNEXPECTED OR SEASONAL CONDITIONS DICTATE. THE APPLICANT SHALL ANTICIPATE THAT MORE E SC BMPS WILL BE NECESSARY TO ENSURE COMPLETE SILTATION CONTROL ON THE PROPOSED SITE DURING THE COURSE OF CONSTRUCTION, IT SHALL BE THE OBLIGATION AND RESPONS481LITY OF THE APPLICANT TO ADDRESS ANY NEW CONDITIONS THAT MAYBE CREATED BY THE ACTIVITIES AND TO PROVIDE ADDITIONAL ESC BMPS, OVER AND ABOVE MINIMUM REQUIREMENTS. AS MAY BE NEEDED. TO PROTECT ADJACENT PROPERTIES AND WATER QUALITY OF THE RECEIVING ORANAGE SYSTEM. 10. APPROVAL OF TAUS PLAN IS FOR ESC ONLY. IT DOES NOT CONSTRTJTE AN APPROVAL OF STORM DRAINAGE DE515N, SIZE NOR LOCATION OF PIPES. RESTR IMPS, CHANNELS. OR STORMWATER rppLITIES. 11 ANY DEWATE RWS SYSTEM NECESSARY FOR THE CONSTRUCTION OF STORMWATER FACFLTIES SHALL BE SUBMI TEA TO THE CITY FOR REVIEW AND APPROVAL. 12 ANY AREAS OF EXPOSED SOILS, INOLUONG ROADWAY EMDMXMENTS, THAT WILL NOT BE DLSTURBEO FOR TWO DAYS DURN43 THE WET SEASON IOCTOBER 16T THROUGH APRIL 30TH) OR SEVEN DAYS DURING THE DRY SEASON IMAM 1ST THROUGH SEPTEMBER BOTH) SHALL BE IMMEDIATELY STABILIZED WITH THE APPROVED ESC COVER METHODS (E G.. SEEDING, MULCHING- PLASTIC COVERING. ETC.) IN CONFORMANCE WITH APPENDIX 0 OF THE RENTON SWDM. 13. WET SEASON ESC REQUIREMENTS APPLY TO ALL CONSTRUCTION SITES BETWEEN OC70SER 1ST AND APPLL BOTH. UNLESS OTHERWISE APPROVED BY THE CITY. 14 ANY AREA NEEDING AaC 10NAL ESC MEASURES, NOT REQUIRING IMMEDIATE ATTENTION, SHALL BE ADOR ESSED WITHIN SEVEN (7) DAYS. 1 S THE ESC BMPS ON INACTIVE SITES SHALL BE INSPECTED A1410 MAINTAINED AT A MINIMUM Or ONCE'A MONTH OR WITHIN Zi HOURS FOLLOWINGA STORM EVENT. INSPECTION AND MAINTENANCE SHALL OCCUR MORE FREQUENTLY AS REQUIRED BY THE CRY 19. BEFORE COMMENCEMENT OF ANY CONSTRUCTIDN ACTLNTY, CATCH BASIN INSERTS PER THE CRY STANDARD PLAN 248-30 SHALL BE PROVIDED FOR ALL STORM DRAIN. INLETS DOWNSLOPE AND WITHIN 500 FEET OF A DISTURBED OR CONSTRUCTION AREA, UNLESS THE RUNOFF THAT ENTIERS THE INLET WILL BE CONVEYED TO A SENMENT POND OR TRAP ALL CATCH BASIN INSERTS SHALL BE PERIODICALLY INSPECTED AND REPLACED AS NECESSARY TO ENSURE FULLY FUNCTIONING CONDITION 17. AT NO TIME SHALL SEDIMENT ACCUMULATION EXCEED 2A OF THE CAPACITY OF THE CATCH BASIN SUMP. ALL CATCH BASINS AND CONVEYANCE ONES SHALL BE CLEANED PFNCOR TO PAVING TIME CLEANING OPERATION SHALL NOT FLUSH SEDIMENT -LADEN WATER INTO THE DOWNSTREAM SYSTEM. 13. ANY PERMANENT STORMWATER FACILITY LOCATION USED AS A TEMPORARY SETTLING RA51N SHALL BE MODIFIED WITH THE N ECESSARY ESC SNIPS AND SHALL PROVIDE ADEQUATE STORAGE CAPACITY. IF THE TEMPORARY FAC ILITY IS TO ULTIMATELY FUNCTION AS AN INFILTRATION SYSTEM IN ITS PERMANENT STATE, THE TEMPORARY FACILITY SHALL BE ROUGH GRADED 50 THAT THE BOTTOM AND SIDES ARE AT LEAST THREE FEET ABOVE THE FINAL GRADE OF THE PERMANENT FACILITY. T F A 19 AREAS DESIGNATED ON TIME PLANS CONTAINING EXl3 LNG STORMWATER ACILRIEB OR ON -SITE BMPS AMENDED SOILS 0lORETENTIC44. PERMEABLE PAVEMENT. ETC) SHALL BE CLEARLY FENCED AND PROTECTED USING ESC BMPS TO AVOID SEDIMENTATION AND COMPACTION OUR ING CONSTRUCTION 20. PRIOR TO THE BEGINNING OF THE WET SEAM (QCTOBM TST). ALL DISTURBED AREA& SHALL M INSPECTED TO IDENTIFY WHICH ONES SHALL BE 80012D OR SEE CEO W PREPARATION FOR THE WINTER RAINS. DISTURBED AREAS SHALL BE SODOM OR SEEDED W ITH IN CNE WEEK OF THE BEGINNING Or THE WET SEASON. AN "HIBIT OF THOSE AREAS TO M WOOED OR SEEDER AND THOSE AREAS YO REMAIN UNCOVERED SHALL BE SUBMITTED TO THE CITY FOR REVIEW. SI PRIOR TO RNAL CONSTRUCTION ACCEPTANCE, TILE PROJECT SITE SHALL BE STABILIZED TO PREVENT SEDIMENT -LADEN WATER FROM LEAVING THE PROJECT SITE, ALL ESC BMPS SHALL BE REMOVED, AND STORMWATER CONVEYANCE SYSTEMS. FACILITIES. AND ON -SITE EMIRS SHALL 13E RESTORED TO THEIR FULLY FUNCTIONING CONDITION. ALL DISTURBED AREAS OF THE PROJECT SITE SHALL BE VEGETATED OR OTHERWISE PERMANENTLY STABILIZED. AT A MINIMUM. DISTURBED AREAS SHALL BE SODDED OR SEEDED AND MULCHED TO ENSURE THAT SUFFICIENT COVER WILL DEVELOP SHORTLY AFTER FINAL APPROVAL MULCH WITHOUT SEEDING IS ADEQUATE FOR AREAS TO BE LANDSCAPED BEFORE OCTOBER I ST. 22 ROCKERIES ARE CONSIDERED TO BE A METHOD OF BANK STABI UZATION AND EROSION CONTROL. ROCKERIES SHALL NOT BE CONSTRUCTED TO SERVE AS RETAINING WALLS. ALL ROCKERIES IN C ITY ROAD RFGMTSOF-WAY SHALL BE CONSTRUCTED IN ACCORDANCE WITH CITY STAN OARM. ROCKER) ES OUTSIDE OF :TOAD RIGHTS ­OF -WAY SNAIL BE QONSTRVCTEC IN ACCORDANCE WITH THE INTERNNATIQNAL BUILDING CODE UNLESS OTHERWLSr NOTED, GRAWING IS NOT TO SCALY INT51 STD. PLAN - 268.00 a PUBLIC WORKS EROSION AND SEDIMENT CONTROL ° DEPARTMENT STANDARD PLAN NOTES GAS 9/28/2018 ] DATE �TESC STANDARD �NOTES / NOT TO SCALE 0 Know what's below. Call before you dig. SURFACE WATER STANDARD PLAN NOTES: THE FOLLOWING 16 A LISTING OF GENERAL NOTES THAT SHALL BE INCORPDRATEO IN THE ORAINAGE PLAN SET. ALL THE NOTES ON THE LIST MAY NOT PERTAIN TO EVERY P APPLICANT Y RR T P T Y T T R F T A Y T . HOWEVER. TH ROJEGT THE UGAN OR OWNER, HEREBY REFE ERRED TO AP UCAN , MAY STRIKE KE OUT IRRELEVANT NOTES I NO APPLICABLE D THE PROJECT OWEVE E APPLICANT SHALL NOT RENUMBER NOR EDIT THE REMAINING NOTES. IF ADDITIONAL NOTESARE NEEDED FOR SPEC IF IC ASPECTS. THEY SHALL BE ADDED AFTER THE SU RF ACE WATE R STANDARD PLAN NOTES I BEFORE ANY CONSTRUCTION OR DEVELOPMENTACTIVRY OCCURS, A PRE -CONSTRUCTION MEETING SHALL BE HELD AMONG THE CITY OF RENTON, HERESY REFERRED TO AS THE CITY, THE APPLICANT, AND THE APPLICANT'S CONTRACTOR. 2 THE APPLICANT SHALL W RESPONSIBLE FOR SECURING ALL NECESSARY CITY. STATE. AND FEDERAL PERMITS PRIOR TO CONSTRUCTION. 3 ALL STORM DRAINAGE IMPROVEMENTS SHALL BE DESIGNED AND CONSTRUCTED IN ACCORDANCE WFTH THE LATEST EDITION OF THE CITY OF RENTON SURFACE WATER DE 34GN MANUAL (RENTON SWDM), RENTON MUNICIPAL CODE (RMC), AND THE STANDARD SPECIFICATIONS FOR ROAD, BRIDGE AND MUNICIPAL CONSTRUCTION PREPARED BY WSDOT AND THE AMERICAN FUBLIC WORKS ASSOCIATION (APWA), IT SMALL BE THE SOLE RESPONSIBILITY OF THE APPLICANT TO CORRECT ANY ERROR. OMISSION OR VARLAT10N FROM THE ABOVE REQUIREMENTS FOUND IN THE PLANS. ALL CORRECTIONS SHALL BE AT NO ADDITIONAL COST TO THE CITY 4 APPROVAL OF THE ROAD. GRADING. PARKING, BUILDING. AND DRANAGE PLAN DOES NOT WNSTITLITE AS APPROVAL OF ANY arMER CONSTRUC 1M (E.G. WATER, SEWER, GAS, ELECTRICAL ETC.). PLANS FOR STRUCTURES SUCH AS BRIDGES. VAULTS. AND RETAINING WALLS REQUIRE A SEPARATE REVIEW AND APPROVAL BY THE CITY PRIOR TO CONSTRUCTION. THE SURFACE WATER DRAINAGE SYSTEM SHALL BE CONSTRUCTED ACCORDING TO THE APPROVED PLANS. ANY DEVIATION FROM THE APPROVED PLANS WILL REO UIRE COORDINATION FOLLOWED BY WRITTEN APPROVAL FROM THE CITY. 5. A COPY OF THE APPROVED PLANS SHALL RE ON THE JOB SITE WHENEVER CONSTRUCTN]N 15 IN PROGRESS. 6 THE LOGATFONS OF ALL EXISTING UTI.4TIES SHOWN HEREON HAVE RFFN £STABUSHEA 13Y FIELD SURVEY OR OBTAHNEP FROM AVAILABLE RFGORpS AND SHALL THEREFORE BE CONSIDERED APPROXIMATE ONLY AND NOT NECESSARILY COMPLETE. IT IS THE SOLE RESPONSES ILITY OF THE APPLICANT AND THE APPLICANTS F Y CONTRACTOR TO INDEPENDENTLY VERIFY THE ACCURACY 0 ALL UTILITY LOCATIONS SHOWN AND TO FURTHER DISCOVER AND AVOID AN OTHER UTILITIES NOT SHOWN HEREON THAT MAY BE AFFECTED BY THE IMPLEMENTATION OF THIS PLAN, THE APPLICANT SHALL RECORD ON THE AS -BUILT DRAWINGS ALL UNDOCUMENTED UTILITIES DISCOVERED AND ANY CHANGES TO THE APPROVED PLANS. THE APPLICANT SHALL IMMEDIATELY NDTIr Y THE ENGNEER OF RECORD IF A CON RJCT EX18 TS. 7 VERTICAL DATUM SHALL BE NAVD SB AND HORIZONTAL DATUM SHALL BE NAD 83 (WA STATE PLANE- NORTH), UNLESS OTHERWISE APPROVED BY THE CRY REFERENCE BENCHMARK. DATUM. AND ELEVATIONS SHALL BE NOTED ON THE PLANS. 0 ALL UTILITY TRENCH BACKFILL AND ROADWAY SUBGRADE SHALL BE COMPACTED TO 95%MAXIMUM DRY DENSITY PER SECTION 2.03.3(1410 -COMPACTION AND MCISTURE CONTROL. TESTS.OF THE WSDOT STANDARD SPECIFICATIONS. IN PERMEABLE PAVEMENT AND OTHER INFILTRATION AREAS, ALL TRENCH SACKFAL SHALL BE FIRM ANO UNYIELDING BUT IN NO CASE SHALL BE COMPACTED TO MORE THAN 92%OF MAXIMUM DRY DENSITY 9 OPEN CUTTING OF EXISTING ROADWAYS FOR STORM DRAINAGE WORK IS NOT ALLOWED UNLESS SPEORCALLY APPROVED BY THE CRY AND NOTED ON THESE APPROVED PLANS. ANY OPEN CUT SHALL BE RESTORED IN ACCORDANCE WITH THE CITY TRENCH RESTORATION STANDARDS, 1G ALL PIPE AND STRUCTURES SHALL BE STAKED FOR SURVEY LINE AND GRADE PRIOR TO THE START OF CONSTRUCTION. WHERE SHOWN ON THE PLANS OR WHERE DIRECTED BY THE CITY, THE EXISTING MANHOLES, CATCH BASINS, OR INLETS SHALL BE ADJUSTED TO THE GRADE AS STAKED. 11 ALL FLOW CONTROL FAC4LFTIES SHALL BE INSTALLED AND IN OPERATION PRIOR TO, OR IN CGNJUINCTION WITH, ANY CONSTRUCTION ACTIVITY UNLESS OTHERWISE APPROVED BY THE CITY. 12 ALL PIPE AND APPV RTENANCES SHALL BE LAID ON A PROPERLY PREPARED FOUNDATION IN ACCORDANCE WITH THE CURRENT STATE OF WASHINGTON STANDARD SPECIFICATION FOR ROAD AND BRIDGE CONSTRUCTION. THIS SHALL INCLUDE NECESSARY LEVELING OF THE TRENCH BOTTOM OR. THE TOP OF THE FOUNDATION MATERIAL, AS WELL AS PLACEMENT AND COMPACTION OF REQUIRED BEDDING MATERIAL TO UNIFORM GRADE SO THAT THE ENTIRE LENGTH OF THE PIPE WILL BE SUPPORTED ON A UNIFORMLY DENSE, UNYIELDING BASE. ALL PIPE BEDDING AND SACKFILL SHALL BE AS SHOWN ON THE CITY STANDARD PLAN 220-00. 413.1A AND 220213 13 STEEL PIPE SHALL BE ALUMINIZED, OR GALVANIZED WITH ASPHALT TREATMENT 1, 2, OR S INSIDE AND OUTSIDE 14. ALL DRAINAGE STRUCTURES SUCH AS CATCH BASINS AND MANHOLES SHALL BE FITTED WITH DUCTILE IRON. BOLT-LCCKING LIDS PER THE CITY STANDARD PLAN 204.10. 2042D, 204.90, 204.4T1. AND 204.60. STRUCTURES SHALL WAVE • RECTANGULAR OR ROUND. SOLID LIDS WHEN NOT COLLECTING RUNOF F. AND OUTSIDE OF THE ROADWAY • ROUND, SOLID LIDS WHEN NOT COLLECTING RUNOFF, AND LOCATED WITHIN THE ROADWAY, BUT OUTSIDE OF THE CURBIGUTTER LINE- . ROUND, SOLID LIDS DISPLAYING TH:E CITY LOGO WHEN WFIH!N THE PUBLIC RIGHT-0E-WAY OR 1N AN EASEMENT TO THE CITY. PRIVATE STRUCTURE LIDS OUTSIDE PUBLIC RIGHT-OF-WAY AND EASEMENTS TO THE CITY SHALL NOT D15PLAY THE CITY LOGO. IS SUELDINGS AND OTHER STRUCTURES SWILL BE PLACED IN ACCORDANCE WITH TABLE 4 1 EASEMENT WIDTHS AND BUILDING SETSACKS UNES OF THE RENTON SWDM 19 LIDS OF MANHOLESICATCH BASINS WITHIN PUBLIC RIGHT-OF-WAY SHALL NOT BE ADJUSTED TO FINAL GRADE UNTIL AFTER PAVING. ALL MANHOLEeCATCH BASIN RIMS SHALL BE ADJUSTED TO BE FLUSH 1V11T-1 F INAL FINISHED GRADES, UNLESS OTHERWISE SHOWN 17 ALL DRIVEWAY CULVERTS LOCATED WITH IN CITY RIGHT# -WAY SHALL BE OF SUFRC IENT LENGTH TO PROVIDE A MINIMUM 3:1 SLOPE FROM THE EDDE OF THE DRIVEWAY TO THE BOTTOM OF THE DITCH UNLESS OTHERWISE NOTED, DRAW I NG IS NOT TO SCALE I053 STD. PLAN - 267.00 pUBUCwaRKs SURFACE WATER STANDARD PLAN by DEPARTMENT NOTES {1 OF 2) artin Pastuchas/13/2ozn g}d(. DATE �STORMWATER �DR�ANAGE NOTES L / NOT TO SCALE DRAINAGE GRATE GRATE FRAME _ SEDIMENT AND DEBRIS FILTERED WATER - SECTION VIEW DRAINAGE GRATE (RECTANGULAR GRATE SHOWN) BELOW INLET GRA7E DEVICE F MAX TRIM OVER F LOW BYPASS BELOW INLET GRATE DEVICE RETRIEVAL SYSTEM CTYPJ OVERFLOW BYPASS ITYP.) ISOMETRIC VIEW NOTES: I PROTECTION SHALL BE PROVIDED FOR ALL STORM 13RALN INLETS DOWNSLOPE AND WITHIN 50O FEET OF A DISTURBED OR CONSTRUCTION AREA, UNLESS THE RUNOFF THAT ENTERS THE CATCH BASIN WILL BE CONVEYED TO A SEDIMENT POND OR TRAP. 2. INLET PROTECTION SWILL SE USED TO PROTECT THE DRAINAGE SYSTEM. 3. THE CONTRIBUTING DRAINAGE AREA MUST NOT BE LARGER THAN ONE ACHE. 4. SIZE THE BELOW INLET GRATE DEVI CE IBJGDI FOR THE STORMWATER STRUCTURE IT WILL SERVICE- 5- THE BFGD SHALL HAVE A BUILT-IN HIGH -FLOW RELIEF SYSTEM (OVERFLOW BYPASS} 6- THE RETRIEVAL SYSTEM MUST ALLOW REMOVAL OF THE "D WITHOUT SPILLING THE. COLLECTED MATERIAL. T PERFORM MAINTENANCE IN ACCORDANCE WITH STANDARD SPECIFICATION 8.01.305). 8. ANY SEDIMENT N THE CATCH BASIN INSERT SHALL BE REMOVED WHEN THE SEDIMENT HAS FILLED ONE-TH1RO OF THE AVAILABLE STORAGE THE FILTER MEDIA FOR THE INSERT SHALL BE CLEANED OR REPLACED AT LEAST MONTHLY. UNLE55 OTINERWI5E NOTED, DRAWING 15 NOTTO SCALE IITTSI STD. PLAN - 216"30 PUBLIC WORKS CATCH BASIN INSERT APR L : 9/28/2018 1 DEPARTMENT GAZ DATE CATCH BASIN INSERT 4 NOT TO SCALE SURFACE WATER STANDARD PLAN NOTES: THE FOLLOWING IS A LISTING OF GENERAL NOTES THAT SHALL BE INCORPORATM A THE ORAINAGE PLAN SET- ALL THE NOTES ON THE LIST MAY NOT PERTAIN TO EVERY PROJECT THE APPLICANT OR OWNER. HEREBY REFERRED TO AS APPLICANT, MAY STRIKE OUT IRRELEVANT NOTES IF NOT APPLICABLE TO THE PROJECT. HOWEVER. THE APPLICANT SHALL NOT RENUMBER NOR EDIT THE REMAINING NOTES. IF ADDITIONAL NOTESARE NEEDED FOR SPECIFIC ASPECTS. THEY SHALL BE ADDED AFTER THE SURFACE WATER STANDARD PLAN NOTES 18 ROCK FOR EROSION PROTECTION OF ROADSIDE DITCHES. WHERE REQUIRED, SHALL BE OF SOUND QUARRY ROCK PLACED TO A MINIMUM DEPTH OF ONE R I I FOOT AIND SHALL MEET THE FOLLOWING SPECIFICATIONS. . 4 - B INCH ROCK 140 - 70% PASSI NG, . 2 - 4 NMI ROCK 130 - 40% PASSING; AND . LESS THAN 2INCH ROCK 110. 20% PASSING. 19 FOOT NG DRAINAGE SYSTEMS AND ROOF DOWNSPOUT SYSTEMS SHALL NOT BE INTERCONNECTED AND SHALL SEPARATELY CONVEY COLLECTED FLOW TO THE CONVEYANCE SYSTEM OR FLOW CONTROL FACILITY ON THE SITE, UNLESS APPROVED BY THE CRY. FOOTING DRAINS SHALL NOT BE CONNECTED TO ON -SITE BMPS. :V. THE END OF EACH STORM DRAIN STUB SHALL BE CAPPED. A CLEANOUI TOPPED WITH A BOLT -LOCKING LID MARKED 'STORM' OR'DWUN" SMALL BE LOCATED AT THE PROPERTY LINE OR AT THE POINT OF CONNECTION OF A PRIVATE STORM DRAINAGE CONVEYANCE SYSTEM PER THE CITY STANDARD PLAN 227.00. 11. ALL STORM SYSTEM EXTENSIONS SHALL BE STAKE[) FOR LINE AND GRADE BY A SURVEYOR LICENSED IN WASHINGTON STATE, AND CUT SHEETS SHALL BE PROVIDED TO THE CITY PRIOR TO CONSTRUCTION. 22 ALL NEWLY -INSTALLED AND NEWLY -REHABILITATED (PUBLIC AND PRIVATE) STORM CONVEYANCE SYSTEMS SHALL BE INSPECTED BY MEANS OF REMOTE CCTV ACCORDING TO THE CITY STANDARD PLAN 2W.06. CCTV INSPECTIONS AND REPORTS SHALL BE SUBMITTED TO THE CITY PRIOR 70 RECEIVING APPROVAL TO INSTALL PROJECT CURBS GUTTERS ANDIOR PAVEMENT 23. ALL STORM SYSTEMS AND CONNECTIONS TO EL[ST1NG MAINS SHALL BE TESTED IN ACCORDANCE WITH SECTION7-04.3 1 OF THE WSDOT STANDARD SPECIFICATIONS f7 A14P IN THE PRESENCE OF A REPRESENTATIVE OFTHE CITY. STORM DRAIN STUBS SHALL BE TESTED FOR ACCEPTANCE AT THE SAME TIME THE MAIN STORM JS TESTED, 24. FOR ALL DISTURBED PERVIOUS AREAS KCOMPACTED, GRADED, LANDSCAPED. ETC.) OF THE DEVELOPMENT SITE, TO MAINTAIN THE MOISTURE CAPACITY OF THE SOIL EITHER STOCKPBE AND REDISTRIBUTE THE EXISTING DUFF LAYER AND NATIVE TOPSOIL OR AMEND THE SOIL WITH COMPOST IN ACCORDANCE WITH STANDARD PLAN 284 DO JS ISSUANCE OF THE BUILDING OR CON5TRUCTH]N PERMITS BY THE CITY DOES NUT RELIEVE THE APPLICANT OF THE CONTINUING LEGAL OBLIGATION IWDIOR LIABILITY CON 4EC7EO MATH STORMWATER DISPOSAL. THE CITY DOES NOT ACCEPT ANY OBLIGATION FOR THE PRDPER FUNCTIONING AND MANTENANCE OF THE STORM SYSTEM PROVIDED DURING CONSTRUCTION. !, 26 ADEQUATE WEGU,ARDS, SAFETY DEVICES. PROTECTIVE EOUIPMENT. FLAGGERS, AND ANY OTHER ACTIONS HEEDED TO PROTECT THE LIFE, HEALTH. AND SAFETY OF THE PUBLIC. AND TO PROTECT PROPERTY IN CONNECTION WITH THE PERFORMANCE OFF WORK SHALL BE PROVIDED. ANY WORN WITHIN THE TRAVELED RIGHT-OF-WAY THAT MAY INTERRUPT NIDRMAL SHALL FLOW S1 REQUIRE A TRAFFIC CONTROL PLAN APPROVED By THE CITY ALL SECTYONS df YIHE WSDgT STANDARD SPECIFICATIONS 1-10 TEMPORARY TRAFFIC CONTROL SHALL APPLY 27. PROJECTS LOCATED WITHIN THE CITY'%AQUIFER PROTECTION AREA (APA) SHALL COMPLY WITH SPECIAL REQUIREMENT 05 OF THE RENTON SWUM AND AQUIFER PROTECTION REGULATIONS [RUC 4-3.0601. 2B. PLACEMENT OF SURFACE APPURM AANES (CATCH BASINIMANHOLE LIDS, CLEN40UTS, INLETS, ETC.) IN THE STREET TRAVEL LANE WHEEL PATH.INTrMSECTIONS Of STREET TRAVEL LANES, BIKE LANES. SIDEWALKS. AND CROSSWALKS SHALL Be AVOIDED WHENEVER POSSIBLE. ANY SUIV=AM APPURTENANCE PLACED IN A SIDEWALK OR CROSSWALK SHALL BE FITTED WITH A NONSLIP OR NON-61KID LID PER ADA REOUIREM ENTS. "d CLEARLY LABEL PUBLIC AND PRIVATE SYSTEMS ON THE WRNS. PRIVATE SYSTEMS SHALL BE MAINTAINED BY THE APPLICANT. 39. MINIMUM COVER OVER STORM DRAINAGE PIPE SHALL CONFORM TO TABLE 4-2.1A2 OF THE RENTON SWOM 31 CONSTRUCTED PERMEABLE PAVEMENT SHALL BE PERMEABLE ENOUGH TO ABSORB WATER AT A MINIMUM RATE OF 20 INCHES PER HOUR IMMEDIATRY AFTER THE PAVEMENT SURFACE HAS BEEN W'ETTE D CONTINUIDUSLY FOR AT LEAST 10 MINUTES. COMPLIANCE WITH TH15 MINIMUM RATE SHALL. BE CHECKED PRIOR TO CONSTRUCTION APPROVAL OF THE PAVEMENT COMPLIANCE MAY BE CHECKED USING A 8IMPLE BUCKET TEST IN WHICH 5 GALLONS OF WATER IS POURED ONTO THE PAVEMENT SURFACE ALL AT ONCE. IF ONLY A MINOR AMOUNT OF WATER PONDS OR RUNS OFF THE SURFACE, THEN THE PAVEMENT IS CONSIDERED TO MEET THE MINIMUM RATE OF ABSORPTION AT LEAST ONE TEST SHALL BE CONDUCTED PER 1,000 SQUARE FEET OF PERMEABLE PAVEMENT. IF THIS TEST IS NOT CONCLUSIVE. THEN ANOTHER TEST PER ASTM C1TT)1 SHALL BE CONDUCTED. FOR LARGE AREAS IN3.G., PARKING AREAS), TESTING OBSERVATION MAY BE ACCOMPLLSHED WHILE WALKING 13EMIND A SLOWLY MOVING WATER TRUCK DISCHARGING WATER AT A RATE SIMILAR TO THE BUCKET TEST. PERMEABLE PAVERS 94ALL13E TESTED USING ASTM C1781. UNLESS OTH ER W ISE NOTED, DRAW I NG IS NOT TO SCALE I NUS) STD. PLAN - 267.10 PUBLIC WORKS SURFACE WATER STANDARD PLAN iRldby: DEPARTMENT NOTES (2 OF 2) arltiin Pastuch /�3�zoz� h +URyww= DATE JOINTS IN FILTER FABRIC SHALL BE SPLJCED AT POSTS. USE STAPLES, WIRE RINGS, OR EQ W VALENT TO ATTACH FABRIC TO POST S _ 2"A2" 14 GAUGE WIRE.OR -- - - - ECILINAL ENT. IF STANDARD STRENGTH FABRIC USED FILTER FABRIC T MIN, B' MAX. -I POST SPACI NG MAY BE INCREASED4'x4' MIN, TRENCH I I 12" MIN - TO F IF WIRE SACKING IS USED I II 'L-EV SACKFILL TRENCH WITH NATIVE SOIL OR XW TO 1-V2' WASHED GRAVEL 2"IRA' WOOD POSTS; STEEL FENCE POSTS, OR EC DIVALENT KTYP I NOTES: 1. CONDRTGNS OF LISE I.1 SILT FENCE MAY BE USED DOWNSLOPE OF ALL DISTURBED AREAS. 1.2 SILT FENCE IS NOT INTENDED TO TREAT CONCENTRATED FLOWS. NOR IS IT INTENDED TO TREAT SUBSTANTIAL AMOUNTS OF OVERLAND FLOW. ANY CONCENTRATED FLOW MUST BE CONVEYED THROUGH THE DRAINAGE SYSTEM TO A SEDIMENT TRAP OR POND. 2. DESIGN AND INSTALLATION SPECIFICATIONS 2.7. THE GEOTEXTILE USED MUST MEET THE STANDARD LISTED BELLOW. A COPY OF THE MANUFACTURERS FABRIC SPECIFICATIONS MUST BE AVAILABLE ON SITE. ACTS (ASTM 04751) 30.100 SIEVE SIZE [IPAM. 1lxn ) FOR SILT FILM 50-1 30 SIEVE SIZE 15.30-0.15MMj FOR OTHER FABRICS WATER PERMITTIVITY IASTM D44S1) D.02 SEC' MINIMUM GRAB TENSILE STRENGTH (ASTM 04932I $80 LBS. MIN. FOR EXTRA STRENGTH FABRIC $00 LBS. MIN. FOR STANDARD STRENGTH FABRIC GRAB TENSILE ELONGATION (ASTM 134592) 3D% MARK. (WOVEN I ULTRAMDLETRESISTANCE{ASTM 04355) 70% MIN. 22. STANDARD STRENGTH FABRIC REQUIRES WIRE BACKING 10 INCREASE THE STRENGTH OF THE FENCE. WIRE SACKING OR CLOSER POST SPACING MAY BE REOUFRED FOR EXTRA STRENGTH FABRIC IF FIELD PERFORMANCE WARRANTS A STRONGER FENCE. 2.3. WHERE THE FENCE IS INSTALLED. THE SLOPE SHALL NOT BE STEEPER THAN ZH:I V 2.4. IF A TYPICAL SILT FENCE IS USED. THE STANDARD -PYA' TRENCH MAY BE REDUCED AS LONG AS THE BOTTOM 8 INCHES OF THE SILT FENCE FABRIC IS WELL BURIED AND SECURE IN ATRENCH THAT STABI LIZES THE FENCE AND DOES NOT ALLOW WA7ER TO BYPASS OR UNDERMINE TIC SILT FENCE. 2.6- FILTER FABRIC FENCES SHALL BE INSTALLED ALONG CONTOURS WHENEVER POSSIBLE 9- MAINTENANCE STANDARDS 3.1. ANY DAMAGE SHALL BE REPAIRED IMMEOATELY. 3.2. IF CONCENTRATED FLOWS ARE EVIDENT UPHILL OF THE FENCE, THEY MUST BE INTERCEPTED AND CONVEYED TO A SEDIMENT TRAPOR POND- 3.3. IT IS IMPORTANT TO CHECK THE U PHILL SIDE OF THE FENCE POR SIGNS OF THE FENCE CLOGGING AND ACTING AS A BARRIER TO FLOW AND THEN CAUSING CHANNELIZATION OF FLOWS PARALLEL TO THE FENCE. IF THI S OCCURS. REPLACE THE FENCE OR REMOVE THE TRAPPED SEDIMENT 3.4. SEDIMENT MUST BE REMOVED WHEN SEDIMENT IS 6 INCHES HK4H. 3.6. IF THE FILTER FABRIC jOEOTO(TILE) HAS DETERIORATED DUE TO ULTRAVIOLET BRE MI]C N, IT SHALL BE REPLACED. UN LESS DTHFRWi F IATTEO, DRAWING IS NCR TO WAU INTSj AoRtL STD. PLAN - 214.00 PUBLIC WORKS SILT FENCE R 9/z8/2018 ] DEPARTMENT GAZ DATE SILT FENCE NOT TO SCALE TRENCH WIDTH. PIPE ZONE BEDDING AND SEE )NOTE 3 8ACKFILL SEE NOTE 4 6' O.D. FOUNDATION LEVEL r FOUN DATION MATERIAL, 5 IF RECIUIRED. SEE NOTE 5 TRENCH MOTH. SEE NOTE 3 SPAN B' PIPE ZONE BEDDING AND aACKRLL. SEE NOTE N 4 7 RISE FOUNDATION LEVEL r FOUNDATION INTER JAL, 1 IF REQUIRED. SEE NOTE 5 IY PIPE - ARCH RIGID PIPE NOTES: 1 PIPF COMPACTION LIMITS SHOWN ON THIS PLAN ARE FOR PIPE CONSTRUCTION IN AN EMBANKMENT. FOR PIPE CONSTRUCTION. IN A TRENCH- THE HORIZONTAL LIMITS OF THE PIPE COMPACTION ZONE SHALL BE THE WALLS OF THE TRENCH. .. O.D. IS EpUAL TO THE OUTSIDE DIAMETER OF A PIPE OR THE OUTSIDE SPAN OF PIPE -ARCH. SEE STANDARD WSDOTIAPWA SPECIFICATIONS SECTION 2-0-A FOR TRENCH WIDTH. A PIPE ZONE BEDDING AND BACKFILL MATERIAL SHALL BE PLACED IN G LDDSE LAYERS AND COMPACTED TO 95% MAXIMUM DENSITY. 6 EXCAVATE UNSTABLE MATERIAL DOWN TO FIRM SOIL AND REPLACE WITH FOUNDATION MATERIAL CLASS AOR E PER STANDARD WSDOTAAAWA SPEC IrJCATIONS SECTION 9-03.1 T. GRAVEL SACKF ILL FOR PIPE ZONE BEDDING (WSDOT 9-03.12(3)I OR MAINTENANCE ROCK WVSDOT S-O3.9I4II PIPE TYPE MINIMUM PUBLIC? PRIVATE? ALLOWED IN PONE 1 COVERRFTN DFTHEAPA? CORRUGATED 20 YES YES YES STEEL PIPE BPI RAL RIB STEEL 2-0 YES YES YES PIPE PLAIN CONCRETE PIPE IPCP1 ZO NO YES NO REINFORCED CONCRETE PIPE 1.0 YES YES NO (RCP) DUCTILE IRON PIPE t.0 YE5 YES YES CIRCULAR PIPE DIAMETER MFNIMUMDISTANCE BETWEEN BARRELS 12" 10 24' 1 z- 30- TO 96' DIAMETER 13 1 Or TO 1 ST 48" PIPE -ARCH SPAN NBNIRLM DISTANCE BETWEEN BARRELS IV TO 36' 12- 43" TO 142' SPAN 13 146'70 IBIT 48" UNLESS OTH ER W ISE NOTED. DFA W I NG IS N UT TO SCALE I NTSI STD. PLAN - Z20.00 AvotbLPUI3LIC WORKS PIPE ZONE BEDDING AND APPROVED DEPARTMENT COMPACTION - RIGID PIPE MartinPastQLha 10/19/20 ' DATE PIPE BEDDING NOT TO SCALE I SEE STANDARD PLANS 110. 110.1. 110.2, AND 111 FOR PAVEMENT RESTORATION REQUIREMENTS SU RF ACE RESTORATION AS I SPECIFIED IN CONTRACT DOCUMENTS ---- 12' MIN.--- EXISTING PAVEMENT SLIRFAL-L- `__----- -_-__- &• MIN , SEE NOTE 4 v NEAT LINE TRENCH -CRU5NED 51JRFACING TOP COU]i5E-PER WSDOT STD SPED Y-G3.9R3I, COMPACTED ^ � TQ 95I. OF MW(iMLIM DENS Ty "BANK RUNca GRAVEL FOR TRENCH BACKFILL" PER NSDOT STD SPEC S-03 1 %4w "^�..-_� BENCH AS NEEDED FOR SHORING SYSTEM WHEN DEPTH IS 4' OR GREATER PIPE PIPE ZONE BEDDING AND BACKFILL i PER STD PLANS 220M AND 220. 10 ISEE MOTE 1 U NPAVED AREAS + PAVED AREAS NOTES: 1. SEE WSDOTARPWA STANDARD SPECIFICATIONS SECTION 2-0B,4 FOR MEASUREMENT OF TRENCH WIDTH 2. EXCAVATIONS OVER 4' DEEP SHALL COMPLY WITH THE SAFETY STANDARD DESCRIBED IN CHAPTER 295.155 PARS' N OF THE WAG 3. MAXIMUM BAWILL DEPTH ASO M_ PIPE SHALL NOT BE EICCEMEO. AS DETERMINED W PIPE MANUFACTURER. 4 IN PAVED AREAS, IF PIPE HAS LESSTHAN X OF COVER, U5E "CRUSHED SURFACING TOP COURSED FOR THE ENTIRE BACKFILL DEPTH ABOVE PIPE ZONE. 5 SEE CONNSTRUCT10N PLANS FOR SPEOJFIC PROJECT REQUIREMENTS UNLESS OTH{RWISE NDTED, DRAWING 6 NOT TO SCAB: [IFS; STD. PLAN - 220.20 PUBLIC WORKS ° DEPARTMENT TYPICAL TRENCH AND BACKFILL GAZ 9f2812018 1 RATE TRENCH SECTION NOT TO SCALE 11 J R=430703 TACOMA • SEATTLE - SPOKANE • TRI-CITIES 2215 North 30th Street Suite 300 Tacoma WA 98403 253.383.2422 TEL 253.383.2572 FAX www.ahbl.com WEB Project Title: TALBOT HILL ELEMENTARY SCHOOL Client: RENTON SCHOOL DISTRICT ANDREW HOLLENBACK 300 SOUTHWEST 7TH STREET RENTON, WA 98057 Project No. 2230870.10 Issue Set & Date: PERMIT SET JULY 9, 2024 wAOlk SgI�L,� ter_ t�rr ��`sSjONAL ��G 7/9/2024 NOTICE ALTERATION OF THIS DOCUMENT SHALL IWALVATE THE PROFESSIONAL SEAL AND SIGNATURE PUBLICATION OF THIS DODNEIIT DOES NOT DEIMIE FROM RESERVED OWIRSHP RIGHTS N IT. THIS DODMNT IS FOR USE ONLY FOR THE PRQECT DEIITIRED N THE TITLE BLOCK AND IS NOT TO BE USED FOR REPAR, REMODEL OR ADDITION TO THAT PROJECT OR FOR ANY OTHER PRUM. A Revisions: Sheet Title: STORMWATER DRAINAGE NOTES & DETAILS Designed by: Drawn by: Checked by: JAD JAD DCN Sheet No. C2 03 of 05 Sheets DEVELOPMENT ENGINEERING TALBOT HILL ELEMENTARY SCHOOL A PORTION OF THE NE 1/4 OF THE NE 1/4 OF SEC. 30, TWNm 23 N., RGEm 05 E. W.M. CITY OF RENTON, KING COUNTY, WASHINGTON. GRASS SEED, SEE SPECIFICATIONS ROOT ZONE SAND MIX, SEE SPECIFICATIONS BASE SAND MIX, SEE c) SPECIFICATIONS i TRENCH LIMITS z z v 0 PEA GRAVEL BACKFILL Zi °moo "° ° FIRM TRENCH SIDES WITH NO \� oo o o \\\\\/\\\ LOOSE MATERIAL ON BOTTOM R /\ OF TRENCH GEOTEXTILE FABRIC 4" PVC UNDERDRAIN PIPE PEA GRAVEL UNDER PIPE SUBGRADE 4" PERFORATED UNDERDRAIN NOT TO SCALE 0 Know what's below. call before you dig. FINISH GRADE 30% VOID RATIO OF ® %.. ° 4p� ° Sa PEA GRAVEL •4 0 °° o sn4 0 ., o a4 0 °, o u4 0 °, o 0 8 N-12 PERFORATED0 0, v00°°�0 COLLECTOR DRAIN AS PER PLAN ,.�, icy °n .. Lp= g, � •b�B��°a EX�=, e COO• .. UU'"' ° �. i7' c�j• &`°°°s®°° GEOTEXTILE�0 °� p�0 0 °� FABRIC °, °, T::.:�s 1::.,8a °q-�':.,&� 8°':°.8$ % 24" M I N 8" COLLECTOR DRAIN NOT TO SCALE 75 STORMTECH MC-7200 CHAMBERS 200.32 MAXIMUM ALLOWABLE GRADE (TOP OF PAVEMENT/UNPAVED) 14 STORMTECH MC-7200 END CAPS 195.82 MINIMUM ALLOWABLE GRADE (UNPAVED WITH TRAFFIC) 12 STONE ABOVE (in) 195.32 MINIMUM ALLOWABLE GRADE (UNPAVED NO TRAFFIC) 12 STONE BELOW (in) 195.32 MINIMUM ALLOWABLE GRADE (BASE OF FLEXIBLE PAVEMENT) 40 % STONE VOID 195.32 MINIMUM ALLOWABLE GRADE (TOP OF RIGID PAVEMENT) 5,461 SYSTEM AREA (ftz) 194.32 TOP OF STONE 328 SYSTEM PERIMETER (ft) 193.32 TOP OF MC-7200 CHAMBER 20,665 MINIMUM INSTALLED STORAGE (C9 191.29 12" TOP MANIFOLD INVERT 188.51 24" ISOLATOR ROW PLUS CONNECTION INVERT 188.45 12" BOTTOM MANIFOLD INVERT 188.32 BOTTOM OF MC-7200 CHAMBER 187.32 UNDERDRAIN INVERT 187.32 BOTTOM OF STONE ISOLATOR ROW PLUS (SEE DETAIL) PLACE MINIMUM 17.50' OF ADSPLUS125 WOVEN GEOTEXTILE OVER BEDDING STONE AND UNDERNEATH CHAMBER FEET FOR SCOUR PROTECTION AT ALL CHAMBER INLET ROWS BED LIMITS PART TYPE PREFABRICATED END CAP PREFABRICATED END CAP PREFABRICATED END CAP FLAMP MANIFOLD MANIFOLD NYLOPLAST (INLET W/ ISO PLUS ROW) CATCH BASIN (5/C3) NYLOF (OUTLET) UNDERDRAIN INSPECTION PORT I�1 116.86 z Q J 0- Ir- z N W FINISH GRADE PEA GRAVEL BACKFILL UNDERDRAIN PIPE ALT. CONNECTION WHERE INVERT ELEVATIONS ALLOWS. 90 DEG. ELL. W/ 90 DEG. REDUCING SNAP TEE. PERFORATED COLLECTOR DRAIN PIPE, ELEVATION PER FIELD DRAINAGE PLAN 90 DEG. REDUCING SNAP TEE OR 45 DEG. SNAP Y AND REDUCING COUPLING AS REQUIRED (NO 5'-0" � SADDLE TEES). 2" DEPTH MIN. PEA GRAVEL BENEATH PIPE (TYP) GEOTEXTILE FABRIC COLLECTOR DRAIN CONNECTION NOT TO SCALE 'INVERT ABOVE BASE OF CHAMBER w DESCRIPTION INVERT'MAX FLOW A OU A 12" BOTTOM PARTIAL CUT END CAP, PART#: MC72001EPP12B / TYP OF ALL 12" BOTTOM 1.55" CONNECTIONS z W < C)D3 2 o w o B 12" TOP PARTIAL CUT END CAP, PART#: MC72001EPP12T / TYP OF ALL 12" TOP CONNECTIONS 35.69" 24" BOTTOM PARTIAL CUT END CAP, PART#: MC72001EPP24B / TYP OF ALL 24" BOTTOM C CONNECTIONS AND ISOLATOR PLUS ROWS 2 26" J =) LLI J Q Q LLI J 2 z z ?: 0 U _ U o o D INSTALL FLAMP ON 24" ACCESS PIPE / PART#: MCFLAMP E 12" x 12" BOTTOM MANIFOLD, ADS N-12 1.55" F 12" x 12" TOP MANIFOLD, ADS N-12 35.69" G 30" DIAMETER (24.00" SUMP MIN) 7.5 CFS IN = (U o 11 It ce v o rn :� w zz_ LASTH 30" DIAMETER DESIGN BY ENGINEER PER PLAN ( ) 6.0 CFS OUT O m J Q N N Ln O co � w o W I 6" ADS N-12 DUAL WALL PERFORATED HDPE UNDERDRAIN J 4" SEE DETAIL H U w Q o a u>, � a I51.61' w w n z O ww 2 -H F- z w O_ LU �' W ti K w a >Z I �Q zZ Z W O I C) �w U � ww I � a w w� W ¢ I In OU M O ¢ I w w ¢ z I 2E z W w C) U Z. I L) ❑ w w � w� Fo rn a I Of ® o w �U LLO O >� E > O ¢ I y - oa � o rn �~ U L N O) w a w pE 000 ¢ Lq I 000 y 0 o o ow o. N a = zW > LO NO Owl J m Q N W O I6.59' <_� z� LU O r O w J �pC%7 �¢_� oz aW O J O O o z w o V2 ao ww a� zN NOTES m • MANIFOLD SIZE TO BE DETERMINED BY SITE DESIGN ENGINEER. SEE TECHNICAL NOTE 6.32 FOR MANIFOLD SIZING GUIDANCE. LL • DUE TO THE ADAPTATION OF THIS CHAMBER SYSTEM TO SPECIFIC SITE AND DESIGN CONSTRAINTS, IT MAY BE NECESSARY TO CUT AND COUPLE ADDITIONAL PIPE 10 � z r TO STANDARD MANIFOLD COMPONENTS IN THE FIELD. N • THIS CHAMBER SYSTEM WAS DESIGNED WITHOUT SITE -SPECIFIC INFORMATION ON SOIL CONDITIONS OR BEARING CAPACITY. THE SITE DESIGN ENGINEER IS o 0 RESPONSIBLE FOR DETERMINING THE SUITABILITY OF THE SOIL AND PROVIDING THE BEARING CAPACITY OF THE INSITU SOILS. THE BASE STONE DEPTH MAY BE yLL = W INCREASED OR DECREASED ONCE THIS INFORMATION IS PROVIDED. • THE SITE DESIGN ENGINEER MUST REVIEW ELEVATIONS AND IF NECESSARY ADJUST GRADING TO ENSURE THE CHAMBER COVER REQUIREMENTS ARE MET. SHEET 2OF6 ADS STORMTECH MC-7200 STORMWATER DRAINAGE DETENTION FACILITY DETAILS NOT TO SCALE .r W-V FLAT FACE GOTHIC o a I- r DIA ---I o>do � a 0 $TOM 0 4- 0000 CIO HY1r8' DA 76772' DIA I2j M'-,6 S$ SOCI(ET WAD CAP 15' OIA 11) OPEN PICKHOLE 1' SCREW (ALLENHEAD) WAMSHAS ON A B' CIA BOLT CIRCLE COVER SECTION CAST {RON FRAME AND PAVED AREA ITYP.} COVER SEE NOTE 3 t�° 1p• EXTEND DESIGN NDIN SER 2' ABOVE CESiGH PGNDING ELEVATION OR PER PLAN FERNCO GASKETED 011IK CAP Ili 54MILRR DESIGN PONDtNG �!: ELEVATION 4. 57TiElUAgED COBBLES CLASS �• - PER W5DO7 �03.171$y ASPHALTS' 5EE NOTE 1 CLFJWOLII RISER. SEE NOTE +•COMPACTED SAND OR GRAVEL BACKFILL FOR DRAINS PER WSDOT 8-03.12f41 -1-1I, T CLEANOUT RISER. rT1 SOIL TK3HT 45' BEND SEE NOTE 7 l AT SOIL TIGHT GHT I COUPLER 1T UHDERDRAIN, FDOTINC IT DRAIN G9LLEGTdi, OR ROOF DRAIN COLLECTOR PIPE. SEE NOTE T - CLEANOUT RISER LOCATED WITHIN BIORE'TENTION PONDING AREA •"-.- , liiliiill TOOVERFLOW STRUCTURE OR STORM MAIN MECHANICAL PLUG OR CONTINUED CONNECTION TYPICAL CLEANOUT CONFIGURAT1011 NOTES; 1. DIAMETER TO BE &INCHES MINr"UM PRIVATE. 8-INCHES MINIMUM PUBLIC. UNDERORAIN PIPE PER STD PLAN 262.1D 2. CLEANOUT RISER SHALL BE SAME MATERIAL AS CONNECTED UNDERDRAIN. FOOTING DRAIN COLLECTOR DR ROOF BRAIN COLLECTOR PIPE 3 FRAME A20 COVER SHALL BE EA PRODUCTS 3f 7U11PT AND M75APT OR APPROVED EQUAL COVER TA BE LOCKING WITH ALLEN MEAD BOLT, MARKED "5TORM" OR 'iIRAIN' A. FOR CLEANOUTS FULLY OR PARTLALLY WITHIN UNPAVED AREAS OUTSIDE OF BIDRETENTION FUNDING AREA, POUR S' THICK 9'I17 SQUARE CONCRETE COLLAR AROUND FRAME. CONCRETE COLLAR SHALL HAVE A MINIMUM COMPRESSIVE STRENGTH OF 3.OW PSI. GENERAL NOTES: 1 . CLEANOUTS FOR UNDERORAIN. FDOTING DRAIN COLLECTOR, AND ROOF DRAIN COLLECTOR PIPES SMALL BE INSTALLED AT A MINIMUM OF EVERY 100 FEET. AT EVERY W DEGREE OR SECOND 45 DEGREE BEND, AT THE END OF EVERY COLLECTOR PIPE AND AT EACH END OF AN UNDERDRMN PIPE NOT CONNECTED TO AN OVERFLOW STRUCTURE CLEANOUT5 SHALL SE INSTALLED TO ALLOW FOR MAINTENANCE ACCESS TO ALL PEES_ 2- ALL FITTINGS SHALL BE SOIL TIGHT. 3. CLEANOUT RISER SHALL BE LOCATED OUTSIDE OF MORETENTION PONOING WHERE POSSIBLE 4. CLEANOUTS SHALL NOT BE LOCATED WITHIN THE STREET TRAVEL LANI=, UNLESS OTHERWISE APPROVED BY THE CITY. UNLf55 OTHERWISE NCTE°, DRAWING IS NOT TO SCALE { NTS I STD. PLAN - 226,00 PUBLIC WORKS °6' .� STORM SYSTEM CLEANOUT s/13/20 ❑EPARTMENT artin Pastucha V4337 DATE COLLECTOR DRAIN CLEAN OUT NOT TO SCALE 7 MIN. CLEARANCE TO ANY PORTION OF FLOW RESTRICTOR TEE INCLUDING ELBOWS , REMOVABLE f►� jl I O FLANGE COUPLING OR FLANGE 3'HAIIN. A ELBOW RESTRICTIOIK SEEDETAILANDNDTE 10 j J ANGLE AS NECESSARY, / SEE NOTE B MIN. ' MIN, ^-� S" MAX. PLATE WELDED TO ELBOW WITH PLAN VIEW IE4I; ICE AS SPECIFIED, SEE NOTE 3 ELBOW RESTRICTOR DETAIL ADDITIONAL LADDER RUNGS (IN SET5I TO ALLOW ACCESS TO TANKS OR VAULT$ WHEN CATCH I5 HUED WITH WATER FL EVATI ON PER PLANS 72" MIN UNDER r FRAME d SOLID COVER MARKED 'DRlUN" WITH PAVEMENT 1 LOCKING BOLTS PER STD PLANS 2N.40 AND 204.50 !! RIM ELEV. = IW.61 ERTICAL BAR GRATE FOR SECONDARY INLET 6 MINOP -OF RISER 1 DESIGN WATER ELBOW RESTRICTOR,URFACE ELEV- = 195.40 SEE DETAIL AND NOTE IDRANDHOLDS. STEPS. OR LADDER PIPE SUPPORTS, SEE NO 1 5 x rD 5EE NOTE 13 ITYP.N7x OUTLET PIPE. SINLET PIPE 12, PVC amn IE 188.44 NOTES I A 6INVERT ANDSHEAR GATE WITH CONTROL ROD FOR ELEVATION PER PLANSC. (ROD T At,WITH REQUCOVE RED FORCILEVERTICALA L FOR VERTICAL ALIGNMENT WITH COVER] NT 72' SECTION OF PIPE ATTACHED BY 1 PER S7p PLAN 237.3E GA.SKETED SAID TO ALLOW REMOVAL c� 2' 12 MIN WELDED ROLA ORIFICE 61AASESTRECTSPECIFIEDRPTE. 5EE NWITHOTE 10 ELEV = 186.40 ORIFICE DIA = 0.559• SECTION A NOTES: 1 USE A MINIMUM OF A 64" DABAMFI TYPE 2 CATCH BASIN. 2. OUTLET CAPACITY: 100•YEAR DEVELOPED PEAK FLOW. 3. METAL PARTS PREFERRED TO BE STAINLESS STEEL, ALUMIN2ED STEEL, OR ALUMINUM. ALL OTHER STEEL PARTS MUST BE GALVANIZE D VJHTH TREATMENTS 1, 2 OR 5. i FRAME AND LADDER OR STEA$ OFFSET SD: A CLEANOUT GATE 15 VISIBLE FROM TOP. B CLIMB -DOWN SPACE IS CLEAR Of RISER AND CLEANOUT GATE. C FRAME IS CLEAR OF CURB. S. IF METAL OUTLET PIPE CONNECTS TO CEMENT CONCRETE PIPE: OUTLET PIPE TO HAVE SMOOTH O.D. EQUAL TO CONCRETE PIPE 10. LESS 114'. 6. PROVIDE AT LEAST ONE 3' X .080 GAGE SUPPORT BRACKET ANCHORED TO CONCRETE WALL IMA%IMUM T-O' VERTICAL SPACINGI 1. LOCATE ELBOW RESTRICTORISi AS NECESSARY TO PROVIDE MINIMUM CLEARANCE AS SH IC WN. B. LOCATE ADDITIONAL LADDER RUNGS 04 STRUCTURES USED ASACCESS TD TANKS AND VAULTS TO ALLOW ACCESS VMFN CATCH BASIN 19 KILLED WITH WATER 9. WHEN CONNECTING TD A NEW PIPE, U SE A FLEX{BLE CONRECTOR IKOR-N-5EAL BOOT WITH C(5RRUGATED PIPE A°APTER OR APPROVED EULIALI. WHEN CONNECTING TO AN EXISTING PIPE, USE A FABRICATED SAND COLLAR OF THE SAME MATERIAL AS THE CONNECTING PIPE. 10. IF TEE SECTION IS USED ONLY FOR SPILL CONTROL T4[EN ELBOW RE STRI CTORS AND RE STRICTOR PLATES WITH ORIFICES ARE NOT REM IRFD. UNLESS OTHER WISE NOTES, DRAWING IS NOT TO SCALE {FMI STD. PLAN - 237.00 . �� PUBLIC WORKS FLOW CONTROL STRUCTURE - 6y UAL DEPARTMENT UR RESTRIC€OR TEE Martin Pastucha 8/i3�70 JI Ir 786WOD DATE CONTROL STRUCTURE NOT TO SCALE 0 CD LO N O 0 N 14, � J C C R=430704 TACOMA • SEATTLE • SPOKANE • TRI-CITIES 2215 North 30th Street, Suite 300 Tacoma, WA 98403 253.383.2422 TEL 253.383.2572 FAX www.ahbl.com WEB Project Title: TALBOT HILL ELEMENTARY SCHOOL Client: RENTON SCHOOL DISTRICT ANDREW HOLLENBACK 300 SOUTHWEST 7TH STREET RENTON, WA 98057 Project No. 2230870.10 Issue Set & Date: PERMIT SET JULY 9, 2024 7/9/2024 NOTICE ALTERATION OF THIS DOME NT SHALL INVALDATE THE PROFESSIONAL SEAL AND SIGNATURE PUBLICATION OF THIS DOCUMENT DOES NOT DEROGATE FROM RESERVED OII EiSIf MRS N IT. THIS DOCUMENT IS FOR USE ONLY FOR THE PROM DARED N THE TITLE BLOC( AND IS NOT TO BE USED FOR REPAIR, REMODEL OR ADDITION TO THAT PROAM OR FOR ANY OTHER PROJ7. A Revisions: Sheet Title: STORMWATER DRAINAGE DETAILS Designed by: Drawn by- Checked by: JAD JAD DCN Sheet No- 04 of 05 Sheets ti O M W FM DEVELOPMENT ENGINEERING Q TALBOT HILL ELEMENTARY SCHOOL Ito A PORTION OF THE NE 1/4 OF THE NE 1/4 OF SEC. 30, TWNm 23 N.,LO RGEm 05 E. W.M. CITY OF RENTON, KING COUNTY, WASHINGTON. � N i.: 11AW. Advanced Drainage Systems, Inc. MC-7200 STORMTECH CHAMBER SPECIFICATIONS 1. CHAMBERS SHALL BE STORMTECH MC-7200. CHAMBERS SHALL BE ARCH -SHAPED AND SHALL BE MANUFACTURED FROM VIRGIN, IMPACT -MODIFIED POLYPROPYLENE COPOLYMERS. 3, CHAMBERS SHALL MEET THE REQUIREMENTS OF ASTM F2418.16a,'STANDARD SPECIFICATION FOR POLYPROPYLENE (PP) CORRUGATED WALL STORMWATER COLLECTION CHAMBERS -CHAMBER CLASSIFICATION 60001. 4. CHAMBER ROWS SHALL PROVIDE CONTINUOUS, UNOBSTRUCTED INTERNAL SPACE WITH NO INTERNAL SUPPORTS THAT WOULD IMPEDE FLOW OR LIMIT ACCESS FOR INSPECTION. 5. THE STRUCTURAL DESIGN OF THE CHAMBERS, THE STRUCTURAL BACKFILL, AND THE INSTALLATION REQUIREMENTS SHALL ENSURE THAT THE LOAD FACTORS SPECIFIED IN THE AASHTO LRFD BRIDGE DESIGN SPECIFICATIONS, SECTION 12.12, ARE MET FOR: 1) LONG -DURATION DEAD LOADS AND 2) SHCRT-DURATION LIVE LOADS. BASED ON THE AASHTO DESIGN TRACK WITH CONSIDERATION FOR IMPACT AND MULTIPLE VEHICLE PRESENCES. 6. CHAMBERS SHALL BE DESIGNED, TESTED AND ALLOWABLE LOAD CONFIGURATIONS DETERMINED IN ACCORDANCE WITH ASTM F2787, *STANDARD PRACTICE FOR STRUCTURAL DESIGN OF THERMOPLASTIC CORRUGATED WALL STORMWATER COLLECTION CHAMBERS'. LOAD CONFIGURATIONS SHALL INCLUDE: 1) INSTANTANEOUS (0 MIN) AASHTO DESIGN TRUCK LIVE LOAD ON MINIMUM COVER 2) MAXIMUM PERMANENT (75-YR) COVER LOAD AND 3) ALLOWABLE COVER WITH PARKED (1-WEEK) AASHTO DESIGN TRUCK. 7. REQUIREMENTS FOR HANDLING AND INSTALLATION: • TO MAINTAIN THE WIDTH OF CHAMBERS DURING SHIPPING AND HANDLING, CHAMBERS SHALL HAVE INTEGRAL, INTERLOCKING STACKING LUGS. • TO ENSURE A SECURE JOINT DURING INSTALLATION AND BACKFILL, THE HEIGHT OF THE CHAMBER JOINT SHALL NOT BE LESS THAN 3. • TO ENSURE THE it OF THE ARCH SHAPE DURING INSTALLATION, a) THE ARCH STIFFNESS CONSTANT SHALL BE GREATER THAN OR EQUAL TO 450 LBS4 WIN. THE ABC IS DEFINED IN SECTION 6.2.8 OF ASTM F24IS AND b) TO RESIST CHAMBER DEFORMATION DURING INSTALLATION AT ELEVATED TEMPERATURES (ABOVE 73' F 123' C), CHAMBERS SHALL BE PRODUCED FROM REFLECTIVE GOLD OR YELLOW COLORS. 8. ONLY CHAMBERS THAT ARE APPROVED BY THE SITE DESIGN ENGINEER WILL BE ALLOWED. UPON REQUEST BY THE SITE DESIGN ENGINEER OR OWNER, THE CHAMBER MANUFACTURER SHALL SUBMIT A STRUCTURAL EVALUATION FOR APPROVAL BEFORE DELIVERING CHAMBERS TO THE PROJECT SITE AS FOLLOWS: • THE STRUCTURAL EVALUATION SHALL BE SEALED BY A REGISTERED PROFESSIONAL ENGINEER. • THE STRUCTURAL EVALUATION SHALL DEMONSTRATE THAT THE SAFETY FACTORS ARE GREATER THAN OR EQUAL TO 1.95 FOR DEAD LOAD AND 1.75 FOR LIVE LOAD, THE MINIMUM REQUIRED BY ASTM F2787 AND BY SECTIONS 3 AND 12.12 OF THE AASHTO LRFD BRIDGE DESIGN SPECIFICATIONS FOR THERMOPLASTIC PIPE. • THE TEST DERIVED CREEP MODULUS AS SPECIFIED IN ASTM F2418 SHALL BE USED FOR PERMANENT DEAD LOAD DESIGN EXCEPT THAT IT SHALL BE THE 75-YEAR MODULUS USED FOR DESIGN. 9. CHAMBERS AND END CAPS SHALL BE PRODUCED AT AN ISO 9001 CERTIFIED MANUFACTURING FACILITY. COVER PIPE CONNECTION TO END CAP WITH ADS GEOSYNTHETICS 601T NON -WOVEN GEOTEXTILE STORMTECH HIGHLY RECOMMENDS 1 - FLEXSTORM INSERTS IN ANY UPSTREAM STRUCTURES WITH OPEN GRATES ,1 ELEVATED BYPASS MANIFOLD SiteASSIST' ar FOR STORMTECH INSTRUCTIONS, DOWNLOAD THE a INSTALLATION APP o. IMPORTANT - NOTES FOR THE BIDDING AND INSTALLATION OF MC-7200 CHAMBER SYSTEM 1, STORMTECH MC-7200 CHAMBERS SHALL NOT BE INSTALLED UNTIL THE MANUFACTURER'S REPRESENTATIVE HAS COMPLETED A PRE -CONSTRUCTION MEETING WITH THE INSTALLERS. 2. STORMTECH MC-7200 CHAMBERS SHALL BE INSTALLED IN ACCORDANCE WITH THE "STORMTECH MC-7200 CONSTRUCTION GUIDE". 3. CHAMBERS ARE NOT TO BE BACKFILLED WITH A DOZER OR EXCAVATOR SITUATED OVER THE CHAMBERS. STORMTECH RECOMMENDS 3 BACKFILL METHODS: STONESHOOTER LOCATED OFF THE CHAMBER BED. BACKFILL AS ROWS ARE BUILT USING AN EXCAVATOR ON THE FOUNDATION STONE OR SUBGRADE. • BACKFILL FROM OUTSIDE THE EXCAVATION USING A LONG BOOM HOE OR EXCAVATOR. 4. THE FOUNDATION STONE SHALL BE LEVELED AND COMPACTED PRIOR TO PLACING CHAMBERS, 5. JOINTS BETWEEN CHAMBERS SHALL BE PROPERLY SEATED PRIOR TO PLACING STONE. 6. MAINTAIN MINIMUM -9'(230 mm) SPACING BETWEEN THE CHAMBER ROWS. 7, INLET AND OUTLET MANIFOLDS MUST BE INSERTED A MINIMUM OF 12` (300 mm) INTO CHAMBER END CAPS. 8, EMBEDMENT STONE SURROUNDING CHAMBERS MUST BE A CLEAN, CRUSHED, ANGULAR STONE MEETING THE AASHTO M43 DESIGNATION OF #3 OR #4. 9. STONE SHALL BE BROUGHT UP EVENLY AROUND CHAMBERS SO AS NOT TO DISTORT THE CHAMBER SHAPE. STONE DEPTHS SHOULD NEVER DIFFER BY MORE THAN 12" (3DO mm) BETWEEN ADJACENT CHAMBER ROWS. 10. STONE MUST BE PLACED ON THE TOP CENTER OF THE CHAMBER TO ANCHOR THE CHAMBERS IN PLACE AND PRESERVE ROW SPACING. 11. THE CONTRACTOR MUST REPORT ANY DISCREPANCIES WITH CHAMBER FOUNDATION MATERIAL BEARING CAPACITIES TO THE SITE DESIGN ENGINEER. 12. ADS RECOMMENDS THE USE OF "FLEXSTORM CATCH IT" INSERTS DURING CONSTRUCTION FOR ALL INLETS TO PROTECT THE SUBSURFACE STORMWATER MANAGEMENT SYSTEM FROM CONSTRUCTION SITE RUNOFF. NOTES FOR CONSTRUCTION EQUIPMENT 1. STORMTECH MC-7200 CHAMBERS SHALL BE INSTALLED IN ACCORDANCE WITH THE'STORMTECH MC-7200 CONSTRUCTION GUIDE'. 2. THE USE OF EQUIPMENT OVER MC-720D CHAMBERS IS LIMITED: NO EQUIPMENT IS ALLOWED ON BARE CHAMBERS. • NO RUBBER TIRED LOADER, DUMP TRUCK. OR EXCAVATORS ARE ALLOWED UNTIL PROPER FILL DEPTHS ARE REACHED IN ACCORDANCE WITH THE "STORMTECH MC-7200 CONSTRUCTION GUIDE'. • WEIGHT LIMITS FOR CONSTRUCTION EQUIPMENT CAN BE FOUND IN THE'STORMTECH MC-7200 CONSTRUCTION GUIDE", 3. FULL 36" (900 mm) OF STABILIZED COVER MATERIALS OVER THE CHAMBERS IS REQUIRED FOR DUMP TRUCK TRAVEL OR DUMPING. USE OF A DOZER TO PUSH EMBEDMENT STONE BETWEEN THE ROWS OF CHAMBERS MAY CAUSE DAMAGE TO CHAMBERS AND IS NOT AN ACCEPTABLE BACKFILL METHOD. ANY CHAMBERS DAMAGED BY USING THE "DUMP AND PUSH" METHOD ARE NOT COVERED UNDER THE STORMTECH STANDARD WARRANTY. CONTACT STORMTECH AT 1-888-892-2694 WITH ANY QUESTIONS ON INSTALLATION REQUIREMENTS OR WEIGHT LIMITS FOR CONSTRUCTION EQUIPMENT. INSTALL FLAMP ON 24' (600 mm) ACCESS PIPE PART #: MCFLAMP r MC-7200 CHAMBER OPTIONAL INSPECTION PORT MC-7200 END CAP ------- ---- --- SUMP DEPTH TED BY CATCH BASIN SITE DESIGN ENGINEER OR MANHOLE (24' (600 mm) MIN RECOMMENDED) 24' (600 mm) HOPE ACCESS PIPE REQUIRED ONE LAYER OF ADSPLILS125 WOVEN GEOTEXTILE BETWEEN USE FACTORY PARTIAL CUT END CAP PART #: FOUNDATION STONE AND CHAMBERS I I 248 OR MC72001EPP248W 10.3' (3.1 m MIN WIDE CONTINUOUS FABRIC WITHOUT SEAMS MC72001EPP) 3 MC-7200 ISOLATOR ROW PLUS DETAIL 12" (300 mm) MIN WIDTH - I_ NYLOPLAST 8" LOCKING SOLID COVER AND FRAME 8' (200 mm) MIN THICKNESS OF ASPHALT CONCRETE COLLAR! ASPHALT OVERRAN OVERLAY AND CONCRETE COLLAR - NOT REQUIRED FOR GREENSPACE OR INSPECTION & MAINTENANCE NON -TRAFFIC APPLICATIONS STEP 1) INSPECT ISOLATOR ROW PLUS FOR SEDIMENT _ A. INSPECTION PORTS (IF PRESENT) _ - Al. REMOVE/OPEN LID ON NYLOPLAST INLINE DRAIN _ 8" NYLOPLAST UNIVERSAL DRAIN BODY A,2. REMOVE AND CLEAN FLEXSTORM FILTER IF INSTALLED (PART# 2708AG41PKIT) OR TRAFFIC RATED A.3. USING A FLASHLIGHT AND STADIA ROD, MEASURE DEPTH OF SEDIMENT AND RECORD ON MAINTENANCE LOG ASPHALT OVERLAY FOR J BOX W7SOLID LOCKING COVER A.4. LOWER A CAMERA INTO ISOLATOR ROW PLUS FOR VISUAL INSPECTION OF SEDIMENT LEVELS (OPTIONAL) TRAFFIC APPLICATIONS A.S. IF SEDIMENT IS AT, OR ABOVE, 3' (80 mm) PROCEED TO STEP 2. IF NOT. PROCEED TO STEP 3. 4" 1100 mm) SDR 35 PIPE B. ALL ISOLATOR PLUS ROWS CONCRETE COLLAR J -, _ _ 8.1. REMOVE COVER FROM STRUCTURE AT UPSTREAM END OF ISOLATOR ROW PLUS 0.2. USING A FLASHLIGHT. INSPECT DOWN THE ISOLATOR ROW PLUS THROUGH OUTLET PIPE STORMTECH CHAMBER 1) MIRRORS ON POLES OR CAMERAS MAYBE USED TO AVOID A CONFINED SPACE ENTRY ;1) FOLLOW OSHA REGULATIONS FOR CONFINED SPACE ENTRY IF ENTERING MANHOLE 4' (100 mm) INSERTA TEE B.3. IF SEDIMENT IS AT, OR ABOVE, 3" (80 ..)PROCEED TO STEP 2. IF NOT, PROCEED TO STEP 3. TO BE CENTERED ON CORRUGATION VALLEY STEP 2) CLEAN OUT ISOLATOR ROW PLUS USING THE JETVAC PROCESS A. A FIXED CULVERT CLEANING NOZZLE WITH REAR FACING SPREAD OF 45' (1.1 m) OR MORE IS PREFERRED B. APPLY MULTIPLE PASSES OF JENAC UNTIL BACKFLUSH WATER IS CLEAN C. VACUUM STRUCTURE SUMP AS REQUIRED STEP 3) REPLACE ALL COVERS, GRATES, FILTERS, AND LIDS; RECORD OBSERVATIONS AND ACTIONS - STEP 4) INSPECT AND CLEAN BASINS AND MANHOLES UPSTREAM OF THE STORMTECH SYSTEM. NOTE: INSPECTION PORTS MAY BE CONNECTED THROUGH ANY CHAMBER CORRUGATION VALLEY. NOTES 1. INSPECT EVERY 6 MONTHS DURING THE FIRST YEAR OF OPERATION. ADJUST THE INSPECTION INTERVAL BASED ON PREVIOUS OBSERVATIONS OF SEDIMENT ACCUMULATION AND HIGH WATER ELEVATIONS. 2. CONDUCT JETTING AND VACTORING ANNUALLY OR WHEN INSPECTION SHOWS THAT MAINTENANCE IS NECESSARY. 4 4" PVC INSPECTION PORT DETAIL (MC SERIES CHAMBER) STORMTECH STORMTECH CHAMBER OUTLET MANIFOLD FOUNDATION STONE BENEATH CHAMBERS ADS GEOSYNTHETICS 801T J NON -WOVEN GEOTEXTILE JJ SECTION A -A DUAL WALL PERFORATED HDPE STORMTECH -- UNDERDRAIN END CAP r' - FOUNDATION STONE A BENEATH CHAMBERS T ADS GEOSYNTHETICS 601T A NON -WOVEN GEOTEXTILE NUMBER AND SIZE OF UNDERDRAINS PER SITE DESIGN ENGINEER 4(100 mm) TYP FOR SC-310 & SC-160LP SYSTEMS SECTION B-B 6' (150 mm) TYP FOR SC-740, SC-800, DC-780, MC-3500, MCI500 & MC-7200 SYSTEMS 5 UNDERDRAIN DETAIL T STORMTECH END CAP 12' (300 mm) MIN INSERTION MANIFOLD STUB MANIFOLD HEADER 2 300 mm MIN SEPARATION 12' (300 mm) MIN SEPARATION VALLEY CREST STIFFENING RIB WEB (,jl LOWER JOINTRUGATION CORRUU PER GATION Q p CORRUGATION CORRUGATION W U � 79 I- Q (2010 m) 834" CREST INSTALLED (2120 mm) STIFFENING N - W RIB O Z ~ W O �_ H =a In U O o K LU Z > In FOOT LU ­30 K a BUILD ROW IN THIS DIRECTION O a LU Q V) Z 0 0 <Z 1- W cC pz 60.0" 32.8' G Z UO-1 (1524 (833-) mm) 61.0 J Ow (1549mm) INSTALLED W F Uj W Z 2 Z F 100.0" (2540 mml 9DAr (2286 mm) > I jJ > W, F NOMINAL CHAMBER SPECIFICATIONS QUJ �W SIZE (W X H X INSTALLED LENGTH) 100.0`X60,0-X79.1` (2540 mm X 1524 mm X 2010 mm) Q ,r WZ CHAMBER STORAGE 175.9 CUBIC FEET (4.98 m') L"� -� W MINIMUM INSTALLED STORAGE- 267.3 CUBIC FEET (7.66 m') a WEIGHT (NOMINAL) 2051bs. (92.9 kg) 7 DU NOMINAL END CAP SPECIFICATIONS 38.0" Z 00 SIZE (W X H X INSTALLED LENGTH) 90.0" X 61.0" X 32.8' (2286 mm X 1549 mm X 833 mm) (965 mml I-" O W END CAP STORAGE 315 CUBIC FEET (1.12 m') Q = MINIMUM INSTALLED STORAGE' 115.3 CUBIC FEET (3.26 m') K WEIGHT JNOMINAL) 901bs. (40.8 kg) Z 'ASSUMES 12" (305 mm) STONE ABOVE, 9- (229 mm) STONE FOUNDATION AND BETWEEN CHAMBERS, Z W 12' (305 mm) STONE PERIMETER IN FRONT OF END CAPS AND 40% STONE POROSITY. w IA PARTIAL CUT HOLES AT BOTTOM OF END CAP FOR PART NUMBERS ENDING WITH'8' ~ Z PARTIAL CUTPpp_FpjrATpn S ENDING WITH HOLES AT TOP OF END CAP FOR PART NUMBERQ wWITH Z ip K F e > U T Z y W00 °U W a0 W K J �WU Q Inaw Q J � CUSTOM PREFABRICATED INVERTS ¢ F aL. ARE AVAILABLE UPON REQUEST. = W INVENTORIED MANIFOLDS INCLUDE O W K IS = 12-24- (300-600 mm) SIZE ON SIZE O W AND 15-a' (375-1200 mm) O 0 Z EC�= W O CENTRIC MANIFOLDS. CUSTOM LL N E D CA CUT I THE ON THE MC -NOT A Q W 3 J END CAP CUT IN THE FIELD ARE NOT 1 N RECOMMENDED FOR PIPE SIZES I li K Q GREATER THAN 10" (250 mm). THE U EL w a INVERT LOCATION IN COLUMN'S' N C W ARE THE HIGHEST POSSIBLE FOR H:J U THE PIPE SIZE. Q W = Q Z 0"� 0 LJ 6 MC -SERIES END CAP INSERTION DETAIL 12 MC-7200 TECHNICAL SPECIFICATIONS W W z Leo ACCEPTABLE FILL MATERIALS: STORMTECH MC-7200 CHAMBER SYSTEMS WFn Wp'O xWa NOTE: MANIFOLD STUB MUST BE LAID HORIZONTAL FOR A PROPER FIT IN END CAP OPENING. MANIFOLD HEADER MANIFOLD STUB PART # STUB B C MC72001EPP06T 6-(150 42.54'(1081 -) - -MC72001EP 0,86'422 -) MC72001EPP08 g(200 mm) - (1029 - 1.01' (26 mm) MC72001EPP088 MC72001EPPIOT 10' (250 mm) 38.37' (975 mm) - - 1.33' (34 mm) MC72001EPP10B MC72001EPP12T 12' (300 mm) 35.69' (907 mm) - - 1.55' (39 mm) MC72001EPP728 MC72001EPP15T 15' (375 mm) 32.72' (831 mm) - - 1.70-(43 mml MC72001EPP756 MC72001EPP787 29.36`(746 mm) - MC72001EPP78TW 18"(450 mm) MC72001EPP788 - 1.97' (50 mm) MC72001EPPI88W MC72001EPP24T 23.05' S85 mm ( 1 - MC72001EPP24TW 24'(B00 mm) MC72001EPP248 - 226' (57 mm) MC72001EPP2/BW MC72001EPP306W 30'(750 mm) - 2.95`(75 mm) MC72001EPP36OW 36" (900 mm) - 3,25` (83 mm) MC7200IEPP426W 42y7050 mm) 3.55' (90 mm) AASHTO MATERIAL MATERIAL LOCATION DESCRIPTION COMPACTION / DENSITY REQUIREMENT CLASSIFICATIONS FINAL FILL: FILL MATERIAL FOR LAYER D' STARTS FROM THE PREPARE PER SITE DESIGN ENGINEER'S PLANS. PAVED D TOP OF THE'C' LAVER TO THE BOTTOM OF FLEXIBLE ANY SOILIROCK MATERIALS, NATIVE SOILS, OR PER ENGINEER'S PLANS. NIA INSTALLATIONS MAY HAVE STRINGENT MATERIAL AND PAVEMENT OR UNPAVED FINISHED GRADE ABOVE. NOTE THAT CHECK PLANS FOR PAVEMENT SUBGRADE REQUIREMENTS. PREPARATION REQUIREMENTS. PAVEMENT SUBBASE MAY BE PART OF THE D' LAYER AASHTO M145' INITIAL FILL: FILL MATERIAL FOR LAYER'C STARTS FROM THE GRANULAR WELL -GRADED SOILIAGGREGATE MIXTURES, -35% FINES OR A-1, A-2-4, A-3 BEGIN COMPACTIONS AFTER 24" (600 mm) OF MATERIAL OVER TOP OF THE EMBEDMENT STONE ('B' LAVER) TO 24'(600 mm) PROCESSED AGGREGATE. THE CHAMBERS IS REACHED. COMPACT ADDITIONAL LAYERS IN C HE THE CHAMBER NOTE THAT PAVEMENT ABOVE THE TOP OF THE CHA OR l2' (300 mm) MAX LIFTS TO A MIN. 95% PROCTOR DENSITY FOR SUBBASE MAY BE A THE RG' LAYER MOST PAVEMENT SUBBASE MATERIALS CAN BE USED IN LIEU OF THIS LAVER, AASHTO M43' WELL GRADED MATERIAL AND 95% RELATIVE DENSITY FOR PROCESSED AGGREGATE MATERIALS, 3, 357, 4, 467, 5, 56, 57, 6, 67, 68, 7, 78, 8, 89, 9. 10 EMBEDMENT STONE: FILL SURROUNDING THE CHAMBERS AASHTO M43' 8 FROM THE FOUNDATION STONE ('A' LAVER) TO THE C.LAVER CLEAN. CRUSHED, ANGULAR STONE OR RECYCLED CONCRETE' NO COMPACTION REQUIRED. ABOVE. 3. 357.4.A67, 5, 56, 57 A FOUNDATION STONE: FILL BELOW CHAMBERS FROM THE CLEAN. CRUSHED, ANGULAR STONE OR RECYCLED CONCRETE° AASHTO M43' PLATE COMPACTOR ROLL TO ACHIEVE A FLAT SURFACE." SUBGRADE UP TO THE FOOT (BOTTOM) OF THE CHAMBER. 3, 357, 4, 467, 5, 56, 57 r pmJ Z = H U~o W W W Z W = OZ� W 0 i-WH O 0 US W . w cc W 00 IL Z zQ In QW W Z W PLEASE NOTE: o =J W� 1. THE LISTED AASHTO DESIGNATIONS ARE FOR GRADATIONS ONLY. THE STONE MUST ALSO BE CLEAN, CRUSHED. ANGULAR. FOR EXAMPLE, A SPECIFICATION FOR A'4 STONE WOULD STATE "CLEAN, CRUSHED, ANGULAR NO.4 (AASHTO M43) STONE". W O In 5 2. STORMTECH COMPACTION REQUIREMENTS ARE MET FORA' LOCATION MATERIALS WHEN PLACED AND COMPACTED IN 91 (230 mm) (MAX) LIFTS USING TWO FULL COVERAGES WITH A VIBRATORY COMPACTOR. •O 3. WHERE INFILTRATION SURFACES MAY BE COMPROMISED BY COMPACTION FOR STANDARD DESIGN LOAD CONDITIONS A FLAT SURFACE MAY BE ACHIEVED BY RAKING OR DRAGGING WITHOUT COMPACTION EQUIPMENT. FOR SPECIAL LOAD DESIGNS. CONTACT STORMTECH FOR � N W0 Z < COMPACTION REQUIREMENTS. = p _J /. ONCE LAVER'C IS PLACED, ANV SOILIMATERIAL CAN BE PLACED IN LAYER'D' UP TO THE FINISHED GRADE. MOST PAVEMENT SUBBASE SOILS CAN SE USED TO REPLACE THE MATERIAL REQUIREMENTS OF LAYER'C' OR'D' AT THE SITE DESIGN ENGINEER'S DISCRETION. "RECYCLED Q W Q 5. WHERE RECYCLED CONCRETE AGGREGATE IS USED IN LAYERS'N OR'B' THE MATERIAL SHOULD ALSO MEET THE ACCEPTABILITY CRITERIA OUTLINED IN TECHNICAL NOTE 6.20 CONCRETE STRUCTURAL BACKFILL'. d E Z Z O H T_ UO E owlJ toW O ADS GEOSYNTHETICS60ITNON-WOVEN GEOTEXTILE ALL AROUND CLEAN, CRUSHED, ANGULAR STONE IN A 8 B LAVERS PAVEMENT LAYER (DESIGNED $ 1.E R,. W Q W BY SITE DESIGN ENGINEER) 0E VU y H L � W V) iiU WJm PERIMETER STONE D 7.a Isw,r occu 24' (21m) C W o j w W (SEE NOTE 4) r 4l (600 mm) MIN* MAX 12"(300)MIN mm Z Z f O p(n< "THIS J N O LU U)) Z W J EXCAVATION WALL ,! 80- CROSS SECTION DETAIL REPRESENTS m Q � m m (CAN BE SLOPED OR VERTICAL) _ (1524 mm) MINIMUM REQUIREMENTS FOR INSTALLATION, PLEASE SEE THE LAYOUT SHEET(S) FOR Z F Q J U U II PROJECT SPECIFIC REQUIREMENTS. Q = H IL_ O ox< LU W. - I`-i.'=; dill II Ic-III-L II -I- i-I i 1-L-1 I - - - II -Id J-df7d '.. III' III_ DEPTH OF STONE TO BE DETERMINED BY SITE DESIGN ENGINEER 9' (230 mm) MIN = Iq I- Q f U 12" (300 mm) MINGILL�JI MC-7200 SOILS (230 mm) MIN 100' (2540 mm7 12" (300 mm) MIN i'- Q W Ix WSUBGRADE O W END CAP (SEE NOTE 3) J a w X NOTES: 1. CHAMBERS SHALL MEET THE REQUIREMENTS OF ASTM F2418, -STANDARD SPECIFICATION FOR POLYPROPYLENE (PP) CORRUGATED WALL STORMWATER COLLECTION CHAMBERS" CHAMBER CLASSIFICATION 60:101 2. MC-7200 CHAMBERS SHALL BE DESIGNED IN ACCORDANCE WITH ASTM F2787 *STANDARD PRACTICE FOR STRUCTURAL DESIGN OF THERMOPLASTIC CORRUGATED WALL STORMWATER COLLECTION CHAMBERS'. 3. THE SITE DESIGN ENGINEER IS RESPONSIBLE FOR ASSESSING THE BEARING RESISTANCE (ALLOWABLE BEARING CAPACITY) OF THE SUBGRADE SOILS AND THE DEPTH OF FOUNDATION STONE WITH CONSIDERATION FOR THE RANGE OF EXPECTED SOIL MOISTURE CONDITIONS. 4. PERIMETER STONE MUST BE EXTENDED HORIZONTALLY TO THE EXCAVATION WALL FOR BOTH VERTICAL AND SLOPED EXCAVATION WALLS. 5. REQUIREMENTS FOR HANDLING AND INSTALLATION: • TO MAINTAIN THE WIDTH OF CHAMBERS DURING SHIPPING AND HANDLING CHAMBERS SHALL HAVE INTEGRAL INTERLOCKING STACKING LUGS. • TO ENSURE A SECURE JOINT DURING INSTALLATION AND BACKFILL. THE HEIGHT OF THE CHAMBER JOINT SHALL NOT BE LESS THAN 3'. • TO ENSURE THE INTEGRITY OF THE ARCH SHAPE DURING INSTALLATION, a) THE ARCH STIFFNESS CONSTANT AS DEFINED IN SECTION 6.2.8 OF ASTM F2418 SHALL BE GREATER THAN OR EQUAL TO 500 LBSIFTI%. AND b) TO RESIST CHAMBER DEFORMATION DURING INSTALLATION AT ELEVATED TEMPERATURES (ABOVE 73- F! 23- C), CHAMBERS SHALL BE PRODUCED FROM REFLECTIVE GOLD OR YELLOW COLORS. 1 MC-7200 CROSS SECTION DETAIL � J W d U D_ LU O 2 V) H W (a z N ¢ LJ Q 0_ Z7= rriao w� w W Z 12 y00 `` Noa LOW) _Z o w �Op O W W W'F: z Ir SHEET <WZ ADS STORMTECH MC-7200 STORMWATER DRAINAGE DETENTION FACILITY NOTES & DETAILS NOT TO SCALE 0 0 Know what's below. Call before you dig. NYLOPLAST DRAIN BASIN NTS INTEGRATED DUCTILE IRON FRAME & GRATE/SOLID TO MATCH BASIN O.D. 12" (610 mm) MIN (FOR AASHTO H-20) INVERT ACCORDING TO PLANS/TAKE OFF VARIOUS TYPES OF INLET AND OUTLET ADAPTERS AVAILABLE: 4-30" (100-750 mm) FOR CORRUGATED HDPE WATERTIGHT JOINT (CORRUGATED HDPE SHOWN) NOTES 18" (457 mm) MIN WIDTH AASHTO H-20 CONCRETE SLAB _ 8" (203 mm) MIN THICKNESS TRAFFIC LOADS: CONCRETE DIMENSIONS ARE FOR GUIDELINE PUPOSES ONLY. ACTUAL CONCRETE SLAB MUST BE DESIGNED GIVING CONSIDERATION FOR LOCAL SOIL CONDITIONS, TRAFFIC LOADING & OTHER APPLICABLE DESIGN FACTORS ADAPTER ANGLES VARIABLE 00- 360' ACCORDING TO PLANS _ VARIABLE SUMP DEPTH ACCORDING TO PLANS [6" (152 mm) MIN ON 8-24" (200-600 mm), 10" (254 mm) MIN ON 30" (750 mm)] _ 4" (102 mm) MIN ON 8-24" (200-600 mm) 6" (152 mm) MIN ON 30" (750 mm) BACKFILL MATERIAL BELOW AND TO SIDES OF STRUCTURE SHALL BE ASTM D2321 CLASS I OR II CRUSHED STONE OR GRAVEL AND BE PLACED UNIFORMLY IN 12" (305 mm) LIFTS AND COMPACTED TO MIN OF 90% 1. 8-30" (200-750 mm) GRATES/SOLID COVERS SHALL BE DUCTILE IRON PER ASTM A536 GRADE 70-50-05 2. 12-30" (300-750 mm) FRAMES SHALL BE DUCTILE IRON PER ASTM A536 GRADE 70-50-05 3. DRAIN BASIN TO BE CUSTOM MANUFACTURED ACCORDING TO PLAN DETAILS 4. DRAINAGE CONNECTION STUB JOINT TIGHTNESS SHALL CONFORM TO ASTM D3212 FOR CORRUGATED HDPE (ADS & HANCOR DUAL WALL) & SDR 35 PVC 5. FOR COMPLETE DESIGN AND PRODUCT INFORMATION: WWW.NYLOPLAST-US.COM 6. TO ORDER CALL: 800-821-6710 A PART # GRATE/SOLID COVER OPTIONS 8 PEDESTRIAN LIGHT STANDARD LIGHT (200 mm) 2808AG DUTY DUTY SOLID LIGHT DUTY 101, PEDESTRIAN LIGHT STANDARD LIGHT (250 mm) 2810AG DUTY DUTY SOLID LIGHT DUTY 12 PEDESTRIAN STANDARD AASHTO SOLID (300 mm) 2812AG AASHTO H-10 H-20 AASHTO H-20 15" PEDESTRIAN STANDARD AASHTO SOLID (375 mm) 2815AG AASHTO H-10 H-20 AASHTO H-20 18 PEDESTRIAN STANDARD AASHTO SOLID 450 mm 2818AG AASHTO H 10 H-20 AASHTO H-20 24" PEDESTRIAN STANDARD AASHTO SOLID (600 mm) 2824AG AASHTO H-10 H-20 AASHTO H-20 30" 2830AG PEDESTRIAN STANDARD AASHTO SOLID (750 mm) AASHTO H-20 H-20 AASHTO H-20 NYLOPLAT DRAIN BASIN NOT TO SCALE R=430705 TACOMA • SEATTLE • SPOKANE • TRI-CITIES 2215 North 30th Street, Suite 300 Tacoma, WA 98403 253.383.2422 TEL 253.383.2572 FV mm.ahbl.com WEB Project Title: TALBOT HILL ELEMENTARY SCHOOL Client: RENTON SCHOOL DISTRICT ANDREW HOLLENBACK 300 SOUTHWEST 7TH STREET RENTON, WA 98057 Project No. 2230870.10 Issue Set & Date: PERMIT SET JULY 9 2024 7/9/2024 NOTICE ALTERATION OF THIS DWAIENT SHALL INVMDATE THE PROFESSIONAL SEAL AND SIGNATURE PUROTI N OF THIS DON" DOES NOT DEROGATE FROM RESERVED OMM W RKNTS N IT. THIS DOO.NW IS FOR USE ONLY FOR THE PROIiCT DENTIRED N THE TIU BLOCK AND IS NOT TO BE USED FOR REPAIR, REMODEL OR AWITION TO THAT PROM OR MR ANY OTHER PROJ7. A Revisions: Sheet Title: STORMWATER DRAINAGE DETAILS Designed by: Drawn by: Checked by: JAD JAD DCN Sheet No. C4 05 of 05 Sheets