Press Alt + R to read the document text or Alt + P to download or print.
This document contains no pages.
HomeMy WebLinkAboutT-430508Lo
0
Nt
T
Nt
O
rr
F__
z
w
EX R/W II
co
u
EX R/W
(�--�---� --- - EX R/W
y -
�+ F-`* F-`* F-`* F-`* I-`* �+ + �+ �+ �+ �+ �+ �+ �+ O+ O+ O+ p+ p+ p+ �- - - 9f 00 A U n 6 O T O O m (' A cl AA :W N N+ O 0 O O
J J J J-�--�- a,-- �_ o W 12700
PARK AVE N �+ * N+ N+ N+ '+ N+ �I'* . * . . . * + + _+ �+ �+ O+ O+ O+ O+ T W W+ -�+ - t_
to l0 O
Al N+ N* N* N* N* N* N* N F-`* N* N F-`* N* N* N+ �+ �+ �+ �+
~ O O CD CD O O O O l0 O O p Qp+Ol+ J J J Ol J J
N+ N+ ,V+ N+ F'+ + F'+ I-' N+ N+ N+ N N+ N N+ I-`+ I-'+ I-'+ �+ p+ F-`+ Imo*'�
W ~ ~ ~ ~ N O O OJ Ol �P N O O lD O CD CD CDF-` F-` W X.
J �+ �
EX R/W ®� 00 � c M CDW N -_
�+
.o m w/`•" W N+
z
N
4
co
I
EX R/W
�+
EXISTING UTILITY POLE MOUNTED LIGHT 4 N w i EX R/W
HEIGHT = 34' EX
LAMP = 39W LED EX J`
INITIAL LUMENS = 5,000 EX o �• 6
FIXTURE = GE ERL1 EX C •• N ,
DISTRIBUTION = TYPE
LLF = 0.80 EX14
--+--
� I
;
3
;
I I
I
o o!
••
o I oa N
1+! I
• • cid
. o 7
;
I
1
N* ® O
,
1
0-
J l0 N I
p+ p . . ROAD 8 '
I
w co co
p*c p+ -
1
Ll m - - --
p* O*ED
p* p* p*
�- - -
I
I
I
O
1
• I
I
W CD�---
o ,
1
;
_J I
, I
I I
DATE: 04/02/2025
ILLUMINATION LEGEND
EX
NEW
DESCRIPTION
O�
ROADWAY LUMINAIRE POLE
UTILITY MOUNTED LUMINARE
UTILITY POLE
PEDESTRIAN LUMINAIRE POLE
OLUMINAIRE
POLE NUMBER
kJ7
I
0
TARGET
CALCULATION SUMMARY
ACTUAL
CALCULATION
AREA
MIN. AVG.
MAX.
MIN.
MAINTAINED
UNIFORMITY
FOOT CANDLES
FOOT CANDLES
RATIO
PARK AVE N
0.90
4:00:1
N/A
(MINOR ARTERIAL)
1.38
1.73:1
0.80
PARK AVE AND ROAD A
1.20
4.00.1
N/A
(INTERSECTION -
COLLECTOR)
1.67
1.52: 1
1.10
ROAD A AND ROAD B
0.80
6.00:1
N/A
(INTERSECTION -
RESIDENTIAL)
0.94
4.70:1
0.20
PARK AVE N
N/A
6.00:1
0.30
(SIDEWALK - LOW PED
ACTIVITY)
2.59
2.59:1
1.00
ROAD A
(SIDEWALK -
0.30
6.00:1
0.30
RESIDENTIAL)
10.68
3.40:1
0.20
* MINIMUM FOOT CANDLE LIGHT LEVEL ACCEPTED BY CHRIS BARNES
IN EMAIL DATED 1112712024 FROM HUY HUYNH WITH THE CITY
OF RENTON.
EXISTING UTILITY POLE MOUNTED LIGHT
HEIGHT = 25' EX
LAMP = 53W LED EX
INITIAL LUMENS = 5,600 EX
FIXTURE = GE ERL 1 EX
DISTRIBUTION = TYPE III
LLF = 0.80 EX
ILLUMINATION POLE SCHEDULE
LUM.
POLE ID
POLE
MOUNT.
ARM
WATTAGE
INITIAL
LUMINAIRE TYPE -
POLE NO.
NUMBER***
STREET
STATION *OFFSET
*
LATITUDE **
LONGITUDE **
HEIGHT
HEIGHT
LENGTH
VOLTAGESERVICE/
CIRCUIT
/TYPE
LUMENS
DISTRIBUTION
BASE
COMMENT
O
ROAD A
6+83.5
18.0' RT
14'
16'
N/A
240
ILUM A
40W LED
4,200
CYCLONE PRESTIGE
FIXED
NEW FOUNDATION AND POLE PER RENTON
CY17T4-VS3AR-T3-P30-40K-240-10KV-EA 1
STD PLAN 116.1. ****
O2
ROAD A
6+ 14.5
18.0' LT
14'
16'
N/A
240
ILUM A
40W LED
4,200
CYCLONE PRESTIGE
FIXED
NEW FOUNDATION AND POLE PER RENTON
CY1 7T4-VS3AR-T3-P30-40K-240- 1 0KV-EA 1
STD PLAN 116.1. ****
O3
ROAD A
5+74.0
17.5' RT
14'
16'
N/A
240
ILUM A
40W LED
4,200
CYCLONE PRESTIGE
FIXED
NEW FOUNDATION AND POLE PER RENTON
CY1 7T4-VS3AR-T3-P30-40K-240- 1 0KV-EA 1
STD PLAN 116.1. ****
35.5'
6'
110W LED
11,421
CYCLONE DOMIA
G
PARK ROAD N
9+62.0
23.5' RT
40'
240
ILUM B
CY55P 1 A-FGC-T3-P70-40K-240-EA 1
FIXED
NEW FOUNDATION AND POLE PER RENTON
****
16.5'
4'
35W LED
4,159
CYCLONE DOMIA
STD PLAN 117.1.
CY55P1A-FGC-T3-P20-40K-240-EA1
35.5'
6'
110W LED
11,421
CYCLONE DOMIA
OS
PARK ROAD N
10+37.0
23.5' RT
40'
240
ILUM B
CY55P 1 A-FGC-T3-P70-40K-240-EA 1
FIXED
NEW FOUNDATION AND POLE PER RENTON
****
16.5'
4'
35W LED
41159
CYCLONE DOMIA
STD PLAN 1 17.1.
CY55P1A-FGC-T3-P20-40K-240-EA1
O
PARK ROAD N
1 1 +02.0
23.5' RT
20'
16.5'
2'
240
ILUM B
35W LED
4,159
CYCLONE DOMIA
FIXED
NEW FOUNDATION AND POLE PER RENTON
CY55P 1 A-FGC-T3-P20-40K-240-EA 1
STD PLAN 117.2. ****
35.5'
6'
11OW LED
11,421
CYCLONE DOMIA
7
O
PARK ROAD N
1 1 +58.0
23.5' RT
40'
240
ILUM B
CY55P 1 A-FGC-T3-P70-40K-240-EA 1
FIXED
NEW FOUNDATION AND POLE PER RENTON
****
16.5'
4'
35W LED
4,159
CYCLONE DOMIA
STD PLAN 117.1.
CY55P1A-FGC-T3-P20-40K-240-EA1
0 40
SCALE IN FEET
* STATIONS/OFFSETS ARE APPROXIMATE. CONTRACTOR SHALL CONFIRM ADJUSTMENTS WITH CITY INSPECTOR PRIOR TO IMPLEMENTING.
** POLE LATITUDE AND LONGITUDE NUMBERS SHALL BE PROVIDED BY CONTRACTOR FOR INCORPORATION INTO AS -BUILT PLANS.
*** POLE ID NUMBERS SHALL BE PROVIDED BY ERIC CUTSHALL (CITY OF RENTON, 425-430-7423) FOR INCORPORATION INTO AS -BUILT PLANS AND INSTALLED BY THE CONTRACTOR IN ACCORDANCE WITH CITY OF RENTON STANDARD PLAN 121.
**** FOUNDATION SIZE AND DEPTH SHALL BE DETERMINED PER STRUCTURAL ANALYSIS. LATERAL BEARING PRESSURE WILL NEED TO BE PROVIDED TO THE STRUCTURAL ENGINEER, TYPICALLY BY A GEOTECHNICAL ENGINEER.
` SHEET
EN JONES RENTON SHORT PLAT
1
` ' 520 KI RKLAN D WAY, SUITE 100,
NKI RKLAN D, WA, 98033 OF
TREVIN TP.E. PHOTOMETRIC CALCULATIONS
SENIOR PROJECT MANAGER 1
ROLETTO@TENW.COM
425-250-0583
T-430508