Press Alt + R to read the document text or Alt + P to download or print.
This document contains no pages.
HomeMy WebLinkAboutR-43051012" IE 191.22
CONNECT TO EX CB
L
O 0
C'7
STORM DRAIN CATCH BASIN
0 I RAM= 193.42'
�N) 12" CPP= 191.22'
Q /(Q) 1?" rDD- 191.32'
uJ T I NEW 12" PVC /E 191.22 (5)
0
Q 1 V 1 /
208LF 12" DI
I / 00.0405
o I
o
/ I
N
I II 1 1
OHP ; \
w W r
' w Q a I I ONP
V, ' x
W F --- -- -
SS -25.00 / N
9
1 � ore U)
0 I / SEWER /ANHOLE /
(W,�8" CONC. 1,i.=191.63'
8" CONC/LE.=192.23'/
oc)a I
25 w 25 O
CD
N O
SEE RIGHT CB 1
PETERSON MARK S
STA. 3f38.20, 12.77' LT &• MICHELE L
TYPE 1, SOLID LOCKING LIDAPN 5342101634
RIM 180.63
12" IF /N 178.11 (5)
12" If /N 178.11 (W)
STA. 11f63.56, 17.30' RT
TYPE 1, VANED GRA TE
RIM 203.77
8" If /N 200.32 (E)
12" IE OUT 199.65 (N)
P PN 33
P
SEWER MANHOLE
RIM EE=204.09
(E) 8" CC
STA. 10* 49. 79, 17. 30' RT
TYPE 1, VANED GRATE
RIM 206.29
12" /F OUT 202.28 (5)
41LF 12" PVC
CB 3 ®0.1627
STA. 10109.27, 17.30' RT
TYPE 2-48; SOLID LOCKING LID
RIM 205.17
12"lE/N 195.61 (E)
12"IEIV 195.61 (N)
12" lE /N 195. 61 (S)
22LF 12" PVC
00.0068
10f00.00, PARK AVE N -
5f00.00, ROAD A_\
STORM DRAIN CATCH BASIN -
RIM= 200.31'
(W) 12" IP= 198.84'
SEE LEFT _
Iu
o �6 I / /-+ 12
II � I l 11+ 5, 46.56' RT / / 0\-� 6 I
/ I / 10' PRIVATE STORM 3
F12 D/ TYPE 2-48, SOLID LOCKING LID DRAINAGE100..0405 RIM 12.58 �ORL
/ 6" 11lN 204.15 (E) 8 CLEANOUT / EASEMENT ENE N PRE 9
I I I RIM 21316 G P S ON
/ II " 8 /� OUT 203.99 (W) 6" 1E 206.27 _(E% � R �P
I 31LF 8 PVC I 10' DRIVEWAY ESMT 20' INGRESS, ECjRESS & UTILITIES
l I 0 0.11�4 6 /E 206.27 (W) /
/ REC NO 4731181 ESM'T PER (R2)
l / I 6" IE 206.27 (S) i
------f--------------------- ---- - - " __ _ ---- --
\ PROPOSED PROPERTY F 1Q4LF 66 PVC- - --�- ---------- �/ /
------------------ a -
?o� L/NE (TYP) - 2� ---
N89 06'14 "W 257. 00 000580 / i
4 I
PROPOSM-FINISH
/ •A4° 7LF 6" PVC GRADE CONTOUR (TYP) /
z / j 5LF 6" PVC ®0.1000 8 CLEANOUT
6 /E 207.19 0 0.1840 RIM 215.77 i
j 6" lE 213.00 6" lE 212.30 (S) / EX/STING GROUND
11LF 6" PVC 6" If 212.30 (W) / CONTOUR (TYP) /
00.1927 °: - / l
I I 10 LF 12" 2 I ° ° / A OF ��
I I I I D/ SLEEVE PAD 216.0 � ° . ' 3 \ 0 P� VP 0
Q I I I a° ° d .. PAD 217 0 \AE PyM PAS ROE 0 1 � ti
° ° aLa ° °
CL I I PROPOSED 9' D/A. INFIL TRATION DRYWELL ° d ° ° 40' PUB /C STORM G 0 \�\GO\�\S\�� 6�
BOTTOM OF ORYWELL EL.= 2 70 4. a A I� DRA/NGE & PSG\ \ P
TOP OF DRAIN ROCK EL. = 213.70 ° I ° UT/L/TIES�EASEMENT
REQD DRAIN ROCK VOLUME= 350 CFI ° ° ° °
I I ° ]JA TRACT C
I(ACCESS & UTILITIES)
IE 212.96
a4 I Iff1 TRATION DRYWELL (TYP)
I a % 1
2LF 6 PVC I SEE C.O.R. STD DETAIL, SHEET C4.31
I ° A PAD 216. 0 90.0200 a � 1'
° PROPOSED 10' D/A. INFIL TRA -ION DRYWELL
\ YD 1 4 / Q BOTTOM OF DR EL. = 20810
J 5LF 6. , VC 1
o \ 6LF 12" PVC RIM 214.60 Q : °° f' :. a Q Q ®0 0 TOP OF DRAIN ROCK EL.= 214. �0 A. JON S
d 9 0. 0433 6" IE 21J 70 (SE a % O READ DRAIN ROCK VOLUME= "5 CF APN 33421�3215
6 /E 213.00 (N) 9' �i �' ° 3102 PARK V VE N
8LF 12" 6" If 21370 (W) ° A . I ° 4 RENTON 9 056
PVC 14LF 6" PVC ° PAD 2170 PARCEL
00.0212 YD 3
1 » 0 0. 0200 , IF 213 46 R/M 215.18 )
° l RIM CLEANOUT 6 ��IF 213.98 00 / 2LF 6" PVC 9 0.0200 6 lE 214.10 (SW)
6 / /E 213.50 (N) /
6" lE 213. 60 (NW) " l
" L 6TPVC f 1E214.10(E)
l )
---_6" IE 213,98 (W) 6" IE 21J 98 7�" DI 00.8700 � f '' 15LF 67 PVC-0 0 O 93 /
I� ®0.02 214 24 6" IE 214.39 /
- 2 6" IE 214.39 /
191F 6" Dl ® 0 2442
I
I
I
I
I
-I
-0HP HP OHP 7EEI ` oe a° ° 4'.a -- 26LF 6 PVC °°0023 ° h
°eee •
' • � eaa ° 6" CL
:``' ` ° BOLE 1 H PVC 0 0.2346 18 4. ° RIM 214.79UT
OHP OHP OHP ° /4 » »
SD �5D / SD SD � 1 OHP
gee.=
" sq SD D / ® .1�22 n pVC l 1 23 F, 6 V� D /E 209 75 (NE)
w w w " w- * - , - 36L 1.0192 13 ® a097 6" lE 209.75 (SW) 6" CLEANOUT o
® 0.05 12 S RM �LIN N 4 �- $' ° /0° a RIM 216.61 c
SS ss ss s5 �S- /
� �_�� 4 0_0 s5 ss /S �- � � ti / ti ti / ti � � a � 6 /E 209.75 (E O _ ti
ss ss / s 5 ° �o. ° °° " 6 /E 214.72 �
6f00 / 45 6 VC o
I SEE PROF/LE D-D 'N 31S�T S �- -- I "'I - - - / - ` rs °0422 6 lE 214.72 (W) _
STORM CROSSING" SHEET C4.22 N 31 S T S T 67LF 12 PVC �, \ f R OA f-1 / - ° . 6 /E 215.00 6 /E 215.00 (NE) 5
a
/ -- ------ -- ---� -- \ ®00093 --l_J I \ (PUBLIC) NJAL
p YD2
N
20LF 6" D/ PAD 217.7
\ -�-------- \ 12 ®0.0140 R/M2>6.84
G G G 103LF 1 " Dl G -G - - - - - G ,� \ \ ® I Of 00, ROAD B = 8LF 6 �, PV 6 �� lE 214.82 ((VW)
0 0.1484 I � I � �,a � � � °, . ° 6*46.61, ROAD A - _ _ 01 0 � 6" lE 215.00 6" 1E 214.82 (E)
CB 8132 TYPE \ 6 /E 214.20
vIANHOLE / ° ° a d 8LF 6" PVC
S\
RIM EL=169.24 CB �� �\
12"CONC(E)IE=167.04 G'B 2 CIM EL=205.23' I � ® �o�, )1,22ZN2" PVC TRACT B LF 6" PVC 2LF 6" PVC ®0.0225 %
© 0.0200
12"CONC(W)IE=166.9� STA. 3f47.00, 13.00' RT STA. 4f50.00, 1300' RT E,S) 8" CONC. I.E.-198.43 �� 0 0.0600 � c (A SS & URL/TIES) �1 r�� 0143 10' ACCESS �
1 �" � � � IE 214.1 ,�
I EASEMENT
TYPE 1, SOLID LOCK/NG LID TYPE 1, SOLID LOCKING LID W� 8" CONC. E.=198.23' oo / \ 1 10 o
RIM 181.55 RIM 198.25 ` S89 04 38 E >9D. 99 \ I
12" lE /N 179. 55 (E) 12" lE /N 194.84 (E) \ <'B 7 / ' "
12" IE OUT 179.55 (N) 12" IE OUT 194.84 (W) 0 5 I \� / I ( STA. 5f40.66, 11.41' RT
STA. 9f60.58, 17.30' RT ✓I / • \ TYPE 2-48' VANED GRATE q \ I�
TYPE 1, VANED GRATE I \ RIM 204.30 CB / 0
MOORE WAL TER421013 C RIM 20388 I \ ,12" IE OUT 197.86\(NW) - STA. Of70.50, 0.00
APN 3342101350 » � .. »
12 /E OUT 199.00 (N) I \ TYPE 2-48 , VANED GRATE 6 CLEANOUT 10 PUBLIC STORM
RIM 21,, O RIM 215.81 � DRAINAGE &
o CB STA. 5f31.66" 1E IN 207.50 (NE) 6" IE 209.40 (E) UnL/�IES EASEMEN�- /
Fz
7 8.45 L T
UTILITY CROSSING TABLE I N I TYPE 2-48; 'THRU CURB INLET 6" lE /N 207.50 (SE) 6" lE 209.40 (NW) o �
RIM 204.49 \ 6" lE /N 207.50 (NW)
CROSS/NG # UPPER NETWORK UPPER P/PE IF LOWER P/PE CROWN LOWER NETWORK CLEARANCE � i � CLEANOUT I N 12" /f /N 196.54 (E) 12" lE OUT 207. 00 (W) �
2I M EL= 203. 84' z I 12- IE /N 196.54 (SE) PIPE CROSSING (TYP) PROPOSED 9' D/A. INFIL TRATION DRYWELL TRACTA
1 STRM 206.88 205.20 SSWR 1.68 12 If OUT 196. q4 (W) SEE UTILITY CROSSING BOTTOM OF DRYWELL EL. = 209. 00 2�1�h i
(TREE RETENT/ON) �
EX/STING 12" �'B 9 TABLE, THIS SHEET TOP OF DRAIN ROCK EL. = 215.00 0 �
2 STRM 209.32 205.40 SSWR 392 � o � ,
WATER MAIN I 25' 25' �I STA. 6f 11.13, 12.25' L T L 0 T 3 9 REQD DRAIN ROCK VOLUME= 333 OF
3 SSWR 199.54 197.88 STRM 1.66 3
TYPE 1, VANED GRATE CA
4 SSWR 198.86 196.60 STRM 2WATER MAIN RIM 211.21
25 STING I 1 \ CAROLYN' JO �S TRACTD
WAN \ 15�
y� 12" IE /N 206.31 (E) (FUTURE
„ APN 3342103250 C9NY�YANCE)
5 STRM 208.36 205.47 SSWR 2.88 I --- _- - _ 12 If OUT 206.31 (W) PARC L B \ ----� X -
6 WATER 210.28 205.22 SSWR 5.05 I 1125.0o wQ BA YfRER, x x T, ,
9 WATER 200.81 198.55 STRM 2.26
STA. 2-48�" SLID L T 589 04 38"E 60. 01
TYPE 2-48 , SOLID LOCKING LID 0 P 5\ X
10 WA TER 200.85 196.54 STRM 4.31 I RIM 204.92 \ \N 032
0HP OHP 12" /F /N 196.37 (E) RG\ �21 '
12 WATER 211.07 209.41 STRM 1.67 I 12" IE OUT 195.87 (W) 8 PN 33
13 WA TER 210.31 208.45 STRM 1.86 I ADS BA YF/L TER WATER P
QUALITY CATCH BASIN _ELEVEN
14 WA TER 210..38 208.71 STRM 1.67 0 SYSTEM. SEE DE TA/L A P N 33 42103 248
16 WATR 200.63 196.29 STRM 4.34 I SHEET C4.31. R -43 0 510
SURVEYED: SCALE: VERTICAL
17 HA T? 199.69 196.25 STRM 3.45
OTHERS HORIZONTAL- N D 1983/1991 CITY 0 F
DESIGNED:
18 STRM 206.56 204.35 SSWR-SERV 2.21 FLA V/0 BA/NOTTI RENTON
DRAWN:
CHUCK FELLING ONE INCH
23 STRM 206.84 205.08 SSWR 1.76 DATUM
CHECKED: AT FULL SCALE Planning/Building/Public Works Dept.
M/CHAEL MOODY IF NOT ONE INCH
24 STRM 210.06 20540 SSWR 4.66 NO. REVISION BY DATE AP P R APPROVED: SCALE ACCORDINGLY
M/CHAEL MOODY
NOTE:
INFIL TRA TION DRYWELL SIZING SHALL BE
I
REVIEWED AT THE TIME OF BUILDING PERMIT
I
I
I
I
I
I
I
I
I
I
I
I
I
--I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
SCALE: 1" = 20'
0 10 20 40
STORM LEGEND
STORM PIPE
STORM SERVICE
❑❑ STORM STRUCTURE
STORM PIPE FLOW ARROW
EXISTING STORM PIPE
PR/VA TE STORM LINE
PUBLIC STORM PIPE
SURFACE LEGEND
EX GROUND CONTOUR M4JR
EX GROUND CONTOUR M/NR
210 FINISH GRADE CONTOUR MA✓R
212 FINISH GRADE CONTOUR MINR
NOTE.-
1. INFIL TRA -ION TRENCH SIZING SHALL BE REVIEWED
AT THE TIME OF BUILDING PERMIT.
I CAUTION: UT/L/TYCO/VFL/CTS I
LOCATIONS OF UTILITIES AS SHOWN ON THESE PLANS ARE BASED ON UVWR/F/ED PUBLIC
INFORMATION AND SHALL BE FIELD VERIFIED BY THE CONTRACTOR.
PR/OR TO CONSTRUCTION, CONTRACTOR SHALL CONTACT ALL UTILITY COMPANIES, AND CALL
UTILITY LOCATE ® 811.
PR/OR TO CONSTRUCTION, CONTRACTOR SHALL POTHOLE EX/STING UTILITIES, CONTACTING THE
SURI/EYOR OF RECORD TO SURVEY THE HORIZONTAL AND VERTICAL LOCATIONS AND VfR/FY
THE LOCATION, DIMENS/ON, AND DEPTH OF ALL EX/STING UTILITIES ON THE PROJECT SITE.
IN ADDITION, CONTRACTOR SHALL POTHOLE LOCATIONS OF NEW UTILITY CROSSINGS TO
VERIFY NO CONFLICTS EXIST.
IF CONFL/CTS EXIST, THE CONTRACTOR SHALL CONSUL T CORE DESIGN, INC. TO RESOL VE
CONFLICTS PR/OR TO PROCEEDING WITH CONSTRUCTION.
ALL PIPES WITH LESS THAN ONE AND A HALF FEET (1.5) OF VERTICAL SEPARATION SHALL
HAVE- ETHAFOAM, OR APPROI/ED EQUIVALENT, PLACED BETWEEN THE PIPES TO MAINTAIN
SEPARA -ION.
C\1
O
C\1
u
PROJECT NO. 2008 1K
oF ,Z,P�• Asy M
,� •�� ry pd CIVIL ENGINEERING
LANDSCAPE ARCHITECTURE
.ti Z• PLANNING
41843DESIGN SURVEYING
O,n •LISTER
F`ESIaNAL ENVl 12100 NE 195th St, Suite 300 Bothell, Washington 98011 425.885.7877 Q
O4/02/25
IN COMPLIANCE WITH CITY OF RENTON STANDARDS O
DEVELOPMENT ENGINEERING ;+ Surface Water Enginering
HHuynh 04/17/2025 JFarah 03/03/2025
JONES RENTON SHORT PLA T DATE. W
3102 PARKA VEN, RENTON, WA 98056 FIELDBOOK:
PAGE:
DRAINAGE CONTROL DRAWING NO: O
C4.01
PLAN SHEET: 12
OF: 34