Loading...
HomeMy WebLinkAboutCAG-20-065 - Duvall - A86 - Permanent Signing Washington State Department of Transportation Request for Approval of Material Contract Number FA Number SR Date N/A Duvall Ave NE CAG 20-065 2/2/2023 Section ITitle of Project Duvall Ave NE County King Contractor Reed Trucking & Excavating, Inc. Subcontractor This form shall be completed prior to submittal. If this form is not compete at time of submittal it may For WSDOT Use Only be returned for information that was omitted. RAM# 045D PE Use Bid Item Material or Name and Location of Fabricator, Specification PE/QPL Hdqtr./QPL HQ Use No, Product/Type Manufacturer or Pit Number Reference Code Code A86 Banding Band-It Project Engineer/Representative Date State Materials Engineer/Representative Date Michael Ballard 2/3/23 Acceptance Action Codes for use by Project Engineer and State Materials Laboratory 1. Acceptance Criteria: Acceptance based upon"Satisfactory"Test Report for samples of materials to be incorporated into project. 2. Acceptance Criteria: Mfg.Cert.of Compliance for'Acceptance prior to use of material. OAcceptance Criteria: Catalog Cuts for'Acceptance'prior to use of material. Catalog Cut Approved Q Yes ❑No 4. Acceptance Criteria: Submit Shop Drawings for'Approval'prior to fabrication of material. 5. Acceptance Criteria: Only'Approved for Shipment','WSDOT Inspected'or'Fabrication Approved Decal'material shall be used. 6. Acceptance Criteria: Submit Certificate of Materials Origin to Project Engineer Office. 7. Acceptance Criteria: Request Transmitted to State Materials Laboratory for Approval Action. 8. Source Approved: 9. Approval Withheld: Submit samples for preliminary evaluation. 10. Approval Withheld: 11. Miscellaneous Acceptance Criteria. Remarks (PE): Remarks (HQ): 201 Stainless Steel Band-It bracket shall have finish color: RAL 9005TX "Jet Black," or equivalent, where black finish color is required. For all other applications, 316 stainless steel fasteners shall be required DOT Form 350-071 Project Engineer Distribution Revised 03/2021 l Contractor ❑Region Operations Engineer ❑Fabrication Inspection �Region Materials p State Materials Lab-MS 47365 201 Stianless Steel BAND-IT®Band Page 1 of 1 201 Stainless Steel Band-It bracket shall have finish color: RAL 9005TX "Jet Black," or equivalent, where black finish color is required BAND l T( ABOUT BAND-IT LOCATIONS LITE CATALOG/ TECHNOL RESOUROGY ES& NEWS&MEDIA CAREERS CONTACT US Search t Go! , 11 r o MADE IN ". . U SA o o o o BAND-1T°DENVER CO F' j a as Latest News Applications Print Version • Banding New Technology to Install ■ Clamping 201 Stianless Steel BAND-IT®Band Boiler Tube Sacdfidal Shields Creates an Easy and • Bonding 201 Stainless Steel BAND-IT Band,bright annealed finish sets the standard in banding,clamping and Time Savings Installation • Identifying fastening with a combination of high strength and quality appearance. Offers good resistance to oxidation and many moderate corrosive agents. Read. • Search Applications (back to index) BAND-14 Products Bolt Clamp ■ Adjustable Clamping Systems ." i A■ 1 ■ Band&Buckle • Banding Systems I • As\i • Brack-Its&Mounting Hardware +" ,:an )1•- ■ Hose Fittings • Identification Systems 201 Stainless Steel BAND-T® 201 Stainless Steel BAND-IT®Band in • Preformed Clamping Band Totes Now Low a ti y_ P 9 Sallie Great Quality! ■ Stainless Steel Cable Ties • Tools • Custom Configured Products 201 Stainless Steel BAND-IT Band Now with EASY SCALE,a patented imprint on the band to determine band length. Eliminates costly waste and complicated measuring by allowing users to quickly and precisely roll out the length of band needed for any Industries clamp. No more guesswork! • 201 Stainless Steel offers good resistance to oxidation and many moderate corrosive agents Go • Utilized in general use banding applications • Can be used with clip style buckles to create band clamps • Packaged in a standard box or a durable plastic tote for easy dispensing A Ouick,Reliable 't= • Installs easily with the following tools:the Standard Banding Tool(C00169),the Heavy Duty Banding way to Attach Tool(C00369),the Bantam Tool(C07569),the Bantam Strapping Tool(C08569),the Rachel Tool Sacrificial Shields (C40099),and Pok-IT II Tool(J02069) the newest innovation by our team of expert engineers Does BAND-IT®offer any colored band to match the color of a decorative pole? PDF Why does BAND-IT®offer the same kind of band in cardboard and tote packaging? PDF Width Thickness Average Weight Use with Buckle Type Product Breaking Package&Quantity In. (mm) In. (mm)Strength Lbs. Kg Ear-Lokt Clip Scru- (Lys) Lok C20299 1/4 6.4 0.020 0.51 500 Box-100'Roll 1.7 0.7 C25299 None C72099 C20399 3/8 9.6 0.025 0.64 900 Box-100'Roll 3.2 1.5 C25399 L15399 C72299 C203Y9 3/8 9.6 0.025 0.64 900 Yellow Tote-100'Roll 3.6 1.6 C25399 L15399 C72299 C20499 1/2 12.7 0.030 0.76 1500 Box-100'Roll 5.1 2.3 C25499 L15499 C72499 C204B9 1/2 12.7 0.030 0.76 1500 Blue Tote-100'Roll 5.5 2.5 C25499 L15499 C72499 C20599 5/8 15.9 0.030 0.76 1875 Box-100'Roll 6.4 2.9 C25599 L15599 C72599 C205G9 5/8 15.9 0.030 0.76 1875 Green Tote-100'Roll 6.8 3.1 C25599 L15599 C72599 C20699 3/4 19.1 0.030 0.76 2250 Box-100'Roll 7.7 3.5 C25699 L15699 C72699 C206R9 3/4 19.1 0.030 0.76 2250 Red Tote-100'Roll 8.2 3.7 C25699 L156" Notes Also available in Mill coil lengths SUBMITTAL REVIEW Application Tools No Exceptions Taken • X Make Corrections Noted Amend &Resubmit • .. Rejected-See Remarks C00169 BAND- C00369 Heavy Duty C07569 C08569 Bantam C40099 Ratchet Jo; IMPORTANT NOTICE:This review IT®Tool BAND-ITO Tool Bantam Tool Strapping Tool Tool does not relieve the Contractor from Notes •The Pok-It II Tool can be used with 3/8"maximum width product. responsibility to comply 8,conform with the Plans, Specifications, and Copyright 2010 BAND-IT-IDEX,INC.-Privacy Policy-Contact Us Site map Contract Documents. C;ray&Osborne,Inc. CONSULTING ENGINEERS By MB Date:2/3/23 http://www-band-it-idex-com/en/products/Band%20%26%20Buckle/201%20S IVWashington State , r Department or Transportation Request for,Ap roval of Material•• Contract Number - FA Number SR Date CAG 20-065 _ _ N/A Duvall Ave NE 1/9/2023_ _ Section ITitle of Project Duvall Ave NE County King Contractor Reed Trucking & Excavating, Inc. Subcontractor _. - This form shall be completed prior to submittal.If this form is not compete at time of submittal it may !, For WSDOT Use Only be returned for Information that was omitted. RAM# 045C PE Use Bid Herb- Material or —Name and Location of Fabricator, Specification PE/QPL Hdqtr./QPL HQ Use No. Product/Type, Manufacturer or Pit Number Reference Code Code A86 Post Nucor 3 A86 Banding ,• Band-It 10 Project Engineer/Representativee Date State Materials Engineer/Representative Date _ �--� 1/17/23 Acceptance Action Codes for use by Project Engineer and State Materials Laboratory 1. Acceptance Criteria: Acceptance based upon"Satisfactory"Test Report for samples of materials to be incorporated into project. 2. Acceptance Criteria: Mfg.Cert.of Compliance for'Acceptance'prior to use of material. °Acceptance Criteria: Catalog Cuts for'Acceptance'prior to use of material.Catalog Cut Approved ®Yes 0 No 4. Acceptance Criteria: Submit Shop Drawings for'Approval'prior to fabrication of material. c 5. Acceptance Criteria: Only'Approved for Shipment','WSDOT Inspected'or'Fabrication Approved Decal'material shall be used. 6. Acceptance Criteria: Submit Certificate of Materials Origin to Project Engineer Office. 7. Acceptance Criteria: Request Transmitted to State Materials Laboratory for Approval Action. 8. Source Approved: 9. Approval Withheld: Submit samples for preliminary evaluation. 10. pproval Withheld: Fasteners shall be Type 316 Stainless Steel per S.P. 8-21.2 11. Miscellaneous Acceptance Criteria. Remarks Banding shall be black for luminaire poles, per S.P. 6-07.2 (PE): Remarks (HQ): DOT Form 350-071 Project Engineer Distribution Revised 03/2021 ®Contractor ❑Region Operations Engineer ❑Fabrication Inspection ❑Region Materials ❑State Materials Lab-MS 47365 Date:5/21/2021 To:Northwest Steel V C 0 R- 8228 W.74TH STREET https://www.nucortubular.com CHICAGO,IL 60638 'hops://www.ntpportal.corn TUBULAR PRODUCTS Tel:708-496-0380 Certificate Number:CHI 524044 Fax:708-563-1950 Sold By: Purchase Order No:16181 NUCOR TUBULAR PRODUCTS INC. Sales Order No:CHI 305362-7 CHICAGO DIVISION Bill of Lading No:CHI 185616-5 Shipped:2/5/2021 6226 W 74TH STREET Invoice No:CHI 413551-4 Invoiced:2/5/2021 CHICAGO,IL 60638 Tel:708 496-0380 Fax:708 563-1950 Sold To: Ship To: 1411-NORTHWEST STEEL&PIPE 1 -NORTHWEST STEEL&PIPE(RAIL) P.O.BOX 11247 4802 SOUTH PROCTOR STREET TACOMA,WA 98411 BN TRACK 532 SPIN#050824 TACOMA,WA 98409 CERTIFICATE of ANALYSIS and TESTS Certificate No:CHI 524044 Customer Part No: Test Date:1/25/2021 TUBING A500 GRADE B(C) Total Pieces Total Weight Lbs 2-1/2"SQ X 3/16"X 40' - 100 22,360 Bundle Tag Mill Heat Specs Y/T Ratio Pieces Weight Lbs 118450 4N 204007 YLD=57400/TEN=64077/ELG=26.32 0.8958 25 5,590 118451 4N 204007 YLD=57400/TEN=64077/ELG=26.32 0.8958 25 5,590 118452 4N 204007 YLD=57400/TEN=64077/ELG=26.32 0.8958 25 5,590 118453 4N 204007 YLD=57400/TEN=64077/ELG=26.32 0.8958 25 5,590 Mill#:4N Heat#:204007 Carbon Eq: 0.3276 Heat Src Origin:MELTED AND MANUFACTURED IN THE USA C Mn P S Si Al Cu Cr Mo V Ni Nb Sn 0.2000 0.5500 0.0070 0.0040 0.0180 0.0310 0.1410 0.0880 0.0210 0.0040 0.0590 0.0010 0.0090 N Ti Sb 0.0070 0.0010 0.0010 LEED Information(based on the most recent LEED information from the producing mill) Method Location Recycled Content Post Consumer Post Industrial EAF Crawfordsville,IN 74.5% 27.1% 47.4% Certification: I certify that the above results are a true and correct copy of records prepared and maintained by NUCOR TUBULAR PRODUCTS INC.Sworn this day,1/25/2021. THE SPECIFICATIONS LISTED BELOW REPRESENT THE CURRENT ISSUED DATES OF THESE STANDARDS.THIS DOES NOT INDICATE THAT THE MATERIAL ABOVE CONFORMS TO EACH OR ALL OF THE STANDARDS.WE CERTIFY THE MATERIAL ABOVE TO THE SPECIFICATION LISTED IN THE LINE DESCRIPTION. Chris Allen,ASQ CMQIOE CURRENT STANDARDS: Quality Systems Supervisor A252-19 A500/A500M-20 A513/A513M-20 ASTM A53/A53M-18)ASME SA-53/SA-53M-18 A847/A847M-14 A1085/A1085M-15 IN COMPLIANCE WITH EN 10204 SECTION 4.1 INSPECTION CERTIFICATE TYPE 3.1 Page-1 S EATTLE 4111 GALVANIZING COMPANY 6010 199th St.,Arlington,WA 98223® Phone(206)783-3100 m Fax(206)-783-3101®1-800-313-1545 DOCUMENT OF CERTIFICATION Customer: Northwest Steel &Pipe Address 4802 S Proctor St Tacoma,WA 98409 In Regards to JOB# All jobs in general (Zumar Anchors) Seattle Galvanizing Company certifies that the above referenced materials have been galvanized in accordance with ASTM A123/A123M and/or ASTM 153/A 153/M standards and meet the criteria specified therein. Juan Marquez Shipping and Receiving SUBMITTAL REVIEW X No Exceptions Taken Make Corrections Noted Inspected by: Amend & Resubmit Rejected-See Remarks AGA IMPORTANT NOTICE: This review does not relieve contractor from his J" Juan Marquez responsibility to comply& conform AGA Certified Galvanizing Inspector with the Plans, Specification, and Contract Documents. Gray 8r Osborne, Inc. CONSULTING ENGINEERS By. DRS Date: 1/17/23 201 Stianless Steel BAND-I1 land Page 1 of 1 CATATUREBAND-IT ABOUT BAND-IT LOCATIONS LITE LOG/ RESOURCESTECHNOLOGY B NEWS&MEDIA CAREERS CONTACT US al Search Goi (0) \'> () a MADE IN ',,-E U S A. 0 o cl o o BAND-IT®DENVER Latest News Applications Print Version • Banding New Technology to Install • Camping 201 Stianless Steel BAND-IT®Band Boiler Tube Sacrifidal Shields Creates an Easy and • Bundling 201 Stainless Steel BAND-IT Band,bright annealed finish sets the standard in banding,clamping and Time Savings Installation • Identifying fastening with a combination of high strength and quality appearance. Offers good resistance to oxidation and many moderate corrosive agents. Rr,a,1 • Search Applications __... (back to index) BAND-IT Bolt Clamp Products • Adjustable Clamping Systems Ilr AM • . 1 • Band&Buckle r a . 'r. • Banding Systems t , ,�\,. • Brack-Its&Mounting Hardware "� • IN- • Hose Fittings • Identification Systems 201 Stainless Steel BAND-IT® 201 Stainless Steel BAND-IT®Band in New Low Price • Preformed Clamping Band Totes Same Greet ! • Stainless Steel Cable Ties • Tools • Custom Configured Products 201 Stainless Steel BAND-IT Band Now with EASY SCALE,a patented imprint on the band to determine band length. Eliminates costly waste and complicated measuring by allowing users to quickly and precisely roll out the length of band needed for any 1. Industries clamp. No more guesswork! • 201 Stainless Steel offers good resistance to oxidation and many moderate corrosive agents Go • Utilized in general use banding applications • Can be used with clip style bucdes to create band damps Ow • Packaged in a standard box or a durable plastic tote for easy dispensing A Mick Raab • Installs easily with the following tools:the Standard Banding Tool(C00169),the Heavy Duty Banding Way to Attach Tool(C00369),the Bantam Tool(C07569),the Bantam Strapping Tool(C08569),the Rachet Tool Sacrificial Shields (C40099),and Pok-IT II Tool(J02069) The news.1nnn°.bo"by our teen,of expert engmeee Does BAND-IT®offer any colored band to match the color of a decorative pole? PDF Why does BAND-IT®offer the same kind of band in cardboard and tote packaging? PDF SUBMITTAL REVIEW width Thickness Average Weight Use with Buckle Type Product breaking Package&Quantity Scr„- No Exceptions Taken In. (mm) In. (min)Strength Lbs. Kg Ear-Lokt Clip(Lbs) Lok Make Corrections Noted C20299 1/4 6.4 0.020 0.51 500 Box-100'Roll 1.7 0.7 C25299 None C72099 Amend & Resubmit C20399 3/8 9.6 0.025 0.64 900 Box-100'Roll 3.2 1.5 C25399 L15399 C72299 -X- Rejected-See Remarks C203Y9 3/8 9.6 0.025 0.64 900 Yellow Tote-100'RoN 3.6 1.6 C25399 L15399 C72299 C20499 1/2 12.7 0.030 0.76 1500 Box-100'Roll 5.1 2.3 C25499 L15499 C72499 IMPORTANT NOTICE: This reviewC2o4B9 1/2 12.7 0.030 0.76 1500 Blue Tote-100'Roll 5.5 2.5 C25499 L15499 C72499 does not relieve contractor from hI c 2o599 5/8 15.9 0.030 0.76 1875 Box-100'Roll 6.4 2.9 C25599 L15599 C72599 C205G9 5/8 15.9 0.030 0.76 1875 Green Tote-100'Roil 6.8 3.1 C25599 L15599 C72599 responsibility to comply&conforrr C20699 3/4 19.1 0.030 0.76 2250 Box-100'Roll 7.7 3.5 C25699 L15699 C72699 with the Plans, Specification, and C206R9 3/4 19.1 0.030 0.76 2250 Red Tote-100'Roll 8.2 3.7 C25699 L15699 C72699 Contract Documents. Notes Also available in Mill coil lengths !_ 7 7 (iray�Z() I60rnc, Application Tools CONSULTING ENGINEERS ;� . , By: DRS Date:1/17/23 • C00169 BAND- C00369 Heavy Duty C07569 C08569 Bantam C40099 Ratchet J02069 Pok-It II IT®Tool BAND-IT®Tool Bantam Tool Strapping Tool Tool Tool' Notes *The Pok-It II Tool can be used with 3/8"maximum width product. Copyright 2010 BAND-IT-IDEX,INC.-Ps acy olic' - .nta. Us Si.ma, Fasteners shall be Type 316 Stainless Steel per S.P. 8-21.2 Banding shall be black for luminaire poles, per S.P. 6-07.2 http://www.band-it-idex.com/en/products/Band%20%26%20Buckle/201%20Stainless%2... 11/22/2011 • 11,7AA Washington State 111; orient of Transportation Request for Approval of Material Contract%mbar FA Number NIA SR Duvall Ave NE Date CAG 20-065 Section of ProjectDuvall Ave NE County King Contractor Reed Trucking & Excavating, Inc. Saiccetrelor This form shall be completed prior to submitt t. If this form is not compete at time of submittal it may For WSDOT Use Only be returned for information that was omitted. RAM*43--6 PE Use Bid item Material or Name and Location of Fabricator, Speailicgon PE/QP. Hdgt iQP1 HQ Use No. Product/kw Manufadhser or Pit Number Reference Code Code A86 Signing 3M Film Series 1170 8-21 3 A86 Fasteners Band-It IDEX Corp 8-21.2 10 Project Engineer/Representative - Date State Mated*EnglneerIRepresentattve Date 10/20/2021 Acceptance Action Codes for use by Project Engineer and State Materials Laboratory 1. Acceptance Criteria: Acceptance based upon'Satisfactory'Test Report for samples of materials to be incorporated into protect 2. Acceptance Criteria: Mfg.Cert.of Compliance for'Acceptance prior to use of material. 0 Acceptance Criteria: Catalog Cuts for'Acceptance'prior to use of material.Catalog Cut Approved ( 1 Yes ❑No 4, Acceptance Criteria: Submit Shop Drawings for'Approver prior to fabrication of material. 5. Acceptance Criteria: Only'Approved for Shipment',WSDOT Inspected'or'Fabrication Approved Decal'material shall be used. 6. Acceptance Criteria: Submit Certificate of Materials Origin to Project Engineer Office. 7. Acceptance Criteria: Request Transmitted to State Materials Laboratory for Approval Action. B. Source Approved: 9. Approval Withheld: Submit samples for preliminary evaluation. ()Approval Withheld: Fasteners shall be Type 316 Stainless Steel per S.P.8-21.2 11, Miscellaneous Acceptance Criteria. Remarks (PE): Remarks For for signal pole and luminaire poles that are painted black, (HQ): banding shall be In black color,per S.P.6-07.2. DOT Form 350-071 Project Engineer Distribution Revised 03/2021 ®Convector 0 Region Opsretions Engineer ❑Fabrication Inspection ❑Region Materiels Ekes Mate Lab-MS 4730 amScience. Applied to Life."' Traffic Safety and Security Division 3MTM ElectroCutTM Film Series 1170 Product Bulletin 1170 October 2016 Replaces PB 1170 dated July 2007 Description J3MT"ElectroCutT"Film Series 1170 is a durable,transparent,acrylic film coated with a transparent,pressure- sensitive adhesive that is protected by a removable liner,available in the colors in Table 1. Table 1.Product Codes by Color SUBMITTAL REVIEW Color Product ! X No Exceptions Taken Make Corrections Noted Clear 1170C Amend& Resubmit Yellow 1171 Rejected-See Remarks Red 1172 IMPORTANT NOTICE: This review Orange 1174 does not relieve contractor from his Blue ti 1175 responsibility to comply& conform with the Plans, Specification, and WorboyGreen• 1176 Contract Documents. Green 1177 Black(Opaque) 1178 Cray.&OallxsrrlueT jric. Brown 1179 CONSULTING ENGNrEEAS "Standard green color for U.K..Australia.and New Zealand By: DRS Date: 10/14/21 Series 1170 is intended for use on 3M Reflective Sheeting as part of 3M's system of matched components for signing.Series 1170 has a clear pressure-sensitive adhesive compatible with all the following 3M reflective sheetings used in permanent signing: 3M Advanced Engineer Grade Prismatic Series 7930 3M Engineer Grade Prismatic Series 3430 3M Engineer Grade Series 3290 3M High Intensity Prismatic Series 3930 and 3930TT 3M Diamond Grader"Series 3990 and 3990TT 3M Diamond Grade""DG3 Series 4000 and 4000TT 3M Diamond Grader"Translucent DG3 Reflective Sheeting 4090T 2 3MTM ElectraCuff Flm Series 1170 October 2016 Additionally,3MTM ElectroCut Film 1170C Clear must be used with the following-3M reflective sheetings: 3M Diamond Grade DG3 Prismatic Digital Sheeting 4090DS(White) 3M High Intensity Prismatic Digital Sheeting 3930DS(White) Series 1170 is designed with a special film liner for kiss-cutting on electronic cutting Machines.Rolls are available prepunched for sprocket fed cutters or unpunched for flatbed or friction fed cutters.The colored films in the Series 1170 are often used instead of silk screened inks to provide transparent colored background copy for retroreflective street name signs and other traffic control signs.Various film widths are available to fabricate single sign panels up.to'48 inches wide.For single panel signs requiring more than a single piece of sheeting or for multipanel signs such as guide signs;be sure to follow 3M color matching procedures in I'nfo•rmationFolder 1.10 to.achievesatisfactory.results.For best color uniformity on a colored'multipanel sign, all•panels must-be made from the same lot of Series 1170. Properties Transparent clear,yellow,red,orange,blue,worboy green,'green,black(opaque),and brown versions of the Series 1170 applied to compatible 3M retroreflective sheetings listed in the above section can be expectedto provide performance comparable to the integrally colored version of the'same reflective sheeting.The coefficient of retroreflection of a white sheeting overlaid with the Series 1170 depends primarily on the overlay film transparency and the coefficient of retroreflection of the white base sheeting.Series 1170 applied on the :compatible microprismatic 3M retroreflective sheeting's listed in the.above section"according to 3M recommendations will yield"chromaticity values within the chromaticity limits given in ASTM D4956-16. Table 1 gives the resultant minimum and maximum coefficient of retroreflection(RA)values for each 'transparent'Series 1170 film as a percentage of the RA of the white reflective base sheeting"on.which it is applied. _ Table 2.Coefficient of retroreflection*(RA)after application of colored film Series 1170 versus the RA of the white'basesheeting(expressed"as%) rMinimum Maiilmi m` Film (°!�of.boa's (Y of base" sheeting) sheebn9). • 1171(Yellow) 60 S0 1172(Rail) 14 24 1174(Orango) 30 -- 1175(Blue) 6.5 20 1176(WOrboy Green) 8 14 1177(Green) 13 20 1179(Brown) 5 - *RA measurements shall be made at 0.2°observation angle,.-4°entrance angle,and 0°rotation,per ASTM ES10, Film Liner Series 1170 films have a transparent film release liner designed to aid the cutting process and the removal of the film weed after cutting. Storage Store in a cool,dry area 65-75°F(18-24°C),30-50%relative humidity,and use within one year from date of receipt. 1, ,'-- )r` - - [v [ 1 3 3M"ElectroCute"Film Series 1170 October 2016 Fabrication — Cutting and Application Procedures Important Note:Read and follow the manufacturer's operating manual carefully for proper use of cutting equipment. 1. Adjust knife pressure to cut cleanly through the film and slightly score the liner.A 30°blade works best. 2: A clean tutting blade is required.To remove adhesive build-up use a soft cloth dampened with mineral spirits,isopropyl alcohol or 3M"'Citrus Base Cleaner. 3. Avoid excessive flexing when handling film as this may cause film to release from the liner. 4. After cutting is complete,lay sheets flat,face to face,back to back.Always store sheets in this manner until the sheeting has been weeded and transfer tape has been applied to sheeting. 5. Use a stripping tool designed for weeding films that has a blunt(not a sharp)edge. 6. After weeding is completed,also store sheets flat,face to face and back to back,until transfer tape is applied. 7. TPM-5 Clear Transfer Tape is recommended for best results.SCPM-3 Application Tape is also satisfactory for use on small signs.Other transfer tapes are not recommended. 8. Transfer tape can be applied either by hand using a plastic squeegee or through a hand squeeze roll applicator(HSRA).If applying the transfer tape by hand,care must be taken to always squeegee from the center to the outside in both directions.,If applying,the transfer tape through the HSRAthe air pressure must beat 30 psi to avoid stretching the prernask during application,and theiead".edge must be cut square and fed into the nip Very carefully to avoid wrinkles in the Series 1170. 9. Film Series 1170 may be applied to the sheeting either before or after the sheeting has-been appliedlto the substrate.Use of an HSRA is recommended:to ensure satisfactory results.Use the"split liner method"— start in the middle of the sheet and remove half the liner to ensure proper alignment. 10. After film Series 1170:and sheeting have been applied,remove the transfer tape by carefully removing the tape at as low an angle as possible. 11. IMPORTANT!When the transfer tape has been removed,reroll the sign through the laminator to ensure good adhesion. 12. Excess or overhanging film Series 1170 should be trimmed using a.sharp utility knife held at a 30°angle, with the substrate. Health and Safety Information Read all health hazard,precautionary,andfirst aid statements found in the Safety Data Sheets(SOS)and Article Information Sheets for important health,safety and environmental information.To obtain SDSs and Article Information Sheets for 3M products,go to 3M.com/SDS,.or by mail,or in case of an emergency,call 1- 800-364-3577. Warranty For detailed warranty information,please_refer to the sheeting product bulletins and:the:_3M MCS"!" Wajran y'forTraffic.and'MCS:WarrantyBulletiris. For Information or Assistance Call: 1-800-553-1380 In Canada Call: 1-800-265-1840 Internet: www.3M.com/roadwaysafety 3M assumes no responsibility for any injury,loss or damage arising out of the use of a product that is not of our manufacture.Where reference is made in literature to a commercially available product,made by another manufacturer,it shell be the user's responsibility to ascertain the precautionary measures for its use outlined by the manufacturer. 3M,3M Science.Applied to Life.,ElectroCut,Diamond Grade and MCS are trademarks of 3M.Used under license in Canada. Important Notice All statements,technical information and recommendations contained herein are based on tests we believe to be reliable at the time of this publication,but the accuracy or completeness thereof is not guaranteed,and the following is made in lieu of all warranties,or conditions express or implied.Seller's and manufacturer's only obligation shall be to replace such quantity of the product proved to be defective.Neither seller nor manufacturer shall be liable for any injury.loss or damage,direct,special or consequential,arising out of the use of or the inability to use the product.Before using,user shall determine the suitability of the product for his/her intended use,and user assumes all risk and liability whatsoever in connection therewith.Statements or recommendations not contained herein shall have no force or effect unless in an agreement signed by officers of seller and manufacturer. 3M Traffic Safety and Security Division 3M Canada Company 3M Mexico,S.A.de C.V. 3M Center,Building 0225-04-N-14 P.O.Box 5757 Av.Santa Fe No.55 St Paul.MN 55144-1000 USA London,Ontario N6A 4T1 Col.Santa Fe,Del.Alvaro Obragbn Please recycle.Printed in USA Phone 1-800-553-1380 1-800-3MHELPS Mexico,D.F.01210 f9 3M 2016.All rights reserved, Web 3M.com/roedwaysafety Electronic Only CUSTOMER SPECIFICATION DRAWING SUBMITTAL REVIEW No Exceptions Taken F * 1 .70±.02 •,- Make Corrections Noted X Amend & Resubmit Rejected-See Remarks I 1 . 1 . v), .1- % IMPORTANT NOTICE: This review does not relieve contractor from his 1 responsibility to comply&conform with the Plans, Spedfication,and 1 .50±.02 Contract Documents. \„: .- i flia) Grew Sr 081:porne, Inc. CONSULTING ENGINEERS By: DRS Date. loturti BOLT METAL WASHER 5/16 UNC THREAD 1/2" LENGTH FIBER WASHER BRACK-IT Is a --I i 71.1111111111111111111111111 711 11 III 1.60±.02 III SANO4 STAINLESS •••••••11.1/IIIIIIIIIIIIIIIIIIIIIIIIIIIII 111•11, .19±.02 -f- 2 PLACES Type 316 Stainless Steel per S.P.8-21.2 .81 +.02 2 PLACES NOTES: 1 . QUANTITY: 50 BRACK-ITS, 50 BOLTS, 50 SS WASHERS, 50 FIBER WASHES 2. MATERIAL: PER BAND-IT SPEC • BRACK-IT = 201 STAINLESS STEEL • FIBER WASHER = WHITE POLYPROPYLENE • METAL WASHER = 304 STAINLESS STEEL • BOLT = 304 STAINLESS STEEL ii-nZaEDL:illY 8 A unit of CENDE Corporation P.O. Box 16307 Denver, Colorado U.S.A. PROPRIETARY AND CONFIDENTIAL TITLE: DWG. NO, THIS DRAWING WITH ALL CONTENTS IS PROPERTY OF BAND4740E.X.INC. RepitODUCTION.DISCLOSURE OR mrG, BRACK-IT, FLARE LEG D02189 OF MATTER SHOWN IS PRONerTED wilViOuT wRITTEN RERmISSFON, WITH BOLTS AND CO NOT SCALE DRAwING, UNLESS OTHEMSE NOTED.DimENSIONS WASHERS REV B ARE V+I INCHES AFTER RNISN. CvstSpeckern /i20111 CUSTOMER SPECIFICATION DRAWING SUBMITTAL REVIEW No Exceptions Taken Make Corrections Noted r X Amend&Resubmit �t;orm-- Rejected-See Remarks IMPORTANT NOTICE:This review does not relieve contractor from his responsibility to comply&conform I ji - with the Plans, Specification, and E ll wde _�'" Contract Documents. —40-1 C Gray Sr Osborne,11120. H =INSULIN/3ING NEEi8 IBy: DRS Date: 10/14121 .1111/10111111111 J _I B �- A Q �- E .1 Type 316 Stainless Steel per S.P. 6-21.2 PART QTY DESCRIPTION A B C D E F G H pE WGT/BOX NUMBER BOX (Ibsa C 15399 3/8,200/300 SS,BOXED ,431/.406 .115/.095 .030±.002 .18 .625 .335/.275 .49 .13 100 .578 C 15499 1/2,200/300 SS,BOXED .565/.540 .130/.110 .030±.002 .19 .875 .411/.371 .63 .22 100 1.02 C15599 5/8,200/300 SS.BOXED ,695/_670 .115/.095 .030±.002 .19 .875 .42±.02 .77 .22 100 1.19 C 15699 3/4,200/300 SS,BOXED .812/.790 .135/.110 .044.±.003 .22 .875 .545/.505 .90 .22 100 2.05 NOTES: 1 . MATERIAL: 200/300 STAINLESS STEEL PER BAND-IT SPECIFICATION. 2. C15499 (1 /2) VALUCLIP SHOWN. uNLESS OTHERWISE NOTED: DIMENSIONS ARE IN INCHES AFTER FINISH / °?/2JLPfI[ll2=L777 ANCES;ANCES: P.Q. Box 16307 ,......,.. tat C 0 ,Xx ±0.020 Denver, Colorado U.S.A. .XX ±0.005 .XxxM..,.......,. ±0.001 ANGLE-.....,.t0,5' PROPRIETARY AND CONFIDENTIAL TITLE: DWG, NO. THIS DRAWING WITH ALL CONTENTS IS PROPERTY Of C l 53 BAND-ITADEX,WC. REPRODUCTION,DISCLOSURE OR VALUCLIP, BOXED MFG.OF MATTER SHOWN IS PROHIBITED WITHOUT WRITTEN PERMISSION. REV C SHEET 2 OF 2 DO NOT SCALE DRAWING c.atspecFc m 1 /2007 201 Stianless Steel BAND-IT®Band Page 1 of 1 Y, BAND-IT .0,,saxoTt' LOCATORS LI C4SALOG TERATUREr 14ESOURCES4 NEWS a MEC/A GAMMA QONTACY US Search Gar :' 5 A, a O ¶ o O BASED—IT.DENVEE < ••, < ',:, r d-' Latest News Applications Pnrt Yemen • 0 ndmg New Technekogy to Insret a Oansrny 201 Stianless Steel BANG-ITF',Band Birder Tube Santos Studds Creaks an Easy and • &nnNrr 201 Stainless Steed BAND-IT Band,bright annealed Enteh seta the standard In ban ing,clamping and Time Savings InEMatdton • tld ai ng fastening with a combination of high strength and quality appearance Offers good resistance to oxidation and many moderate corrosive agents. &mi.. • Search Arnp/calms ileatdk to index} Products • ink iata6ie Cleave%SeeSymere !s r• < ,-. a awn aR,ne T : a Sardine Systems t s i, • Sraxk.ire e'h-irons teed we ■ Hien Fdkngs • adlydlxatan*skims 20t Stainless Steel BAND.tT® 201 Stainless Sla•I BANDJTO Band in New Low a Preroi and Clamped Band Totes Sane Greet Quaky PrtCe ■ 91330r1645 swat coma rest a Tam • Orator Co mined P,duo 201 Stainless Steel BAND-IT Band Now nth EASY SCALE,a patentedarprintrm the bard ID dotrimane bard lengln Eliminatra(malty virile and cempicaled measuring by allowing users to quickly and precisely roil out 01e length or band needed for any Indtsbi•s clamp. No more guesswork! , 1 El • 201 Stainless Steel offers good resistarlon to osrdabon and many moderate r orroedve agents 00 • Utilized in general use bending applications t0 . ,-1 • Can be used with cop style buckles to create€tend damps ar • Packaged in a standard boa or a durable plastic Melia easy Cespensin9 A Quick Renew. Blier • installs easily with ills following tools:the Standard Banding Tool(C001691,the Heavy Duty Banding WayOa Wallach Tool 19003691,the Bantam Tool(C07569).the Mariam Sirappno Te.a:C69569LOne Rachet Tool !• W de (C400991.and Pok-IT rt Toni{J02069) rre+rr.,+o,.renby. eon.yawn tier..«+ Does BAND-IT&offer any colored band to match the color of a decorative poi'? PDF Why doss BANG-1181 offer the same kind of hand In cardboard and tote peckaghng? PDF Width Thickness Average Weight Use with Buckle Type Product Breaking Package&Quantity Soon in. imm► In imm)S }� Lbs. Kg Earikt o Clip Lek r C20299 1/4 8,4 0.020 0.31 sot: Box-100'Ron " 1 0 7 C25299 None C72099 C20399 378 9.6 0.025 064 000 „pox 100'Roll 1 2 1 5 C25399 L15399 C72299 C233Y9 378 9.0 0.025 0-04 400 'telew Tote -100'Rot 3.5 '.6 C25399 L15399 C72299 C20499 112 12.7 0.030 0.76 1500 pox-100'Roll _ 2 3 C25499 L15499 C72499 C204B9 112 12,7 0-Ot30 0.71$ 1500 Bleat Tins.I00'Roll a 5 2 5 C25499 L15499 C72499 C20599 518 15.9 0.430 75 1871 pus-100'Roll 5.1 2.9 C25599 L15599 C72599 C705(99 5,01 15.9 0 030 -1 70 1875 Otesm TO,-140'Rya 5,8 3.1 C23590 L 155€rJ e7 1:`..t9 C20699 3,4 19.1 0.030 0.76 2250 Boa-100'Rail 7.7 3.5F2sw-.. SUBMITTAL REVIEW 02o6 r01 3/4 19.1 a,,u ,76 2250 Red Tote-100'Roll 8.2 3.7 C25 ----- Notes Also available it 1041 col Ien.ttems, No Exceptions Taken - _ Make Corrections Noted Application Tools X Amend& Resubmit ♦ Rejected-See Remarks i \ IMPORTANT NOTICE: This review does not relieve contractor from his C!F01691114240 C00189Neavy at,., .-,r.. <<„-.39anlam C40099R; responsibility to comply &conform IT'S Toot BAND-1TBI Tool ::. :2.1-1 I ors saiapFing Tool Tool Neale 'The Pnk.h II Toot con In'i riot with 51W minimum width product. with the Plans, Specification, and Contract Documents 0a iylg9t 2070 BAND-IT.iaeu,Ile, .Pmacy Policy.(owes us.Sue reap 413Irdliy S OsL4or' e, inc. By: DRS CONSULTING ENGINEERS Date: 10/14121 http://www.band-it-idex.com/eniproducts/Band%20%26%120Buckle/201%20Stainless%2... 11/22/2011 • , . BAND-IT' 110ty BAND-IT IDEX,lnc 4799 Dahlia Street Deaver,CO 80216 February 22,-2017 Zumar Industries 12015 Steele St Tacoma,WA 98444 Certificate of Conformance • The material,used to make part number(s)C20699.and C25699 is'certified as type 201 stainless steel(UNS S20100),is manufactured in the U.S.to AISI standards,and is in,complete compliance with ASTM A666-15. This is to certify the material used,to make part number C15699 is certified as type 200/300 Stainless steel,is manufactured in the.U.S.to A151 standards,and is in complete compliance with ASTM-A-666-15. This,is to certify the material Used to make part number D02189 is certified as type.200/.300 stainless steel,is manufactured'in the U.K.to MI standards,and is in complete compliance with ASTM-A-666-15. The material used to make part number(s) SX0220-100 is.certified as type 304 stainless steel (UNS•530400),-is manufactured'in the UK,and:conforms to ASTM-A66645. 'Certified by: )0iti Brian Minter Quality Manager BM/Ira p;. r f �-'" i rye' t�3tY'µw BAND-IT IDBX,Inc 4799 Dahlia Street Denver,CO 80216 wwu.band-It-idexcom February 22,2017 Zumar Industries 12015 Steele St Tacoma,WA 98444 Certificate of Compliance DFARS 252.225-7009 Part Numbers: C20699 and C25699 This document certifies that the part number(s) listed above and manufactured by BAND-IT- IBEX,Inc.conform to DFARS 252.225-7009 directive regarding Preference for Domestic Specialty Metals. The material is melted in the United States of America or a qualifying country. February 22,2017 Brian Minter Date Quality Manager CUSTOMER SPECIFICATION DRAWING 1.70±.42 1.54±.42 1 BOLT METAL WASHER 5/16 UNC THREAD 1/2" LENGTH FIBER WASHER 9 BRACK-IT i— 111=1E11 s iq q SAND 1.64±.42 RAINLESS .19±.02 ------- ----- 2 PLACES .81 ±.02 2 PLACES NOTES: 1. QUANTITY: 50 BRACK-IT'S, 50 BOLTS, 50 SS.WASHERS, 50 FIBER.WASHES 2. MATERIAL: PER BAND-IT SPEC • BRACK:IT = 201 STAINLESS STEEL • FIBER WASHER = WHITE POLYPROPYLENE • METAL WASHER = 304 STAINLESS STEEL • BOLT = 304 STAINLESS.STEEL Eragt01=07® A unit of D 'Corporation P.O.Box 16307 Denver.Colorado U.S.A. PROPRIETARY AND CONFIDENTIAL Tif.E: DWG. NO.. THIS PRAWN,*WITH ALL CONTENTS F;S PROPERTYOF6AND-ET-IO INC. BRACK-IT, FLARE LEG D02189 REPRODUCTION,DCLOSUSURE OR MFG- OF MATTER SHOWN E E PERMISSION. WITH BOLTS AND WITHOUT WRITTENPERMISSION. UONOTTREb NOTED, WASHERS REV B UNLESS OTHERWISE IddTfO.DIMENSIONS ARE IN INCHES AFTER FINISH. 0.31SpeC€Orm 712010 .. . , • CUSTOMER SPECIFICATION DRAWING 4 - 1 .2 8 REF -‹zif.- . 77 + REF 7---- 5 REF TYP REF Ifi ----- p— � R E F _1 .,_-- I I11/ 1 'L- ___..-"" It__, .83 --- I I REF 1!7 'L-1 L- -czV I. l 1 1i^ ` 1 .j to 1 T_______ 1 _______T . 182 . 10 MIN TYP REF REF L LE5 . 28 REF rca r- . 52 REF NOTES: I . MATERIAL : 304 STAINLESS STEEL ABOVE SPECIFICATION CERTIFIED BY :. DATE: V. P. OF MFG . & ENG. THIS DRAWINGL WITH ALL CONTENTS IS PROPERTY OF BAND-IT. RE- PRODUCTION DISCLOSURE OR MFG_ A uoil of (7L S'Y ° Cor oration Wf MATTER $TTWN IS PROHIBITED r{�� �] P.O. Box 16301 P WITHOUT WRITTEN PERIPROHI8I t7, .6 09= Dearer, Colorado U.S.A_ DO NOT SCALE. DIMENSIONS ARE IN INCHES AFTER FINISH. TOLERANCE UNLESS NOTED TITLE DRAWING NO. .x 10. 1 ,xxx fo:oos UNIVERSAL CHANNEL S X 0 2 2 0 - I 0 0 ,xxxx ±0.001 CLAMP , HD ANGLES ±0.5° SHEET 2 OF 2 REV. . - 4t>♦ Washington State ♦/ Department of Transportation Request for Approval of Material Contact Number FA Number N,A SR CAG 20-065 _.._ Duvall Ave NE Ipate 10/5/2021 Section/Title of Protect Duvall Ave NE County King Contractor Reed Trucking & Excavating, Inc. This form shall be completed prior to submittal, If this form is not compete at time of submittal it may For WSDOT Use Only be returned for information that was omitted. RAM# 045A PE Use Bid Item Material or Name and Location of Fabricator, Specfication PE:QFL HdgtrlQPL HQ Use No. ProductType Mvslsctu er or Pit Number Reference Code Code A86 CMS 3M 8-21 3 • A _ f Project Engireer/Reoresentative Date State Materials Engineer/Representative Date - 10/6/2021 Acceptance Action Codes for use by Project Engineer and State Materials Laboratory 1. Acceptance Criteria: Acceptance based upon"Satisfactory"Test Report for samples of materials to be incorporated into project. 2. Acceptance Criteria: Mfg.Cert.of Compliance for'Acceptance'prior to use of material- OAcceptance Criteria: Catalog Cuts for'Acceptance'prior to use of matenal.Catalog Cut Approved Yes ❑No 4. Acceptance Criteria: Submit Shop Drawings for'Approval'prior to fabrication of material. 5. Acceptance Criteria: Only'Approved for Shipment', 'WSDOT Inspected'or'Fabn cation Approved Decal'material shall be used. 6. Acceptance Criteria: Submit Certificate of Materials Origin to Project Engineer Office. 7. Acceptance Criteria: Request Transmitted to State Materials Laboratory for Approval Action. 8. Source Approved: 9. Approval Withheld: Submit samples for preliminary evaluation. 10, Approval Withheld: 11. Miscellaneous Acceptance Criteria, Remarks (PE): Remarks (HQ): DOT Form 360.071 Project Engineer Distribution Revised 0312021 ®Contractor El Region Operations E' ineer Fabrication Inspection ❑Region Material's ❑State Materials Lab-MS 47-366 SUBMITTAL REVIEW X NO E*e OtiOnS Takur, _ Make Corrections Noted Amerce 8 Resubmit Rejected-Sae Remants 3IVI IMPORTANT NOTICE This review does not renew contractor from his responsibility to oompty&conform with the Plans,Specification,and Diamond Grade''mgab Contract bocumants DUReflective Sheeting Series 4000 ` `'� .`�`s 0.16 LOMW'.'wG E`iVMEE46 DRS Date 10/6/21 Product Bulletin 4000 January 2012 Description Color Product Code 3MTM Diamond Gradem DG' Reflective White - thermal transfer printable 4090TT Sheeting Series 4000 is a super-high efficiency, Yellow - thermal transfer printable , 409 ITT full cube retroreflective sheeting designed Fluorescent Yellow -TT printable. . . . . . .4081 TT for the production of traffic control signs and Fluorescent Yellow-Green-TT printable . ..4083TT delineators that are exposed vertically in service. DG3 sheeting is designed to have the highest Photometrics retroreflective characteristics at medium and short Daytime Color(x,y, Y) road distances as determined by the R values The chromaticity coordinates and total luminance at 0.5°and 1.0° observation angles in Table B. factor of the retroreflective sheeting conform to Performance at these observation angles represents Table A. the most common nighttime viewing geometries encountered by the driving public. During Color Test-Fluorescent Sheetings the daytime, Diamond Grade DG' fluorescent Conformance to standard chromaticity(x, y)and reflective sheeting provides higher visibility than luminance factor(Y%)requirements shall be ordinary(non-fluorescent) colored sheetings. determined by instrumental method in accordance Applied to properly prepared sign substrates with ASTM E 991 on sheeting applied to smooth Diamond Grade DG' reflective sheeting provides aluminum test panels cut from Alloy 6061-T6 or long-term retroreflectivity and durability. Series 5052-H38. The values shall be determined on a 4000 sheeting is available in the following colors. HunterLab ColorFlex 45/0 spectrophotometer. Computations shall be done for CIE Illuminant Color Product Code D65 and the 2°standard observer.' White 4090 Yellow 4091 Color Test-Ordinary Colored Sheeting Red 4092 Conformance to standard chromaticity(x,y)and Blue 4095 luminance factor(Y%)requirements shall be Green 4097 /determined by instrumental method in accordance Brown 4499 with ASTM E 1164 on sheeting applied to smooth Fluorescent Yellow - FY 4081 aluminum test panels cut from Alloy 6061-T6 or Fluorescent Yellow Green- FYG 4083 5052-H38. The values shall be determined on a Fluorescent Orange - FO 4084 HunterLab ColorFlex 45/0 spectrophotometer. Computations shall be done for CIE Illuminant D65 and the 2°standard observer.' fable . Daytime Color Specification Limits' Daytime Luminance Limit(Y%) C",drir • y x y Min. Max. White 0 303 0,3011 0.368 0.366 0.340 0393 0.274 0.329 27 Yellov. 0.498 0.412 0.557 0.442 0.479 0520 0.438 0.472 15 45 Red 0.648 0.351 0.735 0.265 0.629 0281 0.565 0.346 2.5 15 Blue 0.140 0.035 0.244 0.210 0.190 0255 0.065 0.216 I 10 Green 0.026 0.399 0.166 0.364 0 286 0.446 0.207 0.771 3 12 Brown 0.430 0.340 0.610 0390 0550 0.450 0.430 0390 I 9 FY 0.479 0.520 0.446 0.483 0.512 0.421 0.557 0.442 40 FYG 0387 0,610 0.369 0.546 0.428 0,496 0.460 0.540 60 FO 0.583 0.416 0.535 0.400 0595 0351 0.645 0.355 20 'The four pairs of chromaticity coordinates determine the acceptable color in terms of the CIE 1931 Calorimetric System. . . . , - . 'The instrumentally determined color values of :1).0lite+1'CoItM:0•114 Overlay Fi1E10 • . : retroreflective sheeting can vary significantly For screenprinted or thermally transfer printed depending on the make and model of colorimetric transparent color areas on white sheeting when spectrophotometer as well as the color and processed according to 3M recommendations, retroreflective optics of the sheeting (David M. the coefficients of retroreflection shall not be Burns.and Timothy J.Donahue, Measurement less than 70%of the value for the corresponding Issues in the Color Specification of Fluorescent color in Table B. For white sheeting covered Retroreflective Materials for High Visibility with 3MTm ElectroCutTm Film Series 1170 when Traffic Signing and Personal Safety Applications, processed according to 3M recorrimendations,the Proceedings of SPIE: Fourth Oxford Conference on Spectroscopy, 4826, pp. 3949,2003). For coefficients of retroreflection shall not be less than 100% of the value for the corresponding color in the purposes of this document,the HunterLab Table B.The color chromaticity and luminance ColorFlex 45/0 spectrophotometer shall be the shall conform to Table A on page 1. referee instrument. _ . . .., , • ,..g • Coefficients Of Retroreflection (RA) EntraHlime Angularkty Peribrni;400 iii ,_ , The values in Table.B are minimum coefficients ,Regard to'thitutatiop of retroreflection expressed in candelas per lux per : ' • • - : - 'Diamond Grade DO3 Reflective Sheeting is square meter(cd/lux/m2). designed to be an effective Wide angle.reflective sheeting regardless of its orientation pti the l'Test for Coefficients of Retroreflection,• substrate or ultimate orientation of the Signaller Conformance to coefficient of retroreflection installation. However, because the efficiency of requirements shall be determined by instrumental light return from cube corner reflectors is not method in accordance with ASTM E-8 10 "Test - e9ual at all'application orientations, especially Method for Coefficient of Retroreflection of with increasing entrance angles, it is possible to Retroreflective Sheeting",and per E-al 0 the get the widest entrance angle light return when the values of 0°and 90°rotation are averaged to sheeting is oriented in a particular manner. When determine the RA in Table B. high entrance angle(>50°)performance is required for given signs (e.g. Keep RightSymbols), it can Table.B-Minimum Coefficient of be' Retrorefleetion 1 for new sheeting(cd/itpamz) obtained easily by specifying the application orientation of the completed signs. In these -4°Entrance Angle' situations,the completed sign should have the Observation Angle sheeting positioned at the 0°orientation(downweb direction perpendicular to the road). White . '580 420 120 Yellow 435 315 90 When the "primary groove line"(or,flat side of Red 87 63' 18 the diamond shape)is vertical in the completed Green 58 42 12 sign, sheeting is said to be at'a 0°orientation. Blue 26 19. 5 When the"primary groove line"(or, flat side of Brown 17 13 4 the diamond shape)is horizontal in the completed Fluorescent Yellow 350 250 72 sign, the sheeting is said to be at a 90° orientation. Fluorescent Yellow Green 460 340 96 Fluorescent Orange 175 125 36 (Figure 1) 30°Entrance Angle3 12: 2,5: LE ilNil No II i[111 White 220 150 45Jill; 11N+Prirberry-Orppve Line •. I! i,•fi 111'ri 11 Yellow 165 110 34 v ' ' lit illif 41111117. Red 33 23 7 6, Green 22 15 5 Blue 10 7 2 Figure 1 Brown 7 5 1 Unless the sign location and/or position calls for Fluorescent Yellow 130 90 27 ' extra-wide entrance angularity performance,signs Fluorescent Yellow Green 180 120 36 and applied copy (letters,arrows, borders and Fluorescent Orange 66 45 14 shields) can be fabricated and installed using the i Entrance Angle—The angle from'the illumination application orientation that most efficiently utilizes axis to the retroreflector axis.The retroreflector axis is the reflective sheeting., an axis perpendicular to the retroreflective surface. Note: For multi-panel signs it is recommended Observation Angle—The angle between the that all background panels'be sheeted such that'the illumination axis and the observation axis. sheeting direction is the same for all panels. 2 fT A •Fabrication Lines: Remeasure RA. The manufacture of prismatic sheeting results in ,Requirement—The sheeting shall retain a lines being present in the product.In Diamond 'minimum of 85% and a maximum of 115%of the Grade DG3 sheeting these lines are slightly thicker original coefficient of retroreflection. than the seal pattern legs.Fabrication lines are noticeable in shop light but are not observable on 7Sign=l a> rication;Metllinds the road either in daylight or at night under typical - use conditions(Figure 2). Application Diamond Grade DG3 sheeting incorporates a pressure sensitive adhesive and should be applied to the sign substrate at temperature of 65°F/18°C 4,: ^L.;~ or higher by any of the following methods: Mechanical squeeze roll applicator—refer to 3M Information Folder(IF) 1.4. Application to extrusions that are edge wrapped requires sufficient softening of the sheeting. This can ACY Us! to1°width, be accomplished by directing additional heat to Figure 2-Fabrication Lines the"next to last" edge roller.This practice will increase productivity and minimize cracking. •Adliesve° Hand squeeze roll applicator—refer to 3M. IF 1.6. 1 iamorid3Grade DG3 sheeting has a pressure- Application of Diamond Grade DG3 sheeting for sensitive adhesive that is recommended for complete signs or backgrounds must be done with application at temperatures of 65°F(18°C)or a roll laminator, either mechanical or hand driven. higher. Hand Application • Hand application is recommended for legend and 'Adhesvve,ands fUim Properties copy only. Refer to'3M Information Folder 1.5 for Standard Test Panels more details. Unless otherwise specified herein, sheeting shall Hand applications will show some visual be applied to test panels and conditioned in irregularities, which are objectionable to • accordance with ASTM D4956 and test methods aesthetically critical customers. These are more and conditions shall conform to ASTM.D4956. noticeable on darker colors. To obtain a close-up I Properties uniform appearance,a roll laminator must be used. The following properties shall conform to.the All direct applied copy and border MUST be cut at requirements in ASTM D4956. all metal joints and squeegeed=at the joints. 1. Adhesion Splices 2. Outdoor weathering Series 4000 sheeting must be butt spliced when -retained coefficient of retroreflection more than one piece of sheeting is used on one -colorfastness piece of substrate.The sheeting pieces should not 3. Shrinkage touch each other. This is to prevent buckling as 4.Flexibility the sheeting expands in extreme temperature and 5. Liner removal humidity exposure. 6. Impact resistance . Double Faced Signs 7.Night time color The sheeting on the bottom side of a double In addition,DG3 sheeting will conform to the faced sign can be damaged if rolled through a following properties. squeeze roll applicator with an unprotected steel 1.Gloss bottom roller. The use of a semi-soft flat sheet Test Method—Test in accordance with ASTM between the steel roller and the applied sign face 1. D523 using a 60°glossnneter. will provide protection from damage. A material Requirement®Rating not less than 50. such as a rubber mat, tag board or cardboard is recommended. 2.Optical Stability Test Method—Apply a 3-inch x 6-inch sample to a test panel. Measure R then place it in an oven at 71°C±3°C(160°F±a F) for 24 hours followed by conditioning at standard conditions for two hours. 3 . o ;Substrates Care should be taken to avoid flexing DG3 For traffic sign use, substrates found to be sheeting before and especially after screening most reliable and durable are properly prepared to eliminate the possibility of cracking from aluminum sheets and extrusions. Users are urged improper handling techniques. to carefully evaluate all other Substrates for Thermal Transfer Printing. adhesion and sign durability. Other substrates Diamond Grade DU TT sheeting may be that may be satisfactory for proper application of imaged with 3MTht Thermal Transfer Ribbon sheeting will have the following characteristics: Series TTR2300 in conjunction with the Matan —Clean SprinG3 or Matan Spot4 thermal transfer printers. —Smooth For regulated traffic signs, Series TTR2300 —Flat Spot Traffic Colors are to be applied using Rigid these printers and must be covered with 31MMrM —Dimensionally stable ElectroCutni Film 1170. Refer to.Product Bulletin —Weather resistant TTR2300 for more information. —Non-porous 3MTM ElectroCutTM Film —High surface energy(passes water break test) 3MTh'ElectroCutmi Film Series 1170 may be Refer to Information Folder 1.7 for surface used to provide transparent colored background preparation recommendations. Substrates with low copy for traffic control signs on Diamond Grade surface energy may require additional preparation DG3 sheeting. Refer to Product Bulletin 1170 for such as flame treatment,mechanical abrasion or use fabrication procedures. of adhesion promoters prior to sheeting application. Applied Cut-Out Copy Guide sign extrusions may be edge wrapped.Flat Diamond Grade DU cut letters may be applied panels or unwrapped extrusions are to be carefully trimmed so that sheeting from adjacent panels does to a DG sheeting background to create a sign not,touch on assembled signs. legend. Such cut-out copy may be directly applied to the back ground sheeting,or may be applied in Diamond Grade DG3 sheeting is designed primarily a demountable form. Direct applied copy must be for applications to flat substrates.Airy use that cut at all panel seams and carefully trimmed back requires a radius of curvature Of less than five so that sheeting from adjacent panels does not inches should also be'supported by rivets or bolts. touch on assembled signs. Refer to Information Plastic substrates are not.recommended where' Folder 1.10 for more information. cold shock performance is required. Sign failures Note: It is recommended to fabricate all but the caused by the substrate or improper surface largest signs using 1170 electronic cuttable overlay preparation are not the responsibility of 3M.. film instead of direct applied copy. Imaging :Cutting: maybeprocessed Diamond Grade DG3 sheeting may be cut into, Diamond Grade DG3 sheeting letters and shapes of at least three inches in height into traffic signs by any of the imaging methods and stroke widths of at least one half inch. Smaller described below, 3M assumes:no responsibility for sizes are not recommended. Sealing cut edges of failure of sign face legends or backgrounds that DO sheeting is not required. have been processed with non-3M process colors or matched component imaging materials other Plotter Cutting than those listed below. Programmable knife cut(electronic cutting) Screen Processing 1. Flat bed plotters can either die cut or kiss Diamond Grade DG3 sheeting may be screen cut and offer the most consistent and reliable processed into traffic signs before or after Performance.. mounting on a sign substrate, using 3M Process 2. Friction Fed plotter. Kiss cut only. Success has Colors Series 880I or Series 880N. Series 880I or been achieved using plotters that have 600 grams 880N process colors can be screened at 60-100°F of down force and a 60°cutting blade..Additional (16-38°C)at relative humidity of 20-50%. A PE drive wheels may need to be added to improve 157 screen mesh with'a fill pass is recommended. tracking. An alternative procedure is to cut Refer to Information Folder 1.8 for details.No sheeting from the liner side. Blade force and knife clear coating is required or recommended. Use of depth must be set to score but not cut through other process colors series is not recommended. the topfrlm. Break apart individual copy or apply premask to retain spacing: 4 r. Other Cutting Methods Health,and: aifety'Informatioa. Diamond Grade DG3 sheeting may be hand cut Read all health hazard, precautionary or die cut one sheet at a time,and band sawed or p im'and firsDatat guillotined in stacks. Cutting equipment such as Said statements found in the Material Safety guillotines and metal shears, which have pressure handlingdt product label of any materials prior to plates on the sheeting when cutting, may damage or use.or the optics. Padding the pressure plate and easing it down onto the sheets being cut will significantly goRcre pottlit oge,Cans iicratio s reduce damage. Maximum stack height for cutting The durability of Diamond Grade DG3 sheeting Series 4000 sheeting is 1 1/2 inch or 50 sheets. and finished signs using 3M Matched Component Details on cutting can be found in Information materials will depend upon substrate selection Folder 1.10. and preparation, compliance with recommended application procedures, geographic area, Storageand-Packaging, exposure conditions, and maintenance. Maximum 3M Diamond Grade DG3 Sheeting should be durability of Diamond Grade DG3 sheeting can stored in a cool, dry area, preferably at 65-75°F be expected in applications subject to vertical (18-24°C)and 30-50% relative humidity and exposure on stationary objects when processed should be applied within one year of purchase. and applied to properly prepared aluminum Rolls should be stored horizontally in the shipping according to 3M recommendations provided in Information Folder 1.7. The user must determine carton. Partially used rolls should be returned to from the suitability of any nonmetallic.sign backing the shipping carton or suspended horizontally a rod or pipe through the core. Unprocessed sheets for its intended use. Sign failures caused by the should be stored flat. Finished signsand applied substr,ate or improper surface preparation pp are not the responsibility of 3M.Applications blanks should be stored on edge. to unprimed,excessively rough or non-weather Screen processed signs must be protected with resistant surfaces or exposure to severe or unusual SCW 568 slipsheet paper. Place the glossy side of conditions can shorten the performance of such the slipsheet against the sign face and pad the face applications. Signs in mountainous areas that with closed cell packaging foam.Double faced are covered by snow for prolonged periods may signs must have the glossy side of the slipsheet also have reduced durability. 3M process colors against each face of the sign. and ElectroCutTm Film,when used according to Unmounted screened faces must be stored flat and 3M recommendations,are;generally expected interleaved with SCW 568 slipsheet, glossy side to provide performance comparable to colored against the sign face. reflective sheeting. Custom colors, certain lighter Avoid banding,crating, or stacking signs. Package colors,heavily toned colors Or blends containing for shipment in accordance with commercially Atm spher gold may in have e eurtain geograpced hic accepted standards to prevent movement and areas may result in reduced durability. chafing. Store sign packages indoors on edges. Panels or finished signs must remain dry during Periodic sign inspection and regular sign replacement are strongly recommended in order shipment and storage. If packaged signs become for sign owners to establish their own effective wet,unpack immediately and allow signs to dry. service life expectation,beyond the warranty Refer to Information Folder 1.11 for instructions period on packing for storage and shipment. Installation., 3Yi:Basic.Pi od'i ctIJ arrartty and Nylon washers are required when twist style 1irit. ted.Reiriedy fasteners are used to mount the sign. 3MTTm Diamond Grademi DG3 Reflective Sheeting Series 4000 ("Product") is warranted to be free of defects in materials and manufacture at the :Cleaning time of shipment and to-meet the specifications Signs that require cleaning should be flushed stated in this Product Bulletin. If DG3 Sheeting is with water, then washed with a detergent solution proven not to have met the Basic Warranty on its and soft bristle brush or sponge. Avoid pressure shipment date, then a buyer's exclusive remedy, that may damage the sign face. Flush with water and 3M's sole obligation,at 3M's option,will be following washing. Do not use solvents to clean refund or replacement of the sheeting. signs. Refer to 3M Information Folder 1.10. 5 . . -Goners]N.WrrootY,Term ; Additional Warranty &limited:Remedy. ... .„.„ . . . . . • .. . 1. 3M makes the Additional Warranty(as defined -for'Oydiiiyaky colored Product below)as to any traffic control and guidance 1. The Additional Warranty for a Sign made with sign in the United States and Canada ("Sign") ordinary colored Product is that the Sign will: made with 3Mrm Diamond GradeTM DO (a) remain effective'for its intended use when Reflective Sheeting Series 4000 ("Product")and viewed from a moving vehicle under normal the Matched Component materials listed in Table day and night driving conditions by a driver E. Any Additional Warranty is contingent on all with normal vision,and (b) after Cleaning,will components involved in.that Additional Warranty meet the minimum values for coefficient of being stored, applied, installed, and used only as retroreflection stated in Table C for Table C's 3M recommends in its Product Bulletins and Other applicable Warranty Period'measured from the Product Information. Sign's FabricatiOn Date. 2. The Basic Warranty and any applicable Table C-Minimum Percent Retained of Table Additional Warranty are collectively referred to as B Initial R for applicable Warranty Period for the"3M Warranty."EXCEPT TO.THE EX IENT Ordinary Colors(white,yellow, red, green,blue PROHIBITED BY APPLICABLE.LAW,THE 3M and brown) WARRANTY IS MADE IN LIEU OF ALL OTHER WARRANTIES,RIGHTS OR CONDITIONS, EXPRESS OR IMPLIED,INCLUDING,BUT Warranty Period Minimum Percentage NOT LIMITED TO,ANY IUMPL1VD WARRANTY k.Retained OF MERCHANTABILITY,FITNESS FOR A PARTICULAR PURPOSE AND THOSE ARISING 1-7 Years 80% , FROM A COURSE OF DEALING, 70%-1 CUSTOM OR 8-12 Years USAGE OF TRADE. A BUYER IS RESPONSIBLE FOR DETERMINING IF A PRODUCT IS 2. If any Sign made with Ordinary Product is SUITABLE FOR ITS PARTICULAR PURPOSE proven not to have met the AdditiOnal Warranty, AND APPLICATION METHODS. then a buyer's exclusive remedy;.and 3M's,sole 3. A Sign's failure,to meet the 3M Warranty must obligation, at 3M's option: be solely the result of the Product or the matched (a) if this occurs within.seven years after the component materials' design or manufacturing Fabrication Date, then 3M will, at its expense, defects. 3M has no obligation under the 3M restore the Sign's surface to its original Warranty if a sign failure is caused by: effectiveness; or improper fabrication, handling, maintenance or (b) if this oCcitrs during the remainder of installation; non-vertical applications where the the Additional Warranty Period, then 3M Sign'face is more than+/- 10%from vertical;use will furnish only the necessary 3M sheeting of any material or product not Made by 3M or not Product and matched component materials included in Table E; use Of application equipment quantity to restore the Sign's surface to its not recommended by 3M; failure of sign original effectiveness. substrate; lOsS of:adhesion due to incompatible or improperly prepared substrate;:exposure to .. .• . . chemicals, abrasion and other mechanical damage; .AdditiOir4.!lWarraii0. .!?4. :11:.;.:im. ,ited:lie...ine,tifY: snow burial or any other sign burial; collisions, for einoreiciot.Pititinct •- ,.. ._, vandalism or malicious mischief . . . 1. The Additional Warranty for a Sign made 4. 3M reserves the right to determine the:method of with Fluorescent Product is that the Sign will: replacement,and:any replacement Product will have (a) remain effective for its intended use when the remainder of the original Product's unexpired 3M viewed from a moving vehicle under normal Warranty. Claims made under this warranty will be day and night driving conditions by a driver honored only if with normal vision; (b) after cleaning, will retain -The Sign was dated upon completion of fabrication 7O% of the minimum values for coefficient ("Fabrication Date")using a permanent method(sticker, of retroreflection stated in Table B for the permanent marker or crayon,metal stamp,etc.) applicable Warranty Period stated in Table D, measured from Fabrication Date; and (c) after -3M is notified of a 3M Warranty claim during any cleaning, the fluorescent Product will maintain applicable Warranty Period-and the owner or fabricator daytime luminance equal to or greater than the provides the information reasonably required by 3M to minimums specified in Table A. verify if a 3M Warranty is applumbla 6 . h Table D—Warranty Period for Table E.Matched Component Materials. Fluorescent Colors. l'idatelied Components Color Warranty Period Process Colors Series 8801 Process Colors Series 880N Fluorescent Yellow ion Years 6 Thermal Transfer Fluorescent Yellow Green 10/7 Years' Ribbons—Spot Traffic. Series TTR2300 Fluorescent Orange 3 Yeats Colors only* - . ElectroCutTm Film Series 1170 Premium Protective Series 1160 ' Due to climatic conditions, Signs.in Alabama, Overlay Film Arizona, Florida, Georgia,Hawaii, Louisiana, Slipsheet SCW 568 Mississippi,New Mexico, South Carolina and Prespacing Tape SCPS-2 Texas have the 7-year Additional Warranty Period. Preniasking Tape SCPM-3 '2. If a Sign made with Fluorescent Product is Transfer Tape TPW5, proven not to have met the Additional Warranty, 6 Must be covered with 3MTm ElectroCtitTM Film 1170 then a buyer's exclusive remedy, and 3M's sole. obligation, at 3M's option: Refer to 3M Information Folders and Product (a) for those Fluorescent Products with a Bulletins fordetailedinfonnation about 10-year Additional Warranty Period,3M will, recommended application procedures and equipment, at its expense: (a) restore the Sign's surface to . . . . . . . its original effectiveness if this occurs within b.thietoroiltilet Itliftirniaiiktll• seven years after the Fabrication Date; or(b) furnish only the necessary 3M Fluorescent Always confirm'that you have the most current Product and matched component materials version of the applicable Product Bulletin, quantity to restore the Sign's surface to its Information Folder or Other Product Information. Original effectiveness if.this occurs during the remainder of the.Warranty Period. IF 1.4 Instructions for Interstate Squeeze (b) for those Fluorescent Products with a Roll Applicator 7-year Additional,Warranty Period, 3M will, IF 1.5 Hand Application Instructions at its expense: (a) restore the Sign's surface to its'original effectiveness if this occurs within. IF 1.6 Hand Squeeze Roll Applicator five years after the:Fabrication Date; or(b) IF 1.7 Sign Base Surface Preparation furnigh only the necessary 3M Fluorescent Precinct and matched component.materials IF 1.8 Process Color Application quantity to restore the Sign's surface to its Instructions original effectiveness if this occurs during the remainder of the Warranty Period. IF 1.10 Cutting, Premasking,:and Prespacing (c) for those Fluorescent Products with a IF 1.11 Sign Maintenance Management 3-year Additional Warranty Period, 3M will PB 8801 Process Color 8801 finish only the necessary Fluorescent Product and matched component materials,quantity PB 880N Process Color 880N to restore the Sign's surface to.its original. effectiveness. PB 1170 ElectroCutTM Film PB TTR2300 Thermal Transfer Ribbons Series TTR2300 PB 1160 Protective Overlay Film 1160 7 LOrilitatiOIrkAit 13,40V 3M WILL NOT UNDER ANY CIRCUMSTANCES BE LIABLE TO A BUYER FOR DIRECT(other than the applicable Limited Remedy stated above),SPECIAL, INCIDENTAL,INDIRECT OR CONSEQUENTIAL DAMAGES(INCLUDING;WITHOUT LIMITATION, LOSS'OF PROFITS)IN ANY WAY RELATED TO A PRODUCT OR THIS,PRODUCT BULLETIN, REGARDLESS OF THE LEGAL OR EQUITABLE THEORY ON WHICH SUCH DAMAGES ARE SOUGHT. ASTM Test Methods are available from ASTM International,West Conshohoken,PA. 3M assumes no responsibility for aniy injury,loss or damage arising out of the use of a-priOduct that is not our nienilfactiire.Where IS made in literature to a commercially available produbt.made by another Manufacturer,it shall be the user's responsibility to.ascertainthe precautionary measures-for Its use outlined.by the manufacturer. Important-Notice Ail statements,technical-Moan-doh and.reCammeindatidns contained herein.are based On tests we believe.to be'triable,but the accuracy or completeness thereais not guaranteed,.andthe following Is Made in lieu of all warranties,or conditions express or implicit:Gellert and manufacturer's only obligation shall beto replace such quantity of the product proved tote defective.Neither seller nor manufacturer shall be liable for any injury,lessor damage,direct.speciaior consequential,arising out ofthe use of or theinabilitYto use the product Befbreusing; user shall determine the suitability of the product for hisiher intended use,and user assumes all riskand IIabiflty whatsoever in connection Therewith.Statements or recommendations not contained hereirishall have no force or effect unless in an agreement signed by officers of seller and manufacturer: 3M and Diamond Grade are trademarks of 3M.Used under license In Canada. 31111 Traffic Safety Systems Division 3M Canada Company 3M Mexico,S.A.de C.V. 3M Center,Building 0235-03-A-06 P.O.eox 5757 Av.Santa Fe NO;55 Please recycle. St Paul,MN 55144-1000 London,Ontario NSA 4T1 Col.Santa Fe,Del.Alvaro Obregon 6,310 2011.Al rights reserved. 1-800-553-1380 1-8004MHELPS Mkico,D.F.01210 Bolger 12016104 wunraNI.comitss Electronic Only � Washington State T!/ Department of Transportation Request for Approval of Material Contract Ntanber FA Number k IA SR Duvall Ave NE Date CAG 20-065 9/2/2021 Section t ilie of Project Duvall Ave NE County King Contractor Reed Trucking & Excavating, Inc. Subcontractor This form shall be completed prior to submittal. If this form is not compete at time of submittal it may For WSDOT Use Only be returned for Information that was omitted. RAM N 045 PE Use Sid Item Material or Name and Location of Fabricator, Specification PtJQPL HdgtrJQPt H0 Use No. ProducUftrpe , Manufacturer or Plt Number Reference Code Code A86 Signs Vulcan 8-21 10, 3, 8 Project Engireer/Reoresentative -t- Date State Materials Engineer/Representative Date - ". -, 9/30/2021 Acceptance Action Codes for use by Project Engineer and State Materials Laboratory 1. Acceptance Criteria: Acceptance based upon"Satisfactory"Test Report for samples of materials to be incorporated into project. 2. Acceptance Criteria: Mfg.Cart.of Compliance for'Acceptance'prior to use of material. 9 Acceptance Criteria: Catalog Cuts for'Acceptance prior to use of material.Catalog Cut Approved ( ]Yes ❑No Acceptance Criteria: Submit Shop Drawings for'Approval'prior to fabrication of material. 5. Acceptance Criteria: Only'Approved for Shipment', 'WSDOT Inspected'or'Fabrication Approved Decal'material shall be used. 6. Acceptance Criteria: Submit Certificate of Materials Origki to Project Engineer Office. 7. Acceptance Criteria: Request Transmitted to State Materials Laboratory for Approval Action. 0 Source Approved: See Remarks 9. Approval Withheld: Submit samples for preliminary evaluation. 0 Approval Withheld: See Remarks 11 Miscellaneous Acceptance Criteria. Remarks I (PE): Confirm sign fabricator *See Special Provisions 8-21.2 for sheeting coefficient of retroreflection requirements *,Provide clarification on use of 2-1/2" square steel tubing. Lower sign support shall be HOG. Remarks •Corner bolt shall be ASTM A307 Steel. (HO): •Provide submittal for vinyl adhesive graphic film and adhesive and film properties test results *Provide submittal for sign plate fasteners (for pole or luminaire mount). *Provide shop drawings of each street name sign, see requirements in Special Provisions 8-21.3. DOT Form 350-071 Project Engineer Distribution RRVlsed 03/2021 ©Contractor 0 Reg on Operations Engineer 0 Fabrication Inspection El Region%eerier* El State Matenaa ab-MS 41365 'IY:1n Aluminum 1c41 A;tun-0F Vulcan.inc. 400 EAST BERRY AVE P 0 BOX 1850 FOLEY ALABAMA 3016-18541 • i2511643-COIL FAX(251)943-75081 MANUFACTURER'S CERTIFICATE OF COMPLIANCE Confirm Zumar is the Description: Sheet Aluminum sign fabricator. This is to certify that the referenced materials supplied to Zumar Industries, Inc. comply in all respects with the following specifications. Sheet Aluminum—ASTM B209, alloy 5052-H38 Chromate Conversion—ASTM B449, Alodine 1200 finish Sincerely, SUBMITTAL REVIEW VULCAN ALUMINUM X No Exceptions Taken Make Corrections Noted Amend & Resubrrxt .„. Rejected-See Remarks David B. Beviacqua IMPORTANT NOTICE This review General Manager does not relieve the Contractor from responsibility to comply&conform with the Plans, Specifications. and Contract Documents, Gray Lac- Sworn to and subscribed by mc on this 16'"day of October 2018 C0.028.111G DMIMEERS 0 By MB Date: 9/20/21 0 TE '„ c- ciAalsk.4. •••...4. et's-.• Bernadette Dearborn.Notary Public - State of Alabama • • . County of Baldwin ,. 7.kx, .• ••• • 'Is rATT, AN EMPLOYEE OWNED COMPANY" anScience. Applied to Life:" 3MTM Diamond Grader"" DG3 Reflective Sheeting Series 4000 or approved equal Transportation Safety Division 3MTM High Intensity Prismatic Reflective Sheeting Series 3930 Product Bulletin Series 3930 SUBMITTAL REVEW May 2018 No Exceptions Taken Make Conyctlone Noted Amend&Resubmit Replaces Product Bulletin 3930 Dated January 2013 X Rejected-See Remarks IMPORTANT NOTICE:This review Optical stability of the sheeting shall retain a does not relieve the Contractor*ern responsibility to comply b conbrm minimum of 85%and a maximum of 115% of the with the pis,Specifications. and original coefficient of retroreflection (SP 8-21.2). contract Documents. 41lb (31,ay 8t Osbane,Inn. CONSULTING EieGINEONS 1 By: DRS Date: 9l30/21 Description High Intensity Prismatic Reflective Sheeting Series 3930("Sheeting")is a non-metalized microprismatic lens reflective sheeting designed for use in the production of durable reflective traffic control signs,work zone devices, and delineators that are exposed vertically in service("Signs").Applied to properly prepared Sign substrates, 3M Series 3930 prismatic Sheeting provides long-term reflectivity and durability. Series 3930 Sheeting is available in the following colors. Table 1.Product Codes by Color Color ►roduct Code White 3930 Yellow 3931 Red 3932 Orange 3934 Blue 3935 Green 3937 Brown 3939 2 3MT"High Intensity Prismatic Reflective Sheeting Series 3930 May 2018 2 Specifications 2.1 Daytime Color (x, y, Y) The chromaticity coordinates and total luminance factors of the retroreflective Sheeting conform to the limits presented in Table 2. Table 2.Daytime Color Specification Limits' Cok>r�. 1 ��2� 3 4 Reflectance Unlit lit(Y) x y I y 't y x f y Mlnhswm ; Maximum White 0.303 0.300 0.368 0.366 0.340 0.393 0.274 0.329 27 Yellow 0.498 0.412 0.557 0.442 0.479 0.520 0.438 0.472 15 45 Red 0.648 0.351 0.735 0.265 0.629 0.281 0.565 0.346 2.5 15 Orange 0.558 0,352 0.636 0.364 0.570 0.429 0.506 0.404 10 30 Blue 0.140 0.035 0.244 0.210 0.190 0.255 0.065 0.216 1 10 Green 0.026 0.399 0.166 0.364 0.286 0.446 0.207 0.771 3 12 Brown 0.430 0.340 0.610 0.390 0.550 0.450 0.430 0,390 1 9 a. The four pairs of chromaticity coordinates determine the acceptable color in terms of the CIE 1931 Standard Colormetric System. 2.2 Color Test - Ordinary Colored Sheeting Conformance to standard chromaticity(x,y)and luminance factor(Y%) requirements shall be determined instrumentally, in accordance with ASTM E1164,on Sheeting applied to smooth test panels cut from aluminum alloy 6061-T6 or 5052-H38.Chromaticity and luminance factor values shall be determined using a HunterLab ColorFlex 45/0 spectrophotometer.l Calculations shall be performed using CIE Illuminant D65 and the 2°standard observer. 2.3 Coefficient of Retroreflection (RA) The values shown in Table 3 are minimum coefficients of retroreflection,expressed in candelas per lux per square meter(cd/lux/m2). Table 3.Minimum Coefficient of Retroreflection RA for New Sheeting(cdflux/m2) 1 EntranceAnpb' Sheeting Color ^mu Obeerve4on Anpleb 0.2* j 0.5° White 560 200 Yellow 420 150 Red $4 30 Orange 210 75 Blue 30 13 Green 56 21 Brown 18 7.5 White 280 100 Yellow 210 75 Red 42 15 30' Orange 105 37 Blue 14 6 Green 28 10 Brown 8,5 3.5 a. Entrance Angle-The angle from the illumination axis to the retroreflector axis.The retroreflector axis is an axis perpendicular to the retroreflective surface. b. Observation Angle-The angle between the illumination axis and the observation axis. 1. The instrumentally determined color values of retroreflective sheeting can vary significantly depending on the make and model of colorimetric spectrophotometer used,as well as the color and retroreflective optics of the sheeting(David M.Burns and Timothy J.Donahue,Measurement Issues in the Color Specification of Fluorescent Retroreflective Materials for High Visibility Traffic Signing and Personal Safety Applications, Proceedings of SPIE:Fourth Oxford Conference on Spectroscopy,4826,pp.39-49,2003).For the purposes of this document,the Hunterlab ColorFlex 45/0 spectrophotometer shell be the referee instrument. 3 3MT"High Intensity Prismatic Reflective Sheeting Series 3930 May 2018 2.4 Test for Coefficient of Retroreflection Conformance to coefficient of retroreflection requirements shall be determined instrumentally,in accordance with ASTM E-810"Test Method for CoeffiCient of Retroreflection of Retroreflective Sheeting."Per ASTM E-810,the values presented in Table 3-are averages of RA values obtained at 0°and 90°rotations. 2.5 Entrance Angularity Performance and Orientation 3M High Intensity Prismatic Reflective Sheeting Series 3930 has been designed to be an effective wide angle reflective sheeting regardless of its orientation On'the substrate or the ultimate orientation of the Sign after installation.However,because the efficiency of light return,from cube corner refleCtors is not equal.at all application Orientations;which is especially apparent at larger entrance angles,it is possible to get the widest entrance angle light return from a particular orientation-When high entrance angle(?50°)performance is required for a given Sign(e.g."keep right"symbols),it can be obtained easily by properly orientating the Sheeting on the completed Sign.In such situations,the completed sign should havethe Sheeting positioned at the CP orientation (downweb direction perpendicular to the road).When the flat side of the diamond(direction of diamond chain links)is vertical in the completed:Sign,Sheetingis said to be at a 0°orientation.When the"primary groove line"(or, flat side of the diamond shape)is horizontal on the completed Sign,the Sheeting is said to be eta 90°orientation. See Figure-i for details. te4 lir:=1:03:wra um= •• Figure1.Primary groove lines-used to define Sheeting orientation. Unless Sign locatiod and/or position calls for extra-wide entrance angularity performance or a-specific installation direction is required in a customer specification,Signs and applied copy(letters, arrows, borders,and shields)can be fabricated-and installed using the:application orientation that most efficiently utilizes the reflective Sheeting: Note:For multi-panel Signs,it is recommended that all background panels be sheeted such that the Sheeting direction is the same for all panels. 2.6 Printed Colors and Overlay Films When processed.according:te 3M recommendations,the coefficient of retroreflection of a.screen-printed transparent color on white Sheeting shall be not less than 70%of the RA value of the corresponding colored Sheeting presented in Table„3:White Sheeting covered with 3M ElectroCuirm Film Series 1170,when processed according to 3M recommendations,shall have a coefficient of retroreflection of not less than 100%of the value of the corresponding colored Sheeting,as presented in Table 3.The chromaticities and luminances of printed colors and overlay films shall conform to the specifications presented in Table 2. •, _ _ - 4 3MT"High Intensity Prismatic Reflective Sheeting Series 3930 May 2018 3 Physical Properties 3.1 Fabrication Lines The manufacture of prismatic Sheeting results in lines being present in the product,as shown in Figure 2. In prismatic Sheeting,these lines are slightly thicker than the seal pattern legs.Fabrication lines are noticeable in shop light but are not observable on the road,either in daylight or at night,under typical use conditions. Across the roll width Figure 2.Fabrication lines. 3.2 Adhesive Series 3930 Sheeting has a pressure-sensitive adhesive that is recommended for application at temperatures of 65°F(18°C)and:higher. 4 Sign Fabrication Methods 4.1 Application Series 3930 Sheeting should be applied to Sign substrates at temperatures of 65°F(18 C)and higher using any of the following methods: Mechanical squeeze roll applicator— refer to 3M Information Folder 1.4.Applications to extrusions that are edge wrapped require sufficient softening of the Sheeting.This can be accomplished by directing additional heat to the "next to last"edge roller.This practice may increase productivity and minimize cracking. Hand squeeze roll applicator—refer to 3M Information Folder 1.6. Background or complete Sign applications of Series 3930 Sheeting must be performed with a roll laminator,either mechanical or hand driven. 4.2 Hand Application Hand application is recommended for legend and copy only. Refer to 3M.Informetion Folder 1,5 for more details. Hand applications will show some visual irregularities which may be objectionable to aesthetically critical customers.These irregularities are more noticeable on darker colors.To obtain a uniform close-up-appearance,..a roll laminator must be used. All direct applied copy and border MUST be cut and squeegeed at all metal joints. 4.3 Splices Series 3930 Sheeting must be butt spliced when more than one piece of Sheeting is used on a single piece of substrate.Sheeting pieces should not touch one another.This is to prevent the buckling that can occur as Sheeting expands under extreme temperature and humidity conditions. S 3MT"High intensity Prisrnetic Reflective Sheeting Series 3930 May 2018 4.4 Double Faced Signs The Sheeting on the bottom side of a double faced Signcan be damaged if rolled through a squeeze roll applicator with an unprotected steel bottom roller.The use of a semi-soft flat sheet between the steel roller and the applied Sign face will provide protection from damage.A material such as a rubber mat,tag board,or cardboard is recommended: 5 Substrates For traffic Sign use,the substrates that have been found to be most reliable and durable are properly prepared aluminum sheets and extrusions.Users are urged to carefully evaluate adhesion and Sign durability properties of all other substrates.Other substrates suitable for secure and durable applications of Series 3930 Sheeting,have the following characteristics: • Clean • Smooth • Flat • Rigid • Dimensionally stable • Weather resistant • Non-porous • High surface energy(pass water break test) Referto lM_Itafforroation Folder 1.7 for surface preparation recommendations..Substrates with low surface energies may require additional preparation steps,such as flame treatment,mechanical abrasion,or use of adhesion promoters prior to Sheeting.application.Guide Sign extrusions may be edge wrapped. Flat panels and unwrapped extrusions must be carefully trimmed so that Sheeting sections on adjacent panels do not touch on assembled Signs. High intensity prismatic Sheeting has been designed primarily for application to flat substrates.Any application to a substrate with a radius of curvature of less than five inches should also be supported by rivets or bolts.Plastic substrates are not recommended where cold shock performance is required.Sign failures caused by substrate failures or improper surface preparations are not the responsibility of 3M. 6 Imaging High intensity prismatic Sheeting may be processed into traffic Signs using any of the imaging methods described below.3M assumes no responsibility for the failures of Sign face legends or backgrounds that have been processed with non-3M process colors or with matched component imaging materials.other than those listed below. 6.1 Digital Imaging 3M High Intensity Prismatic Reflective Sheeting Series 3930 is compatible with the HP Latex 360/365 printers in combination with HP 831/HP 871 Latex inks.This compatibility is backed with a 3M MCSTM Warranty and 3M MCS Warranty for Traffic when the printing guidelines in 3M Information Folder 1.18 are followed and 3M Electro.CutT Film 1170C Clear is applied over the finished graphics.See the"Limited Warranty"section of this document for more information on the MCS Warranties. 6.2 Screen Processing Series 3930.Sheeting may be screen processedinto traffic Signs using 3M Process Colors Series 8801 or Series 880N before or after being mounted onto a substrate.Series 8801 and 880N process colors can be screened at temperatures of 60-100°F(16-38°C)and at relative humidities of 20-50%.A P.E.157-screen mesh with a fill pass is recommended.Refer to 3M Information Folder 1.8 for details.Clear coating is neither required nor recommended. Use of process color series other than 8801 or 880N is not recommended. 6.3 3A11 ElectroCutlm Film 3M ElectroCut Film Series 1170 may be used on Series 3930 prismatic Sheeting to provide transparent colored background copy for traffic.control Signs.Refer to 3M Product Bulletin 1170 for fabrication procedures. 6 3MT"High Intensity Prismatic Reflective Sheeting Series 3930 May 2018 6.4 Applied Cut-Out Copy Series 3930 Sheeting cut-out copy may be applied to Sheeting backgrounds to create Sign legends.Such cut-out copy may be applied directly to the background Sheeting or in a demountable form.Direct applied copy must be cut at all panel seams and carefully trimmed back so that the Sheeting sections of adjacent panels do not touch one another on assembled Signs.Refer to 3;t1J-nfQrr. atiorLFolder 1~10 for more information. 7 Cutting Series 3930 Sheeting may be cut into letters and shapes with heights of at least 3 inches and stroke widths of at least%inch.Smaller sizes are not recommended.Sealing the cut edges of Series 3930 Sheeting is not required. 7.1 Plotter Cutting Programmable knife cut(electronic cutting): 1 Flat bed plotters can be used to either die cut or kiss cut Series 3930 Sheeting and offer the most consistent and reliable performances. 2 Friction fed plotters can be used to:kiss cut only.This is achieved using.600 grams of down force and a 60° cutting blade.Additional drive wheels may be needed to improve tracking.Alternatively,Series 3930 Sheeting can be cut from the liner side.To do so,the blade force and:knife depth must be set to score,but not cut through, the topfilm.After scoring,break apart individual copy or apply premask to retain spacing. 7.2 Other Cutting Methods Series 3930 Sheeting may be handout or die cut one sheet at a time,and band sawed or guillotined in stacks. Cutting equipment such as guillotines and metal shears,which place pressure plates on the Sheeting when cutting, may damage the optics.Padding the pressure plate and easing it down onto the sheets being cut will significantly reduce damage.Maximum stack height for cutting Series 3930 Sheeting is 1 Ya inches,.or 50 sheets.Cutting procedure details can be,found in 3M Information Folder 1.10. 8 Installation Nylon washers are required when twist style fasteners are used to mount Signs. 9 Shelf-Life, Storage, and Packaging Series 3930 Sheeting should be stored in a cool,dry area,preferably at 65-75°F(18-24°C)and 30-50%relative humidity,and applied within two years of date of manufacture.Rolls should be stored horizontally in their shipping cartons.Partially used rolls should be returned to their shipping cartons or suspended horizontally from rods or pipes through their cores. Unprocessed sheets should be stored flat.Finished Signs and applied blanks should be stored on edge. Screen processed Signs must be protected with SCW 568 slipsheet paper.Place the glossy side of the slipsheet against the Sign face and pad the face with closed cell packaging foam.Double faced Signs must have the glossy side of a piece of slipsheeting against each face of the Sign. Unmounted screened faces must be stored flat and interleaved with SCW 568 slipsheeting,glossy side against the Sign face. Avoid banding,crating, or stacking Signs. Package for shipment in accordance with commercially accepted standards to prevent movement and chafing.Store Sign packages indoors on edges. Panels and finished Signs must remain dry during shipment and storage.If packaged Signs become wet,unpack immediately and allow Signs to dry.Refer to 3M inferrnaliemEoldeall for instructions on packing for storage and shipment. • T 3MT"High intensity Prismatic Reflective Sheeting Series 3930 May 2019 10 Cleaning Signs that require cleaning should be flushed with water,then washed with a detergent solution and soft bristle brush or sponge.Avoid pressure that may damage Sign faces.Flush with water following washing;Do not use solvents to clean Signs. 11 Durability The durabilities of Series 3930 Sheeting and finished Signs made using 3M Matched Component materials will depend upon substrate selection and preparation,compliance with recommended application procedures, geographic area,exposure conditions, and maintenance practices. Maximum durabilityof Series 3930 Sheeting can be expected in applications subject to vertical exposures on stationary objects,when processed and applied to aluminum substrates prepared according to the recommendations provided in 3M information Folder 1.7.The user must determine the suitability of any nonmetallic Sign backing for its intended use.Sign failures caused by substrate failures or improper surface preparations are not the responsibility of 3M.Application'to unprimed, excessively rough or non-weather-resistant surfaces,or exposure to severe or unusual conditions can shorten the performance lifetime of Series 3930 Sheeting.3M process colors and ElectroCut"''' Film,when used according to 3M recommendations,are generally expected to produce Signs with performances comparable to those of their colored reflective Sheeting components.Custom colors,certain lighter colors,heavily toned colors,and blends containing yellow or gold may have reduced durabilities.Atmospheric conditions in certain geographic areas may result in reduced durability. Periodic Sign inspection and regular Sign replacement are strongly recommended in order to help Sign owners. establish their own effective service life expectations,beyond the warranty period. 12 Health and Safety Information Read all health hazard,precautionary,and first aid statements found in the Safety Data Sheets(SDS);Article Information Sheets,and products labels of any materials for important health,safety, and environmental information prior to handling or use.To obtain SDSs and Article Information Sheets for 3M products,go to 3M.com/SDS,contact 3M by mail,or for urgent requests call 1-800-364-3517, 13 Warranty Information 13.1 3M Basic Product Warranty and Limited Remedy 3M High Intensity Prismatic Reflective Sheeting Series 3930("Product")is warranted to be free of defects in materials and manufacture at the time of shipment and to meet the specifications stated in this Product Bulletin.If Series 3930 Sheeting is proven not to have met the Basic Warranty on its shipment date,then a buyer's exclusive remedy,and 3M's sole obligation,at 3M's option,will be refund or replacement of the Sheeting. 13.2 General Warranty Terms • 3M makes the Additional Warranty(as defined below)as to any traffic control and guidance Sign in the United States and Canada made with 3M High Intensity Prismatic Reflective Sheeting Series 3930 and the Matched.Component materials listed in Table 4,below.Any Additional Warranty is contingent on all components involved in the Additional Warranty being stored,applied,installed,and used only as 3M recommends in its.Product Bulletins and Other Product Information. • The Basic Warranty and any applicable Additional Warranty are collectively referred to as the"3M Warranty." • A Sign's failure to meet the 3M Warranty must be solely the result of the Product or the matched component materials'design or manufacturing defects.3M has no obligation under the 3M Warranty if a Sign failure is caused by(a)outside causes including improper fabrication,handling,packing,storing, shipping, maintenance,or installation;(b).use of any material or product not recommended by 3M in this product bulletin,in the 3M information folders and product bulletins listed in Section 15,or in applicable 3M Technical Memorandums;(c)use of application equipment not recommended by 3M;(d)failure of Sign substrate;(e)loss of adhesion due to incompatible or improperly prepared substrate;(f)exposure to chemicals,abrasion,or other mechanical damage;(g)snow burial or any other Sign burial;(h)collisions,. vandalism,or malicious mischief;or(i)an act of God. 8 3MT"High Intensity Prismatic Reflective Sheeting Series 3930 May 2018 • 3M reserves the right to determine method of replacement. • Any replacement Product or Sign restoration will carry the unexpired warranty of the Product it replaces. • Claims made under this warranty will be honored only if(a)the Sign was dated at the time of fabrication ("Fabrication Date")using a permanent method(sticker, marker,metal stamp,etc.), (b)3M is notified in writing of the claim within thirty days of discovery,(c)3M is provided with the information reasonably required to validate the claim,and(d)3M is permitted to verify the cause of the failure. • 3M is not responsible for any additional warranties that the Sign Manufacturer offers to its customers beyond the 3M Warranty. Table 4.Matched Component Materials - ':MatchedCoinponents_,= Process Colors Series 8801 Series 880N ElectroCutmt Film Series 1170 Premium Protective Series 1160 Overlay Film 13.3 Additional Warranty and Limited Remedy The Additional Warranty for a Sign made with the Product is that the Sign will:(a),remain effective for its intended use when viewed from a moving vehicle under normal day and night driving conditions by a driver with normal vision and(b)after cleaning,will meet the minimum coefficient of retroreflection value stated in Table 5 for the applicable Warranty Period,as measured from the Sign's Fabrication Date. Table 5.Minimum Percent of Initial RA(See Table 3)Retained for Applicable Warranty Period for White,Yellow, Red,Green,Blue,and Brown Sheeting n. Minimum Percentage Warranty�Perioa` s',;,- - 1-7 Years Q3' 85%a1tit1.: 8-10 Years 71%7"' • If any Sign made with the Product is proven not to have met the Additional Warranty,then a buyer's exclusive remedy,and 3M's sole obligation,at 3M's option is: • If this occurs within seven years Of the Fabrication Date,then 3M will,at its expense,restore the Sign's surface to its original effectiveness;.or • If this occurs during the remainder of the Additional Warranty Period,then 3M will furnish only the necessary Product and matched component materials quantities to restore the Sign's surface to its original effectiveness.. 13.4 Additional Warranty& Limited Remedy for 3934 Orange Product The Additional Warranty for a Sign made with 3934 orange Sheeting(Orange Product)is that the Sign will:(a) remain effective for its intended use when viewed from a moving vehicle under normal day and night driving conditions by a driver with normal vision;(b)after cleaning,will retain the coefficient of retroreflection stated in Table 6 for three years,as measured from Fabrication Date;and(c)after cleaning,the Product will maintain daytime luminance equal to or greater than the minimum value specified in Table 2. Table 6.Minimum Coefficient of Retroreflection for 3934 Orange Sheeting Product(cd/lux/m2)(0.2° observation angle and-4°entrance angle) Warrant'Period .Miiiimum.R :. 3 Years 80 If any Sign made with the Orange Product is proven not to have met the Additional Warranty,then a buyer's exclusive remedy,and 3M's sole obligation,at 3M's option,is that 3M will provide pro-rated replacement of the 3M materials. Refer to 3M Information Folders and Product Bulletins for detailed information about recommended application procedures and equipment. 9 3Mna High Intensity Prismatic Reflective Sheeting Series 3930 May 2018 13.5 Disclaimer THE 3M WARRANTY IS MADE IN LIEU OF ALL OTHER WARRANTIES OR CONDITIONS, EXPRESS OR IMPLIED, INCLUDING BUT NOT LIMITED TO ANY IMPLIED WARRANTY OR CONDITION OF MERCHANTABILITY,OR FITNESS FOR A PARTICULAR PURPOSE,OR ANY IMPLIED WARRANTY ARISING OUT OF A COURSE OF DEALING OR OF PERFORMANCE,CUSTOM, OR USAGE OF TRADE. 13.6 Limitation of Liability Except for the limited remedy stated above, and except where prohibited by law,3M will not be liable for any loss or damage arising from the Signs or any 3M product,whether direct, indirect,special,incidental,or consequential damages(including but not limited to lost profits,business,or revenue in any way),regardless of the legal theory asserted including warranty,contract,negligence,or strict liability. 14 Other Product Information Always confirm that you have the most current version of the applicable product bulletin, information folder,or other product information from 3M's Website at http://www.mmm.com/roadsafety. 15 Literature References 3M IF 1,4 Instructions for Interstate Squeeze Roll Applicator 3M IF 1.5 Hand Application Instructions 3M IF 1.6 Hand Squeeze Roll Applicator 3M LF1,7 Sign Base Surface Preparation 31V1AE_13 Process Colors Series 880 and 900 Instructions for Use 3M IF 1.10 Cutting, Premasking,and Prespacing 3M1E1,11 Sign Maintenance Management 3M IF 1.18 Digital Imaging with HP Latex 360/365 Printers on 3MTM Reflective Sheeting Series 4000 and 3930 3M_11` .5 Digital Imaging with HP Latex 360/365/370/375 Printer on 3MT° Reflective Sheeting Series 4000 and 3930 for Rigid Temporary Traffic Control Signing Applications 3M PB 8801 3MTM Process Color Series 8801 3M PB 880N 3M^' Process Color Series 880N 3M PB 116Q Premium Protective Overlay Film 3M PB 1170 3Mr" ElectroCutr" Film Series 1170 ASTM Test Methods are available from ASTM International,West Conshohocken,PA. For Information or Assistance Call: 1-800-553-1380 In Canada Call: 1-800-3M HELPS (1-800-364-3577) Internet: http://www.3M.com/roadsafety 3M,Science.Applied to Life.,and ElectroCut are trademarks of 3M.Used under license in Canada. 3M assumes no responsibility for any injury,loss,or damage arising out of the use of a product that is not of our manufacture.Where reference is made in literature to a commercially available product, made by another manufacturer,it shall be the user's responsibility to ascertain the precautionary measures for its use outlined by the manufacturer. Transportation Safety Division 3M Center,Building 0225-04-N-14 St.Paul,MN 55144-1000 USA Phone 1-800-553-1380 Please recycle.Printed in USA 6a 3M 2018. Web am_. ni'wHdsafgty All rights reserved.Electronic Only . . oavirod,„,6 Certified Analysis Trinity Highway Products LLC or 2548 RE.28th St. Order Number: 1328763 Prod In Grp: 0-0E2.0 Ft Worth(TilP),TK 76111 Phn:(817)665-1499 Customer PO: 69236 As of:8i25/20 . Customer: ZUMAR INDUSTRIES:INC-WA DM Number: 80956 Ship Date 12015 STEELE STREET SOUTH Document 0: 1 Shipped To: WA 111111111111Hillifi TACOMA,WA 98444 Use State: WA Project: STOCK Qty Part 0 Dacrliiticin Spec C./.. TY Heat Code/Heat illelt1 TS Elg C Mn P 8 St Cu Cti Cr Vu ACW . 250 7202220 /,600P512@12C1 - watE 569-9 DI 01 4 200 7202600 2.000P512@288 WIRE 5699 01 01 4 7202600 A-653 Ma A96737 70,000. 87,500 20:2 0.220 0.880 0.013 0.004 0.010 0.100 0.000 0,060 0.002 4 300 7202910 2.000PS14@120 A-653 Mo A97358 67.300 84.500 204 0.210 0,810 0.09 0.003 0:010 0.120 0.003 .0;050 0,003 4 7202910. WIRE 56990101 4% 350 72031150 2,000P514@144 WIRE 5699 01 01 4 7203050 A-653 Mo A973513 67,300 84,500 20.5 0.210 0.850 0.009 0.003 0.040 0.120 0.003 0.050 0.003 4 90 7204060 2,250P812@288 A•653 Mu A96I34 67.560 83,900 '24:7 0.210 0.850 0.011 0.004 0:030 0.100 0.000 0.060 0.003 4 7204060 WIRE 56990101 4 100 7208060 2.500PS12J1 92 WIRE 5699 01 01 4 7208060 A-653 Mo A93221 65.100 83,100' 25.6 0.190 0,800 0.007 0.001 0.030 0.120 0:000 0,050 0.001 4 40 7208150 • 2.500PS12(0288 A-653 Mo A93221 155,100 83,100 25.6 0.190 0.800 0.007 0.001 0.030 oazo 0,000 0.056 0.001 4 7208150 WIRE 5699 01 01 4 ALL STEEL FOR RAIL ELEMENTS SHALL CONFORM TO ASTM A 606 TYPE.4 OR ASTM A588 GRADE A ORB. 1 of 2 , 4 Certified Analysis AtAll 1\-2441111P14111-- Trinity Highway Products LLC 2548 N.E.28th St, Order Number: 1328763 Prod Ln Grp: 0-0E2.0 Ft Worth(THP),TX 7611 1 Phn:(817)665-1499 Customer PO; 69236 As o fi 11/25120 Customer: ZUMAR INDUSTRIES INC-WA BOL Number 80956 Ship Date: 12015 STERI.F STREET SOUTH Document#: 1 Shipped To: WA TACOMA,WA 9E144,1 Use State: WA 11111111 Project: STOCK Upon delivery,all materials subject to Trinity Highway Products,LLC Storage Stain Pnlluy QMS-LG-002. ALL STEEL USED WAS MELTED AND MANUFACTURED 1N USA AND COMPLIES WITH THE BUY A? RICA ACT,23 CFR 635.410. ALL GUARDRAIL MEETS AASIITO M-180,ALL STRUCTURAL STEEL MEETS ASTM A36 UNLESS OTHERWISE STATED. ALL COATINGS PROCESSES OF THE STEEL OR IRON ARE PERFORMED IN USA AND COMPLIES WITH THE"BUY AMERICA ACT",23 CFR 635.410. ALL GALVAN171aD MATERIAL CONFORMS WIT]I ASTM A-123(US DOMESTIC SHIPMENTS) ALL GALVANIZED MATERIAL CONFORMS WITH.ASITA A-123&ISO 1461(INTERNATIONAL SHIPMENTS) FINISHED GOOD PART NUMBERS ENDING IN SUFFIX 13,P,OR S,ARE UNCOATED BOLTS COMPLY WITH ASTM A-307 SPECIFICATIONS AND ARE GALVANIZED IN ACCORDANCE WITH ASTM UNLESS OTHERWISE STATED. NUTS COMPLY WITH ASTM A-563 SPECIFICATIONS AND ARE,GALVANIZED IN ACCORDANCE WITH ASTMA-I53,UNLESS OTHERWISE STATED, WASHERS COMPLY WITH ASTM F-436 SPECIFICATION AND/ORE-844 AND ARE GALVANIZED IN ACCORDANCE WITH ASTM F-2329,UNLESS OTHERWISE STATED. 3/4"DIA CABLE 6X19 ZINC COATED SWAGED END AISI C-1035 STEEL ANNFALED STUD 1"DIA AS114449AA,SIIT1)M30,TYPE II BREAKING STRENGTH-460110 LB State of Texas,County of Tenant.Sworn and subscribed before=this25th day of August,2020, T •ty lighw: Pnadue Notary Public: .40 Certified --,41111,73.•• 1-7.7"."1"1"1", Commission Expires: 410.; -'46 MELISSA GUTIERREZ 4-.47.0 Notary Public.State of Texas, 44441111°‘j. Ckt alip' Quality Assurarli illigdP7— 147 Comm.Expires 01-14-2023 IgigiW Notary ID 130D78834 2 of 2 , • .1 .... _ _ .... , , . ..., . my, * 4iwo CI) mtill 0 , , 0 sit p ........ ,„ cp. = . cn 4, 000.4: ••, ,,,', ,,-f...:4134.1.. .. .....„, .,:-...,.-",•Po'.,"" '.. :4,:- ‘ C ai \ 41111 . 6 , *OP Ci) .t.... °C3 . 40' CIO Cd0 • ' • * SUBMITTAL REVIEW „,,.....? * 0 • 4 X No Exceptions Taken . . . .. , . ., ..... Make Corrections Noted , ' ow. C 1 I • 4 Amend &Resubmit tf Rejected-See Remarks • Al 0 MMI 0 # IMPORTANT NOTICE.This review ."" • A, • * — ' does not relieve the Contractor from "Ilk .,,, , '1'4- ' i I : 04, . S. AL_ CreosnPOtrancstibpilocuity tornen comply&confomi with the Plans, Specifications.and 111101-1.-* ... , t,ss,:a., •_, . . , - . ,i • -.., Fa I k t I .' Ili E. . • a . • . . • . • . . (;rviky *Cl.horrie,Isw.. 7 ORS •_____ ,,,j: 9/30/21 ,. , 0.- , 1. .._.. . ,l.k . , • sciR_Loc TM TRINITY Perforated Traffic Post r Ahead of the Curve T M SQRLOC M DURABLE VALUE Perforated Traffic Holes Telescoping Properties Post All four sides feature holes that shall be 7/16" The finished post shall be straight and have a diameter, (i1/64')on one-inch centers through smooth, uniform finish. All consecutive sizes of Material the entire length of the post. Holes shall be on square tubes shall telescope freely and for not Steel posts furnished shall conform to ASTM the centerline of each side, in alignment with and less than ten feet of their length without the need A653 Grade 50, Standard Specification for opposite each other directly and diagonally. to match any particular face to any other face. Steel Sheet, Zinc Coated(Galvanized)or All holes and ends shall be free from burrs. Zinc-Iron Alloy Coated (Galvanneaied) by the Hot-Dip Process, Specifications Shape Nominal Available Squareness Twist Outside Tolerances Outside Gauges Tolerance Permissible at Corners The cross section on the post shall be Dimension in 3' Length (Ali Sides; carbon steel tube formed to square and (7.1 1. 1.3 i4'1 '1 2 109 1 14 i'11,2,1'. welded directly in the corner by high 1-1/2" x 1-1/2 X t .009" 050' t .006' frequency electric resistance welding and externally scarfed to match the corner radii. + , Wow 'ncx-.1.---? x .tr X X -, i, . + .012" 06"-, 062" 00i" F ±.008" .....,A_8_ _x. X 062' ± .010 i L:'., ' Finish The galvanized part will conform to ASTM 2-1/2" x 2-1/2' , X x _ ' .0-5" I 075' ± .010' A653, G90, Structural Quality, Grade 50. The corner weld is zinc coated after scarfing. Outside Dimensions: Measurements are made at least 2" from the end of the tube. The galvanized post has a minimum of 0.5 Wall Thickness: Permissible variation in wall thickness is +.011", -.005". mil of clear acrylic polymer coating applied Length: The length of each post shall have a permissible length tolerance of± 1/4'. as a rust preventative. Convexity and Concavity: As measured in the center of the flat sides, shall not exceed± .010", determined at the corner. Corner Radii: Standard outside radii shall be 5/32",with variation of± 1/32". Straightness: Permissible variation in straightness is 3/16' in a 10 foot section. SQR-LOC TIM Square Traffic Post astributeci by. TRINITy , ..,. www.trinityhighway.com HIGHWAY 1 .888.323.6374 Copyright?,2014 Trinity Highway.AD Rights Reserved. • Date:5212021 To:Northwest Steel 1"1 LJ C®R e228 W.7471-1 8TR ET httpa://www.nucortubulor.com CHICAGO,IL 60838 https://www.ntpportal.com TUBULAR PRODUCTS Tel:708-498.0380 Fax:708-563-1950 Certificate Number: CHI 524044 Sold By: Purchase Order No:16181 NUCOR TUBULAR PRODUCTS INC. Sales Order No:CHI 305362-7 CHICAGO DIVISION Bill of Lading No:CHI 185616-5 Shipped:2/5/2021 6226 W 74TH STREET Invoice No:CHI 413551-4 Invoiced:2/5/2021 CHICAGO,IL 60638 Tel:708 496-0380 Fax:708 563-1950 Sold To: Ship To: 1411-NORTHWEST STEEL&PIPE 1-NORTHWEST STEEL&PIPE(RAIL) P.O.BOX 11247 4802 SOUTH PROCTOR STREET TACOMA.WA 98411 BN TRACK 532 SPIN#050824 TACOMA,WA 98409 CERTIFICATE of ANALYSIS and TESTS Certificate No:CHI 524044 Customer Part No: Test Date:1/2512021 TUBBIG A500 GRADE B(C) Total Pieces Total Weight Lbs 2-1l2"SG X 3/16"X 40' 100 22,360 Bundle Tag Mill Heat Specs YfT Ratio Pieces Weight the 118450 4N 204007 YLD.57400/TEN=64077lELG=26.32 0.8958 25 5,590 118451 4N 204007 YLD=57400FTEN=64077/ELG=26.32 0.8958 25 5,590 118452 4N 204007 YLD=57400/TEN44077/ELG=26.32 0.8958 25 5,590 118453 4N 204007 YLD=57400/TEN-64077/ELG26.32 0.8958 25 5,590 Mill#:4N Heat#:204007 Carbon Eq: 0.3276 Heat Src Origin:MELTED AND MANUFACTURED IN THE USA C Mn P S Si ' Al Cu Cr Mo V _ Ni Nb Sn 0.2000 0.5500 0.0070 0.0040 0.0180 ' 0.0310 'T410 0.0880 0.0210 0.0040 0.0500 0.0010 0.0090 N Ti Sb 0.0070 0.0010 0.0010 LEED Information(based on the most recent LEED information from the producing mil) Method Location Recycled Content Post Consumer Post Industrial EAF Crawfordsville,IN • 74,5% 27.1%' 47.4% Certification: I certify that the above results are a true and correct copy of records prepared and maintained by NUCOR TUBULAR PRODUCTS INC.Sworn this day,1/25/2021, THE SPECIFICATIONS LISTED BELOW REPRESENT THE SUBMITTAL REVIEW CURRENT ISSUED DATES OF THESE STANDARDS.THIS DOES NOT INDICATE THAT THE MATERIAL ABOVE CONFORMS TO EACH OR ALL OF THE STANDARDS.WE CERTIFY THE No Exceptions Taken MATERIAL ABOVE TO THE SPECIFICATION LISTED IN THE Make Corrections Noted rt LINE DESCRIPTION. X Amend & Resubtldt CURRENT STANDARDS: Retected-See Remarks A252-19 IMPORTANT NOTICE This review A5001A500M-20 does not relieve the Contractor from ASTM AS3 -20 responsibility to comply&conform ASTM A53/A53M-181 ASME SA-53/SA-53M-18 A8471A847M-14 with the Plans. Specifications, and A1085/A1085M-15 Contract Documents. IN COMPLIANCE WITH EN 10204 SECTION 4.1 INSPECTION CERTIFICATE TYPE 3.1 C;nag efeborne,�m �ANEU.7WG ENGINEERS Provide clarification on use of 2-1/2" Square tubing. By: MB Date: 9/20/21 Please note, lower sign support shall be hot-dip galv, per Std. Plan - 129. Page-1 Simi Fast Page I of I VCB240 - Corner Bolt VCB240 PRODUCT DESCRIPTION A bent bolt designed to attach a sign to square tubing or to attach a square tube post to a square tube anchor. FEATURES AND BENEFITS Compound Bend Consists of two 45 degree bends rather then a 90 degree radius. Easier to pass through a telescop tubing. Can't Be Rotated Tamper resistant when used with a Vandlgrad Nut. Steel Zinc Plate Good strength&corrosion protection. Bolts are Packed in Bags of 100 Better inventory control. Lot Number on Each Bag of Bolts Traceables to raw material. TECHNICAL • ; • Materia1:14-0-14"1- ASTM A30T Steel Diameter:5/16-18 SUBMITTAL REVIEW Length: 2"-3 No Exceptions Taken Make Corrections Noted -X— Amend & Resubmit Reiected-See Remarks IMPORTANT NOTICE.This review does not relieve the Contractor from responsibility to comply&conform with the Plans, Specifications, and Contract Documents (.3ireiy osticome, CON..% TIPC,ENGINEERS By, DRS Date. 9/22/21 http://w1m.simifast.com/detaikorner-boleprint 11/22/201 7 01/13/2020 06:52 12535813131 NW FASTENER PAGE 81 Northwest Fasteners Inc. 15127 Washington Aye S.W. Lakinvooti Washiwgeon 911490 MTN-KATT OF PHYSICAL CONFORMANCE January 7,2020 CUSTOMER NAME: ZUMAR Seller warrants that Matcrial furnished on INVOICE/0 I t2024 and your P.0.0065728 meets the following physical requirements: ITEM 01 318-I 6 X 3 HEX BOLTS ASTM A307—GALVANIZED A153(AASHTO M-232) SUBMITTAL REVIEW X No Exceptions Taken AMES W OLSON Make Corrections Noted PRESIDENT Amend &Resubmit Rejected-See Remarks IMPORTANT NOTICE:This review does not relieve the Contractor from responsibility to comply&conform with the Plans. Specifications, and Contract Documents. 415ka 4r...irony az 011LOTEIle,LICA CONSULTING ENGINEERS By: MB Date: 9/20/21 PHONL 253-5112-1671/000-562-4170 FAX:253-501-3131 Northwest Fasteners Inc. 15127 Washington Ave S.W. Lakewood Washington 98498 CERTIFICATE OF PHYSICAL CONFORMANCE December 14. 2020 CUSTOMER NAME:ZUMAR Seller warrants that material furnished on thirYOJCI# 184802 and your P.O.#70339 meets the following physical requirements: ITEM 01 3/8 USS FLAT WASHERS-GALVANIZED ASTM F 2329(AASHTO M-232) SUBMITTAL REVIEW X No Exceptions Taken Make Corrections Noted JAMES W OLSON PR FSEDENT Amend & Resubmit Rejected-See Ren-iarks IMPORTANT NOTICE This review does not relieve the Contractor from responsibility to comply&confomi with the Plans, Specifications, and ; Contract Documents. Griiy dr Oshorive, 1.100• CONSULTING ENGINEERS By MB Date: 9/20/21 PHONE 253-582-1671/800-562-4170 FAXI53-581-3131 • Northwest Fasteners Inc. • 15127 Washington Ave S w, Lakewood Washington 98498 C ER 1 If IC ATE OF PHYSICAL CONFORMANCE August 30,2018 CUSTOMER NAME:ZUMAR Seller warrants that material furnished on INVOICES, 178375 and your p,O,#41272 meets the following physical requirements: ITEM#1 31 SPLIT LOCK WASHERS ANSI R27.I-GAVLVANIZED ASTM A153(AASHTO M-232( AMES W OLSON PRESIDENT SUBMITTAL REVIEW X No Exceptions Taken PHONE:253-552-1671/Soo-562.417o _ Make Corrections Noted X:253-581.3131 Amend& Resubmit Rejected-See Remarks IMPORTANT NOTICE This review does not relieve the Contractor from responsibility to comply&conform with the Plans, Specifications, and Contract Documents. gala (;Itsy&O .crane,Itrica CONSULTING ENGINEERS By: MB.. Date: 9/20/21 Northwest Fasteners Inc. 15127 4tashungton Ave S.W. Lakewood Washi'won 98498 CERTIFICATE Of PHYSICAL CONFORMANCE August 30.2018 CUSTOMER NAME:LUMAR Seller warrants that material furnished on INVOIGE# 178714 and your P.O.1061471 meets the following physical requirements- ITEM#8 3/8-16 SAE 1955 GRADE 2 FINISHED HEX NUTS-GALVANIZED ASTM A153(AASHTO M-232) JAMES W OLSON PRESIDENT SUBMITTAL REVIEW X No Exceptions Taken Make Corrections Noted PHONE 253-582-1671/800-562-4170 Amend &Resubmit FAX:253-581.3131 Rejected-See Remarks IMPORTANT NOTICE This review does not relieve the Contractor from responsibility to comply&,conform with the Plans. Specifications_and Contract Documents. CIrswy.&Osiwaryte,Lan. OONauco a ENGINEERS By MB Date: 9/20/21