Loading...
HomeMy WebLinkAboutR-431517LO TMM C'J I 0 I 0 LW I a J J 4 73 w 2" MAX. 2x2 PINE TREE STAKES SET STAKES PERPENDICULAR TO PREVAILING WIND _ INSTALL "TREE BOOT" OR LU X "ARBORCxARD" IN LAWN AREA5. PLANT TREE P-2" HIGHER THAN IN NURSERY WATERING BASIN AMEND NATIVE 501L W/ I DEPTH 3-WAY MIX PRUNE DISEASED AND BROKEN BRANCHES CHAINLOCK TREE TIE, TYP. REMOVE BINDING TWINE 4 TOP 1/3 OF BURLAP 3" SETTLED DEPTH FINE BLEND BARK MULCH FERTILIZER TABLETS (4-21 GRAM-20-10-5) PLANTING SOIL //��/� ', ~:;;SIDES SCARIFY PLANTING PIT AND BOTTOM UNDISTURBED GROUND �/ / `: .':: / ��/��/ .•:..: \' 6" DEEP, FIRM, NATIVE 12" MIN. FOR WOOD ��\//�\//�\//� \//�\//� //� / y SOIL MOUND STAKES 4 IS" FOR REBAR IN HEAVY SOILS, AUGER 8"x(o' DEEP 2x ROOTBALL WIDTH HOLE (OR THROUGH HARDPAN) FILL WITH CRUSHED ROCK. VERIFY GOOD DRAINAGE PRIOR TO PLANTING. DECIDUOUS TREE PLANTING & STAKING DETAIL NOT TO SCALE PRUNE DISEASED AND BROKEN BRANCHES CHAINLOCK TREE TIE, TYP. 2x2 PINE TREE STAKES SET STAKES PERPENDICULAR TO PREVAILING WIND REMOVE BINDING MATERIAL AND TOP 1/3 OF BURLAP WATERING BASIN 3" SETTLED DEPTH FINE GRADE BARK MULCH AMEND NATIVE SOIL WITH (o" DEPTH 3-WAY MIX TOPSOIL FERTILIZER TABLETS (4-21 GRAM-2(I-10-5) SCARIFY PIT SIDES AND BOTTOM FIRM NATIVE 501L MOUND CONIFEROUS TREE PLANTING & STAKING DETAIL GROUNDCOVER PLANTS, SEE PLANT LIST TOPSOIL DEPTH AND TYPE AS — SPECIFIED BARK MULCH — DEPTH AS SPECIFIED EXISTING ---/ SUBGRADE 1/2 DIA. OF PLANT OR AS SHOWN ON DRAWING NOT TO SCALE EQUAL SPACING GROUNDCOVER PLANT EDGE OF PAVING SPACING AS INDICATED OR PLANTING ON PLANT LI5T BED PLAN SHRUB AND GROUNDCOVER SPACING DETAIL Call 2 Working Days Before You Dig 811 Utilities Underground Location Center (ID,MT,ND,OR,WA) NOT TO SCALE A PORTION OF THE SE 1/4 OF SECTION 19, TWP, 23 REG, 5 E, WM 1 POST CAP (TYP) 1 4x4 P.T. POST 1 x4 CEDAR TOP RAIL X_ 2x4 HEM FIR OR CEDAR 1x4 CEDAR ON EDGE 1x6 CEDAR BOARDS 8'-0" MAX. 1 " GAP OUTSIDE INSIDE I � L IVIHR. JrHl..11vh BETWEEN BOARDS 1x6 CEDAR BOARDS 1 x4 EDGE CEDAR (OUTSIDE) U 1 x2 HEM FIR OR CEDAR (INSIDE) NOTE: WOOD TO BE STAINED WITH RODDA RURAL MANOR SEMI —TRANSPARENT STAIN; CLEAR BASE MIXED WITH IS02G3806, OR EQUAL. STANDARD FENCE DETAIL m PLANT 1" HIGHER THAN IN NURSERY FINISH GRADE EXISTING NATIVE 61I 0 02/14/2025 1 STATE OF 2 WASHINGTON REGISTERED L NDSCAPE ARCHITECT LEANNE D. KUHLMAN CERTIFICATE No. 743 NO NOT TO SCALE PRUNE DISEASED AND BROKEN BACKFILL PLANTING HOLE HALF -FULL WITH NATIVE SOIL AND TAMP TO STABILIZE ROOTBALL. DO NOT DISTURB ROOTBALL. BACKFILL REMAINING HOLE WITH o AMENDMENT AS NOTED IN THE • PLANTING SPECIFICATIONS AND/ OR INSTALLATION NOTES. WATER THOROUGHLY. MULCH RING 3" SETTLED DEPTH FINE BLEND BARK MULCH X 2' DIAMETER, TO WITHIN 3" OF SHRUB STEM. DO NOT MOUND MULCH AGAINST SHRUB STEM ��,��\' \m `—SCARIFY SIDES OF PLANTING �'/O, .2j�\ j�\/\��\/j���// HOLE, ENSURE ADEQUATE DRAINAGE 2x ROOTBALL WIDTH FIRM NATIVE SOIL MOUND CONTAINER STOCK SHRUB PLANTING DETAIL NOT TO SCALE FIRST SUBMITTAL SECOND SUBMITTAL— RESPONSE TO COR COMMENTS THIRD SUBMITTAL— RESPONSE TO COR COMMENTS REVISION ESM 03 01 2024 SURVEYED: ESM 10/17/2024 DESIGNED: ESM 01/08/2025 BML DRAWN: CJR CHECKED: BY I DATE I APPR I APPROVED SCALE: (.o'-O'' O.C. (TYP) (0II 2"x4" SPLIT CEDAR RAIL (TYP) 6" DIAM. ROUGH CEDAR POST (TYP) (V C --- m _ a�►� / 7 f': CONC. FOOTING (TYP) f >n 14 . I f 1 I lm" * NOTE: FENCE SHALL BE LOCATED I" INSIDE THE BACK EDGE OF SIDEWALK- TYPICAL 2-RAIL NGPE FENCE DETAIL NOT TO SCALE LANDSCAPE NOTES 1. DO NOT DIG BEFORE LOCATING UTILITIES. 2. 5UBGRADE5, INCLUDING BERMS, TO WITHIN MOTH FOOT PROVIDED BY GENERAL CONTRACTOR UNLE55 OTHERWISE NOTED. 3. 5UBGRADE SHALL BE SCARIFIED OR ROTOTILLED IF CONDITIONS REQUIRE. 4. ,4PPLY ro" DEPTH TYPIC,4L 3-WAY MIX TOPSOIL IN ALL PLANTING AREA5 OR 45 OTHERWISE NOTED. 5. ,4PPLY 3" DEPTH FINE GRADE BARK MULCH IN ALL PLANTING AREA5. MULCH TO BE FREE OF WEED SEED, 5,4WDU5T, RESIN OR TANNIN AND SHALL NOT CONTAIN ANY COMPOUNDS DETRIMENTAL TO PL,4NT GROWTH. ro. CONTRACTOR 15 RESPONSIBLE FOR BRINGING ANY PROPOSED SUBSTITUTIONS OR UNFORESEEN FIELD CONDITIONS TO THE ATTENTION OF THE L,4ND5C,4PE ARCHITECT. -1. L,4ND5C,4PE ARCHITECT MAY ADJUST PLANT QUANTITIES OR VARIETIES 5,45ED ON ,AVAILABILITY OR FIELD COND ITION5. S. ALL PL,4NT MATERIAL SHALL BE D15E,45E FREE AND ARRIVE IN A V IGOROU5 GROWING CONDITION. e. ALL PL,4NT MATERIAL SHALL CONFORM TO U5,4 STANDARD FOR NURSERY STOCK, LATEST EDITION. 10- ALL TREE PITS SHALL BE INSPECTED TO INSURE PROPER DRAINAGE. IL POSITIVE DRAINAGE SHALL BE MAINTAINED. MOUND PLANTING AREA5 A MINIMUM OF 12" UNLE55 OTHERWISE NOTED. 12. CONTRACTOR AGREE5 TO WARRANTY AND MAINTAIN ALL PL,4NT MATERIAL FOR ONE FULL GROWING 5E,45ON P,45T INSTALLATION AND SHALL REPLACE DEAD PL,4NT MATERIAL WITHIN THAT WARRANTY / MAINTENANCE PERIOD WITH NO OBLIGATION TO THE OWNER. 13. STREET TREES SHALL HAVE UNIFORM BRANCHING HEIGHT OF 5 1/2' MINIMUM ABOVE GRADE OR 45 OTHERWISE NOTED. 14. STREET TREE LOCATIONS ARE 4PPROXIM,4TE AND SHOULD BE ADJUSTED PER STREET LIGHT AND UTILITY LOCATIONS. 15. ALL TREES SHALL BE DOUBLE 5T,4KED 45 SHOWN ON THE DETAILS. 5T,4KE5 TO BE REMOVED AFTER ONE FULL GROWING 5E,450N. TREES THAT HAVE DIED WITHIN THE ONE YEAR WARRANTY / MAINTENANCE PERIOD SHALL BE REPLACED AND RE-5T,4KED PER THE DETAIL. fro. ALL NEWLY PL,4NTED TREES SHALL INCLUDE A MULCH RING THAT H,45 A DEPTH OF AT LE,45T THREE INCHES (3") AND 15 AT LE,45T THREE FEET (3') IN RADIUS AROUND THE TREE. 1-1. L,4ND5C,4PE CONTRACTOR SHALL MAINTAIN 51TE UNTIL FINAL INSPECTION AND ACCEPTANCE BY OWNER AND REVIEWING AGENCY. .I� ONE INCH AT FULL SCALE IF NOT ONE INCH SCALE ACCORDINGLY VERTICAL: NAVD 1988 HORIZONTAL: NAD 1983/1991 CITY OF RENTON DATU M Planning/Building/Public Works Dept. )�- WIDE GREEN BORDER OUTLINE 1 INCH WIDE BORDER z 0.6 INCH TALL CIO U_ GREEN LETTERS, O ARIAL FONT a 0 H 0 a NATIVE GROWTH PROTECTION ARE, w• nm� "n w.wae 18" x 24" ALUMINUM WITH WHITE REFLECTIVE BACKGROUND, 1I.V RAOIUS CORNERS 1 j2 INCH TALL GREEN LETTERS, ARIAL FONT MOUNTING HOLES, TOP AND BOTTOM OF 81GN. 1A" GALVANIZED HARDWARE THROUGH POST SECURED TIGHT_ 7' x 4' x 4' PRESSURE TREATED POST WITH " CHAMFER AT TOP OR 2" DIA GALVANIZED SCHEDULE 44 STEEL POST WITH CAP, CONCRETE BASE, 12' DIA, x ZV DEEP 1. PLACE ONE NC•sPE SIGN AT THE MIDPOINT OF EACH LOT WITH POST SET IMMEDIATELY BEHIND NC•sPE FENCE. 2. DE51GN AND PROPOSED LOCATIONS FOR 5IGN5 SHALL BE 4PPROVED BY THE CITY OF RENTON. 3. SIGN SHALL READ- N,4711/E GROUITN PROTECTION E,45EMEN7 TH15 CRI7I0,4L 4RE,4, PL,4NTINC•r ,4RE,4, ,4ND UPL 4ND BUFFER 4RE PROTECTED TO PROVIDE LUILDL IFE 44,4517,47 ,4ND 1" 1,41NT,41N U),47ER QU,4L /7r PLE,45E DO NOT DISTURB 71L415 V,4LU,45LE RE50URCE NGPE SIGN DETAIL NOT TO SCALE R-431517 IN COMPLIANCE WITH CITY OF RENTON STANDARDS DEVELOPMENT ENGINEERING HHuynh 04/17/2025 SOPHIE JO SHORT PLAT FINAL LANSCAPE & TREE RETENTION/ REPLACEMENT PLAN DETAILS & NOTES UTILITY PERMIT # DATE: 11/19/24 PAGE DRAWING NO: LA-02 SHEET: OF: 21 23