HomeMy WebLinkAboutOn Hold Letter Final May 27, 2025 Doan Nguyen SUBJECT: "On Hold" Notice NgocChan Final Short Plat/ LUA25-000029 Dear Doan, The Development Engineering Division of the City of Renton accepted the above master application for review on May 6th, 2025. During our review, staff has determined that is necessary in order to proceed further. The following comments will need to be addressed and documents re-submit before we may continue the review of the above subject application: • Redline comments requiring corrections can be found at the City’s File Transfer Portal (FTP) site available at the following link and are attached for reference: https://fileshare.rentonwa.gov:8443/?ShareToken=27DAF96FFDE36628DBF7FBD11363440729A1A9DA Note: the link will expire in 30 days, contact me if a new link is needed or see the attached comment summary. At this time, your project has been placed “on hold” pending receipt of the requested information. The maximum time for resubmittal shall be within ninety (90) days of this notice. Please contact me at 425-430-7384 or hhuynh@rentonwa.gov if you have any questions. Sincerely, Huy Huynh Project Manager cc: Doan Nguyen / Owner(s) Doan Nguyen / Applicant Markup Summary Subject: Stamp Page Index: 3 Color: File Name: L_LND20-0658_Declaration of Covenant_Drainage Facilities and On-Site BMPs.pdf L_LND20-0658_Declaration of Covenant_Drainage Facilities and On-Site BMPs.pdf (4) Subject: Cloud+ Page Index: 6 Color: File Name: L_LND20-0658_Declaration of Covenant_Drainage Facilities and On-Site BMPs.pdf text is too small - must be 8 point font size or larger. Please use Typical Full Infiltration Application pages provided with City comments. Subject: Line Page Index: 7 Color: File Name: L_LND20-0658_Declaration of Covenant_Drainage Facilities and On-Site BMPs.pdf Subject: Line Page Index: 7 Color: File Name: L_LND20-0658_Declaration of Covenant_Drainage Facilities and On-Site BMPs.pdf Subject: Cloud+ Page Index: 2 Color: File Name: MAP_LND20-0658_SHORT PLAT MAP.pdf CRAIG MAP_LND20-0658_SHORT PLAT MAP.pdf (10) Subject: Cloud+ Page Index: 2 Color: File Name: MAP_LND20-0658_SHORT PLAT MAP.pdf 20170524001480 (title report has wrong # - see actual document) Subject: Line Page Index: 2 Color: File Name: MAP_LND20-0658_SHORT PLAT MAP.pdf Subject: Line Page Index: 2 Color: File Name: MAP_LND20-0658_SHORT PLAT MAP.pdf Subject: Cloud+ Page Index: 3 Color: File Name: MAP_LND20-0658_SHORT PLAT MAP.pdf previously indicated that encroaching fence was going to be removed and fence replaced. Please confirm. If not, how will fence be handled? TYPICAL FULL INFILTRATION APPLICATIONS 6" 24"12" 24" WASHED ROCK 1 12"- 34"LEVEL INFILTRATION TRENCH SECTION ANTS PLAN VIEWNTS SECTION VIEWNTS VARIES A A 6"6" 4" RIGID OR 6"FLEXIBLEPERFORATEDPIPE CB SUMP w/SOLID LID ROOF DRAIN 4" RIGID OR 6" FLEXIBLEPERFORATED PIPE OVERFLOWSPLASH BLOCK ROOF DRAIN CB SUMP w/SOLID LID 12" FINE MESHSCREEN SETBACKFROMBUILDING5' MIN. 1' MIN.1' MIN. FILTER FABRICCOMPACTED BACKFILL 4" RIGID OR 6" FLEXIBLEPERFORATED PIPE112" - 34" WASHED ROCKMIN. 1' ABOVE SEASONALHIGH GROUNDWATERTABLE, SEE SECTION C.2.2.2 TRENCH SETBACK FROMBUILDING AS REQUIRED,15' MIN. DRIVEWAY X-SECTIONNTS 2' MIN. FILTER STRIPSEE SECTIONS6.3.4 & 6.3.5 18" MIN. 6" MIN.3/4" TO 1-1/2"WASHED DRAINROCK GRASS OVERFLOW NOTE:SEE C.2.2.3 FORTRENCH LENGTHS,TRENCH SPACING ANDSITE LIMITATIONS MIN. 1' ABOVESEASONAL HIGHGROUNDWATERTABLE, SEESECTION C.2.2.2 X-SECTIONNTS GRASS 2' MIN. 18" MIN. 6" MIN.3/4" TO 1-1/2"WASHED DRAINROCK OVERFLOW 15' MIN. ASREQUIRED,SEE C.2.2.3 FROM ROOF NS T T S MIN. 1' ABOVESEASONAL HIGHGROUNDWATERTABLE, SEESECTION C.2.2.2 HOUSE FLOW 48 INCH DIAMETERHOLE FILLED WITH1 12" - 3" WASHEDDRAIN ROCK SECTIONNTS MARK CENTER OF HOLEWITH 1" CAPPED PVCOR OTHER MEANSFLUSH WITH SURFACEROOF DOWNSPOUTOVERFLOWSPLASH BLOCK TOPSOIL FINE MESH SCREEN MIN. 4" DIA.PVC PIPE SIDES OF HOLELINED WITHFILTER FABRICCATCH BASIN(YARD DRAIN) 15' MIN. AS REQUIRED, SEE SECTION C.2.2.3 VARIES 1' MIN. MIN. 1' ABOVE SEASONALHIGH GROUNDWATER TABLE,SEE SECTION C.2.2.2 5' MIN. SETBACKFROM BUILDING FLOW PLAN VIEWNTS HOUSE ROOFDOWNSPOUT ROOFDOWNSPOUT CATCH BASIN(YARD DRAIN) 48 INCH DIAMETERHOLE FILLED WITH1 12" - 3" WASHEDDRAIN ROCK text is too small - must be 8 point font size or larger.Please use Typical Full Infiltration Applicationpages provided with City comments. plan (CHE grav plan (CHEC grave CRAIG 20170524001480 (title report has wrong # -see actual document) previously indicatedthat encroachingfence was going tobe removed andfence replaced.Please confirm. Ifnot, how will fencebe handled? Subject: Cloud+ Page Index: 3 Color: File Name: MAP_LND20-0658_SHORT PLAT MAP.pdf previously indicated that encroaching fence was going to be removed and fence replaced. Please confirm. If not, how will fence be handled? Subject: Cloud+ Page Index: 3 Color: File Name: MAP_LND20-0658_SHORT PLAT MAP.pdf delete decimal point Subject: Cloud+ Page Index: 3 Color: File Name: MAP_LND20-0658_SHORT PLAT MAP.pdf Please confirm #. 3729 is at intersection of SE 172nd and Benson Rd S. Or, please show 3729 in correct location. Subject: Cloud+ Page Index: 3 Color: File Name: MAP_LND20-0658_SHORT PLAT MAP.pdf please add COR monument No. if applicable Subject: Cloud+ Page Index: 3 Color: File Name: MAP_LND20-0658_SHORT PLAT MAP.pdf please show a tie to one of these or another COR Monument. (Need 2 ties) previously indicated that encroaching fence was going to be removed and fence replaced.Please confirm. If not, how will fence be handled? delete decimal point Please confirm #. 3729 is at intersection of SE 172nd and BensonRd S. Or, please show 3729 in correct location. please add COR monument No. if applicable please show a tie to one of these oranother CORMonument. (Need 2 ties)