HomeMy WebLinkAboutR-4327240
N
N
O
i
W
NOTES
O
1. FOR WIRE SIZES NO. 14, 12, AND 10, ALL CONNECTIONS IN VALVE BOXES ONLY.
2. INSTALL SPEARS DS-100 DRI-SPLICE CONNECTORS WITH DS-300 SEALANT.
�J
v
SLIP BASE SOCKET OVER END OF
Z
STEP 1
WIRES
i
STRIP WIRES APPROX. 1" FROM ENDS -
r/
TWIST ENDS TOGETHER
Q
STEP 2 ---- APPLY SEALER TO OUTSIDE OF SEALING
PLUG - FILL CAVITY WITH SEALER
PUT CRIMP SLEEVE OVER WIRE ENDS -
CRIMP SLEEVE AND CUT OFF EXCESS WIRE
O
PULL BASE SOCKET OVER WIRE END
/
STEP 3� AS FAR AS POSSIBLE
PUSH SEALING PLUG INTO BASE SOCKET
STEP 4 PUSH WIRES TO END OF BASE SOCKET TO
O
ASSURE COMPLETE SEALING OF CONNECTION
C)
co
DRI-SPLICE TYPE WIRE CONNECTOR
1 IRRIGATION WIRE CONNECTION
SCALE: N.T.S.
PERMANENTLY NOTCH OR
OTHERWISE MARK
HARDSCAPE WHERE SLEEVE
OCCURS HARDSCAPE, TYPICAL
FINISHED 12" MIN.
GRADE
24" MIN. FOR ado
LATERALS
30" MIN. FOR
MAINLINES
KA
SCH. 40 PVC J BACKFILL WITHIN 3" OF SLEEVE SHALL BE
PIPE SLEEVE, FREE OF ROCKS AND STONES LARGER
SIZE NOTED ON THAN 1/4" DIA. IF ROCK CANNOT BE
PLANS REMOVED FROM EXCAVATED SOIL,
PROVIDE CLEAN SAND BEDDING.
1 MAINLINE AND LATERAL PIPE SLEEVING
SCALE: N.T.S.
NOTES:
1. ALL WIRES TO BE INSTALLED PER LOCAL CODE. TAPE AND BUNDLE
WIRES EVERY 7'. PROVIDE EXPANSION COIL AT EACH WIRE
CONNECTION IN VALVE BOX (WRAP AROUND 1/2" O PIPE 15 TIMES).
2. COMPACT SOIL AROUND VALVE BOX TO SAME DENSITY AS ADJACENT
UNDISTURBED SOIL.
3. ALL THREADED PVC JOINTS SHALL BE WRAPPED WITH TEFLON TAPE.
SCH 80 FEMALE ADAPTER
REINFORCED PLASTIC AND NIPPLE
ACCESS BOX W/ SCH 80 PVC THREADED
COVER UNION AND FITTINGS, TYP.
Y2" REVEAL SURFACE MULCH PER
PLANS
1— WIRE CONNECTORS
BRASS BALL VALVE
/ BRICK FOR FOOTING,
ONE AT EACH CORNER
IT CONTROL/
COMMON WIRES
PVC LATERAL
ELECTRIC REMOTE CONTROL VALVE
(OR DRIP ZONE CONTROL KIT), SIZE
AND MODEL AS NOTED ON PLANS
Ki
12" DEEP (3/4" 0) GRAVEL SUMP
ELECTRIC REMOTE CONTROL VALVE
SCALE: N.T.S.
X
SCH. 80 PVC
MAINLINE FITTING
�l
NOTES:
1. SELECT BACKFILL SHALL BE SAND OR SOIL FREE OF ROCKS
AND STONES LARGER THAN 1/4" DIA.
2. BACKFILL MATERIAL SHALL BE WATERED IN AND
COMPACTED TO DENSITY OF ADJACENT UNDISTURBED SOIL.
-FINISHED GRADE
DETECTABLE MARKING TAPE
1
EXCAVATED SOIL,
12" MIN.
REPLACED AND
PVC LATERAL/
-
COMPACTED
DRIP SYSTEM
3" MIN.
I —
SELECT BACKFILL
HEADER PIPE
ALL
LATERAL PIPE
SIDES
FINISHED GRADE
8��
,,��j
DETECTABLE MAINLINE
MARKING TAPE
18.,
,x
EXCAVATED SOIL,
PVC MAINLINES
MIN.
/j/��,
REPLACED AND
AND LOW
COMPACTED
VOLTAGE
SAND BEDDING
COMMON /
CONTROL
CONTROL WIRES
WIRES
MIN
MAINLINE PIPE
I I I I I-
3"MIN. -
SIDES AND
TOP OF PIPE
PIPE TRENCHING AND BACKFILL - MAINLINE,
LATERALS, AND MARKING TAPE
SCALE: N.T.S.
- II
LOOP, BUNDLE, AND
LABEL SPARE WIRES
THAT ARE TO CONTINUE,
AS OCCURS
1/2" WIRE CLOTH GOPHER
PROTECTION SCREEN,
WRAP 6" UP SIDES
(2) 6x2x16 CONCRETE
BLOCK CAPS, ONE ON
EACH SIDE OF BOX
L41
�16
J BOX
RECTANGULAR VALVE
BOX AND COVER; HEAD
BRAND "J BOX" ON LID
WITH 2" HIGH LETTERS
1/2" REVEAL
— FINISHED GRADE
I�
SPARE WIRES THAT
ARE TO TERMINATE
AT THIS BOX: COIL 30"
LENGTH AND I.D. TAG
WIRES TO
CONTROLLER
PVC MAINLINE, SEE
PLAN FOR DETAILS
IRRIGATION WIRING JUNCTION BOX
SCALE: N.T.S.
TREE BUBBLER
SCALE: N.T.S.
OBUBBLER PER LEGEND - 2 PER TREE
O2 MULCH
0 FINISH GRADE/TOP OF MULCH
0 UV RADIATION RESISTANT 1/2-INCH PVC
SCH 80 NIPPLE (LENGTH AS REQUIRED)
0 1/2-INCH FEMALE NPT x 0.490-INCH BARB
ELBOW
O6 SWING PIPE, 12-INCH LENGTH
07 PVC LATERAL PIPE
Og 1/2-INCH MALE NPT x .490-INCH BARB
ELBOW
O9 SCH 40 TEE OR ELL
10 EDGE OF ROOTBALL
11 PVC LATERAL LINE - 3/4"
t
L
c
L
c
L
0
t"J
1 CCP SUBMITTAL #1 05/10/21 SURVEYED:
04/01 /21
DESIGNED:
AD/CH/NW
DRAWN: AD/CH/NW
w CHECKED: CM
NO. REVISION BY DATE APPR APPROVED:
Ld
SUBSURFACE DRIPLINE CONNECTION
SCALE: N.T.S.
FLUSH VALVE
SCALE: N.T.S.
DRIPLINE LAYOUT
SCALE: N.T.S.
SCALE:
AS SHOWN
ONE INCH
AT FULL SCALE
IF NOT ONE INCH
SCALE ACCORDINGLY
VERTICAL: NAVD 1988
HORIZONTAL: NAD 1983/1991
DATU M
10 TOP OF MULCH
O2 FINISH GRADE
O3 DRIP LINE PER PLAN
40 INSERT TEE OR ELBOW
O5
SCH. 80 PVC NIPPLE (LINE
SIZE)
OSCH.
40 PVC TEE (SST)
OSCH.
40 PVC SUPPLY
HEADER (SIZE PER PLAN)
10" ROUND PLASTIC VALVE BOX
OWITH LOCKABLE LID, "CARSON" OR
APPROVED EQUAL
FINISH GRADE - TOP OF VALVE BOX TO
O2 BE 2" ABOVE FINISH GRADE IN
PLANTER AREAS
O3 DRIP EXHAUST HEADER
OBALL VALVE, LINE SIZE
3' COILED LENGTH OF LINE
OSIZE FLEX HOSE. SOLVENT
WELD TO VALVE
O6 RED BRICK TYPICAL, 3 REQUIRED
07 6" DEEP LAYER OF PEA GRAVEL
11) FLUSH VALVE
OSCH. 40 PVC EXHAUST HEADER
03 SCH. 40 PVC TEE OR ELL
OCOMPRESSION ADAPTER
05 DRIP LINE
06 AIR RELIEF VALVE AT HIGH POINT OF
SYSTEM (WHEN INDICATED ON PLANS)
07 SCH. 40 PVC SUPPLY HEADER
08 CONTROL VALVE
Og TREE ROOT BALL (WHERE OCCURS IN
DRIP AREA)
10 RAINBIRD PC-07 EMITTERS (3) OR
EQUAL, WITH DIFFUSER CAPS,
INSERTED IN DRIP LINE AND
GENERALLY SPACED EVENLY AROUND
TREE NEAR EDGES OF ROOT BALL
(WHERE OCCURS)
NOTE: SET DRIP LINES 3"-6" AWAY
FROM HARDSCAPE
%+ 0CITY OF
RENTON
Planning/Building/Public Works Dept.
C'7
LO
N
0
0
N
N
All
r
N
Q
J
OF WASy1
C,\pN G40 �C�'J,
Q
co ad 12
O H
��Q O 22011619 1�_*Q
ZgNOSCAPI(--P
O
IN COMPLIANCE WITH CITY OF RENTON STANDARDS J
CURRENT PLANNING � Z
amorganroth DEVELOPMENT ENGINEERING �'
05/13/2025 yqi 05/13/2025
Q
DATE:
600 SW 10TH PARKING LOT FIELDBOOK: 0024
OK:
PAGE:
IRRIGATION DETAILS DRAWN NO: 0
SHEET: 26 OF: 27 /O
t3.J