May 27, 2025
Doan Nguyen
SUBJECT: "On Hold" Notice
NgocChan Final Short Plat/ LUA25-000029
Dear Doan,
The Development Engineering Division of the City of Renton accepted the above master application for review on
May 6th, 2025. During our review, staff has determined that is necessary in order to proceed further.
The following comments will need to be addressed and documents re-submit before we may continue the review
of the above subject application:
• Redline comments requiring corrections can be found at the City’s File Transfer Portal (FTP) site available
at the following link and are attached for reference:
https://fileshare.rentonwa.gov:8443/?ShareToken=27DAF96FFDE36628DBF7FBD11363440729A1A9DA
Note: the link will expire in 30 days, contact me if a new link is needed or see the attached comment
summary.
At this time, your project has been placed “on hold” pending receipt of the requested information. The maximum
time for resubmittal shall be within ninety (90) days of this notice. Please contact me at 425-430-7384 or
hhuynh@rentonwa.gov if you have any questions.
Sincerely,
Huy Huynh
Project Manager
cc: Doan Nguyen / Owner(s)
Doan Nguyen / Applicant
Markup Summary
Subject: Stamp
Page Index: 3
Color:
File Name: L_LND20-0658_Declaration of
Covenant_Drainage Facilities and On-Site BMPs.pdf
L_LND20-0658_Declaration of Covenant_Drainage Facilities and On-Site BMPs.pdf (4)
Subject: Cloud+
Page Index: 6
Color:
File Name: L_LND20-0658_Declaration of
Covenant_Drainage Facilities and On-Site BMPs.pdf
text is too small - must be 8 point font size or
larger. Please use Typical Full Infiltration
Application pages provided with City comments.
Subject: Line
Page Index: 7
Color:
File Name: L_LND20-0658_Declaration of
Covenant_Drainage Facilities and On-Site BMPs.pdf
Subject: Line
Page Index: 7
Color:
File Name: L_LND20-0658_Declaration of
Covenant_Drainage Facilities and On-Site BMPs.pdf
Subject: Cloud+
Page Index: 2
Color:
File Name: MAP_LND20-0658_SHORT PLAT MAP.pdf
CRAIG
MAP_LND20-0658_SHORT PLAT MAP.pdf (10)
Subject: Cloud+
Page Index: 2
Color:
File Name: MAP_LND20-0658_SHORT PLAT MAP.pdf
20170524001480
(title report has wrong # - see actual document)
Subject: Line
Page Index: 2
Color:
File Name: MAP_LND20-0658_SHORT PLAT MAP.pdf
Subject: Line
Page Index: 2
Color:
File Name: MAP_LND20-0658_SHORT PLAT MAP.pdf
Subject: Cloud+
Page Index: 3
Color:
File Name: MAP_LND20-0658_SHORT PLAT MAP.pdf
previously indicated that encroaching fence was
going to be removed and fence replaced. Please
confirm. If not, how will fence be handled?
TYPICAL FULL INFILTRATION APPLICATIONS
6"
24"12"
24"
WASHED ROCK 1 12"- 34"LEVEL
INFILTRATION TRENCH
SECTION ANTS
PLAN VIEWNTS
SECTION VIEWNTS
VARIES
A
A
6"6"
4" RIGID OR 6"FLEXIBLEPERFORATEDPIPE
CB SUMP w/SOLID LID ROOF DRAIN
4" RIGID OR 6" FLEXIBLEPERFORATED PIPE
OVERFLOWSPLASH BLOCK
ROOF DRAIN
CB SUMP w/SOLID LID
12"
FINE MESHSCREEN
SETBACKFROMBUILDING5' MIN.
1' MIN.1' MIN.
FILTER FABRICCOMPACTED BACKFILL
4" RIGID OR 6" FLEXIBLEPERFORATED PIPE112" - 34" WASHED ROCKMIN. 1' ABOVE SEASONALHIGH GROUNDWATERTABLE, SEE SECTION C.2.2.2
TRENCH SETBACK FROMBUILDING AS REQUIRED,15' MIN.
DRIVEWAY
X-SECTIONNTS
2' MIN.
FILTER STRIPSEE SECTIONS6.3.4 & 6.3.5
18" MIN.
6" MIN.3/4" TO 1-1/2"WASHED DRAINROCK
GRASS
OVERFLOW
NOTE:SEE C.2.2.3 FORTRENCH LENGTHS,TRENCH SPACING ANDSITE LIMITATIONS
MIN. 1' ABOVESEASONAL HIGHGROUNDWATERTABLE, SEESECTION C.2.2.2
X-SECTIONNTS
GRASS
2' MIN.
18" MIN.
6" MIN.3/4" TO 1-1/2"WASHED DRAINROCK
OVERFLOW
15' MIN. ASREQUIRED,SEE C.2.2.3
FROM ROOF
NS T T S
MIN. 1' ABOVESEASONAL HIGHGROUNDWATERTABLE, SEESECTION C.2.2.2
HOUSE
FLOW
48 INCH DIAMETERHOLE FILLED WITH1 12" - 3" WASHEDDRAIN ROCK
SECTIONNTS
MARK CENTER OF HOLEWITH 1" CAPPED PVCOR OTHER MEANSFLUSH WITH SURFACEROOF DOWNSPOUTOVERFLOWSPLASH BLOCK TOPSOIL
FINE MESH SCREEN
MIN. 4" DIA.PVC PIPE
SIDES OF HOLELINED WITHFILTER FABRICCATCH BASIN(YARD DRAIN)
15' MIN. AS REQUIRED, SEE SECTION C.2.2.3
VARIES
1' MIN.
MIN. 1' ABOVE SEASONALHIGH GROUNDWATER TABLE,SEE SECTION C.2.2.2
5' MIN. SETBACKFROM BUILDING
FLOW
PLAN VIEWNTS
HOUSE
ROOFDOWNSPOUT
ROOFDOWNSPOUT
CATCH BASIN(YARD DRAIN)
48 INCH DIAMETERHOLE FILLED WITH1 12" - 3" WASHEDDRAIN ROCK
text is too small - must be 8 point font size or larger.Please use Typical Full Infiltration Applicationpages provided with City comments.
plan (CHE
grav
plan (CHEC
grave
CRAIG
20170524001480
(title report has wrong # -see actual document)
previously indicatedthat encroachingfence was going tobe removed andfence replaced.Please confirm. Ifnot, how will fencebe handled?
Subject: Cloud+
Page Index: 3
Color:
File Name: MAP_LND20-0658_SHORT PLAT MAP.pdf
previously indicated that encroaching fence was
going to be removed and fence replaced. Please
confirm. If not, how will fence be handled?
Subject: Cloud+
Page Index: 3
Color:
File Name: MAP_LND20-0658_SHORT PLAT MAP.pdf
delete decimal point
Subject: Cloud+
Page Index: 3
Color:
File Name: MAP_LND20-0658_SHORT PLAT MAP.pdf
Please confirm #. 3729 is at intersection of SE
172nd and Benson Rd S. Or, please show 3729 in
correct location.
Subject: Cloud+
Page Index: 3
Color:
File Name: MAP_LND20-0658_SHORT PLAT MAP.pdf
please add COR monument No. if applicable
Subject: Cloud+
Page Index: 3
Color:
File Name: MAP_LND20-0658_SHORT PLAT MAP.pdf
please show a tie to one of these or another COR
Monument. (Need 2 ties)
previously indicated
that encroaching
fence was going to
be removed and
fence replaced.Please confirm. If
not, how will fence
be handled?
delete decimal point
Please confirm #.
3729 is at
intersection of SE
172nd and BensonRd S. Or, please
show 3729 in
correct location.
please add COR
monument No. if
applicable
please show a tie to
one of these oranother CORMonument. (Need 2