Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
L_RSD Transportation Expansion_DOC_250521_v3
Page 1 of ___ Return Address: City Clerk’s Office City of Renton 1055 S Grady Way Renton, WA 98057 DECLARATION OF COVENANT FOR INSPECTION AND MAINTENANCE OF DRAINAGE FACILITIES AND ON-SITE BMPS Grantor: Grantee: City of Renton, a Washington municipal corporation Legal Description: Assessor's Tax Parcel ID#: IN CONSIDERATION of the approved City of Renton (check one of the following) Residential Building Permit Commercial Building Permit Clearing and Grading Permit Civil Construction or Utility Permit for Permit(s)_____________________ (Construction/Building/Utility Permit #) relating to the real property ("Property") described above, the Grantor(s), the owner(s) in fee of that Property, hereby covenants (covenant) with the City of Renton (“City of Renton” or “City”), a municipal corporation of the state of Washington, that he/she (they) will observe, consent to, and abide by the conditions and obligations set forth and described in Paragraphs 1 through 9 below with regard to the Property, and hereby grants (grant) an easement as described in Paragraphs 2 and 3. Grantor(s) hereby grants (grant), covenants (covenant), and agrees (agree) as follows: 1.The Grantor(s) or his/her (their) successors in interest and assigns ("Owners ") shall at their own cost, operate, maintain, and keep in good repair, the Property's drainage facilities constructed as required in the approved construction plans and specifications __________________ (Project Plan #) on file with the City of Renton and submitted to the City of Renton for the review and approval of permit(s) _____________________________ (Construction/Building/Utility Permit #). The Property's drainage facilities are shown and/or listed on Exhibit A – Site Plan. The Property’s drainage facilities shall be maintained in compliance with the operation and maintenance schedule included and attached herein as Exhibit B – Operations and Maintenance. Drainage facilities include pipes, channels, flow control facilities, water quality facilities, on-site best management practices (BMPs) and other engineered structures designed to manage and/or Page 2 of ___ treat stormwater on the Property. On-site BMPs include dispersion and infiltration devices, bioretention, permeable pavements, rainwater harvesting systems, tree retention credit, reduced impervious surface footprint, vegetated roofs and other measures designed to mimic pre-developed hydrology and minimize stormwater runoff on the Property. 2.City of Renton shall have the right to ingress and egress over those portions of the Property necessary to perform inspections of the stormwater facilities and BMPs and conduct maintenance activities specified in this Declaration of Covenant and in accordance with the Renton Municipal Code. City of Renton shall provide at least thirty (30) days written notice to the Owners that entry on the Property is planned for the inspection of drainage facilities. After the thirty (30) days, the Owners shall allow the City of Renton to enter for the sole purpose of inspecting drainage facilities. In lieu of inspection by the City, the Owners may elect to engage a licensed civil engineer registered in the state of Washington who has expertise in drainage to inspect the drainage facilities and provide a written report describing their condition. If the engineer option is chosen, the Owners shall provide written notice to the City of Renton within fifteen (15) otice of inspection. Within thirty (30) days of giving this report to the City of Renton. If the report is not provided in a timely manner as specified above, the City of Renton may inspect the drainage facilities without further notice. 3.If City of Renton determines accordance with Paragraph 2, that maintenance, repair, restoration, and/or mitigation work is required to be done to any of the drainage facilities, City of Renton shall notify the Owners of the specific maintenance, repair, restoration, and/or mitigation work (Work ) required pursuant to the Renton Municipal Code. The City shall also set a reasonable deadline for the Owners to complete th the Work. After the deadline has passed, the Owners shall allow the City access to re-inspect the Work. If the Work is not completed within the time frame set by the City, the City may initiate an enforcement action and/or perform the Work and hereby is given access to the Property for such purposes. intention to perform such Work. This Work will not commence until at least seven (7) days after such notice is mailed. If, within the sole discretion of the City, there exists an imminent or present danger, the seven (7) day notice period will be waived and Work will begin immediately. 4.The Owners shall assume all responsibility for the cost of any Work, or any measures taken by the City to address conditions as described in Paragraph 3. Such responsibility shall include reimbursement to the City within thirty (30) days of the receipt of the invoice for any such Work performed. Overdue payments will require payment of interest at the maximum legal rate allowed by RCW 19.52.020 (currently twelve percent (12%)). If the City initiates legal action to enforce this agreement, the prevailing party in such action is entitled to recover reasonable 5.The Owners are required to obtain written approval from City of Renton prior to filling, piping, cutting, or removing vegetation (except in routine landscape maintenance) in open vegetated stormwater facilities (such as swales, channels, ditches, ponds, etc.), or performing any alterations or modifications to the drainage facilities referenced in this Declaration of Covenant. Page 3 of ___ 6.Any notice or consent required to be given or otherwise provided for by the provisions of this Agreement shall be effective upon personal delivery, or three (3) days after mailing by Certified Mail, return receipt requested. 7.With regard to the matters addressed herein, this agreement constitutes the entire agreement between the parties, and supersedes all prior discussions, negotiations, and all agreements whatsoever whether oral or written. 8.This Declaration of Covenant is intended to protect the value and desirability and promote efficient and effective management of surface water drainage of the real property described above, and shall inure to the benefit of all the citizens of the City of Renton and its successors and assigns. This Declaration of Covenant shall run with the land and be binding upon Grantor(s), and Grantor's(s') successors in interest, and assigns. 9.This Declaration of Covenant may be terminated by execution of a written agreement by the Owners and the City that is recorded by King County in its real property records. IN WITNESS WHEREOF, this Declaration of Covenant for the Inspection and Maintenance of Drainage Facilities is executed this _____ day of ____________________, 20_____. GRANTOR, owner of the Property GRANTOR, owner of the Property STATE OF WASHINGTON ) COUNTY OF KING )ss. On this day personally appeared before me: , to me known to be the individual(s) described in and who executed the within and foregoing instrument and acknowledged that they signed the same as their free and voluntary act and deed, for the uses and purposes therein stated. Given under my hand and official seal this _____ day of ___________________, 20_____. Printed name Notary Public in and for the State of Washington, residing at My appointment expires Damien Pattenaude Superintendent Renton School District No. 403 X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X SD SD SD SD SD SD SD 39 FILTERRA WATER QUALITY TREATMENT UNIT EXHIBIT A - SITE PLAN Page 5 of 4 N 5TH ST PA R K A V E N AMENDED SOIL AT ALL NEW AND REPLACED LANDSCAPE AREAS CDS SEPARATOR EXHIBIT B - OPERATIONS AND MAINTENANCE 39Page 5 of ® Filterra® Maintenance Steps Contech has created a network of Certified Maintenance Providers (CCMP’s) to provide maintenance on Filterra systems. To find a CCMP in your area please visit www.conteches.com/maintenance 1. Inspection of Filterra and surrounding area 2. Removal of tree grate and erosion control stones 3. Removal of debris, trash and mulch 4. Mulch replacement 5. Clean area around Filterra 6. Complete paperwork and record plant height and width © 2015 Contech Engineered Solutions LLC ENGINEERED SOLUTIONS 39Page 5 of 6 ® Filterra® Maintenance Steps Contech has created a network of Certified Maintenance Providers (CCMP’s) to provide maintenance on Filterra systems. To find a CCMP in your area please visit www.conteches.com/maintenance 1. Inspection of Filterra and surrounding area 2. Removal of tree grate and erosion control stones 3. Removal of debris, trash and mulch 4. Mulch replacement 5. Clean area around Filterra 6. Complete paperwork and record plant height and width © 2015 Contech Engineered Solutions LLC ENGINEERED SOLUTIONS MAINTENANCE INSTRUCTIONS FOR FILTERRA VAULT Filterra Vault Owner’s Manual (Precast Vault Configurations) ® Bioretention Systems ENGINEERED SOLUTIONS This Owner’s Manual applies to all precast Filterra Configurations, including Filterra Bioscape Vault and Filterra HC. 39Page 5 of 7 Filterra Vault Owner’s Manual (Precast Vault Configurations) ® Bioretention Systems ENGINEERED SOLUTIONS This Owner’s Manual applies to all precast Filterra Configurations, including Filterra Bioscape Vault and Filterra HC.This Owner's Manual Applies to all precast Filterra Configurations, including Filterra Bioscape Vault and Filterra HC. 39Page 5 of 8 www.ContechES.com/filterra | 800-338-1122 3 Table of Contents Introduction ................................................................................4 Activation Overview .....................................................................4 Filterra Plant Selection Overview ...................................................6 Warranty Overview ......................................................................6 Routine Maintenance Guidelines...................................................6 Maintenance Visit Procedure .........................................................9 Plant Care ................................................................................11 Appendix 1 – Activation Package ................................................12 Appendix 2 – Filterra Tree Grate Opening Expansion Procedure..... 19 ® Bioretention Systems ENGINEERED SOLUTIONS 39Page 5 of 9 www.ContechES.com/filterra | 800-338-1122 3 Table of Contents Introduction ................................................................................4 Activation Overview .....................................................................4 Filterra Plant Selection Overview ...................................................6 Warranty Overview ......................................................................6 Routine Maintenance Guidelines...................................................6 Maintenance Visit Procedure .........................................................9 Plant Care ................................................................................11 Appendix 1 – Activation Package ................................................12 Appendix 2 – Filterra Tree Grate Opening Expansion Procedure..... 19 ® Bioretention Systems ENGINEERED SOLUTIONS www.ContechES.com/filterra | 800-338-1122 www.ContechES.com/filterra | 800-338-11224 Introduction Thank you for your purchase of the Filterra® Bioretention System. Filterra is a specially engineered stormwater treatment system incorporating high performance biofiltration media to remove pollutants from stormwater runoff. The system’s biota (vegetation and soil microorganisms) then further breakdown and absorb captured pollutants. All components of the system work together to provide a sustainable long-term solution for treating stormwater runoff. The Filterra system has been delivered to you with protection in place to resist intrusion of construction related sediment which can contaminate the biofiltration media and result in inadequate system performance. These protection devices are intended as a best practice and cannot fully prevent contamination. It is the purchaser’s responsibility to provide adequate measures to prevent construction related runoff from entering the Filterra system. Included with your purchase is Activation of the Filterra system by the manufacturer as well as a 1-year warranty from delivery of the system and a final site assessment of unit condition (mulch replacement, debris removal, and pruning of vegetation) scheduled between 6 and 12 months after activation, upon request. Design and Installation Each project presents different scopes for the use of Filterra systems. Information and help may be provided to the design engineer during the planning process. Correct Filterra box sizing (by rainfall region) is essential to predict pollutant removal rates for a given area. The engineer shall submit calculations for approval by the local jurisdiction. The contractor is responsible for the correct installation of Filterra units as shown in approved plans. A comprehensive installation manual is available at www.ContechES.com. Activation Overview Activation of the Filterra system is a procedure completed by the manufacturer to place the system into working condition. This involves the following items: • Removal of construction runoff protection devices. • Planting of the system’s vegetation (provided by the purchaser). • Placement of pretreatment mulch layer using mulch acceptable for use in Filterra systems. Activation MUST be provided by the manufacturer to ensure proper site conditions are met for Activation, proper installation of the vegetation, and use of pretreatment mulch acceptable for use in Filterra systems. More information is available in the Filterra Activation Package. 39Page 5 of 10 of www.ContechES.com/filterra | 800-338-11224 Introduction Thank you for your purchase of the Filterra® Bioretention System. Filterra is a specially engineered stormwater treatment system incorporating high performance biofiltration media to remove pollutants from stormwater runoff. The system’s biota (vegetation and soil microorganisms) then further breakdown and absorb captured pollutants. All components of the system work together to provide a sustainable long-term solution for treating stormwater runoff. The Filterra system has been delivered to you with protection in place to resist intrusion of construction related sediment which can contaminate the biofiltration media and result in inadequate system performance. These protection devices are intended as a best practice and cannot fully prevent contamination. It is the purchaser’s responsibility to provide adequate measures to prevent construction related runoff from entering the Filterra system. Included with your purchase is Activation of the Filterra system by the manufacturer as well as a 1-year warranty from delivery of the system and a final site assessment of unit condition (mulch replacement, debris removal, and pruning of vegetation) scheduled between 6 and 12 months after activation, upon request. Design and Installation Each project presents different scopes for the use of Filterra systems. Information and help may be provided to the design engineer during the planning process. Correct Filterra box sizing (by rainfall region) is essential to predict pollutant removal rates for a given area. The engineer shall submit calculations for approval by the local jurisdiction. The contractor is responsible for the correct installation of Filterra units as shown in approved plans. A comprehensive installation manual is available at www.ContechES.com. Activation Overview Activation of the Filterra system is a procedure completed by the manufacturer to place the system into working condition. This involves the following items: • Removal of construction runoff protection devices. • Planting of the system’s vegetation (provided by the purchaser). • Placement of pretreatment mulch layer using mulch acceptable for use in Filterra systems. Activation MUST be provided by the manufacturer to ensure proper site conditions are met for Activation, proper installation of the vegetation, and use of pretreatment mulch acceptable for use in Filterra systems. More information is available in the Filterra Activation Package. www.ContechES.com/filterra | 800-338-1122 www.ContechES.com/filterra | 800-338-1122 5 Minimum Requirements The minimum requirements for Filterra Activation are as follows: 1. The purchaser must have procured vegetation meeting the requirements outlined in the Filterra Activation Package. 2. The site landscaping must be fully stabilized, i.e. full landscaping installed and some grass cover (not just straw and seed) is required to reduce sediment transport. Construction debris and materials should be removed from surrounding area. 3. Final paving must be completed. Final paving ensures that paving materials will not enter and contaminate the Filterra system during the paving process, and that the plant will receive runoff from the drainage area, assisting with plant survival for the Filterra system. 4. Filterra throat opening should be at least 4” in order to ensure adequate capacity for inflow and debris. The Filterra Activation Package is available on the Contech website (www.ContechES.com/filterra) and ensures that the proper conditions are met for Contech to perform the Activation service. Vegetation meeting Contech’s requirements must be provided at time of Activation. If the site does not meet the conditions required for Activation, or acceptable vegetation is not provided by the purchaser at time of Activation, a charge of $1,500 will be invoiced to the purchaser. 39Page 5 of 11 of www.ContechES.com/filterra | 800-338-1122 5 Minimum Requirements The minimum requirements for Filterra Activation are as follows: 1. The purchaser must have procured vegetation meeting the requirements outlined in the Filterra Activation Package. 2. The site landscaping must be fully stabilized, i.e. full landscaping installed and some grass cover (not just straw and seed) is required to reduce sediment transport. Construction debris and materials should be removed from surrounding area. 3. Final paving must be completed. Final paving ensures that paving materials will not enter and contaminate the Filterra system during the paving process, and that the plant will receive runoff from the drainage area, assisting with plant survival for the Filterra system. 4. Filterra throat opening should be at least 4” in order to ensure adequate capacity for inflow and debris. The Filterra Activation Package is available on the Contech website (www.ContechES.com/filterra) and ensures that the proper conditions are met for Contech to perform the Activation service. Vegetation meeting Contech’s requirements must be provided at time of Activation. If the site does not meet the conditions required for Activation, or acceptable vegetation is not provided by the purchaser at time of Activation, a charge of $1,500 will be invoiced to the purchaser. www.ContechES.com/filterra | 800-338-1122 www.ContechES.com/filterra | 800-338-11226 Filterra Plant Selection Overview A Plant List is available on the Contech website highlighting recommended plants for Filterra systems in your area. Keep in mind that plants are subject to availability due to seasonality and required minimum size for the Filterra system. Plants installed in the Filterra system are container plants (max 15 gallon) from nursery stock and will be immature in height and spread at Activation. It is the responsibility of the owner to provide adequate irrigation when necessary to the plant of the Filterra system. More information is available in the Filterra Activation Package. Warranty Overview Refer to the Contech Engineered Solutions LLC Stormwater Treatment System LIMITED WARRANTY for further information. The following conditions may void the Filterra system’s warranty and waive the manufacturer provided Activation and Final Site Assessment services: • Unauthorized activation or performance of any of the items listed in the activation overview • Any tampering, modifications or damage to the Filterra system or runoff protection devices • Removal of any Filterra system components • Failure to prevent construction related runoff from entering the Filterra system • Failure to properly store and protect any Filterra components (including media and underdrain stone) that may be shipped separately from the vault Final Site Assessment With proper routine maintenance, the biofiltration media within the Filterra system should last as long as traditional bioretention media. A final site assessment is included by the manufacturer, upon request, on all Filterra systems between 6 and 12 months after activation. This includes a final assessment of unit condition, debris removal, mulch replacement, and pruning of vegetation. More information is provided in the Operations and Maintenance Guidelines. Some Filterra systems also contain pretreatment or outlet bays. Depending on site pollutant loading, these bays may require periodic removal of debris, however this is not included in the final site assessment, and would likely not be required within the first year of operation. These services, as well as routine maintenance outside of the included first year, can be provided by certified maintenance providers listed on the Contech website. Training can also be provided to other stormwater maintenance or landscape providers. 39Page 5 of 12 of www.ContechES.com/filterra | 800-338-11226 Filterra Plant Selection Overview A Plant List is available on the Contech website highlighting recommended plants for Filterra systems in your area. Keep in mind that plants are subject to availability due to seasonality and required minimum size for the Filterra system. Plants installed in the Filterra system are container plants (max 15 gallon) from nursery stock and will be immature in height and spread at Activation. It is the responsibility of the owner to provide adequate irrigation when necessary to the plant of the Filterra system. More information is available in the Filterra Activation Package. Warranty Overview Refer to the Contech Engineered Solutions LLC Stormwater Treatment System LIMITED WARRANTY for further information. The following conditions may void the Filterra system’s warranty and waive the manufacturer provided Activation and Final Site Assessment services: • Unauthorized activation or performance of any of the items listed in the activation overview • Any tampering, modifications or damage to the Filterra system or runoff protection devices • Removal of any Filterra system components • Failure to prevent construction related runoff from entering the Filterra system • Failure to properly store and protect any Filterra components (including media and underdrain stone) that may be shipped separately from the vault Final Site Assessment With proper routine maintenance, the biofiltration media within the Filterra system should last as long as traditional bioretention media. A final site assessment is included by the manufacturer, upon request, on all Filterra systems between 6 and 12 months after activation. This includes a final assessment of unit condition, debris removal, mulch replacement, and pruning of vegetation. More information is provided in the Operations and Maintenance Guidelines. Some Filterra systems also contain pretreatment or outlet bays. Depending on site pollutant loading, these bays may require periodic removal of debris, however this is not included in the final site assessment, and would likely not be required within the first year of operation. These services, as well as routine maintenance outside of the included first year, can be provided by certified maintenance providers listed on the Contech website. Training can also be provided to other stormwater maintenance or landscape providers. www.ContechES.com/filterra | 800-338-1122 www.ContechES.com/filterra | 800-338-1122 7 Why Maintain? All stormwater treatment systems require maintenance for effective operation. This necessity is often incorporated in your property’s permitting process as a legally binding BMP maintenance agreement. Other reasons to maintain are: • Avoiding legal challenges from your jurisdiction’s maintenance enforcement program. • Prolonging the expected lifespan of your Filterra media. • Avoiding more costly media replacement. • Helping reduce pollutant loads leaving your property. Simple maintenance of the Filterra is required to continue effective pollutant removal from stormwater runoff before discharge into downstream waters. This procedure will also extend the longevity of the living biofilter system. The unit will recycle and accumulate pollutants within the biomass, but is also subjected to other materials entering the inlet. This may include trash, silt and leaves etc. which will be contained above the mulch layer. Too much silt may inhibit the Filterra’s flow rate, which is the reason for site stabilization before activation. Regular replacement of the mulch stops accumulation of such sediment. When to Maintain? Maintenance visits are scheduled seasonally; the spring visit aims to clean up after winter loads including salts and sands while the fall visit helps the system by removing excessive leaf litter. It has been found that in regions which receive between 30-50 inches of annual rainfall, (2) two visits are generally required; in regions with less rainfall often only (1) one visit per annum is sufficient. Varying land uses can affect maintenance frequency. Contributing drainage areas which are subject to new development wherein the recommended erosion and sediment control measures have not been implemented may require additional maintenance visits. Some sites may be subjected to extreme sediment or trash loads, requiring more frequent maintenance visits. This is the reason for detailed notes of maintenance actions per unit, helping the Supplier and Owner predict future maintenance frequencies, reflecting individual site conditions. Owners must promptly notify the maintenance provider of any damage to the plant(s), which constitute(s) an integral part of the bioretention technology. www.ContechES.com/filterra | 800-338-1122 7 Why Maintain? All stormwater treatment systems require maintenance for effective operation. This necessity is often incorporated in your property’s permitting process as a legally binding BMP maintenance agreement. Other reasons to maintain are: • Avoiding legal challenges from your jurisdiction’s maintenance enforcement program. • Prolonging the expected lifespan of your Filterra media. • Avoiding more costly media replacement. • Helping reduce pollutant loads leaving your property. Simple maintenance of the Filterra is required to continue effective pollutant removal from stormwater runoff before discharge into downstream waters. This procedure will also extend the longevity of the living biofilter system. The unit will recycle and accumulate pollutants within the biomass, but is also subjected to other materials entering the inlet. This may include trash, silt and leaves etc. which will be contained above the mulch layer. Too much silt may inhibit the Filterra’s flow rate, which is the reason for site stabilization before activation. Regular replacement of the mulch stops accumulation of such sediment. When to Maintain? Maintenance visits are scheduled seasonally; the spring visit aims to clean up after winter loads including salts and sands while the fall visit helps the system by removing excessive leaf litter. It has been found that in regions which receive between 30-50 inches of annual rainfall, (2) two visits are generally required; in regions with less rainfall often only (1) one visit per annum is sufficient. Varying land uses can affect maintenance frequency. Contributing drainage areas which are subject to new development wherein the recommended erosion and sediment control measures have not been implemented may require additional maintenance visits. Some sites may be subjected to extreme sediment or trash loads, requiring more frequent maintenance visits. This is the reason for detailed notes of maintenance actions per unit, helping the Supplier and Owner predict future maintenance frequencies, reflecting individual site conditions. Owners must promptly notify the maintenance provider of any damage to the plant(s), which constitute(s) an integral part of the bioretention technology. www.ContechES.com/filterra | 800-338-1122 Page 5 of 13 of 39 www.ContechES.com/filterra | 800-338-11228 Exclusion of Services Clean up due to major contamination such as oils, chemicals, toxic spills, etc. will result in additional costs and are not included as part of the final site assessment. Should a major contamination event occur the Owner must block off the outlet pipe of the Filterra (where the cleaned runoff drains to, such as drop inlet) and block off the throat of the Filterra. The Supplier should be informed immediately. Maintenance Visit Summary Each maintenance visit consists of the following simple tasks (detailed instructions below). 1. Inspection of Filterra and surrounding area 2. Removal of tree grate and erosion control stones 3. Removal of debris, trash and mulch 4. Mulch replacement 5. Plant health evaluation and pruning or replacement as necessary 6. Clean area around Filterra 7. Complete paperwork Maintenance Tools, Safety Equipment and Supplies Ideal tools include: camera, bucket, shovel, broom, pruners, hoe/rake, and tape measure. Appropriate Personal Protective Equipment (PPE) should be used in accordance with local or company procedures. This may include impervious gloves where the type of trash is unknown, high visibility clothing and barricades when working in close proximity to traffic and also safety hats and shoes. A T-Bar or crowbar should be used for moving the tree grates (up to 170 lbs ea.). Most visits require minor trash removal and a full replacement of mulch. See below for actual number of bagged mulch that is required in each media bay size. Mulch should be a double shredded, hardwood variety. Some visits may require additional Filterra engineered soil media available from the Supplier. Box Length Box Width Filter Surface Area (ft²)Volume at 3” (ft³)# of 2 ft³ Mulch Bags 4 4 16 4 2 6 4 24 6 3 8 4 32 8 4 6 6 36 9 5 8 6 48 12 6 10 6 60 15 8 12 6 72 18 9 13 7 91 23 12 Other sizes not listed - 1 bag per 8 ft2 of media. Page 5 of www.ContechES.com/filterra | 800-338-11228 Exclusion of Services Clean up due to major contamination such as oils, chemicals, toxic spills, etc. will result in additional costs and are not included as part of the final site assessment. Should a major contamination event occur the Owner must block off the outlet pipe of the Filterra (where the cleaned runoff drains to, such as drop inlet) and block off the throat of the Filterra. The Supplier should be informed immediately. Maintenance Visit Summary Each maintenance visit consists of the following simple tasks (detailed instructions below). 1. Inspection of Filterra and surrounding area 2. Removal of tree grate and erosion control stones 3. Removal of debris, trash and mulch 4. Mulch replacement 5. Plant health evaluation and pruning or replacement as necessary 6. Clean area around Filterra 7. Complete paperwork Maintenance Tools, Safety Equipment and Supplies Ideal tools include: camera, bucket, shovel, broom, pruners, hoe/rake, and tape measure. Appropriate Personal Protective Equipment (PPE) should be used in accordance with local or company procedures. This may include impervious gloves where the type of trash is unknown, high visibility clothing and barricades when working in close proximity to traffic and also safety hats and shoes. A T-Bar or crowbar should be used for moving the tree grates (up to 170 lbs ea.). Most visits require minor trash removal and a full replacement of mulch. See below for actual number of bagged mulch that is required in each media bay size. Mulch should be a double shredded, hardwood variety. Some visits may require additional Filterra engineered soil media available from the Supplier. Box Length Box Width Filter Surface Area (ft²)Volume at 3” (ft³)# of 2 ft³ Mulch Bags 4 4 16 4 2 6 4 24 6 3 8 4 32 8 4 6 6 36 9 5 8 6 48 12 6 10 6 60 15 8 12 6 72 18 9 13 7 91 23 12 Other sizes not listed - 1 bag per 8 ft2 of media. 14 of 39 www.ContechES.com/filterra | 800-338-1122 www.ContechES.com/filterra | 800-338-1122 9 1. Inspection of Filterra and surrounding area • Record individual unit before maintenance with photograph (numbered). Record on Maintenance Report (see example in this document) the following: 2. Removal of tree grate and erosion control stones • Remove cast iron grates for access into Filterra box. • Dig out silt (if any) and mulch and remove trash & foreign items. 3. Removal of debris, trash and mulch • After removal of mulch and debris, measure distance from the top of the Filterra engineered media soil to the top of the top slab. Compare the measured distance to the distance shown on the approved Contract Drawings for the system. Add Filterra media (not top soil or other) to bring media up as needed to distance indicated on drawings. Record on Maintenance Report the following: Standing Water yes | no Damage to Box Structure yes | no Damage to Grate yes | no Is Bypass Clear yes | no If yes answered to any of these observations, record with close-up photograph (numbered). Record on Maintenance Report the following: Silt/Clay yes | no Cups/ Bags yes | no Leaves yes | no Buckets Removed ________ Record on Maintenance Report the following: Distance to Top of Top Slab (inches) ________ Inches of Media Added ________ Maintenance Visit Procedure Keep sufficient documentation of maintenance actions to predict location specific maintenance frequencies and needs. An example Maintenance Report is included in this manual. Page 5 of 15 of 39 www.ContechES.com/filterra | 800-338-1122 9 1. Inspection of Filterra and surrounding area • Record individual unit before maintenance with photograph (numbered). Record on Maintenance Report (see example in this document) the following: 2. Removal of tree grate and erosion control stones • Remove cast iron grates for access into Filterra box. • Dig out silt (if any) and mulch and remove trash & foreign items. 3. Removal of debris, trash and mulch • After removal of mulch and debris, measure distance from the top of the Filterra engineered media soil to the top of the top slab. Compare the measured distance to the distance shown on the approved Contract Drawings for the system. Add Filterra media (not top soil or other) to bring media up as needed to distance indicated on drawings. Record on Maintenance Report the following: Standing Water yes | no Damage to Box Structure yes | no Damage to Grate yes | no Is Bypass Clear yes | no If yes answered to any of these observations, record with close-up photograph (numbered). Record on Maintenance Report the following: Silt/Clay yes | no Cups/ Bags yes | no Leaves yes | no Buckets Removed ________ Record on Maintenance Report the following: Distance to Top of Top Slab (inches) ________ Inches of Media Added ________ Maintenance Visit Procedure Keep sufficient documentation of maintenance actions to predict location specific maintenance frequencies and needs. An example Maintenance Report is included in this manual. www.ContechES.com/filterra | 800-338-1122 www.ContechES.com/filterra | 800-338-112210 4. Mulch replacement • Add double shredded mulch evenly across the entire unit to a depth of 3”. • Refer to Filterra Mulch Specifications for information on acceptable sources. • Ensure correct repositioning of erosion control stones by the Filterra inlet to allow for entry of trash during a storm event. • Replace Filterra grates correctly using appropriate lifting or moving tools, taking care not to damage the plant. 5. Plant health evaluation and pruning or replacement as necessary • Examine the plant’s health and replace if necessary. • Prune as necessary to encourage growth in the correct directions 6. Clean area around Filterra • Clean area around unit and remove all refuse to be disposed of appropriately. 7. Complete paperwork • Deliver Maintenance Report. • Some jurisdictions may require submission of maintenance reports in accordance with approvals. It is the responsibility of the Owner to comply with local regulations. Record on Maintenance Report the following: Height above Grate _____________________(ft) Width at Widest Point _____________________(ft) Health healthy | unhealthy Damage to Plant yes | no Plant Replaced yes | no Page 5 of 16 of 39 www.ContechES.com/filterra | 800-338-112210 4. Mulch replacement • Add double shredded mulch evenly across the entire unit to a depth of 3”. • Refer to Filterra Mulch Specifications for information on acceptable sources. • Ensure correct repositioning of erosion control stones by the Filterra inlet to allow for entry of trash during a storm event. • Replace Filterra grates correctly using appropriate lifting or moving tools, taking care not to damage the plant. 5. Plant health evaluation and pruning or replacement as necessary • Examine the plant’s health and replace if necessary. • Prune as necessary to encourage growth in the correct directions 6. Clean area around Filterra • Clean area around unit and remove all refuse to be disposed of appropriately. 7. Complete paperwork • Deliver Maintenance Report. • Some jurisdictions may require submission of maintenance reports in accordance with approvals. It is the responsibility of the Owner to comply with local regulations. Record on Maintenance Report the following: Height above Grate _____________________(ft) Width at Widest Point _____________________(ft) Health healthy | unhealthy Damage to Plant yes | no Plant Replaced yes | no www.ContechES.com/filterra | 800-338-1122 www.ContechES.com/filterra | 800-338-1122 11 Plant Care for Filterra® Systems After Activation, the Contractor is responsible for proper care of the vegetation until the site is handed over to the Owner. After that, it is the Site Owner’s responsibility to care for the vegetation. Contech recommends the following care for the plants: 1. To prevent transplant shock (especially if planting takes place in the hot season), it may be necessary to prune some of the foliage to compensate for reduced root uptake capacity. This is accomplished by pruning away some of the smaller secondary branches or a main scaffold branch if there are too many. Too much foliage relative to the root ball can dehydrate and damage the plant. 2. Plant staking may be required. 3. With all trees/shrubs, remove dead, diseased, crossed/ rubbing, sharply crotched branches or branches growing excessively long or in wrong direction compared to majority of branches. 4. Contech recommends irrigation of the Filterra® Vegetation. The following guidance will help to ensure the vegetation is properly irrigated. Irrigation Recommendations: • Each Filterra® system must receive adequate irrigation to ensure survival of the living system during periods of drier weather. • Irrigation sources include rainfall runoff from downspouts and/or gutter flow, applied water through the tree grate or in some cases from an irrigation system with emitters installed during construction. • At Activation: Apply about one (cool climates) to two (warm climates) gallons of water per inch of trunk diameter over the root ball. • During Establishment: In common with all plants, each Filterra® plant will require more frequent watering during the establishment period. One inch of applied water per week for the first three months is recommended for cooler climates (2 to 3 inches for warmer climates). If the system is receiving rainfall runoff from the drainage area, then irrigation may not be needed. Inspection of the soil moisture content can be evaluated by gently brushing aside the mulch layer and feeling the soil. Be sure to replace the mulch when the assessment is complete. Irrigate as needed**. • Established Plants: Established plants have fully developed root systems and can access the entire water column in the media. Therefore irrigation is less frequent but requires more applied water when performed. For a mature system assume 3.5 inches of available water within the media matrix. Irrigation demand can be estimated as 1” of irrigation demand per week. Therefore if dry periods exceed 3 weeks, irrigation may be required. ** Five gallons per square yard approximates 1 inch of water. Therefore for a 6’ x 6 foot Filterra® approximately 20-60 gallons of applied water is needed. To ensure even distribution of water it needs to be evenly sprinkled over the entire surface of the filter bed, with special attention to make sure the root ball is completely wetted. NOTE: if needed, measure the time it takes to fill a five gallon bucket to estimate the applied water flow rate. Then calculate the time needed to irrigate the Filterra®, For example is the flow rate of the sprinkler is 5 gallons/minute then it would take 12 minutes to irrigate a 6’x6’ filter. Plant Replacement: In some cases, plants will require replacement. Please follow the procedures below to ensure a properly functioning Filterra® system. 1. Remove the existing plant, and leave as much of the Filterra® media in place as possible. 2. Select a replacement per the Filterra® Activation Package. 3. Prior to removing the plant from the container, ensure the soil moisture is sufficient to maintain the integrity of the root ball. If needed, pre-wet the container plant. 4. Cut away any roots which are growing out of the container drain holes. 5. Plant(s) should be carefully removed from the pot by gently pounding on the sides of the container with the fist to loosen root ball. Then carefully slide out. Do not lift plant(s) by trunk as this can break roots and cause soil to fall off. Extract the root ball in a horizontal position and support it to prevent it from breaking apart. Alternatively, the pot can be cut away to minimize root ball disturbance. 6. Excavate a hole with a diameter 4” greater than the root ball, gently place the plant(s). 7. Plant the tree/shrub/grass with the top of the root ball 1” above surrounding media to allow for settling. 8. All plants should have the main stem centered in the tree grate (where applicable) upon completion of installation. 9. Reinstall or add mulch to a depth of 3” per Contech’s mulch specifications for Filterra® systems. Page 5 of 17 of 39 www.ContechES.com/filterra | 800-338-1122 11 Plant Care for Filterra® Systems After Activation, the Contractor is responsible for proper care of the vegetation until the site is handed over to the Owner. After that, it is the Site Owner’s responsibility to care for the vegetation. Contech recommends the following care for the plants: 1. To prevent transplant shock (especially if planting takes place in the hot season), it may be necessary to prune some of the foliage to compensate for reduced root uptake capacity. This is accomplished by pruning away some of the smaller secondary branches or a main scaffold branch if there are too many. Too much foliage relative to the root ball can dehydrate and damage the plant. 2. Plant staking may be required. 3. With all trees/shrubs, remove dead, diseased, crossed/ rubbing, sharply crotched branches or branches growing excessively long or in wrong direction compared to majority of branches. 4. Contech recommends irrigation of the Filterra® Vegetation. The following guidance will help to ensure the vegetation is properly irrigated. Irrigation Recommendations: • Each Filterra® system must receive adequate irrigation to ensure survival of the living system during periods of drier weather. • Irrigation sources include rainfall runoff from downspouts and/or gutter flow, applied water through the tree grate or in some cases from an irrigation system with emitters installed during construction. • At Activation: Apply about one (cool climates) to two (warm climates) gallons of water per inch of trunk diameter over the root ball. • During Establishment: In common with all plants, each Filterra® plant will require more frequent watering during the establishment period. One inch of applied water per week for the first three months is recommended for cooler climates (2 to 3 inches for warmer climates). If the system is receiving rainfall runoff from the drainage area, then irrigation may not be needed. Inspection of the soil moisture content can be evaluated by gently brushing aside the mulch layer and feeling the soil. Be sure to replace the mulch when the assessment is complete. Irrigate as needed**. • Established Plants: Established plants have fully developed root systems and can access the entire water column in the media. Therefore irrigation is less frequent but requires more applied water when performed. For a mature system assume 3.5 inches of available water within the media matrix. Irrigation demand can be estimated as 1” of irrigation demand per week. Therefore if dry periods exceed 3 weeks, irrigation may be required. ** Five gallons per square yard approximates 1 inch of water. Therefore for a 6’ x 6 foot Filterra® approximately 20-60 gallons of applied water is needed. To ensure even distribution of water it needs to be evenly sprinkled over the entire surface of the filter bed, with special attention to make sure the root ball is completely wetted. NOTE: if needed, measure the time it takes to fill a five gallon bucket to estimate the applied water flow rate. Then calculate the time needed to irrigate the Filterra®, For example is the flow rate of the sprinkler is 5 gallons/minute then it would take 12 minutes to irrigate a 6’x6’ filter. Plant Replacement: In some cases, plants will require replacement. Please follow the procedures below to ensure a properly functioning Filterra® system. 1. Remove the existing plant, and leave as much of the Filterra® media in place as possible. 2. Select a replacement per the Filterra® Activation Package. 3. Prior to removing the plant from the container, ensure the soil moisture is sufficient to maintain the integrity of the root ball. If needed, pre-wet the container plant. 4. Cut away any roots which are growing out of the container drain holes. 5. Plant(s) should be carefully removed from the pot by gently pounding on the sides of the container with the fist to loosen root ball. Then carefully slide out. Do not lift plant(s) by trunk as this can break roots and cause soil to fall off. Extract the root ball in a horizontal position and support it to prevent it from breaking apart. Alternatively, the pot can be cut away to minimize root ball disturbance. 6. Excavate a hole with a diameter 4” greater than the root ball, gently place the plant(s). 7. Plant the tree/shrub/grass with the top of the root ball 1” above surrounding media to allow for settling. 8. All plants should have the main stem centered in the tree grate (where applicable) upon completion of installation. 9. Reinstall or add mulch to a depth of 3” per Contech’s mulch specifications for Filterra® systems. www.ContechES.com/filterra | 800-338-1122 www.ContechES.com/filterra | 800-338-112212 Maintenance Checklist Filterra Inspection & Maintenance Log Filterra System Size/Model: _____________________________Location: ____________________________________________ Drainage System Failure Problem Conditions to Check Condition that Should Exist Actions Inlet Excessive sediment or trash accumulation. Accumulated sediments or trash impair free flow of water into Filterra. Inlet should be free of obstructions allowing free distributed flow of water into Filterra. Sediments and/or trash should be removed. Mulch Cover Trash and floatable debris accumulation.Excessive trash and/or debris accumulation.Minimal trash or other debris on mulch cover. Trash and debris should be removed and mulch cover raked level. Ensure bark nugget mulch is not used. Mulch Cover “Ponding” of water on mulch cover. “Ponding” in unit could be indicative of clogging due to excessive fine sediment accumulation or spill of petroleum oils. Stormwater should drain freely and evenly through mulch cover. Recommend contact manufacturer and replace mulch as a minimum. Vegetation Plants not growing or in poor condition. Soil/mulch too wet, evidence of spill. Incorrect plant selection. Pest infestation. Vandalism to plants. Plants should be healthy and pest free.Contact manufacturer for advice. Vegetation Plant growth excessive. Plants should be appropriate to the species and location of Filterra. Trim/prune plants in accordance with typical landscaping and safety needs. Structure Structure has visible cracks. Cracks wider than 1/2 inch or evidence of soil particles entering the structure through the cracks. Vault should be repaired. Maintenance is ideally to be performed twice annually. Date Mulch & Debris Removed Depth of Mulch Added Mulch Brand Height of Vegetation Above Grate Vegetation Species Issues with System Comments 1/1/17 5 – 5 gal Buckets 3”Lowe’s Premium Brown Mulch 4’Galaxy Magnolia - Standing water in downstream structure - Removed blockage in downstream structure Page 5 of 18 of 39 www.ContechES.com/filterra | 800-338-112212 Maintenance Checklist Filterra Inspection & Maintenance Log Filterra System Size/Model: _____________________________Location: ____________________________________________ Drainage System Failure Problem Conditions to Check Condition that Should Exist Actions Inlet Excessive sediment or trash accumulation. Accumulated sediments or trash impair free flow of water into Filterra. Inlet should be free of obstructions allowing free distributed flow of water into Filterra. Sediments and/or trash should be removed. Mulch Cover Trash and floatable debris accumulation.Excessive trash and/or debris accumulation.Minimal trash or other debris on mulch cover. Trash and debris should be removed and mulch cover raked level. Ensure bark nugget mulch is not used. Mulch Cover “Ponding” of water on mulch cover. “Ponding” in unit could be indicative of clogging due to excessive fine sediment accumulation or spill of petroleum oils. Stormwater should drain freely and evenly through mulch cover. Recommend contact manufacturer and replace mulch as a minimum. Vegetation Plants not growing or in poor condition. Soil/mulch too wet, evidence of spill. Incorrect plant selection. Pest infestation. Vandalism to plants. Plants should be healthy and pest free.Contact manufacturer for advice. Vegetation Plant growth excessive. Plants should be appropriate to the species and location of Filterra. Trim/prune plants in accordance with typical landscaping and safety needs. Structure Structure has visible cracks. Cracks wider than 1/2 inch or evidence of soil particles entering the structure through the cracks. Vault should be repaired. Maintenance is ideally to be performed twice annually. Date Mulch & Debris Removed Depth of Mulch Added Mulch Brand Height of Vegetation Above Grate Vegetation Species Issues with System Comments 1/1/17 5 – 5 gal Buckets 3”Lowe’s Premium Brown Mulch 4’Galaxy Magnolia - Standing water in downstream structure - Removed blockage in downstream structure www.ContechES.com/filterra | 800-338-1122 please enlarge font to 8 point size or larger as required by state law www.ContechES.com/filterra | 800-338-1122 13 Filterra Activation Package | Page 1 * UNPREPARED SITE FEE NOTE: A charge of $1500.00 will be invoiced for each activation visit requested by customer where Contech determines that the site does not meet the conditions required for Activation AND/OR acceptable plants are not provided by the contractor. ONLY Contech authorized representatives can perform Activation of Filterra systems; unauthorized activations will void the system warranty and waive manufacturer supplied activation and final inspection. ® The Filterra system will be (or has been) delivered to you with protection in place to resist intrusion of construction related sediment which can contaminate the biofiltration media and result in inadequate system performance. These protection devices are intended as a best practice and cannot fully prevent contamination. It is the purchaser’s responsibility to provide adequate measures to prevent construction related runoff from entering the Filterra system. Included with your purchase is Activation of the Filterra system by the manufacturer as well as a 1-year warranty from delivery of the system and a Final Site Assessment (assessment of unit condition, mulch replacement, debris removal, and pruning of vegetation) scheduled between 6 months and 1 year after Activation, upon request. Activation of the Filterra system is a procedure completed by the manufacturer to place the system into working condition. This involves the following items: • Removal of construction runoff protection devices • Planting of the system’s vegetation (provided by the purchaser) • Placement of pretreatment mulch layer using mulch acceptable for use in Filterra systems. Activation MUST be provided by the manufacturer to ensure proper site conditions are met for Activation, proper installation of the vegetation, and use of pretreatment mulch acceptable for use in Filterra systems. The purchaser should request Activation from Contech after the site is stabilized, but prior to turning over the site to the owner. Please allow 1-2 weeks to schedule Activation. The purchaser must ensure that the site is acceptable for Filterra Activation. A checklist (included as page 3 of this document must be completed and submitted to the Contech Activation Coordinator. The minimum 4 requirements for Filterra Activation are as follows: 1. The purchaser must have sourced vegetation meeting the requirements outlined in “Plant Selection for Filterra Systems” starting on page 4 of this document. FILTERRA® VAULT ACTIVATION PACKAGE ENGINEERED SOLUTIONS Appendix 1 – Filterra® Vault Activation Package Page 5 of 19 of 39 www.ContechES.com/filterra | 800-338-1122 13 Filterra Activation Package | Page 1 * UNPREPARED SITE FEE NOTE: A charge of $1500.00 will be invoiced for each activation visit requested by customer where Contech determines that the site does not meet the conditions required for Activation AND/OR acceptable plants are not provided by the contractor. ONLY Contech authorized representatives can perform Activation of Filterra systems; unauthorized activations will void the system warranty and waive manufacturer supplied activation and final inspection. ® The Filterra system will be (or has been) delivered to you with protection in place to resist intrusion of construction related sediment which can contaminate the biofiltration media and result in inadequate system performance. These protection devices are intended as a best practice and cannot fully prevent contamination. It is the purchaser’s responsibility to provide adequate measures to prevent construction related runoff from entering the Filterra system. Included with your purchase is Activation of the Filterra system by the manufacturer as well as a 1-year warranty from delivery of the system and a Final Site Assessment (assessment of unit condition, mulch replacement, debris removal, and pruning of vegetation) scheduled between 6 months and 1 year after Activation, upon request. Activation of the Filterra system is a procedure completed by the manufacturer to place the system into working condition. This involves the following items: • Removal of construction runoff protection devices • Planting of the system’s vegetation (provided by the purchaser) • Placement of pretreatment mulch layer using mulch acceptable for use in Filterra systems. Activation MUST be provided by the manufacturer to ensure proper site conditions are met for Activation, proper installation of the vegetation, and use of pretreatment mulch acceptable for use in Filterra systems. The purchaser should request Activation from Contech after the site is stabilized, but prior to turning over the site to the owner. Please allow 1-2 weeks to schedule Activation. The purchaser must ensure that the site is acceptable for Filterra Activation. A checklist (included as page 3 of this document must be completed and submitted to the Contech Activation Coordinator. The minimum 4 requirements for Filterra Activation are as follows: 1. The purchaser must have sourced vegetation meeting the requirements outlined in “Plant Selection for Filterra Systems” starting on page 4 of this document. FILTERRA® VAULT ACTIVATION PACKAGE ENGINEERED SOLUTIONS Appendix 1 – Filterra® Vault Activation Package www.ContechES.com/filterra | 800-338-1122 please enlarge font to 8 point size or larger as required by state law www.ContechES.com/filterra | 800-338-112214 Filterra Activation Package | Page 2 * UNPREPARED SITE FEE NOTE: A charge of $1500.00 will be invoiced for each activation visit requested by customer where Contech determines that the site does not meet the conditions required for Activation AND/OR acceptable plants are not provided by the contractor. ONLY Contech authorized representatives can perform Activation of Filterra systems; unauthorized activations will void the system warranty and waive manufacturer supplied activation and final inspection. ® 2. The site landscaping must be fully stabilized, i.e. full landscaping installed and some grass cover (not just straw and seed) is required to reduce sediment transport. Construction debris and materials should be removed from surrounding area. 3. Final paving must be completed. Final paving ensures that paving materials will not enter and contaminate the Filterra system during the paving process, and that the plant will receive runoff from the drainage area, assisting with plant survival for the Filterra system. 4. Where curb inlets are included as part of the Filterra system, Filterra throat opening should be at least 4” clear in order to ensure adequate capacity for inflow and debris. Page 5 of 20 of 39 www.ContechES.com/filterra | 800-338-112214 Filterra Activation Package | Page 2 * UNPREPARED SITE FEE NOTE: A charge of $1500.00 will be invoiced for each activation visit requested by customer where Contech determines that the site does not meet the conditions required for Activation AND/OR acceptable plants are not provided by the contractor. ONLY Contech authorized representatives can perform Activation of Filterra systems; unauthorized activations will void the system warranty and waive manufacturer supplied activation and final inspection. ® 2. The site landscaping must be fully stabilized, i.e. full landscaping installed and some grass cover (not just straw and seed) is required to reduce sediment transport. Construction debris and materials should be removed from surrounding area. 3. Final paving must be completed. Final paving ensures that paving materials will not enter and contaminate the Filterra system during the paving process, and that the plant will receive runoff from the drainage area, assisting with plant survival for the Filterra system. 4. Where curb inlets are included as part of the Filterra system, Filterra throat opening should be at least 4” clear in order to ensure adequate capacity for inflow and debris. www.ContechES.com/filterra | 800-338-1122 * UNPREPARED SITE FEE NOTE: A charge of $1500.00 will be invoiced for each activation visit requested by customer where Contech determines that the site does not meet the conditions required for Activation AND/OR acceptable plants are not provided by the contractor. ONLY Contech authorized representatives can perform Activation of Filterra systems; unauthorized activations will void the system warranty and waive manufacturer supplied activation and final inspection. Filterra Activation Package | Page 2 ® please enlarge font to 8 point size or larger as required by state law www.ContechES.com/filterra | 800-338-1122 15 Filterra Activation Package | Page 3 * UNPREPARED SITE FEE NOTE: A charge of $1500.00 will be invoiced for each activation visit requested by customer where Contech determines that the site does not meet the conditions required for Activation AND/OR acceptable plants are not provided by the contractor. ONLY Contech authorized representatives can perform Activation of Filterra systems; unauthorized activations will void the system warranty and waive manufacturer supplied activation and final inspection. ® Filterra® Vault Activation Checklist Project Name: ________________________________________Company: ______________________________________________ Site Contact Name: _______________________________________Site Contact Phone/Email: ____________________________ Site Owner/End User Name: _________________________Site Owner/End User Phone/Email: ____________________________ Preferred Activation Date: ___________________________________(provide 2 weeks minimum from date this form is submitted) Site Designation Top Opening Type Final Pavement Complete Landscaping Complete / Grass Emerging Construction materials / Piles / Debris Removed Throat Opening Measures 4” Min. Height (where applicable) Vegetation Sourced by Contractor Tree Grate Full Grate (No tree opening) Bioscape Vault (Open Planter) Verified Verified Verified Verified Species on FT Plant List Container Grown (15 gal. max) 4’ Tall Min. (Tree grate units only) ____ Qty provided Tree Grate Full Grate (No tree opening) Bioscape Vault (Open Planter) Verified Verified Verified Verified Species on FT Plant List Container Grown (15 gal. max) 4’ Tall Min. (Tree grate units only) ____ Qty provided Tree Grate Full Grate (No tree opening) Bioscape Vault (Open Planter) Verified Verified Verified Verified Species on FT Plant List Container Grown (15 gal. max) 4’ Tall Min. (Tree grate units only) ____ Qty provided Tree Grate Full Grate (No tree opening) Bioscape Vault (Open Planter) Verified Verified Verified Verified Species on FT Plant List Container Grown (15 gal. max) 4’ Tall Min. (Tree grate units only) ____ Qty provided NOTE: A charge of $1500.00 will be invoiced for each activation visit requested by customer where Contech determines that the site does not meet the conditions required for activation AND/OR acceptable plants are not provided by the contractor. ONLY Contech authorized representatives can perform activation of Filterra systems; unauthorized activations will void the system warranty and waive manufacturer supplied activation and final inspection. Attach additional sheets as necessary. Signature Date ENGINEERED SOLUTIONS Page 5 of 21 of 39 Filterra Activation Package | Page 3 * UNPREPARED SITE FEE NOTE: A charge of $1500.00 will be invoiced for each activation visit requested by customer where Contech determines that the site does not meet the conditions required for Activation AND/OR acceptable plants are not provided by the contractor. ONLY Contech authorized representatives can perform Activation of Filterra systems; unauthorized activations will void the system warranty and waive manufacturer supplied activation and final inspection. ® Filterra® Vault Activation Checklist Project Name: ________________________________________Company: ______________________________________________ Site Contact Name: _______________________________________Site Contact Phone/Email: ____________________________ Site Owner/End User Name: _________________________Site Owner/End User Phone/Email: ____________________________ Preferred Activation Date: ___________________________________(provide 2 weeks minimum from date this form is submitted) Site Designation Top Opening Type Final Pavement Complete Landscaping Complete / Grass Emerging Construction materials / Piles / Debris Removed Throat Opening Measures 4” Min. Height (where applicable) Vegetation Sourced by Contractor Tree Grate Full Grate (No tree opening) Bioscape Vault (Open Planter) Verified Verified Verified Verified Species on FT Plant List Container Grown (15 gal. max) 4’ Tall Min. (Tree grate units only) ____ Qty provided Tree Grate Full Grate (No tree opening) Bioscape Vault (Open Planter) Verified Verified Verified Verified Species on FT Plant List Container Grown (15 gal. max) 4’ Tall Min. (Tree grate units only) ____ Qty provided Tree Grate Full Grate (No tree opening) Bioscape Vault (Open Planter) Verified Verified Verified Verified Species on FT Plant List Container Grown (15 gal. max) 4’ Tall Min. (Tree grate units only) ____ Qty provided Tree Grate Full Grate (No tree opening) Bioscape Vault (Open Planter) Verified Verified Verified Verified Species on FT Plant List Container Grown (15 gal. max) 4’ Tall Min. (Tree grate units only) ____ Qty provided NOTE: A charge of $1500.00 will be invoiced for each activation visit requested by customer where Contech determines that the site does not meet the conditions required for activation AND/OR acceptable plants are not provided by the contractor. ONLY Contech authorized representatives can perform activation of Filterra systems; unauthorized activations will void the system warranty and waive manufacturer supplied activation and final inspection. Attach additional sheets as necessary. Signature Date ENGINEERED SOLUTIONS * UNPREPARED SITE FEE NOTE: A charge of $1500.00 will be invoiced for each activation visit requested by customer where Contech determines that the site does not meet the conditions required for Activation AND/OR acceptable plants are not provided by the contractor. ONLY Contech authorized representatives can perform Activation of Filterra systems; unauthorized activations will void the system warranty and waive manufacturer supplied activation and final inspection. www.ContechES.com/filterra | 800-338-1122 vations will void the system war Filterra Activation Package | Page 3 ® please enlarge font to 8 point size or larger as required by state law www.ContechES.com/filterra | 800-338-112216 Filterra Activation Package | Page 4 * UNPREPARED SITE FEE NOTE: A charge of $1500.00 will be invoiced for each activation visit requested by customer where Contech determines that the site does not meet the conditions required for Activation AND/OR acceptable plants are not provided by the contractor. ONLY Contech authorized representatives can perform Activation of Filterra systems; unauthorized activations will void the system warranty and waive manufacturer supplied activation and final inspection. ® Planting Selection for Filterra® Vault Systems All Filterra systems require vegetation for proper long-term performance. As indicated in the Activation Package, the Contractor is responsible for sourcing the proper vegetation prior to Activation. Contech or a Contech representative will install the vegetation during the Activation process. Contractors should identify the Top Opening style for each Filterra requiring Activation on the Activation Checklist. Contech offers three types, which are detailed on page 5 of this document: • Vault with Tree Grate • Vault with Full Grate • Bioscape / Open Planter Contractors must ensure the vegetation meets the following 4 requirements: 1. Select plant(s) as specified in the engineering plans and specifications AND that are listed on Contech’s Configuration Specific Plant Lists**. 2. All plants MUST be container-grown in nursery containers no larger than 15 gallons. Crated and/or Ball/Burlap plants are NOT permitted. 3. For Vaults with Tree Grates, plant height must be 4’ Minimum, from soil surface to top of plant. 4. Provide plant quantities per the following guidance: • Vault with Tree Grate – 1 per Tree Grate • Vault with Full Grate – 4-5 Small or Extra Small Grasses per Full Grate • Bioscape – Quantities should be selected based on plant palette options found starting on page 6 of this document. If Contech or Contech’s representative shows up for Activation and any of the 4 requirements above are not met, Activation cannot be performed and the Contractor will be billed a $1,500 Unprepared Site fee*. Some additional vegetation recommendations for the best possible Activation and Installation are as follows: • Select plant(s) with full root development but not to the point where root bound. • For Filterra systems with a Tree Grate, select plants with taller trunks. Lower branches can be pruned away provided there are sufficient branches above the grate for tree or shrub development. • For Filterra systems with a Tree Grate, plant(s) should have a single trunk at installation. • Plant species shall not have a mature height greater than 30 feet. ** In some cases, Contech may consider alternate plant species as approved by the Product Manager. Please list the plant name in the space below and submit this sheet to your Contech Activation Coordinator. If the plant species is approved, either the Product Manager or the Activation Coordinator will sign the form and return to you for inclusion with your Activation Checklist. Requested Plant Species: ___________________________________________Approved: _______________________________ Date: ____________________________________ Page 5 of 22 of 39 www.ContechES.com/filterra | 800-338-1122 Filterra Activation Package | Page 4 * UNPREPARED SITE FEE NOTE: A charge of $1500.00 will be invoiced for each activation visit requested by customer where Contech determines that the site does not meet the conditions required for Activation AND/OR acceptable plants are not provided by the contractor. ONLY Contech authorized representatives can perform Activation of Filterra systems; unauthorized activations will void the system warranty and waive manufacturer supplied activation and final inspection. ® Planting Selection for Filterra® Vault Systems All Filterra systems require vegetation for proper long-term performance. As indicated in the Activation Package, the Contractor is responsible for sourcing the proper vegetation prior to Activation. Contech or a Contech representative will install the vegetation during the Activation process. Contractors should identify the Top Opening style for each Filterra requiring Activation on the Activation Checklist. Contech offers three types, which are detailed on page 5 of this document: • Vault with Tree Grate • Vault with Full Grate • Bioscape / Open Planter Contractors must ensure the vegetation meets the following 4 requirements: 1. Select plant(s) as specified in the engineering plans and specifications AND that are listed on Contech’s Configuration Specific Plant Lists**. 2. All plants MUST be container-grown in nursery containers no larger than 15 gallons. Crated and/or Ball/Burlap plants are NOT permitted. 3. For Vaults with Tree Grates, plant height must be 4’ Minimum, from soil surface to top of plant. 4. Provide plant quantities per the following guidance: • Vault with Tree Grate – 1 per Tree Grate • Vault with Full Grate – 4-5 Small or Extra Small Grasses per Full Grate • Bioscape – Quantities should be selected based on plant palette options found starting on page 6 of this document. If Contech or Contech’s representative shows up for Activation and any of the 4 requirements above are not met, Activation cannot be performed and the Contractor will be billed a $1,500 Unprepared Site fee*. Some additional vegetation recommendations for the best possible Activation and Installation are as follows: • Select plant(s) with full root development but not to the point where root bound. • For Filterra systems with a Tree Grate, select plants with taller trunks. Lower branches can be pruned away provided there are sufficient branches above the grate for tree or shrub development. • For Filterra systems with a Tree Grate, plant(s) should have a single trunk at installation. • Plant species shall not have a mature height greater than 30 feet. ** In some cases, Contech may consider alternate plant species as approved by the Product Manager. Please list the plant name in the space below and submit this sheet to your Contech Activation Coordinator. If the plant species is approved, either the Product Manager or the Activation Coordinator will sign the form and return to you for inclusion with your Activation Checklist. Requested Plant Species: ___________________________________________Approved: _______________________________ Date: ____________________________________ * UNPREPARED SITE FEE NOTE: A charge of $1500.00 will be invoiced for each activation visit requested by customer where Contech determines that the site does not meet the conditions required for Activation AND/OR acceptable plants are not provided by the contractor. ONLY Contech authorized representatives can perform Activation of Filterra systems; unauthorized activations will void the system warranty and waive manufacturer supplied activation and final inspection. ________________________ Filterra Activation Package | Page 4 ® please enlarge font to 8 point size or larger as required by state law www.ContechES.com/filterra | 800-338-1122 17 Filterra Activation Package | Page 5 * UNPREPARED SITE FEE NOTE: A charge of $1500.00 will be invoiced for each activation visit requested by customer where Contech determines that the site does not meet the conditions required for Activation AND/OR acceptable plants are not provided by the contractor. ONLY Contech authorized representatives can perform Activation of Filterra systems; unauthorized activations will void the system warranty and waive manufacturer supplied activation and final inspection. ® Figure 1a. Filterra with Tree Grate Drawing Figure 2a. Filterra with Full Grate Drawing Figure 3a. Filterra Bioscape Vault Drawing Figure 1b. Filterra with Tree Grate Photo (not yet planted) Figure 2b. Filterra with Full Grate Photo Figure 3b. Filterra Bioscape Vault Photo Filterra® Top Opening Examples Filterra® Vault with Tree Grate Filterra® Vault with Full Grate Filterra® Bioscape Vault Page 5 of 23 of 39 www.ContechES.com/filterra | 800-338-1122 Filterra Activation Package | Page 5 * UNPREPARED SITE FEE NOTE: A charge of $1500.00 will be invoiced for each activation visit requested by customer where Contech determines that the site does not meet the conditions required for Activation AND/OR acceptable plants are not provided by the contractor. ONLY Contech authorized representatives can perform Activation of Filterra systems; unauthorized activations will void the system warranty and waive manufacturer supplied activation and final inspection. ® Figure 1a. Filterra with Tree Grate Drawing Figure 2a. Filterra with Full Grate Drawing Figure 3a. Filterra Bioscape Vault Drawing Figure 1b. Filterra with Tree Grate Photo (not yet planted) Figure 2b. Filterra with Full Grate Photo Figure 3b. Filterra Bioscape Vault Photo Filterra® Top Opening Examples Filterra® Vault with Tree Grate Filterra® Vault with Full Grate Filterra® Bioscape Vault * UNPREPARED SITE FEE NOTE: A charge of $1500.00 will be invoiced for each activation visit requested by customer where Contech determines that the site does not meet the conditions required for Activation AND/OR acceptable plants are not provided by the contractor. ONLY Contech authorized representatives can perform Activation of Filterra systems; unauthorized activations will void the system warranty and waive manufacturer supplied activation and final inspection. Filterra Activation Package | Page 5 ® please enlarge font to 8 point size or larger as required by state law. please also ensure text is clear - some is fuzzy on this page www.ContechES.com/filterra | 800-338-112218 Filterra Activation Package | Page 6 * UNPREPARED SITE FEE NOTE: A charge of $1500.00 will be invoiced for each activation visit requested by customer where Contech determines that the site does not meet the conditions required for Activation AND/OR acceptable plants are not provided by the contractor. ONLY Contech authorized representatives can perform Activation of Filterra systems; unauthorized activations will void the system warranty and waive manufacturer supplied activation and final inspection. ® Filterra® Bioscape Vault Plant Palettes KEY: (refer to plant lists for species sizing) 4x4 Media Bay A. 3 A.5 A. 6 A. 6 A. 9 A. 12 A. 15 A. 20 B. 6 C. 3 D. 2 B. 1 B.2 B. 2 B. 2 B. 3 B. 3 B. 4 C. 1 C.1 C. 1 D. 1 D. 1 D. 1 D. 1 D. 1 C. 1 C. 2 C. 2 C. 2 4x6/6x4 Media Bay 4x8/8x4 & 4.5x7.83/7.83x4.5 Media Bay 6x6 Media Bay 6x8/8x6 Media Bay 6x10/10x6 & 8x8 Media Bay 6x12/12x6 Media Bay 7x13/13x7/12x8 & 14x8 Media Bay A. EXTRA SMALL GRASS • Up to 2’ mature spread • 1-2 gallon typical (1 gal. minimum) B. SMALL GRASS/SHRUB • 2’-4’ mature spread • 1-7 gallon typical C. MEDIUM SHRUB • 4’-6’ mature spread • 1-7 gallon typical D. LARGE SHRUB OR EXTRA LARGE SHRUB OR TREE • 6’ mature spread and greater, 30’ max. mature height • Up to 15 gallon maximum NOTE: For larger vaults and in-ground Filterra Bioscape systems, palettes can be scaled (i.e. Qty 6 of the 22x8 Palette can be used for a 1056 sf Filterra Bioscape). MIX & MATCH SUBSTITUTION OPTIONS: 1 Large Shrub or Extra Large Shrub or Tree • 2 Medium Shrubs • 4 Small Grass/SHrubs • 12 Extra Small Grasses 1 Medium Shrub • 2 Small Grass/Shrubs • 6 Extra Small Grasses 1 Small Grass/Shrub • 3 Extra Small Grasses Page 5 of 24 of 39 www.ContechES.com/filterra | 800-338-1122 * UNPREPARED SITE FEE NOTE: A charge of $1500.00 will be invoiced for each activation visit requested by customer where Contech determines that the site does not meet the conditions required for Activation AND/OR acceptable plants are not provided by the contractor. ONLY Contech authorized representatives can perform Activation of Filterra systems; unauthorized activations will void the system warranty and waive manufacturer supplied activation and final inspection. please enlarge font to 8 point size or larger as required by state law. please also ensure text is clear www.ContechES.com/filterra | 800-338-1122 19 Filterra Activation Package | Page 7 * UNPREPARED SITE FEE NOTE: A charge of $1500.00 will be invoiced for each activation visit requested by customer where Contech determines that the site does not meet the conditions required for Activation AND/OR acceptable plants are not provided by the contractor. ONLY Contech authorized representatives can perform Activation of Filterra systems; unauthorized activations will void the system warranty and waive manufacturer supplied activation and final inspection. ® A. 24 A. 28 A. 32 A. 36 B. 8 B. 8 B. 10 B. 10 C. 4 C. 4 C. 5 C. 5 D. 2 D. 2 D. 3 D. 3 16x8 & 15x9 Media Bay 18x8 Media Bay 20x8 Media Bay 22x8 Media Bay Page 5 of 25 of 39 www.ContechES.com/filterra | 800-338-1122 * UNPREPARED SITE FEE NOTE: A charge of $1500.00 will be invoiced for each activation visit requested by customer where Contech determines that the site does not meet the conditions required for Activation AND/OR acceptable plants are not provided by the contractor. ONLY Contech authorized representatives can perform Activation of Filterra systems; unauthorized activations will void the system warranty and waive manufacturer supplied activation and final inspection. please enlarge font to 8 point size or larger as required by state law. please also ensure text is clear Appendix 2 – Filterra® Tree Grate Opening Expansion Procedure The standard grates used on all Filterra configurations that employ Tree Grates are fabricated with a 6” opening that is designed with a breakaway section that can be removed, allowing the grate opening to be expanded to 12” as the tree matures and the trunk widens. The following tools are required to expand the opening: • Mini sledgehammer (3 lb. or greater) • Safety Glasses / Goggles The following guidelines should be followed to properly expand the tree opening from 6” to 12”: 1. Remove the grate from the Filterra frame, place it flat on a hard surface, and support the grate by stepping on the edge or using other weighted items such as a few mulch bags if this is being done during a Filterra maintenance event. Put on safety glasses/goggles. Align the mini sledgehammer as shown in the figure to the left. The head of the sledgehammer should be aimed just inside the wide cast iron bar between the larger grate section and the breakaway section. 2. Repeatedly hit the grate at this spot with the mini sledgehammer. 3. After several hits, the breakaway section should snap cleanly off of the larger grate section. Reinstall the grate into the Filterra grate frame. Recycle or dispose of the breakaway section per local guidelines. Page 5 of www.ContechES.com/filterra | 800-338-1122 Appendix 2 – Filterra® Tree Grate Opening Expansion Procedure The standard grates used on all Filterra configurations that employ Tree Grates are fabricated with a 6” opening that is designed with a breakaway section that can be removed, allowing the grate opening to be expanded to 12” as the tree matures and the trunk widens. The following tools are required to expand the opening: • Mini sledgehammer (3 lb. or greater) • Safety Glasses / Goggles The following guidelines should be followed to properly expand the tree opening from 6” to 12”: 1. Remove the grate from the Filterra frame, place it flat on a hard surface, and support the grate by stepping on the edge or using other weighted items such as a few mulch bags if this is being done during a Filterra maintenance event. Put on safety glasses/goggles. Align the mini sledgehammer as shown in the figure to the left. The head of the sledgehammer should be aimed just inside the wide cast iron bar between the larger grate section and the breakaway section. 2. Repeatedly hit the grate at this spot with the mini sledgehammer. 3. After several hits, the breakaway section should snap cleanly off of the larger grate section. Reinstall the grate into the Filterra grate frame. Recycle or dispose of the breakaway section per local guidelines. 26 of 39 Notes ___________________________________________________________________________________________________________ ___________________________________________________________________________________________________________ ___________________________________________________________________________________________________________ ___________________________________________________________________________________________________________ ___________________________________________________________________________________________________________ ___________________________________________________________________________________________________________ ___________________________________________________________________________________________________________ ___________________________________________________________________________________________________________ ___________________________________________________________________________________________________________ ___________________________________________________________________________________________________________ ___________________________________________________________________________________________________________ ___________________________________________________________________________________________________________ ___________________________________________________________________________________________________________ ___________________________________________________________________________________________________________ ___________________________________________________________________________________________________________ ___________________________________________________________________________________________________________ ___________________________________________________________________________________________________________ ___________________________________________________________________________________________________________ ___________________________________________________________________________________________________________ ___________________________________________________________________________________________________________ ___________________________________________________________________________________________________________ ___________________________________________________________________________________________________________ ___________________________________________________________________________________________________________ ___________________________________________________________________________________________________________ ___________________________________________________________________________________________________________ ___________________________________________________________________________________________________________ ___________________________________________________________________________________________________________ ___________________________________________________________________________________________________________ ___________________________________________________________________________________________________________ ___________________________________________________________________________________________________________ ___________________________________________________________________________________________________________ Page 5 of www.ContechES.com/filterra | 800-338-1122 27 of 39 Notes ___________________________________________________________________________________________________________ ___________________________________________________________________________________________________________ ___________________________________________________________________________________________________________ ___________________________________________________________________________________________________________ ___________________________________________________________________________________________________________ ___________________________________________________________________________________________________________ ___________________________________________________________________________________________________________ ___________________________________________________________________________________________________________ ___________________________________________________________________________________________________________ ___________________________________________________________________________________________________________ ___________________________________________________________________________________________________________ ___________________________________________________________________________________________________________ ___________________________________________________________________________________________________________ ___________________________________________________________________________________________________________ ___________________________________________________________________________________________________________ ___________________________________________________________________________________________________________ ___________________________________________________________________________________________________________ ___________________________________________________________________________________________________________ ___________________________________________________________________________________________________________ ___________________________________________________________________________________________________________ ___________________________________________________________________________________________________________ ___________________________________________________________________________________________________________ ___________________________________________________________________________________________________________ ___________________________________________________________________________________________________________ ___________________________________________________________________________________________________________ ___________________________________________________________________________________________________________ ___________________________________________________________________________________________________________ ___________________________________________________________________________________________________________ ___________________________________________________________________________________________________________ ___________________________________________________________________________________________________________ ___________________________________________________________________________________________________________ Notes ___________________________________________________________________________________________________________ ___________________________________________________________________________________________________________ ___________________________________________________________________________________________________________ ___________________________________________________________________________________________________________ ___________________________________________________________________________________________________________ ___________________________________________________________________________________________________________ ___________________________________________________________________________________________________________ ___________________________________________________________________________________________________________ ___________________________________________________________________________________________________________ ___________________________________________________________________________________________________________ ___________________________________________________________________________________________________________ ___________________________________________________________________________________________________________ ___________________________________________________________________________________________________________ ___________________________________________________________________________________________________________ ___________________________________________________________________________________________________________ ___________________________________________________________________________________________________________ ___________________________________________________________________________________________________________ ___________________________________________________________________________________________________________ ___________________________________________________________________________________________________________ ___________________________________________________________________________________________________________ ___________________________________________________________________________________________________________ ___________________________________________________________________________________________________________ ___________________________________________________________________________________________________________ ___________________________________________________________________________________________________________ ___________________________________________________________________________________________________________ ___________________________________________________________________________________________________________ ___________________________________________________________________________________________________________ ___________________________________________________________________________________________________________ ___________________________________________________________________________________________________________ ___________________________________________________________________________________________________________ ___________________________________________________________________________________________________________ 39Page 5 of 28 of Page 5 of www.ContechES.com/filterra | 800-338-1122 28 of 39 Notes ___________________________________________________________________________________________________________ ___________________________________________________________________________________________________________ ___________________________________________________________________________________________________________ ___________________________________________________________________________________________________________ ___________________________________________________________________________________________________________ ___________________________________________________________________________________________________________ ___________________________________________________________________________________________________________ ___________________________________________________________________________________________________________ ___________________________________________________________________________________________________________ ___________________________________________________________________________________________________________ ___________________________________________________________________________________________________________ ___________________________________________________________________________________________________________ ___________________________________________________________________________________________________________ ___________________________________________________________________________________________________________ ___________________________________________________________________________________________________________ ___________________________________________________________________________________________________________ ___________________________________________________________________________________________________________ ___________________________________________________________________________________________________________ ___________________________________________________________________________________________________________ ___________________________________________________________________________________________________________ ___________________________________________________________________________________________________________ ___________________________________________________________________________________________________________ ___________________________________________________________________________________________________________ ___________________________________________________________________________________________________________ ___________________________________________________________________________________________________________ ___________________________________________________________________________________________________________ ___________________________________________________________________________________________________________ ___________________________________________________________________________________________________________ ___________________________________________________________________________________________________________ ___________________________________________________________________________________________________________ ___________________________________________________________________________________________________________ Notes ___________________________________________________________________________________________________________ ___________________________________________________________________________________________________________ ___________________________________________________________________________________________________________ ___________________________________________________________________________________________________________ ___________________________________________________________________________________________________________ ___________________________________________________________________________________________________________ ___________________________________________________________________________________________________________ ___________________________________________________________________________________________________________ ___________________________________________________________________________________________________________ ___________________________________________________________________________________________________________ ___________________________________________________________________________________________________________ ___________________________________________________________________________________________________________ ___________________________________________________________________________________________________________ ___________________________________________________________________________________________________________ ___________________________________________________________________________________________________________ ___________________________________________________________________________________________________________ ___________________________________________________________________________________________________________ ___________________________________________________________________________________________________________ ___________________________________________________________________________________________________________ ___________________________________________________________________________________________________________ ___________________________________________________________________________________________________________ ___________________________________________________________________________________________________________ ___________________________________________________________________________________________________________ ___________________________________________________________________________________________________________ ___________________________________________________________________________________________________________ ___________________________________________________________________________________________________________ ___________________________________________________________________________________________________________ ___________________________________________________________________________________________________________ ___________________________________________________________________________________________________________ ___________________________________________________________________________________________________________ ___________________________________________________________________________________________________________ 39Page 5 of 28 of Page 5 of www.ContechES.com/filterra | 800-338-1122 29 of 39 Notes ___________________________________________________________________________________________________________ ___________________________________________________________________________________________________________ ___________________________________________________________________________________________________________ ___________________________________________________________________________________________________________ ___________________________________________________________________________________________________________ ___________________________________________________________________________________________________________ ___________________________________________________________________________________________________________ ___________________________________________________________________________________________________________ ___________________________________________________________________________________________________________ ___________________________________________________________________________________________________________ ___________________________________________________________________________________________________________ ___________________________________________________________________________________________________________ ___________________________________________________________________________________________________________ ___________________________________________________________________________________________________________ ___________________________________________________________________________________________________________ ___________________________________________________________________________________________________________ ___________________________________________________________________________________________________________ ___________________________________________________________________________________________________________ ___________________________________________________________________________________________________________ ___________________________________________________________________________________________________________ ___________________________________________________________________________________________________________ ___________________________________________________________________________________________________________ ___________________________________________________________________________________________________________ ___________________________________________________________________________________________________________ ___________________________________________________________________________________________________________ ___________________________________________________________________________________________________________ ___________________________________________________________________________________________________________ ___________________________________________________________________________________________________________ ___________________________________________________________________________________________________________ ___________________________________________________________________________________________________________ ___________________________________________________________________________________________________________ PDF 1/23 © 2023 Contech Engineered Solutions LLC, a QUIKRETE Company 9100 Centre Pointe Drive, Suite 400 West Chester, OH 45069 info@conteches.com | 800-338-1122 www.ContechES.com ALL RIGHTS RESERVED. PRINTED IN THE USA. NOTHING IN THIS CATALOG SHOULD BE CONSTRUED AS A WARRANTY. APPLICATIONS SUGGESTED HEREIN ARE DESCRIBED ONLY TO HELP READERS MAKE THEIR OWN EVALUATIONS AND DECISIONS, AND ARE NEITHER GUARANTEES NOR WARRANTIES OF SUITABILITY FOR ANY APPLICATION. CONTECH MAKES NO WARRANTY WHATSOEVER, EXPRESS OR IMPLIED, RELATED TO THE APPLICATIONS, MATERIALS, COATINGS, OR PRODUCTS DISCUSSED HEREIN. ALL IMPLIED WARRANTIES OF MERCHANTABILITY AND ALL IMPLIED WARRANTIES OF FITNESS FOR ANY PARTICULAR PURPOSE ARE DISCLAIMED BY CONTECH. SEE CONTECH’S CONDITIONS OF SALE (AVAILABLE AT WWW.CONTECHES.COM/COS) FOR MORE INFORMATION. ® Bioretention Systems ENGINEERED SOLUTIONS 39Page 5 of 28 of Page 5 of 30 of 39 PDF 1/23 © 2023 Contech Engineered Solutions LLC, a QUIKRETE Company 9100 Centre Pointe Drive, Suite 400 West Chester, OH 45069 info@conteches.com | 800-338-1122 www.ContechES.com ALL RIGHTS RESERVED. PRINTED IN THE USA. NOTHING IN THIS CATALOG SHOULD BE CONSTRUED AS A WARRANTY. APPLICATIONS SUGGESTED HEREIN ARE DESCRIBED ONLY TO HELP READERS MAKE THEIR OWN EVALUATIONS AND DECISIONS, AND ARE NEITHER GUARANTEES NOR WARRANTIES OF SUITABILITY FOR ANY APPLICATION. CONTECH MAKES NO WARRANTY WHATSOEVER, EXPRESS OR IMPLIED, RELATED TO THE APPLICATIONS, MATERIALS, COATINGS, OR PRODUCTS DISCUSSED HEREIN. ALL IMPLIED WARRANTIES OF MERCHANTABILITY AND ALL IMPLIED WARRANTIES OF FITNESS FOR ANY PARTICULAR PURPOSE ARE DISCLAIMED BY CONTECH. SEE CONTECH’S CONDITIONS OF SALE (AVAILABLE AT WWW.CONTECHES.COM/COS) FOR MORE INFORMATION. ® Bioretention Systems ENGINEERED SOLUTIONS NOTHING IN THIS CATALOG SHOULD BE CONSTRUED AS A WARRANTY. APPLICATIONS SUGGESTED HEREIN ARE DESCRIBED ONLY TO HELP READERS MAKE THEIR OWN EVALUATIONS AND DECISIONS, AND ARE NEITHER GUARANTEES NOR WARRANTIES OF SUITABILITY FOR ANY APPLICATION. CONTECH MAKES NO WARRANTY WHATSOEVER, EXPRESS OR IMPLIED, RELATED TO THE APPLICATIONS, MATERIALS, COATINGS, OR PRODUCTS DISCUSSED HEREIN. ALL IMPLIED WARRANTIES OF MERCHANTABILITY AND ALL IMPLIED WARRANTIES OF FITNESS FOR ANY PARTICULAR PURPOSE ARE DISCLAIMED BY CONTECH. SEE CONTECH’S CONDITIONS OF SALE (AVAILABLE AT WWW.CONTECHES.COM/COS) FOR MORE INFORMATION. © 2023 Contech Engineered Solutions LLC, a QUIKRETE Company ALL RIGHTS RESERVED. PRINTED IN THE USA. CDS Guide Operation, Design, Performance and Maintenance ENGINEERED SOLUTIONS 39Page 5 of 28 of Page 5 of 30 of 39 PDF 1/23 © 2023 Contech Engineered Solutions LLC, a QUIKRETE Company 9100 Centre Pointe Drive, Suite 400 West Chester, OH 45069 info@conteches.com | 800-338-1122 www.ContechES.com ALL RIGHTS RESERVED. PRINTED IN THE USA. NOTHING IN THIS CATALOG SHOULD BE CONSTRUED AS A WARRANTY. APPLICATIONS SUGGESTED HEREIN ARE DESCRIBED ONLY TO HELP READERS MAKE THEIR OWN EVALUATIONS AND DECISIONS, AND ARE NEITHER GUARANTEES NOR WARRANTIES OF SUITABILITY FOR ANY APPLICATION. CONTECH MAKES NO WARRANTY WHATSOEVER, EXPRESS OR IMPLIED, RELATED TO THE APPLICATIONS, MATERIALS, COATINGS, OR PRODUCTS DISCUSSED HEREIN. ALL IMPLIED WARRANTIES OF MERCHANTABILITY AND ALL IMPLIED WARRANTIES OF FITNESS FOR ANY PARTICULAR PURPOSE ARE DISCLAIMED BY CONTECH. SEE CONTECH’S CONDITIONS OF SALE (AVAILABLE AT WWW.CONTECHES.COM/COS) FOR MORE INFORMATION. ® Bioretention Systems ENGINEERED SOLUTIONS NOTHING IN THIS CATALOG SHOULD BE CONSTRUED AS A WARRANTY. APPLICATIONS SUGGESTED HEREIN ARE DESCRIBED ONLY TO HELP READERS MAKE THEIR OWN EVALUATIONS AND DECISIONS, AND ARE NEITHER GUARANTEES NOR WARRANTIES OF SUITABILITY FOR ANY APPLICATION. CONTECH MAKES NO WARRANTY WHATSOEVER, EXPRESS OR IMPLIED, RELATED TO THE APPLICATIONS, MATERIALS, COATINGS, OR PRODUCTS DISCUSSED HEREIN. ALL IMPLIED WARRANTIES OF MERCHANTABILITY AND ALL IMPLIED WARRANTIES OF FITNESS FOR ANY PARTICULAR PURPOSE ARE DISCLAIMED BY CONTECH. SEE CONTECH’S CONDITIONS OF SALE (AVAILABLE AT WWW.CONTECHES.COM/COS) FOR MORE INFORMATION. © 2023 Contech Engineered Solutions LLC, a QUIKRETE Company ALL RIGHTS RESERVED. PRINTED IN THE USA. 39Page 5 of 28 of Page 5 of 31 of 39 CDS Guide Operation, Design, Performance and Maintenance ENGINEERED SOLUTIONS 2 CDS® Using patented continuous deflective separation technology, the CDS system screens, separates and traps debris, sediment, and oil and grease from stormwater runoff. The indirect screening capability of the system allows for 100% removal of floatables and neutrally buoyant material without blinding. Flow and screening controls physically separate captured solids, and minimize the re-suspension and release of previously trapped pollutants. Inline units can treat up to 6 cfs, and internally bypass flows in excess of 50 cfs (1416 L/s). Available precast or cast-in- place, offline units can treat flows from 1 to 300 cfs (28.3 to 8495 L/s). The pollutant removal capacity of the CDS system has been proven in lab and field testing. Operation Overview Stormwater enters the diversion chamber where the diversion weir guides the flow into the unit’s separation chamber and pollutants are removed from the flow. All flows up to the system’s treatment design capacity enter the separation chamber and are treated. Swirl concentration and screen deflection force floatables and solids to the center of the separation chamber where 100% of floatables and neutrally buoyant debris larger than the screen apertures are trapped. Stormwater then moves through the separation screen, under the oil baffle and exits the system. The separation screen remains clog free due to continuous deflection. During the flow events exceeding the treatment design capacity, the diversion weir bypasses excessive flows around the separation chamber, so captured pollutants are retained in the separation cylinder. Design Basics There are three primary methods of sizing a CDS system. The Water Quality Flow Rate Method determines which model size provides the desired removal efficiency at a given flow rate for a defined particle size. The Rational Rainfall Method™ or the and Probabilistic Method is used when a specific removal efficiency of the net annual sediment load is required. Typically in the Unites States, CDS systems are designed to achieve an 80% annual solids load reduction based on lab generated performance curves for a gradation with an average particle size (d50) of 125 microns (μm). For some regulatory environments, CDS systems can also be designed to achieve an 80% annual solids load reduction based on an average particle size (d50) of 75 microns (μm) or 50 microns (μm). Water Quality Flow Rate Method In some cases, regulations require that a specific treatment rate, often referred to as the water quality design flow (WQQ), be treated. This WQQ represents the peak flow rate from either an event with a specific recurrence interval, e.g. the six-month storm, or a water quality depth, e.g. 1/2-inch (13 mm) of rainfall. The CDS is designed to treat all flows up to the WQQ. At influent rates higher than the WQQ, the diversion weir will direct most flow exceeding the WQQ around the separation chamber. This allows removal efficiency to remain relatively constant in the separation chamber and eliminates the risk of washout during bypass flows regardless of influent flow rates. Treatment flow rates are defined as the rate at which the CDS will remove a specific gradation of sediment at a specific removal efficiency. Therefore the treatment flow rate is variable, based on the gradation and removal efficiency specified by the design engineer. Rational Rainfall Method™ Differences in local climate, topography and scale make every site hydraulically unique. It is important to take these factors into consideration when estimating the long-term performance of any stormwater treatment system. The Rational Rainfall Method combines site-specific information with laboratory generated performance data, and local historical precipitation records to estimate removal efficiencies as accurately as possible. Short duration rain gauge records from across the United States and Canada were analyzed to determine the percent of the total annual rainfall that fell at a range of intensities. US stations’ depths were totaled every 15 minutes, or hourly, and recorded in 0.01-inch increments. Depths were recorded hourly with 1-mm resolution at Canadian stations. One trend was consistent at all sites; the vast majority of precipitation fell at low intensities and high intensity storms contributed relatively little to the total annual depth. These intensities, along with the total drainage area and runoff coefficient for each specific site, are translated into flow rates using the Rational Rainfall Method. Since most sites are relatively small and highly impervious, the Rational Rainfall Method is appropriate. Based on the runoff flow rates calculated for each intensity, operating rates within a proposed CDS system are GRATE INLET(CAST IRON HOOD FORCURB INLET OPENING) CREST OF BYPASS WEIR(ONE EACH SIDE) INLET(MULTIPLE PIPES POSSIBLE) OIL BAFFLE SUMP STORAGESEPARATION SLAB TREATMENT SCREEN OUTLET INLET FLUME SEPARATION CYLINDER CLEAN OUT(REQUIRED) DEFLECTION PAN, 3 SIDED(GRATE INLET DESIGN) 39Page 5 of 28 of Page 5 of 30 of 39 PDF 1/23 © 2023 Contech Engineered Solutions LLC, a QUIKRETE Company 9100 Centre Pointe Drive, Suite 400 West Chester, OH 45069 info@conteches.com | 800-338-1122 www.ContechES.com ALL RIGHTS RESERVED. PRINTED IN THE USA. NOTHING IN THIS CATALOG SHOULD BE CONSTRUED AS A WARRANTY. APPLICATIONS SUGGESTED HEREIN ARE DESCRIBED ONLY TO HELP READERS MAKE THEIR OWN EVALUATIONS AND DECISIONS, AND ARE NEITHER GUARANTEES NOR WARRANTIES OF SUITABILITY FOR ANY APPLICATION. CONTECH MAKES NO WARRANTY WHATSOEVER, EXPRESS OR IMPLIED, RELATED TO THE APPLICATIONS, MATERIALS, COATINGS, OR PRODUCTS DISCUSSED HEREIN. ALL IMPLIED WARRANTIES OF MERCHANTABILITY AND ALL IMPLIED WARRANTIES OF FITNESS FOR ANY PARTICULAR PURPOSE ARE DISCLAIMED BY CONTECH. SEE CONTECH’S CONDITIONS OF SALE (AVAILABLE AT WWW.CONTECHES.COM/COS) FOR MORE INFORMATION. ® Bioretention Systems ENGINEERED SOLUTIONS NOTHING IN THIS CATALOG SHOULD BE CONSTRUED AS A WARRANTY. APPLICATIONS SUGGESTED HEREIN ARE DESCRIBED ONLY TO HELP READERS MAKE THEIR OWN EVALUATIONS AND DECISIONS, AND ARE NEITHER GUARANTEES NOR WARRANTIES OF SUITABILITY FOR ANY APPLICATION. CONTECH MAKES NO WARRANTY WHATSOEVER, EXPRESS OR IMPLIED, RELATED TO THE APPLICATIONS, MATERIALS, COATINGS, OR PRODUCTS DISCUSSED HEREIN. ALL IMPLIED WARRANTIES OF MERCHANTABILITY AND ALL IMPLIED WARRANTIES OF FITNESS FOR ANY PARTICULAR PURPOSE ARE DISCLAIMED BY CONTECH. SEE CONTECH’S CONDITIONS OF SALE (AVAILABLE AT WWW.CONTECHES.COM/COS) FOR MORE INFORMATION. © 2023 Contech Engineered Solutions LLC, a QUIKRETE Company ALL RIGHTS RESERVED. PRINTED IN THE USA. 39Page 5 of 28 of Page 5 of 32 of 39 2 CDS® Using patented continuous deflective separation technology, the CDS system screens, separates and traps debris, sediment, and oil and grease from stormwater runoff. The indirect screening capability of the system allows for 100% removal of floatables and neutrally buoyant material without blinding. Flow and screening controls physically separate captured solids, and minimize the re-suspension and release of previously trapped pollutants. Inline units can treat up to 6 cfs, and internally bypass flows in excess of 50 cfs (1416 L/s). Available precast or cast-in- place, offline units can treat flows from 1 to 300 cfs (28.3 to 8495 L/s). The pollutant removal capacity of the CDS system has been proven in lab and field testing. Operation Overview Stormwater enters the diversion chamber where the diversion weir guides the flow into the unit’s separation chamber and pollutants are removed from the flow. All flows up to the system’s treatment design capacity enter the separation chamber and are treated. Swirl concentration and screen deflection force floatables and solids to the center of the separation chamber where 100% of floatables and neutrally buoyant debris larger than the screen apertures are trapped. Stormwater then moves through the separation screen, under the oil baffle and exits the system. The separation screen remains clog free due to continuous deflection. During the flow events exceeding the treatment design capacity, the diversion weir bypasses excessive flows around the separation chamber, so captured pollutants are retained in the separation cylinder. Design Basics There are three primary methods of sizing a CDS system. The Water Quality Flow Rate Method determines which model size provides the desired removal efficiency at a given flow rate for a defined particle size. The Rational Rainfall Method™ or the and Probabilistic Method is used when a specific removal efficiency of the net annual sediment load is required. Typically in the Unites States, CDS systems are designed to achieve an 80% annual solids load reduction based on lab generated performance curves for a gradation with an average particle size (d50) of 125 microns (μm). For some regulatory environments, CDS systems can also be designed to achieve an 80% annual solids load reduction based on an average particle size (d50) of 75 microns (μm) or 50 microns (μm). Water Quality Flow Rate Method In some cases, regulations require that a specific treatment rate, often referred to as the water quality design flow (WQQ), be treated. This WQQ represents the peak flow rate from either an event with a specific recurrence interval, e.g. the six-month storm, or a water quality depth, e.g. 1/2-inch (13 mm) of rainfall. The CDS is designed to treat all flows up to the WQQ. At influent rates higher than the WQQ, the diversion weir will direct most flow exceeding the WQQ around the separation chamber. This allows removal efficiency to remain relatively constant in the separation chamber and eliminates the risk of washout during bypass flows regardless of influent flow rates. Treatment flow rates are defined as the rate at which the CDS will remove a specific gradation of sediment at a specific removal efficiency. Therefore the treatment flow rate is variable, based on the gradation and removal efficiency specified by the design engineer. Rational Rainfall Method™ Differences in local climate, topography and scale make every site hydraulically unique. It is important to take these factors into consideration when estimating the long-term performance of any stormwater treatment system. The Rational Rainfall Method combines site-specific information with laboratory generated performance data, and local historical precipitation records to estimate removal efficiencies as accurately as possible. Short duration rain gauge records from across the United States and Canada were analyzed to determine the percent of the total annual rainfall that fell at a range of intensities. US stations’ depths were totaled every 15 minutes, or hourly, and recorded in 0.01-inch increments. Depths were recorded hourly with 1-mm resolution at Canadian stations. One trend was consistent at all sites; the vast majority of precipitation fell at low intensities and high intensity storms contributed relatively little to the total annual depth. These intensities, along with the total drainage area and runoff coefficient for each specific site, are translated into flow rates using the Rational Rainfall Method. Since most sites are relatively small and highly impervious, the Rational Rainfall Method is appropriate. Based on the runoff flow rates calculated for each intensity, operating rates within a proposed CDS system are GRATE INLET(CAST IRON HOOD FORCURB INLET OPENING) CREST OF BYPASS WEIR(ONE EACH SIDE) INLET(MULTIPLE PIPES POSSIBLE) OIL BAFFLE SUMP STORAGESEPARATION SLAB TREATMENT SCREEN OUTLET INLET FLUME SEPARATION CYLINDER CLEAN OUT(REQUIRED) DEFLECTION PAN, 3 SIDED(GRATE INLET DESIGN) please enlarge text size to 8 point font size or larger 3 determined. Performance efficiency curve determined from full scale laboratory tests on defined sediment PSDs is applied to calculate solids removal efficiency. The relative removal efficiency at each operating rate is added to produce a net annual pollutant removal efficiency estimate. Probabilistic Rational Method The Probabilistic Rational Method is a sizing program Contech developed to estimate a net annual sediment load reduction for a particular CDS model based on site size, site runoff coefficient, regional rainfall intensity distribution, and anticipated pollutant characteristics. The Probabilistic Method is an extension of the Rational Method used to estimate peak discharge rates generated by storm events of varying statistical return frequencies (e.g. 2-year storm event). Under the Rational Method, an adjustment factor is used to adjust the runoff coefficient estimated for the 10-year event, correlating a known hydrologic parameter with the target storm event. The rainfall intensities vary depending on the return frequency of the storm event under consideration. In general, these two frequency dependent parameters (rainfall intensity and runoff coefficient) increase as the return frequency increases while the drainage area remains constant. These intensities, along with the total drainage area and runoff coefficient for each specific site, are translated into flow rates using the Rational Method. Since most sites are relatively small and highly impervious, the Rational Method is appropriate. Based on the runoff flow rates calculated for each intensity, operating rates within a proposed CDS are determined. Performance efficiency curve on defined sediment PSDs is applied to calculate solids removal efficiency. The relative removal efficiency at each operating rate is added to produce a net annual pollutant removal efficiency estimate. Treatment Flow Rate The inlet throat area is sized to ensure that the WQQ passes through the separation chamber at a water surface elevation equal to the crest of the diversion weir. The diversion weir bypasses excessive flows around the separation chamber, thus preventing re-suspension or re-entrainment of previously captured particles. Hydraulic Capacity The hydraulic capacity of a CDS system is determined by the length and height of the diversion weir and by the maximum allowable head in the system. Typical configurations allow hydraulic capacities of up to ten times the treatment flow rate. The crest of the diversion weir may be lowered and the inlet throat may be widened to increase the capacity of the system at a given water surface elevation. The unit is designed to meet project specific hydraulic requirements. Performance Full-Scale Laboratory Test Results A full-scale CDS system (Model CDS2020-5B) was tested at the facility of University of Florida, Gainesville, FL. This CDS unit was evaluated under controlled laboratory conditions of influent flow rate and addition of sediment. Two different gradations of silica sand material (UF Sediment & OK-110) were used in the CDS performance evaluation. The particle size distributions (PSDs) of the test materials were analyzed using standard method “Gradation ASTM D-422 “Standard Test Method for Particle-Size Analysis of Soils” by a certified laboratory. UF Sediment is a mixture of three different products produced by the U.S. Silica Company: “Sil-Co-Sil 106”, “#1 DRY” and “20/40 Oil Frac”. Particle size distribution analysis shows that the UF Sediment has a very fine gradation (d50 = 20 to 30 μm) covering a wide size range (Coefficient of Uniformity, C averaged at 10.6). In comparison with the hypothetical TSS gradation specified in the NJDEP (New Jersey Department of Environmental Protection) and NJCAT (New Jersey Corporation for Advanced Technology) protocol for lab testing, the UF Sediment covers a similar range of particle size but with a finer d50 (d50 for NJDEP is approximately 50 μm) (NJDEP, 2003). The OK-110 silica sand is a commercial product of U.S. Silica Sand. The particle size distribution analysis of this material, also included in Figure 1, shows that 99.9% of the OK-110 sand is finer than 250 microns, with a mean particle size (d50) of 106 microns. The PSDs for the test material are shown in Figure 1. Figure 1. Particle size distributions Tests were conducted to quantify the performance of a specific CDS unit (1.1 cfs (31.3-L/s) design capacity) at various flow rates, ranging from 1% up to 125% of the treatment design capacity of the unit, using the 2400 micron screen. All tests were conducted with controlled influent concentrations of approximately 200 mg/L. Effluent samples were taken at equal time intervals across the entire duration of each test run. These samples were then processed with a Dekaport Cone sample splitter to obtain representative sub-samples for Suspended Sediment Concentration (SSC) testing using ASTM D3977-97 “Standard Test Methods for Determining Sediment Concentration in Water Samples”, and particle size distribution analysis. Results and Modeling Based on the data from the University of Florida, a performance model was developed for the CDS system. A regression analysis was used to develop a fitting curve representative of the scattered data points at various design flow rates. This model, which demonstrated good agreement with the laboratory data, can then be used to predict CDS system performance with respect Page 5 of 30 of 39 PDF 1/23 © 2023 Contech Engineered Solutions LLC, a QUIKRETE Company 9100 Centre Pointe Drive, Suite 400 West Chester, OH 45069 info@conteches.com | 800-338-1122 www.ContechES.com ALL RIGHTS RESERVED. PRINTED IN THE USA. NOTHING IN THIS CATALOG SHOULD BE CONSTRUED AS A WARRANTY. APPLICATIONS SUGGESTED HEREIN ARE DESCRIBED ONLY TO HELP READERS MAKE THEIR OWN EVALUATIONS AND DECISIONS, AND ARE NEITHER GUARANTEES NOR WARRANTIES OF SUITABILITY FOR ANY APPLICATION. CONTECH MAKES NO WARRANTY WHATSOEVER, EXPRESS OR IMPLIED, RELATED TO THE APPLICATIONS, MATERIALS, COATINGS, OR PRODUCTS DISCUSSED HEREIN. ALL IMPLIED WARRANTIES OF MERCHANTABILITY AND ALL IMPLIED WARRANTIES OF FITNESS FOR ANY PARTICULAR PURPOSE ARE DISCLAIMED BY CONTECH. SEE CONTECH’S CONDITIONS OF SALE (AVAILABLE AT WWW.CONTECHES.COM/COS) FOR MORE INFORMATION. ® Bioretention Systems ENGINEERED SOLUTIONS NOTHING IN THIS CATALOG SHOULD BE CONSTRUED AS A WARRANTY. APPLICATIONS SUGGESTED HEREIN ARE DESCRIBED ONLY TO HELP READERS MAKE THEIR OWN EVALUATIONS AND DECISIONS, AND ARE NEITHER GUARANTEES NOR WARRANTIES OF SUITABILITY FOR ANY APPLICATION. CONTECH MAKES NO WARRANTY WHATSOEVER, EXPRESS OR IMPLIED, RELATED TO THE APPLICATIONS, MATERIALS, COATINGS, OR PRODUCTS DISCUSSED HEREIN. ALL IMPLIED WARRANTIES OF MERCHANTABILITY AND ALL IMPLIED WARRANTIES OF FITNESS FOR ANY PARTICULAR PURPOSE ARE DISCLAIMED BY CONTECH. SEE CONTECH’S CONDITIONS OF SALE (AVAILABLE AT WWW.CONTECHES.COM/COS) FOR MORE INFORMATION. © 2023 Contech Engineered Solutions LLC, a QUIKRETE Company ALL RIGHTS RESERVED. PRINTED IN THE USA. 39Page 5 of 28 of Page 5 of 33 of 39 3 determined. Performance efficiency curve determined from full scale laboratory tests on defined sediment PSDs is applied to calculate solids removal efficiency. The relative removal efficiency at each operating rate is added to produce a net annual pollutant removal efficiency estimate. Probabilistic Rational Method The Probabilistic Rational Method is a sizing program Contech developed to estimate a net annual sediment load reduction for a particular CDS model based on site size, site runoff coefficient, regional rainfall intensity distribution, and anticipated pollutant characteristics. The Probabilistic Method is an extension of the Rational Method used to estimate peak discharge rates generated by storm events of varying statistical return frequencies (e.g. 2-year storm event). Under the Rational Method, an adjustment factor is used to adjust the runoff coefficient estimated for the 10-year event, correlating a known hydrologic parameter with the target storm event. The rainfall intensities vary depending on the return frequency of the storm event under consideration. In general, these two frequency dependent parameters (rainfall intensity and runoff coefficient) increase as the return frequency increases while the drainage area remains constant. These intensities, along with the total drainage area and runoff coefficient for each specific site, are translated into flow rates using the Rational Method. Since most sites are relatively small and highly impervious, the Rational Method is appropriate. Based on the runoff flow rates calculated for each intensity, operating rates within a proposed CDS are determined. Performance efficiency curve on defined sediment PSDs is applied to calculate solids removal efficiency. The relative removal efficiency at each operating rate is added to produce a net annual pollutant removal efficiency estimate. Treatment Flow Rate The inlet throat area is sized to ensure that the WQQ passes through the separation chamber at a water surface elevation equal to the crest of the diversion weir. The diversion weir bypasses excessive flows around the separation chamber, thus preventing re-suspension or re-entrainment of previously captured particles. Hydraulic Capacity The hydraulic capacity of a CDS system is determined by the length and height of the diversion weir and by the maximum allowable head in the system. Typical configurations allow hydraulic capacities of up to ten times the treatment flow rate. The crest of the diversion weir may be lowered and the inlet throat may be widened to increase the capacity of the system at a given water surface elevation. The unit is designed to meet project specific hydraulic requirements. Performance Full-Scale Laboratory Test Results A full-scale CDS system (Model CDS2020-5B) was tested at the facility of University of Florida, Gainesville, FL. This CDS unit was evaluated under controlled laboratory conditions of influent flow rate and addition of sediment. Two different gradations of silica sand material (UF Sediment & OK-110) were used in the CDS performance evaluation. The particle size distributions (PSDs) of the test materials were analyzed using standard method “Gradation ASTM D-422 “Standard Test Method for Particle-Size Analysis of Soils” by a certified laboratory. UF Sediment is a mixture of three different products produced by the U.S. Silica Company: “Sil-Co-Sil 106”, “#1 DRY” and “20/40 Oil Frac”. Particle size distribution analysis shows that the UF Sediment has a very fine gradation (d50 = 20 to 30 μm) covering a wide size range (Coefficient of Uniformity, C averaged at 10.6). In comparison with the hypothetical TSS gradation specified in the NJDEP (New Jersey Department of Environmental Protection) and NJCAT (New Jersey Corporation for Advanced Technology) protocol for lab testing, the UF Sediment covers a similar range of particle size but with a finer d50 (d50 for NJDEP is approximately 50 μm) (NJDEP, 2003). The OK-110 silica sand is a commercial product of U.S. Silica Sand. The particle size distribution analysis of this material, also included in Figure 1, shows that 99.9% of the OK-110 sand is finer than 250 microns, with a mean particle size (d50) of 106 microns. The PSDs for the test material are shown in Figure 1. Figure 1. Particle size distributions Tests were conducted to quantify the performance of a specific CDS unit (1.1 cfs (31.3-L/s) design capacity) at various flow rates, ranging from 1% up to 125% of the treatment design capacity of the unit, using the 2400 micron screen. All tests were conducted with controlled influent concentrations of approximately 200 mg/L. Effluent samples were taken at equal time intervals across the entire duration of each test run. These samples were then processed with a Dekaport Cone sample splitter to obtain representative sub-samples for Suspended Sediment Concentration (SSC) testing using ASTM D3977-97 “Standard Test Methods for Determining Sediment Concentration in Water Samples”, and particle size distribution analysis. Results and Modeling Based on the data from the University of Florida, a performance model was developed for the CDS system. A regression analysis was used to develop a fitting curve representative of the scattered data points at various design flow rates. This model, which demonstrated good agreement with the laboratory data, can then be used to predict CDS system performance with respect please enlarge text size to 8 point font size or larger 4 to SSC removal for any particle size gradation, assuming the particles are inorganic sandy-silt. Figure 2 shows CDS predictive performance for two typical particle size gradations (NJCAT gradation and OK-110 sand) as a function of operating rate. Figure 2. CDS stormwater treatment predictive performance for various particle gradations as a function of operating rate. Many regulatory jurisdictions set a performance standard for hydrodynamic devices by stating that the devices shall be capable of achieving an 80% removal efficiency for particles having a mean particle size (d50) of 125 microns (e.g. Washington State Department of Ecology — WASDOE - 2008). The model can be used to calculate the expected performance of such a PSD (shown in Figure 3). The model indicates (Figure 4) that the CDS system with 2400 micron screen achieves approximately 80% removal at the design (100%) flow rate, for this particle size distribution (d50 = 125 μm). Figure 3. WASDOE PSD Figure 4. Modeled performance for WASDOE PSD. Maintenance The CDS system should be inspected at regular intervals and maintained when necessary to ensure optimum performance. The rate at which the system collects pollutants will depend more heavily on site activities than the size of the unit. For example, unstable soils or heavy winter sanding will cause the grit chamber to fill more quickly but regular sweeping of paved surfaces will slow accumulation. Inspection Inspection is the key to effective maintenance and is easily performed. Pollutant transport and deposition may vary from year to year and regular inspections will help ensure that the system is cleaned out at the appropriate time. At a minimum, inspections should be performed twice per year (e.g. spring and fall) however more frequent inspections may be necessary in climates where winter sanding operations may lead to rapid accumulations, or in equipment washdown areas. Installations should also be inspected more frequently where excessive amounts of trash are expected. The visual inspection should ascertain that the system components are in working order and that there are no blockages or obstructions in the inlet and separation screen. The inspection should also quantify the accumulation of hydrocarbons, trash, and sediment in the system. Measuring pollutant accumulation can be done with a calibrated dipstick, tape measure or other measuring instrument. If absorbent material is used for enhanced removal of hydrocarbons, the level of discoloration of the sorbent material should also be identified Page 5 of 30 of 39 PDF 1/23 © 2023 Contech Engineered Solutions LLC, a QUIKRETE Company 9100 Centre Pointe Drive, Suite 400 West Chester, OH 45069 info@conteches.com | 800-338-1122 www.ContechES.com ALL RIGHTS RESERVED. PRINTED IN THE USA. NOTHING IN THIS CATALOG SHOULD BE CONSTRUED AS A WARRANTY. APPLICATIONS SUGGESTED HEREIN ARE DESCRIBED ONLY TO HELP READERS MAKE THEIR OWN EVALUATIONS AND DECISIONS, AND ARE NEITHER GUARANTEES NOR WARRANTIES OF SUITABILITY FOR ANY APPLICATION. CONTECH MAKES NO WARRANTY WHATSOEVER, EXPRESS OR IMPLIED, RELATED TO THE APPLICATIONS, MATERIALS, COATINGS, OR PRODUCTS DISCUSSED HEREIN. ALL IMPLIED WARRANTIES OF MERCHANTABILITY AND ALL IMPLIED WARRANTIES OF FITNESS FOR ANY PARTICULAR PURPOSE ARE DISCLAIMED BY CONTECH. SEE CONTECH’S CONDITIONS OF SALE (AVAILABLE AT WWW.CONTECHES.COM/COS) FOR MORE INFORMATION. ® Bioretention Systems ENGINEERED SOLUTIONS NOTHING IN THIS CATALOG SHOULD BE CONSTRUED AS A WARRANTY. APPLICATIONS SUGGESTED HEREIN ARE DESCRIBED ONLY TO HELP READERS MAKE THEIR OWN EVALUATIONS AND DECISIONS, AND ARE NEITHER GUARANTEES NOR WARRANTIES OF SUITABILITY FOR ANY APPLICATION. CONTECH MAKES NO WARRANTY WHATSOEVER, EXPRESS OR IMPLIED, RELATED TO THE APPLICATIONS, MATERIALS, COATINGS, OR PRODUCTS DISCUSSED HEREIN. ALL IMPLIED WARRANTIES OF MERCHANTABILITY AND ALL IMPLIED WARRANTIES OF FITNESS FOR ANY PARTICULAR PURPOSE ARE DISCLAIMED BY CONTECH. SEE CONTECH’S CONDITIONS OF SALE (AVAILABLE AT WWW.CONTECHES.COM/COS) FOR MORE INFORMATION. © 2023 Contech Engineered Solutions LLC, a QUIKRETE Company ALL RIGHTS RESERVED. PRINTED IN THE USA. 39Page 5 of 28 of Page 5 of 34 of 39 4 to SSC removal for any particle size gradation, assuming the particles are inorganic sandy-silt. Figure 2 shows CDS predictive performance for two typical particle size gradations (NJCAT gradation and OK-110 sand) as a function of operating rate. Figure 2. CDS stormwater treatment predictive performance for various particle gradations as a function of operating rate. Many regulatory jurisdictions set a performance standard for hydrodynamic devices by stating that the devices shall be capable of achieving an 80% removal efficiency for particles having a mean particle size (d50) of 125 microns (e.g. Washington State Department of Ecology — WASDOE - 2008). The model can be used to calculate the expected performance of such a PSD (shown in Figure 3). The model indicates (Figure 4) that the CDS system with 2400 micron screen achieves approximately 80% removal at the design (100%) flow rate, for this particle size distribution (d50 = 125 μm). Figure 3. WASDOE PSD Figure 4. Modeled performance for WASDOE PSD. Maintenance The CDS system should be inspected at regular intervals and maintained when necessary to ensure optimum performance. The rate at which the system collects pollutants will depend more heavily on site activities than the size of the unit. For example, unstable soils or heavy winter sanding will cause the grit chamber to fill more quickly but regular sweeping of paved surfaces will slow accumulation. Inspection Inspection is the key to effective maintenance and is easily performed. Pollutant transport and deposition may vary from year to year and regular inspections will help ensure that the system is cleaned out at the appropriate time. At a minimum, inspections should be performed twice per year (e.g. spring and fall) however more frequent inspections may be necessary in climates where winter sanding operations may lead to rapid accumulations, or in equipment washdown areas. Installations should also be inspected more frequently where excessive amounts of trash are expected. The visual inspection should ascertain that the system components are in working order and that there are no blockages or obstructions in the inlet and separation screen. The inspection should also quantify the accumulation of hydrocarbons, trash, and sediment in the system. Measuring pollutant accumulation can be done with a calibrated dipstick, tape measure or other measuring instrument. If absorbent material is used for enhanced removal of hydrocarbons, the level of discoloration of the sorbent material should also be identified please enlarge text size to 8 point font size or larger 5 during inspection. It is useful and often required as part of an operating permit to keep a record of each inspection. A simple form for doing so is provided. Access to the CDS unit is typically achieved through two manhole access covers. One opening allows for inspection and cleanout of the separation chamber (cylinder and screen) and isolated sump. The other allows for inspection and cleanout of sediment captured and retained outside the screen. For deep units, a single manhole access point would allows both sump cleanout and access outside the screen. The CDS system should be cleaned when the level of sediment has reached 75% of capacity in the isolated sump or when an appreciable level of hydrocarbons and trash has accumulated. If absorbent material is used, it should be replaced when significant discoloration has occurred. Performance will not be impacted until 100% of the sump capacity is exceeded however it is recommended that the system be cleaned prior to that for easier removal of sediment. The level of sediment is easily determined by measuring from finished grade down to the top of the sediment pile. To avoid underestimating the level of sediment in the chamber, the measuring device must be lowered to the top of the sediment pile carefully. Particles at the top of the pile typically offer less resistance to the end of the rod than consolidated particles toward the bottom of the pile. Once this measurement is recorded, it should be compared to the as-built drawing for the unit to determine weather the height of the sediment pile off the bottom of the sump floor exceeds 75% of the total height of isolated sump. Cleaning Cleaning of a CDS systems should be done during dry weather conditions when no flow is entering the system. The use of a vacuum truck is generally the most effective and convenient method of removing pollutants from the system. Simply remove the manhole covers and insert the vacuum hose into the sump. The system should be completely drained down and the sump fully evacuated of sediment. The area outside the screen should also be cleaned out if pollutant build-up exists in this area. In installations where the risk of petroleum spills is small, liquid contaminants may not accumulate as quickly as sediment. However, the system should be cleaned out immediately in the event of an oil or gasoline spill. Motor oil and other hydrocarbons that accumulate on a more routine basis should be removed when an appreciable layer has been captured. To remove these pollutants, it may be preferable to use absorbent pads since they are usually less expensive to dispose than the oil/water emulsion that may be created by vacuuming the oily layer. Trash and debris can be netted out to separate it from the other pollutants. The screen should be cleaned to ensure it is free of trash and debris. Manhole covers should be securely seated following cleaning activities to prevent leakage of runoff into the system from above and also to ensure that proper safety precautions have been followed. Confined space entry procedures need to be followed if physical access is required. Disposal of all material removed from the CDS system should be done in accordance with local regulations. In many jurisdictions, disposal of the sediments may be handled in the same manner as the disposal of sediments removed from catch basins or deep sump manholes. Check your local regulations for specific requirements on disposal. Page 5 of 30 of 39 PDF 1/23 © 2023 Contech Engineered Solutions LLC, a QUIKRETE Company 9100 Centre Pointe Drive, Suite 400 West Chester, OH 45069 info@conteches.com | 800-338-1122 www.ContechES.com ALL RIGHTS RESERVED. PRINTED IN THE USA. NOTHING IN THIS CATALOG SHOULD BE CONSTRUED AS A WARRANTY. APPLICATIONS SUGGESTED HEREIN ARE DESCRIBED ONLY TO HELP READERS MAKE THEIR OWN EVALUATIONS AND DECISIONS, AND ARE NEITHER GUARANTEES NOR WARRANTIES OF SUITABILITY FOR ANY APPLICATION. CONTECH MAKES NO WARRANTY WHATSOEVER, EXPRESS OR IMPLIED, RELATED TO THE APPLICATIONS, MATERIALS, COATINGS, OR PRODUCTS DISCUSSED HEREIN. ALL IMPLIED WARRANTIES OF MERCHANTABILITY AND ALL IMPLIED WARRANTIES OF FITNESS FOR ANY PARTICULAR PURPOSE ARE DISCLAIMED BY CONTECH. SEE CONTECH’S CONDITIONS OF SALE (AVAILABLE AT WWW.CONTECHES.COM/COS) FOR MORE INFORMATION. ® Bioretention Systems ENGINEERED SOLUTIONS NOTHING IN THIS CATALOG SHOULD BE CONSTRUED AS A WARRANTY. APPLICATIONS SUGGESTED HEREIN ARE DESCRIBED ONLY TO HELP READERS MAKE THEIR OWN EVALUATIONS AND DECISIONS, AND ARE NEITHER GUARANTEES NOR WARRANTIES OF SUITABILITY FOR ANY APPLICATION. CONTECH MAKES NO WARRANTY WHATSOEVER, EXPRESS OR IMPLIED, RELATED TO THE APPLICATIONS, MATERIALS, COATINGS, OR PRODUCTS DISCUSSED HEREIN. ALL IMPLIED WARRANTIES OF MERCHANTABILITY AND ALL IMPLIED WARRANTIES OF FITNESS FOR ANY PARTICULAR PURPOSE ARE DISCLAIMED BY CONTECH. SEE CONTECH’S CONDITIONS OF SALE (AVAILABLE AT WWW.CONTECHES.COM/COS) FOR MORE INFORMATION. © 2023 Contech Engineered Solutions LLC, a QUIKRETE Company ALL RIGHTS RESERVED. PRINTED IN THE USA. 39Page 5 of 28 of Page 5 of 35 of 39 5 during inspection. It is useful and often required as part of an operating permit to keep a record of each inspection. A simple form for doing so is provided. Access to the CDS unit is typically achieved through two manhole access covers. One opening allows for inspection and cleanout of the separation chamber (cylinder and screen) and isolated sump. The other allows for inspection and cleanout of sediment captured and retained outside the screen. For deep units, a single manhole access point would allows both sump cleanout and access outside the screen. The CDS system should be cleaned when the level of sediment has reached 75% of capacity in the isolated sump or when an appreciable level of hydrocarbons and trash has accumulated. If absorbent material is used, it should be replaced when significant discoloration has occurred. Performance will not be impacted until 100% of the sump capacity is exceeded however it is recommended that the system be cleaned prior to that for easier removal of sediment. The level of sediment is easily determined by measuring from finished grade down to the top of the sediment pile. To avoid underestimating the level of sediment in the chamber, the measuring device must be lowered to the top of the sediment pile carefully. Particles at the top of the pile typically offer less resistance to the end of the rod than consolidated particles toward the bottom of the pile. Once this measurement is recorded, it should be compared to the as-built drawing for the unit to determine weather the height of the sediment pile off the bottom of the sump floor exceeds 75% of the total height of isolated sump. Cleaning Cleaning of a CDS systems should be done during dry weather conditions when no flow is entering the system. The use of a vacuum truck is generally the most effective and convenient method of removing pollutants from the system. Simply remove the manhole covers and insert the vacuum hose into the sump. The system should be completely drained down and the sump fully evacuated of sediment. The area outside the screen should also be cleaned out if pollutant build-up exists in this area. In installations where the risk of petroleum spills is small, liquid contaminants may not accumulate as quickly as sediment. However, the system should be cleaned out immediately in the event of an oil or gasoline spill. Motor oil and other hydrocarbons that accumulate on a more routine basis should be removed when an appreciable layer has been captured. To remove these pollutants, it may be preferable to use absorbent pads since they are usually less expensive to dispose than the oil/water emulsion that may be created by vacuuming the oily layer. Trash and debris can be netted out to separate it from the other pollutants. The screen should be cleaned to ensure it is free of trash and debris. Manhole covers should be securely seated following cleaning activities to prevent leakage of runoff into the system from above and also to ensure that proper safety precautions have been followed. Confined space entry procedures need to be followed if physical access is required. Disposal of all material removed from the CDS system should be done in accordance with local regulations. In many jurisdictions, disposal of the sediments may be handled in the same manner as the disposal of sediments removed from catch basins or deep sump manholes. Check your local regulations for specific requirements on disposal. please enlarge text size to 8 point font size or larger 6 Note: To avoid underestimating the volume of sediment in the chamber, carefully lower the measuring device to the top of the sediment pile. Finer silty particles at the top of the pile may be more difficult to feel with a measuring stick. These finer particles typically offer less resistance to the end of the rod than larger particles toward the bottom of the pile. CDS Model Diameter Distance from Water Surface to Top of Sediment Pile Sediment Storage Capacity ft m ft m y3 m3 CDS1515 3 0.9 3.0 0.9 0.5 0.4 CDS2015 4 1.2 3.0 0.9 0.9 0.7 CDS2015 5 1.5 3.0 0.9 1.3 1.0 CDS2020 5 1.5 3.5 1.1 1.3 1.0 CDS2025 5 1.5 4.0 1.2 1.3 1.0 CDS3020 6 1.8 4.0 1.2 2.1 1.6 CDS3025 6 1.8 4.0 1.2 2.1 1.6 CDS3030 6 1.8 4.6 1.4 2.1 1.6 CDS3035 6 1.8 5.0 1.5 2.1 1.6 CDS4030 8 2.4 4.6 1.4 5.6 4.3 CDS4040 8 2.4 5.7 1.7 5.6 4.3 CDS4045 8 2.4 6.2 1.9 5.6 4.3 CDS5640 10 3.0 6.3 1.9 8.7 6.7 CDS5653 10 3.0 7.7 2.3 8.7 6.7 CDS5668 10 3.0 9.3 2.8 8.7 6.7 CDS5678 10 3.0 10.3 3.1 8.7 6.7 Table 1: CDS Maintenance Indicators and Sediment Storage Capacities Page 5 of 30 of 39 PDF 1/23 © 2023 Contech Engineered Solutions LLC, a QUIKRETE Company 9100 Centre Pointe Drive, Suite 400 West Chester, OH 45069 info@conteches.com | 800-338-1122 www.ContechES.com ALL RIGHTS RESERVED. PRINTED IN THE USA. NOTHING IN THIS CATALOG SHOULD BE CONSTRUED AS A WARRANTY. APPLICATIONS SUGGESTED HEREIN ARE DESCRIBED ONLY TO HELP READERS MAKE THEIR OWN EVALUATIONS AND DECISIONS, AND ARE NEITHER GUARANTEES NOR WARRANTIES OF SUITABILITY FOR ANY APPLICATION. CONTECH MAKES NO WARRANTY WHATSOEVER, EXPRESS OR IMPLIED, RELATED TO THE APPLICATIONS, MATERIALS, COATINGS, OR PRODUCTS DISCUSSED HEREIN. ALL IMPLIED WARRANTIES OF MERCHANTABILITY AND ALL IMPLIED WARRANTIES OF FITNESS FOR ANY PARTICULAR PURPOSE ARE DISCLAIMED BY CONTECH. SEE CONTECH’S CONDITIONS OF SALE (AVAILABLE AT WWW.CONTECHES.COM/COS) FOR MORE INFORMATION. ® Bioretention Systems ENGINEERED SOLUTIONS NOTHING IN THIS CATALOG SHOULD BE CONSTRUED AS A WARRANTY. APPLICATIONS SUGGESTED HEREIN ARE DESCRIBED ONLY TO HELP READERS MAKE THEIR OWN EVALUATIONS AND DECISIONS, AND ARE NEITHER GUARANTEES NOR WARRANTIES OF SUITABILITY FOR ANY APPLICATION. CONTECH MAKES NO WARRANTY WHATSOEVER, EXPRESS OR IMPLIED, RELATED TO THE APPLICATIONS, MATERIALS, COATINGS, OR PRODUCTS DISCUSSED HEREIN. ALL IMPLIED WARRANTIES OF MERCHANTABILITY AND ALL IMPLIED WARRANTIES OF FITNESS FOR ANY PARTICULAR PURPOSE ARE DISCLAIMED BY CONTECH. SEE CONTECH’S CONDITIONS OF SALE (AVAILABLE AT WWW.CONTECHES.COM/COS) FOR MORE INFORMATION. © 2023 Contech Engineered Solutions LLC, a QUIKRETE Company ALL RIGHTS RESERVED. PRINTED IN THE USA. 39Page 5 of 28 of Page 5 of 36 of 39 6 Note: To avoid underestimating the volume of sediment in the chamber, carefully lower the measuring device to the top of the sediment pile. Finer silty particles at the top of the pile may be more difficult to feel with a measuring stick. These finer particles typically offer less resistance to the end of the rod than larger particles toward the bottom of the pile. CDS Model Diameter Distance from Water Surface to Top of Sediment Pile Sediment Storage Capacity ft m ft m y3 m3 CDS1515 3 0.9 3.0 0.9 0.5 0.4 CDS2015 4 1.2 3.0 0.9 0.9 0.7 CDS2015 5 1.5 3.0 0.9 1.3 1.0 CDS2020 5 1.5 3.5 1.1 1.3 1.0 CDS2025 5 1.5 4.0 1.2 1.3 1.0 CDS3020 6 1.8 4.0 1.2 2.1 1.6 CDS3025 6 1.8 4.0 1.2 2.1 1.6 CDS3030 6 1.8 4.6 1.4 2.1 1.6 CDS3035 6 1.8 5.0 1.5 2.1 1.6 CDS4030 8 2.4 4.6 1.4 5.6 4.3 CDS4040 8 2.4 5.7 1.7 5.6 4.3 CDS4045 8 2.4 6.2 1.9 5.6 4.3 CDS5640 10 3.0 6.3 1.9 8.7 6.7 CDS5653 10 3.0 7.7 2.3 8.7 6.7 CDS5668 10 3.0 9.3 2.8 8.7 6.7 CDS5678 10 3.0 10.3 3.1 8.7 6.7 Table 1: CDS Maintenance Indicators and Sediment Storage Capacities please enlarge text size to 8 point font size or larger 7 CDS Inspection & Maintenance Log CDS Model: Location: Water Floatable Describe Maintenance Date depth to Layer Maintenance Personnel Comments sediment1 Thickness2 Performed —————————————————————————————————————————————————————————— —————————————————————————————————————————————————————————— —————————————————————————————————————————————————————————— —————————————————————————————————————————————————————————— —————————————————————————————————————————————————————————— —————————————————————————————————————————————————————————— —————————————————————————————————————————————————————————— —————————————————————————————————————————————————————————— —————————————————————————————————————————————————————————— —————————————————————————————————————————————————————————— —————————————————————————————————————————————————————————— —————————————————————————————————————————————————————————— —————————————————————————————————————————————————————————— —————————————————————————————————————————————————————————— 1. The water depth to sediment is determined by taking two measurements with a stadia rod: one measurement from the manhole opening to the top of the sediment pile and the other from the manhole opening to the water surface. If the difference between these measurements is less than the values listed in table 1 the system should be cleaned out. Note: to avoid underestimating the volume of sediment in the chamber, the measuring device must be carefully lowered to the top of the sediment pile. 2. For optimum performance, the system should be cleaned out when the floating hydrocarbon layer accumulates to an appreciable thickness. In the event of an oil spill, the system should be cleaned immediately. Page 5 of 30 of 39 PDF 1/23 © 2023 Contech Engineered Solutions LLC, a QUIKRETE Company 9100 Centre Pointe Drive, Suite 400 West Chester, OH 45069 info@conteches.com | 800-338-1122 www.ContechES.com ALL RIGHTS RESERVED. PRINTED IN THE USA. NOTHING IN THIS CATALOG SHOULD BE CONSTRUED AS A WARRANTY. APPLICATIONS SUGGESTED HEREIN ARE DESCRIBED ONLY TO HELP READERS MAKE THEIR OWN EVALUATIONS AND DECISIONS, AND ARE NEITHER GUARANTEES NOR WARRANTIES OF SUITABILITY FOR ANY APPLICATION. CONTECH MAKES NO WARRANTY WHATSOEVER, EXPRESS OR IMPLIED, RELATED TO THE APPLICATIONS, MATERIALS, COATINGS, OR PRODUCTS DISCUSSED HEREIN. ALL IMPLIED WARRANTIES OF MERCHANTABILITY AND ALL IMPLIED WARRANTIES OF FITNESS FOR ANY PARTICULAR PURPOSE ARE DISCLAIMED BY CONTECH. SEE CONTECH’S CONDITIONS OF SALE (AVAILABLE AT WWW.CONTECHES.COM/COS) FOR MORE INFORMATION. ® Bioretention Systems ENGINEERED SOLUTIONS NOTHING IN THIS CATALOG SHOULD BE CONSTRUED AS A WARRANTY. APPLICATIONS SUGGESTED HEREIN ARE DESCRIBED ONLY TO HELP READERS MAKE THEIR OWN EVALUATIONS AND DECISIONS, AND ARE NEITHER GUARANTEES NOR WARRANTIES OF SUITABILITY FOR ANY APPLICATION. CONTECH MAKES NO WARRANTY WHATSOEVER, EXPRESS OR IMPLIED, RELATED TO THE APPLICATIONS, MATERIALS, COATINGS, OR PRODUCTS DISCUSSED HEREIN. ALL IMPLIED WARRANTIES OF MERCHANTABILITY AND ALL IMPLIED WARRANTIES OF FITNESS FOR ANY PARTICULAR PURPOSE ARE DISCLAIMED BY CONTECH. SEE CONTECH’S CONDITIONS OF SALE (AVAILABLE AT WWW.CONTECHES.COM/COS) FOR MORE INFORMATION. © 2023 Contech Engineered Solutions LLC, a QUIKRETE Company ALL RIGHTS RESERVED. PRINTED IN THE USA. 39Page 5 of 28 of Page 5 of 37 of 39 7 CDS Inspection & Maintenance Log CDS Model: Location: Water Floatable Describe Maintenance Date depth to Layer Maintenance Personnel Comments sediment1 Thickness2 Performed —————————————————————————————————————————————————————————— —————————————————————————————————————————————————————————— —————————————————————————————————————————————————————————— —————————————————————————————————————————————————————————— —————————————————————————————————————————————————————————— —————————————————————————————————————————————————————————— —————————————————————————————————————————————————————————— —————————————————————————————————————————————————————————— —————————————————————————————————————————————————————————— —————————————————————————————————————————————————————————— —————————————————————————————————————————————————————————— —————————————————————————————————————————————————————————— —————————————————————————————————————————————————————————— —————————————————————————————————————————————————————————— 1. The water depth to sediment is determined by taking two measurements with a stadia rod: one measurement from the manhole opening to the top of the sediment pile and the other from the manhole opening to the water surface. If the difference between these measurements is less than the values listed in table 1 the system should be cleaned out. Note: to avoid underestimating the volume of sediment in the chamber, the measuring device must be carefully lowered to the top of the sediment pile. 2. For optimum performance, the system should be cleaned out when the floating hydrocarbon layer accumulates to an appreciable thickness. In the event of an oil spill, the system should be cleaned immediately. 1. The water depth to sediment is determined by taking two measurements with a stadia rod: one measurement from the manhole opening to the top of the sediment pile and the other from the manhole opening to the water surface. If the difference between these measurements is less than the values listed in table 1 the system should be cleaned out. Note: to avoid underestimating the volume of sediment in the chamber, the measuring device must be carefully lowered to the top of the sediment pile. 2. For optimum performance, the system should be cleaned out when the floating hydrocarbon layer accumulates to an appreciable thickness. In the event of an oil spill, the system should be cleaned immediately.please enlarge text size to 8 point font size or larger SUPPORT • Drawings and specifications are available at www.ContechES.com. • Site-specific design support is available from our engineers. ©2017 Contech Engineered Solutions LLC, a QUIKRETE Company Contech Engineered Solutions provides site solutions for the civil engineering industry. Contech’s portfolio includes bridges, drainage, sanitary sewer, earth stabilization and stormwater treatment products. For information on other Contech division offerings, visit www.ContechES.com or call 800.338.1122 NOTHING IN THIS CATALOG SHOULD BE CONSTRUED AS A WARRANTY. APPLICATIONS SUGGESTED HEREIN ARE DESCRIBED ONLY TO HELP READERS MAKE THEIR OWN EVALUATIONS AND DECISIONS, AND ARE NEITHER GUARANTEES NOR WARRANTIES OF SUITABILITY FOR ANY APPLICATION. CONTECH MAKES NO WARRANTY WHATSOEVER, EXPRESS OR IMPLIED, RELATED TO THE APPLICATIONS, MATERIALS, COATINGS, OR PRODUCTS DISCUSSED HEREIN. ALL IMPLIED WARRANTIES OF MERCHANTABILITY AND ALL IMPLIED WARRANTIES OF FITNESS FOR ANY PARTICULAR PURPOSE ARE DISCLAIMED BY CONTECH. SEE CONTECH’S CONDITIONS OF SALE (AVAILABLE AT WWW.CONTECHES.COM/COS) FOR MORE INFORMATION. The product(s) described may be protected by one or more of the following US patents: 5,322,629; 5,624,576; 5,707,527; 5,759,415; 5,788,848; 5,985,157; 6,027,639; 6,350,374; 6,406,218; 6,641,720; 6,511,595; 6,649,048; 6,991,114; 6,998,038; 7,186,058; 7,296,692; 7,297,266; related foreign patents or other patents pending. 800-338-1122 www.ContechES.com cds_manual 3/17 PDF ENGINEERED SOLUTIONS Page 5 of 30 of 39 PDF 1/23 © 2023 Contech Engineered Solutions LLC, a QUIKRETE Company 9100 Centre Pointe Drive, Suite 400 West Chester, OH 45069 info@conteches.com | 800-338-1122 www.ContechES.com ALL RIGHTS RESERVED. PRINTED IN THE USA. NOTHING IN THIS CATALOG SHOULD BE CONSTRUED AS A WARRANTY. APPLICATIONS SUGGESTED HEREIN ARE DESCRIBED ONLY TO HELP READERS MAKE THEIR OWN EVALUATIONS AND DECISIONS, AND ARE NEITHER GUARANTEES NOR WARRANTIES OF SUITABILITY FOR ANY APPLICATION. CONTECH MAKES NO WARRANTY WHATSOEVER, EXPRESS OR IMPLIED, RELATED TO THE APPLICATIONS, MATERIALS, COATINGS, OR PRODUCTS DISCUSSED HEREIN. ALL IMPLIED WARRANTIES OF MERCHANTABILITY AND ALL IMPLIED WARRANTIES OF FITNESS FOR ANY PARTICULAR PURPOSE ARE DISCLAIMED BY CONTECH. SEE CONTECH’S CONDITIONS OF SALE (AVAILABLE AT WWW.CONTECHES.COM/COS) FOR MORE INFORMATION. ® Bioretention Systems ENGINEERED SOLUTIONS NOTHING IN THIS CATALOG SHOULD BE CONSTRUED AS A WARRANTY. APPLICATIONS SUGGESTED HEREIN ARE DESCRIBED ONLY TO HELP READERS MAKE THEIR OWN EVALUATIONS AND DECISIONS, AND ARE NEITHER GUARANTEES NOR WARRANTIES OF SUITABILITY FOR ANY APPLICATION. CONTECH MAKES NO WARRANTY WHATSOEVER, EXPRESS OR IMPLIED, RELATED TO THE APPLICATIONS, MATERIALS, COATINGS, OR PRODUCTS DISCUSSED HEREIN. ALL IMPLIED WARRANTIES OF MERCHANTABILITY AND ALL IMPLIED WARRANTIES OF FITNESS FOR ANY PARTICULAR PURPOSE ARE DISCLAIMED BY CONTECH. SEE CONTECH’S CONDITIONS OF SALE (AVAILABLE AT WWW.CONTECHES.COM/COS) FOR MORE INFORMATION. © 2023 Contech Engineered Solutions LLC, a QUIKRETE Company ALL RIGHTS RESERVED. PRINTED IN THE USA. 39Page 5 of 28 of Page 5 of 38 of 39 SUPPORT • Drawings and specifications are available at www.ContechES.com. • Site-specific design support is available from our engineers. ©2017 Contech Engineered Solutions LLC, a QUIKRETE Company Contech Engineered Solutions provides site solutions for the civil engineering industry. Contech’s portfolio includes bridges, drainage, sanitary sewer, earth stabilization and stormwater treatment products. For information on other Contech division offerings, visit www.ContechES.com or call 800.338.1122 NOTHING IN THIS CATALOG SHOULD BE CONSTRUED AS A WARRANTY. APPLICATIONS SUGGESTED HEREIN ARE DESCRIBED ONLY TO HELP READERS MAKE THEIR OWN EVALUATIONS AND DECISIONS, AND ARE NEITHER GUARANTEES NOR WARRANTIES OF SUITABILITY FOR ANY APPLICATION. CONTECH MAKES NO WARRANTY WHATSOEVER, EXPRESS OR IMPLIED, RELATED TO THE APPLICATIONS, MATERIALS, COATINGS, OR PRODUCTS DISCUSSED HEREIN. ALL IMPLIED WARRANTIES OF MERCHANTABILITY AND ALL IMPLIED WARRANTIES OF FITNESS FOR ANY PARTICULAR PURPOSE ARE DISCLAIMED BY CONTECH. SEE CONTECH’S CONDITIONS OF SALE (AVAILABLE AT WWW.CONTECHES.COM/COS) FOR MORE INFORMATION. The product(s) described may be protected by one or more of the following US patents: 5,322,629; 5,624,576; 5,707,527; 5,759,415; 5,788,848; 5,985,157; 6,027,639; 6,350,374; 6,406,218; 6,641,720; 6,511,595; 6,649,048; 6,991,114; 6,998,038; 7,186,058; 7,296,692; 7,297,266; related foreign patents or other patents pending. 800-338-1122 www.ContechES.com cds_manual 3/17 PDF ENGINEERED SOLUTIONS ©2017 Contech Engineered Solutions LLC, a QUIKRETE Company Contech Engineered Solutions provides site solutions for the civil engineering industry. Contech’s portfolio includes bridges, drainage, sanitary sewer, earth stabilization and stormwater treatment products. For information on other Contech division offerings, visit www.ContechES.com or call 800.338.1122 NOTHING IN THIS CATALOG SHOULD BE CONSTRUED AS A WARRANTY. APPLICATIONS SUGGESTED HEREIN ARE DESCRIBED ONLY TO HELP READERS MAKE THEIR OWN EVALUATIONS AND DECISIONS, AND ARE NEITHER GUARANTEES NOR WARRANTIES OF SUITABILITY FOR ANY APPLICATION. CONTECH MAKES NO WARRANTY WHATSOEVER, EXPRESS OR IMPLIED, RELATED TO THE APPLICATIONS, MATERIALS, COATINGS, OR PRODUCTS DISCUSSED HEREIN. ALL IMPLIED WARRANTIES OF MERCHANTABILITY AND ALL IMPLIED WARRANTIES OF FITNESS FOR ANY PARTICULAR PURPOSE ARE DISCLAIMED BY CONTECH. SEE CONTECH’S CONDITIONS OF SALE (AVAILABLE AT WWW.CONTECHES.COM/COS) FOR MORE INFORMATION. The product(s) described may be protected by one or more of the following US patents: 5,322,629; 5,624,576; 5,707,527; 5,759,415; 5,788,848; 5,985,157; 6,027,639; 6,350,374; 6,406,218; 6,641,720; 6,511,595; 6,649,048; 6,991,114; 6,998,038; 7,186,058; 7,296,692; 7,297,266; related foreign patents or other patents pending. please enlarge text size to 8 point font size or larger EXHIBIT C – LEGAL DESCRIPTION 39Page 5 of 39 of PARCEL: 722400-0675 LOT B OF CITY OF RENTON LOT LINE ADJUSTMENT NO. LUA-11-016-LLA RECORDED JUNE 6, 2011 UNDER RECORDING NO. 20110616900016, RECORDS OF KING COUNTY, WASHINGTON. PARCEL: 722400-0676 LOT A OF CITY OF RENTON LOT LINE ADJUSTMENT NO. LUA-11-016-LLA RECORDED JUNE 6, 2011 UNDER RECORDING NO. 20110616900016, RECORDS OF KING COUNTY, WASHINGTON. PARCEL: 759460-0105 LOTS 1-9, BLOCK 8, RENTON FARM PLAT ACCORDING TO THE PLAT THEREOF RECORDED IN VOLUME 10 OF PLATS, PAGE 97, IN KING COUNTY, WASHINGTON; EXCEPT THOSE PORTIONS OF LOTS 1 THROUGH 5 AS CONDEMNED IN KING COUNTY SUPERIOR COURT CASE NO. 94-2-03644-1 FOR STREET PURPOSES. TOGETHER WITH LOTS 1 THROUGH 12, BLOCK 2, SARTORISVILLE, ACCORDING TO THE PLAT THEREOF RECORDED IN VOLUME 8 OF PLATS, PAGE 7, IN KING COUNTY, WASHINGTON; EXCEPT THE WEST 20 FEET THEREOF.