SIX EVENLY SPACED
HOLES ON 10 3/8" BOLT
IRCLE FOR BOLTING TO
FLANGE CONNECTION. W
Lu
2
J
------- -�------------- --- --�--- -
®/ ®
---- - ------ - - --- IT ---
SEE NOTE 5
LEVEL LINE
-- - - -� - - - - -- -------
FRONT SIDE MAXIMUM OPENING OF GATE
HANDLE WITH LOCK PIN.
0
ADJUSTABLE LOCK HOOK WITH LOCK SCREW.
O
LIFT HANDLE SHALL BE ATTACHED PER
fl J� 1' ROD OR TUBING, VARIABLE LENGTH. MANUFACTURER'S RECOMMENDATIONS.
LIFT HANDLE
NOTES:
1. SHEAR GATE SHALL BE ALUMINUM ALLOY PER ASTM B-26-ZG-32a OR CAST IRON ASTM A48 CLASS 30B AS REQUIRED.
2. GATE SHALL BE 8 IN. DIAM. UNLESS OTHERWISE SPECIFIED.
3. GATE SHALL BE JOINED TO TEE SECTION BY BOLTING (THROUGH FLANGE), WELDING, OR OTHER SECURE MEANS.
4. LIFT ROD: AS SPECIFIED BY MFR. WITH HANDLE EXTENDING TO WITHIN ONE FOOT OF COVER AND ADJUSTABLE HOOK LOCK
FASTENED TO FRAME OR UPPER HANDHOLD.
5. GATE SHALL NOT OPEN BEYOND THE CLEAR OPENING BY LIMITED HINGE MOVEMENT, STOP TAB, OR SOME OTHER DEVICE.
6. NEOPRENE RUBBER GASKET REQUIRED BETWEEN RISER MOUNTING FLANGE AND GATE FLANGE.
7. MATING SURFACES OF LID AND BODY TO BE MACHINED FOR PROPER FIT.
8. FLANGE MOUNTING BOLTS SHALL BE 3/8 IN. DIAM. STAINLESS STEEL.
9. ALTERNATE CLEANOUT/SHEAR GATES TO THE DESIGN SHOWN ARE ACCEPTABLE, PROVIDED THEY MEET THE MATERIAL
SPECIFICATIONS ABOVE AND HAVE A SIX BOLT, 10 3/8 IN. BOLT CIRCLE FOR BOLTING TO THE FLANGE CONNECTION.
Y STD. PLAN - 237.30
PUBLIC WORKS FROP - T - SHEAR GATE DETAIL
DEPARTMENT
1v1ARC11:2008
SEC. 0 Q T, 23 N, , R. 05 E, , W. M.
(SEE CONTRACT)
ROU DING 2 0'• �1� 1Q- IIN) R. (TYP.)
I CURB NOT INCLUDED IN BID ITEM -
= 15% `
SEE RAISED EDGE 18' (NI PREMOLDED '•'�•
V-0- SIDEWALK DETAIL - THIS SHEET JOINT FILLER
ALL CUT MIN. (SEE CONTRACTI
SLOPES
1R• UN) R. (TYP.) WITH RAISED EDGE
Q �URB NOT INCLUDED IN SIO ITEM -
R'
31B• (INI PREMOLDED FINISHED GRADE 1' (N) BELOW
JOINT FILLER'TOP OF CONCRETE SURFACE
2'-0• SIDEWALK
ADJACENT TO CURB i' 0' 1'-0' MIN. (SEE CONTRACT)
ROU DING 1f2" (IN) R. (TYP.)
�2.0% 1: _ 1 5% _ CURB NOT INCLUDED 1N BID ITEM -
318.
BRIDGE OR PEDESTRIAN PREMOLDED WALL OR BARRIER
RAILING JOINT FILLER
ADJACENT TO CURB
BARRIER - SEE SIDEWALK (STEEP Ff.L SLOPES)
CONTRACT PLANS (SEE CONTRACT) WALL OR BARRIER
14" (IN) R. (TYP.)
SIDEWALK
FLUS-1 - 1 5% CURB NOT INCLUDED IN BIO ITEM -
:s ., ►.. y rr 112' (1 1 R.
• • : Z'
VERTICAL WALL - 3r8' (IN) PREMOLDED ' �� • . .-r1
SEE DETAIL JOINT FILLER ITYP.) • !
ADJACENT TO CURB AND RAILING OR WALL 3+8' (INI PREMOLDED
JOINT FILLER
SIDEWALK BUFFER STRIP
(SEE CONTRACT) (BEE NOTE 10)
12" (IN) R. SIDEWALK ADJACENT TO WALL DETAIL
I IV 1 59L (TYP.) CURB NOT INCLUDED IN BID ITEM -
1 MIN 6'
s+++-:1'+aS•�" 1,LEVEL _,.J
�• •� 1-'2" IINI R.
FINISHED GRADE V (IN) BELOW TOP OF CONCRETE
SURFACE FOR PLANTING - FLUSH IF PAVED v
ADJACENT TO BUFFER STRIP ,}'' �+ m t IIN) R ! ►.•.
G BROO1.tED FINISH • �• ° �
4' WIDE, SMOOTH
O, q."d I'.� TROWELED PERIMETER RAISED EDGE DETAIL
EXTENfZ O' SIDEWALK TRANSVERSE
JOINTS DTO INCLUDE RAISED EDGE
CEMENT CONCRETE CURB
(CURB AND GUTTER SHOWNI
�" NOT INCLUDED IN BID ITEM
. _. �,�.,.�, ��.�.� tea.. -
,`'�.: For NOTES see STD PLAN 104.2.
Paved surfaces must Comply with
STD PLAN 102.1 as applicable.
316" LL IW T��O IA
CONTRACTION JOINT
00,-, ` IN SIDEWALK ONLY
EXPANSION JOINT IN BOTH ,'�•,• 0 •�• �•�•�,?�'l0 •�,
CURB AND SIDEWALK ! SEE STD PLAN 101 1PREMLDED
.
JOINT AND FINISH
DETAIL DINT P LLER
E' EXPANSION JOINT J CONTRACTION JOINT
Q
PUBLIC WORKS CEMENT CONCRETE STD. PLAN - 102
DEPARTMENT SIDEWALK PPRO 'Ell:
i
6-IN WIDE CONCRETE BAND
BETWEEN PERMEABLE SIDEWALK
AND LANDSCAPING STRIP
SIDEWALK VARIES PLANTER VARIES
12-FT TO 21.5-FT 9-FT TO 0-FT
2% MAX
. . a
I : LANDSCAPING TO BE LANDING
ri'�7 \ �Tr�i�rj�i��r\ DEPRESSED 1-IN BELOW
CONSTRUCTION GEOTEXTILE FOR ,\ \\i i,.i�>\i i\\i\\i\\i\\i\\i\\i\�i�\\i,\7i\\i\\i\\i\\i��
UNDERGROUND DRAINAGE, CLASS A !� ��\\�\,���j;\�\!/`��\��\����`� CONCRETE BAND GRADE BREAK -
UNDERGROUND �
MODERATE SURVIVABILITY PER NOTE 4
COMPACTED SUITABLE BASE SEE SUNSET BLVD. PLANS BY COR
MATERIAL AS NOTE 1 4' - 0" MIN.
6-IN MIN AGGREGATE BASE WITH A CEMENT CONCRETE
LEVEL BOTTOM. AGGREGATE BASE SHALL SIDEWALK
BE OPEN GRADED MATERIAL 3/4-IN TO
2-IN, CRUSHED AND WASHED
5-IN PERVIOUS CEMENT CONCRETE
SEE NOTE 5
N OTES
1. THE SUBGRADE SHOULD BE COMPACTED TO 90 TO 92 PERCENT STANDARD
COMPACTION OR AS APPROVED BY THE ENGINEER.
2. INSPECTION REQUIRED FOR FORMS AND SUB GRADE APPROVAL BEFORE POURING
CONCRETE.
3. MATCH JOINTS ON SIDEWALK WITH JOINTS ON THE CURB AND GUTTER AT 10' O.C.
4. APPLY SEPARATION GEOTEXTILE ON SIDES. EXTEND GEOTEXTILE ABOVE PERVIOUS
CONCRETE SIDEWALK. AFTER PAVEMENT HAS CURED AND ADJACENT FINISHED
GRADE HAS BEEN STABILIZED, TRIM SEPARATION GEOTEXTILE TO FINISHED GRADE.
5. PERVIOUS CONCRETE SIDEWALK SHALL BE PER CITY OF SEATTLE 2017 STANDARD
SPECIFICATION FOR ROAD, BRIDGE, AND MUNICIPAL CONSTRUCTION, SECTIONS
2-09.3(6), 4-04.3(5)B, 4-04.3(8)B, 5-06, AND 9-23.11.
PERVIOUS CONCRETE SIDEWALK DETAIL
CONSTRUCTION RECORD DRAWING
THIS CONSTRUCTION RECORD DRAWING IS A COPY OF
THE APPROVED CONSTRUCTION DRAWING PREPARED
BY OSBORN CONSULTING INC. AND HAS BEEN EDITED
USING INFORMATION PROVIDED BY OAK HILLS
CONSTRUCTION, LLC TO REFLECT ASBUILT CONDITIONS
N.T.S.
FLARE (TYP.)
3/8" EXPANSION
JOINT (TYP.) N SEE
STANDARD PLAN F-30.10
GRADE BREAK -
CURB, OR CURBS
AND GUTTER N
SEE NOTE 4
FACE OF CURB
MEASURED PARALLEL
TO CURB (TYP.)
Gregg Zimmerman, Public Works Administrator
1/2"X4" EXPANSION MATERIAL
1/4"R AT JOINTS
SCORE LINES TO BE RADIAL
TO CURB AND GUTTER A i
+ W
1/2"X4" EXPANSION MATERIAL
1/4"R AT JOINTS
1/4"/FT. SLOPE
1/2"R
4" 1
GENERAL NOTES
"W"-WIDTH OF SIDEWALK
1/2"X5" EXPANSION
MATERIAL CURB RETURN
ONLY
1/2"X4" EXPANSION MATERIAL CEM. CONC. CURB AND GUTTER
1/4"R AT JOINTS
SCORE LINES
B
W
B
1/2"R 1/4"/FT. SLOPE
4" 1 /2"R
PAVEMENT AS PER PLANS
IlEEEEE
PAVEMENT AS PER PLANS
STANDARD CEM. CONC. PARKWAY STANDARD CEM.
CURB AND GUTTER CONC. CURB AND
GUTTER
SECTION A -A SECTION B-B
SEE SHEET 2.5.1 FOR ROADWAY DEVELOPMENT STANDARDS
JOINTS: DUMMY JOINTS SHALL BE PLACED NOT TO EXCEED 15' C/C NOR LESS THAN 10' C/C. THEY SHALL
NOT BE LESS THAN 3/16" IN THICKNESS AND SHALL BE EXTENDED 2" BELOW THE GUTTER LINE. 1/2"
THRU JOINTS SHALL BE PLACED AT ALL COLD JOINTS AS DIRECTED BY ENGINEER AND SHALL EXTEND 1"
BELOW CONCRETE.
WHERE THE SIDEWALK IS TO BE PLACED AGAINST THE CURB AND GUTTER, THE JOINT SHALL BE A COLD
JOINT. 1/2"X 5" EXPANSION MATERIAL SHALL BE PLACED FROM P.C.'S TO P.T.'S AT ALL CURB RETURNS.
1/2"X4" EXPANSION MATERIAL SHALL BE PLACED AT EVERY FOURTH SIDEWALK PANEL.
THE CONCRETE MIX FOR SIDEWALKS SHALL CONFORM TO THE REQUIREMENTS OF CLASS B (3/4") WITH AIR
ENTRAINMENT.
THE CONCRETE SHALL HAVE A BROOM FINISH WITH ALL EDGES HAVING A 2 1/2" TOOLED FINISH
SUBGRADE COMPACTION SHALL BE 90% (MODIFIED PROCTOR).
LEGEN D
A SLOPE IN EITHER DIRECTION
CURB RAMP WIDTH 4' - 0"
MIN. LANDING TO MATCH * 1.5 OR FLATTER RECOMMENDED FOR
DESIGN/FORMWORK (2% MAX.)
* * 7.5% OR FLATTER RECOMMENDED FOR
TYPICAL SIDEWALK
(JtiSy
ADOPTED
CITY OF RENTON
♦ I♦
STANDARD PLANS
�N TO
IST DATE: 04/04
DWG. NAME:
F007 SP PAGE: F007
removable watertight
coupling or flange
2" min.
max.
'I /
plate welded to elbow J/
with orifice as specified
ELBOW
RESTRICTOR
elevation per plans
1' min. under
pavement 16" max.
9" min.
design W.S.
elbow restrictor, see detail
pipe supports
see Note 6
1.5x D
min. I
2' min. -
T
T T dutlet pipe
D see notes 1 8
� 1
invert and elevation
E
per plans
(V 12"
12"
o
E
welded restrictor plate
N 12"
with orifice diameter as
specified (not needed if
for spill control only)
2' min. clearance
to any portion of frop-T
including elbows
NOTES: A
1.
2. Outl ity: 100-Year developed
peak flow.
3. Metal Parts: Corrosion resistant.
elbow restrictor
Non -Galvanized parts perferred. see detail
Galvanized pipe parts to have asphalt
treatment 1.
4. Frame and ladder or steps offset so:
A. Cleanout gate is visible from top.
B. Climb -down space is clear of riser and
cleanout gate.
C. Frame is clear of curb.
5. If metal outlet pipe connects to cement
concrete pipe: outlet pipe to have smooth
O.D. equal to concrete pipe I.D. less 1t-4".
6. Provide at least one 3" X .090 gage support bracket anchored to concrete wall.
(maximum T-0" vertical spacing)
7. Locate elbow restrictor(s) as necessary to provide minimum clearance as shown.
8. Locate additional ladder rungs in structures used as access to tanks and vaults to
allow access when catch basin is filled with water.
1 angle as
necessary
see note 7
T min.
PLAN VIEW
frame & solid cover
marked "DRAIN" with locking bolts
see note 3
I inlet
vertical bar
grate for
secondary inlet
handholds, steps or
ladder
shear gate with control
rod for cleanout/drain
(rod bent as required
for vertical alignment
with cover)
A
addtional ladder rungs
(in sets) to allow access
to tanks or vaults when
catch is filled with water
'tY
o�� PUBLIC WORKS FLOW RESTRICTOR STD. PLAN - 237.00
\I J DEPARTMENT OIL POLLUTION CONTROL
INO MARCH 2O08
TTEE
CONTRACTION JOINT (TYP.) N SEE WSDOT STANDARD PLAN F-30.10
O FOR CURB RAMP LENGTHS GREATER THAN 8' - 0" PROVIDE
CONTRACTION JOINT EQUALLY SPACED 4' - 0" MIN. O.C.
DESIGN/FORMWORK (8.3% MAX.) 4' - 0" MIN. 15' - 0" MAX. (TYP.)DETECTABLE WARNING SURFACE
GRADE BREAK 9.5% OR FLATTER RECOMMENDED FOR SEE SUNSET BLVD PLANS BY COR SEE NOTE 7 SEE WSDOT STANDARD PLAN F-45.10
SEE SUNSET BLVD. PLANS BY COR * * * DESIGN/FORMWORK (10% MAX.)
0" MIN. GRADE BREAK
* GRADE BREAK COUNTER SLOPE
PROVIDE SMOOTH TRANSITION COU
* * COU �MAX. TO SIDEWALK WIDTH (TYP.)
CURB RAMP
�i ............:::. i�
CROSSWALK
PLAN VIEW
GRADE
BREAK
a°
TOP OF ROADWAY
NOTES LANDING ` ° -•
1. AT MARKED CROSSWALKS, THE CONNECTION BETWEEN CURB RAMP
THE CURB RAMP AND THE ROADWAY MUST BE
CONTAINED WITHIN THE WIDTH OF THE CROSSWALK /�
MARKINGS. SECTION {� 1 DEPRESSED CURB AND GUTTER N ,
SEE WSDOT STANDARD PLAN F-10.12 '
2. WHERE "GRADE BREAK" IS CALLED OUT, THE ENTIRE
LENGTH OF THE GRADE BREAK BETWEEN THE TWO
ADJACENT SURFACE PLANES SHALL BE FLUSH.
3. DO NOT PLACE GRATINGS, JUNCTION BOXES, ACCESS
COVERS OR OTHER APPURTENANCES ON ANY PART
- OF THE,
CURB RAMP OR LANDING, OR IN FRONT OF
THE CURB RAMP WHERE IT CONNECTS TO THE
ROADWAY.
-DETECTABLE WARNING SURFACE -
SEE WSDOT STANDARD PLAN F-45.10 4. SEE SUNSET BLVD PLANS BY COR FOR THE CURB
DEPRESSED CURB AND GUTTER DESIGN SPECIFIED. SEE STANDARD PLAN F-10.12 FOR
SEE NOTE 4 CURB, CURB AND GUTTER, DEPRESSED CURB AND
GUTTER, AND PEDESTRIAN CURB DETAILS.
5. CURB RAMPS AND LANDINGS SHALL RECEIVE A BROOM
FINISH. SEE WSDOT STANDARD SPECIFICATIONS 8-14.
Know what's below.
Call before you dig.
m x
�o a9so v
PERPENDICULAR CURB RAMPI,.,
N.T.S.
R-400312