Loading...
HomeMy WebLinkAboutR-432723O N O )sENECA IAVSW 0 (R.O.W. VAR( S) w I (PUBLIC AS HAL ROAD) Uj (CURB WITH V RIES) O J Z ^Q I..L 2 O >r V ) O I I I I 1 1Al 1 1 1 1 1 1 1 1 1 1 1 1' 1 I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I 128-5811 LILII1 I I �I I IIIII IIIIIIIIII I_�I � IIil1 III I�I�;I;I; II I I LATERAL PIPE SHOWN FOR CLARITY. LATERAL III I I I PIPE TO BE INSTALLED IN GREEN SPACE 6" I FROM B.O.C. OR PROPERTY LINE (TYP.) I (III 1I I I i1i il� ,I 1 (III 25.15�a��oveeeo eeeeoeoeeo'eooeo 1 ■79 1 I Ie e e o e o e o 0 o e o e e e o e e o e o Q IIII eoeeoeoeaeooe ----_ 300 11 ■34 1 IIIIIIIIII I i 1 1 - I e p e e o o e o e o o e o e e o e o 1 ' I II;I;I;I;I;Iu EI - - - _ ► II - 12 Q.95 ----- I I 11 (IIIIIIII C6 I I C7 I I (III II 1;1;111;1 1Y2"30.4 III i1Y2"39.7 II I C8 I I (III t I I I`I I III I I I I 1Y2"42.7 1111111i111� I I I I I I I I I I I I I II II I I IIIII IIIII II IIIi i l l Jl 'l l l 'l 'C5, I /I2=•12 6 r 'r 1 Y2" 8. 8 I-W , 1 _III I 111 Illlll (III IIIIIII�IIIIi I I I I lllllllil 1111111 11I 26.461 II IIIII I I I I I 111111111111 , 2.41 III III '' 1111111'11111 I Illlll IIIII 'Ill I (;III I;II C9 e e e o o e o e o o e o e e o e o e e e e o e e o e e e e l l I;I �0.96 eoeeoeeoeoeeoeoeeoeeeeoeeoee l Illll 1 ovoeooeoe oeooeoeooeoeeol I 1 �I I; I;I;III;I;I _ -- -- -- -- -- I I I-- 1 ■34 looeoeeoeo eoeoC=C=_ epee 1 I 1 " -� 1Y2"2 5111 1 34 1 1 ,IIIII III I I I I �\ \ I I I t II 1 1 (;I�I�I�II 11II II I I111I ® °'- - - -AF i1 - 1 11111111II i I I I I I11 �� I O- ■- eoe I - - I I I I I �■7 3 e- oeo F-■ .7 I IIIIIIIIf I I I I I IIIII III APPROXIMATE LOCATION OF EXISTING APPROXIMATE LOCATION OF EXISTING 1 1 1 1 1 I1 1 IRRIGATION MAINLINE; ASSUMED 2" SCH 40 PVC IRRIGATION MAINLINE; ASSUMED 2" SCH 40 PVC115.0' ------- `n, FIELD VERIFY LOCATION AND TIE INTO EXISTING FIELD VERIFY LOCATION AND TIE INTO EXISTING MAINLINE FOR SYSTEM MODIFICATIONS. MAINLINE FOR SYSTEM MODIFICATIONS. 11111111111 I I I POC, BACKFLOW PREVENTOR, MASTER VALVE, AND FLOW SENSOR SHOWN SCHEMATICALLY. CONTRACTOR TO TAP (IIIIIIIIII az I I I I Y 1 1 1 1 1 1 1 1 OFF OF DOMESTIC LINE AND COORDINATE FINAL LOCATION WITH OWNER/ARCHITECT. 1 1 1 i •' i 1' C (III Poc r 1111 I I I BF 1Y2" 91.74 i i 1 i I RAIN SENSOR AND CONTROLLER SHOWN SCHEMATICALLY. CONTRACTOR TO COORDINATE FINAL LOCATION WITH OWNER/ARCHITECT. 1 I I I I III I I I I I I I 1 1 o CONTRACTOR TO PROVIDE 110/120V, SINGLE PHASE POWER TO CONTROLLER. 1 1 1 1 1 I l I I III 111 11 1 11 111 I CONTRACTOR TO PROVIDE CONNECTION FROM CONTROLLER TO FLOW SENSOR. T I I I l l 1 1 1 1 1 1 1 1 1 1 1 AVOID OVERHEAD OBSTRUCTIONS AND OVERSPRAY ASSOCIATED WITH RAIN SENSOR. IIIII 11 Illlll 11111 I IIIII I #IIIII IIIII IIIII II i 1 1 1 1 1 1 1 1 1 MAINLINE AND VALVES SHOWN FOR CLARITY. 1 1 1 1 1 1 1 IIIIIII III1 l 10.521 MAINLINE AND VALVES TO BE INSTALLED IN ( I I I 19-89GREEN SPACE 6" FROM B.O.C. (TYP.) I I I I I II'I'l 11111111111.... .................. ............... . IIIII 1 II I I I I I 3.62 I ( I I I II;I;I;II;I;I I I I I I I I I I 111 I I I I• I, I, I I I I I I I ' I I I I I I I I I I I 111111111111 o t I I Illlll- - I I I I I I I I I I I N I I I I I 1111111I11111 v I,I,J, _ ' j IIIII 111 I I I 2" I 301111951 11111111111 I 11 III �I� I I �� 11 I 11 ;I 13, I; �29.21 ; I I[L I I 1I 1II 1 , C10 2" 1 .87 1 1 1 1 1 1 1 .88 I I I I 1 1 1 1 1 1 1 r �2" 1 Y2" 34.6 2I I 1 I - - I I � C21 I ; ; I ; I FIELD VERIFY LOCATION OF EXISTING 1I 1%" . 36 1 11�111I LATERAL PIPE, TIE INTO EXISTING AND vv 1/2 3 .2 11 T 1. 1, EXTEND TO NEW BUBBLER LOCATIONS SHOWN lull 13.31 111'2„Illlll~ 12 1 Z C 11 1 I I 1 I 1 I I I I I- 1 1 � � � � � • �> Y2" 218.4 ' I 1 ' I 1 I 1 1 1 I I-- •� 1 1 I 1 1 -- cw� ' -/ I 11�111111 111 0 � � � I _ II; I; I; 1 I 1 I 11 I 1 I l �I I I � I � � � �'• �= i� (w)' i ' �� 131 I1I1 � � I I �- 11111111 3 1 .21 111 � - I � II I I I I I II I��I ' I 1111111111 I I I I, III I� �� I 1 .� I I� L=� i�w� � II 1 11 11 11 11 1 1111 1 1 111 5.35 I I FIELD VERIFY LOCATION OF EXISTING 11i1 11 11 11 11 1 11 11 , C11 1 1 1 i I LATERAL PIPE; TIE INTO EXISTING AND f EXTEND TO NEW BUBBLER LOCATIONS SHOWN - ' T I 4!t1111 �I 111,1 ��� 2"77 I1I�I'I'liiiii i i i ---� ( I I I I I I I I I I I I I I IIIIIIIIIIIIIIIIIII I I ,(,III I Illlll � (IIIIIIIIII I II I IIIIIIIIIIIIIIIIIII I I I Ili'i'illi'i' I PIPE SLEEVES TYP. I (IIIIIIIIII I I 1111111111111 I I M LO SYMBOL DESCRIPTION QTY PRECIP PSI GPM COST TOTAL N IIIIIIIIIIIIIIIIIIIII SHRUB AREA FOR DRIP EMITTERS - MEDIUM DENSITY O I I I I I I I I I I ONE OR MORE DRIP EMITTERS PER PLANT, WITH DRIP TUBING EITHER 71,049 SF 0.45 in/h 25 327 N IIIIIIIIIIIIIIIIIIIII ABOVE OR BELOW GRADE. 90% OR LESS FOLIAGE COVERAGE OF THE N I I I I I I I I PLANTED AREA. SYMBOL MANUFACTURER/MODEL/DESCRIPTION QTY RAIN BIRD XCZ-1150-LCS B HIGH FLOW CONTROL ZONE KIT, FOR LARGE COMMERCIAL DRIP ZONES. 11 1-1/21N. PEB GLOBE VALVE WITH SINGLE 1-1/21N. PRESSURE REGULATING 40PS1 QUICK -CHECK BASKET FILTER. FLOW RANGE: 15-62 GPM. Q RAIN BIRD MDCFCAP 35 DRIPLINE FLUSH VALVE CAP IN COMPRESSION FITTING COUPLER. RAIN BIRD OPERIND ® DRIP SYSTEM OPERATION INDICATOR, STEM RISES 61N. FOR CLEAR 11 VISIBILITY WHEN DRIP SYSTEM IS CHARGED TO A MINIMUM OF 20PS1. INCLUDES 161N. OF 1/41N. DISTRIBUTION TUBING WITH CONNECTION FITTING PRE -INSTALLED. co SYMBOL MANUFACTURER/MODEL/DESCRIPTION QTY RAIN BIRD 7 1 O O 1-1/21N. BRASS QUICK -COUPLING VALVE, WITH CORROSION -RESISTANT O STAINLESS STEEL SPRING, METAL COVER, AND 1-PIECE BODY. O RAIN BIRD PEB 1-1/2" M 11N., 1-1/21N., 21N., 31N. PLASTIC INDUSTRIAL MASTER VALVES. LOW FLOW 1 OPERATING CAPABILITY, GLOBE CONFIGURATION. N BF WATTS LF909M1 1-1/2" 1 LEAD FREE REDUCED PRESSURE BACKFLOW PREVENTER. RAIN BIRD ESPLXME2-LXMMSS TR 12 STATION TRADITIONALLY -WIRED, COMMERCIAL CONTROLLER. 1 J INDOOR/OUTDOOR, PLASTIC WALL -MOUNT ENCLOSURE. INSTALL IN LXMMSS STAINLESS STEEL CABINET. RAIN BIRD WR2-RFC 1 WIRELESS RAIN AND FREEZE SENSOR COMBO, INCLUDES 1 RECEIVER AND 1 RAIN/FREEZE SENSOR TRANSMITTER. RAIN BIRD UFS-100 FS 11N. ULTRASONIC FLOW SENSORS, WITH GLASS FILLED NYLON BODY. 1 OPERATING RANGE .3 GPM-50 GPM. SIZE FOR FLOW NOT ACCORDING TO PIPE SIZE. POC POINT OF CONNECTION 1 1/2" 1 IRRIGATION LATERAL LINE: PVC SCHEDULE 40 3,111 L.F. IRRIGATION MAINLINE: PVC SCHEDULE 40 2,356 L.F. O PIPE SLEEVE: PVC SCHEDULE 40 1,707 L.F. O Valve Callout N # Valve Number n/ #'# Valve Flow VALVE SCHEDULE NUMBER MODEL SIZE TYPE GPM WIRE PSI PSI @ POC PRECIP C1 RAIN BIRD XCZ-150-LCS 1-1/2" SHRUB AREA FOR DRIP EMITTERS - MEDIUM DENSITY 28.44 1,048 35.0 57.6 0.45 in/h C2 RAIN BIRD XCZ-150-LCS 1-1/2" SHRUB AREA FOR DRIP EMITTERS - MEDIUM DENSITY 31.21 1,065 31.4 55.4 0.45 in/h C3 RAIN BIRD XCZ-150-LCS 1-1/2" SHRUB AREA FOR DRIP EMITTERS - MEDIUM DENSITY 9.74 1,172 34.0 50.8 0.45 in/h C4 RAIN BIRD XCZ-150-LCS 1-1/2" SHRUB AREA FOR DRIP EMITTERS - MEDIUM DENSITY 26.46 1,053 33.3 53.7 0.45 in/h C5 RAIN BIRD XCZ-150-LCS 1-1/2" SHRUB AREA FOR DRIP EMITTERS - MEDIUM DENSITY 8.38 954.6 32.8 48.9 0.45 in/h C6 RAIN BIRD XCZ-150-LCS 1-1/2" SHRUB AREA FOR DRIP EMITTERS - MEDIUM DENSITY 30.44 874.5 34.8 56.4 0.45 in/h C7 RAIN BIRD XCZ-150-LCS 1-1/2" SHRUB AREA FOR DRIP EMITTERS - MEDIUM DENSITY 39.71 652.6 33.2 56.5 0.45 in/h C8 RAIN BIRD XCZ-150-LCS 1-1/2" SHRUB AREA FOR DRIP EMITTERS - MEDIUM DENSITY 42.72 435.3 34.4 53.6 0.45 in/h C9 RAIN BIRD XCZ-150-LCS 1-1/2" SHRUB AREA FOR DRIP EMITTERS - MEDIUM DENSITY 11.46 203.2 44.3 60.3 0.45 in/h C10 RAIN BIRD XCZ-150-LCS 1-1/2" SHRUB AREA FOR DRIP EMITTERS - MEDIUM DENSITY 34.63 184.6 33.8 49.9 0.45 in/h C 1 1 RAIN BIRD XCZ-150-LCS 1-1/2" SHRUB AREA FOR DRIP EMITTERS - MEDIUM DENSITY 27.09 857.9 32.6 54.5 0.45 in/h Common Wire 2,356 CRITICAL ANALYSIS Generated: 2024-09-24 08:59 P.O.C. NUMBER: 01 Water Source Information: FLOW AVAILABLE Point of Connection Size: 1 1/2" Flow Available 46.59 GPM PRESSURE AVAILABLE Static Pressure at POC: 80 PSI Pressure Available: 80 PSI DESIGN ANALYSIS Maximum Station Flow: 42.72 GPM Flow Available at POC: 46.59 GPM Residual Flow Available: 3.87 GPM Design Pressure: 25 PSI Friction Loss: 13.0 PSI Fittings Loss: 1.3 PSI Elevation Loss: 0 PSI Loss through Valve: 5 PSI Pressure Req. at Critical Station: 44.3 PSI Loss for Fittings: 0.02 PSI Loss for Main Line: 0.2 PSI Loss for POC to Valve Elevation: 0 PSI Loss for Backflow: 11.9 PSI Loss for Master Valve: 3.9 PSI Critical Station Pressure at POC: 60.2 PSI Pressure Available: 80 PSI Residual Pressure Available: 19.8 PSI I ' w) 1 CCP SUBMITTAL #1 D5/10/22 SURVEYED:04/01/21 SCALE: VERTICAL: NAVD 1988 w HORIZONTAL: NAD 1983/1991 DESICNED:AD/CH/NW AS SHOWN FIELD VERIFY LOCATION OF EXISTING DRAWN: AD/CH/NW ONE INCH DATUM 13.59 LATERAL PIPE; TIE INTO EXISTING AND CHECKED: CM AT FULL SCALE EXTEND TO NEW BUBBLER LOCATIONS SHOWN NOT ONE INCH N 0. REVISION BY DATE AP P R APPROVED: SC ALE ACCORDINGLY GRAPHIC SCALE IN FEET 0 20 40 80 CITY OF R RENTON VASOF Planning/Building/Public Works Dept. OF WAS& a\PN GjO ��''>, �- (0 U�\ �Q O 22011619 ��Q �G) 4gNOS C APB P O IN COMPLIANCE WITH CITY OF RENTON STANDARDS J cD CURRENT PLANNING Z DEVELOPMENT ENGINEERING amorganroth 05/13/2025 yqi 05/13/2025 Q 2 DATE: 600 SW 10TH PARKING LOT 0OOK: 024 O r FlELDBOK: PAGE: IRRIGATION PLAN DRAWING NO: U1 L-300 O SHEET: 25 OF: 27 O