Loading...
HomeMy WebLinkAboutR-432701N M i O lql- LIJ O J 0 z fy CD 2 O O SHEET LIST SHEET NUMBER SHEET TITLE C-001 COVER SHEET C-002 GENERAL NOTES V-001 EXISTING CONDITIONS & TOPOGRAPHY C-101 DEMOLITION & TEMPORARY EROSION & SEDIMENT CONTROL PLAN C-102 HORIZONTAL CONTROL & PAVING PLAN C-103 GRADING & STORM DRAIN PLAN C-103.1 STORM DRAIN PROFILES C-103.2 STORM DRAIN PROFILES C-104 UTILITY PLAN C-301 GRADING ENLARGEMENT SECTION C-501 TEMPORARY EROSION & SEDIMENT CONTROL DETAILS C-502 TEMPORARY EROSION & SEDIMENT CONTROL DETAILS C-503 PAVING DETAILS C-504 PAVING, STRIPING, AND SIGNAGE DETAILS C-505 STORM DRAIN & STORMWATER MANAGEMENT DETAILS C-506 STORM DRAIN & STORMWATER MANAGEMENT DETAILS C-507 STORM DRAIN & STORMWATER MANAGEMENT DETAILS C-508 STORM DRAIN & STORMWATER MANAGEMENT DETAILS C-510 WATER DETAILS C-511 WATER DETAILS L-100 PLANTING PLAN L-101 PLANTING NOTES AND DETAILS L-102 PLANTING NOTES L-200 TREE INVENTORY PLAN L-201 TREE INVENTORY NOTES AND DETAILS L-300 IRRIGATION PLAN L-301 IRRIGATION DETAILS L-302 IRRIGATION NOTES CONDITIONS PER LUA24-000157: 1. THE APPLICANT SHALL SUBMIT A DETAILED LANDSCAPE PLAN THAT IDENTIFIES USE OF VEGETATION TYPES IDENTIFIED IN RMC 4-4-070.G.6 IN THE PERIMETER LANDSCAPING. THE LANDSCAPE PLAN SHALL BE SUBMITTED TO AND APPROVED BY THE CURRENT PLANNING PROJECT MANAGER PRIOR TO CIVIL CONSTRUCTION APPROVAL. 2. THE APPLICANT SHALL SUBMIT A DETAILED LANDSCAPE PLAN IDENTIFYING COMPLIANCE THE REQUIREMENTS FOR PARKING LOT LANDSCAPING, 10-FEET OF ON -SITE LANDSCAPING ADJACENT TO THE ROW, AND LANDSCAPING IN ALL PERVIOUS AREAS OF THE SITE. THE DETAILED LANDSCAPE PLAN SHALL BE SUBMITTED TO AND APPROVED BY THE CURRENT PLANNING PROJECT MANAGER PRIOR TO CIVIL CONSTRUCTION PERMIT APPROVAL. CIVIL CONSTRUCTION PERMIT 3. THE APPLICANT SHALL SUBMIT PLANS FOR THE TRASH AND RECYCLING ENCLOSURE FOR REVIEW AND APPROVAL BY THE CURRENT PLANNING PROJECT MANAGER PRIOR TO CIVIL CONSTRUCTION PERMIT ISSUANCE. IF THE ENCLOSURE IS VISIBLE FROM THE PUBLIC ROW, A HIGHER QUALITY MATERIAL SUCH AS MASONRY, CEDAR, OR ALTERNATIVE APPROVED BY STAFF SHALL BE USED. 4. THE APPLICANT SHALL PROVIDE DETAILS OF THE PROPOSED OFF-STREET (INTERIOR OR EXTERIOR) BICYCLE PARKING FOR AT LEAST 29 SPACES THAT COMPLIES WITH THE BICYCLE PARKING STANDARDS TO BE REVIEWED AND APPROVED BY THE CURRENT PLANNING PROJECT PRIOR TO BUILDING PERMIT ISSUANCE. 53HE APPLICANT SHALL SUBMIT A LIGHTING PLAN BE PROVIDED THAT DEMONSTRATES COMPLIANCE WITH RMC 4-4-075 AND PROVIDES ENOUGH LIGHT FOR SECURITY BUT DOES NOT CREATE EXCESSIVE LIGHT IMPACTS ON NEIGHBORING PROPERTIES. IN ADDITION, THE PARKING AND PEDESTRIAN AREAS SHALL ALSO CONTAIN ADEQUATE LIGHTING TO ENSURE SAFETY AND SECURITY. THE LIGHTING PLAN SHALL INCLUDE DETAIL SHEETS OF ALL EXISTING AND NEW LIGHT FIXTURES ON SITE, FOOTCANDLE ILLUMINATION INFORMATION, AND SHALL BE REVIEWED AND APPROVED BY THE CURRENT PLANNING PROJECT MANAGER PRIOR TO CIVIL CONSTRUCTION PERMIT ISSUANCE. 63HE APPLICANT SHALL SUBMIT PLANS FOR THE TRASH AND RECYCLING ENCLOSURE FOR REVIEW AND APPROVAL BY THE CURRENT PLANNING PROJECT MANAGER PRIOR TO CIVIL CONSTRUCTION PERMIT ISSUANCE. IF THE ENCLOSURE IS VISIBLE FROM THE PUBLIC ROW, A HIGHER QUALITY MATERIAL SUCH AS MASONRY, CEDAR, OR ALTERNATIVE APPROVED BY STAFF SHALL BE USED. 73HE APPLICANT SHALL SUBMIT A TREE ASSESSMENT PREPARED BY A LICENSED ARBORIST THAT DOCUMENTS THE HEALTH OF THE EXISTING TREES IN THE PLANTER STRIP ALONG SW 10TH ST AND INCLUDES A RECOMMENDATION FOR REPLACEMENT TREES TO BE PLANTED WHERE TREES WERE REMOVED OR WHERE UNHEALTHY TREES ARE RECOMMENDED FOR REMOVAL. IF FEASIBLE, THE APPLICANT SHALL UTILIZE A "MEDIUM" OR "LARGE" STATURE SPECIES FROM THE APPROVED STREET TREE LIST AND SPACING GUIDELINES DOCUMENT. ANY RECOMMENDED TREE MAINTENANCE SHOULD BE PERFORMED PRIOR TO CONSTRUCTION PERMIT CLOSE OUT THE TREE ASSESSMENT AND FRONTAGE PLANTING PLAN SHALL BE SUBMITTED WITH THE BUILDING PERMIT APPLICATION FOR REVIEW AND APPROVAL BY THE CURRENT PLANNING PROJECT MANAGER. THE TREE ASSESSMENT AND REVISED DETAILED LANDSCAPE PLAN SHALL BE REVIEWED AND APPROVED BY THE CURRENT PLANNING PROJECT MANAGER PRIOR TO CIVIL CONSTRUCTION PERMIT ISSUANCE. 83HE APPLICANT SHALL SUBMIT A DETAILED PLAN THAT IDENTIFIES THE METHOD VEHICLES WILL BE DELIVERED TO THE SITE INCLUDING INFORMATION REGARDING THE TYPE OF SEMI TRUCK USED, TURNING MOVEMENT ANALYSIS FOR INGRESS AND EGRESS ON THE SITE, AND CIRCULATION OF THE DELIVERY VEHICLES ON AND OFF THE SITE. THE DETAILED PLAN SHALL BE REVIEWED AND APPROVED BY THE CURRENT PLANNING PROJECT MANAGER PRIOR TO ISSUANCE OF THE CIVIL CONSTRUCTION 9. THE APPLICANT SHALL RECORD A PUBLIC ACCESS EASEMENT OVER THE EXISTING SIDEWALK FRONTING THE PROJECT SITE ALONG SW 10TH ST. A DRAFT OF THE EASEMENT SHALL BE REVIEWED AND APPROVED PRIOR TO ISSUANCE OF THE CIVIL CONSTRUCTION PERMIT. THE EASEMENT SHALL BE RECORDED PRIOR TO ISSUANCE OF A CERTIFICATE OF OCCUPANCY. S88°14'37"E 23 S88°14'37"E 2 180.01' F I I I I I ( I o I I F D co o C c c a UL I I o Ln I a (1j � 00 N Cl LO LO w w ol� wl lq- to � z M z z PARCEL 214600-0010 I U) I w I w I 00 Q 00 Q cD w O O It in I I I z I I I WATER MAIN EASEMENT AFN 8410040587 PARKING LOT UPGRADES TESLA 600 SW I OTH STREET RENTON, WA 98057 RECORD MONUMENT IN CASE W/ BRASS NAIL IN CONCRETE W/ PUNCH AT INTERSECTION OF SW 7TH ST. & LIND AVE. SW 71' S89°09'55"E 366.55' SW 7TH STREET S89°09'55"E 383.24' 1.15'S89°09'53"E 337.12' _ S_89°09'55"E 621.7 ' > 317.50' —1 317.51' 8.0a FOUND MON. IN CASE (V 3" BRASS DISC, 0.4- (V BELOW GRADE W/ NO PUNCH L0 (D N N ^ O oo � O C° w 06 d-- 0) LOT 1 LO (DI to PARCEL 214600-0041 (.Y "ram PARCEL I �I W 214600-0030 ^ O O z ;— M N _r N z o I q ICD N89'09'55"W 317.51' I I N LOT 2 w R-47.8' PARCEL 214600-0040 R=47.5' a S1 °13'40"W 0 N1'13'40"E 1s.00 10.88' 3�7.,ZO' 10.47' 317 , 15.00' S89°09'55"E 725.01' 1 TELECOMMUNICATIONS FACILITY EASEMENT AFN 20000913001715 SURVEYED SITE LOT 5 PARCEL 214600-0050 0 m 8 °09'55"E 308. 256.27' I I I I I I I I I I S1 °13'40"W 10.30' 263 5_8' ____ 1Es S%-7 604 �i S��- 2 04 40 2% CONTROL DIAGRAM 0 SCALE: 1 " = 150' w NO. REVISION zo O (D �I 00 d- I N 77°27'04"E 82.37' SURVEYED: 04/01/21 DESIGNED: BB/AT/HD DRAWN: BB/AT/HD CHECKED: CM BY I DATE I AP P R I APPROVED: im AERIAL OBTAINED FROM NEAR MAPS NEIGHBORHOOD DETAIL MAP SCALE: 1" = 200' PARKING, LOT COVERAGE, LANDSCAPE ANALYSIS: TOTAL SQUARE FOOTAGE OF THE SITE: 436,044 SF TOTAL SQUARE FOOTAGE OF EXISTING AREA(S) OF IMPERVIOUS SURFACING: 170,187 SF TOTAL SQUARE FOOTAGE OF EXISTING NATURAL/UNDEVELOPED AREA: 112,485 SF SQUARE FOOTAGE (BY FLOOR AND OVERALL TOTAL) OF EACH INDIVIDUAL BUILDING AND/OR USE: 114,531 SF TOTAL SQUARE FOOTAGE OF THE FOOTPRINTS OF ALL BUILDINGS: 114,531 SF PERCENTAGE OF LOT COVERED BY BUILDINGS OR STRUCTURES: 26.3% TOTAL PAVEMENT SQUARE FOOTAGE, BOTH EXISTING PAVEMENT TO REMAIN PLUS NEW PAVEMENT PROPOSED TO BE INSTALLED: EXISTING PAVEMENT TO REMAIN = 3,841 SF, NEW PAVEMENT PROPOSED TO BE INSTALLED = 203,866 SF SQUARE FOOTAGE OF ANY ON —SITE WETLANDS: N/A PARKING ANALYSIS TO INCLUDE THE TOTAL NUMBER OF PARKING SPACES REQUIRED AND PROVIDED, NUMBER OF COMPACT AND "ADA ACCESSIBLE" SPACES PROVIDED, AND PARKING SPACE DIMENSIONS: 535 REGULAR, 11 ADA, 4 COMPACT SQUARE FOOTAGE OF LANDSCAPING FOR EACH AREA, FOR INTERIOR PARKING LOT LANDSCAPING, AND TOTAL: INTERIOR PARKING LOT LANDSCAPING: 9,187 SF, TOTAL: 30,666 SF ALLOWABLE AND PROPOSED BUILDING HEIGHT: 32' BUILDING SETBACKS REQUIRED BY CODE: 15' FRONT SETBACK (SOUTH) PROPOSED BUILDING SETBACKS: 15' FRONT SETBACK (SOUTH) SCALE: AS SHOWN ONE INCH AT FULL SCALE IF NOT ONE INCH SCALE ACCORDINGLY VERTICAL: NAVD 1988 HORIZONTAL: NAD 1983/1991 DATU M CITY OF RENTON Planning/Building/Public Works Dept. DEVELOPMENT ENGINEERING yqi 05/13/2025 R-432701 IN COMPLIANCE WITH CITY OF RENTON STANDARDS Surface Water Enginering CURRENT PLANNING Ar%�- jfarah 05/05/2025 ILamorganroth -� 05/13/2025 REGIONAL FIRE AUTHORITY eNTo WATER UTILITY APPROVED m� dv4 z cthomas 05/05/2025 O°9 FPEPVSaOP JValdez 05/06/2025 DATE: 600 SW 10TH PARKING LOT FlELDBOOK: 0025 OK: PAGE: COVER SHEET DRAWING N0: C-001 SHEET: OF: 1 28 A, u ti O O O N Q J CO O O i N L.L O V z O U) O Cfl