Press Alt + R to read the document text or Alt + P to download or print.
This document contains no pages.
HomeMy WebLinkAboutT-430504Lij
Q
z
w
Ll
EX R/W — —
E
0
rZ
W
y
�— G �I
I
w w w w
9f00 w w w-
. — I— _ —
DA DV A 1/C N
• ss
2 / 1\
ILLUMINATION WIRING SCHEDULE
RACEWAY
CONDUIT
SIZE
ILLUM.
#8
SERVICE
#2
EQUIP.
GROUND
NO.
1
2" SCH80 PVC
2
1
2
2" SCH80 PVC
4
1
3
3" SCH80 PVC
3
4
3" SCH80 PVC
4
1
* EQUIPMENT GROUND SIZE SHALL BE EQUAL TO OR
LARGER THAN THE LARGEST WIRE SIZE IN THE
CONDUIT.
ILLUMINATION LEGEND
EX
NEW
DESCRIPTION
B p
JUNCTION BOX TYPE 1,2
O
)11��
ROADWAY LUMINAIRE POLE
UTILITY MOUNTED LUMINARE
UTILITY POLE
PEDESTRIAN LUMINAIRE POLE
— — —
CONDUIT/CONDUCTOR
®
ELECTRICAL SERVICE CABINET
OCONSTRUCTION
NOTE
O
LUMINAIRE POLE NUMBER
AWIRE
NOTE
1
1
1
1
-3.3' CENTER POLI
TO CENTER STORM
LINE
Z
10 40
0 20 60
SCALE IN FEET
G G —
1
w w
2
rZ
W
Z
— EX
=�IW w y EX R/W
G G GL —
G G G
� G G
N
05,
11f00
7 — —12f00 ss�ss o
6 1 N 2 w T— �— — lJ400 --
w w
7 w w A w
w w W ,.,
w
I
I
I
I
I V �
OI I
od N i
1 1+
7
I
1 � I
I
I I
2 1
I
ZT
4.8' CENTER POLE
TO CENTER STORM
LINE
L
r--
F
_J
REVISION
`-Q�--J
SURVEYED:
OTHERS
DESIGNED:
DAG TD
DRAWN:
DAG
CHECKED:
TOR KE!
BY DATE A P P R APPROVED:
CTB
OHP
6 EX R
rrli
�I
of
I
Z
a
0
co
O
It
N
ILLUMINATION CONSTRUCTION NOTES
OCONSTRUCT FOUNDATION PER CITY OF RENTON STANDARD DETAIL 116.1. FOUNDATION SIZE AND DEPTH SHALL BE DETERMINED PER
STRUCTURAL ANALYSIS. FURNISH AND INSTALL NEW NEIGHBORHOOD STREET PEDESTRIAN LUMINAIRE POLE, LUMINAIRE, AND JUNCTION BOX
PER ILLUMINATION POLE SCHEDULE, SHEET IL-02, AND PER CITY OF RENTON STD PLANS 116.1, 116.2, 119, 120 & J013. APPLY DECAL
NUMBERING WITH COR POLE ID PER THE ILLUMINATION POLE SCHEDULE AND CITY OF RENTON STANDARD DETAIL 121.
OCONSTRUCT FOUNDATION PER CITY OF RENTON STANDARD DETAIL 117.1. FOUNDATION SIZE AND DEPTH SHALL BE DETERMINED PER
STRUCTURAL ANALYSIS. FURNISH AND INSTALL NEW ARTERIAL STREET DECORATIVE LUMINAIRE POLE, TWO LUMINAIRES, AND JUNCTION BOX
PER ILLUMINATION POLE SCHEDULE, SHEET IL-02, AND PER CITY OF RENTON STD PLANS 117.1, 117.3, 119, 120 & J013. APPLY DECAL
NUMBERING WITH COR POLE ID PER THE ILLUMINATION POLE SCHEDULE AND CITY OF RENTON STANDARD DETAIL 121.
YCONSTRUCT SERVICE CABINET FOUNDATION PER CITY OF RENTON STD PLANS 126.1 & 126.2, SHEET IL-03. FOUNDATION SHALL BE
ADJACENT TO AND FLUSH WITH SIDEWALK. FURNISH AND INSTALL SERVICE CABINET PER CITY OF RENTON STD PLANS 122.1 & 122.2,
SHEET IL-03. LOCATION AND ORIENTATION OF FOUNDATION AND CABINET SHALL BE VERIFIED BY CITY OF RENTON INSPECTOR PRIOR TO
INSTALLATION OF CONDUITS.
OTHE POWER SOURCE LOCATION WAS NOT KNOWN AT THE TIME OF PLAN PREPARATION. THE CONTRACTOR SHALL COORDINATE WITH PSE TO
IDENTIFY A LOCATION FOR 1201240 VOLT SINGLE PHASE POWER SOURCE CONNECTION. THE CONTRACTOR SHALL COORDINATE WITH THE
OWNER FOR COMPLETION OF ALL NECESSARY FORMS/APPLICATIONS ASSOCIATED WITH THE NEW POWER SOURCE. THE CONTRACTOR SHALL
INSTALL CONDUIT AND CONDUCTORS TO THE POWER SOURCE. CONTRACTOR SHALL COODRINATE WITH PSE FOR SPECIFIC REQUIREMENTS. PSE
SHALL MAKE FINAL CONNECTION TO THE POWER SOURCE. THE CONTRACTOR SHALL ASSUME 500' OF TRENCHING TO CONNECT TO POWER
SOURCE FOR BIDDING PURPOSES.
OEXISTING TIMBER UTILITY POLE TO BE REMOVED OR RELOCATED. SEE CIVIL PLANS FOR ADDITIONAL DETAILS. CONTRACTOR SHALL
COORDINATE WITH PSE FOR THEM TO REMOVE EXISTING LUMINAIRE AND ARM.
O6 EXISTING UTILITY POLE MOUNTED LUMINAIRE TO REMAIN.
OCONSTRUCT FOUNDATION PER CITY OF RENTON STANDARD DETAIL 117.2. FOUNDATION SIZE AND DEPTH SHALL BE DETERMINED PER
STRUCTURAL ANALYSIS. FURNISH AND INSTALL NEW ARTERIAL STREET DECORATIVE LUMINAIRE POLE, LUMINAIRE, AND JUNCTION BOX PER
ILLUMINATION POLE SCHEDULE, SHEET IL-02, AND PER CITY OF RENTON STD PLANS 117.2, 117.3, 119, 120 & J013. APPLY DECAL
NUMBERING WITH COR POLE ID PER THE ILLUMINATION POLE SCHEDULE AND CITY OF RENTON STANDARD DETAIL 121.
T-430504
SCALE:
VERTICAL: NAVD 1988
HORIZONTAL: NAD 1983/1991 C T Y OF
RENTON
ONE INCH DATUM •
AT FULL SCALE Planning/Building/Public Works Dept.
IF NOT ONE INCH
SCALE ACCORDINGLY
PROJECT NO. TENW 2024-0 15
TREVIN ROLETTO, P.E.
TEN W SENIOR PROJECT MANAGER
ROLETTO@TENW.COM
425-250-0583
•�� 520 KIRKLAND WAY, SUITE 100, KIRKLAND, WA, 98033
�Mwwr+' V
0410212025
IN COMPLIANCE WITH CITY OF RENTON STANDARDS O
DEVELOPMENT ENGINEERING
HHuynh 04/17/2025
JONES RENTON SHORT PLA T
3102 PARlfAVEN, RENTON, WA 98056
ILL UM/NA T/ON PLAN
W
DATE:
04102125
FIE
PAGE: O
DRAWING/Lo01
SHEET: 23 OF:26