NOTES:
I�
1 I I LJ
JON�S
CD
/ - IQ
EXISTING SIDE SEE
WER RE P PR/ I 10' DRIVEWAY ESMT I 1 20' INGRESS, E SS & UTILITIES
SON �N �30 TO BE CAPPED AND PROPOSED PROPERTY REG No 4731181 ESM'T PER (R2)
PE�O SOS �21016 / l ABANDONED ---- ------------- LINE (TYP) - - � /
------------------ --- -------------
PPN SSMH / /
RIM EL=204.09 06 \ 212� ti /218
8"CONC(E)IE=196.59 -25.00 dN.
8"CONC(N)IE=196.29 0� )
55CO7
/ .)4. _ j _) 18LF 6" PVC 6 /E 210.38
z / - -3SCO 5 90.1489 6" IE 209.59
/ PROPOSED FINISH 6, lE 6 1 _
I LU I ( / GRADE CONTOUR (TYP) 6" If- 206.91
SSCo 6
d
EX/STING WATER METER I I I .; I 2 » ° °' d °. ° ° 4LF 6 PVC 3 0� 0 P� F
TO BE REMOVED I I I PAD 6 IF 09.16 I Q . a . ° 90.0575 PAD I P\ PNSIRoEN
SAL VAGED BY CITY (TYP) � 216.0 . ' ° ° l 217.0 / �N \0L� G N0'
° » d .a ° °
I I 13LF 6 PVC : I ° N N N
I I / 00.1415 ° /GSN\NGS\�\SP
° d °
° - : ° »
EX/STING GROUND 6" IF 211.00 a I° , ° ° d 6 /E 210.61
��RSO ��E 1016� I . ll /
CONTOUR (TYP) '° ° ` ° ° 1 f 44.84, 13.27' RT �
0 SSCO 5A
6 /E 206.9 2" BLOWOFF ASSEUBL Y /
FQ 6" lE 206.91 ,o PER CORD STD. PLAN 340.1 I {'
CUT AND CAP EXISTING I WITH CONC. BLOCKING
WATER SERVICE AT MAIN / I \ 8LF 6" PVC I I \ 0' 50NG ON
PER CURRENT PUBLIC / I 00.2812 >f44.83, 5.96' RT I I G J �0 g
WORKS SPEC/F/CA TONS / \ ° d SSCO 5 I o 0 ON ON 23
Lq d ° 91LF 6 PVC ° ° I ° m ° 6 /E 206.91 CAP (M✓� I N �N, I \N� 0 G N�G�2� 0�
s'N' H `t 0 0.0296 ° WITH CONC BLOCKING
I ( J ON 3�
r IM EL=205.23 O / Q ° 6 /E 206.91 I SE QN
8"CONC(E,S)IE=198.43 °' » a I` d
8"coNc(w)IE-198.23 I \ 1 DOMESTIC WATER METER ° : ° ° , o' ..�. TRACT C I L-- P
NEW 8" IE 198.43 I WITH PR PROVIDED FOR a ° 10 O (ACCESS & UTILITIES)
I I 1 \ EACH LOT (TYP) \ ES 15
a p 40' PUBLIC STORM J0N �O�E N l
4f95.91, 5.33' RT \ ° '\ \ l 88LF 6" PVC a a a DRA/NGE & 4 \ P �3 R� P
" I ° PAD 0 0.032.3 UTILITIES EASEMENT \ PPN Q P g8 1
CONNECT TO EXISTING 8 MAIN I I I \ 216.0 \ N PIPE CROSS/RZ�� ORN
I -REDUCER (FL) 6If- 209.93 SEE UTILITY CROSSING
GE\ )
Q P
FINAL CONNECTION TO EX. I I I I ° I I 6" CLEANOUT 2LF 6" p BLE, SHEET C5.21. i
8 WATER MAIN TO BE
DONE BY CITY FORCES PER / I I i 169LF 8" PVC 6" If 20L I l 1.4J50 SSCO 4
6 /E 209.13
COR STD PLAN 300. 4 I I ; ` 00.0420 6" lE 204.34 e 6" lE 212. 00 _ 6" lE 209.13 /
CB, TYPE I I \ ' 2 4 ' -
RIM EL=200.31 ° \ 24 26LF 6" PVC
12"DI(W)IE=198.84 I 2 00.1400
\�
ooze / I °O ' ' : ° ° 23 ° SSCO 3
°HP ° " o2LF 6" PVC 18 14 6 /E 209.75
SD _
006000 6" lE 209.75
-w w ,'I \ » l �,� 13 ° �. 20LF 6" PVC
N r] co 28LF 6 PVC `� ° d ° 0 0.1470 ptitio SS A /s ue- SS SS `�' 0 0(0314 / s �°°'. a SDe6 G
J - - \` 6» lE 206.81
N 31 S T S T \ [ OADW11771F 8" DI / " 6 /E 206.81
_ 6LF 8" 9LF 6 PVC
-----�,-J--- ---1 (PUBLIC - 6 E o 3�7� » 5 90.IJ78
r'H-SFr ` i N N N N N 12 ° 23LF 6 DI
PAD
" 7.0
Lc �r c 6 /E 120J 46 2>
- - - 214 N
\ / - - SSMH
° . °� • q tr I 6 3.23, 6.35RT STA. 6f76.11, 7' L
W /
1Of00.00, PARK A l/E N = - z ® a \ �`E�¢ 07 5LF 8-D1 10' CAP (UJ) TYPE 1-48" %
_
5f00.00, ROAD A N ° \ �� \ \ _ WITH CONC BLOCKING RIM 215.65 (
206 I 8 If OUT 205.52' �W)
w 25.00 'IN 6" 1E 205. 49
Q
I \ \ TRACT B I I 10' ACCESS
CONNECT TO EX SSUH I 6f70.65, 6.33 RT EASEMENT
8" 1E 198.43 J w' - / I I \ (ACCESS & UTILITl�S) 6" If-204.22 \
POL YP/G STA T/ON I
, 0f50.00, ROAD B =
\ 6f 46.61, ROAD A
FIRE HYDRANT WITH SHEAR
BLOCKING PER DETAILS 310.1
& 310.2 ON SHEET C5.32 &
C5.33
REN �2 5
G\�� 33�210
PQN
N
SCALE: 1" = 20'
0 10 20 40
SEWER LEGEND
SEE WER P/P
co
SEWER STRUCTURE
SEWER SER146F
� SEWER P/PE FLOW ARROW
- - SEWER EASEMENT
EX/STING SEWER PIPE
WA TER LEGEND
WATER MAIN
)7d IN[
WATER F/TT/NG
0
FIRE HYDRANT
WATER METER
❑o
BLOW -OFF ASSEMBL Y
101
POL YP/G STATION
Q
PRESSURE REDUCING VALA Vf
- -
WATER EASEMENT
EX/STING WA TER PIPE
SURFACE LEGEND
EX GROUND CONTOUR MA✓R
EX GROUND CONTOUR M/NR
210 FINISH GRADE CONTOUR MA✓R
212 FINISH GRADE CONTOUR M/NR
CAUT/ON.- UTILITY CONFLICTS
LOCATIONS OF UT/L/T/ES AS SHOWN ON THESE PLANS ARE BASED ON UNVERIFIED PUBLIC
INFORMATION AND SHALL BE FIELD Vf-R/F/ED BY THE CONTRACTOR.
PR/OR TO CONSTRUCT/ON, CONTRACTOR SHALL CONTACT ALL UTILITY COMPAN/ES, AND CALL
UTILITY LOCATE 0 811.
PR/OR TO CONSTRUCT/ON, CONTRACTOR SHALL POTHOLE EXISTING UT/L/TIES, CONTACTING THE
SURVEYOR OF RECORD TO SURI/EY THE HORIZONTAL AND VfRT/CAL LOCATIONS AND VERIFY
THE LOCATION, DIXNS/ON, AND DEPTH OF ALL EXISTING UTILITIES ON THE PROJECT S/TE.
IN ADD/T/ON, CONTRACTOR SHALL POTHOLE LOCATIONS OF NEW UTILITY CROSSINGS TO
Vf-RIFY NO CONFL/CTS EXIST.
IF CONFL/CTS EXIST, THE CONTRACTOR SHALL CONSUL T CORE DES/GN, INC. TO RESOL Vf
CONFLICTS PR/OR TO PROCEEDING WITH CONSTRUCTION.
ALL PIPES WITH LESS THAN ONE AND A HALF FEET (1.5) OF VERTICAL SEPARATION SHALL
HAVE- ETHAFOAM, OR APPROVED EQUIVALENT, PLACED BETWEEN THE PIPES TO MAINTAIN
SEPARA T/ON.
w 61662J, 6.34 RT \
1. MIN/MUM OF 18-INCH VERTICAL SEPARATION BETWEEN SEWER, I z \ \ \ FIRE HYDRANT ASSEMBLY 10' PUBLIC STORM
WATER AND STORM LINES WHERE MIN/MUM SEPARATION /S 6f52.61, 6.33 RT DRAINAGE &
\ » 1-8 x6 TEE (M✓xFL)
NOT FEAS/BLE, NON -POTABLE WATER PIPE SHALL BE RIM-203.84 I Q C 1-81x4 TEE (MJXFL) 017LWS EASEMENT
PRESSURE RATED PIPE (PVC C900, D1,, OR EQUAL) I N I \ \ 1-4" GATE VAL Vf- (FLXUJ) 1N6 GATE VAL l/E (M✓xFL) PROJECT NO. 20081 K
W \ \\ W/ CONC BLOCK/NG W7H CONC BLOCK/NG
2C . ALL ONSTRUCT/ON SHALL BE /N ACCORDANCE WITH THE CITY I o I \
OF RENTON STANDARD SPEC/F/CA TONS I I
3. CONTRACTOR SHALL FIELD VERIFY ALL CONNECTIONS TO I z I \ \
EXISTING PIPES FOR PROPER RTT/NGS AND DEPTH. I \ 3g &
4. ALL WATER F/TT/NGS AND VALVES WITH MECHANICAL JOINT I� 25' I 25' I II vo NERD j0 3250�
(M✓) ENDS SHALL HA VE A WEDGE- TYPE RETAINER GLAND
EQUAL TO MEGALUG SERIES 1100. I Q I\ I GPRO
5. SEE SHEET CA01 FOR U17LITY CROSSING TABLE. ER 50 I fD-z \ \ I P? P PR \
25.00 ---- -- / X X -
M PN <Of
I'
P IX I
I < \NID 3251
I
oHP OHP 80�G \A���10
I I I PPN
NO.
N
O
N
u
\ ti�;PoF�wAsyMpd CIVIL ENGINEERING
\ ,2j TRACiA" - �;�P� y�'• -4 LANDSCAPE ARCHITECTURE
2 (TREE RETENTION)
PLANNING
TRACT D o • G41843���� DESIGN SURVEYING
(FUTURE F`�SIBNAL ENVl
CONVEYANCE) 12100 NE 195th St, Suite 300 Bothell, Washington 98011 425.885.7877 V
-21 / 04/02/25
X X X
\ _ IN COMPLIANCE WITH CITY OF RENTON STANDARDS O
�\ DEVELOPMENT ENGINEERING t^
�'-�- vJ 7_ELE
VEN 48 HHuynh 04/17/2025
ApN 33421032 Z
WASTEWATER UTILITY WATER UTILITY r
S 430501 W 430501 jstowell 03/04/2025 ABDOUL GAFOUR 03/06/2025 W
SURVEYED: SCALE: DATE:
JONES RENTON SHORT PLA T
VERTICAL: NAVD 1988 � CITY 0 F �u
OTHERS HORIZONTAL- NAD 1983/1991
DESIGNED: O
FLAWO BA/NOTT/ 3102PARKA VEN, RENTON, WA 98056 FIELDBOOK:
RENTON PAGE
DRAWN: I;R
O
CHUCK FEML/NG ONE INCH DATUM DRAWING NO:
CHECKED:
AT FULL SCALE Planning/Building/Public Works Dept. SEWER &WATER PLAN C5, 01 \l
U/CHAEL MOODY IF NOT ONE INCH
REVISION BY DATE AP P R APPROVED: SCALE ACCORDINGLY SHEET: OF:
M/CHAEL MOODY 18 34