HomeMy WebLinkAboutR-432723O
N
O )sENECA IAVSW
0 (R.O.W. VAR( S)
w I (PUBLIC AS HAL ROAD)
Uj (CURB WITH V RIES)
O
J
Z
^Q
I..L
2
O
>r
V )
O
I I I I 1 1Al 1 1 1 1 1 1 1 1 1 1 1 1' 1
I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I
128-5811 LILII1
I I �I I IIIII IIIIIIIIII I_�I
� IIil1 III I�I�;I;I; II
I
I LATERAL PIPE SHOWN FOR CLARITY. LATERAL
III I I I PIPE TO BE INSTALLED IN GREEN SPACE 6"
I FROM B.O.C. OR PROPERTY LINE (TYP.)
I (III
1I
I I i1i il�
,I 1
(III 25.15�a��oveeeo eeeeoeoeeo'eooeo 1 ■79 1 I Ie e e o e o e o 0 o e o e e e o e e o e o Q IIII eoeeoeoeaeooe ----_ 300 11 ■34 1
IIIIIIIIII I i 1 1 - I e p e e o o e o e o o e o e e o e o
1 ' I
II;I;I;I;I;Iu EI - - - _ ► II - 12
Q.95 ----- I I
11 (IIIIIIII C6 I I C7 I I (III
II 1;1;111;1 1Y2"30.4 III i1Y2"39.7 II I C8 I I (III t I I I`I I III I I I I 1Y2"42.7
1111111i111� I I I I
I I I I I I I I I II II I I IIIII
IIIII II IIIi i l l Jl 'l l l 'l 'C5, I /I2=•12 6 r 'r
1 Y2" 8. 8 I-W , 1 _III I 111
Illlll (III
IIIIIII�IIIIi I I I I
lllllllil
1111111 11I 26.461 II IIIII
I I I I I
111111111111 , 2.41 III III
''
1111111'11111 I
Illlll IIIII 'Ill I (;III I;II C9
e e e o o e o e o o e o e e o e o e e e e o e e o e e e e l l I;I
�0.96 eoeeoeeoeoeeoeoeeoeeeeoeeoee l Illll 1 ovoeooeoe oeooeoeooeoeeol I 1 �I
I; I;I;III;I;I _ -- -- -- -- -- I I I-- 1 ■34 looeoeeoeo eoeoC=C=_ epee 1 I 1 "
-�
1Y2"2 5111 1 34 1 1 ,IIIII III
I I I I �\ \
I I I
t
II 1 1 (;I�I�I�II
11II II I I111I ® °'- - - -AF i1 - 1 11111111II
i I I I I I11 �� I O- ■- eoe I - -
I I I I I �■7 3 e- oeo F-■ .7 I IIIIIIIIf
I I I I I IIIII III
APPROXIMATE LOCATION OF EXISTING APPROXIMATE LOCATION OF EXISTING 1 1 1 1 1 I1 1
IRRIGATION MAINLINE; ASSUMED 2" SCH 40 PVC IRRIGATION MAINLINE; ASSUMED 2" SCH 40 PVC115.0'
------- `n, FIELD VERIFY LOCATION AND TIE INTO EXISTING FIELD VERIFY LOCATION AND TIE INTO EXISTING
MAINLINE FOR SYSTEM MODIFICATIONS. MAINLINE FOR SYSTEM MODIFICATIONS.
11111111111 I I I
POC, BACKFLOW PREVENTOR, MASTER VALVE, AND FLOW SENSOR SHOWN SCHEMATICALLY. CONTRACTOR TO TAP (IIIIIIIIII
az I I I I
Y 1 1 1 1 1 1 1 1 OFF OF DOMESTIC LINE AND COORDINATE FINAL LOCATION WITH OWNER/ARCHITECT. 1 1 1 i •' i 1'
C (III Poc r 1111
I I I BF
1Y2" 91.74 i i 1 i I RAIN SENSOR AND CONTROLLER SHOWN SCHEMATICALLY. CONTRACTOR TO COORDINATE FINAL LOCATION WITH OWNER/ARCHITECT. 1 I I I I III
I I I I I
I I 1 1 o CONTRACTOR TO PROVIDE 110/120V, SINGLE PHASE POWER TO CONTROLLER. 1 1 1 1 1 I l
I I III
111 11 1 11 111 I CONTRACTOR TO PROVIDE CONNECTION FROM CONTROLLER TO FLOW SENSOR. T I I I l l
1 1 1 1 1 1 1 1 1 1 1 AVOID OVERHEAD OBSTRUCTIONS AND OVERSPRAY ASSOCIATED WITH RAIN SENSOR. IIIII 11
Illlll 11111 I IIIII I
#IIIII IIIII IIIII II
i 1 1 1 1 1 1 1 1 1 MAINLINE AND VALVES SHOWN FOR CLARITY. 1 1 1 1 1 1 1
IIIIIII III1 l 10.521 MAINLINE AND VALVES TO BE INSTALLED IN ( I I I 19-89GREEN SPACE 6" FROM B.O.C. (TYP.) I I I I I II'I'l
11111111111.... .................. ............... . IIIII 1
II I I I I I 3.62 I ( I I I
II;I;I;II;I;I I I I I I I I I I 111 I I I
I• I, I, I I I I I I I ' I I I I I I I I I I I
111111111111 o t I I Illlll- - I I I I I I I I I I I
N I I I I I
1111111I11111 v I,I,J, _ ' j IIIII 111
I I I 2" I 301111951
11111111111 I 11 III �I� I I �� 11 I 11
;I 13,
I; �29.21 ; I I[L
I I 1I 1II 1
, C10
2"
1 .87 1 1 1 1 1 1 1 .88 I I I I 1 1 1 1 1 1 1 r �2" 1 Y2" 34.6
2I I 1 I - -
I I �
C21 I ; ; I ; I FIELD VERIFY LOCATION OF EXISTING 1I 1%" . 36
1 11�111I LATERAL PIPE, TIE INTO EXISTING AND vv
1/2 3 .2 11 T 1. 1, EXTEND TO NEW BUBBLER LOCATIONS SHOWN lull
13.31 111'2„Illlll~
12 1
Z
C 11 1 I I 1 I 1 I I I I I- 1 1 � � � � � • �>
Y2" 218.4 ' I 1 ' I 1 I 1 1 1 I I-- •� 1 1 I 1 1 -- cw� ' -/
I 11�111111 111 0 � � � I _
II; I; I; 1 I 1 I 11 I 1 I l �I I I � I � � � �'• �= i� (w)' i ' ��
131
I1I1 � � I I �-
11111111 3 1 .21 111 � - I �
II I I I I I II I��I ' I
1111111111 I I I I, III I� �� I 1 .� I I� L=� i�w� �
II 1 11 11 11 11 1 1111 1 1 111 5.35 I I FIELD VERIFY LOCATION OF EXISTING
11i1 11 11 11 11 1 11 11 , C11 1 1 1 i I LATERAL PIPE; TIE INTO EXISTING AND
f EXTEND TO NEW BUBBLER LOCATIONS SHOWN
- '
T
I 4!t1111 �I 111,1 ���
2"77
I1I�I'I'liiiii i i i ---�
( I I I I I I I I I I I I I
I IIIIIIIIIIIIIIIIIII I I ,(,III
I Illlll � (IIIIIIIIII I II
I IIIIIIIIIIIIIIIIIII I I I
Ili'i'illi'i' I
PIPE SLEEVES TYP.
I (IIIIIIIIII I I
1111111111111 I I
M
LO
SYMBOL DESCRIPTION QTY PRECIP PSI GPM COST TOTAL N
IIIIIIIIIIIIIIIIIIIII SHRUB AREA FOR DRIP EMITTERS - MEDIUM DENSITY O
I I I I I I I I I I ONE OR MORE DRIP EMITTERS PER PLANT, WITH DRIP TUBING EITHER 71,049 SF 0.45 in/h 25 327 N
IIIIIIIIIIIIIIIIIIIII ABOVE OR BELOW GRADE. 90% OR LESS FOLIAGE COVERAGE OF THE N
I I I I I I I I PLANTED AREA.
SYMBOL MANUFACTURER/MODEL/DESCRIPTION QTY
RAIN BIRD XCZ-1150-LCS
B HIGH FLOW CONTROL ZONE KIT, FOR LARGE COMMERCIAL DRIP ZONES. 11
1-1/21N. PEB GLOBE VALVE WITH SINGLE 1-1/21N. PRESSURE REGULATING
40PS1 QUICK -CHECK BASKET FILTER. FLOW RANGE: 15-62 GPM.
Q RAIN BIRD MDCFCAP 35
DRIPLINE FLUSH VALVE CAP IN COMPRESSION FITTING COUPLER.
RAIN BIRD OPERIND
® DRIP SYSTEM OPERATION INDICATOR, STEM RISES 61N. FOR CLEAR 11
VISIBILITY WHEN DRIP SYSTEM IS CHARGED TO A MINIMUM OF 20PS1.
INCLUDES 161N. OF 1/41N. DISTRIBUTION TUBING WITH CONNECTION
FITTING PRE -INSTALLED.
co
SYMBOL MANUFACTURER/MODEL/DESCRIPTION QTY
RAIN BIRD 7 1 O
O 1-1/21N. BRASS QUICK -COUPLING VALVE, WITH CORROSION -RESISTANT O
STAINLESS STEEL SPRING, METAL COVER, AND 1-PIECE BODY. O
RAIN BIRD PEB 1-1/2"
M 11N., 1-1/21N., 21N., 31N. PLASTIC INDUSTRIAL MASTER VALVES. LOW FLOW 1
OPERATING CAPABILITY, GLOBE CONFIGURATION. N
BF WATTS LF909M1 1-1/2" 1
LEAD FREE REDUCED PRESSURE BACKFLOW PREVENTER.
RAIN BIRD ESPLXME2-LXMMSS
TR 12 STATION TRADITIONALLY -WIRED, COMMERCIAL CONTROLLER. 1 J
INDOOR/OUTDOOR, PLASTIC WALL -MOUNT ENCLOSURE. INSTALL IN
LXMMSS STAINLESS STEEL CABINET.
RAIN BIRD WR2-RFC 1
WIRELESS RAIN AND FREEZE SENSOR COMBO, INCLUDES 1 RECEIVER
AND 1 RAIN/FREEZE SENSOR TRANSMITTER.
RAIN BIRD UFS-100
FS 11N. ULTRASONIC FLOW SENSORS, WITH GLASS FILLED NYLON BODY. 1
OPERATING RANGE .3 GPM-50 GPM. SIZE FOR FLOW NOT ACCORDING TO
PIPE SIZE.
POC
POINT OF CONNECTION 1 1/2" 1
IRRIGATION LATERAL LINE: PVC SCHEDULE 40 3,111 L.F.
IRRIGATION MAINLINE: PVC SCHEDULE 40 2,356 L.F. O
PIPE SLEEVE: PVC SCHEDULE 40 1,707 L.F. O
Valve Callout
N
# Valve Number n/
#'# Valve Flow
VALVE SCHEDULE
NUMBER
MODEL
SIZE
TYPE
GPM
WIRE
PSI
PSI @ POC
PRECIP
C1
RAIN BIRD XCZ-150-LCS
1-1/2"
SHRUB AREA FOR DRIP EMITTERS - MEDIUM DENSITY
28.44
1,048
35.0
57.6
0.45 in/h
C2
RAIN BIRD XCZ-150-LCS
1-1/2"
SHRUB AREA FOR DRIP EMITTERS - MEDIUM DENSITY
31.21
1,065
31.4
55.4
0.45 in/h
C3
RAIN BIRD XCZ-150-LCS
1-1/2"
SHRUB AREA FOR DRIP EMITTERS - MEDIUM DENSITY
9.74
1,172
34.0
50.8
0.45 in/h
C4
RAIN BIRD XCZ-150-LCS
1-1/2"
SHRUB AREA FOR DRIP EMITTERS - MEDIUM DENSITY
26.46
1,053
33.3
53.7
0.45 in/h
C5
RAIN BIRD XCZ-150-LCS
1-1/2"
SHRUB AREA FOR DRIP EMITTERS - MEDIUM DENSITY
8.38
954.6
32.8
48.9
0.45 in/h
C6
RAIN BIRD XCZ-150-LCS
1-1/2"
SHRUB AREA FOR DRIP EMITTERS - MEDIUM DENSITY
30.44
874.5
34.8
56.4
0.45 in/h
C7
RAIN BIRD XCZ-150-LCS
1-1/2"
SHRUB AREA FOR DRIP EMITTERS - MEDIUM DENSITY
39.71
652.6
33.2
56.5
0.45 in/h
C8
RAIN BIRD XCZ-150-LCS
1-1/2"
SHRUB AREA FOR DRIP EMITTERS - MEDIUM DENSITY
42.72
435.3
34.4
53.6
0.45 in/h
C9
RAIN BIRD XCZ-150-LCS
1-1/2"
SHRUB AREA FOR DRIP EMITTERS - MEDIUM DENSITY
11.46
203.2
44.3
60.3
0.45 in/h
C10
RAIN BIRD XCZ-150-LCS
1-1/2"
SHRUB AREA FOR DRIP EMITTERS - MEDIUM DENSITY
34.63
184.6
33.8
49.9
0.45 in/h
C 1 1
RAIN BIRD XCZ-150-LCS
1-1/2"
SHRUB AREA FOR DRIP EMITTERS - MEDIUM DENSITY
27.09
857.9
32.6
54.5
0.45 in/h
Common Wire
2,356
CRITICAL ANALYSIS
Generated:
2024-09-24 08:59
P.O.C. NUMBER: 01
Water Source Information:
FLOW AVAILABLE
Point of Connection Size:
1 1/2"
Flow Available
46.59 GPM
PRESSURE AVAILABLE
Static Pressure at POC:
80 PSI
Pressure Available:
80 PSI
DESIGN ANALYSIS
Maximum Station Flow:
42.72 GPM
Flow Available at POC:
46.59 GPM
Residual Flow Available:
3.87 GPM
Design Pressure:
25 PSI
Friction Loss:
13.0 PSI
Fittings Loss:
1.3 PSI
Elevation Loss:
0 PSI
Loss through Valve:
5 PSI
Pressure Req. at Critical Station:
44.3 PSI
Loss for Fittings:
0.02 PSI
Loss for Main Line:
0.2 PSI
Loss for POC to Valve Elevation:
0 PSI
Loss for Backflow:
11.9 PSI
Loss for Master Valve:
3.9 PSI
Critical Station Pressure at POC:
60.2 PSI
Pressure Available:
80 PSI
Residual Pressure Available:
19.8 PSI
I ' w)
1 CCP SUBMITTAL #1 D5/10/22 SURVEYED:04/01/21 SCALE: VERTICAL: NAVD 1988
w
HORIZONTAL: NAD 1983/1991
DESICNED:AD/CH/NW AS SHOWN
FIELD VERIFY LOCATION OF EXISTING DRAWN: AD/CH/NW ONE INCH DATUM
13.59 LATERAL PIPE; TIE INTO EXISTING AND CHECKED: CM AT FULL SCALE
EXTEND TO NEW BUBBLER LOCATIONS SHOWN NOT ONE INCH
N 0. REVISION BY DATE AP P R APPROVED: SC
ALE ACCORDINGLY
GRAPHIC SCALE IN FEET
0 20 40 80
CITY OF
R
RENTON
VASOF
Planning/Building/Public Works Dept.
OF WAS&
a\PN GjO ��''>,
�-
(0
U�\
�Q O 22011619 ��Q �G)
4gNOS C APB P
O
IN COMPLIANCE WITH CITY OF RENTON STANDARDS J
cD
CURRENT PLANNING Z
DEVELOPMENT ENGINEERING
amorganroth
05/13/2025 yqi 05/13/2025
Q
2
DATE:
600 SW 10TH PARKING LOT 0OOK: 024 O
r
FlELDBOK:
PAGE:
IRRIGATION PLAN DRAWING NO: U1
L-300 O
SHEET: 25 OF: 27 O