HomeMy WebLinkAboutW-432703N N i i r L0 I U 1 C-510 MATERIALS OA TEE OB PIPE OC VALVE OD VALVE BOX OE COUPLING OF TUBING OG BEND OH METER SETTER 01 METER SPREADER O WATER METER OK METER BOX OL COUPLER OM GRAVEL z IN UNIMPROVED ROW } INSTALL METER BOX AT PROPERTY LINE WITH o . 12" COPPER TAILPIECE z�n Z CITY i PRIVATE PIPINGI PIPING w o I wI I 1 1/2" SERVICE 2" SERVICE 2" TAPPED REDUCING TEE (MJxFIPT) 2" TAPPED REDUCING TEE (MJxFIPT) 2" BRASS NIPPLE (MIPT), 4" LENGTH 2" BRASS NIPPLE (MIPT), 4" LENGTH 2" GATE VALVE (FIPT) WITH SQUARE OPERATING 2" GATE VALVE (FIPT) WITH SQUARE OPERATING NUT AND EXTENSION PER STD PLAN 330.7 NUT AND EXTENSION PER STD PLAN 330.7 VALVE BOX AND LID PER STD PLAN 330.7 VALVE BOX AND LID PER STD PLAN 330.7 2" x 1 %" BRASS COUPLING (MIPT x PACK JOINT), 2" BRASS COUPLING (MIPT x PACK JOINT), FORD FORD C44-76-Q-NL OR EQUAL C84-77-Q-NL OR EQUAL 1 %2" TYPE "K" SOFT COPPER TUBING 2" TYPE "K" SOFT COPPER TUBING 1 %2" 90° BRASS BEND (PACK JOINT x PACK JOINT OR 2" 90° BRASS BEND (PACK JOINT x PACK JOINT OR PACK JOINT x FIPT), FORD L44-66-Q-NL OR PACK JOINT x FIPT), FORD L44-77-Q-NL OR L41-66-Q-NL OR EQUAL L41-77-Q-NL OR EQUAL 1 Y2" VERTICAL METER SETTER WITH BYPASS, 2" VERTICAL METER SETTER WITH BYPASS, FLANGED FLANGED ANGLE BALL VALVE AND PADLOCK WINGS ANGLE BALL VALVE AND PADLOCK WINGS ON INLET, ON INLET, ANGLE CHECK VALVE ON OUTLET, AND ANGLE CHECK VALVE ON OUTLET, AND BALL VALVE BALL VALVE ON BYPASS WITH PADLOCK WINGS, ON BYPASS WITH PADLOCK WINGS, FORD VBH86-12B-11-66-Q-NL, A.Y. MCDONALD FORD VBH87-12B-11-77-Q-NL, A.Y. MCDONALD 730B-612WDFF665, OR MUELLER B-2427N (1 %2"), 730B-612WDFF665, OR MUELLER B-2427N (2"), BYPASS NOT PERMITTED ON IRRIGATION METERS BYPASS NOT PERMITTED ON IRRIGATION METERS 13 %6" RIGID METER SPREADER (TEMPORARY) 17 3/6" RIGID METER SPREADER (TEMPORARY) AMI WATER METER WITH RADIO AND BATTERY UNIT, AMI WATER METER WITH RADIO AND BATTERY UNIT, TO BE SUPPLIED AND INSTALLED BY CITY FORCES TO BE SUPPLIED AND INSTALLED BY CITY FORCES 17"X30" METER BOX, ARMORCAST A6001640PCX18, 17"X30" METER BOX, ARMORCAST A6001640PCX18, WITH METER BOX LID, ARMORCAST WITH METER BOX LID, ARMORCAST A6001947RCI-H7, TO READ "RENTON WATER" A6001947RCI-H7, TO READ "RENTON WATER" 1 %2" COUPLER (PACK JOINT x PACK JOINT), FORD 2" COUPLER (PACK JOINT x PACK JOINT), FORD C4#-6#-Q-NL OR EQUAL, WITH GALVANIZED PLUG IF C4#-7#-Q-NL OR EQUAL, WITH GALVANIZED PLUG IF PRIVATE SERVICE LINE IS NOT YET INSTALLED PRIVATE SERVICE LINE IS NOT YET INSTALLED CRUSHED ROCK BASE TO SUPPORT METER BOX, CRUSHED ROCK BASE TO SUPPORT METER BOX, METER BYPASS TO BE EXPOSED METER BYPASS TO BE EXPOSED PUBLIC WORKS I Y2" AND 2" WATER SERVICE DEPARTMENT IN PLANTING STRIP 2" WATER SERVICE STD. PLAN - 320.2 P.—ha DATE Works Admini—, NTS 0 CI C\/A-rinAl MIN �� �� STD. PLAN - 350.3 Sht. 1 of 2 3 TO10 DCDA APPROVED: • PUBLIC WORKS VAULT INSTALLATION � DEPARTMENT 6/28/2023 FIRE SPRINKLER SYSTEMS Martin Pwtdtha w blic wor Adm,mstrator DATE REVISION 2 C-510 DOUBLE CHECK DETECTOR ASSEMBLY SURVEYED: 04/01/21 DESIGNED: BB/AT/HD DRAWN: BB/AT/HD CHECKED: cm BY I DATE I AP P R I APPROVED: SCALE: AS SHOWN ONE INCH AT FULL SCALE IF NOT ONE INCH SCALE ACCORDINGLY VERTICAL: NAVD 1988 HORIZONTAL: NAD 1983/1991 DATU M NOTES: 1. THE DCDA MUST BE LISTED ON THE LATEST VERSION OF "BACKFLOW ASSEMBLIES APPROVED FOR INSTALLATION IN WASHINGTON STATE", PUBLISHED BY THE STATE OF WASHINGTON DEPARTMENT OF HEALTH. 2. THE DCDA MUST BE TESTED BY A WASHINGTON STATE CERTIFIED BACKFLOW ASSEMBLY TESTER UPON INSTALLATION AND ANNUALLY THEREAFTER. ASSEMBLY TO BE MAINTAINED BY PROPERTY OWNER. A COPY OF THE TEST REPORT SHALL BE SENT TO THE CITY OF RENTON WATER UTILITY CROSS CONNECTION CONTROL SPECIALIST, FAX 425-430-7207, EMAIL BACKFLOW@RENTONWA.GOV. 3. VAULTS SHALL NOT BE INSTALLED IN AREAS WITH VEHICLE TRAFFIC. 4. VAULT AND HATCH MODELS ARE PROVIDED AS REFERENCE. SHOP DRAWINGS SHALL BE SUBMITTED TO THE CITY FOR APPROVAL. 5. TEE AND GATE VALVE REQUIRED ON MAIN. 6. WHEN DCDA IS USED IN THE SAME LINE AS THE DOMESTIC BUILDING METER, THE METERED BYPASS SHALL BE OMITTED. 7. MINIMUM T OF LEVEL, UNOBSTRUCTED AREA AROUND HATCHES. 8. FDC TO BE LOCATED DOWNSTREAM OF DCDA. FDC LINE AND CHECK VALVE MAY BE ROUTED INSIDE THE DCDA VAULT PROVIDED THE VAULT IS ADEQUATELY SIZED AND ALL PROVISIONS OF STD PLAN 370.2 ARE MET. 9. LONGER VALVE ASSEMBLIES MAY REQUIRE A LARGER VAULT TO MEET REQUIRED CLEARANCES. SUBMIT FOR APPROVAL. 10. EACH VALVE SHALL BE MARKED WITH MODEL NUMBER WITH DESIGNATION OF RESILIENT SEAT: SUCH AS "RS" OR "R", WHICH MUST BE CAST, MOLDED, OR AFFIXED ONTO THE BODY OR BONNET OF THE VALVE. ALL FERROUS BODIED VALVES SHALL BE COATED WITH A MINIMUM OF 4 MILS OF EPDXY OR EQUIVALENT POLYMERIZED COATING. MATERIALS LINE -SIZED WASHINGTON STATE -APPROVED DCDA WITH TWO (2) RESILIENT -SEATED SHUT-OFF VALVES DOUBLE CHECK AND FOUR (4) RESILIENT -SEATED TEST COCKS, DCDA SHALL BE INSTALLED EQUIDISTANT FROM THE ENDS DETECTOR ASSEMBLY OF THE CONCRETE VAULT, TWO (2) VALVE SUPERVISORY SWITCHES (ONE PER VALVE) PER RRFA REQUIREMENTS OB BYPASS 3/4" DETECTOR BYPASS, ALL MATERIALS TO BE BRASS OR COPPER OC BYPASS METER 3/4" AMI WATER METER WITH RADIO AND BATTERY UNIT, TO BE PROVIDED BY THE CITY ODOUBLE CHECK 3/4" WASHINGTON STATE -APPROVED DCVA WITH TWO (2) RESILIENT -SEATED SHUT-OFF VALVES AND FOUR VALVE ASSEMBLY (4) RESILIENT -SEATED TEST COCKS OE PIPE SUPPORT ADJUSTABLE PIPE SADDLE SUPPORT, GRINNELL FIG. 264 OR EQUAL, WITH BASE, BOLTED TO FLOOR OF ADAPTER RESTRAINED FLANGE ADAPTER, EBAA IRON SERIES 2100 MEGAFLANGE OR EQUAL GO WATER MAIN CLASS 53 DI PIPE (PExFL) WITH RESTRAINED JOINTS OH WALL FLANGE MIDSPAN PIPE RESTRAINT WITH CONCRETE BLOCKING PER STD PLAN 370.4, SEAL PIPE PENETRATIONS WITH WATER -TIGHT GROUT OI CONCRETE VAULT OLDCASTLE PRECAST VAULT, MODEL NUMBERS PER TABLE BELOW, OR EQUAL MINIMUM 6" PVC FLOOR DRAIN, SLOPE TO STORM DRAIN OR DAYLIGHT TO DRAINAGE DITCH WITH WIRE JO DRAIN MESH RODENT SCREEN AT DRAIN OUTLET, SEAL PIPE PENETRATION WITH WATER -TIGHT GROUT OK ACCESS HATCH TWO LOCKING HINGED ALUMINUM DOORS, TRAFFIC -RATED, WITH SLIP -RESISTANT TREATMENT, MARKED "WATER", LW PRODUCTS MODEL NUMBERS PER TABLE BELOW, OR EQUAL OL LADDER GALVANIZED STEEL LADDER SECURED TO VAULT PER STD PLAN 370.5 MO GRAVEL FOUNDATION GRAVEL PER WSDOT STANDARD SPECIFICATIONS, 12" MINIMUM ALL DIRECTIONS VAULT MODEL NUMBERS DCVA SIZE VAULT BASE PIECE CENTER PIECE TOP PIECE ACCESS HATCH 3" 675-WA NO.675-BL NO. 675-MLW NO. 675-TL-2-332P HHD-1C 4" 675-WA NO.675-BL NO. 675-MLW NO. 675-TL-2-332P HHD-1C 6" 675-WA NO.675-BL NO.675-MLW NO. 675-TL-2-332P HHD-1C 8" 687-LA NO.687-BL NO.687-ML NO.687-TL-2-332P HHD-2D 101' 5106-LA NO.5106-BL NO.5106-ML NO.5106-TL3-332 HHD-2D �� �� STD. PLAN - 350.3 Sht. 2 of 2 3 TO 10 DCDA APPROVED: PUBLIC WORKS VAULT INSTALLATION �r DEPARTMENT 6/28/2023 FIRE SPRINKLER SYSTEMS Martin Pastdcha Public WorksAdministrator DATE NTS • CITY OF RENTON VASVR Planning/Building/Public Works Dept. C) Nt N " U L0 r 1 N Q J m Q0 r C) 0 M NNN I..L W-432703 I— O IN COMPLIANCE WITH CITY OF RENTON STANDARDS J C� Eyq:i MENT ENGINEERING �' Z 05/13/2025 �e ry Q Fe ER UTILITY z 05/06/2025 _ DATE: 600 SW 10TH PARKING LOT 0OOK: 025 r FlELDBOK: PAGE: WATER DETAILS DRAWING NO: C-510 0 SHEET: 19 OF: 28 O Cfl