No preview available
HomeMy WebLinkAboutT-430507DocuSign Envelope ID; 9099OOAB-0385-4W4-AE66-578FF1561DTF T-O" DocuSign Envelope ID; FD9FD439-BD22.4654-ABD3-E560AAIF5959 -1 � a�D io 0 a Wa 0 r �- 1 MIN. MIN. LUMINAIRE POLE JUNCTION BOX LUMINAIRE POLE JUNCTION BOX CONCRETE PAD. CONCRETE SIDEWALK PLAN VIEW BROOM FINISH PLAN VIEW PER STD PLAN 102 LUMINAIRE POLE LUMINAIRE POLE RETE 'MEWALK CONCRETE PAD GPER STD PLAN 1102 4- JUNCTION BOX -Ll1hIINAIRE CONCRETE FOUNDATION SIDE VIEW LUMINAIRE CONCRETE PAD DETAIL GENERAL NOTES: t LUMINAIRE CONCRETE PAD SHALL BE USED IN AREAS OUTSIDE OF SIDEWALK 2. CONCRETE CLASS FOR LUMINAIRE CONCRETE PAC) SHALL BE PER STD PLAN 135 3- TOP OF LUMINAIRE FOUNDATION ELEVATION SHALL HE LOCATED AT BOTTOM OF LUMINAIRE CONCRETE PAD ELEVATION OR BOTTOM OF SIDEWALK ELEVATION 4, LUMINAIRE POLE AND JUNCTION BOX TYPE PER PLAN 5- LUMINAIRE CONCRETE PAD ACCOMMODATES TYPE 1 AND TYPE 2 JUNCTION BOXES ONLY PUBLIC WORKS DEPARTMENT ry i J JUNCTION BOX LUAIINAIRE CONCRETE FOUNDATION SIDE VIEW LUMINAIRE WiTI'I SIDEWALK DETAIL 1'-W CONCRETE PAD JUNCTION BOX J/ PLAN VIEW 4" CONCRETE PAD JUNCTION BOX SOE VIEW INDMDUAL JUNCTION BOX PAD DETAIL --•-----"-------''--- - - STD. PLAN - 120 PADISIDEWALK AND j ROVED: JUNCTION BOIL CONCRETE PAD, Ma~rU PwsWcha 7/27/2022 RATE DocuSign Envelope ID: FOOF0439-BU22-4654-ABD3-E560AA1F5959 CONIM)M.41 S(1111L )ELI.k I METERBASE: 200 AMP. 4 JAW, MANUAL BYPASS. B-LINE U264 W/ 5TEI JAW AT 9:00 POSITION PANIELBOARD: 1201240 VAC, 125 AM? COPPER BUS. I PHASE, 3 WIRE, 18 CKT, I OK AIC- MAIN BREAKER: 2()0 AMP FRAME., 200 AMP TRIP, 2 POLE, FATON E.D2200 BOLT -ON BRANCH BREAKERS, EATON TYPh BAW 2 - 20/2 ILLUMINATION A. B 1 -20/1 ITS 1 - 2011 GROUND FAULT RECEPTACLE 1 -40/1 SIGNAL(IF PRESENT) 1 -4011 AUX]LL]ARY SIGNAL (IF PRESENT) 2 - 60/2 SMALL CELL BRANCH 1 - 1511 CONTROL 3 - 2011 SPARE CONTACTOR: NEMA LIGHTING RATED, 30 AIMP4 POLE, 120 VAC C011.., SQD 8910DPA34V02-1 REQUIRED PHOTO ELECTRIC CELL: 1800 WATT, 120 VAC. TWIST LOCK. ALR #8ST-IE5-UL MUUNTFD INSIDE (:ABINEI T BEHIND W1REQLASS WINI)DW 50 PII070-CELL BYPASS SWITCH: SPLIT, 15 AMP. RATED (UP TO) 277 VAC [FED THROUGH TERMINAL BLOCK) GROUND FAULT RECEPTACLE:20 AMP, 1.25 VAC, DUPLEX CABINET: CONSTRUCTION: NEIVIATYPE 3R, OUTDOOR PADMOUNT, I/8"5052-H32 ALUMINLIM CONSTRUCTION, OPEN BOTTOM FRAMED WITH 2" ANGLE. 2 SCREENED AND CIASKETED VENTS, REMOVABLE EQUIPMENT MOUNTING PAN, CABINET GROUND WITH MINIMUM BONDINU WIRE TO NEUTRAL DOORS: HEAVY-DUTY CONCEALED ]TINGES (LIFT-OFF TYP£),STAINLESS STEEL VAULT IIA1NDLES WITH ROLLER RODS THAT PROVTDF 3-POINT COMPRFSS[ON ON CLOSED CELL NF.OPRENF GASKET, "BEST" LOCK ON LOWER DISTRIBUTION DOOR WITH CARD HOLDER, PADLOCKABLE UPPER METER DOOR WITH POLISHED SAFETY GLASS WINDOW DEAE)1 RONT: HINGED AND SECURED WITII QUARTER -TURN FASTENERS FINISH: MILL FINISH ALUMINUM 1 -REQUIRED UL LISTED PER STANDARD #508A "SUITABLE FOR USE. AS SERVICE ENTRANCE•" NOTE: 1. SIGNAL BREAKER(S) SHALL BE ADDED WHEN APPLICABLE 1.` PUBLIC WORKS 4 I� DEPARTMENT �S SERVICE CABINET NOTES PLAN - 122.2 aStucwg/20Z1 14 3: DDcuSign Envelope ID:9D9BODAB-0385-4664-AEfifi-578FF1551D7F INSTALL DECAL NUMBERS/LETTERS VERTICALLY. DECAL NUMBERS/LETTER5, SEE NUMBERING EXAMPLE, THIS SHEET. SHALL BE INSTALLED IN DRY WEATHER. 50' F OR ABOVE E E 4 C 5 s fi z 7 z 0 NUMBERING Dum" i.E YOIINifiOIEIOFfi GLiAE 1-3/4' TO 2" �PEDESTRIAN SCALE CURB DECAL TRAFFIC OlP�1L GRI�ifAilg[1 FOR POLES C11OM M III PLM 11HL1 P[7 PEDESTRIAN SCALE DECAL i �P£DESTRIAI3 SCALE FCURS DECAL T FLOW FLOW DECAL ORIENTATHDN FOR POLES SHOWN ON STD PLAN 1172 TRAfFlC fL01V T1WAL ORRNTATiON Fm POLESSNOm ON STO PLAN 11T1311T.11A o.aa' z RINWAY11rJY,EOM& PEDESTM SCALE #LEGAL DECAL -NO I. DECALS SHALL BE REFLECTORIZED, GOTHIC FONT, GOLD OR WHITE LEGEND ON BLACK BACKGROUND SCALE CALE LUMINAIRE STANDARD DECAL STD. PLAN - 121 PUBLIC WORKS NUMOEMNO SYSTEM APPROVED: 17 DEPARTMENT 7/27/2022 I FRanin Paswcrw - DATE DDcuSign ETrmlcpe ID: 9D9BODAB-0385.4664-AE66-578FF1581D7F CONDUIT ENTRANCE AREA, SEE NOTE 13, STD PLAN 126.2 a • G Ora i SEE STD PLAN 126.2 FOR ADDITIONAL NOTES . d • ; c PLAN VIEW SIZE. T4 FIT SIZE TO FIT CABINET ABINET fi" fi" 1'-4" �I -GRADE LEVEL C14L ------- + • •d � FRONT VIEW SIDE VIEW ELECTRICAL SERVICE CABINET FOUNDATION SEE STD PLAN 126.2 FOR ADDITIONAL NOTES SHIM TO PLUMB SEE NOTE 3 0 4 HOOPS 4 BAR E�AC-i CORNER 6- MIN 1 TO 2° 3/8" DIAMETER PLASTIC DRAIN SIDE VIEW CABINET DEPTH 1'-6" + 2 1'-6" t� I in - - - �� ` - #4 BAR EACH N #4 CORNER Lu } p HOOPS -4 IIWLJ I 1111 PLAN VIEW CONDUIT ENTRANCE AREA, SEE NOTE 5, STD PLAN 126.2 CONTROLLER CABINET FOUNDATION CABINET FOUNDATION STD. PLAN - 126.1 PUBLIC WORKS DETAILS DEPARTMENT APPROVED: 7127/2022 1 Man1n Psstuchs DATE Lij w NO. REVISION L, z Lu LS � I1(FII���I�IIf��I1/]l 111�,y,{fI r6T 4 y 1^ O z �... 0 IIIIIIIIIIIIII > [V r i Jcv W , � � e w LUW zLLI LLjW❑� Ind �Z 0�> w Lu F- > m�= ❑- Uu13: Lin >U ❑Q�U Lu itO< 2 �} z z W_ W W Of m 2 LL1--w 0 WM LL OWF-ce W Lmu (S u l oaH¢O J z= W he C7D2mw z z W c4�t7m lY U LA! ❑uj IL mad o 1W 2 WD Wzrzz W(1]� in 0 d Lu 2z W � LIJ Lu F- F- W Q z �j �TWU Q m o = o= = LLI u�F N ? O 0 2 � I-- IAI a LL U � � {y CV r. r i I z QL ❑ 10 W z UJ cn W In 4 2 EL w 0 z 0 7 a v 0 N SERVICE CABINET Pa LAN - 122.1 PUBLIC WORTHS �P DEPARTMENT M1 a n �stuc?M$/2021 14 DATE DocuSign Emelope ID: 9D9BODAB-0385.4664-AE66-57BFF15BID7F NOTES 1, WHERE FOUNCATION PAD 1S LOCATED WITHIN A SIDEWALK. CONSTRUCT PAD TOP FLUSH INITH SIDEWALK GRADE. OWTTING CHAMFER WERE Trip AW SIDEWALK ABUT. MOUNT TOP SHALL BE FINISHED BY A CONCRETE CONTRACTOR AND SHALL MEET THE REQUIREMENTS OF SECTION 5-14.3 IN THE WSDDT STANDARD SPECIFFCATIONS, 2. PAD MOUNT DESIGN IS TYPICAL. 3. PLACE A SILICONE SEAL BETWEEN THE FOUNDATION AND CABINET. 4. ANCHOR BOLTS AND THEIR SPACING TO BE SUPPUED BY CABINET MANUFACTURER AND SUBMITTED TO ME ENGINEER FOR APPRDVAL. 5. CONDUIT SIZES/QUANTITIES FOR CONTROLLER CABFNETS SHALL BE INSTALLED PER THE CONT1ACT PLANS, PLUS ONE 2- SPARE CAPPED OUT PAST TH1' FOUNDATION. B- =14CRETE CLASS PER STD PLAN 135- ELECTRICAL SERNCr=/99S CABINET 7- 2- CONOUT SHALL BE PLACED FROM THE ELECTRICAL SERVICE/BBS CABINET TO THE CONTROLLER CABINET. B. EACH CABINET SHALL HAVE A %- DIAMETER PLASTIC DRAIN PIPE. CONTROLLER CABINET SHIM To PLUMB :�\SEE HOLE 3 ij 3 - j4 REINFORCING BAR (EQUAL SPACES) SEE NOTE 5 - `n + -- m UV 9. LOCATE CONDUITS CENTRALLY WITHIN THE CAD[NE7S. lD. AEON ALL TOMB cABR OUN ATE TO DE I HE USED AND SPACE ALLOWS, A COMBINED FOUNDAT18N SHALL BE USFT]. 11. M30DEN SHIMS SHALL N-OT BE USED 12. GROUNDWG SHALL RE PER WSDOT STANDARD PUN .!-SD.OS, SHEET 3. IS. CONDUIT SZES/OUANITTIES FOR ELECTRICAL SERVICE CABINETS SHALL SHIM TO PLUMB BE INSTALLED PR THE CONTRACT PUNS, PLUS ONE 2- SPARE CAPPED OUT PAST THE FOUNDATION. SEE NOTE 3 4 HOOPS SHIM TO PLUMB (EQUAL SPACES) SEE NOTE 3 1191I �2' II�VI . II I- TD 2- FT•iON1T VIEW 3/6' DIANCTER PLASTIC DRMN COME PER CABINET] SEE NOTE 7 31W DIAMETER PLASTIC DRAIN �_ SEE NOTE 13 3 - 14 REINFORCING BAR (EQUAL SPACES) PLAN VIEW CABINET FOUNDATION 4 I� PUBLIC WORKS DETAILS 7.: DEPARTMENT SURVEYED: OTHERS DESIGNED: DAG TD DRAWN: DAG CHECKED: TOR KE! BY DATE APPR APPROVED: CTB r-a- HDRI2DNTAL COMBINED FOUNDATION REINF_ BAR DIAGRAM 6 PIECES STD. PLAN - 126.2 APPROVED: ManinPa6Tucha 7I27/2Ha22 i1.ATE 31 T-430507 SCALE: VERTICAL: NAVD 1988 • C T Y O E HORIZONTAL: NAD 1983/183/1991 RENTON ONE INCH DATUM AT FULL SCALE Planning/Building/Public Works Dept. IF NOT ONE INCH SCALE ACCORDINGLY O co O N No fir. 1 /4" LOAD FUSE LINE 1 /4" 1/8" QO O 1/8" CUTTING RINGS FUSE KIT rnr)vv CII I VVTL Jt'Llk t SPLICE KIT FUSE KIT & SPLICE KIT DETAILS G1�Y O� ADOPTED CITY OF RENTON STANDARD PLANS O� LET DATE:04/04 _� I .�,..... nwr. NAAAF, .Inn 3 CP PA ]F• .I(11 3 PROJECT NO. TENW 2024-0 15 TREVIN ROLETTO, P.E. MI�T SENIOR PROJECT MANAGER JL adROLETTO@TENW.COM Ermw425-250-0583 520 KIRKLAND WAY, SUITE 100, KIRKLAND, WA, 98033 N102/202L5 IN COMPLIANCE WITH CITY OF RENTON STANDARDS O DEVELOPMENT ENGINEERING rij HHuynh 04/17/2025 JONES RENTON SHORT PLA T 3102 PAR/fAVEN, RENTON, WA 98056 ILL UM/NA T/ON PLAN DETAILS O DATE: 04102125 FIE PAGE: O DRAWING C O4 s SHEET: OF: 26 26