No preview available
HomeMy WebLinkAboutR-430504DocuSign Envelope ID: 6EECF5B6-602A-4E4A-B436-A317AA638878 DocuSign Envelope ID: 6EECF5B6-602A-4E4A-B436-A317AA638878 DocuSign Envelope ID: 6EECF5B6-602A-4E4A-B436-A317AA638878 DocuSign Envelope ID: 6EECF5B6-602A-4E4A-B436-A317AA638878 L J O C J I 0 I ID W I- w JOINTS IN FILTER FABRIC SHALL BE SPLICED AT POSTS. USE STAPLES, WIRE RINGS, OR EQUIVALENT TO ATTACH FABRIC TO POSTS 2"x2" 14 GAUGE WIRE, OR EQUIVALENT, IF STANDARD STRENGTH FABRIC USED FILTER FABRIC 2' MIN. ------------ 6' MAX. I I 12" I / POST SPACING MAY BE INCREASED I M TO V IF WIRE BACKING IS USED I I 4"x4" MIN. TRENCH I I� ;ul BACKFILL TRENCH WITH NATIVE SOIL L OR 3/4' TO 1-1/2" WASHED GRAVEL 2"x4" WOOD POSTS, STEEL FENCE POSTS, OR EQUIVALENT (TYP.) NOTES: 1. CONDITIONS OF USE 1.1. SILT FENCE MAY BE USED DOWNSLOPE OF ALL DISTURBED AREAS. 1.2. SLT FENCE IS NOT INTENDED TO TREAT CONCENTRATED FLOWS, NOR IS IT INTENDED TO TREAT SUBSTANTIAL AMOUNTS OF OVERLAND FLOW. ANY CONCENTRATED FLOW MUST BE CONVEYED THROUGH THE DRAINAGE SYSTEM TO A SEDIMENT TRAP OR POND. 2. DESIGN AND INSTALLATION SPECIFICATIONS 2.1. THE GEOTEXTILE USED MUST MEET THE STANDARD LISTED BELLOW. A COPY OF THE MANUFACTURER'S FABRIC SPECIFICATIONS MUST BE AVAILABLE ON SITE. ADS (ASTM D4751) 30-100 SIEVE SIZE (0.60-0.15mm) FOR SILT FILM 50-100 SIEVE SIZE (0.30-0.15mm) FOR OTHER FABRICS WATER PERMITTIVITY (ASTM D4491) 0.02 SEC' MINIMUM GRAB TENSILE STRENGTH (ASTM D4632) 180 LBS. MIN. FOR EXTRA STRENGTH FABRIC 100 LBS. MIN. FOR STANDARD STRENGTH FABRIC GRAB TENSILE ELONGATION (ASTM D4632) 30% MAX. (WOVEN) ULTRAVIOLET RESISTANCE (ASTM D4355) 70 % MIN. 2.2. STANDARD STRENGTH FABRIC REQUIRES WIRE BACKING TO INCREASE THE STRENGTH OF THE FENCE. WIRE BACKING OR CLOSER POST SPACING MAY BE REQUIRED FOR EXTRA STRENGTH FABRIC IF FIELD PERFORMANCE WARRANTS A STRONGER FENCE. 2.3. WHERE THE FENCE IS INSTALLED, THE SLOPE SHALL NOT BE STEEPER THAN 2HAV 2A. IF A TYPICAL SILT FENCE IS USED, THE STANDARD 4"X4" TRENCH MAY BE REDUCED AS LONG AS THE BOTTOM 8 INCHES OF THE SILT FENCE FABRIC IS WELL BURIED AND SECURE IN A TRENCH THAT STABILIZES THE FENCE AND DOES NOT ALLOW WATER TO BYPASS OR UNDERMINE THE SILT FENCE. 2.5. FILTER FABRIC FENCES SHALL BE INSTALLED ALONG CONTOURS WHENEVER POSSIBLE. 3. MAINTENANCE STANDARDS 3.1. ANY DAMAGE SHALL BE REPAIRED IMMEDIATELY. 3.2. IF CONCENTRATED FLOWS ARE EVIDENT UPHILL OF THE FENCE, THEY MUST BE INTERCEPTED AND CONVEYED TO A SEDIMENT TRAP OR POND. 3.3. IT IS IMPORTANT TO CHECK THE UPHILL SIDE OF THE FENCE FOR SIGNS OF THE FENCE CLOGGING AND ACTING AS A BARRIER TO FLOW AND THEN CAUSING CHANNELIZATION OF FLOWS PARALLEL TO THE FENCE. IF THIS OCCURS, REPLACE THE FENCE OR REMOVE THE TRAPPED SEDIMENT. 3.4. SEDIMENT MUST BE REMOVED WHEN SEDIMENT IS 61NCHES HIGH. 3.5. IF THE FILTER FABRIC (GEOTEXTILE) HAS DETERIORATED DUE TO ULTRAVIOLET BREAKDOWN, IT SHALL BE REPLACED. UNLESS OTHERWISE NOTED, DRAWING IS NOT TO SCALE (NTS) Ao=STD. PLAN - 214.00 •• PUBLIC WORKS PRO DEPARTMENT SILT FENCE GAZ 9/28/2018 P.bli< Works Administrator DATE DocuSign Envelope ID: 6EECF5B6-602A-4E4A-B436-A317AA638878 4' MIN. 12" DEPTH 2"- 4" ROCK 24" MIN. SETTLING DEPTH L 1 3.5' - 5' 1.5' MIN. SEDIMENT STORAGE CROSS SECTION NOTES: 1. MAYBE CONSTRUCTED BY EXCAVATION OR BY BUILDING A BERM 12" OVERFLOW DEPTH OUTFLOW CHANNEL IF r CONSTRUCTED BY _T_I n EXCAVATION 1 I 5' MAX. FILTER FABRIC FENCING 12" DEPTH 3/4" - 1 1/2" WASHED GRAVEL UNLESS OTHERWISE NOTED, DRAWING IS NOT TO SCALE (NTS) STD. PLAN - 211.00 PUBLIC WORKS APPR ED DEPARTMENT SEDIMENT TRAP GAZ 9/28/2018 1 Public Works Administrator DATE :45 AN EX\91\4 GR0 P0 R = 25' MIN. �f NSTALL DRIVEWAY CULV ERT VERT F THERE IS A ROADSIDE 7 DITCH PRESENT, AS PER CITY ROAD STANDARDS 4"-8" QUARRY SPALLS GEOTEXTILE 12" MIN. THICKNESS CONSTRUCTION ENTRANCE NOTES: 1. DRIVEWAYS SHALL BE PAVED TO THE EDGE OF THE RIGHT-OF-WAY PRIOR TO INSTALLATION OF THE CONSTRUCTION ENTRANCE TO AVOID DAMAGING OF THE ROADWAY. 2. IT IS RECOMMENDED THAT THE ENTRANCE BE CROWNED SO THAT RUNOFF DRAINS OFF THE PAD 100' MIN. 15' MIN. PROVIDE FULL WIDTH OF 6 INGRESS/EGRESS AREA NOTES: 1. CONDITION OF USE 1.1. CONSTRUCTION ENTRANCE SHALL BE STABILIZED WHEREVER TRAFFIC WILL BE LEAVING A CONSTRUCTION SITE AND TRAVELING ON PAVED ROADS OR OTHER PAVED AREAS WITHIN 1,000 FEET OF THE SITE. 1.2. FOR RESIDENTIAL CONSTRUCTION PROVIDE STABILIZED CONSTRUCTION ENTRANCES FOR EACH RESIDENCE IN ADDITION TO THE MAIN SUBDIVISION ENTRANCE. STABILIZED SURFACES SHALL BE OF SUFFICIENT LENGTH/WIDTH TO PROVIDE VEHICLE ACCESS/PARKING, BASED ON LOT SIZE/CONFIGURATION. 2. DESIGN AND INSTALLATION SPECIFICATIONS 2.1. A SEPARATION GEOTEXTILE SHALL BE PLACED UNDER THE SPALLS TO PREVENT FINE SEDIMENT FROM PUMPING UP INTO THE ROCK PAD. THE GEOTEXTILE SHALL MEET THE FOLLOWING STANDARDS: GRAB TENSILE STRENGTH (ASTM D4632) 200 LBS. MIN. GRAB TENSILE ELONGATION (ASTM D4632) 30% MAX. (WOVEN) CBR PUNCTURE STRENGTH (ASTM D6241) 495 LBS. MIN. ADS (ASTM D4751) 20-45 (U.S. STANDARD SIEVE SIZE) 2.2. DO NOT USE CRUSHED CONCRETE, CEMENT, OR CALCIUM CHLORIDE FOR CONSTRUCTION ENTRANCE STABILIZATION BECAUSE THESE PRODUCTS RAISE pH LEVELS IN STORMWATER AND CONCRETE DISCHARGE TO SURFACE WATERS OF THE STATE IS PROHIBITED. 2.3. HOG FUEL (WOOD BASED MULCH) MAY BE SUBSTITUTED FOR OR COMBINED WITH QUARRY SPALLS IN AREAS THAT WILL NOT BE USED FOR PERMANENT ROADS. HOG FUEL IS NOT RECOMMENDED FOR ENTRANCE STABILIZATION IN URBAN AREAS. THE INSPECTOR MAY AT ANY TIME REQUIRE THE USE OF QUARRY SPALLS IF THE HOG FUEL IS NOT PREVENTING SEDIMENT FROM BEING TRACKED ONTO PAVEMENT OR IF THE HOG FUEL IS BEING CARRIED ONTO PAVEMENT. 2.4. FENCING SHALL BE INSTALLED AS NECESSARY TO RESTRICT TRAFFIC TO THE CONSTRUCTION ENTRANCE. 2.5. WHENEVER POSSIBLE, THE ENTRANCE SHALL BE CONSTRUCTED ON A FIRM, COMPACTED SUBGRADE. THIS CAN SUBSTANTIALLY INCREASE THE EFFECTIVENESS OF THE PAD AND REDUCE THE NEED FOR MAINTENANCE. 3. MAINTENANCE STANDARDS 3.1. QUARRY SPALLS SHALL BE ADDED IF THE PAD IS NO LONGER IN ACCORDANCE WITH THE SPECIFICATIONS. 3.2. IF THE ENTRANCE IS NOT PREVENTING SEDIMENT FROM BEING TRACKED ONTO PAVEMENT, THEN ALTERNATIVE MEASURES TO KEEP THE STREETS FREE OF SEDIMENT SHALL BE USED. THIS MAY INCLUDE STREET SWEEPING, AN INCREASE IN THE DIMENSIONS OF THE ENTRANCE, OR THE INSTALLATION OF A WHEEL WASH. IF WASHING IS USED, IT SHALL BE DONE ON AN AREA COVERED WITH CRUSHED ROCK, AND WASH WATER SHALL DRAIN TO A SEDIMENT TRAP OR POND. 3.3. ANY SEDIMENT THAT IS TRACKED ONTO PAVEMENT SHALL BE REMOVED IMMEDIATELY BY SWEEPING. THE SEDIMENT COLLECTED BY SWEEPING SHALL BE REMOVED OR STABILIZED ON SITE. THE PAVEMENT SHALL NOT BE CLEANED BY WASHING DOWN THE STREET, EXCEPT WHEN SWEEPING IS INEFFECTIVE AND THERE IS A THREAT TO PUBLIC SAFETY. IF IT IS NECESSARY TO WASH THE STREETS, A SMALL SUMP MUST BE CONSTRUCTED. THE SEDIMENT WOULD THEN BE WASHED INTO THE SUMP WHERE IT CAN BE CONTROLLED AND DISCHARGED APPROPRIATELY. WASH WATER MUST BE PUMPED BACK ONTO THE SITE AND CANNOT DISCHARGE TO SYSTEMS TRIBUTARY TO SURFACE WATERS. 3.4. ANY QUARRY SPALLS THAT ARE LOOSENED FROM THE PAD AND END UP ON THE ROADWAY SHALL BE REMOVED IMMEDIATELY. 3.5. IF VEHICLES ARE ENTERING OR EXITING THE SITES AT POINTS OTHER THAN THE CONSTRUCTION ENTRANCE(S), FENCING SHALL BE INSTALLED TO CONTROL TRAFFIC. UNLESS OTHERWISE NOTED, DRAWING IS NOT TO SCALE (NTS) STD. PLAN - 215.10 • PUBLIC WORKS APPROVED: DEPARTMENT STABILIZED CONSTRUCTION ENTRANCE GAZ 9/28/2018 PP bli<Works Administrator DATE THE APPLICANT SHALL ERECT AND MAINTAIN A SIX-FOOT (6) HIGH CHAIN LINK TEMPORARY CONSTRUCTION FENCING AROUND THE DRIP LINES OF ALL RETAINED TREES OR A T A DISTANCE SURROUNDING THE TREE EQUAL TO ONE AND ONE -QUARTER FEET (1-114) FOR EVERY ONE INCH (1') OF TRUNK CALIPER, WHICHEVER /S GREATER, OR ALONG THE PER/METER OF A TREE PROTECTION TRACT. PLACARDS SHALL BE PLACED ON FENCING EVERY FIFTY FEET (50) IND/CA TING THE WORDS, 'NO TRESPASSING - PROTECTED TREES. " OR ON EACH SIDE OF THE FENCING /F LESS THAN FIFTY FEET (50) SITE ACCESS TO /ND/V/DUALL Y PROTECTED TREES OR GROUPS OF TREES SHALL BE FENCED AND SIGNED. INDIVIDUAL TREES SHALL BE FENCED ON FOUR (4) S/DES. IN ADDITION, THE APPLICANT SHALL PROVIDE SUPERV/S/ON WHENEVER EQUIPMENT OR TRUCKS ARE MOVING NEAR TREES. Flyrol/A 1. MIN/MUM SIX (6) FOOT HIGH TEMPORARY CHA/NLINK FENCE SHALL BE PLACED A T THE FROM TREE DR/PL/NE OR DES/GNA TED L/M/T OF DISTURBANCE OF THE TREE TO BE SA I/ED. FENCE SHALL COMPLETEL Y ENCIRCLE TREES). INSTALL FENCE POSTS USING PIER BLOCK ONL Y. MOD/F/CAT/ONS TO FENCING MA TER/AL AND 6' LOCAT/ON MUST BE APPROIED BY PLANNING OFFICIAL. 2. TREATMENT OF EXPOSED ROOTS DURING CONSTRUCTION. FOR ROOTS OVER ONE (1) INCH DIAMETER DAMAGED DURING CONSTRUCTION, MAKE A CLEAN STRAIGHT CUT TO REMOVE THE DAMAGED PORTION OF ROOT. ALL EXPOSED ROOTS SHALL BE TEMPORARI Y COVERED WITH DAMP BURLAP TO PRE I/ENT DRYING, AND COVERED WITH SOIL AS SOON AS POSSIBLE. J NO STOCKPILING OF MATERIALS, VfH/CULAR TRAFFIC, OR STORAGE OF EQUIPMENT OR MACH/NERY SHALL BE ALLOWED WITHIN THE LIUIT OF THE FENCING. FENCING SHALL NOT BE MOVED OR REMOVED UNLESS APPROVED BY THE CITY PLANNING OFF/C/AL. WORK W/TH/N THE PROTECTION FENCE SHALL BE DONE MANUALL Y UNDER THE SUPERV/S/ON OF AN ON -SITE ARBOR/ST AND WITH PRIOR APPROVAL BY THE CITY PLANNING OFFICIAL. 4. ALL AREAS WITHIN THE REQUIRED FENCING SHALL BE COVERED COMPLETEL Y AND EI/ENL Y W/TH A M/N/MUM OF THREE (3') OF BARK MULCH PR/OR TO INS TALLAT/ON OF THE PRO TECT/l/E FENCING. :45 AP 5" MAX. DRAINAGE GRATE TRIM GRATE FRAME _ C- OVERFLOW BYPASS BELOW INLET GRATE DEVICE SEDIMENT AND DEBRIS_ 3b FILTERED WATER SECTION VIEW DRAINAGE GRATE (RECTANGULAR GRATE SHOWN) RETRIEVAL SYSTEM (TYP.) OVERFLOW BYPASS (TYP.) BELOW INLET GRATE DEVICE ISOMETRIC VIEW NOTES: 1. PROTECTION SHALL BE PROVIDED FOR ALL STORM DRAIN INLETS DOWNSLOPE AND WITHIN 500 FEET OF A DISTURBED OR CONSTRUCTION AREA, UNLESS THE RUNOFF THAT ENTERS THE CATCH BASIN WILL BE CONVEYED TO A SEDIMENT POND OR TRAP. 2. INLET PROTECTION SHALL BE USED TO PROTECT THE DRAINAGE SYSTEM. 3. THE CONTRIBUTING DRAINAGE AREA MUST NOT BE LARGER THAN ONE ACRE. 4. SIZE THE BELOW INLET GRATE DEVICE (BIGD) FOR THE STORMWATER STRUCTURE IT WILL SERVICE. 5. THE BIGD SHALL HAVE A BUILT-IN HIGH -FLOW RELIEF SYSTEM (OVERFLOW BYPASS). 6. THE RETRIEVAL SYSTEM MUST ALLOW REMOVAL OF THE BIGD WITHOUT SPILLING THE COLLECTED MATERIAL. 7. PERFORM MAINTENANCE IN ACCORDANCE WITH STANDARD SPECIFICATION 8-01.3(15). S. ANY SEDIMENT IN THE CATCH BASIN INSERT SHALL BE REMOVED WHEN THE SEDIMENT HAS FILLED ONE-THIRD OF THE AVAILABLE STORAGE. THE FILTER MEDIA FOR THE INSERT SHALL BE CLEANED OR REPLACED AT LEAST MONTHLY. UNLESS OTHERWISE NOTED, DRAWING IS NOT TO SCALE (NTS) STD. PLAN - 216.30 a, ,} PUBLIC WORKS JAPPR95ED: DEPARTMENT CATCH BASIN INSERT GAZ 9/28/2018 1 P.buc wo ,Ad-i.n.ro. DATE TREE OR/PL/NE TREE PROTECT/ON FENCING NO SCALE SURVEYED: :45 AN DESIGNEOTHERS FLA V/0 BA/NOTTI DRAWN: CHUCK FEML/NG CHECKED: M/CHAEL MOODY NO. REVISION BY DATE APPR APPROVED: M/CHAEL MOODY NT TREE 'US T MAX. :45 AP SECTION A SECTION B NOTES: 1. CONDITIONS OF USE 1.1. WHERE THERE IS CONCENTRATED RUNOFF FROM DISTURBED AREAS TO AND FROM SEDIMENT PONDS OR TRAPS. 1.2. TO CONVEY RUNOFF INTERCEPTED FROM UNDISTURBED AREAS AROUND THE SITE TO A NON -EROSIVE DISCHARGE POINT. 2. MAINTENANCE STANDARDS 2.1. ANY SEDIMENT DEPOSITION OF MORE THAN 6 INCHES SHALL BE REMOVED SO THAT THE CHANNEL IS RESTORED TO ITS ORIGINAL DESIGN CAPACITY. 2.2. THE CHECK DAMS SHALL BE EXAMINED FOR SIGNS OF SCOURING AND EROSION OF THE BED AND BANKS. IF SCOURING AND EROSION HAS OCCURRED, AFFECTED AREAS SHALL BE PROTECTED BY RIPRAP OR AN EROSION CONTROL BLANKET OR NET. UNLESS OTHERWISE NOTED, DRAWING IS NOT TO SCALE (NTS) Aoftk STD. PLAN - 217.40 .} PUBLIC WORKS PPR D: DEPARTMENT DITCH CHECK DAMS GAZ 9/28/2018 1 Publ Works Administrator DATE TABLE B. .I.2.B EROSION CONTROL SEED MIX Common Name/Latin Name % Species Composition Desired Seeds per Square Foot PLS Pounds/Acre Spike bentgra sI[Agrostrs exarata 6 9 0.1 California bromelBromas carinatus 15 23 9.8 Tufted hairgra s/Deschampsla cespltosa 15 23 0.4 Blue wlldrye/Elyrrlus glaucus 18 27 10.7 California oatgrass.1401anthorlia caiifomica 18 27 5. Native red fescue/Festuca rubra var. rubra 18 27 2.4 Meadow barley/Hordeum brachyarltherum 10 15 7. MIX ASSUMES 150 SEED PER SQUARE FOOT AND SHOULD BE APPLIED AT APPROXIMATELY 37 POUNDS OF PURE L/I/E SEED PER ACRE R-430504 SCALE: VERTTAL- AD 1 1988 83/1 CITY 0 F HORIZONTAL- NAD 1983/1991 R RENTON ONE INCH DATUM AT FULL SCALE Planning/Building/Public Works Dept. IF NOT ONE INCH SCALE ACCORDINGLY PROJECT NO. 2008 1K 1000 :45 AN 0 J ,�,P�F• qf.M •�� o yfy pd CIVIL ENGINEERING LANDSCAPE ARCHITECTURE PLANNING 41843DESIGN SURVEYING �.`'• GISTER F4I1NAL ENVl 12100 NE 195th St, Suite 300 Bothell, Washington 98011 425.885.7877 V 04/02/25 IN COMPLIANCE WITH CITY OF RENTON STANDARDS O DEVELOPMENT ENGINEERING 0 HHuynh 04/17/2025 W JONES RENTON SHORT PLA T DATE. W 3102 PARKA VEN, RENTON, WA 98056 FIELDBOOK: PAGE O TEMPORARYSEDIMEVTAND DRAWING NO: 3-1 EROSION CONTROL DETAILS T: OF, SHEEP: 6 F:34