HomeMy WebLinkAboutP_Civil_Construction_Plans_250606_ApprovedLEGAL DESCRIPTION LINDBERGH HIGH SCHOOL GENERAL NOTES FIELD IMPROVEMENTS PROJECT NOTES VICINITY MAP CITY OF RENTON IN COMPLIANCE WITH CITY OF RENTON STANDARDS TE D - 4 0 - 4 3 4 4 43667 NSTATE O F WASHI N G T ON R EGIST E R E D P R O F E SSIONAL E N G IN EER O S B O CAJA.DLAREJ LU A 2 5 - 0 0 0 0 5 1 PR 2 5 - 0 0 0 0 1 8 C2 5 0 0 0 9 7 7 ACW JAJ ACW JAJ ACW JAJ 1.THE CONTRACTOR SHALL TAKE REASONABLE PRECAUTIONS AND EXERCISE SOUND ENGINEERING AND CONSTRUCTION PRACTICES IN CONDUCTING THE WORK. THE CONTRACTOR SHALL PROTECT EXISTING PUBLIC AND PRIVATE UTILITIES FROM DAMAGE DURING CONSTRUCTION. IF EXISTING UTILITIES ARE DAMAGED, THE CONTRACTOR SHALL IMMEDIATELY NOTIFY THE UTILITY PURVEYOR, OWNER AND THE ENGINEER. THE CONTRACTOR SHALL RESTORE THE UTILITY TO ITS EXISTING CONDITION. (WSDOT SEC. 1-07.17 APWA SUPPLEMENT). THE CONTRACTOR IS RESPONSIBLE FOR THE MEANS AND THE METHODS OF CONSTRUCTION FOR WORK SHOWN ON THESE PLANS. 2.ALL EXCAVATION, TRENCHING, SUBGRADE PREPARATION, FILL PLACEMENT, AND ALL SOIL WORK IN GENERAL SHALL BE CONDUCTED IN COMPLIANCE WITH THE CITY OF RENTON STANDARDS. 3.CONTRACTOR SHALL BE RESPONSIBLE FOR HIRING A PROFESSIONAL LAND SURVEYOR TO REFERENCE EXISTING MONUMENTS ON OR ADJOINING ESTABLISHED SAID POINTS AT PROJECT COMPLETION. THIS REESTABLISHMENT SHALL BE DOCUMENTED BY RECORD OF SURVEY PREVIOUS TO DEMOLITION OR CONSTRUCTION AND TO RECORNER RECORD AS DESCRIBED IN W.A.C. 332-120. 4.CONTRACTOR SHALL MAINTAIN A 5 FOOT MINIMUM HORIZONTAL CLEARANCE FROM THE WATER MAIN AND OTHER UTILITIES (i.e. GAS, CABLE, POWER, ETC.). IF SAID CLEARANCE CANNOT BE MAINTAINED, CONTACT ENGINEER FOR APPROVAL AND RECORD EXACT MEASUREMENTS OF THE UTILITY LINES ON THE AS-BUILT DRAWINGS. A 10 FOOT MINIMUM HORIZONTAL CLEARANCE MUST BE MAINTAINED BETWEEN WATER MAIN AND SANITARY SEWER. 5.SCHEDULE WITH SOOS CREEK WATER AND SEWER DISTRICT AND OWNER (96 HOURS MINIMUM NOTICE FOR WATER MAIN SHUT DOWN ON THE SCHOOL SITE). INSTALL CITY STANDARD TESTING CONNECTION ON NEW WATER MAIN FOLLOWING COMPLETION OF NEW WATER SYSTEM CONSTRUCTION, TESTING, AND ACCEPTANCE BY THE CITY, REMOVE TESTING CONNECTION AND INSTALL SEGMENT OF DI PIPE, LENGTH TO SUIT, WITH TWO LONG PATTERN SLEEVES. INSTALLATION AND CONNECTION TO EXISTING WATER SYSTEM SHALL BE WITH 100% CITY INSPECTION. 6.UNDERGROUND UTILITIES ARE SHOWN IN THE APPROXIMATE LOCATION. THERE IS NOT A GUARANTEE THAT ALL UTILITY LINES ARE SHOWN OR THAT THE LOCATION, SIZE, AND MATERIAL IS ACCURATE. THE CONTRACTOR SHALL UNCOVER ALL INDICATED PIPING WHERE CROSSINGS, INTERFERENCE'S OR CONNECTIONS OCCUR PRIOR TO TRENCHING OR EXCAVATION FOR ANY PIPE OR STRUCTURES, TO DETERMINE ACTUAL LOCATIONS, SIZE AND MATERIAL. THE CONTRACTOR SHALL MAKE THE APPROPRIATE PROVISION FOR PROTECTION OF SAID FACILITIES. THE CONTRACTOR SHALL NOTIFY ONE CALL AT 811 AND ARRANGE FOR PUBLIC AND PRIVATE FIELD LOCATION OF EXISTING FACILITIES BEFORE CONSTRUCTION. 7.SCHEDULE WITH CITY (48 HOURS MINIMUM NOTICE) FOR WATER METER SHUTOFF AND TO RETIRE METERS. 1.ALL WORK SHALL CONFORM TO THE DESIGN AND CONSTRUCTION STANDARDS AND SPECIFICATIONS FOR CITY OF RENTON. A COPY OF THESE DOCUMENTS SHALL BE ON SITE DURING CONSTRUCTION. 2.A COPY OF THE APPROVED PLANS MUST BE ON SITE WHENEVER CONSTRUCTION IS IN PROGRESS. 3.ERRORS AND OMISSIONS ON THE PERMITTED PLANS MUST BE CORRECTED BY THE ENGINEER AND APPROVED BY THE CITY OF RENTON. 4.ALL PERMITS REQUIRED FOR WORK WITHIN THE PUBLIC RIGHT OF WAY MUST BE OBTAINED BY THE CONTRACTOR PRIOR TO THE START OF CONSTRUCTION. 5.PRIOR TO THE START OF CONSTRUCTION WITHIN THE RIGHT OF WAY, THE CONTRACTOR SHALL SCHEDULE AND ATTEND A PRECONSTRUCTION MEETING WITH THE CITY OF RENTON. THE OWNER, RECORD ENGINEER, CONTRACTOR AND DESIGNATED SUBCONTRACTORS SHALL BE PRESENT AT THE PRECONSTRUCTION MEETING. 6.EXISTING PAVED SURFACES INCLUDING ROADWAYS, SIDEWALKS, AND CURBS THAT ARE DAMAGED BY NEW CONSTRUCTION SHALL BE REPAIRED AS REQUIRED BY CITY OF RENTON AND THEIR INSPECTORS. 7.ALL DAMAGE TO CITY INFRASTRUCTURE CAUSED BY THE CONSTRUCTION SHALL BE REPAIRED AS REQUIRED BY THE CITY OF RENTON. 8.THE APPROVED PLANS SHOW THE APPROXIMATE AREA OF PAVEMENT RESTORATION BASED ON THE DEPTH OF UTILITY CUTS AND/OR THE AREA OF CURB AND/OR PAVEMENT TO BE REMOVED AND REPLACED. THE ACTUAL LIMITS OF THE PAVEMENT RESTORATION SHALL BE DETERMINED IN THE FIELD BY THE CITY OF RENTON INSPECTORS PRIOR TO THE PAVEMENT RESTORATION. 9.SURVEYING AND STAKING OF ALL IMPROVEMENTS IN THE PUBLIC RIGHT OF WAY SHALL BE COMPLETED PRIOR TO CONSTRUCTION. SURVEY CUT SHEETS MUST BE COORDINATED WITH CITY OF RENTON INSPECTORS AT LEAST 5 DAYS PRIOR TO CONSTRUCTION. 10.IF AN EXISTING CURB IS TO BE REMOVED AND REPLACED IN THE SAME LOCATION THE CONTRACTOR SHALL PROVIDE THE CITY OF RENTON INSPECTOR A PLAN WITH EXISTING FLOW LINE AND TOP OF CURB ELEVATIONS IDENTIFIED. PERMITTEE TO STAKE THE LOCATION OF THE EXISTING CURB PRIOR TO DEMOLITION. 11.THE CONTRACTOR SHALL BE RESPONSIBLE FOR REFERENCING AND REPLACING ALL MONUMENTS THAT MAY BE DISTURBED, DESTROYED OR REMOVED BY THE PROJECT AND SHALL FILE AN APPLICATION FOR PERMIT TO REMOVE OR DESTROY A SURVEY MONUMENT WITH THE WASHINGTON STATE DEPARTMENT OF NATURAL RESOURCES, PURSUANT TO RCW 58.24.040(8). 12.THE CONTRACTOR SHALL SUBMIT ALL APPLICABLE DOCUMENTS AS REQUIRED PER THE CITY OF RENTON DESIGN AND CONSTRUCTION STANDARDS AND SPECIFICATIONS PRIOR TO CONSTRUCTION. A MATERIAL SOURCE FORM FOR ALL MATERIALS TO BE PLACED IN THE RIGHT OF WAY AND MIX DESIGNS FOR ALL ASPHALT, CONCRETE AND AGGREGATES TO BE PLACED IN THE RIGHT OF WAY MUST BE SUBMITTED TO THE CITY OF RENTON FOR REVIEW AND APPROVAL PRIOR TO BEGINNING CONSTRUCTION. 13.THE CONTRACTOR SHALL NOTIFY THE KING COUNTY FIRE PROTECTION DISTRICT NO. 40 AT LEAST TWENTY-FOUR (24) HOURS IN ADVANCE OF ALL WATER SERVICE INTERRUPTIONS, HYDRANT SHUTOFFS, AND STREET CLOSURES OR OTHER ACCESS BLOCKAGE. THE CONTRACTOR SHALL ALSO NOTIFY THE FIRE DISTRICT OF ALL NEW, RELOCATED, OR ELIMINATED HYDRANTS RESULTING FROM THIS WORK. 14.THE CONTRACTOR SHALL LOCATE AND PROTECT ALL CASTINGS AND UTILITIES DURING CONSTRUCTION. 15.THE CONTRACTOR SHALL CONTACT THE UNDERGROUND UTILITIES LOCATOR SERVICE (811) AT LEAST 48 HOURS PRIOR TO CONSTRUCTION. 16.THE CONTRACTOR SHALL CONTACT A PRIVATE UTILITY LOCATOR FOR ALL ON-SITE WORK ON THE PROJECT AND ADJACENT PRIVATE PROPERTIES, AT LEAST 48 HOURS PRIOR TO CONSTRUCTION. 17.IT IS THE SOLE RESPONSIBILITY OF THE CONTRACTOR TO VERIFY THE ACCURACY OF ALL UTILITY LOCATIONS SHOWN AND TO FURTHER DISCOVER AND AVOID ANY OTHER UTILITIES NOT SHOWN WHICH MAY BE AFFECTED BY THE IMPLEMENTATION OF THIS PLAN. THIS MAY INCLUDE, BUT IS NOT LIMITED TO, POTHOLE EXCAVATION AND OTHER MEANS AND METHODS. 18.THE CONTRACTOR SHALL ADJUST ALL EXISTING AND PROPOSED MANHOLE RIMS, DRAINAGE STRUCTURE LIDS, VALVE BOXES, AND UTILITY ACCESS STRUCTURES TO FINISH GRADE WITHIN AREAS AFFECTED BY THE PROPOSED IMPROVEMENTS. THIS INCLUDES AS REQUIRED DURING PHASING TO ACCOMMODATE INTERIM AND FINAL GRADING 19.UTILITY SERVICE CONNECTIONS SHOWN ON THE PLANS REQUIRE SEPARATE PERMITS FROM THE CEDAR RIVER WATER AND SEWER DISTRICT AND ARE TO BE OBTAINED BY THE CONTRACTOR, AND ARE NOT COORDINATED BY OR OBTAINED BY KING COUUNTY DPER. 20.THE CONTRACTOR SHALL PROVIDE FOR ALL TESTING AS REQUIRED BY THE CITY OF RENTON INSPECTOR. 21.BACKFILL MATERIAL USED IN PUBLIC RIGHT-OF-WAY SHALL MEET STANDARD SPECIFICATIONS AND SHALL BE APPROVED BY THE CITY OF RENTON. 22.INSPECTION AND ACCEPTANCE OF ALL WORK IN THE PUBLIC RIGHT-OF-WAY SHALL BE DONE BY REPRESENTATIVES OF CITY OF RENTON. IT SHALL BE THE CONTRACTORS RESPONSIBILITY TO COORDINATE AND SCHEDULE APPROPRIATE INSPECTIONS ALLOWING FOR PROPER ADVANCE NOTICE. THE CITY OF RENTON INSPECTOR MAY REQUIRE REMOVAL AND RECONSTRUCTION OF ANY ITEMS PLACED IN THE RIGHT OF WAY THAT DO NOT MEET COUNTY STANDARDS OR THAT WERE CONSTRUCTED WITHOUT APPROPRIATE INSPECTIONS. 23.THE CONTRACTOR SHALL PROVIDE AND MAINTAIN TEMPORARY EROSION CONTROL AND SEDIMENTATION COLLECTION FACILITIES TO ENSURE THAT SEDIMENT-LADEN WATER DOES NOT ENTER THE NATURAL OR PUBLIC DRAINAGE SYSTEM. AS CONSTRUCTION PROGRESSES AND UNEXPECTED (SEASONAL) CONDITIONS DICTATE, ADDITIONAL CONTROL FACILITIES MAY BE REQUIRED. DURING THE COURSE OF CONSTRUCTION IT SHALL BE THE OBLIGATION AND RESPONSIBILITY OF THE CONTRACTOR TO ADDRESS ANY NEW CONDITIONS THAT MAY BE CREATED BY THE CONTRACTORS ACTIVITIES AND TO PROVIDE ADDITIONAL FACILITIES THAT MAY BE NEEDED TO PROTECT ADJACENT PROPERTIES. 24.THE CONTRACTOR SHALL KEEP ALL PAVED SURFACES IN THE RIGHT OF WAY CLEAN BY SWEEPING. USE VACUUM TYPE SWEEPER 25.CARE SHALL BE EXERCISED WHEN EXCAVATING NEAR EXISTING CHARGED WATER MAINS. 26.ALL UTILITY CROSSINGS NOTED AS "ASSUMED" ARE UNKNOWN DURING DESIGN. THE UNKNOWN ELEVATIONS AND LOCATIONS MUST BE VERIFIED PRIOR TO ANY UTILITY CONSTRUCTION. ELEVATIONS THAT DIFFER FROM ASSUMED ELEVATION SHALL BE FORWARDED TO THE CIVIL ENGINEER FOR REVIEW. PARCEL A: THE EAST 500 FEET OF THE NORTH 1121 FEET OF THE SOUTHEAST QUARTER OF THE NORTHEAST QUARTER OF SECTION 28, TOWNSHIP 23 NORTH, RANGE 5 EAST OF THE WILLAMETTE MERIDIAN, IN KING COUNTY, WASHINGTON. PARCEL B: THE EASTERLY 330 FEET OF THE SOUTHERLY 216.47 FEET, MORE OR LESS, OF SOUTHEAST QUARTER OF THE NORTHEAST QUARTER OF SECTION 28, TOWNSHIP 23 NORTH, RANGE 5 EAST OF THE WILLAMETTE MERIDIAN, IN KING COUNTY, WASHINGTON. PARCEL C: THE SOUTHEAST QUARTER OF THE NORTHEAST QUARTER OF SECTION 28, TOWNSHIP 23 NORTH, RANGE 5 EAST OF THE WILLAMETTE MERIDIAN, IN KING COUNTY, WASHINGTON; EXCEPTING THEREFROM THE EAST 500 FEET OF THE NORTH 1121 FEET; ALSO EXCEPTING THEREFROM THE EAST 330 FEET OF THE SOUTH 216.47 FEET; ALSO EXCEPTING THEREFROM THE SOUTH 250 FEET OF THE EAST 523 FEET OF THE WEST 553 FEET; ALSO EXCEPTING THEREFROM ANY PORTION LYING WITHIN THE BOUNDARIES OF 128TH AVENUE SE. LANDSCAPE: ARCHITECT DA HOGAN & ASSOCIATES 1450 114TH AVE SE, FLOOR 1 BELLEVUE, WA 98004 (206)285-0400 CONTACT: ERIC GOLD ERICG@DAHOGAN.COM CIVIL ENGINEER: JACOBSON CONSULTING ENGINEERS 255 S. KING STREET, SUITE 800 SEATTLE, WA 98104 (206) 426-2600 CONTACT: ALAN JACOBSON ALAN@JACOBSONENGINEERS.COM ELECTRICAL ENGINEER: METRIX ENGINEERS 227 WILLIAMS AVE S RENTON, WA 98057 (425)336-2822 CONTACT: BEN PREHODA BENP@METRIXENG.COM NOTE: 1.THE QUANTITIES SHOWN ARE PRELIMINARY ESTIMATES ONLY AND INTENDED FOR MUNICIPAL PERMITTING AND REVIEW FEES. THE CONTRACTOR SHALL IGNORE THESE QUANTITIES, THEY ARE EXCLUDED FROM THE BID DOCUMENT INFORMATION. THESE VOLUMES SHALL NOT BE USED BY THE CONTRACTOR AS A BASIS FOR ANY CONTRACTUAL INFORMATION. THE CONTRACTOR SHALL PREPARE THEIR OWN EARTHWORK QUANTITIES BASED ON THE INFORMATION PROVIDED IN THE CONTRACT DOCUMENTS, INCLUDING BUT NOT LIMITED TO DRAWINGS, SPECIFICATIONS, AND THE GEOTECHNICAL REPORT. 2.INCLUDES APPROXIMATELY 5,092 CY FOR FIELD EXCAVATION (PER TYP FIELD SECTION) AND ROUGHLY 5,134 CY FOR EXCAVATION OF DETENTION SYSTEMS FOR FIELDS. 3.INCLUDES APPROXIMATELY 3,275 CY FOR BACKFILL FOR DETENTION SYSTEMS FOR FIELDS. EARTHWORK QUANTITIES EXCAVATION 2 12,783 CY FILL 3 10,459 CY TOTAL EARTHWORK 23,242 CY SITE INFORMATION DATUM SITE ADDRESS: 16426 128TH AVE SE RENTON, WA 98058 PARCEL NUMBERS: 282305-9004 HORIZONTAL DATUM: NAVD 83 (91) WASHINGTON STATE PLANE NORTH ZONE VERTICAL DATUM: NAVD '88 CITY OF RENTON VERTICAL CONTROL NETWORK DOES NOT EXTEND INTO SECTION 28. ELEVATIONS FOR ESM BENCHMARK POINT NOS. 100 AND 122 DERIVED FROM GPS OBSERVATION. ARCHITECT:MCGRANAHAN ARCHITECTS 2111 PACIFIC AVE #100 TACOMA, WA 98402 (253)383-3084 CONTACT: KRIS STAMON KRIS.STAMON@MCGRANAHAN.COM ZONING: R-6 RESIDENTIAL 6 DU/ACRE PARCEL AREAS: 37.25 AC C000 COVER SHEET C001 NOTES SHEET C010 OVERALL SITE PLAN C011 PROJECT AREA OVERALL C012 PAVEMENT MARKINGS PLAN C101 DEMOLITION AND TESC PLAN NORTH C102 DEMOLITION AND TESC PLAN SOUTH C110 TESC DETAILS C201 GRADING AND DRAINAGE PLAN NORTH C202 GRADING AND DRAINAGE PLAN SOUTH C210 STORM DRAINAGE DETAILS C211 STORM DRAINAGE DETAILS C212 STORM DRAINAGE DETAILS C213 GRADING & STORM DRAINAGE DETAILS C220 STORM DRAINAGE PROFILES C221 STORM DRAINAGE PROFILES F001 LAND USE SITE PLAN F002 COMPOSITE UTILITY PLAN F010 BASEBALL SITE PREPARATION PLAN F011 SOFTBALL SITE PREPARATION PLAN F100 FIELD COLOR PLANS F110 BASEBALL LAYOUT PLAN F111 SOFTBALL LAYOUT PLAN F120 BASEBALL GRADING PLAN F121 SOFTBALL GRADING PLAN F130 BASEBALL DRAINAGE PLAN F131 SOFTBALL DRAINAGE PLAN F140 BASEBALL IRRIGATION & WASHWATER PLAN F141 SOFTBALL IRRIGATION & WASHWATER PLAN F210 TYPICAL SECTIONS F220 SITE DETAILS F221 SITE DETAILS F222 SITE DETAILS F230 FENCING DETAILS F231 BALL CONTROL NET REPLACEMENT DETAILS F240 DUGOUT DETAILS F250 BULLPEN DETAILS F251 BATTING CAGE DETAILS F260 WASHWATER DETAILS F270 SITE STAIR DETAILS F310 BASEBALL LAYOUT PLAN & DETAILS F320 SOFTBALL LAYOUT PLAN & DETAILS IN THE NW 1/4 OF SECTION 28, TOWNSHIP 23 NORTH, RANGE 05 EAST, W.M. OWNER:RENTON SCHOOL DISTRICT CAPITAL PLANNING & CONSTRUCTION 7812 SOUTH 124TH STREET SEATTLE, WA 98178 (425)204-4437 CONTACT: ANDREW HOLLENBACK ANDREW.HOLLENBACK@RENTONSCHOOLS.US LINDBERGH HIGH SCHOOL FIELD IMPROVEMENTS COVER SHEET SOOS CREEK WATER & SEWER DISTRICT 14616 SE 192ND ST RENTON, WA 98058 (253)630-9900 WATER/SEWER PURVEYOR: Sheet List Table R-434401 CIVIL CONSTRUCTION PERMIT CIVIL CONSTRUCTION PERMIT RESUBMITTAL CIVIL CONSTRUCTION PERMIT RESUBMITTAL 2/21/25 4/14/25 6/06/25 DEVELOPMENT ENGINEERING HBray 06/24/2025 Surface Water Enginering jfarah 06/24/2025 amorganroth 06/24/2025 CURRENT PLANNING REGIONAL FIRE AUTHORITY cthomas 06/25/2025 APPROVED IN THE NW 1/4 OF SECTION 28, TOWNSHIP 23 NORTH, RANGE 05 EAST, W.M. CITY OF RENTON IN COMPLIANCE WITH CITY OF RENTON STANDARDS TE D - 4 0 - 4 3 4 4 43667 NSTATE O F WASHI N G T ON R EGIST E R E D P R O F E SSIONAL E N G IN EER O S B O CAJA.DLAREJ LU A 2 5 - 0 0 0 0 5 1 PR 2 5 - 0 0 0 0 1 8 C2 5 0 0 0 9 7 7 ACW JAJ ACW JAJ ACW JAJ THE FOLLOWING IS A LISTING OF GENERAL NOTES THAT SHALL BE INCORPORATED IN THE EROSION AND SEDIMENT CONTROL ( ESC) PLAN SET. ALL THE NOTES ON THE LIST MAY NOT PERTAIN TO EVERY PROJECT. THE APPLICANT OR OWNER, HEREBY REFERRED TO AS APPLICANT, MAY STRIKE OUT IRRELEVANT NOTES IF NOT APPLICABLE TO THE PROJECT. HOWEVER, THE APPLICANT SHALL NOT RENUMBER NOR EDIT THE REMAINING NOTES. IF ADDITIONAL NOTES ARE NEEDED FOR SPECIFIC ASPECTS, THEY SHALL BE ADDED AFTER THE ESC STANDARD PLAN NOTES. 1.BEFORE ANY CONSTRUCTION OR DEVELOPMENT ACTIVITY OCCURS, A PRE- CONSTRUCTION MEETING SHALL BE HELD AMONG THE CITY OF RENTON, HEREBY REFERRED TO AS THE CITY, THE APPLICANT, AND THE APPLICANT' S CONTRACTOR. 2.THE APPLICANT IS RESPONSIBLE FOR OBTAINING THE WASHINGTON STATE DEPARTMENT OF ECOLOGY (ECOLOGY) CONSTRUCTION STORMWATER GENERAL PERMIT, IF IT IS REQUIRED FOR THE PROJECT. THE APPLICANT SHALL PROVIDE THE CITY COPIES OF ALL MONITORING REPORTS PROVIDED TO ECOLOGY ASSOCIATED WITH THE CONSTRUCTION STORMWATER GENERAL PERMIT. 3.THE ESC PLAN SET SHALL INCLUDE AN ESC CONSTRUCTION SEQUENCE DETAILING THE ORDERED STEPS THAT SHALL BE FOLLOWED FROM CONSTRUCTION COMMENCEMENT TO POST- PROJECT CLEANUP IN ORDER TO FULFILL PROJECT ESC REQUIREMENTS. 4.THE BOUNDARIES OF THE CLEARING LIMITS, SENSITIVE AREAS AND THEIR BUFFERS, AND AREAS OF VEGETATION PRESERVATION AND TREE RETENTION AS PRESCRIBED ON THE PLAN( S) SHALL BE CLEARLY DELINEATED BY FENCING AND PROTECTED IN THE FIELD IN ACCORDANCE WITH APPENDIX D OF THE CITY OF RENTON SURFACE WATER DESIGN MANUAL ( RENTON SWDM) PRIOR TO THE START OF CONSTRUCTION. DURING THE CONSTRUCTION PERIOD, NO DISTURBANCE BEYOND THE CLEARING LIMITS SHALL BE PERMITTED. THE CLEARING LIMITS SHALL BE MAINTAINED BY THE APPLICANT/ ESC SUPERVISOR FOR THE DURATION OF CONSTRUCTION. 5.STABILIZED CONSTRUCTION ENTRANCES SHALL BE INSTALLED AT THE BEGINNING OF CONSTRUCTION AND MAINTAINED FOR THE DURATION OF THE PROJECT. ADDITIONAL MEASURES, SUCH AS CONSTRUCTED WHEEL WASH SYSTEMS OR WASH PADS, MAY BE REQUIRED TO ENSURE THAT ALL PAVED AREAS ARE KEPT CLEAN AND TRACK- OUT TO ROAD RIGHT OF WAY DOES NOT OCCUR FOR THE DURATION OF THE PROJECT. IF SEDIMENT IS TRACKED OFFSITE, PUBLIC ROADS SHALL BE CLEANED THOROUGHLY AT THE END OF EACH DAY, OR MORE FREQUENTLY DURING WET WEATHER, AS NECESSARY TO PREVENT SEDIMENT FROM ENTERING WATERS OF THE STATE. 6.WASHOUT FROM CONCRETE TRUCKS SHALL BE PERFORMED OFF- SITE OR IN DESIGNATED CONCRETE WASHOUT AREAS ONLY. DO NOT WASH OUT CONCRETE TRUCKS ONTO THE GROUND, OR TO STORM DRAINS OR OPEN DITCHES. ON- SITE DUMPING OF EXCESS CONCRETE SHALL ONLY OCCUR IN DESIGNATED CONCRETE WASHOUT AREAS. 7.WASHOUT AREAS. ALL REQUIRED ESC BMPS SHALL BE CONSTRUCTED AND IN OPERATION PRIOR TO LAND CLEARING AND/ OR CONSTRUCTION TO PREVENT TRANSPORTATION OF SEDIMENT TO SURFACE WATER, DRAINAGE SYSTEMS AND ADJACENT PROPERTIES. ALL ESC BMPS SHALL BE MAINTAINED IN A SATISFACTORY CONDITION UNTIL SUCH TIME THAT CLEARING AND/ OR CONSTRUCTION IS COMPLETE AND POTENTIAL FOR ON- SITE EROSION HAS PASSED. ALL ESC BMPS SHALL BE REMOVED AFTER CONSTRUCTION IS COMPLETED AND THE SITE HAS BEEN STABILIZED TO ENSURE POTENTIAL FOR ON- SITE EROSION DOES NOT EXIST. THE IMPLEMENTATION, MAINTENANCE, REPLACEMENT, ENHANCEMENT, AND REMOVAL OF ESC BMPS SHALL BE THE RESPONSIBILITY OF THE APPLICANT. 8.ANY HAZARDOUS MATERIALS OR LIQUID PRODUCTS THAT HAVE THE POTENTIAL TO POLLUTE RUNOFF SHALL BE DISPOSED OF PROPERLY. 9.THE ESC BMPS DEPICTED ON THIS DRAWING ARE INTENDED TO BE MINIMUM REQUIREMENTS TO MEET ANTICIPATED SITE CONDITIONS. AS CONSTRUCTION PROGRESSES AND UNEXPECTED OR SEASONAL CONDITIONS DICTATE, THE APPLICANT SHALL ANTICIPATE THAT MORE ESC BMPS WILL BE NECESSARY TO ENSURE COMPLETE SILTATION CONTROL ON THE PROPOSED SITE. DURING THE COURSE OF CONSTRUCTION, IT SHALL BE THE OBLIGATION AND RESPONSIBILITY OF THE APPLICANT TO ADDRESS ANY NEW CONDITIONS THAT MAY BE CREATED BY THE ACTIVITIES AND TO PROVIDE ADDITIONAL ESC BMPS, OVER AND ABOVE MINIMUM REQUIREMENTS, AS MAY BE NEEDED, TO PROTECT ADJACENT PROPERTIES AND WATER QUALITY OF THE RECEIVING DRAINAGE SYSTEM. 10.APPROVAL OF THIS PLAN IS FOR ESC ONLY. IT DOES NOT CONSTITUTE AN APPROVAL OF STORM DRAINAGE DESIGN, SIZE NOR LOCATION OF PIPES, RESTRICTORS, CHANNELS, OR STORMWATER FACILITIES. 11.ANY DEWATERING SYSTEM NECESSARY FOR THE CONSTRUCTION OF STORMWATER FACILITIES SHALL BE SUBMITTED TO THE CITY FOR REVIEW AND APPROVAL. 12.ANY AREAS OF EXPOSED SOILS, INCLUDING ROADWAY EMBANKMENTS, THAT WILL NOT BE DISTURBED FOR TWO DAYS DURING THE WET SEASON ( OCTOBER 1ST THROUGH APRIL 30TH) OR SEVEN DAYS DURING THE DRY SEASON ( MAY 1ST THROUGH SEPTEMBER 30TH) SHALL BE IMMEDIATELY STABILIZED WITH THE APPROVED ESC COVER METHODS ( E.G., SEEDING, MULCHING, PLASTIC COVERING, ETC.) IN CONFORMANCE WITH APPENDIX D OF THE RENTON SWDM. 13.WET SEASON ESC REQUIREMENTS APPLY TO ALL CONSTRUCTION SITES BETWEEN OCTOBER 1ST AND APRIL 30TH, UNLESS OTHERWISE APPROVED BY THE CITY. 14.ANY AREA NEEDING ADDITIONAL ESC MEASURES, NOT REQUIRING IMMEDIATE ATTENTION, SHALL BE ADDRESSED WITHIN SEVEN ( 7) DAYS. 15.THE ESC BMPS ON INACTIVE SITES SHALL BE INSPECTED AND MAINTAINED AT A MINIMUM OF ONCE A MONTH OR WITHIN 24 HOURS FOLLOWING A STORM EVENT. INSPECTION AND MAINTENANCE SHALL OCCUR MORE FREQUENTLY AS REQUIRED BY THE CITY. 16.BEFORE COMMENCEMENT OF ANY CONSTRUCTION ACTIVITY, CATCH BASIN INSERTS PER THE CITY STANDARD PLAN 216. 30 SHALL BE PROVIDED FOR ALL STORM DRAIN INLETS DOWNSLOPE AND WITHIN 500 FEET OF A DISTURBED OR CONSTRUCTION AREA, UNLESS THE RUNOFF THAT ENTERS THE INLET WILL BE CONVEYED TO A SEDIMENT POND OR TRAP. ALL CATCH BASIN INSERTS SHALL BE PERIODICALLY INSPECTED AND REPLACED AS NECESSARY TO ENSURE FULLY FUNCTIONING CONDITION. 17.AT NO TIME SHALL SEDIMENT ACCUMULATION EXCEED 2/3 OF THE CAPACITY OF THE CATCH BASIN SUMP. ALL CATCH BASINS AND CONVEYANCE LINES SHALL BE CLEANED PRIOR TO PAVING. THE CLEANING OPERATION SHALL NOT FLUSH SEDIMENT- LADEN WATER INTO THE DOWNSTREAM SYSTEM. 18.ANY PERMANENT STORMWATER FACILITY LOCATION USED AS A TEMPORARY SETTLING BASIN SHALL BE MODIFIED WITH THE NECESSARY ESC BMPS AND SHALL PROVIDE ADEQUATE STORAGE CAPACITY. IF THE TEMPORARY FACILITY IS TO ULTIMATELY FUNCTION AS AN INFILTRATION SYSTEM IN ITS PERMANENT STATE, THE TEMPORARY FACILITY SHALL BE ROUGH GRADED SO THAT THE BOTTOM AND SIDES ARE AT LEAST THREE FEET ABOVE THE FINAL GRADE OF THE PERMANENT FACILITY. 19.AREAS DESIGNATED ON THE PLAN( S) CONTAINING EXISTING STORMWATER FACILITIES OR ON- SITE BMPS ( AMENDED SOILS, BIORETENTION, PERMEABLE PAVEMENT, ETC.) SHALL BE CLEARLY FENCED AND PROTECTED USING ESC BMPS TO AVOID SEDIMENTATION AND COMPACTION DURING CONSTRUCTION. 20.PRIOR TO THE BEGINNING OF THE WET SEASON ( OCTOBER 1ST), ALL DISTURBED AREAS SHALL BE INSPECTED TO IDENTIFY WHICH ONES SHALL BE SODDED OR SEEDED IN PREPARATION FOR THE WINTER RAINS. DISTURBED AREAS SHALL BE SODDED OR SEEDED WITHIN ONE WEEK OF THE BEGINNING OF THE WET SEASON. AN EXHIBIT OF THOSE AREAS TO BE SODDED OR SEEDED AND THOSE AREAS TO REMAIN UNCOVERED SHALL BE SUBMITTED TO THE CITY FOR REVIEW. 21.PRIOR TO FINAL CONSTRUCTION ACCEPTANCE, THE PROJECT SITE SHALL BE STABILIZED TO PREVENT SEDIMENT- LADEN WATER FROM LEAVING THE PROJECT SITE, ALL ESC BMPS SHALL BE REMOVED, AND STORMWATER CONVEYANCE SYSTEMS, FACILITIES, AND ON- SITE BMPS SHALL BE RESTORED TO THEIR FULLY FUNCTIONING CONDITION. ALL DISTURBED AREAS OF THE PROJECT SITE SHALL BE VEGETATED OR OTHERWISE PERMANENTLY STABILIZED. AT A MINIMUM, DISTURBED AREAS SHALL BE SODDED OR SEEDED AND MULCHED TO ENSURE THAT SUFFICIENT COVER WILL DEVELOP SHORTLY AFTER FINAL APPROVAL. MULCH WITHOUT SEEDING IS ADEQUATE FOR AREAS TO BE LANDSCAPED BEFORE OCTOBER 1ST. 22.ROCKERIES ARE CONSIDERED TO BE A METHOD OF BANK STABILIZATION AND EROSION CONTROL. ROCKERIES SHALL NOT BE CONSTRUCTED TO SERVE AS RETAINING WALLS. ALL ROCKERIES IN CITY ROAD RIGHTS- OF- WAY SHALL BE CONSTRUCTED IN ACCORDANCE WITH CITY STANDARDS. ROCKERIES OUTSIDE OF ROAD RIGHTS- OF- WAY SHALL BE CONSTRUCTED IN ACCORDANCE WITH THE INTERNATIONAL BUILDING CODE. CITY OF RENTON EROSION AND SEDIMENT CONTROL (ESC) STANDARD PLAN NOTES (CITY STANDARD PLAN 268.00) 1.BEFORE ANY CONSTRUCTION ACTIVITY ARRANGE AND ATTEND PRE-CONSTRUCTION CONFERENCES WITH CITY OF RENTON AND JACOBSON CONSULTING ENGINEERS. 2.COMPLY WITH CONSTRUCTION PHASING REQUIREMENTS IDENTIFIED IN DRAWINGS AND SPECIFICATIONS. 3.PROVIDE TEMPORARY AND INTERIM MEASURES REQUIRED FOR EXECUTION OF THE WORK. 4.VERIFY VERTICAL AND HORIZONTAL LOCATIONS OF ALL EXISTING UNDERGROUND UTILITIES. CONTACT ALL UTILITY COMPANIES OR PROVIDERS THAT MAY BE AFFECTED BY THE PROPOSED CONSTRUCTION. CALL 811 AND UTILIZE PRIVATE LOCATING COMPANY ALONG THE ENTIRE WORK AREA. 5.PROVIDE CATCH BASIN PROTECTION AND OTHER APPROPRIATE TESC MEASURES, INCLUDING STRAW WATTLES, ETC. COORDINATE WITH KING COUNTY INSPECTOR. 6.BACKFILL AND COMPACT TRENCH. PATCH AND RESTORE SITE PER PLANS 7.INSTALL ALL NEW PAVING, LANDSCAPING AND SITE STABILIZATION. 8.CONTACT DESIGN ENGINEER AND CITY SO THEY CAN PUNCH LIST THE SITE. ADDRESS PUNCH LIST ITEMS AS REQUIRED. CONSTRUCTION SEQUENCE 1.SCHEDULE MAJOR LAND DISTURBING ACTIVITIES DURING THE DRY MONTHS AND ALLOW TIME BEFORE THE WET SEASON BEGINS TO ADEQUATELY STABILIZE THE DISTURBED GROUND. 2.PHASE AND/OR SCHEDULE CONSTRUCTION TO LIMIT THE AMOUNT OF DISTURBED, UNSTABILIZED SOIL EXPOSED AT ANY ONE TIME. 3.FENCE OR FLAG AREAS TO BE PROTECTED OF LEFT UNDISTURBED DURING CONSTRUCTION, INCLUDING INSTALLATION OF TEMPORARY CONSTRUCTION FENCING. 4.STRIP AND CLEAR AND GRUB FIELD SUFFICIENTLY FOR INSTALLATION OF TEMPORARY EROSION SEDIMENTATION CONTROL (ESC) BMPS. 5.INSTALL TEMPORARY ESC MEASURES INDICATED ON PLANS, INCLUDING SILT FENCE, CATCH BASIN INSERTS, AND STRAW WATTLES. COORDINATE WITH CITY OF RENTON INSPECTOR. 6.BEGIN GRADING AND EXCAVATION FOR FIELD UNDERDRAIN AND IRRIGATION PIPING, AND FOR PAVEMENT SUBGRADES. 7.TEMPORARILY STABILIZE SITE, THROUGH RE-VEGETATION, HYDROSEED, MULCHING OR OTHER APPROPRIATE BMPS AS A RESULT OF SITE GRADING IN AREAS THAT WILL NOT RECEIVE HARDSCAPE. 8.CONSTRUCT STORM AND IRRIGATION UTILITIES, CONCRETE, ASPHALT, AND PERMEABLE PAVEMENTS, AS WELL AS STAIRS, CHEEK WALLS, AND MOW STRIPS FOR FENCING. 9.PLACE FILL SECTION AND LAWN/SEED FOR PLAYFIELD. 10.REMOVE TEMPORARY ESC FACILITIES UPON COMPLETION OF CONSTRUCTION AND ONLY ONCE SITE IS STABILIZED, INSPECTED, AND APPROVED BY CITY OF RENTON INSPECTOR. TESC CONSTRUCTION SEQUENCE 1.BEFORE ANY CONSTRUCTION OR DEVELOPMENT ACTIVITY OCCURS, A PRE- CONSTRUCTION MEETING SHALL BE HELD AMONG THE CITY OF RENTON, HEREBY REFERRED TO AS THE CITY, THE APPLICANT, AND THE APPLICANT' S CONTRACTOR. 2.THE APPLICANT SHALL BE RESPONSIBLE FOR SECURING ALL NECESSARY CITY, STATE, AND FEDERAL PERMITS PRIOR TO CONSTRUCTION. 3.ALL STORM DRAINAGE IMPROVEMENTS SHALL BE DESIGNED AND CONSTRUCTED IN ACCORDANCE WITH THE LATEST EDITION OF THE CITY OF RENTON SURFACE WATER DESIGN MANUAL ( RENTON SWDM), RENTON MUNICIPAL CODE ( RMC), AND THE STANDARD SPECIFICATIONS FOR ROAD, BRIDGE AND MUNICIPAL CONSTRUCTION PREPARED BY WSDOT AND THE AMERICAN PUBLIC WORKS ASSOCIATION ( APWA). IT SHALL BE THE SOLE RESPONSIBILITY OF THE APPLICANT TO CORRECT ANY ERROR, OMISSION OR VARIATION FROM THE ABOVE REQUIREMENTS FOUND IN THE PLANS. ALL CORRECTIONS SHALL BE AT NO ADDITIONAL COST TO THE CITY. 4.APPROVAL OF THE ROAD, GRADING, PARKING, BUILDING, AND DRAINAGE PLAN DOES NOT CONSTITUTE AS APPROVAL OF ANY OTHER CONSTRUCTION ( E.G. WATER, SEWER, GAS, ELECTRICAL. ETC.). PLANS FOR STRUCTURES SUCH AS BRIDGES, VAULTS, AND RETAINING WALLS REQUIRE A SEPARATE REVIEW AND APPROVAL BY THE CITY PRIOR TO CONSTRUCTION. THE SURFACE WATER DRAINAGE SYSTEM SHALL BE CONSTRUCTED ACCORDING TO THE APPROVED PLANS. ANY DEVIATION FROM THE APPROVED PLANS WILL REQUIRE COORDINATION FOLLOWED BY WRITTEN APPROVAL FROM THE CITY. 5.A COPY OF THE APPROVED PLANS SHALL BE ON THE JOB SITE WHENEVER CONSTRUCTION IS IN PROGRESS. 6.HE LOCATIONS OF ALL EXISTING UTILITIES SHOWN HEREON HAVE BEEN ESTABLISHED BY FIELD SURVEY OR OBTAINED FROM AVAILABLE RECORDS AND SHALL THEREFORE BE CONSIDERED APPROXIMATE ONLY AND NOT NECESSARILY COMPLETE. IT IS THE SOLE RESPONSIBILITY OF THE APPLICANT AND THE APPLICANT' S CONTRACTOR TO INDEPENDENTLY VERIFY THE ACCURACY OF ALL UTILITY LOCATIONS SHOWN, AND TO FURTHER DISCOVER AND AVOID ANY OTHER UTILITIES NOT SHOWN HEREON THAT MAY BE AFFECTED BY THE IMPLEMENTATION OF THIS PLAN. THE APPLICANT SHALL RECORD ON THE AS- BUILT DRAWINGS ALL UNDOCUMENTED UTILITIES DISCOVERED AND ANY CHANGES TO THE APPROVED PLANS. THE APPLICANT SHALL IMMEDIATELY NOTIFY THE ENGINEER OF RECORD IF A CONFLICT EXISTS. 7.VERTICAL DATUM SHALL BE NAVD 88 AND HORIZONTAL DATUM SHALL BE NAD 83 ( WA STATE PLANE, NORTH), UNLESS OTHERWISE APPROVED BY THE CITY. REFERENCE BENCHMARK, DATUM, AND ELEVATIONS SHALL BE NOTED ON THE PLANS. 8.ALL UTILITY TRENCH BACKFILL AND ROADWAY SUBGRADE SHALL BE COMPACTED TO 95% MAXIMUM DRY DENSITY PER SECTION 2-03.3(14)D - COMPACTION AND MOISTURE CONTROL TESTS OF THE WSDOT STANDARD SPECIFICATIONS. IN PERMEABLE PAVEMENT AND OTHER INFILTRATION AREAS, ALL TRENCH BACKFILL SHALL BE FIRM AND UNYIELDING BUT IN NO CASE SHALL BE COMPACTED TO MORE THAN 92% OF MAXIMUM DRY DENSITY. 9.OPEN CUTTING OF EXISTING ROADWAYS FOR STORM DRAINAGE WORK IS NOT ALLOWED UNLESS SPECIFICALLY APPROVED BY THE CITY AND NOTED ON THESE APPROVED PLANS. ANY OPEN CUT SHALL BE RESTORED IN ACCORDANCE WITH THE CITY TRENCH RESTORATION STANDARDS. 10.ALL PIPE AND STRUCTURES SHALL BE STAKED FOR SURVEY LINE AND GRADE PRIOR TO THE START OF CONSTRUCTION. WHERE SHOWN ON THE PLANS OR WHERE DIRECTED BY THE CITY, THE EXISTING MANHOLES, CATCH BASINS, OR INLETS SHALL BE ADJUSTED TO THE GRADE AS STAKED. 11.ALL FLOW CONTROL FACILITIES SHALL BE INSTALLED AND IN OPERATION PRIOR TO, OR IN CONJUNCTION WITH, ANY CONSTRUCTION ACTIVITY UNLESS OTHERWISE APPROVED BY THE CITY. 12.ALL PIPE AND APPURTENANCES SHALL BE LAID ON A PROPERLY PREPARED FOUNDATION IN ACCORDANCE WITH THE CURRENT STATE OF WASHINGTON STANDARD SPECIFICATION FOR ROAD AND BRIDGE CONSTRUCTION. THIS SHALL INCLUDE NECESSARY LEVELING OF THE TRENCH BOTTOM OR THE TOP OF THE FOUNDATION MATERIAL, AS WELL AS PLACEMENT AND COMPACTION OF REQUIRED BEDDING MATERIAL TO UNIFORM GRADE SO THAT THE ENTIRE LENGTH OF THE PIPE WILL BE SUPPORTED ON A UNIFORMLY DENSE, UNYIELDING BASE. ALL PIPE BEDDING AND BACKFILL SHALL BE AS SHOWN ON THE CITY STANDARD PLAN 220. 00, 220. 10, AND 220. 20. 13.STEEL PIPE SHALL BE ALUMINIZED, OR GALVANIZED WITH ASPHALT TREATMENT 1, 2, OR 5 INSIDE AND OUTSIDE. 14.ALL DRAINAGE STRUCTURES SUCH AS CATCH BASINS AND MANHOLES SHALL BE FITTED WITH DUCTILE IRON, BOLT- LOCKING LIDS PER THE CITY STANDARD PLAN 204. 10, 204. 20, 204. 30, 204. 40, AND 204. 50. STRUCTURES SHALL HAVE: ·RECTANGULAR OR ROUND, SOLID LIDS WHEN NOT COLLECTING RUNOFF, AND OUTSIDE OF THE ROADWAY. ·ROUND, SOLID LIDS WHEN NOT COLLECTING RUNOFF, AND LOCATED WITHIN THE ROADWAY, BUT OUTSIDE OF THE CURB/ GUTTER LINE. ·ROUND, SOLID LIDS DISPLAYING THE CITY LOGO WHEN WITHIN THE PUBLIC RIGHT- OF- WAY OR IN AN EASEMENT TO THE CITY. PRIVATE STRUCTURE LIDS OUTSIDE PUBLIC RIGHT- OF- WAY AND EASEMENTS TO THE CITY SHALL NOT DISPLAY THE CITY LOGO. 15.BUILDINGS AND OTHER STRUCTURES SHALL BE PLACED IN ACCORDANCE WITH TABLE 4.1 EASEMENT WIDTHS AND BUILDING SETBACKS LINES OF THE RENTON SWDM. 16.LIDS OF MANHOLES/ CATCH BASINS WITHIN PUBLIC RIGHT- OF- WAY SHALL NOT BE ADJUSTED TO FINAL GRADE UNTIL AFTER PAVING. ALL MANHOLE/ CATCH BASIN RIMS SHALL BE ADJUSTED TO BE FLUSH WITH FINAL FINISHED GRADES, UNLESS OTHERWISE SHOWN. 17.ALL DRIVEWAY CULVERTS LOCATED WITHIN CITY RIGHT- OF- WAY SHALL BE OF SUFFICIENT LENGTH TO PROVIDE A MINIMUM 3:1 SLOPE FROM THE EDGE OF THE DRIVEWAY TO THE BOTTOM OF THE DITCH. 18.ROCK FOR EROSION PROTECTION OF ROADSIDE DITCHES, WHERE REQUIRED, SHALL BE OF SOUND QUARRY ROCK PLACED TO A MINIMUM DEPTH OF ONE ( 1) FOOT AND SHALL MEET THE FOLLOWING SPECIFICATIONS: ·4 - 8 INCH ROCK / 40 - 70% PASSING; ·2 - 4 INCH ROCK / 30 - 40% PASSING; AND ·LESS THAN 2 INCH ROCK / 10 - 20% PASSING. 19.FOOTING DRAINAGE SYSTEMS AND ROOF DOWNSPOUT SYSTEMS SHALL NOT BE INTERCONNECTED AND SHALL SEPARATELY CONVEY COLLECTED FLOWS TO THE CONVEYANCE SYSTEM OR FLOW CONTROL FACILITY ON THE SITE, UNLESS APPROVED BY THE CITY. FOOTING DRAINS SHALL NOT BE CONNECTED TO ON- SITE BMPS. 20.THE END OF EACH STORM DRAIN STUB SHALL BE CAPPED. A CLEANOUT TOPPED WITH A BOLT- LOCKING LID MARKED " STORM” OR " DRAIN" SHALL BE LOCATED AT THE PROPERTY LINE OR AT THE POINT OF CONNECTION OF A PRIVATE STORM DRAINAGE CONVEYANCE SYSTEM PER THE CITY STANDARD PLAN 227. 00. 21.ALL STORM SYSTEM EXTENSIONS SHALL BE STAKED FOR LINE AND GRADE BY A SURVEYOR LICENSED IN WASHINGTON STATE, AND CUT SHEETS SHALL BE PROVIDED TO THE CITY PRIOR TO CONSTRUCTION. 22.ALL NEWLY- INSTALLED AND NEWLY- REHABILITATED ( PUBLIC AND PRIVATE) STORM CONVEYANCE SYSTEMS SHALL BE INSPECTED BY MEANS OF REMOTE CCTV ACCORDING TO THE CITY STANDARD PLAN 266. 00. CCTV INSPECTIONS AND REPORTS SHALL BE SUBMITTED TO THE CITY PRIOR TO RECEIVING APPROVAL TO INSTALL PROJECT CURBS, GUTTERS AND/ OR PAVEMENT. 23.ALL STORM SYSTEMS AND CONNECTIONS TO EXISTING MAINS SHALL BE TESTED IN ACCORDANCE WITH SECTION 7-04.3(1) OF THE WSDOT STANDARD SPECIFICATIONS AND IN THE PRESENCE OF A REPRESENTATIVE OF THE CITY. STORM DRAIN STUBS SHALL BE TESTED FOR ACCEPTANCE AT THE SAME TIME THE MAIN STORM IS TESTED. 24.FOR ALL DISTURBED PERVIOUS AREAS ( COMPACTED, GRADED, LANDSCAPED, ETC.) OF THE DEVELOPMENT SITE, TO MAINTAIN THE MOISTURE CAPACITY OF THE SOIL EITHER STOCKPILE AND REDISTRIBUTE THE EXISTING DUFF LAYER AND NATIVE TOPSOIL OR AMEND THE SOIL WITH COMPOST IN ACCORDANCE WITH STANDARD PLAN 264. 00. 25.ISSUANCE OF THE BUILDING OR CONSTRUCTION PERMITS BY THE CITY DOES NOT RELIEVE THE APPLICANT OF THE CONTINUING LEGAL OBLIGATION AND/ OR LIABILITY CONNECTED WITH STORMWATER DISPOSAL. THE CITY DOES NOT ACCEPT ANY OBLIGATION FOR THE PROPER FUNCTIONING AND MAINTENANCE OF THE STORM SYSTEM PROVIDED DURING CONSTRUCTION. 26.ADEQUATE SAFEGUARDS, SAFETY DEVICES, PROTECTIVE EQUIPMENT, FLAGGERS, AND ANY OTHER ACTIONS NEEDED TO PROTECT THE LIFE, HEALTH, AND SAFETY OF THE PUBLIC, AND TO PROTECT PROPERTY IN CONNECTION WITH THE PERFORMANCE OF WORK SHALL BE PROVIDED. ANY WORK WITHIN THE TRAVELED RIGHT- OF- WAY THAT MAY INTERRUPT NORMAL TRAFFIC FLOW SHALL REQUIRE A TRAFFIC CONTROL PLAN APPROVED BY THE CITY. ALL SECTIONS OF THE WSDOT STANDARD SPECIFICATIONS 1-10 TEMPORARY TRAFFIC CONTROL SHALL APPLY. 27.PROJECTS LOCATED WITHIN THE CITY' S AQUIFER PROTECTION AREA ( APA) SHALL COMPLY WITH SPECIAL REQUIREMENT # 6 OF THE RENTON SWDM AND AQUIFER PROTECTION REGULATIONS ( RMC 4-3-050). 28.PLACEMENT OF SURFACE APPURTENANCES ( CATCH BASIN/ MANHOLE LIDS, CLEANOUTS, INLETS, ETC.) IN THE STREET TRAVEL LANE WHEEL PATH, INTERSECTIONS OF STREET TRAVEL LANES, BIKE LANES, SIDEWALKS, AND CROSSWALKS SHALL BE AVOIDED WHENEVER POSSIBLE. ANY SURFACE APPURTENANCE PLACED IN A SIDEWALK OR CROSSWALK SHALL BE FITTED WITH A NON- SLIP OR NON- SKID LID PER ADA REQUIREMENTS. 29.CLEARLY LABEL PUBLIC AND PRIVATE SYSTEMS ON THE PLANS. PRIVATE SYSTEMS SHALL BE MAINTAINED BY THE APPLICANT. 30.MINIMUM COVER OVER STORM DRAINAGE PIPE SHALL CONFORM TO TABLE 4.2.1.A2 OF THE RENTON SWDM. 31.CONSTRUCTED PERMEABLE PAVEMENT SHALL BE PERMEABLE ENOUGH TO ABSORB WATER AT A MINIMUM RATE OF 20 INCHES PER HOUR IMMEDIATELY AFTER THE PAVEMENT SURFACE HAS BEEN WETTED CONTINUOUSLY FOR AT LEAST 10 MINUTES. COMPLIANCE WITH THIS MINIMUM RATE SHALL BE CHECKED PRIOR TO CONSTRUCTION APPROVAL OF THE PAVEMENT. COMPLIANCE MAY BE CHECKED USING A SIMPLE BUCKET TEST IN WHICH 5 GALLONS OF WATER IS POURED ONTO THE PAVEMENT SURFACE ALL AT ONCE. IF ONLY A MINOR AMOUNT OF WATER PONDS OR RUNS OFF THE SURFACE, THEN THE PAVEMENT IS CONSIDERED TO MEET THE MINIMUM RATE OF ABSORPTION. AT LEAST ONE TEST SHALL BE CONDUCTED PER 1,000 SQUARE FEET OF PERMEABLE PAVEMENT. IF THIS TEST IS NOT CONCLUSIVE, THEN ANOTHER TEST PER ASTM C1701 SHALL BE CONDUCTED. FOR LARGE AREAS ( E.G., PARKING AREAS), TESTING OBSERVATION MAY BE ACCOMPLISHED WHILE WALKING BEHIND A SLOWLY MOVING WATER TRUCK DISCHARGING WATER AT A RATE SIMILAR TO THE BUCKET TEST. PERMEABLE PAVERS SHALL BE TESTED USING ASTM C1781. CITY OF RENTON SURFACE WATER STANDARD PLAN NOTES (CITY STANDARD PLANS 267.00 & 267.10) LINDBERGH HIGH SCHOOL FIELD IMPROVEMENTS NOTES SHEET R-434402 CIVIL CONSTRUCTION PERMIT CIVIL CONSTRUCTION PERMIT RESUBMITTAL CIVIL CONSTRUCTION PERMIT RESUBMITTAL 2/21/25 4/14/25 6/06/25 DEVELOPMENT ENGINEERING HBray 06/24/2025 405 404.5 404 403.5 43 0 42 9 . 5 429 12 8 T H A V E N U E S E SE 166TH STREET SE 167TH STREET SE 168TH STREET 12 8 T H A V E N U E S E SE 166TH PLACE 13 2 N D P L A C E S E 13 2 N D P L A C E S E SD SD CITY OF RENTON IN COMPLIANCE WITH CITY OF RENTON STANDARDS TE D - 4 0 - 4 3 4 4 43667 NSTATE O F WASHI N G T ON R EGIST E R E D P R O F E SSIONAL E N G IN EER O S B O CAJA.DLAREJ LU A 2 5 - 0 0 0 0 5 1 PR 2 5 - 0 0 0 0 1 8 C2 5 0 0 0 9 7 7 ACW JAJ ACW JAJ ACW JAJ SCALE 1"=80' 40 80 1600 g. 8-1-1 Call before you D or 1-800-424-5555 UNDERGROUND SERVICE (USA) R 1"=80' C X 0 1 CX02 LINDBERGH HIGH SCHOOL FIELD IMPROVEMENTS OVERALL SITE PLAN CONTRACTOR STAGING AND LAYDOWN AREAS CONTRACTOR STAGING AND LAYDOWN AREAS R-434403 CIVIL CONSTRUCTION PERMIT CIVIL CONSTRUCTION PERMIT RESUBMITTAL CIVIL CONSTRUCTION PERMIT RESUBMITTAL 2/21/25 4/14/25 6/06/25 DEVELOPMENT ENGINEERING HBray 06/24/2025 405 404.5 404 403.5 4 3 0 4 2 9 . 5 429 12 8 T H A V E N U E S E SE 166TH STREET SE 167TH STREET SD SD SD SD SD SD S D S D SD CITY OF RENTON IN COMPLIANCE WITH CITY OF RENTON STANDARDS TE D - 4 0 - 4 3 4 4 43667 NSTATE O F WASHI N G T ON R EGIST E R E D P R O F E SSIONAL E N G IN EER O S B O CAJA.DLAREJ LU A 2 5 - 0 0 0 0 5 1 PR 2 5 - 0 0 0 0 1 8 C2 5 0 0 0 9 7 7 ACW JAJ ACW JAJ ACW JAJ SCALE 1"=40' 20 40 800 g. 8-1-1 Call before you D or 1-800-424-5555 UNDERGROUND SERVICE (USA) R 1"=40'LINDBERGH HIGH SCHOOL FIELD IMPROVEMENTS PROJECT AREA OVERALL CONTRACTOR STAGING AND LAYDOWN AREAS R-434404 CIVIL CONSTRUCTION PERMIT CIVIL CONSTRUCTION PERMIT RESUBMITTAL CIVIL CONSTRUCTION PERMIT RESUBMITTAL 2/21/25 4/14/25 6/06/25 DEVELOPMENT ENGINEERING HBray 06/24/2025 0+00 1+00 2+00 3+00 4+00 5+00 6+00 7+00 0+50 1+50 2+50 3+50 4+50 5+50 6+50 128TH AVENUE SE SE 1 6 6 T H ST R E E T SE 1 6 7 T H ST R E E T ST A 2 + 2 2 . 5 9 . 8 6 ' L ST A 3 + 2 2 . 5 9 . 6 0 ' L ST A 4 + 2 2 . 6 9 . 5 0 ' L ST A 5 + 2 2 . 6 9 . 3 8 ' L ST A 6 + 2 2 . 6 9 . 2 0 ' L ST A 7 + 2 2 . 6 9 . 0 8 ' L BICYCLE SHARROW (TYP OF 11) 100' SPACING SEE DETAIL C213 4 8+00 9+00 10+00 11+00 12+00 13+00 14+00 14+96 8+50 9+50 10+50 11+50 12+50 13+50 14+50 ST R E E T 128TH AVENUE SE 128TH AVENUE SE SE 1 6 8 T H ST R E E T SE 1 6 7 T H ST R E E T ST A 8 + 2 2 . 6 9 . 0 7 ' L ST A 9 + 2 2 . 6 9 . 2 5 ' L ST A 1 0 + 2 2 . 6 9 . 0 3 ' L ST A 1 1 + 2 2 . 6 8 . 0 3 ' L ST A 1 2 + 2 2 . 6 7 . 9 9 ' L BICYCLE SHARROW (TYP OF 11) 100' SPACING SEE DETAIL C213 4 CITY OF RENTON IN COMPLIANCE WITH CITY OF RENTON STANDARDS TE D - 4 0 - 4 3 4 4 43667 NSTATE O F WASHI N G T ON R EGIST E R E D P R O F E SSIONAL E N G IN EER O S B O CAJA.DLAREJ LU A 2 5 - 0 0 0 0 5 1 PR 2 5 - 0 0 0 0 1 8 C2 5 0 0 0 9 7 7 ACW JAJ ACW JAJ ACW JAJ SCALE 1"=30' 15 30 600 g. 8-1-1 Call before you D or 1-800-424-5555 UNDERGROUND SERVICE (USA) R 1"=30'LINDBERGH HIGH SCHOOL FIELD IMPROVEMENTS PAVEMENT MARKINGS PLAN R-434405 CIVIL CONSTRUCTION PERMIT CIVIL CONSTRUCTION PERMIT RESUBMITTAL CIVIL CONSTRUCTION PERMIT RESUBMITTAL 2/21/25 4/14/25 6/06/25 MA T C H L I N E 7 + 5 0 S E E B O T T O M L E F T MA T C H L I N E 7 + 5 0 S E E T O P R I G H T DEVELOPMENT ENGINEERING HBray 06/24/2025 1 2 8 T H A V E N U E S E IP IP IP IP IP IP IP IP IP IPIP IP IP IP IP IP VEG CONTRACTOR TO PROTECT EXISTING ELECTRICAL VAULT IS PUMP "CLEAN" STORMWATER FROM TEMP SEDIMENT SETTLEMENT TANKS TO EXISTING CATCH BASIN. CONTRACTOR TO ENSURE ALL DISCHARGE MEETS TURBIDITY AND NPDES REQUIREMENTS. (2) 21,000 & (1) 8,400 GALLON CAPACITY TEMPORARY SEDIMENT SETTLEMENT TANKS ("BAKER TANK" OR APPROVED EQUAL). CONTRACTOR SHALL PROVIDE ALL PUMPS REQUIRED TO MANAGE CONSTRUCTION STORMWATER AND DISCHARGE AT THE SITE. SUMP AND PUMP INSTALLED AT LOW POINT SEE DETAIL IS IS INTERCEPTOR SWALE WITH ROCK CHECK DAMS AT 50' O.C. SPACING SEE DETAILS SF SF SF INLET PROTECTION (TYP) SEE DETAIL C110 4 SILT FENCE (TYP) SEE DETAIL C110 2 CE STABILIZED CONSTRUCTION ENTRANCE (TYP) SEE DETAIL C110 3 15 ' IP IP IP C110 1 C110 8 C110 5 SAVE AND PROTECT EX 8" WATER SAVE AND PROTECT EX RETAINING WALL IP TREE PROTECTION FENCING SEE DETAIL C110 7 REMOVE EX DUGOUT AND APPURTENANCES REMOVE EX DUGOUT AND APPURTENANCES APPROXIMATE OUTLINE OF STORMTECH CHAMBER EXCAVATION SAWCUT AND REMOVE AND REPLACE CONCRETE AND ASPHALT FOR UTILITY TRENCHING CONTRACTOR STAGING AND LAYDOWN AREA CF CONSTRUCTION FENCE SEE DETAIL C110 6 TEMPORARY FORCE MAIN PUMP TO SEDIMENT SETTLING TANKS SD TEMPORARY STORM PIPE CULVERT INSTALL INLET PROTECTION ON CATCH BASINS IMMEDIATELY DOWNSTREAM AND UP TO 500 FEET FROM PROJECT DISTURBANCE AREA SEE DETAIL C110 4 REMOVE EX CONCRETE SIGN BASE SAWCUT AND REMOVE EX CONCRETE PAVEMENT (TYP) SAVE AND PROTECT EX ELEC/COMM CITY OF RENTON IN COMPLIANCE WITH CITY OF RENTON STANDARDS TE D - 4 0 - 4 3 4 4 43667 NSTATE O F WASHI N G T ON R EGIST E R E D P R O F E SSIONAL E N G IN EER O S B O CAJA.DLAREJ LU A 2 5 - 0 0 0 0 5 1 PR 2 5 - 0 0 0 0 1 8 C2 5 0 0 0 9 7 7 ACW JAJ ACW JAJ ACW JAJ SCALE 1"=20' 0 10 20 40 g. 8-1-1 Call before you D or 1-800-424-5555 UNDERGROUND SERVICE (USA) R 1"=20' LEGEND TEMP CONSTRUCTION ENTRANCE TREE PROTECTION INLET PROTECTION PROPERTY LINE INTERCEPTOR SWALE SILT FENCE TEMP CONSTRUCTION FENCING TEMP CONSTRUCTION GATE IS SF CF CG IP VEG CE TEMP SUMP AND PUMP MAT C H L I N E - S E E S H E E T C10 2 REMOVE CONCRETE PAVEMENT DEMO SUBDRAINAGE LINDBERGH HIGH SCHOOL FIELD IMPROVEMENTS DEMOLITION AND TESC PLAN NORTH R-434406 CIVIL CONSTRUCTION PERMIT CIVIL CONSTRUCTION PERMIT RESUBMITTAL CIVIL CONSTRUCTION PERMIT RESUBMITTAL 2/21/25 4/14/25 6/06/25 REMOVE ASPHALT PAVEMENT SAWCUT LINE TEMPORARY STORM PIPE SD DEVELOPMENT ENGINEERING HBray 06/24/2025 SE 167TH STREET 12 8 T H A V E N U E S E IPINLET PROTECTION (TYP) SEE DETAIL C110 4 IP VEG IP SUMP AND PUMP INSTALLED AT LOW POINT ON-SITE. SEE DETAIL SF IS SF IS SF SF SILT FENCE (TYP) SEE DETAIL C110 2 INTERCEPTOR SWALE WITH ROCK CHECK DAMS AT 50' O.C. SPACING SEE DETAILS (1) 18,900 & (1) 8,400 GALLON CAPACITY TEMPORARY SEDIMENT SETTLEMENT TANKS ("BAKER TANK" OR APPROVED EQUAL). CONTRACTOR SHALL PROVIDE ALL PUMPS REQUIRED TO MANAGE CONSTRUCTION STORMWATER AND DISCHARGE AT THE SITE. PUMP "CLEAN" STORMWATER FROM TEMP SEDIMENT SETTLEMENT TANKS TO EXISTING CATCH BASIN. CONTRACTOR TO ENSURE ALL DISCHARGE MEETS TURBIDITY AND NPDES REQUIREMENTS. CE STABILIZED CONSTRUCTION ENTRANCE (TYP) SEE DETAIL C110 3 15' C110 5 C110 1 C110 8 IP IP IP IP IP IPIP IP IP IP IP IP IP IP IP IP TREE PROTECTION FENCING C110 7 SALVAGE EX BLEACHERS TO OWNER COORDINATE FOR RELOCATION REMOVE EX DUGOUT AND APPURTENANCES REMOVE EX DUGOUT AND APPURTENANCES IP IP CONTRACTOR TO REMOVE AND REINSTALL FENCING TO MATCH EXISTING CONDITIONS AS REQUIRED TO ACCESS THE FIELD TEMPORARY FORCE MAIN PUMP TO SEDIMENT SETTLING TANKS SAWCUT AND REMOVE EX CONCRETE PAVEMENT (TYP) SAWCUT AND REMOVE EX CONCRETE PAVEMENT (TYP) IP IP SAVE AND PROTECT EXISTING IRRIGATION VAULT TO REMAIN CITY OF RENTON IN COMPLIANCE WITH CITY OF RENTON STANDARDS TE D - 4 0 - 4 3 4 4 43667 NSTATE O F WASHI N G T ON R EGIST E R E D P R O F E SSIONAL E N G IN EER O S B O CAJA.DLAREJ LU A 2 5 - 0 0 0 0 5 1 PR 2 5 - 0 0 0 0 1 8 C2 5 0 0 0 9 7 7 ACW JAJ ACW JAJ ACW JAJ SCALE 1"=20' 0 10 20 40 g. 8-1-1 Call before you D or 1-800-424-5555 UNDERGROUND SERVICE (USA) R 1"=20' M A T C H L I N E - S E E S H E E T C 1 0 1 LEGEND TEMP CONSTRUCTION ENTRANCE TREE PROTECTION INLET PROTECTION PROPERTY LINE INTERCEPTOR SWALE SILT FENCE TEMP CONSTRUCTION FENCING TEMP CONSTRUCTION GATE IS SF CF CG IP VEG CE INSTALL INLET PROTECTION FOR ALL STORM DRAIN STRUCTURES DOWNSTREAM WITHIN 500 FEET OF PROJECT DISTURBANCE AREA TEMP SUMP AND PUMP REMOVE CONCRETE PAVEMENT LINDBERGH HIGH SCHOOL FIELD IMPROVEMENTS DEMOLITION AND TESC PLAN SOUTH R-434407 CIVIL CONSTRUCTION PERMIT CIVIL CONSTRUCTION PERMIT RESUBMITTAL CIVIL CONSTRUCTION PERMIT RESUBMITTAL 2/21/25 4/14/25 6/06/25 DEVELOPMENT ENGINEERING HBray 06/24/2025 CITY OF RENTON IN COMPLIANCE WITH CITY OF RENTON STANDARDS TE D - 4 0 - 4 3 4 4 43667 NSTATE O F WASHI N G T ON R EGIST E R E D P R O F E SSIONAL E N G IN EER O S B O CAJA.DLAREJ LU A 2 5 - 0 0 0 0 5 1 PR 2 5 - 0 0 0 0 1 8 C2 5 0 0 0 9 7 7 ACW JAJ ACW JAJ ACW JAJ 1"=20' Silt Fence 2NTS Stabilized Construction Entrance 3NTS Inlet Protection 4NTS Tree Protection 7NTS 6"=12" PERFORATE PIPE AS NECESSARY 1' TOP OF PIPE SHALL BE 6" MIN ABOVE GRADE PROVIDE SOLID COVER DISCHARGE TO SEDIMENT POND VIA TEMP FORCE MAIN 5% 30 " M I N RUNOFF WITH SEDIMENT FILTERED RUNOFF WATER LEVEL CONCRETE BLOCKS SUMP PUMP AND MOTOR WIRE TIES 24"-36" PVC OR HDPE PIPE W/ 2" DIA WEEP HOLES OR APPROVED EQUAL WRAP WITH PERMEABLE FILTER FABRIC PROVIDE 12" MIN WASHED ROCK AROUND PERIMETER OF PIPE Temporary Sump and Pump 5NTS Interceptor Swale 1NTS 6" MIN. ROCK MUST COMPLETELY COVER THE BOTTOM AND SIDES OF THE DITCH 24" MIN. 2H:1V SLOPES L 2"- 4" ROCKBA L=THE DISTANCE SUCH THAT POINTS A AND B ARE OF EQUAL ELEVATION CROSS SECTION CHECK DAM SPACING Check Dam 8NTS LINDBERGH HIGH SCHOOL FIELD IMPROVEMENTS TESC DETAILS 6' F E N C E LINE POST (TYP) 2.375 INCH 0.D. TOP RAIL 1.666 INCH O.D. STRETCHER BAR BRACE RAIL AND CABLE 1.666 INCH O.D. TRUSS ROD 3/8" DIA W/ TENSION DEVICE TENSION WIRE CONCRETE BLOCK STD WGT GALVANIZED CORNER POST 5/8" WIRE ROPE PROVIDE SECURE END ATTACHMENT AT CORNER AND GATE POSTS AND PROVIDE RUNNING ATTACHMENT AT LINE POSTS AND NEAR CENTER OF EACH FENCE PANEL Construction Fencing 6NTS R-434408 CIVIL CONSTRUCTION PERMIT CIVIL CONSTRUCTION PERMIT RESUBMITTAL CIVIL CONSTRUCTION PERMIT RESUBMITTAL 2/21/25 4/14/25 6/06/25 DEVELOPMENT ENGINEERING HBray 06/24/2025 1 2 8 T H A V E N U E S E 405 404 . 5 404 403 . 5 S D S D S D S D S D S D SD SD SD SD S D SD S D SD SD SDSDSD SD SD SD CUT, CAP, AND ABANDON EX 6" SD C210 8 C210 2 396.87 (EX) 396.90 (EX) TW 398.28 TP 396.97 TW 398.61 TP 397.27 405.36 (EX) 405.28 (EX) 405.35 (EX) 405.42 (EX) 405.33 (EX) 401.72401.77 405.23 (EX) SD A2 CB TYPE I W/ ADA COMPLIANT GRATE RIM 405.30 IE 401.90 12"(IN)SE IE 401.90 12"(OUT)NE SEE DETAIL 8 LF 12" SD @ 0.9% SD A9 SDMH - 54" FLOW CONTROL STRUCTURE RIM 403.53 IE 396.00 12"(IN)NW IE 396.00 12"(OUT)SE SEE DETAIL SD A10 MODULAR WETLAND WATER QUALITY RIM 402.05 IE 395.53 12"(IN)NW IE 392.28 12"(OUT)SE SEE DETAIL 4 LF 12" SD @ 10.5% CONNECT TO EX CATCH BASIN IE 389.15 12"(IN)NW CONTRACTOR TO CONFIRM IE PRIOR TO INSTALLATION. FOR PIPE CONNECTION LAYOUT SEE DETAIL 405.35 (EX) 2. 2 % CONTRACTOR TO POTHOLE AND CONFIRM ELEC/COMM LOCATION PRIOR TO ANY INSTALLATION OF STORM SYSTEM TW 405.00 BW 405.00 TW 405.00 BW 402.75 SEE F-SERIES PLANS FOR FIELD PLANS AND RELATED ACCESSORIES ADS MC-7200 STORMTECH CHAMBER DETENTION SYSTEM LIVE STORAGE VOLUME= 73,339 CF 279 CHAMBERS AND 28 END CAPS IN 14 ROWS 9" GRAVEL BASE, 12" GRAVEL PERIMETER, AND 12" GRAVEL COVER SEE DETAILS CONNECT EX COLLECTOR LINE INSERTA TEE SIDE INLET CONNECTION IE 396.67 (6") SEE DETAIL C211 2 STORMTECH ISOLATOR ROW SEE DETAIL 12 2 L F 1 2 " S D @ 1 . 5 % SD A3 30" NYLOPLAST BASIN W/ TURF COVER RIM 405.34 IE 400.05 12"(IN)SW IE 396.08 8"(BIDIRECTIONAL)N IE 399.38 8"(BIDIRECTIONAL)E SEE DETAILS C210 5 C211 1 SD A4 30" NYLOPLAST BASIN W/ TURF COVER RIM 404.82 IE 399.38 8"(BIDIRECTIONAL)NE IE 396.08 8"(BIDIRECTIONAL)N IE 399.38 8"(BIDIRECTIONAL)SW SEE DETAILS C210 5 C211 1 SD A8 30" NYLOPLAST BASIN W/ TURF COVER RIM 404.07 IE 396.08 8"(BIDIRECTIONAL)N IE 399.38 8"(BIDIRECTIONAL)SW IE 396.08 12"(OUT)SE SEE DETAILS C210 5 C211 1 SD A7 30" NYLOPLAST BASIN W/ TURF COVER RIM 403.91 IE 399.38 8"(BIDIRECTIONAL)NW IE 396.08 8"(BIDIRECTIONAL)S SEE DETAILS C210 5 C211 1 13 LF 12" SD @ 0.6% SD A6 30" NYLOPLAST BASIN W/ TURF COVER RIM 403.79 IE 399.38 8"(BIDIRECTIONAL)NW IE 399.38 8"(BIDIRECTIONAL)SE IE 396.08 8"(BIDIRECTIONAL)S SEE DETAILS SD A5 30" NYLOPLAST BASIN W/ TURF COVER RIM 403.91 IE 396.08 8"(BIDIRECTIONAL)S IE 399.38 8"(BIDIRECTIONAL)E SEE DETAILS C210 5 C211 1 C210 5 C211 1 48 LF 12" SD @ 6.5% 405.37 (EX)405.35 (EX) 405.38 (EX)405.40 (EX) 405.23 (EX) C213 2 C212 1 C212 2 C213 1 STORMTECH BOTTOM CONNECTION (TYP OF 6 ENDCAP CONNECTIONS) SEE DETAIL C213 3 CONNECT TO EX CB IE 402.02 12"(OUT)N SD A1 CB TYPE I RIM 405.26 IE 401.98 12"(IN)S IE 401.98 12"(OUT)NW INSTALL AS CLOSE TO EX CB AS POSSIBLE 3 LF 12" SD @ 1.3% 5. 0 % C210 3 C220 A STORM PROFILE STORM PROFILE C221 B LANDSCAPE BLOCK WALL SEE DETAIL C213 5 C211 4 SEE RETAINING WALL DETAIL 5 ON SHEET F240 X-ING IE 402.10 (EX 4" PERF SD) TP 400.44 (EX 6" SD) X-ING IE 401.78 (EX 4" PERF SD) TP 400.10 (EX 6" SD) X-ING IE 401.60 (EX 4" PERF SD) TP 399.75 (EX 6" SD) X-ING IE 401.67 (EX 4" PERF SD) TP 399.40 (EX 6" SD) 404.94 7. 8 % 8.0 % 401.64 401.69 399.24 399.29 399.17399.22 397.04 397.09 404.19404.25 404.12404.18 8.0 % 8. 0 % 396.95 (EX) SEE HANDRAIL DETAIL ON SHEET F270 (TYP) MATCH EXISTING GRADE AT PAVEMENT JOINT CITY OF RENTON IN COMPLIANCE WITH CITY OF RENTON STANDARDS TE D - 4 0 - 4 3 4 4 43667 NSTATE O F WASHI N G T ON R EGIST E R E D P R O F E SSIONAL E N G IN EER O S B O CAJA.DLAREJ LU A 2 5 - 0 0 0 0 5 1 PR 2 5 - 0 0 0 0 1 8 C2 5 0 0 0 9 7 7 ACW JAJ ACW JAJ ACW JAJ SCALE 1"=20' 0 10 20 40 g. 8-1-1 Call before you D or 1-800-424-5555 UNDERGROUND SERVICE (USA) R LINDBERGH HIGH SCHOOL FIELD IMPROVEMENTS GRADING AND DRAINAGE PLAN NORTH 1"=20' MAT C H L I N E - S E E S H E E T C20 2 LEGEND PROPERTY LINE SYNTHETIC TURF CONCRETE PAVEMENT CANOPY CONTOUR (INDEX) CONTOUR SPOT ELEVATION 110 109.36 109 TC 109.86 BC 109.36 STORM DRAINAGE PIPE SD CB2/CB/NYLOPLAST/CO NOTE:BACKFILL CHAMBER AGGREGATE TO FIELD SUBGRADE (1.0' BELOW FINISH GRADE) STORMTECH DETENTION SYSTEM ASPHALT PAVEMENT R-434409 CIVIL CONSTRUCTION PERMIT CIVIL CONSTRUCTION PERMIT RESUBMITTAL CIVIL CONSTRUCTION PERMIT RESUBMITTAL 2/21/25 4/14/25 6/06/25 DEVELOPMENT ENGINEERING HBray 06/24/2025 Surface Water Enginering jfarah 06/24/2025 SE 167TH STREET 12 8 T H A V E N U E S E 4 3 0 4 2 9 . 5 429 SD SD SD SD SD 41 5 41 3 41 4 41 6 41 7 41 8 41 9 42 0 4 2 1 4 2 3 42 4 429.65 429.38 429.52 (EX)429.78 (EX) 430.45 (EX) 430.41 (EX) 430.22 (EX) 430.14 (EX) 405.35 (EX) 405.36 (EX) 405.28 (EX) 405.42 (EX) 405.33 (EX) 428.66 (EX) 428.64 (EX) 427.95 (EX) 427.80 (EX) 430.42 430.49 430.70 SD A2 CB TYPE I W/ ADA COMPLIANT GRATE RIM 405.30 IE 401.90 12"(IN)SE IE 401.90 12"(OUT)NE SEE DETAIL 8 LF 12" SD @ 0.9% 405.35 (EX) 405.23 (EX) 2.2 % 412.57 (EX) 412.51 (EX) 412.56 (EX) 412.57 (EX) 411.69 412.38 412.47 412.47 415.67 415.67 421.78 421.78 424.88 424.88 428.08 428.08 428.05 428.00 428.02 430.57 (EX) 430.64 (EX) 430.75 (EX) 430.70 (EX) TW 430.73 TW 430.66 430.58 GRADING FOR NEW STAIRS SEE F-SERIES DRAWINGS FOR STAIR DETAILS SEE F-SERIES PLANS FOR FIELD PLANS AND RELATED ACCESSORIES 122 L F 1 2 " S D @ 1 . 5 % TW 405.00 BW 405.00 TW 405.00 BW 402.75 SEE F-SERIES PLANS FOR FIELD PLANS AND RELATED ACCESSORIES 430.86 (EX) 430.72 (EX) BW 429.44 BW 430.47 425.07 425.07 421.87 421.87 418.77 418.77 418.68 418.68 415.48 415.48 CONNECT TO EX CB IE 402.02 12"(OUT)N 3 LF 12" SD @ 1.3% SD A1 CB TYPE I RIM 405.26 IE 401.98 12"(IN)S IE 401.98 12"(OUT)NW INSTALL AS CLOSE TO EX CB AS POSSIBLE C210 3 428.43428.62 428.09 428.291. 8 % 1. 5 % 0.7% 1. 4 % 1.3% 1.8% 1.8%412 C221 B STORM PROFILE C221 B STORM PROFILE C221 B STORM PROFILE SEE RETAINING WALL DETAIL 5 ON SHEET F240 404.94 5.0% 7.8 % 8.0% 8.0% 8.0% 399.17 399.22 399.29 399.24 401.69 401.64 401.77 401.72 404.12 404.19 404.25 404.18 405 404 403 400 401 402 403 404 CITY OF RENTON IN COMPLIANCE WITH CITY OF RENTON STANDARDS TE D - 4 0 - 4 3 4 4 43667 NSTATE O F WASHI N G T ON R EGIST E R E D P R O F E SSIONAL E N G IN EER O S B O CAJA.DLAREJ LU A 2 5 - 0 0 0 0 5 1 PR 2 5 - 0 0 0 0 1 8 C2 5 0 0 0 9 7 7 ACW JAJ ACW JAJ ACW JAJ SCALE 1"=20' 0 10 20 40 g. 8-1-1 Call before you D or 1-800-424-5555 UNDERGROUND SERVICE (USA) R 1"=20' LEGEND M A T C H L I N E - S E E S H E E T C 2 0 1 PROPERTY LINE SYNTHETIC TURF CONCRETE PAVEMENT CANOPY CONTOUR (INDEX) CONTOUR SPOT ELEVATION 110 109.36 109 TC 109.86 BC 109.36 STORM DRAINAGE PIPE SD CB2/CB/CO LINDBERGH HIGH SCHOOL FIELD IMPROVEMENTS GRADING AND DRAINAGE PLAN SOUTH SYNTHETIC TURF R-434410 CIVIL CONSTRUCTION PERMIT CIVIL CONSTRUCTION PERMIT RESUBMITTAL CIVIL CONSTRUCTION PERMIT RESUBMITTAL 2/21/25 4/14/25 6/06/25 DEVELOPMENT ENGINEERING HBray 06/24/2025 Surface Water Enginering jfarah 06/24/2025 CITY OF RENTON IN COMPLIANCE WITH CITY OF RENTON STANDARDS TE D - 4 0 - 4 3 4 4 43667 NSTATE O F WASHI N G T ON R EGIST E R E D P R O F E SSIONAL E N G IN EER O S B O CAJA.DLAREJ LU A 2 5 - 0 0 0 0 5 1 PR 2 5 - 0 0 0 0 1 8 C2 5 0 0 0 9 7 7 ACW JAJ ACW JAJ ACW JAJ Flow Control Structure 8NTS ROOF DOWNSPOUT, SEE ARCHITECTURAL FOR SIZE, FINISH AND DETAILS PAINT ABOVE GRADE PVC PIPE TO MATCH DS. ARCHITECT TO REVIEW COLOR FINISH GRADE 6" CLEANOUT WITH THREADED PLUG. INSTALL CLEANOUT PARALLEL TO THE FACE OF THE BUILDING 6" PVC PIPE NOTE: CONTRACTOR SHALL VERIFY THAT OUTSIDE DIAMETER OF 6" SCH 10 GALVANIZED PIPE WILL FIT THE BELL END OF A 6" PVC PIPE WHEN ORDERING MATERIALS. INSTALL RUBBER GASKET ELEVATION 'B' INSTALL 6" PVC PIPE WITH BELL END ROOF DOWNSPOUT, SEE ARCHITECTURAL FOR SIZE, FINISH AND DETAILS. BUILDING WALL. SEE STRUCTURAL DETAILS. PROVIDE FERNCO COUPLING OR APPROVED EQUIV. AS REQUIRED 2.0% MIN. 6" CAST IRON LONG SWEEP WITH NO HUBS/PLAIN END BUILDING FOUNDATION. SEE STRUCTURAL DETAILS 6" CLEANOUT SEE ELEVATION 'B' FINISH GRADE 24 " M I N 6" PVC PIPE (SEE PLAN) ELEVATION 'A'PROVIDE TRANSITION TO 6" CLEANOUT AS NECESSARY Downspout Connection with Wye Cleanout 6NTS FLOW CONTROL STRUCTURE DATA: RIM AND IE PER PLAN (SD A5 ) TOP OF RISER ELEVATION = 402.00 BOTTOM ORIFICE DIAMETER = 1.0625" BOTTOM ORIFICE ELEVATION = 396.00 RECTANGULAR NOTCH WIDTH = 0.25" RECTANGULAR NOTCH HEIGHT = 15" RECTANGULAR NOTCH ELEVATION = 400.75 Modular Wetland Water Quality Vault (SD A10)2NTS LINDBERGH HIGH SCHOOL FIELD IMPROVEMENTS STORM DRAINAGE DETAILS BLUE 4"x4" LOCATOR MARK AT CENTER OF COVER PANELIZED PAD 2" VELCRO INSTALL AND ADHERE TURF TO PANELIZED PAD 1" NYLON STRAPS 2 EACH CONTINUOUS BENEATH PANELIZED PAD, TRIM TO FIBER HEIGHT 4"4" INFILLED SYNTHETIC TURF SYSTEM SUPPLEMENTAL PAD COVER TO BE FLUSH WITH ADJACENT SYNTHETIC TURF ONCE IN PLACE 4" VELCRO INTEGRATED DUCTILE IRON FRAME AND SOLID GRATE (PER CIVIL) NYLOPLAST CATCH BASIN (SEE CIVIL) CONCRETE COLLAR COVER AT NYLOPLAST CATCH BASIN 48" 24" BLUE 4"x4" LOCATOR MARK CONCRETE COLLAR NYLOPLAST CATCH BASIN DRAINAGE PIPE - SEE SHEET F130 FOR PIPE TYPE OUTFLOW PIPE BASE COURSE AGGREGATE BACKFILL 8" 8" 48" 24" Turf Cover Nyloplast Basin 5NTS Catch Basin Type I 3NTS R-434411 CIVIL CONSTRUCTION PERMIT CIVIL CONSTRUCTION PERMIT RESUBMITTAL CIVIL CONSTRUCTION PERMIT RESUBMITTAL 2/21/25 4/14/25 6/06/25 6" M I N NEW UTILITY NEW UTILITY EXPANDED POLYSTYRENE FOAM PAD CUT TO SUPPORT TOP PIPE ETHAFOAM PAD SHALL BE OUTSIDE PIPE DIAMETER X OUTSIDE PIPE DIAMETER X3 INCHES WHERE OUTSIDE DIAMETER REFERS TO THE LARGER PIPE Ethafoam Pad 7NTS DEVELOPMENT ENGINEERING HBray 06/24/2025 388 389 390 391 392 NO R T H PROPOSED 12" SD IE 389.15 (IN) NW 387 EX 12" CPP IE 388.15 (OUT) N EX 8" CPP IE 388.45 (IN) E EX 12" CPP IE 388.25 (IN) S EX 12" CPP IE 388.55 (IN) W 10 3 / 4 " 13 1/4" CITY OF RENTON IN COMPLIANCE WITH CITY OF RENTON STANDARDS TE D - 4 0 - 4 3 4 4 43667 NSTATE O F WASHI N G T ON R EGIST E R E D P R O F E SSIONAL E N G IN EER O S B O CAJA.DLAREJ LU A 2 5 - 0 0 0 0 5 1 PR 2 5 - 0 0 0 0 1 8 C2 5 0 0 0 9 7 7 ACW JAJ ACW JAJ ACW JAJ LINDBERGH HIGH SCHOOL FIELD IMPROVEMENTS STORM DRAINAGE DETAILS Nyloplast Drain Basin Detail 1NTS StormTech Inserta Tee Side Inlet Connection 2NTS COMPACTED BACKFILL SLOPE MEETING GRADATION REQUIREMENTS FOR STRUCTURAL FILL (SEE NOTE 2) SLOPE TO DRAIN AWAY FROM STRUCTURE 6" BUILDING WALL. SEE STRUCTURAL PLANS GRAVEL BACKFILL FOR DRAINS PER PROJECT SPECIFICATIONS BUILDING FOOTING SEE STRUCTURAL PLANS 6" MIN 6" MIN 6" SDR 35 PVC PERF PIPE EXTERIOR USE ONLY CONNECT TO STORM CONVEYANCE SYSTEM. SURROUND W/ DRAIN ROCK AS SHOWN WRAP WITH NON-WOVEN SEPARATION FILTER FABRIC NOTES: 1.PIPE SHALL BE PLACED NO LOWER THAN 3" BELOW BOTTOM OF FOOTING 2.STRUCTURAL FILL SHALL MEET THE REQUIREMENTS OF SECTION 02200 OF THE PROJECT SPECIFICATIONS Footing Drain 3NTS R-434412 Existing Catch Basin Pipe Connections 4Scale: 1"=2' Not Used 5NTS CIVIL CONSTRUCTION PERMIT CIVIL CONSTRUCTION PERMIT RESUBMITTAL CIVIL CONSTRUCTION PERMIT RESUBMITTAL 2/21/25 4/14/25 6/06/25 DEVELOPMENT ENGINEERING HBray 06/24/2025 CITY OF RENTON IN COMPLIANCE WITH CITY OF RENTON STANDARDS TE D - 4 0 - 4 3 4 4 43667 NSTATE O F WASHI N G T ON R EGIST E R E D P R O F E SSIONAL E N G IN EER O S B O CAJA.DLAREJ LU A 2 5 - 0 0 0 0 5 1 PR 2 5 - 0 0 0 0 1 8 C2 5 0 0 0 9 7 7 ACW JAJ ACW JAJ ACW JAJ LINDBERGH HIGH SCHOOL FIELD IMPROVEMENTS STORM DRAINAGE DETAILS StormTech MC-7200 Chamber Specifications 1NTS StormTech Proposed Layout 2NTS Not Used 3NTS R-434413 CIVIL CONSTRUCTION PERMIT CIVIL CONSTRUCTION PERMIT RESUBMITTAL CIVIL CONSTRUCTION PERMIT RESUBMITTAL 2/21/25 4/14/25 6/06/25 DEVELOPMENT ENGINEERING HBray 06/24/2025 CITY OF RENTON IN COMPLIANCE WITH CITY OF RENTON STANDARDS TE D - 4 0 - 4 3 4 4 43667 NSTATE O F WASHI N G T ON R EGIST E R E D P R O F E SSIONAL E N G IN EER O S B O CAJA.DLAREJ LU A 2 5 - 0 0 0 0 5 1 PR 2 5 - 0 0 0 0 1 8 C2 5 0 0 0 9 7 7 ACW JAJ ACW JAJ ACW JAJ LINDBERGH HIGH SCHOOL FIELD IMPROVEMENTS GRADING & STORM DRAINAGE DETAILS StormTech Cross Section 1NTS StormTech Isolator Row 2NTS StormTech Connection Details 3NTS R-434414 6' 1' - 4 " 12' 1' - 4 " KEYSTONE STANDARD BLOCK OR APPROVED EQUIVALENT (TYP) MATCH EX GRADE EAST-WEST NORTH-SOUTH Block Wall 5NTS 12 8 T H A V E S E 8'-7/8" 40 INCHES 11 2 I N C H E S 72 I N C H E S SOLID WHITE SYMBOL, 6" HEIGHT (TYP) NOTES 1.SHARED LANE MARKING IN ACCORDANCE WITH MUTCD SECTION 9C.07. 2.PAVEMENT MARKINGS SHALL ADHERE TO RENTON STANDARD PLAN 109 EX CURB Bicycle Sharrow 4NTS CIVIL CONSTRUCTION PERMIT CIVIL CONSTRUCTION PERMIT RESUBMITTAL CIVIL CONSTRUCTION PERMIT RESUBMITTAL 2/21/25 4/14/25 6/06/25 6" DEVELOPMENT ENGINEERING HBray 06/24/2025 STORM PROFILE A Scale: 1"=5' V. 1"=20' H 385 390 395 400 405 410 415 385 390 395 400 405 410 415 CONNECT TO EX CATCH BASIN IE 389.15 12"(IN)NW CONTRACTOR TO CONFIRM IE PRIOR TO INSTALLATION SD A9 SDMH - 54" RIM 403.53 IE 396.00 12"(IN)NW IE 396.00 12"(OUT)SE 3' 3' 10 LF 8" SD @ 0.0% 13 LF 12" SD @ 0.6% 4 LF 12" SD @ 10.5% 48 LF 1 2 " SD @ 6 . 5 % SD A10 MODULAR WETLAND WATER QUALITY RIM 402.05 IE 395.53 12"(IN)NW IE 392.28 12"(OUT)SE 1.0' MIN APPROX ELEVATION OF EX ELEC/COMM. CONTRACTOR TO POTHOLE AND CONFIRM PRIOR TO ANY INSTALLATION OF STORM SYSTEM. SD A8 CB TYPE II - 48" RIM 404.07 IE 396.08 8"(BIDIRECTIONAL)N IE 399.38 8"(BIDIRECTIONAL)SW IE 396.08 12"(OUT)SE CITY OF RENTON IN COMPLIANCE WITH CITY OF RENTON STANDARDS TE D - 4 0 - 4 3 4 4 43667 NSTATE O F WASHI N G T ON R EGIST E R E D P R O F E SSIONAL E N G IN EER O S B O CAJA.DLAREJ LU A 2 5 - 0 0 0 0 5 1 PR 2 5 - 0 0 0 0 1 8 C2 5 0 0 0 9 7 7 ACW JAJ ACW JAJ ACW JAJ LINDBERGH HIGH SCHOOL FIELD IMPROVEMENTS STORM DRAINAGE PROFILES CIVIL CONSTRUCTION PERMIT CIVIL CONSTRUCTION PERMIT RESUBMITTAL CIVIL CONSTRUCTION PERMIT RESUBMITTAL R-434415 2/21/25 4/14/25 6/06/25 DEVELOPMENT ENGINEERING HBray 06/24/2025 MA T C H L I N E 3 + 2 0 STORM PROFILE B Scale: 1"=5' V. 1"=20' H 415 420 425 430 435 440 415 420 425 430 435 440 MA T C H L I N E 3 + 2 0 STORM PROFILE B Scale: 1"=5' V. 1"=20' H 390 395 400 405 410 415 420 425 430 390 395 400 405 410 415 420 425 430 SD A1 CB TYPE I RIM 405.26 IE 401.98 12"(IN)S IE 401.98 12"(OUT)NW INSTALL AS CLOSE TO EX CB AS POSSIBLE SD A3 30" NYLOPLAST BASIN RIM 405.34 IE 400.05 12"(IN)SW IE 396.08 8"(BIDIRECTIONAL)N IE 399.38 8"(BIDIRECTIONAL)E SD A2 CB TYPE I RIM 405.30 IE 401.90 12"(IN)SE IE 401.90 12"(OUT)NE 122 LF 12" SD @ 1.5% 8 LF 12" SD @ 0.9% 3 LF 12" SD @ 1.3% 67 LF 6" SD @ 0.2% 112 LF 6" SD @ 0.6%53 LF 6" SD @ 0.4%52 LF 6" SD @ 0.4% 1 1 1 L F 6 " S D @ 2 0 . 3 % EX GRADE (TYP)FINISHED GRADE (TYP) EX GRADE (TYP) FINISHED GRADE (TYP) IE 12" CPP=402.02 (N) EX 4" PERF PIPE IE 403.30 EX 4" PERF PIPE IE 403.28 EX 4" PERF PIPE IE 403.18 EX 4" PERF PIPE IE 403.31 EX 4" PERF PIPE IE 403.29 51 LF 6" SD @ 0.4% 51 LF 6" SD @ 0.4% 0.46'0.71'0.88'1.28'1.55'1.81' ETHAFOAM PAD SEE DETAIL C210 7 CITY OF RENTON IN COMPLIANCE WITH CITY OF RENTON STANDARDS TE D - 4 0 - 4 3 4 4 43667 NSTATE O F WASHI N G T ON R EGIST E R E D P R O F E SSIONAL E N G IN EER O S B O CAJA.DLAREJ LU A 2 5 - 0 0 0 0 5 1 PR 2 5 - 0 0 0 0 1 8 C2 5 0 0 0 9 7 7 ACW JAJ ACW JAJ ACW JAJ LINDBERGH HIGH SCHOOL FIELD IMPROVEMENTS STORM DRAINAGE PROFILES R-434416 CIVIL CONSTRUCTION PERMIT CIVIL CONSTRUCTION PERMIT RESUBMITTAL CIVIL CONSTRUCTION PERMIT RESUBMITTAL 2/21/25 4/14/25 6/06/25 DEVELOPMENT ENGINEERING HBray 06/24/2025 2.2% 1.4 % 4.8% 3.2 % 4.7% 0.5% 415 413 414 41 6417 41841 9 42 0 42 1 42 3 42 4 412 1.8 % 1.5 % 0.7% 1.4 % 1.3% 1.8% 1.8% 205' 20 5 ' 300' 350' 22.51' 79.74' 260.28' 37.41' 173.88' 64.80' 322.30' 101.29' 17 5 . 3 2 ' 16 6 . 2 3 ' 381.86' 1.8% 1.8% 22.51' 16.44' 16.11' CITY OF RENTON IN COMPLIANCE WITH CITY OF RENTON STANDARDS R-4344 TE D - 4 0 - 4 3 4 4 PR : LU A : C: LU A 2 5 - 0 0 0 0 5 1 PR 2 5 - 0 0 0 0 1 8 C2 5 0 0 0 9 7 7 D.A. Hogan & Associates, inc. 1450 114th Ave. SE, Suite 225 Bellevue, WA 98004 206-285-0400 CIVIL CONSTRUCTION PERMIT 2/21/25 CIVIL CONSTRUCTION PERMIT RESUBMITTAL 4/14/25 CIVIL CONSTRUCTION PERMIT RESUBMITTAL 6/4/25 LINDBERGH HIGH SCHOOL LAND USE SITE PLAN FIELD IMPROVEMENTS 17 A4 PROPERTY LINE SETBACK LINE LIMIT OF WORK LEGEND SITE DATA LEGAL DESCRIPTION A1 A2 B1 B2 C1 C2 A3 A4 B3 B4 FIELD LIGHT POLE (70'-80' HT.) LINDBERGH HIGH SCHOOL GYMNASIUM POOL LIGHTED TRACK & FIELD TENNIS COURTS 202 + 5 36 + 6 8 39 + 2 40 + 2 95,714 SF EXISTING UNDER DRAINED NATURAL GRASS PROPOSED CONVERSION TO SYNTHETIC TURF SURFACING 42,025 SF EXISTING UNDER DRAINED NATURAL GRASS PROPOSED CONVERSION TO SYNTHETIC TURF SURFACING TAX PARCEL NO. 282305-9004 ADDRESS: 16426 128TH AVE SE SE 1/4 OF NE 1/4 STR 28-23-05 LESS S 250 FT OF E 523 FT OF W 553 FT LESS CO RD PER RENTON DECLARATION OF LOT COMBINATION LUA 22-000106 REC #20240507000960 LEGEND: A SOFTBALL FIELD; NEW SYNTHETIC TURF SURFACING OVER EXISTING PLAYING SURFACES OVERALL FOOTPRINT. B BASEBALL FIELD; NEW SYNTHETIC TURF SURFACING OVER EXISTING PLAYING SURFACES OVERALL FOOTPRINT. C SOFTBALL + BASEBALL BATTING CAGES. MODIFIED EXISTING BATTING CAGES WITH NEW SYNTHETIC TURF AND PERMEABLE AGGREGATE SYSTEM. D MUSCO FIELD LIGHTING; 50fc INFIELD, 30fc OUTFIELD, LED. POLES 70' - 80' HEIGHT. E NEW BASEBALL / SOFTBALL DUGOUTS;EXPANDED TO 8' DEPTH x40' LENGTH, 30' OF PLAYER BENCHES. PARTIAL WIND SCREEN WRAP. F PORTABLE SANITARY FACILITIES; 2 EACH ACCESSIBLE UNITS ON A CONCRETE SERVICE PAD. G ADDITIONAL HARDSCAPE (CONCRETE), ACCOMMODATES THE FOLLOWING: IMPROVED ACCESS TO LOCKER/STORAGE AREA IN EXISTING SCHOOL, SEATING, ETC. H BID ALTERNATE #1: SCOREBOARDS; ONE AT EACH FIELD 8' x 24'. 20' OVERALL HEIGHT. I PUBLIC ADDRESS SYSTEM, INCLUDES POWER ACCESS / 110v - 30amp FOR PORTABLE EQUIPMENT. 36 + 6 PARKING (STD. + ADA) (325 + 15 TOTAL) NO CHANGE PROPOSED A B D E E E E F F G H H I I NEW / REPLACED HARD SURFACE (143,615 SF) C G LOT COVERAGE TOTAL SITE AREA: 1,622,480 SF EXISTING SITE IMPERIVIOUS AREA: 921,229 SF EXISTING IMPERVIOUS COVERAGE: 56.8% PROPOSED SITE IMPERVIOUS AREA: 930,485 SF PROPOSED IMPERVIOUS COVERAGE: 57.3% BUILDING AREA: 214,843 SF BUILDING COVERAGE: 13.2% EXISTING PAVEMENT AREA: 423,171 SF NEW PAVEMENT AREA: 4,606 SF TOTAL PAVEMENT AREA: 427,777 SF PARKING ANALYSIS: N/A BUILDING ANALYSIS: N/A - PROPOSED BUILDINGS ARE NOT OCCUPIABLE ON-SITE WETLAND AREA: 0 SF F NORTH NORTH 0 SCALE: 1" = 10' 10' 10' SOFTBALL 3rd BASE DUGOUT DEVELOPMENT ENGINEERING HBray 06/24/2025 2.2% 1.4 % 4.8% 3. 2 % 4.7% 0.5% 1.8 % 1.5 % 0.7% 1.4 % 1.3% 1.8% 1.8% 205' 20 5 ' SD SD SD SD SD SD S D S D SD 300 ' 350' UTILITY LEGEND CITY OF RENTON IN COMPLIANCE WITH CITY OF RENTON STANDARDS R-4344 TE D - 4 0 - 4 3 4 4 PR : LU A : C: LU A 2 5 - 0 0 0 0 5 1 PR 2 5 - 0 0 0 0 1 8 C2 5 0 0 0 9 7 7 D.A. Hogan & Associates, inc. 1450 114th Ave. SE, Suite 225 Bellevue, WA 98004 206-285-0400 CIVIL CONSTRUCTION PERMIT 2/21/25 CIVIL CONSTRUCTION PERMIT RESUBMITTAL 4/14/25 CIVIL CONSTRUCTION PERMIT RESUBMITTAL 6/4/25 LINDBERGH HIGH SCHOOL COMPOSITE UTILITY PLAN FIELD IMPROVEMENTS 18 ELECTRICAL CONDUIT STORM DRAINAGE STRUCTURE IRRIGATION MAINLINE IRRIGATION VALVE STRUCTURE STORM DRAINAGE COLLECTOR PIPE ELECTRICAL STRUCTURE STORM DRAINAGE BASIN SD FIELD LIGHT POLE NORTH DEVELOPMENT ENGINEERING HBray 06/24/2025 47.6 5 ' 64.4 7 ' 79.5 6 ' 94.6 6 ' 109 . 7 5 ' 124 . 8 5 ' 139 . 9 5 ' 152 . 1 0 ' 138 . 6 9 ' 125 . 2 8 ' 111 . 8 8 ' 96.9 0 ' 98.3 8 ' 84.9 8 ' 71.5 7 ' 30.8 2 ' 44.8 5 ' 7 (TYP.) 7 (TYP.) 8 (TYP.) 8 (TYP.) 8 (TYP.) 8 (TYP.) 8 (TYP.) 8 (TYP.) 9 (TYP.) 19 9 (TYP.) 19 9 (TYP.) 19 12 12 13 13 (TYP.) (TYP.) 14 (TYP.) 14 (TYP.) 14 (TYP.) 14 (TYP.) 15 15 16 (TYP.) 16 (TYP.) 16 (TYP.) 18 18 CATCH BASIN PROTECTION (TYP.) 11 CATCH BASIN PROTECTION (TYP.) 11 CATCH BASIN PROTECTION (TYP.) 11 21 (TYP.) 21 (TYP.) 21 (TYP.) CITY OF RENTON IN COMPLIANCE WITH CITY OF RENTON STANDARDS R-4344 TE D - 4 0 - 4 3 4 4 PR : LU A : C: LU A 2 5 - 0 0 0 0 5 1 PR 2 5 - 0 0 0 0 1 8 C2 5 0 0 0 9 7 7 D.A. Hogan & Associates, inc. 1450 114th Ave. SE, Suite 225 Bellevue, WA 98004 206-285-0400 CIVIL CONSTRUCTION PERMIT 2/21/25 CIVIL CONSTRUCTION PERMIT RESUBMITTAL 4/14/25 CIVIL CONSTRUCTION PERMIT RESUBMITTAL 6/4/25 LINDBERGH HIGH SCHOOL BASEBALL SITE PREPARATION PLAN FIELD IMPROVEMENTS 19 Know what's below. before you dig.Call R EXCAVATE TOP 2" OF PEA GRAVEL AT DRAINAGE LATERAL TRENCH; DISPOSE OF WASTE EXISTING CONCRETE CURBING TO BE REMOVED AND DISPOSED OF OFF SITE EXISTING CHAIN LINK FENCING TO BE REMOVED AND DISPOSED OF OFF SITE EXISTING NATURAL TURF TO BE REMOVED AND DISPOSED OF OFF SITE EXISTING INFIELD SOIL TO BE REMOVED AND DISPOSED OF OFF SITE SITE PREPARATION LEGEND NOTE LEGEND 1. (INDICATES GENERAL CONSTRUCTION NOTE) 3.(INDICATES SPECIFIC CONSTRUCTION KEYNOTE) EXISTING CRUSHED ROCK WARNING TRACK TO BE REMOVED AND DISPOSED OF OFF SITE EXISTING 3" PERF. CORR. POLY DRAIN TUBING TO REMAIN. PROTECT THROUGHOUT CONSTRUCTION. SITE PREPARATION NOTES 1.CALL 8-1-1 BEFORE YOU DIG. LOCATE, IDENTIFY AND VERIFY CONDITION OF ALL SITE UTILITIES PRIOR TO COMMENCING THE WORK. 2.PROVIDE TEMPORARY PROTECTION ON EXISTING PAVEMENTS FOR ALL CONSTRUCTION TRAFFIC AT FIELD ACCESS POINTS. TEMPORARY PROTECTION SHALL INCLUDE A MINIMUM OF THE FOLLOWING: 2.1.STRUCTURAL FABRIC OR GEOTEXTILE LAYER 2.2.3/4 INCH PLYWOOD (TWO DEEP) 3.PROTECT EXISTING ADJACENT SURFACES FROM DAMAGE DURING CONSTRUCTION. RESTORE ALL DISTURBED AREAS TO ORIGINAL OR BETTER CONDITION. 4.CONTRACTOR SHALL BE RESPONSIBLE FOR SECURING ALL GATES AND FENCES AT PERIMETER OF THIS SITE TO ESTABLISH A SECURE WORK AREA. WORK SHALL INCLUDE TEMPORARY 6' HIGH CHAIN LINK FENCING AT THE STAGING AND STORAGE AREAS. 5.REFER TO CIVIL SHEETS FOR TESC MEASURES AND ALL DEMOLITION OUTSIDE THE LIMITS OF THE BASEBALL AND SOFTBALL FIELDS. 6.COORDINATE WITH THE ARCHITECT AND DISTRICT MAINTENANCE STAFF TO FIELD LOCATE LOCATION OF EXISTING IRRIGATION SYSTEM COMPONENTS INCLUDING MAIN LINE, LATERAL PIPING AND EXISTING CONTROLLER WITHIN AREA OF WORK. 7.CONTRACTOR TO FIELD VERIFY LOCATION OF EXISTING IRRIGATION MAINLINE. REMOVE EXISTING IRRIGATION CONTROL VALVES AND CORRESPONDING BOXES AND VAULTS AND DELIVER TO THE OWNER ON SITE UNLESS OTHERWISE NOTED. CAP AND PROTECT EXISTING IRRIGATION MAINLINE TO REMAIN AT GATE VALVE FOR CONNECTION TO NEW IRRIGATION MAINLINE LOOP. 8.REMOVE EXISTING IRRIGATION SPRINKLER HEADS AND RISER ASSEMBLIES IN THE FIELD, CLEAN, PACKAGE AND DELIVER TO THE OWNER ONSITE. 9.STRIP AREA OF EXISTING SOD AND ORGANIC MATERIALS AND DISPOSE OF OFF SITE. ALL EXCESS AND UNSUITABLE SOIL MATERIALS SHALL BE REMOVED AND DISPOSED OF OFF SITE. 10.PROTECT EXISTING CATCH BASINS TO REMAIN DURING CONSTRUCTION. INSTALL TESC MEASURES AROUND RIMS AND MAINTAIN THROUGHOUT CONSTRUCTION. CLEAN DEBRIS FROM DRAINAGE SYSTEM BASINS WITHIN THE LIMIT OF WORK. REFER TO CIVIL PLANS. 11.NOT USED. 12.REMOVE EXISTING CHAIN LINK FENCING FABRIC AND DISPOSE OF OFF SITE. PROTECT THE EXISTING FENCE POSTS, FOUNDATIONS AND CONCRETE CURB TO REMAIN. 13.CUT AND CAP SUBSURFACE DRAINAGE LATERALS AS SHOWN. 14.REMOVE BASES, PLATES AND ANCHORS. CLEAN AND RETURN BASES AND PLATES TO THE OWNER ON SITE. BACKFILL ALL VOIDS WITH STRUCTURAL FILL, COMPACTED TO 95%. 15.REMOVE FOUL POLES AND FOUNDATIONS. 16.EXISTING BACKSTOP, WING FENCING AND OUTFIELD FENCING SHALL REMAIN IN PLACE, EXCEPT AS OTHERWISE NOTED. AT THE CONTRACTOR'S OPTION, SECTIONS OF THE EXISTING RAILS AND FABRIC TO REMAIN MAY BE REMOVED AND REINSTALLED TO FACILITATE THE ON-FIELD WORK AND OTHER MODIFICATIONS. 17.REMOVE TOP 3” OF ORGANICS AND AGGREGATE FROM THE BATTING CAGES. PROTECT EXISTING FENCE POSTS, FABRIC AND RAILS TO REMAIN. 18.REMOVE EXISTING BENCHES AT EACH BULLPEN. BACKFILL ALL VOIDS WITH STRUCTURAL FILL, COMPACTED TO 95%. 19.BACKFILL ALL VOIDS AND EXCAVATED AREAS WITH APPROVED STRUCTURAL FILL MATERIAL IN 12 INCH MAXIMUM LIFTS COMPACTED TO 95% MINIMUM. 20.PROTECT ALL UTILITIES TO REMAIN FROM DAMAGE THROUGH CONSTRUCTION. 21.PROTECT EXISTING SIDEWALK TO REMAIN. MATCHLINE TO SHEET F011 (NOTE PLAN VIEW ORIENTATION CHANGE) EXISTING 3" PERF. CORR. POLY DRAIN TUBING TO BE REMOVED NORTH CATCH BASIN PROTECTION DEVELOPMENT ENGINEERING HBray 06/24/2025 30.82' 44.85'8(TYP.) 8(TYP.) 12 12 1 3 (TYP.) 1 4 (TYP.) 1 4 (TYP.) 14 (TYP.) 1 6 (TYP.) 16 (TYP.) 1 6 (T Y P . ) CATCH BASIN PROTECTION (TYP.) 1 1 7 (TYP.) 7 (TYP.) 8 (TYP.) 8 (TYP.) 8 (TYP.) 8 (TYP.) 9 (TYP.) 19 9 (TYP.) 19 9 (TYP.) 19 CATCH BASIN PROTECTION (TYP.) 11 CATCH BASIN PROTECTION (TYP.) 11 12 12 14 (TYP.) 14 (TYP.) 14 (TYP.) 14 (TYP.) 15 15 16 16 16 17 18 18 21 (TYP.) 21 (TYP.) 21 21 (TYP.) 2 1 (TYP.) 21 (TYP.) CITY OF RENTON IN COMPLIANCE WITH CITY OF RENTON STANDARDS R-4344 TE D - 4 0 - 4 3 4 4 PR : LU A : C: LU A 2 5 - 0 0 0 0 5 1 PR 2 5 - 0 0 0 0 1 8 C2 5 0 0 0 9 7 7 D.A. Hogan & Associates, inc. 1450 114th Ave. SE, Suite 225 Bellevue, WA 98004 206-285-0400 CIVIL CONSTRUCTION PERMIT 2/21/25 CIVIL CONSTRUCTION PERMIT RESUBMITTAL 4/14/25 CIVIL CONSTRUCTION PERMIT RESUBMITTAL 6/4/25 LINDBERGH HIGH SCHOOL SOFTBALL SITE PREPARATION PLAN FIELD IMPROVEMENTS 20 Know what's below. before you dig.Call R MATCHLINE TO SHEET F010 (NOTE PLAN VIEW ORIENTATION CHANGE) NORTH MATCHLINE TO SHEET F010 (NOTE PLAN VIEW ORIENTATION CHANGE) (TYP.) EXCAVATE TOP 2" OF PEA GRAVEL AT DRAINAGE LATERAL TRENCH; DISPOSE OF WASTE EXISTING CONCRETE CURBING TO BE REMOVED AND DISPOSED OF OFF SITE EXISTING CHAIN LINK FENCING TO BE REMOVED AND DISPOSED OF OFF SITE EXISTING NATURAL TURF TO BE REMOVED AND DISPOSED OF OFF SITE EXISTING INFIELD SOIL TO BE REMOVED AND DISPOSED OF OFF SITE SITE PREPARATION LEGEND NOTE LEGEND 1. (INDICATES GENERAL CONSTRUCTION NOTE) 3.(INDICATES SPECIFIC CONSTRUCTION KEYNOTE) EXISTING CRUSHED ROCK WARNING TRACK TO BE REMOVED AND DISPOSED OF OFF SITE EXISTING 3" PERF. CORR. POLY DRAIN TUBING TO REMAIN. PROTECT THROUGHOUT CONSTRUCTION. SITE PREPARATION NOTES 1.CALL 8-1-1 BEFORE YOU DIG. LOCATE, IDENTIFY AND VERIFY CONDITION OF ALL SITE UTILITIES PRIOR TO COMMENCING THE WORK. 2.PROVIDE TEMPORARY PROTECTION ON EXISTING PAVEMENTS FOR ALL CONSTRUCTION TRAFFIC AT FIELD ACCESS POINTS. TEMPORARY PROTECTION SHALL INCLUDE A MINIMUM OF THE FOLLOWING: 2.1.STRUCTURAL FABRIC OR GEOTEXTILE LAYER 2.2.3/4 INCH PLYWOOD (TWO DEEP) 3.PROTECT EXISTING ADJACENT SURFACES FROM DAMAGE DURING CONSTRUCTION. RESTORE ALL DISTURBED AREAS TO ORIGINAL OR BETTER CONDITION. 4.CONTRACTOR SHALL BE RESPONSIBLE FOR SECURING ALL GATES AND FENCES AT PERIMETER OF THIS SITE TO ESTABLISH A SECURE WORK AREA. WORK SHALL INCLUDE TEMPORARY 6' HIGH CHAIN LINK FENCING AT THE STAGING AND STORAGE AREAS. 5.REFER TO CIVIL SHEETS FOR TESC MEASURES AND ALL DEMOLITION OUTSIDE THE LIMITS OF THE BASEBALL AND SOFTBALL FIELDS. 6.COORDINATE WITH THE ARCHITECT AND DISTRICT MAINTENANCE STAFF TO FIELD LOCATE LOCATION OF EXISTING IRRIGATION SYSTEM COMPONENTS INCLUDING MAIN LINE, LATERAL PIPING AND EXISTING CONTROLLER WITHIN AREA OF WORK. 7.CONTRACTOR TO FIELD VERIFY LOCATION OF EXISTING IRRIGATION MAINLINE. REMOVE EXISTING IRRIGATION CONTROL VALVES AND CORRESPONDING BOXES AND VAULTS AND DELIVER TO THE OWNER ON SITE UNLESS OTHERWISE NOTED. CAP AND PROTECT EXISTING IRRIGATION MAINLINE TO REMAIN AT GATE VALVE FOR CONNECTION TO NEW IRRIGATION MAINLINE LOOP. 8.REMOVE EXISTING IRRIGATION SPRINKLER HEADS AND RISER ASSEMBLIES IN THE FIELD, CLEAN, PACKAGE AND DELIVER TO THE OWNER ONSITE. 9.STRIP AREA OF EXISTING SOD AND ORGANIC MATERIALS AND DISPOSE OF OFF SITE. ALL EXCESS AND UNSUITABLE SOIL MATERIALS SHALL BE REMOVED AND DISPOSED OF OFF SITE. 10.PROTECT EXISTING CATCH BASINS TO REMAIN DURING CONSTRUCTION. INSTALL TESC MEASURES AROUND RIMS AND MAINTAIN THROUGHOUT CONSTRUCTION. CLEAN DEBRIS FROM DRAINAGE SYSTEM BASINS WITHIN THE LIMIT OF WORK. REFER TO CIVIL PLANS. 11.NOT USED. 12.REMOVE EXISTING CHAIN LINK FENCING FABRIC AND DISPOSE OF OFF SITE. PROTECT THE EXISTING FENCE POSTS, FOUNDATIONS AND CONCRETE CURB TO REMAIN. 13.CUT AND CAP SUBSURFACE DRAINAGE LATERALS AS SHOWN. 14.REMOVE BASES, PLATES AND ANCHORS. CLEAN AND RETURN BASES AND PLATES TO THE OWNER ON SITE. BACKFILL ALL VOIDS WITH STRUCTURAL FILL, COMPACTED TO 95%. 15.REMOVE FOUL POLES AND FOUNDATIONS. 16.EXISTING BACKSTOP, WING FENCING AND OUTFIELD FENCING SHALL REMAIN IN PLACE, EXCEPT AS OTHERWISE NOTED. AT THE CONTRACTOR'S OPTION, SECTIONS OF THE EXISTING RAILS AND FABRIC TO REMAIN MAY BE REMOVED AND REINSTALLED TO FACILITATE THE ON-FIELD WORK AND OTHER MODIFICATIONS. 17.REMOVE TOP 3” OF ORGANICS AND AGGREGATE FROM THE BATTING CAGES. PROTECT EXISTING FENCE POSTS, FABRIC AND RAILS TO REMAIN. 18.REMOVE EXISTING BENCHES AT EACH BULLPEN. BACKFILL ALL VOIDS WITH STRUCTURAL FILL, COMPACTED TO 95%. 19.BACKFILL ALL VOIDS AND EXCAVATED AREAS WITH APPROVED STRUCTURAL FILL MATERIAL IN 12 INCH MAXIMUM LIFTS COMPACTED TO 95% MINIMUM. 20.PROTECT ALL UTILITIES TO REMAIN FROM DAMAGE THROUGH CONSTRUCTION. 21.PROTECT EXISTING SIDEWALK TO REMAIN. EXISTING 3" PERF. CORR. POLY DRAIN TUBING TO BE REMOVED CATCH BASIN PROTECTION DEVELOPMENT ENGINEERING HBray 06/24/2025 30 0 ' 350 ' 205' 20 5 ' CITY OF RENTON IN COMPLIANCE WITH CITY OF RENTON STANDARDS R-4344 TE D - 4 0 - 4 3 4 4 PR : LU A : C: LU A 2 5 - 0 0 0 0 5 1 PR 2 5 - 0 0 0 0 1 8 C2 5 0 0 0 9 7 7 D.A. Hogan & Associates, inc. 1450 114th Ave. SE, Suite 225 Bellevue, WA 98004 206-285-0400 CIVIL CONSTRUCTION PERMIT 2/21/25 CIVIL CONSTRUCTION PERMIT RESUBMITTAL 4/14/25 CIVIL CONSTRUCTION PERMIT RESUBMITTAL 6/4/25 LINDBERGH HIGH SCHOOL FIELD COLOR PLANS FIELD IMPROVEMENTS 21SOFTBALL FIELDBASEBALL FIELD NORTH NORTH DEVELOPMENT ENGINEERING HBray 06/24/2025 S D SD SD S D S D S D SD SD SD SD SD S D S D SD SD SDSDSD SD SD SD 30 0 ' 350 ' 1 1 CONCRETE RETAINING CURB 2 5 . 0 0 ' 12.00' WARNING TRACK (TYP.) 12.00' WARNING TRACK (TYP.) 12.00' WARNING TRACK (TYP.) F210 1 F210 1 F210 1 F210 1 F210 1 F220 5 F310 1 90.00' (TYP.) F220 1 F240 1 F222 1 F240 1 BASEBALL MARKINGS (TYP.)HOME PLATE BASEBALL BATTER'S BOX TYPICAL BASE AND PLATE ANCHOR LAYOUT SYNTHETIC TURF PITCHING MOUND BROWN SYNTHETIC TURF (TYP.) BROWN SYNTHETIC TURF WARNING TRACK (TYP.) BROWN SYNTHETIC TURF WARNING TRACK (TYP.) BASEBALL BULLPEN AREA BULLPEN PITCHING MOUND FOUL POLE, INTEGRATED IN EXISTING FENCE (TYP.) FOUL POLE, INTEGRATED IN EXISTING FENCE (TYP.) ALTERNATE BID #1: SCOREBOARD AND FOUNDATIONS. SEE ARCHITECTURAL PLANS FOR FOUNDATION INFORMATION. REPLACE ALL EXISTING BALL CONTROL NETTING OVER FENCING WITH NEW NETTING (TYP.) REPLACE NETTING ON EXISTING CABLE (TYP.) GREEN SYNTHETIC TURF (TYP.) GREEN SYNTHETIC TURF (TYP.) GREEN SYNTHETIC TURF (TYP.) GREEN SYNTHETIC TURF (TYP.) DUGOUT STRUCTURE (TYP.) DUGOUT STRUCTURE (TYP.) FIELD LIGHT (TYP.) FIELD LIGHT (TYP.) FIELD LIGHT (TYP.) FIELD LIGHT (TYP.) CONCRETE RETAINING CURB BULLPEN PITCHER'S MOUND F250 1F250 3 F250 3 QUICK COUPLING VALVE (TYP.)9 F260 1 QUICK COUPLING VALVE (TYP.)9 F260 1 QUICK COUPLING VALVE (TYP.)9 F260 1 SYNTHETIC TURF EDGE ANCHOR AT EXISTING CONCRETE CURB 1 F221 1 SYNTHETIC TURF EDGE ANCHOR AT EXISTING CONCRETE CURB 1 F221 1 SYNTHETIC TURF EDGE ANCHOR AT EXISTING CONCRETE CURB 1 F221 1 2 2 4 4 NEW CONCRETE TO MEET AND MATCH EXISTING CONCRETE PAVING 5 11 11 12 12 SY N T H E T I C T U R F E D G E ANC H O R A T E X I S T I N G CO N C R E T E C U R B 1 QU I C K C O U P L I N G VA L V E ( T Y P . ) 9 F310 2 STORMTECH DETENTION CHAMBERS, SEE CIVIL PLANS CONCRETE RETAINING WALL BLOCK RETAINING WALL 40 LF B 8 LF B 8 LF B 40 LF A 40 L F A 40 L F B 8 LF B 8 LF B 18 L F B 18 LF B 48 " G R A D I N G TR A N S I T I O N A T FI E L D E D G E ( T Y P . ) 48" GRADING TRANSITION AT FIELD EDGE (TYP.) 48" GRADING TRANSITION AT FIELD EDGE (TYP.) 48" GRADING TRANSITION AT FIELD EDGE (TYP.) F222 5 F222 5 REPLACE ALL EXISTING BALL CONTROL NETTING OVER FENCING WITH NEW NETTING (TYP.) F231 1 F231 1 17 L F E OUTFIELD FENCE WINDSCREEN 14 F222 2 FENCE CAP (TYP.)14F222 3 FE N C E C A P F22 2 3 RAMP HANDRAIL, SEE CIVIL PLANS F270 3 LAYOUT AND FENCING NOTES NOTE LEGEND 1. (INDICATES GENERAL CONSTRUCTION NOTE) 3.(INDICATES SPECIFIC CONSTRUCTION KEYNOTE) MATCHLINE TO SHEET F111 (NOTE PLAN VIEW ORIENTATION CHANGE) CITY OF RENTON IN COMPLIANCE WITH CITY OF RENTON STANDARDS R-4344 TE D - 4 0 - 4 3 4 4 PR : LU A : C: LU A 2 5 - 0 0 0 0 5 1 PR 2 5 - 0 0 0 0 1 8 C2 5 0 0 0 9 7 7 D.A. Hogan & Associates, inc. 1450 114th Ave. SE, Suite 225 Bellevue, WA 98004 206-285-0400 CIVIL CONSTRUCTION PERMIT 2/21/25 CIVIL CONSTRUCTION PERMIT RESUBMITTAL 4/14/25 CIVIL CONSTRUCTION PERMIT RESUBMITTAL 6/4/25 LINDBERGH HIGH SCHOOL BASEBALL LAYOUT PLAN FIELD IMPROVEMENTS 22 CHAIN LINK FENCE LAYOUT AND FENCING LEGEND NEW SYNTHETIC TURF EDGE ANCHOR ON EXISTING CONTAINMENT CURB GREEN SYNTHETIC TURF AND PERMEABLE AGGREGATE BROWN SYNTHETIC TURF AND PERMEABLE AGGREGATE LIGHT POLE, SEE ELECTRICAL CONCRETE PAVING NORTH NETTING ON EXISTING CABLES B 3 FENCE TYPE AND LIMIT GATE TYPE A 25' OVERALL; 10' HEIGHT CHAIN LINK FENCE; 2" MESH X9 GAUGE, TOP, MIDDLE, BOTTOM RAIL, 15' X2"SQ. NYLON NETTING ABOVE B 10' HEIGHT CHAIN LINK FENCE; 2" MESH X9 GAUGE, TOP, MIDDLE, BOTTOM RAIL C 4' HEIGHT CHAIN LINK FENCE; 2" MESH x9 GAUGE, TOP AND BOTTOM RAIL D BATTING CAGE NET TUNNEL E REPLACE BACKSTOP STOP BOARDS & PADS (FIELD VERIFY) FENCE TYPE KEY 1 5' SINGLE SWING GATE GATE TYPE KEY (ALL CHAIN LINK) 1.FURNISH AND INSTALL PERMEABLE AGGREGATE AND SYNTHETIC TURF EDGE ANCHORING SYSTEM AROUND THE ENTIRE PERIMETER OF THE SYNTHETIC TURF FIELD AREAS INCLUDING BASE BID BATTING CAGES. 2.PRIOR TO INSTALLATION OF ANY IMPROVEMENTS AT THE BASEBALL AND SOFTBALL INFIELD, CONTRACTOR SHALL ACCURATELY SURVEY AND FIELD CONFIRM THE LOCATION OF HOME PLATE, 1st, 2nd AND 3rd BASE, FOUL POLE AND FOUL LINE. CONFIRMATION AND SUBSEQUENT CONSTRUCTION, INCLUDING INSTALLATION OF NEW FOUL POLES, BASE ANCHORS, AND PLATES, SO THAT FIRST AND THIRD BASE LINES RESULT IN AN INTERNAL 90 DEGREE ANGLE, AND THAT LOCATION OF FOUL POLES REPRESENT A TRUE EXTENSION OF EACH FOUL LINE. 3.RESTORE ALL DISTURBED NON-SURFACE PERIMETER AREAS. 4.FOUL POLES ARE LOCATED IN FAIR TERRITORY, COORDINATED WITH THE PLACEMENT OF HOME PLATE AT THE DISTANCES INDICATED. OUTSIDE FACE OF BOTH POLES TO FORM A 90 DEGREE ANGLE WITH THE BACK OF HOME PLATE AT THE APEX. 5.NEW PAVING TO MEET AND MATCH FLUSH WITH EXISTING ADJACENT SURFACES WHERE INDICATED. 6.SEE ELECTRICAL SHEETS FOR CONDUIT TO SCOREBOARDS, LIGHTS AND POWER SUPPLY TO THE BATTING CAGES. 7.RESTORATION LIMIT SHOWN IS THE MINIMUM ANTICIPATED LIMIT OF DISTURBANCE. ANY ADDITIONAL DISTURBANCE CREATED AS A RESULT OF THE CONTRACTORS WORK SHALL BE RESTORED AS DIRECTED WITHOUT ADDITIONAL COMPENSATION EXCEPT AS AGREED IN ADVANCE OF THE INITIAL DISTURBANCE. RESTORATION SHALL BE TO A LIKE CONDITION. 8.THE CONTRACTOR SHALL FIELD VERIFY SYNTHETIC TURF SURFACING DIMENSIONS TO MATCH EXISTING FIELD AREA. SEE SYNTHETIC TURF COMPOSITE PLAN AND LAYOUT PLANS & DETAILS FOR SYNTHETIC TURF LINES AND MARKINGS. 9.INSTALL NEW QUICK COUPLING VALVE IN TURFCOOL VALVE BOX. 10.COORDINATE FENCE POST LOCATIONS TO AVOID EXISTING OR PROPOSED UTILITIES. 11.FURNISH AND INSTALL DUGOUTS COMPLETE FOR THE BASEBALL AND SOFTBALL FIELDS. 12.REMOVE AND REPLACE THE LOWER 10' OF CHAIN LINK FENCE FABRIC BETWEEN THE ENDS OF THE DUGOUTS USING NEW 6 GAUGE GALVANIZED WIRE FABRIC. 13.PROVIDE NEW BACKSTOP BOARDS AND PADS AS SHOWN. 14.PROVIDE NEW FENCE SAFETY CAP AT ALL FENCES 10' HT. AND UNDER, AND 120 LF OF WINDSCREEN CENTERED ON CENTER FIELD. 15.PROVIDE EXPANSION FOR ALL CONCRETE PAVING AT 40' ON CENTER. PROVIDE CONTROL JOINTS AND CONCRETE SCORING PATTERN AT ALL FENCE POST LOCATIONS AT 10' ON CENTER. QUICK COUPLING VALVE CAST-IN-PLACE RETAINING WALL BLOCK RETAINING WALL DEVELOPMENT ENGINEERING HBray 06/24/2025 205' 20 5 ' 1 1 1 1 D D 25 . 0 0 ' 25.0 0 ' 12.00' WARNING TRACK (TYP.) 12.00' WARNING TRACK (TYP.) F210 1 F220 5 F310 1 F220 1 F 2 4 0 1 F240 1 B A S E B A L L MARKINGS (TYP.) HOME PLATE BASEBALL BATTER'S B O X T Y P I C A L B A S E AND PLATE A N C H O R L A Y O U T SYNTHETIC TURF PI T C H I N G M O U N D FOUL POLE TO BE INTEGRATED IN EXISTING FENCE (TYP.) REPLACE ALL EXISTING BALL CONTROL NETTING OVER FENCING WITH NEW NETTING (TYP.) R E P L A C E A L L E X I S T I N G BALL CONTROL NETTING OVER FENCING WITH NEW NETTING (TYP.) R E P L A C E N E T T I N G ON EXISTING CABLE (TYP.) SOFTBALL MARKINGS (TYP.) HOME PLATE SOFTBALL BATTER'S BOX TYPICAL BASE AND PLATE ANCHOR LAYOUT SOFTBALL PITCHING PLATE BROWN SYNTHETIC TURF (TYP.) BROWN SYNTHETIC TURF WARNING TRACK (TYP.) SOFTBALL BULLPEN AREA SOFTBALL BULLPEN AREA TURF (TYP.) GREEN SYNTHETIC TURF (TYP.) BASEBALL BATTING CAGE SOFTBALL BATTING CAGE CONCRETE WALKWAY CONCRETE STAIRS (TYP.) CONCRETE PAVING (TYP.) RELOCATE EXISTING 3-ROW BLEACHERS DUGOUT STRUCTURE (TYP.) DUGOUT STRUCTURE (TYP.) DUGOUTS T R U C T U R E (TYP.) DUGOUTSTRUCTURE (TYP.) FIELD LIGHT (TYP.) FIELD LIGHT (TYP.) FIELD LIGHT (TYP.) FIELD LIGHT (TYP.) ALTERNATE BID #1: SCOREBOARD AND FOUNDATIONS. SEE ARCHITECTURAL PLANS FOR FOUNDATION INFORMATION. CONCRETE PAVING Q U I C K C O U P L I N G VALVE (TYP.) 9F 2 6 0 1 SYNTHETIC TURF EDGE A N C H O R A T E X I S T I N G CONCRETE CURB 1 F221 1 2 2 NEW CONCRETE TO MEET AND MATCH E X I S T I N G C O N C R E T E P A V I N G 5 11 11 1 2 12 SYNTHETIC TURF EDGE ANCHOR AT EXISTING CONCRETE CURB 1 F221 1 SYNTHETIC TURF EDGE ANCHOR AT EXISTING CONCRETE CURB 1 F221 1 BROWN SYNTHETIC TURF WARNING TRACK (TYP.) F250 2 NEW CONCRETE TO MEET AND MATCH EXISTING CONCRETE PAVING 5 SYNTHETIC TURF EDGE ANCHOR AT EXISTING CONCRETE CURB 1 F221 1 2 2 2 F220 1 60.00' (TYP.) 4 FOUL POLE TO BE INTEGRATED IN EXISTING FENCE (TYP.)4 QUICK COUPLING VALVE (TYP.) 9 F260 1 QUICK COUPLING VALVE (TYP.)9 F260 1 11 F240 1 11 F240 1 12 12 F210 1 F210 1 GREEN SYNTHETIC TURF (TYP.) F210 1 F220 4 F320 1 F320 2 F 3 1 0 2 F222 1 F250 2 F270 1 F210 3 CONCRETE R E T A I N I N G WALL CONCRETE RETAINING WALL BLOCK R E T A I N I N G WALL 40 LF B 8 LF B 8 LF B 40 LF A 40 L F A 40 L F B 8 L F B 70 LF A 40 LF B 8 LF B 8 LF B 8 LF B 70 LF A 43 LF B 8 LF B 2 LF C 26 LF C 8 LF B F251 1 F251 1 48" GRADING TRANSITION AT FIELD EDGE (TYP.) 48" GRADING TRANSITION AT FIELD EDGE (TYP.) 48" GRADING TRANSITION AT FIELD EDGE (TYP.) 48" GRADING T R A N S I T I O N A T FIELD EDGE (TYP.) F210 3 F222 5 F222 5 F210 3 REPLACE ALL EXISTING BALL CONTROL NETTING OVER FENCING WITH N E W N E T T I N G ( T Y P . ) F231 1 F 2 3 1 1 F231 1 REPLACE ALL EXISTING BALL CONTROL NETTING OVER FENCING WITH NEW NETTING (TYP.) F231 1 17 LF E 2 0 L F E OUTFIELD FENCE WINDSCREEN14 F222 2 FENCE CAP (TYP.)14 F222 3 RAMP HANDRAIL, SEE CIVIL PLANS F270 3 MATCHLINE TO SHEET F110 (NOTE PLAN VIEW ORIENTATION CHANGE) CITY OF RENTON IN COMPLIANCE WITH CITY OF RENTON STANDARDS R-4344 TE D - 4 0 - 4 3 4 4 PR : LU A : C: LU A 2 5 - 0 0 0 0 5 1 PR 2 5 - 0 0 0 0 1 8 C2 5 0 0 0 9 7 7 D.A. Hogan & Associates, inc. 1450 114th Ave. SE, Suite 225 Bellevue, WA 98004 206-285-0400 CIVIL CONSTRUCTION PERMIT 2/21/25 CIVIL CONSTRUCTION PERMIT RESUBMITTAL 4/14/25 CIVIL CONSTRUCTION PERMIT RESUBMITTAL 6/4/25 LINDBERGH HIGH SCHOOL SOFTBALL LAYOUT PLAN FIELD IMPROVEMENTS 23 NORTH MATCHLINE TO SHEET F110 (NOTE PLAN VIEW ORIENTATION CHANGE) LAYOUT AND FENCING NOTES NOTE LEGEND 1. (INDICATES GENERAL CONSTRUCTION NOTE) 3.(INDICATES SPECIFIC CONSTRUCTION KEYNOTE) CHAIN LINK FENCE LAYOUT AND FENCING LEGEND NEW SYNTHETIC TURF EDGE ANCHOR ON EXISTING CONTAINMENT CURB GREEN SYNTHETIC TURF AND PERMEABLE AGGREGATE BROWN SYNTHETIC TURF AND PERMEABLE AGGREGATE LIGHT POLE, SEE ELECTRICAL CONCRETE PAVING NETTING ON EXISTING CABLES B 3 FENCE TYPE AND LIMIT GATE TYPE A 25' OVERALL; 10' HEIGHT CHAIN LINK FENCE; 2" MESH X9 GAUGE, TOP, MIDDLE, BOTTOM RAIL, 15' X2"SQ. NYLON NETTING ABOVE B 10' HEIGHT CHAIN LINK FENCE; 2" MESH X9 GAUGE, TOP, MIDDLE, BOTTOM RAIL C 4' HEIGHT CHAIN LINK FENCE; 2" MESH x9 GAUGE, TOP AND BOTTOM RAIL D BATTING CAGE NET TUNNEL E REPLACE BACKSTOP STOP BOARDS & PADS (FIELD VERIFY) FENCE TYPE KEY 1 5' SINGLE SWING GATE GATE TYPE KEY (ALL CHAIN LINK) 1.FURNISH AND INSTALL PERMEABLE AGGREGATE AND SYNTHETIC TURF EDGE ANCHORING SYSTEM AROUND THE ENTIRE PERIMETER OF THE SYNTHETIC TURF FIELD AREAS INCLUDING BASE BID BATTING CAGES. 2.PRIOR TO INSTALLATION OF ANY IMPROVEMENTS AT THE BASEBALL AND SOFTBALL INFIELD, CONTRACTOR SHALL ACCURATELY SURVEY AND FIELD CONFIRM THE LOCATION OF HOME PLATE, 1st, 2nd AND 3rd BASE, FOUL POLE AND FOUL LINE. CONFIRMATION AND SUBSEQUENT CONSTRUCTION, INCLUDING INSTALLATION OF NEW FOUL POLES, BASE ANCHORS, AND PLATES, SO THAT FIRST AND THIRD BASE LINES RESULT IN AN INTERNAL 90 DEGREE ANGLE, AND THAT LOCATION OF FOUL POLES REPRESENT A TRUE EXTENSION OF EACH FOUL LINE. 3.RESTORE ALL DISTURBED NON-SURFACE PERIMETER AREAS. 4.FOUL POLES ARE LOCATED IN FAIR TERRITORY, COORDINATED WITH THE PLACEMENT OF HOME PLATE AT THE DISTANCES INDICATED. OUTSIDE FACE OF BOTH POLES TO FORM A 90 DEGREE ANGLE WITH THE BACK OF HOME PLATE AT THE APEX. 5.NEW PAVING TO MEET AND MATCH FLUSH WITH EXISTING ADJACENT SURFACES WHERE INDICATED. 6.SEE ELECTRICAL SHEETS FOR CONDUIT TO SCOREBOARDS, LIGHTS AND POWER SUPPLY TO THE BATTING CAGES. 7.RESTORATION LIMIT SHOWN IS THE MINIMUM ANTICIPATED LIMIT OF DISTURBANCE. ANY ADDITIONAL DISTURBANCE CREATED AS A RESULT OF THE CONTRACTORS WORK SHALL BE RESTORED AS DIRECTED WITHOUT ADDITIONAL COMPENSATION EXCEPT AS AGREED IN ADVANCE OF THE INITIAL DISTURBANCE. RESTORATION SHALL BE TO A LIKE CONDITION. 8.THE CONTRACTOR SHALL FIELD VERIFY SYNTHETIC TURF SURFACING DIMENSIONS TO MATCH EXISTING FIELD AREA. SEE SYNTHETIC TURF COMPOSITE PLAN AND LAYOUT PLANS & DETAILS FOR SYNTHETIC TURF LINES AND MARKINGS. 9.INSTALL NEW QUICK COUPLING VALVE IN TURFCOOL VALVE BOX. 10.COORDINATE FENCE POST LOCATIONS TO AVOID EXISTING OR PROPOSED UTILITIES. 11.FURNISH AND INSTALL DUGOUTS COMPLETE FOR THE BASEBALL AND SOFTBALL FIELDS. 12.REMOVE AND REPLACE THE LOWER 10' OF CHAIN LINK FENCE FABRIC BETWEEN THE ENDS OF THE DUGOUTS USING NEW 6 GAUGE GALVANIZED WIRE FABRIC. 13.PROVIDE NEW BACKSTOP BOARDS AND PADS AS SHOWN. 14.PROVIDE NEW FENCE SAFETY CAP AT ALL FENCES 10' HT. AND UNDER, AND 120 LF OF WINDSCREEN CENTERED ON CENTER FIELD. 15.PROVIDE EXPANSION FOR ALL CONCRETE PAVING AT 40' ON CENTER. PROVIDE CONTROL JOINTS AND CONCRETE SCORING PATTERN AT ALL FENCE POST LOCATIONS AT 10' ON CENTER. QUICK COUPLING VALVE CAST-IN-PLACE RETAINING WALL BLOCK RETAINING WALL DEVELOPMENT ENGINEERING HBray 06/24/2025 S D SD SD SD S D S D SD SD SD SD S D S D S D SD SD SDSDSD SD SD SD 30 0 ' 350 ' 405 404 . 5 404 403 . 5 S=1.0% S = 1 . 0 % S= 1 . 0 % S=1.0% S= 1 . 0 % S = 1 . 0 % S=1 . 0 % S = 1 . 0 % S=1 . 0 % S = 1 . 0 % 403.05 403.39 403.39 405.00 405.00 405.00 405.83 405.00 405.00 TW 405.21 BW 402.96 TW 405.21 BW 405.21 TW 399.00 BW 397.00 404.25 405.08 404.21 404.29 405.13 404.28 48 " G R A D I N G TRA N S I T I O N A T FI E L D E D G E ( T Y P . ) 48" GRADING TRANSITION AT FIELD EDGE (TYP.) 48" GRADING TRANSITION AT FIELD EDGE (TYP.) 48" GRADING TRANSITION AT FIELD EDGE (TYP.) S=1.5% Know what's below. before you dig.Call R CITY OF RENTON IN COMPLIANCE WITH CITY OF RENTON STANDARDS R-4344 TE D - 4 0 - 4 3 4 4 PR : LU A : C: LU A 2 5 - 0 0 0 0 5 1 PR 2 5 - 0 0 0 0 1 8 C2 5 0 0 0 9 7 7 D.A. Hogan & Associates, inc. 1450 114th Ave. SE, Suite 225 Bellevue, WA 98004 206-285-0400 CIVIL CONSTRUCTION PERMIT 2/21/25 CIVIL CONSTRUCTION PERMIT RESUBMITTAL 4/14/25 CIVIL CONSTRUCTION PERMIT RESUBMITTAL 6/4/25 LINDBERGH HIGH SCHOOL BASEBALL GRADING PLAN FIELD IMPROVEMENTS 24 MATCHLINE TO SHEET F121 (NOTE PLAN VIEW ORIENTATION CHANGE) CONSTANT SURFACE SLOPE SURFACE SLOPE NEW HALF CONTOUR LINES411.5 411 NEW CONTOUR LINES SPOT ELEVATION SURVEY CONTOUR LINES GRADING LEGEND MATCH TO EXISTING GRADING NOTES 1.THE CONTRACTOR SHALL CALL AND NOTIFY DIGALERT AT 8-1-1 A MINIMUM OF 2 WORKING DAYS BEFORE DEMOLITION, DIGGING, OR GRADING OPERATIONS OCCUR. 2.PROVIDE CONSTANT SLOPES TO PREVENT PONDING WATER IN ALL PERIMETER AREAS. 3.STRIP FIELD AREA OF EXISTING SOD, ORGANIC MATERIALS, AND FIELD SECTION SAND MATERIALS AND DISPOSE OF OFF SITE. ALL EXCESS AND UNSUITABLE SOIL MATERIAL SHALL BE REMOVED AND DISPOSED OF OFF SITE. 4.HYDROSEED ALL DISTURBED LAWN AREAS AND RESTORE TO EXISTING OR BETTER CONDITION. 5.FURNISH AND INSTALL PERMEABLE FIELD BASE MATERIALS FOR THE ENTIRE SYNTHETIC TURF FIELD AREA INCLUDING 8 INCHES MINIMUM OF BASE COURSE PERMEABLE AGGREGATE AND 2 INCHES MINIMUM OF TOP COURES PERMEABLE AGGREGATE. 6.BACKFILL AND COMPACTE EXCAVATED AREAS RESULTING FROM DEMOLITION ACTIVITIES WITH SELECT FEILL TO 95% WITH 12” MAX. LIFTS. 7.THE CONTRACTOR SHALL NOTIFY THE ENGINEER IN THE EVENT OR DISCOVERY OF POOR SOILS, GROUNDWATER OR DISCREPANCIES IN THE EXISTING CONDITIONS AS NOTED ON THE PLANS. NOTE LEGEND 1. (INDICATES GENERAL CONSTRUCTION NOTE) 3.(INDICATES SPECIFIC CONSTRUCTION KEYNOTE) c 411.52 S=2.0% GRADE BREAK NORTH RETAINING WALL CHAIN LINK FENCE CHAIN LINK FENCE AND CONCRETE CURB BW 369.40 TW 374.85 BOTTOM OF WALL ELEVATION TOP OF WALL ELEVATION LIMIT OF PERMEABLE AGGREGATE 48" GRADE TRANSITION AT FIELD EDGE DEVELOPMENT ENGINEERING HBray 06/24/2025 205' 20 5 ' SD SD SD SD SD SD SD S=2.0% 4 3 0 4 2 9 . 5 429 42 9 S=1.0% S=1. 0 % S= 1 . 0 % 405.00 4 0 5 . 0 0 4 0 5 . 0 0 4 0 5 . 8 3 4 0 5 . 0 0 405.00 428.85 428.85 430.00 430.00 430.00 430.00 T W 4 0 5 . 2 1 BW 402.96 TW 405.21 BW 405.21 TW 399.00 BW 397.00 TW 430.73 BW 429.44 TW 430.39 BW 430.39 428.22 428.22 428.22 S=0.9%428.50 S=1 . 5 % S=2.0% 428.13 425.05 424.79 415.72 415.47 412.50 421.82 418.77 418.68 421.73 412.50 412.50 412.50 412.50 48" GRADING TRANSITION AT FIELD EDGE (TYP.) 48" GRADING TRANSITION AT FIELD EDGE (TYP.) 48" GRADING TRANSITION AT FIELD EDGE (TYP.) 48" GRADING T R A N S I T I O N A T FIELD EDGE (TYP.) 48" GRADING TRANSITION AT FI E L D E D G E ( T Y P . ) S=1.5% S=1.5% TW 430.66 BW 430.47 CITY OF RENTON IN COMPLIANCE WITH CITY OF RENTON STANDARDS R-4344 TE D - 4 0 - 4 3 4 4 PR : LU A : C: LU A 2 5 - 0 0 0 0 5 1 PR 2 5 - 0 0 0 0 1 8 C2 5 0 0 0 9 7 7 D.A. Hogan & Associates, inc. 1450 114th Ave. SE, Suite 225 Bellevue, WA 98004 206-285-0400 CIVIL CONSTRUCTION PERMIT 2/21/25 CIVIL CONSTRUCTION PERMIT RESUBMITTAL 4/14/25 CIVIL CONSTRUCTION PERMIT RESUBMITTAL 6/4/25 LINDBERGH HIGH SCHOOL SOFTBALL GRADING PLAN FIELD IMPROVEMENTS 25 MATCHLINE TO SHEET F120 (NOTE PLAN VIEW ORIENTATION CHANGE) Know what's below. before you dig.Call R CONSTANT SURFACE SLOPE SURFACE SLOPE NEW HALF CONTOUR LINES411.5 411 NEW CONTOUR LINES SPOT ELEVATION GRADING LEGEND MATCH TO EXISTING RETAINING WALL CHAIN LINK FENCE CHAIN LINK FENCE AND CONCRETE CURB BW 369.40 TW 374.85 BOTTOM OF WALL ELEVATION TOP OF WALL ELEVATION LIMIT OF PERMEABLE AGGREGATE c 411.52 S=2.0% GRADE BREAK NORTH MATCHLINE TO SHEET F120 (NOTE PLAN VIEW ORIENTATION CHANGE) SURVEY CONTOUR LINES GRADING NOTES 1.THE CONTRACTOR SHALL CALL AND NOTIFY DIGALERT AT 8-1-1 A MINIMUM OF 2 WORKING DAYS BEFORE DEMOLITION, DIGGING, OR GRADING OPERATIONS OCCUR. 2.PROVIDE CONSTANT SLOPES TO PREVENT PONDING WATER IN ALL PERIMETER AREAS. 3.STRIP FIELD AREA OF EXISTING SOD, ORGANIC MATERIALS, AND FIELD SECTION SAND MATERIALS AND DISPOSE OF OFF SITE. ALL EXCESS AND UNSUITABLE SOIL MATERIAL SHALL BE REMOVED AND DISPOSED OF OFF SITE. 4.HYDROSEED ALL DISTURBED LAWN AREAS AND RESTORE TO EXISTING OR BETTER CONDITION. 5.FURNISH AND INSTALL PERMEABLE FIELD BASE MATERIALS FOR THE ENTIRE SYNTHETIC TURF FIELD AREA INCLUDING 8 INCHES MINIMUM OF BASE COURSE PERMEABLE AGGREGATE AND 2 INCHES MINIMUM OF TOP COURES PERMEABLE AGGREGATE. 6.BACKFILL AND COMPACTE EXCAVATED AREAS RESULTING FROM DEMOLITION ACTIVITIES WITH SELECT FEILL TO 95% WITH 12” MAX. LIFTS. 7.THE CONTRACTOR SHALL NOTIFY THE ENGINEER IN THE EVENT OR DISCOVERY OF POOR SOILS, GROUNDWATER OR DISCREPANCIES IN THE EXISTING CONDITIONS AS NOTED ON THE PLANS. NOTE LEGEND 1. (INDICATES GENERAL CONSTRUCTION NOTE) 3.(INDICATES SPECIFIC CONSTRUCTION KEYNOTE) 48" GRADE TRANSITION AT FIELD EDGE DEVELOPMENT ENGINEERING HBray 06/24/2025 396.87 (EX) 396.90 (EX) 397.18 (EX) TW 398.28 TP 396.97 TW 398.61 TP 397.27 405.36 (EX) 405.28 (EX) 405.35 (EX) 405.42 (EX) 405.33 (EX) 402.17 (EX) 402.31 (EX) 405.27 (EX) 405.23 (EX) 405.35 (EX) 405.59 (EX) 405.37 (EX) 405.35 (EX) 405.38 (EX) 405.40 (EX) 405.23 (EX) 2. 2 % 1. 4 % 4. 8 % 3.2% 4.7 % 0.5% S D SD SD S D S D S D SD SD SD SD SD S D S D SD SD SDSDSD SD SD SD 30 0 ' 350 ' STORMWATER DETENTION SEE CIVIL 405 404 . 5 404 403 . 5 CLEANOUT (TYP.) CLEANOUT (TYP.) 403.05 403.39 403.39 405.00 405.00 405.00 405.83 405.00 405.00 INSERTA-TEE TAP CONNECTION EXIS T I N G 6 " C P E P S D C O L L E C T O R EXISTING 6" CPEP SD COLLECTOR153 LF EXISTING 6" CPEP SD COLLECTOR215 LF TW 405.21 BW 402.96 TW 405.21 BW 405.21 TW 399.00 BW 397.00 404.25 405.08 404.21 404.29 405.13 404.28 F222 4 F222 4 FLOW DIRECTION MATCHLINE TO SHEET F131 (NOTE PLAN VIEW ORIENTATION CHANGE) CITY OF RENTON IN COMPLIANCE WITH CITY OF RENTON STANDARDS R-4344 TE D - 4 0 - 4 3 4 4 PR : LU A : C: LU A 2 5 - 0 0 0 0 5 1 PR 2 5 - 0 0 0 0 1 8 C2 5 0 0 0 9 7 7 D.A. Hogan & Associates, inc. 1450 114th Ave. SE, Suite 225 Bellevue, WA 98004 206-285-0400 CIVIL CONSTRUCTION PERMIT 2/21/25 CIVIL CONSTRUCTION PERMIT RESUBMITTAL 4/14/25 CIVIL CONSTRUCTION PERMIT RESUBMITTAL 6/4/25 LINDBERGH HIGH SCHOOL BASEBALL DRAINAGE PLAN FIELD IMPROVEMENTS 26 DRAINAGE LEGEND EXISTING CATCH BASIN COLLECTOR INVERT ELEVATION INVERT ELEVATION END CAP EXISTING 6" PERF. CORR. POLY DRAIN TUBING EXISTING 6" OR 8" CPEP DRAIN COLLECTOR IE 414.30 CIE 413.00 DRAINAGE NOTES NOTE LEGEND 1. (INDICATES GENERAL CONSTRUCTION NOTE) 3.(INDICATES SPECIFIC CONSTRUCTION KEYNOTE) HAND EXCAVATE EXISTING DRAINAGE TRENCHES FOR EXISTING DRAINAGE PIPE INSPECTION, REPAIR, AND DRAINAGE AGGREGATE REPLACEMENT 1.SUBSURFACE DRAINAGE AND SITE STORMWATER INFRASTRUCTURE SHALL BE PRESERVED AND PROTECTED EXCEPT AS SPECIFICALLY AND EXPLICITLY DIRECTED BY THE ENGINEER. ALL EXISTING SYSTEM COMPONENTS ARE SCHEDULED FOR RE-USE. 2.FIELD SUBSURFACE DRAINAGE FINISH WORK MAY NOT BE PERFORMED PRIOR TO THE APPROVAL OF THE FIELD SUBGRADE ESTABLISHMENT. 3.FOLLOWING MASS EXCAVATION OF THE EXISTING OVER-BURDEN OF ROOT ZONE SANDS AND AGGREGATES AND APPROVAL OF THE SUBGRADE, LOCATE AND MARK WITH LATH AND FLAGGING EACH INDIVIDUAL FIELD SUBSURFACE DRAINAGE LATERAL AND REMOVE EXISTING DRAINAGE BACKFILL AGGREGATE SUFFICIENTLY TO INSPECT THE PIPE TO THE SPRINGLINE. PROTECT AND MAINTAIN TRENCH WALLS. 4.SURPLUS EXCAVATED SOIL AND AGGREGATE MATERIALS SHALL BE REMOVED FROM THE FIELD SUBGRADE PRIOR TO COMMENCING ON THE NEXT ADJACENT TRENCH. EXCAVATED MATERIAL MAY NOT REMAIN ON SUBGRADE. 5.PROVIDE A SMOOTH, EVEN SUBGRADE AFTER REMOVAL OF THE TRENCH MATERIAL. SUBGRADE TO BE COMPACTED TO 95%. LEAVE NO LOOSE MATERIAL ON THE SUBGRADE. SUBGRADE STRUCTURAL SOIL FABRIC PLACEMENT TO BE COORDINATED WITH THE COMPLETION OF DRAINAGE TRENCH CLEAN-UP, PLACEMENT OF TRENCH WALL FABRIC, AND BACKFILL WITH CLEAN, APPROVED DRAINAGE AGGREGATE. 6.WHERE DIRECTED, REMOVE EXISTING FIELD SUBSURFACE DRAINAGE LATERAL AND REPLACE WITH NEW AS FOLLOWS; A.EXCAVATION BELOW INVERT GRADE MUST BE ESTABLISHED TO A DEPTH SO AS TO PROVIDE FOR SPECIFIED PLACEMENT OF PEA GRAVEL BEDDING AT BOTTOM OF PIPE ELEVATION PRIOR TO LAYING THE PERFORATED PIPE. B.CONNECTION OF LATERALS TO COLLECTOR DRAINS SHALL BE MADE WITH A COMBINATION REDUCING TEE AND REDUCING SADDLE TEE. C.NO FOREIGN MATERIAL WILL BE PERMITTED INSIDE, ALONGSIDE, UNDER, OR ON TOP OF THE PERFORATED DRAIN PIPE. D.THE BACKFILL FOR ALL PERFORATED PIPE SHALL BE CLEAN WASHED PEA GRAVEL. REFER TO THE SPECIFICATIONS FOR THE GRADATION REQUIREMENTS. E.ALL TRENCHES TO HAVE BACKFILL MATERIAL "CROWNED" A MINIMUM OF 2" ABOVE SUBGRADE TO PROTECT FROM FOREIGN MATERIAL AND PROVIDE FOR EASE OF LOCATION IDENTIFICATION. CROWNS WITH FOREIGN MATERIAL CONTAMINATION SHALL BE REMOVED PRIOR TO PLACEMENT OF BASE AGGREGATE. F.DURING PLACEMENT OF SPECIFIED TRENCH BACKFILL, PIPE MUST BE HELD IN PLACE TO PREVENT DISPLACEMENT AND PROVIDE FOR ACHIEVING SPECIFIED INVERT ELEVATION. DO NOT DAMAGE PIPE OR ALLOW PIPE TO BE DISPLACED BY PLACEMENT OF BACKFILL MATERIAL. 7.CAP THE ENDS OF ALL LATERAL RUNS WHERE THE PIPE END IS EXPOSED. ALL OPEN ENDS DURING CONSTRUCTION ARE TO BE TEMPORARILY CAPPED OR PLUGGED. 8.NO TRUCKS OR EQUIPMENT WILL BE ALLOWED TO DRIVE OVER THE TOP OF THE TRENCHES EXCEPT TRACK-EQUIPPED MACHINERY UTILIZED IN SPREADING BASE AGGREGATE MATERIALS. BACKFILLED TRENCHES ARE TO BE STAKED AND FLAGGED 3' ABOVE GRADE AT MAXIMUM 30' SPACING. NORTH CLEANOUT DEVELOPMENT ENGINEERING HBray 06/24/2025 3 9 6 . 8 7 ( E X ) 3 9 6 . 9 0 ( E X ) 3 9 7 . 1 8 ( E X ) T W 3 9 8 . 2 8 T P 3 9 6 . 9 7 T W 3 9 8 . 6 1 T P 3 9 7 . 2 7 4 0 5 . 3 6 ( E X ) 4 0 5 . 2 8 ( E X ) 4 0 5 . 3 5 ( E X ) 4 0 5 . 4 2 ( E X ) 4 0 5 . 3 3 ( E X ) 4 0 2 . 1 7 ( E X ) 4 0 2 . 3 1 ( E X ) 4 0 5 . 2 7 ( E X ) 4 0 5 . 2 3 ( E X ) 4 0 5 . 3 5 ( E X ) 4 0 5 . 5 9 ( E X ) 4 0 5 . 3 7 ( E X ) 4 0 5 . 3 5 ( E X ) 4 0 5 . 3 8 ( E X ) 4 0 5 . 4 0 ( E X ) 4 0 5 . 2 3 ( E X ) 2.2 % 1. 4 % 4.8% 3 . 2 % 4.7% 0.5% 41 5 413 41 4 4 1 6 41 7 41 8 41 9 42 0 42 1 4 2 3 42 4 412 429.65 429.38 429.52 (EX)429.78 (EX) 430.45 (EX) 430.41 (EX) 430.22 (EX) 430.14 (EX)428.66 (EX) 428.64 (EX) 427.95 (EX) 427.80 (EX) 430.42 430.49 430.70 412.57 (EX) 412.51 (EX) 412.56 (EX) 412.57 (EX) 411.69 412.38 412.47 412.47 415.67 415.67 421.78 421.78 424.88 424.88 428.08 428.08 428.05 428.00 428.02 430.57 (EX) 430.64 (EX) 430.75 (EX) 430.70 (EX) TW 430.73 TW 430.66 430.58 430.86 (EX) 430.72 (EX) BW 429.44 BW 430.47 425.07 425.07 421.87 421.87 418.77 418.77 418.68 418.68 415.48 415.48 428.43428.62 428.09 428.291. 8 % 1. 5 % 0.7% 1. 4 % 1.3% 1.8% 1.8% 205' 20 5 ' SD SD SD SD SD SD SD 4 3 0 4 2 9 . 5 429 42 9 CLEANOUT (TYP.) 405.00 4 0 5 . 0 0 4 0 5 . 0 0 4 0 5 . 8 3 4 0 5 . 0 0 405.00 428.85 428.85 430.00 430.00 430.00 430.00 EX I S T I N G 6 " C P E P S D C O L L E C T O R 1 5 3 L F E X I S T I N G 6 " C P E P S D C O L L E C T O R EXIS T I N G 6 " C P E P S D C O L L E C T O R T W 4 0 5 . 2 1 BW 402.96 TW 405.21 BW 405.21 TW 399.00 BW 397.00 TW 430.73 BW 429.44 TW 430.39 BW 430.39 428.22 428.22 428.22 428.50 428.13 425.05 424.79 415.72 415.47 412.50 421.82 418.77 418.68 421.73 412.50 412.50 412.50 412.50 TW 430.66 BW 430.47 F222 4 CITY OF RENTON IN COMPLIANCE WITH CITY OF RENTON STANDARDS R-4344 TE D - 4 0 - 4 3 4 4 PR : LU A : C: LU A 2 5 - 0 0 0 0 5 1 PR 2 5 - 0 0 0 0 1 8 C2 5 0 0 0 9 7 7 D.A. Hogan & Associates, inc. 1450 114th Ave. SE, Suite 225 Bellevue, WA 98004 206-285-0400 CIVIL CONSTRUCTION PERMIT 2/21/25 CIVIL CONSTRUCTION PERMIT RESUBMITTAL 4/14/25 CIVIL CONSTRUCTION PERMIT RESUBMITTAL 6/4/25 LINDBERGH HIGH SCHOOL SOFTBALL DRAINAGE PLAN FIELD IMPROVEMENTS 27 MATCHLINE TO SHEET F130 (NOTE PLAN VIEW ORIENTATION CHANGE) DRAINAGE LEGEND DRAINAGE NOTES NOTE LEGEND 1. (INDICATES GENERAL CONSTRUCTION NOTE) 3.(INDICATES SPECIFIC CONSTRUCTION KEYNOTE) 1.SUBSURFACE DRAINAGE AND SITE STORMWATER INFRASTRUCTURE SHALL BE PRESERVED AND PROTECTED EXCEPT AS SPECIFICALLY AND EXPLICITLY DIRECTED BY THE ENGINEER. ALL EXISTING SYSTEM COMPONENTS ARE SCHEDULED FOR RE-USE. 2.FIELD SUBSURFACE DRAINAGE FINISH WORK MAY NOT BE PERFORMED PRIOR TO THE APPROVAL OF THE FIELD SUBGRADE ESTABLISHMENT. 3.FOLLOWING MASS EXCAVATION OF THE EXISTING OVER-BURDEN OF ROOT ZONE SANDS AND AGGREGATES AND APPROVAL OF THE SUBGRADE, LOCATE AND MARK WITH LATH AND FLAGGING EACH INDIVIDUAL FIELD SUBSURFACE DRAINAGE LATERAL AND REMOVE EXISTING DRAINAGE BACKFILL AGGREGATE SUFFICIENTLY TO INSPECT THE PIPE TO THE SPRINGLINE. PROTECT AND MAINTAIN TRENCH WALLS. 4.SURPLUS EXCAVATED SOIL AND AGGREGATE MATERIALS SHALL BE REMOVED FROM THE FIELD SUBGRADE PRIOR TO COMMENCING ON THE NEXT ADJACENT TRENCH. EXCAVATED MATERIAL MAY NOT REMAIN ON SUBGRADE. 5.PROVIDE A SMOOTH, EVEN SUBGRADE AFTER REMOVAL OF THE TRENCH MATERIAL. SUBGRADE TO BE COMPACTED TO 95%. LEAVE NO LOOSE MATERIAL ON THE SUBGRADE. SUBGRADE STRUCTURAL SOIL FABRIC PLACEMENT TO BE COORDINATED WITH THE COMPLETION OF DRAINAGE TRENCH CLEAN-UP, PLACEMENT OF TRENCH WALL FABRIC, AND BACKFILL WITH CLEAN, APPROVED DRAINAGE AGGREGATE. 6.WHERE DIRECTED, REMOVE EXISTING FIELD SUBSURFACE DRAINAGE LATERAL AND REPLACE WITH NEW AS FOLLOWS; A.EXCAVATION BELOW INVERT GRADE MUST BE ESTABLISHED TO A DEPTH SO AS TO PROVIDE FOR SPECIFIED PLACEMENT OF PEA GRAVEL BEDDING AT BOTTOM OF PIPE ELEVATION PRIOR TO LAYING THE PERFORATED PIPE. B.CONNECTION OF LATERALS TO COLLECTOR DRAINS SHALL BE MADE WITH A COMBINATION REDUCING TEE AND REDUCING SADDLE TEE. C.NO FOREIGN MATERIAL WILL BE PERMITTED INSIDE, ALONGSIDE, UNDER, OR ON TOP OF THE PERFORATED DRAIN PIPE. D.THE BACKFILL FOR ALL PERFORATED PIPE SHALL BE CLEAN WASHED PEA GRAVEL. REFER TO THE SPECIFICATIONS FOR THE GRADATION REQUIREMENTS. E.ALL TRENCHES TO HAVE BACKFILL MATERIAL "CROWNED" A MINIMUM OF 2" ABOVE SUBGRADE TO PROTECT FROM FOREIGN MATERIAL AND PROVIDE FOR EASE OF LOCATION IDENTIFICATION. CROWNS WITH FOREIGN MATERIAL CONTAMINATION SHALL BE REMOVED PRIOR TO PLACEMENT OF BASE AGGREGATE. F.DURING PLACEMENT OF SPECIFIED TRENCH BACKFILL, PIPE MUST BE HELD IN PLACE TO PREVENT DISPLACEMENT AND PROVIDE FOR ACHIEVING SPECIFIED INVERT ELEVATION. DO NOT DAMAGE PIPE OR ALLOW PIPE TO BE DISPLACED BY PLACEMENT OF BACKFILL MATERIAL. 7.CAP THE ENDS OF ALL LATERAL RUNS WHERE THE PIPE END IS EXPOSED. ALL OPEN ENDS DURING CONSTRUCTION ARE TO BE TEMPORARILY CAPPED OR PLUGGED. 8.NO TRUCKS OR EQUIPMENT WILL BE ALLOWED TO DRIVE OVER THE TOP OF THE TRENCHES EXCEPT TRACK-EQUIPPED MACHINERY UTILIZED IN SPREADING BASE AGGREGATE MATERIALS. BACKFILLED TRENCHES ARE TO BE STAKED AND FLAGGED 3' ABOVE GRADE AT MAXIMUM 30' SPACING. NORTH MATCHLINE TO SHEET F130 (NOTE PLAN VIEW ORIENTATION CHANGE) FLOW DIRECTION EXISTING CATCH BASIN COLLECTOR INVERT ELEVATION INVERT ELEVATION END CAP EXISTING 6" PERF. CORR. POLY DRAIN TUBING EXISTING 6" OR 8" CPEP DRAIN COLLECTOR IE 414.30 CIE 413.00 HAND EXCAVATE EXISTING DRAINAGE TRENCHES FOR EXISTING DRAINAGE PIPE INSPECTION, REPAIR, AND DRAINAGE AGGREGATE REPLACEMENT CLEANOUT DEVELOPMENT ENGINEERING HBray 06/24/2025 2. 2 % 1. 4 % 4. 8 % 3.2% 4.7 % 0.5% S D SD SD S D S D S D SD SD SD SD SD S D S D SD SD SDSDSD SD SD SD 30 0 ' 350 ' QCV-BB3 QUICK COUPLING VALVE & BOX (TYP.) QCV-BB2 QUICK COUPLING VALVE & BOX (TYP.) QCV-BB1 QUICK COUPLING VALVE & BOX (TYP.) QCV-BB4 QUICK COUPLING VALVE & BOX (TYP.) QCV-BB5 QUICK COUPLING VALVE & BOX (TYP.) QCV-BB6 QUICK COUPLING VALVE & BOX (TYP.) CO N N E C T N E W 2 " MAIN L I N E T O T H E EXIS T I N G M A I N L I N E A T EXIS T I N G G A T E V A L V E CONNECT TO NEW 2" MAINLINE TO THE EXISTING MAINLINE AT EXISTING GATE VALVE EXIS T I N G GAT E V A L V E IRRIGATION MAINLINE (TYP.) IRRIGATION MAINLINE (TYP.) IRRIGATION MAINLINE (TYP.) 2" MAINLINE 2" MAINLINE 2" MAINLINE 2" M A I N L I N E BALL VALVE (TYP.) BALL VALVE (TYP.) BALL VALVE (TYP.) F260 1 F260 1 F260 1 F260 1 F260 1 F260 1 F260 2 F260 2 F260 2 CITY OF RENTON IN COMPLIANCE WITH CITY OF RENTON STANDARDS R-4344 TE D - 4 0 - 4 3 4 4 PR : LU A : C: LU A 2 5 - 0 0 0 0 5 1 PR 2 5 - 0 0 0 0 1 8 C2 5 0 0 0 9 7 7 D.A. Hogan & Associates, inc. 1450 114th Ave. SE, Suite 225 Bellevue, WA 98004 206-285-0400 CIVIL CONSTRUCTION PERMIT 2/21/25 CIVIL CONSTRUCTION PERMIT RESUBMITTAL 4/14/25 CIVIL CONSTRUCTION PERMIT RESUBMITTAL 6/4/25 LINDBERGH HIGH SCHOOL BASEBALL IRRIGATION & WASHWATER PLAN FIELD IMPROVEMENTS 28 MATCHLINE TO SHEET F141 (NOTE PLAN VIEW ORIENTATION CHANGE) IRRIGATION LEGEND 1" QUICK COUPLER VALVE AND BOX SCH 40 PVC IRRIGATION MAIN LINE NORTH BALL VALVE IN INDIVIDUAL BOX DEVELOPMENT ENGINEERING HBray 06/24/2025 2.2 % 1. 4 % 4.8% 3 . 2 % 4.7% 0.5% 41 5 413 41 4 4 1 6 41 7 41 8 41 9 42 0 42 1 4 2 3 42 4 412 1. 8 % 1. 5 % 0.7% 1. 4 % 1.3% 1.8% 1.8% 205' 20 5 ' SD SD SD SD SD SD SD Q C V - B B 3 QUICK COUPLING VALVE & BOX (TYP.) QCV-BB4 Q U I C K C O U P L I N G VALVE & BOX (TYP.) QCV-BB5 Q U I C K C O U P L I N G V A L V E & B O X ( T Y P . ) CONNECT NEW 2" MAINLINE TO THE EXISTING MAINLINE AT EXISTING GATE VALVE QCV-SB1 QUICK COUPLING VALVE & BOX (TYP.) QCV-SB2 QUICK COUPLING VALVE & BOX (TYP.) QCV-SB3 QUICK COUPLING VALVE & BOX (TYP.) QCV-SB4 QUICK COUPLING VALVE & BOX (TYP.) QCV-SB5 QUICK COUPLING VALVE & BOX (TYP.) QCV-SB6 QUICK COUPLING VALVE & BOX (TYP.) EXISTING GATE VALVE IR R I G A T I O N M A I N L I N E (TYP.) 2" MAINLINE 2" MAINLINE 2" MAINLINE 2" MAINLINE B A L L V A L V E (T Y P . ) F 2 6 0 1 F2601 F2601 F 2 6 0 2 F260 1 F260 1 F260 1 F260 1 F260 1 CITY OF RENTON IN COMPLIANCE WITH CITY OF RENTON STANDARDS R-4344 TE D - 4 0 - 4 3 4 4 PR : LU A : C: LU A 2 5 - 0 0 0 0 5 1 PR 2 5 - 0 0 0 0 1 8 C2 5 0 0 0 9 7 7 D.A. Hogan & Associates, inc. 1450 114th Ave. SE, Suite 225 Bellevue, WA 98004 206-285-0400 CIVIL CONSTRUCTION PERMIT 2/21/25 CIVIL CONSTRUCTION PERMIT RESUBMITTAL 4/14/25 CIVIL CONSTRUCTION PERMIT RESUBMITTAL 6/4/25 LINDBERGH HIGH SCHOOL SOFTBALL IRRIGATION & WASHWATER PLAN FIELD IMPROVEMENTS 29 MATCHLINE TO SHEET F140 (NOTE PLAN VIEW ORIENTATION CHANGE) IRRIGATION LEGEND 1" QUICK COUPLER VALVE AND BOX SCH 40 PVC IRRIGATION MAIN LINE NORTH MATCHLINE TO SHEET F140 (NOTE PLAN VIEW ORIENTATION CHANGE) DEVELOPMENT ENGINEERING HBray 06/24/2025 LATERAL SPACING 15' TYP. FINISH GRADE INFILLED SYNTHETIC TURF SYSTEM 1" SUPPLEMENTAL PAD 2" TOP COURSE PERMEABLE AGGREGATE 7.5" BASE COURSE PERMEABLE AGGREGATE COMPACTED SUBGRADE EXISTING PEA ROCK DRAINAGE TRENCH PERMEABLE STRUCTURAL SOIL BEARING FABRIC EXISTING 4" PERF. CORR. POLY DRAIN TUBING EXISTING PEA ROCK DRAINAGE TRENCH REMOVE AND REPLACE TOP 2" OF PEA GRAVEL AT EACH TRENCH 12.5' WIDTH SOIL BEARING FABRIC PLACED EVENLY BETWEEN EXISTING DRAINAGE LINES FINISH GRADE 3.5" TOP COURSE PERMEABLE AGGREGATE 1.5" INFILLED SYNTHETIC TURF SYSTEM EXISTING COMPACTED SUBGRADE 7" EXISTING BASE COURSE PERMEABLE AGGREGATE EXISTING LATERAL PROPOSED SYNTHETIC TURF SECTIONEXISTING CRUSHED ROCK SECTION EXISTING LATERAL EXISTING COMPACTED SUBGRADE 8" EXISTING BASE COURSE PERMEABLE AGGREGATE 4" EXISTING CRUSHED ROCK SURFACING FINISH GRADE NOTE: EXPANSION JOINT TO BE INSTALLED AT ALL INTERFACE BETWEEN CONCRETE PAVING AND VERTICAL WALL OR EXISTING CONCRETE PAVING 2" 2" FINISH GRADE 4" CONCRETE PAVING LIGHT BROOM FINISH 6x6-6 GAUGE WELDED WIRE MESH 6" CRUSHED SURFACING TOP COURSE 4" BAND WITH SMOOTH FINISH CENTERED ON EXPANSION JOINT 3/8" EXPANSION JOINT WITH POLYURETHANE JOINT SEALANT EXPANSION JOINT EXPANSION JOINT SEALANT SUBGRADE COMPACTED TO 95% MIN. NOTE: EXPANSION JOINT TO BE INSTALLED AT ALL INTERFACE BETWEEN CONCRETE PAVING AND VERTICAL WALL OR EXISTING CONCRETE PAVING 4" CONCRETE PAVING LIGHT BROOM FINISH 6x6-6 GAUGE WELDED WIRE MESH 6" CRUSHED SURFACING TOP COURSE SUBGRADE COMPACTED TO 95% MIN. HAND-TOOLED WEAKENED PLANE JOINT, DEPTH EQUAL 25% OF THE SLAB THICKNESS B: CONCRETE PAVING WITH WEAKENED PLANE JOINT A: CONCRETE PAVEMENT AT EXPANSION JOINT 8" SEEDED LANDSCAPE RESTORATION ROOT ZONE; THOROUGHLY ROTOTILL 4" SOIL MIX AND 4" OF PREPARED SUBGRADE TO DEPTH OF 8" UNDISTURBED SITE SOIL 4" SOIL MIX 4" PREPARED SUBGRADE UNDISTURBED SITE SOIL CITY OF RENTON IN COMPLIANCE WITH CITY OF RENTON STANDARDS TE D - 4 0 - 4 3 4 4 D.A. Hogan & Associates, inc. 1450 114th Ave. SE, Suite 225 Bellevue, WA 98004 206-285-0400 R-4344 PR : LU A : C: LU A 2 5 - 0 0 0 0 5 1 PR 2 5 - 0 0 0 0 1 8 C2 5 0 0 0 9 7 7 CIVIL CONSTRUCTION PERMIT 2/21/25 CIVIL CONSTRUCTION PERMIT RESUBMITTAL 4/14/25 CIVIL CONSTRUCTION PERMIT RESUBMITTAL 6/4/25 LINDBERGH HIGH SCHOOL TYPICAL SECTIONS FIELD IMPROVEMENTS 30 NOT TO SCALE SYNTHETIC TURF FIELD SECTION F210 1 NOT TO SCALE BATTING CAGE SYNTHETIC TURF SECTION F210 2 NOT TO SCALE CONCRETE PAVING F210 3 NOT TO SCALE NATURAL TURF RESTORATION F210 4 DEVELOPMENT ENGINEERING HBray 06/24/2025 A 6" A =TOTAL DEPTH OF RUBBER PLATE B =DEPTH OF HOME PLATE MINUS DEPTH OF INFILL 4" PVC WEEP 29.5" B TOP OF HOME PLATE TO BE FLUSH WITH SYNTHETIC TURFHOME PLATE HOME PLATE BEVELED EDGE MAINTAIN 1/4" GAP AROUND TO FACILITATE REMOVAL ADHERE SYNTHETIC TURF BACK TO TOP OF FULLY CURE CONCRETE INFILLED SYNTHETIC TURF SUPPLEMENTAL PAD TOP COURSE AGGREGATE BASE COURSE AGGREGATE MAINTAIN 3" OF PERMEABLE AGGREGATE COMPACTED SUBGRADE EXISTING SOIL BEARING STRUCTURAL FABRIC F210 1 6"6" FAIR FOUL ORANGE SAFETY BASE FIRST BASE AT SOFTBALL FIELD ONLY, LOCATE ADJACENT INTO FOUL TERRITORY PRO-STYLE BASE FOR ALL OTHER BASES ANCHOR TOP PLATE MALE POST NOTE: PROVIDE PLUG WITH TURF TO FIT IN SLEEVE ANCHOR TOP PLATE FEMALE GROUND STAKE FOUL LINE PITCHING RUBBER 6"SQx24" SET CONCRETE COLLAR TO RECEIVE PLATE FLUSH TO ADJACENT INFIELD MIX MAINTAIN 1/4" CLEAR AROUND BASE COURSE PERMEABLE AGGREGATE COMPACTED SUBGRADE CONCRETE SYNTHETIC TURF TOP COURSE PERMEABLE AGGREGATE ADHERE SYNTHETIC TURF BACKING TO TOP OF CONCRETE 1" PVC DRAIN SUPPLEMENTAL PAD 1/4"1/4" 6-1/2" F210 1 ±18" WIDE 6" 2' 3'-6" 30" 18" BROWN INFILLED SYNTHETIC TURF FINISH GRADE AT TOP OF PITCHER'S RUBBER TO BE LEVEL 10" ABOVE FIELD FINISH GRADE 4" CONCRETE PAD UNDER SYNTHETIC TURF 3'-6" X 10'12:1 SLOPE FROM A POINT 6" IN FRONT OF THE PITCHER'S RUBBER TO A POINT 6' TOWARDS HOME PLATE PLAN VIEW 6" CENTER CIRCLE c c c FG +10" 8' FG +10" FG +0" R9' TO RADIUS POINT 12 : 1 4x4 RECYCLED PLASTIC TIMBER SURROUNDING CONCRETE PAD SYNTHETIC TURF EDGE ANCHOR AT PITCHER'S MOUND REMOVABLE TURF INSERT WITH VELCRO EDGES 7'-6"34" LEVEL PAD 5'-2" FG +10" FG +0" SECTION @ CONCRETE PAD 4" CONCRETE PAD BASE COURSE PERMEABLE AGGREGATE 4X4 RECYCLED PLASTIC TIMBER IN LENGTHS AS REQUIRED. #4 REBAR 2' O.C. BROWN SYNTHETIC TURF GREEN SYNTHETIC TURF SYNTHETIC TURF EDGE ANCHOR AT PITCHER'S MOUND 4X4 RECYCLED PLASTIC TIMBER IN LENGTHS AS REQUIRED. #4 REBAR 2' O.C. SYNTHETIC TURF EDGE ANCHOR AT PITCHER'S MOUND 1.50' C 9'-0" 6" 30" 4" 10' 34" BACK OF LEVEL PAD L F210 1 E F ELEVATION E PLAN VIEW F 12" E D SECTION MIN. 3" AT FENCE POSTS 12" 2.5" CLR C ELEVATION B PLAN VIEW ALTERNATE EXPANSION JOINT AND WEAKENED PLAN/CONTROL JOINT AT EACH POST. CONCRETE PAVING JOINTS TO ALIGN WITH ℄ OF FENCE POSTS WHERE INCLUDED. 12" 12" MIN. 3" MIN. 3" A SECTION C B C B TOOLED EDGE 0.5" 45° CHAMFER #4 REBAR CONTINUOUS #4 REBAR CONTINUOUS 3/8" IMPREGNATED FIBER BOARD AT ALL LOCATIONS, FULL DEPTH AT FENCE POST LOCATIONS 0.5" 45° CHAMFER CHAIN LINK FENCE TOOLED EDGE LOCATE (2) CONTINUOUS #4 BAR WITHIN THE BOTTOM 30% OF THE CURB MASS. PROVIDE ADEQUATE COVER. #4 REBAR CONTINUOUS 0.5" 45° CHAMFER FENCE POST FOOTING 3/8" IMPREGNATED FIBER BOARD AT ALL LOCATIONS, FULL DEPTH AT FENCE POST LOCATIONS CONTINUOUS CONC. FENCE POST LOCATE (2) CONTINUOUS #4 BAR WITHIN THE BOTTOM 30% OF THE CURB MASS. PROVIDE ADEQUATE COVER. A 2.5" CLR C 0.5" 45° CHAMFER #4 REBAR CONTINUOUS D CITY OF RENTON IN COMPLIANCE WITH CITY OF RENTON STANDARDS TE D - 4 0 - 4 3 4 4 D.A. Hogan & Associates, inc. 1450 114th Ave. SE, Suite 225 Bellevue, WA 98004 206-285-0400 R-4344 PR : LU A : C: LU A 2 5 - 0 0 0 0 5 1 PR 2 5 - 0 0 0 0 1 8 C2 5 0 0 0 9 7 7 CIVIL CONSTRUCTION PERMIT 2/21/25 CIVIL CONSTRUCTION PERMIT RESUBMITTAL 4/14/25 CIVIL CONSTRUCTION PERMIT RESUBMITTAL 6/4/25 LINDBERGH HIGH SCHOOL SITE DETAILS FIELD IMPROVEMENTS 31 NOT TO SCALE HOME PLATE F220 1 NOT TO SCALE BASE WITH ANCHOR F220 2 NOT TO SCALE SOFTBALL PITCHERS PLATE F220 4 NOT TO SCALE BASEBALL PITCHERS MOUND F220 5 NOT TO SCALE CONCRETE CURB & EXPANSION JOINT F220 3 DEVELOPMENT ENGINEERING HBray 06/24/2025 FINISH GRADE EXISTING CHAIN LINK FENCE ADJACENT SURFACE MAY VARY SYNTHETIC TURF EDGE ANCHOR EXISTING CONCRETE CURB F210 1 F221 4 SUPPLEMENTAL PAD TO MEET AND MATCH TOP OF EXISTING EDGE ANCHORFINISH GRADE INFILL MATERIAL TO BE FLUSH WITH TOP OF ADJACENT SURFACE A.REMOVE AND REGRADE EXISTING TOP COURSE PERMEABLE AGGREGATE; UNIFORMLY TRANSITION OVER 48" TO ACCOMMODATE FULL DEPTH OF SUPPLEMENTAL PAD TO THE EXISTING EDGE ANCHOR A INFILLED SYNTHETIC TURF (TYP.) SUPPLEMENTAL PAD TOP COURSE PERMEABLE AGGREGATE BASE COURSE PERMEABLE AGGREGATE NOTES: 1.THE PLASTIC EDGE ANCHOR MAY BE TEMPORARILY SET WITH POWER-LOADS PLACED AT THE CONTRACTORS OPTION TO ASSIST IN ESTABLISHING THE PROPER LINE AND GRADE. THIS TEMPORARY HARDWARE MAY REMAIN AFTER FINAL INSTALLATION. 2.THE CONTRACTOR MAY CHOOSE TO UTILIZE STEEL POWER-LOAD DRIVEN OR RAM-SET CONCRETE ANCHOR NAILS, MINIMUM SHANK DIAMETER 5/32", MINIMUM HEAD/WASHER DIAMETER 3/8", SUFFICIENT LENGTH TO INSURE A MINIMUM 2" EMBEDMENT. INDIVIDUAL ANCHORS SHALL DEVELOP A MINIMUM 450LB SHEAR, 350LB TENSION IN 4,000PSI CONCRETE AT 2" EMBEDMENT. 3.ONCE INITIAL LINE AND GRADE HAS BEEN ESTABLISHED, INSTALL THE SPECIFIED RAM-SET OR POWER-LOAD DRIVEN CONCRETE ANCHORING NAILS IN MANNER CONSISTENT WITH THE APPROVED MANUFACTURERS PRINTED INSTRUCTION AND THE SPECIFIED SPACING. 4.WEDGE ANCHOR TO BE SET AT MIDDLE 50% OF EACH BOARD. 30" O.C. MAX., 4-6" FROM ENDS. 5.MINIMUM REQUIREMENTS FOR CONCRETE ANCHOR NAIL INSTALLATION DEPTH OF EMBEDMENT: 2" OR AS RECOMMENDED BY THE ANCHOR SUPPLIER, WHICHEVER IS GREATER. HORIZONTAL SPACING: NO GREATER THAN 21" ON CENTER AND 6" FROM END OF ANY LENGTH OF LUMBER. STAGGER THE SPACING OF EACH ANCHOR UP AND DOWN WITHIN THE MIDDLE ONE-HALF THE FACE OF THE RECYCLED EDGE ANCHOR. 21" (TYP) 21" (TYP) 21" (TYP) MIDDLE 50% 6" ℄ UPPER 25% LOWER 25% WEDGE ANCHOR POWER LOAD/ RAM-SET INFILLED SYNTHETIC TURF (TYP.) (4) 3/4" MARINE GRADE PLYWOOD INSTALLED FOR RADIUS INDICATED #4 REBAR 2' O.C. FINISH GRADE GREEN SYNTHETIC TURF COMPACTED SUBGRADE BASE COURSE PERMEABLE AGGREGATE TOP COURSE PERMEABLE AGGREGATE BROWN SYNTHETIC TURF AT PITCHER'S MOUND, RADIUS PER PLAN F210 1 SUPPLEMENTAL PAD EXISTING CHAIN LINK FENCE MIN. 2 GALVANIZED STAPLES TO ANCHOR WOOD BOARD TO REBAR #5 REBAR 30" LONG, SPACED 24" ON CENTER, FULL PENETRATION INTO SUBGRADE (DO NOT CUT BAR) FINISH GRADE OF SYNTHETIC TURF TO BE FLUSH WITH TOP OF 2x6 BOARD GALVANIZED NAIL OR STAPLE SYNTHETIC TURF AND STRUCTURAL FABRIC TO EDGE ANCHOR INFILLED SYNTHETIC TURF (TYP.)F210 1 3.5" TOP COURSE PERMEABLE AGGREGATE EXISTING BASE COURSE PERMEABLE AGGREGATE 2x6 AND 2x4 EDGE ANCHOR; PROVIDE 14g GALVANIZED MENDING PLATE AT BUTT-SPLICES (3) 3" #10 SS PAN-HEAD SCREWS, 21" O.C. CITY OF RENTON IN COMPLIANCE WITH CITY OF RENTON STANDARDS TE D - 4 0 - 4 3 4 4 D.A. Hogan & Associates, inc. 1450 114th Ave. SE, Suite 225 Bellevue, WA 98004 206-285-0400 R-4344 PR : LU A : C: LU A 2 5 - 0 0 0 0 5 1 PR 2 5 - 0 0 0 0 1 8 C2 5 0 0 0 9 7 7 CIVIL CONSTRUCTION PERMIT 2/21/25 CIVIL CONSTRUCTION PERMIT RESUBMITTAL 4/14/25 CIVIL CONSTRUCTION PERMIT RESUBMITTAL 6/4/25 LINDBERGH HIGH SCHOOL SITE DETAILS FIELD IMPROVEMENTS 32 NOT TO SCALE EDGE ANCHOR AT EXISTING CURB F221 1 NOT TO SCALE SYNTHETIC TURF EDGE ANCHOR NOTE F221 4 NOT TO SCALE EDGE ANCHOR AT PITCHERS MOUND F221 2 NOT TO SCALE BATTING CAGE EDGE ANCHOR F221 3 DEVELOPMENT ENGINEERING HBray 06/24/2025 17.00" 60.50' @ BASEBALL 43.00' @ SOFTBALL 15.00" 7.50" 90.00' @ BASEBALL 60.00' @ SOFTBALL 90.00' @ BASEBALL 60.00' @ SOFTBALL 90.00' @ BASEBALL 60.00' @ SOFTBALL 15.00" 7.50" 15.00" 7.50" 24.00" 6.00" 8.50" 17.00" 90° 90° 2nd BASE LAYOUT POINT 2nd BASE LAYOUT POINTBASE WITH ANCHOR (TYP.) 3rd BASE LAYOUT POINT 3" FOUL LINE (TYP.) BASE WITH ANCHOR (TYP.) 1st BASE LAYOUT POINT 1st BASE LAYOUT POINT 3" FOUL LINE (TYP.) PITCHERS PLATE HOME PLATE HOME PLATE LAYOUT POINT 3rd BASE LAYOUT POINT CONCRETE OUTLINE HOME PLATE LAYOUT POINT F220 2 F220 2 F220 1 OUTFIELD SIGN SET GROUND SLEEVE FLUSH WITH TOP OF CONCRETE CURB 25' 3' GROUND SLEEVE 24" DIA. 5' DEEP CONCRETE FOOTING EXISTING OUTFIELD FENCING INSTALL FOUL POLE AS A TERMINAL POST IN OUTFIELD FENCE FOUL POLE: 5.5" O.D. PAINTED YELLOW SCH 40 GALVANIZED 2' FOUL TERRITORY FAIR (IN PLAY) ELEVATION FINISHED GRADE SURFACE VARIES EXISTING CURB AT OUTFIELD FENCE TO BE REMOVED AND REPLACED AS NEEDED FOR NEW CONCRETE FOOTING 200 PLAN VIEW OUTFIELD FENCING LINE POST FENCE FABRIC FOUL POLE INTEGRATED AS TERMINAL POST FOUL POLE FOOTING CONCRETE CURB FOUL FAIR IN PLAY OUT OF PLAY FOUL LINE FLAG: 1-1/2" X 11GA. MILD STEEL A36 FLATTENED EXPANDED SHEET 2"-4" CLEAR OF TOP RAIL COMPACTED BEDDING MATERIAL (PEA GRAVEL) 8" MIN UNDISTURBED SUBGRADE PLUG AND BLOCK OR CONTINUE PIPE 45° BEND CONCRETE COLLAR APPROVED WATERTIGHT CONNECTION COMPACTED SELECT BACKFILL MATERIAL Ø 2'-6" SECURE SYNTHETIC TURF TO CONCRETE COLLAR AND COVER WITH ADHESIVE INSTALL NON-ADHESIVE PAD PLUG WITH CONTRASTING SHADE OF TURF INTO HOLESEAST JORDAN IRON WORKS LOCKING RING AND COVER (OR APPROVED EQUAL) 2 STAINLESS STEEL CAP SCREWS. CUT HOLES IN TURF TO CLEAR FASTENING SCREWS INFILLED SYNTHETIC TURF APPROVED WATER TIGHT PLUG (TYP) INSTALL FENCE CAP AT ALL STADIUM 4' HT. FIELD PERIMETER FENCE SECTION CONTINUOUS, EXCEPT TERMINATE FENCE CAP AT TERMINAL POSTS POLYETHYLENE FENCE CAP (COLOR TO BE BLACK) SECURE WITH CABLE TIES, 2' O.C. TOP RAIL AT PERIMETER FENCE FIELD PERIMETER FENCING FENCE CAP FENCE POST MAX. 10'-0" 10 ' - 0 " S H O W N 2 1 1 15" O.C. GROMMET AND ZIP TIE INCLUDE MIDDLE SELVAGE 2 HOLD ALL SCREENS 12" UP FROM FINISHED GRADE 3 TERMINATE AT TENSION BAND AT POST 1 1 3 3 12" 15.00" GROMMET GROMMET GROMMET NOT TO SCALE BASE AND PLATE ANCHOR LAYOUT F222 1 NOT TO SCALE FOUL POLE F222 5 NOT TO SCALE CLEANOUT F222 4 NOT TO SCALE FENCE CAP F222 3 NOT TO SCALE WIND SCREEN F222 2 CITY OF RENTON IN COMPLIANCE WITH CITY OF RENTON STANDARDS TE D - 4 0 - 4 3 4 4 D.A. Hogan & Associates, inc. 1450 114th Ave. SE, Suite 225 Bellevue, WA 98004 206-285-0400 R-4344 PR : LU A : C: LU A 2 5 - 0 0 0 0 5 1 PR 2 5 - 0 0 0 0 1 8 C2 5 0 0 0 9 7 7 LINDBERGH HIGH SCHOOL SITE DETAILS FIELD IMPROVEMENTS 33 CIVIL CONSTRUCTION PERMIT 2/21/25 CIVIL CONSTRUCTION PERMIT RESUBMITTAL 4/14/25 CIVIL CONSTRUCTION PERMIT RESUBMITTAL 6/4/25 DEVELOPMENT ENGINEERING HBray 06/24/2025 TERMINAL OR CORNER POSTS 2-7/8" O.D. SCH.40 STEEL PIPE (OR AS SPECIFIED) MAX. 10'-0" POST CAP A 1-5/8" O.D. TOP RAIL (TYP.) 1-5/8" O.D. INTERMEDIATE RAIL (WHERE APPLICABLE) 10 ' - 0 " S H O W N SELVAGE 1" ABOVE TOP RAIL C 2" MESH, CHAIN LINK FABRIC, 9 GA. (FOR GALVANIZED FENCES), BOTTOM OF BOTTOM RAIL 1"-2" ABOVE FINISHED GRADE 2-3/8" O.D. LINE POSTS (OR AS SPECIFIED) 6 GA. ALUM. WIRE TIES @ 18" O.C. (TYP.) FOOTING DEPTH AND DIAMETER (SEE SCHEDULE) 6 GA. TIES ALONG TOP, INTERMEDIATE, & BOTTOM RAILS @ 18" O.C. (TYP.) TENSION WIRE (TYP.) TENSION BAR (TYP.) TENSION BAR BANDS/CLIPS @ 15" O.C. (TYP.) 1-5/8" O.D. BOTTOM RAIL (TYP.) FINISH GRADE SLOPE TO DRAIN WHERE NO CURB IS SPECIFIED CONCRETE FOOTING DEPTH AND DIAMETER (SEE SCHEDULE) COMPACTED SUBGRADE CURB WHERE SPECIFIED A TERMINAL POST CAP B LINE POST CAP TOP RAIL "EYE" TOP CAP C FABRIC SELVAGE KNUCKLED TOP & BOTTOM POST CAP B FOOTING DEPTH AND DIAMETER (SEE SCHEDULE) 4" 1.66" MID-RAIL WHERE SPECIFIED D FABRIC TIE TAIL OF TIE ALWAYS AGAINST POST & LOCKED UNDER "EYE" TOP 1.66" O.D. TOP & BOTTOM RAIL CHAIN LINK FENCE FABRIC, FINISHED WIRE SIZE AND MESH AS SPECIFIED 7G TENSION WIRE WHERE SPECIFIED SURFACE AND FINISH GRADE VARIES CONCRETE CURB CONCRETE FOOTING COMPACTED SUBGRADE OR UNDISTURBED SOIL CAST DOMED CAP SET SCREW F230 2 F230 2 F230 2 FENCING TYPE 4' HIGH FENCING CORNER POST TERMINAL POST LINE POST FOOTING DEPTH FOOTING DIAMETER TOP RAIL HT. INTERMEDIATE RAIL HTS. BOTTOM RAIL HT TENSION WIRE HTS. 2.875" OD 2.875" OD 2.375" OD 24" 12" 4' --- 1" 2' 10' HIGH WITH 15' NETTING 8.625" OD 8.625" OD 4.000" OD 7'-0" 30" 10' 5' 1" 2' 10' & 9' HIGH FENCING 4.000" OD 4.000" OD 2.875" OD 60" 12" 10' 5' 1" 2' FENCING NOTES: 1.ALL FENCING FABRIC SHALL BE 2" MESH NO. 9 GAUGE GALVANIZED STEEL WIRES EXCEPT FOR DESIGNATED SECTIONS OF THE BACKSTOP FENCING WHICH SHALL INCLUDE NO. 6 GAUGE GALVANIZED FINISHED STEEL WIRES. 2.ALL POSTS, RAILS, BRACES, POST TOPS, STRETCHER BARS, BANDS, ETC. SHALL BE GALVANIZED. 3.TENSION WIRES AND WIRE TIES SHALL BE GALVANIZED. 4.MAXIMUM POST SPACING: 10' ON CENTER. 5.ALIGN POSTS SO THAT FENCE FABRIC IS INSTALLED IN A CONTINUOUS, STRAIGHT LINE, REGARDLESS OF FENCE POST DIAMETER 6.ALL POSTS SHALL BE ASTM A53, GRADE B, SCHEDULE 40 UNLESS NOTED OTHERWISE. 7.BALL CONTROL NET SYSTEM POSTS ARE EXISTING AND INTENDED TO REMAIN. 7 4" FINISH GRADE NOTES: 1.INSTALL KICK PLATE ON ALL GATES WITHIN THE PATH STRETCHER BAR ACCESSIBLE GATE LATCH SWINGING GATE CHAIN LINK FENCE 4" O.D. POST TRUSS ROD STRETCHER BAR 1.66" O.D. FRAME (TYP.) SURFACE AND BASE VARIES COMPACTED SUBGRADE CONCRETE FOOTING (TYP.) CHAMFER KICK PLATE BOX AROUND PIPE GATE FRAME, FULL WELD, GALV. AFTER FABRICATION 12"x48" NOM. x3/16" GALV. KICK PLATE. 3/16" GALV. STEEL KICK PLATE BOX AND GATE FRAME SUPPORT; FULL FILET WELDS AT ALL JOINTS AND MATCH POINTS. PROVIDE (3) 3/16"Ø DRIP HOLES ALONG BOTTOM EDGE. F230 2 4" 12" 6" FINISH GRADE 4" SEE FENCING SCHEDULE FOR FOOTING DEPTH 1.67" O.D. GATE FRAME CHAIN LINK FENCE 4" O.D. POST TOP RAIL LATCH ASSEMBLY - INDUSTRIAL DOUBLE GATE STRETCHER BAR 4" O.D. POST BOTTOM RAIL TRUSS ROD DROP ROD & SLEEVE F230 2 2 12"1 12" CHAIN LINK FENCE GATE POST TYPICAL LATCH2 1/2"x1 1/2" 25 DIAMETER LEVER WELDED TO LATCH H:30" - 42" 3/8"X6" GALV. CARRIAGE BOLTS. 2 BOLTS PER BOARD @ ENDS AND CENTER POST. PEEN BOLT ENDS TO PREVENT REMOVAL CORNER POST TREATED AND STAINED 1" CLEAR FOOTING DEPTH AND DIAMETER (SEE SCHEDULE) 36"36" CONCRETE CURB (TYP) 24"24" CONCRETE CURBING (TYP) WELD ANGLE IRON TO POST. GRIND ALL WELDS SMOOTH. PAINT WITH 2 COATS GALVACON OR EQUAL. (TYP) 2X10 PRESSURE TREATED DOUGLAS FIR S4S. INSTALL BOARDS BUTTED TOGETHER WITHOUT GAPS. 24" CONCRETE CURBING (TYP) 2X10 PRESSURE TREATED DOUGLAS FIR S4S. INSTALL BOARDS BUTTED TOGETHER WITHOUT GAPS. 4" POST W/CAP 36" 1 1/2"X1/8"X2" ANGLE IRON (TYP) 24" 38" X 6" GALV. CARRIAGE BOLTS. 2 BOLTS PER BOARD @ ENDS AND CENTER POST. PEEN BOLT ENDS TO PREVENT REMOVAL WELD ANGLE IRON TO POST GRIND ALL WELDS SMOOTH. PAINT ANGLE WITH 2 COATS GALVACON OR EQUAL. (TYP) 36" REAR ELEVATION FRONT ELEVATION FOOTING DEPTH AND DIAMETER (SEE SCHEDULE) VINYL CLAD 1" PAD TO COVER STOP BOARDS. SECURELY ATTACH TO STOP BOARDS. 4" POST W/CAP F230 2 F230 2 CITY OF RENTON IN COMPLIANCE WITH CITY OF RENTON STANDARDS TE D - 4 0 - 4 3 4 4 D.A. Hogan & Associates, inc. 1450 114th Ave. SE, Suite 225 Bellevue, WA 98004 206-285-0400 R-4344 PR : LU A : C: LU A 2 5 - 0 0 0 0 5 1 PR 2 5 - 0 0 0 0 1 8 C2 5 0 0 0 9 7 7 CIVIL CONSTRUCTION PERMIT 2/21/25 CIVIL CONSTRUCTION PERMIT RESUBMITTAL 4/14/25 CIVIL CONSTRUCTION PERMIT RESUBMITTAL 6/4/25 LINDBERGH HIGH SCHOOL FENCING DETAILS FIELD IMPROVEMENTS 34 NOT TO SCALE CHAIN LINK FENCING ELEVATION & SECTION F230 1 NOT TO SCALE CHAIN LINK SCHEDULE F230 2 NOT TO SCALE SINGLE SWING GATE F230 4 NOT TO SCALE DOUBLE SWING GATE F230 5 NOT TO SCALE GATE LATCH F230 3 NOT TO SCALE STOPBOARDS F230 6 DEVELOPMENT ENGINEERING HBray 06/24/2025 1/2 ON-CENTER DISTANCE (18" MAX NET CABLE SAG) ℄ ℄ KNOTLESS 1.75" SQ. NYLON BALL CONTROL NETTING (NEW) 12"MIN, 18"MAX SAG AT CENTER OF CABLE 6"9" 3 A B C D E B B 6" TO LINE OR END POST 9" TO END POST D E F G B 3" MAX. 12" -15" O.C. H F D 3 H 3 G I B G D 6 12"-15" O.C. A EYE BOLT LOCATED NEAR TOP OF POLE ASSEMBLY. PLACEMENT TO ACCOUNT FOR POTENTIAL OF UP TO 18" OF SAG IN THE TOP SUPPORT CABLE AT 70LBF TENSION WITH THE NETTING IN PLACE. MAX SPACING BETWEEN HORIZONTAL CABLE ENDS 120LF B GALVANIZED OR STAINLESS STEEL THREADED MASTER LINK CARABINER OR APPROVED EQUAL, 1/2" x1-1.5" PROVIDE HORIZONTAL HARDWARE WITH APPROVED BLACK FINISH. C GALVANIZED STEEL THIMBLE SIZED FOR THE SPECIFIED WIRE ROPE; USE AT ALL CABLE TERMINATIONS. D GALVANIZED STEEL WIRE ROPE, 5/16"Ø. E WIRE ROPE CONNECTOR, U-BOLT TYPE. MIN. TWO PER CONNECTION OR AS NEEDED. F VINYL TAPE TRIPLE WRAP ALL CUT WIRE ENDS. G PRE-FABRICATED BALL CONTROL NET ASSEMBLY TO BE PROVIDED WITH A CONTINUOUS 5/8 "Ø NYLON ROPE BORDER. H BLACK VINYL OR POLYESTER SNAP-CLIP FOR VERTICAL CABLE-TO-ROPE CONNECTIONS ONLY I GALVANIZED OR STAINLESS STEEL TURNBUCKLE, 1/2 " x 12". 1 TOP CORNER; EYE BOLT SIZED TO ACCOMMODATE BOTH THE LIMIT ON GAP BETWEEN THE POLE AND THE VERTICAL CABLE AND THE CONNECTING LINKS FOR BOTH THE VERTICAL AND HORIZONTAL SUPPORT CABLES. PROVIDE (1) TURNBUCKLE AT EACH END OF EACH CABLE. (NEW) 2 TOP EDGE OF BALL CONTROL NET ASSEMBLY HELD TO THE SUPPORT CABLE WITH GALVANIZED OR STAINLESS STEEL OR ALUMINUM THREADED LINK, SNAP LINK, OR CARABINER-TYPE CONNECTOR WITH APPROVED BLACK FINISH. SIZE TO ALLOW SPACING NO LESS THAN 12" O.C. BUT NO GREATER THAN 21" O.C. TO REDUCE ROPE BORDER SAG BETWEEN CONNECTIONS. (NEW) 3 LOOSE VERTICAL CONNECTIONS TO BE VIA BLACK VINYL OR POLYESTER SNAP-CLIP SPACED 12"-15" O.C. 4 BOTTOM VERTICAL SUPPORT CABLE CONNECTION TO INCLUDE A TURNBUCKLE FOR ADJUSTMENT. 5 BALL CONTROL NET ASSEMBLY BOTTOM EDGE CONNECTION TO BE VIA HEAVY DUTY, UV-RESISTANT, NYLON ZIP TIE 12"-15" O.C. DIRECTLY TO CHAIN LINK FABRIC BELOW THE TOP RAIL. CLF FABRIC TO BE INSTALLED ON THE FIELD SIDE OF THE FRAMEWORK. BALL CONTROL NET TO BE SECURED TO THE FIELD SIDE OF THE FINISHED CHAIN LINK FENCE ASSEMBLY BELOW THE TOP RAIL. (NEW) 6 MAIN VERTICAL SUPPORT CABLE CONNECTION TO POLE AT 12' - 15' O.C., MATCH TOP TAB OR FLANGE A. (NEW) BALL CONTROL NETTING ASSEMBLY TOP CORNER CABLE & RIGGING TOP EDGE SUPPORT (NEW) VERTICAL EDGE SUPPORT (NEW) VERTICAL CABLE RIGGING CONNECTION @ CHAIN LINK FENCE (NEW) HARDWARE NOTES: CONNECTION NOTES: NOT TO SCALE NOT TO SCALE NOT TO SCALE NOT TO SCALE NOT TO SCALENOT TO SCALE B C D E F GALVANIZED 9 GAUGE x2" MESH CHAIN LINK FABRIC NETTING LINE POST 10.0' O.C. TYP AT ALL FENCE POSTS KNOTLESS 1.75" SQ. NYLON BALL CONTROL NETTING (NEW) 10' HT. CHAIN LINK FENCING 15' HT. NETTING NETTING POSTS @ 20'-0" OR 30' 0" O.C. H 3 MAX 160LF CABLE A 25HT. B G D INTERMEDIATE NET SUPPORT (NEW) NOT TO SCALEG H 3 I I (INCLUDE 1 TURNBUCKEL MIN., 2 FOR SPANS EXCEEDING 30') (INCLUDE 1 TURNBUCKEL MIN., 2 FOR SPANS EXCEEDING 30') END POST AND LINE POST SIZE PER SCHEDULE SEE TOP CORNER CABLE & RIGGING INSET 1 (NEW)SEE TOP EDGE SUPPORT INSET 2 SEE INTERMEDIATE NET SUPPORT INSET. INSTALL 5' O.C. VERTICAL 6 (NEW) SEE VERTICAL CABLE RIGGING INSET 4 SEE CONNECTION AT CHAIN LINK FENCE INSET 5 (NEW) ALL FABRIC SELVAGE TO BE KNUCKLED FENCE LINE POST GALVANIZED 9 GAUGE x2" MESH CHAIN LINK FABRIC 1 REMOVE EXISTING NETTING AND CONNECTING HARDWARE & DISPOSE. 2 EXISTING POSTS, RIGGING, AND RIGGING CONNECTION HARDWARE REMAINS. 3 ADD NEW VERTICAL CABLE SUPPORTS AS SHOWN. 4 REPLACE NETTING USING THE CONNECTION HARDWARE TYPE AND CONDITIONS NOTED. GENERAL NOTES: CITY OF RENTON IN COMPLIANCE WITH CITY OF RENTON STANDARDS TE D - 4 0 - 4 3 4 4 D.A. Hogan & Associates, inc. 1450 114th Ave. SE, Suite 225 Bellevue, WA 98004 206-285-0400 R-4344 PR : LU A : C: LU A 2 5 - 0 0 0 0 5 1 PR 2 5 - 0 0 0 0 1 8 C2 5 0 0 0 9 7 7 CIVIL CONSTRUCTION PERMIT 2/21/25 CIVIL CONSTRUCTION PERMIT RESUBMITTAL 4/14/25 CIVIL CONSTRUCTION PERMIT RESUBMITTAL 6/4/25 LINDBERGH HIGH SCHOOL BALL CONTROL NET REPLACEMENT DETAILS FIELD IMPROVEMENTS 35NOT TO SCALE BALL CONTROL & CABLE-FENCING & NETTING DETAIL F231 1 DEVELOPMENT ENGINEERING HBray 06/24/2025 8.00' 9.00' 0.50' (TYP) 30.00' 40.00' 12" CONCRETE CURB 5' SINGLE SWING GATE FENCING WITH NETTING 5' OPENING (NO LEAF) EXPANSION JOINT 4" CONCRETE PAD MEDIUM BROOM FINISH HOME PLATE 9' FENCING WITH 6 GAUGE FABRIC F240 6 F230 4 TOP OF FENCE POSTS FOUNDATION @ FG-1.5 (TYP.)12"W CONCRETE CURB/WALL (3rd BASE SOFTBALL, 1st BASE BASEBALL)F240 5 2.5" 3/8" HARDBOARD @ EXPANSION JOINT CENTERLINE OF DUGOUT SLAB #4 REBAR CONTINUOUS EXCEPT AT EXPANSION JOINTS 20'0" O.C. 2" (TYP.) 2.5" CONCRETE PAD MEDIUM BROOM FINISH 6" 3-3/8" F.V. 24 GAUGE ZINC-AUME FLASHING, PRE-FINISHED 1-1/2" F.V. 3" 1" 24 GAUGE ZINC-AUME CLEAT, PRE-FINISHED 20 GAUGE BARE GALVANIZED FLAT STRAP ROOF PANEL 24 GAUGE ZINC-ALUME Z-FURRING, PRE FINISHED, INSTALLED BETWEEN PANEL RIBS EDPM WASHERED GALVANIZED TEK3 SCREWS @ 24" O.C. INTO Z-FURRING 20 GAUGE BARE GALVANIZED CLIP (3) PER PANEL 24 GAUGE ZINC-ALUME FLASHING, PRE-FINISHED GALVANIZE METAL TO WOOD SELF-TAPPING SCREWS @ 6' O.C. 12" DRIPLINE OF FLASHING AND ROOFLINE SHALL BE FLUSH WITH PLANE OF FENCE FABRIC FENCE FABRIC 3-3/8" F.V. F.V. ROOF SECTION ROOF FRONT VIEW 24 GAUGE ZINC-AUME FLASHING, PRE-FINISHED FENCE POST ROOF PANEL 20 GAUGE BARE GALVANIZED CLIP (3) PER PANEL 18 GAUGE BN-36 DECKING PANEL SET PANEL INTO SEALANT @ FLASHING 20 GAUGE BARE GALVANIZED FLAT STRAP EPDM WASHERED GALVANIZED TEK3 SCREWS 6" O.C. 24 GAUGE ZINC-AUME FLASHING, PRE-FINISHED "COOL WALNUT" TREATED 4x8 20 GAUGE BARE GALVANIZED CLIP 20 GAUGE BARE GALVANIZED CLIP (3) PER PANEL EPDM WASHERED GALVANIZED TEK3 SCREWS 6" O.C. 3/16" 1/8"3" TREATED 4x8 SIMPSON HUC48 ⅊ 3/16 x 8 x 5" WIDE 1/8" 1/8"2TREATED 4x8 3/16 x 4 x 4 CAP ⅊ BEAM ONE SIDE ONLY: SIMPSON BC40 BEAM BOTH SIDES: SIMPSON CCOQ44 ROOF ELEVATION @ FRONT OF DUGOUT ROOF ELEVATION @ INTERMEDIATE FENCE POSTS FENCE TOP RAIL #4 REBAR TIED TO EACH SIDE OF FENCE POSTS 6"2" CLR 9' FENCE, 6 GAUGE TREATED 4x8 ROOF SUPPORT (DF#2/HF#1) 6" #4 REBAR 2" CLR. CONCRETE FOOTING (FOR FOOTING DEPTH AND DIAMETER SEE FENCING SCHEDULE) BASE AGGREGATE TREATED 4x8 ROOF SUPPORT (DF#2/HF#1) 10' CHAIN LINK FENCE FINISH GRADE OF INFIELD TO BE FLUSH WITH DUGOUT SLAB AND CURBING CONCRETE PAD PLAYERS BENCH METAL ROOF EDGE SLOPE CONCRETE CURB INFILLED SYNTHETIC TURF 1.5 12 PRE-PAINTED 24 GA HR36 METAL ROOF PANELS ON 20 GA. GALVANIZED/POWDER-COATED CORRUGATED METAL DECK. SECURE METAL DECK TO FENCE RAILS WITH EPDM WASHERED GALVANIZED TEK3 SCREWS AT 6" OC 12" COORDINATE LOCATION OF BENCH FOOTINGS TO NOT CONFLICT WITH FENCE POST FOOTINGS 96" F240 2 F230 1 F210 1 F240 4 CONCRETE CURB/WALLF240 5 CONCRETE FENCE FOOTING FABRIC 18" BOTTOM RAIL FABRIC 1" 18" MIN FINISH GRADE 95% COMPACTED SUBGRADE 6x6x10/10 W.W.M CONCRETE FOOTING ALLOW ONLY ENOUGH SPACE FOR FORMS 3" CONC. SURFACE TO HAVE FINE BROOM FINISH BROOM FINISH TO BE IN DIRECTION OF RUN-OFF. STEEL TROWEL EDGES W/ 1/2" RADIUS. ALL ALUMINUM PCTS PLAYER BENCH AND FITTING MFG: OUTDOOR ALUMINUM PCTS 21' OR EQUAL W/2" SQ.. GALV. TUBE DU G O U T F E N C E OR W A L L S=1% 6" 12" DIAM. CONCRETE FOOTING CONCRETE CURB/WALLF240 5 #4 REBAR 9" O.C. VERT./HORIZ. TIED TO EACH SIDE OF FENCE POSTS 12" W CONCRETE CURB/WALL (3rd BASE SOFTBALL, 1st BASE BASEBALL) FINISHED GRADE AT CONCRETE WALK / LANDSCAPE 9.0' (TYP.) 2.5' MAX. 3.0' MIN. 3.0' MIN.TOTAL WALL HEIGHT TO BE LESS THAN 3'11"'#4 REBAR 9" O.C. VERT./HORIZ. TIED TO EACH SIDE OF FENCE POSTS 1.5' MIN. CHAIN LINK FENCE (TYP.) FENCE POST FOOTING UNDERNEATH CURB WALL F230 1 NOTE ADDITIONAL POST LENGTH REQUIREMENTS CITY OF RENTON IN COMPLIANCE WITH CITY OF RENTON STANDARDS TE D - 4 0 - 4 3 4 4 D.A. Hogan & Associates, inc. 1450 114th Ave. SE, Suite 225 Bellevue, WA 98004 206-285-0400 R-4344 PR : LU A : C: LU A 2 5 - 0 0 0 0 5 1 PR 2 5 - 0 0 0 0 1 8 C2 5 0 0 0 9 7 7 CIVIL CONSTRUCTION PERMIT 2/21/25 CIVIL CONSTRUCTION PERMIT RESUBMITTAL 4/14/25 CIVIL CONSTRUCTION PERMIT RESUBMITTAL 6/4/25 LINDBERGH HIGH SCHOOL DUGOUT DETAILS FIELD IMPROVEMENTS 36 NOT TO SCALE DUGOUT - PLAN VIEW F240 1 NOT TO SCALE CONCRETE DUGOUT EXPANSION JOINT F240 6 NOT TO SCALE DUGOUT ROOF EDGE F240 4 NOT TO SCALE DUGOUT SECTION F240 3 NOT TO SCALE PLAYERS BENCH DETAIL F240 2 NOT TO SCALE DUGOUT RETAINING WALL SECTION F240 5 DEVELOPMENT ENGINEERING HBray 06/24/2025 HOME PLATE BASEBALL BULLPEN MOUND 1st BASELINE BULLPEN 60.50' 132°13.42' 1.17' 11.87' BASEBALL BULLPEN MOUND 135°14.11' 0.93' 7.00' HOME PLATE 3rd BASELINE BULLPEN 12" CONCRETE RETAINING CURB 18.00' 10.00' 10.00' 7.09' F250 3 F250 3 SYNTHETIC TURF EDGE ANCHOR (TYP.) SYNTHETIC TURF EDGE ANCHOR (TYP.) 18.00' 11.49' REMOVABLE TURF INSERT WITH VELCRO EDGE 60.50' REMOVABLE TURF INSERT WITH VELCRO EDGE 12" CONCRETE RETAINING CURB HOME PLATE INLAID PITCHING PLATE 43.00' 5.00' INLAID HOME PLATE 1.38' CLR. 0.17' CLR. EXPANSION JOINT BEHIND POST ±8" ±8"x10" BULLPEN MOUND BUNKER 12"x12" CONCRETE CURB 2" FENCE POST 3/4-1" CHAMFER STRIP (REMOVE WITH FORM WORK) 2" POST @ FENCE LINE 4" POST @ FENCE LINE FENCE LINE ℄℄ EXPANSION JOINT CURB 2"Ø 4"Ø 1 1 NOTES: 1.3/4"- 1" CHAMFER STRIP CAULKED IN PLACE TIGHT TO FENCE POST DURING FORM CONSTRUCTION. FINISHED GRADE FINISHED GRADE +0.83' (10" MOUND HT.) 6.00'2.83'5.17'4.00' F210 1 R9' F220 5 FG +0" FG +10" LIMIT OF CONCRETE WALL CONCRETE CURB BULLPEN MOUND BEYOND 4" FENCE POST 2" FENCE POST WALL C PLAN VIEW (SEE DETAIL ABOVE) INSET WALL C PLAN VIEW WALL C ELEVATION SEE INSET TO THE ABOVE FG +48" 4' HT. CHAINLINK FENCE (TYP.) FG +10" FG +0" SECTION @ CONCRETE PAD SYNTHETIC TURF FIELD 4X4 RECYCLED PLASTIC TIMBER IN LENGTHS AS REQUIRED. #6 REBAR 4' O.C. 4" CONCRETE PAD BASE COURSE PERMEABLE AGGREGATE 4X4 RECYCLED PLASTIC TIMBER IN LENGTHS AS REQUIRED. #6 REBAR 4' O.C. BROWN INFILLED SYNTHETIC TURF FINISH GRADE AT TOP OF PITCHER'S RUBBER TO BE LEVEL 10" ABOVE FIELD FINISH GRADE 4" CONCRETE PAD UNDER SYNTHETIC TURF 3'-6" X 10'12:1 SLOPE FROM A POINT 6" IN FRONT OF THE PITCHER'S RUBBER TO A POINT 6' TOWARDS HOME PLATE PLAN VIEW @ 3rd BASE BULLPEN CENTER CIRCLE c c FG +10" FG +10" FG +0" 12 : 1 4x4 RECYCLED PLASTIC TIMBER SURROUNDING CONCRETE PAD SYNTHETIC TURF EDGE ANCHOR AT PITCHER'S MOUND REMOVABLE TURF INSERT WITH VELCRO EDGES BACK OF LEVEL PAD ALL SLOPES SYMMETRICAL/TANGENT SEE PITCHER'S MOUND DETAIL FOR ALL DIMENSIONS GB GB 12" CONCRETE CURB SEE INSET TO RIGHT 18.00' LIMIT OF CURB BEYOND CURB ABOVE EXISTING CURB, SEE BELOW CITY OF RENTON IN COMPLIANCE WITH CITY OF RENTON STANDARDS TE D - 4 0 - 4 3 4 4 D.A. Hogan & Associates, inc. 1450 114th Ave. SE, Suite 225 Bellevue, WA 98004 206-285-0400 R-4344 PR : LU A : C: LU A 2 5 - 0 0 0 0 5 1 PR 2 5 - 0 0 0 0 1 8 C2 5 0 0 0 9 7 7 CIVIL CONSTRUCTION PERMIT 2/21/25 CIVIL CONSTRUCTION PERMIT RESUBMITTAL 4/14/25 CIVIL CONSTRUCTION PERMIT RESUBMITTAL 6/4/25 LINDBERGH HIGH SCHOOL BULLPEN DETAILS FIELD IMPROVEMENTS 37 NOT TO SCALE BASEBALL BULLPEN PLAN VIEW F250 1 NOT TO SCALE SOFTBALL BULLPEN PLAN VIEW F250 2 NOT TO SCALE BASEBALL BULLPEN MOUND F250 3 DEVELOPMENT ENGINEERING HBray 06/24/2025 20' 12' HT. 14' EXISTING CONCRETE PAVING GLUE/ADHERE TURF ON TOP OF CONCRETE FOOTING (TYP.) 10' HT. CHAIN LINK FENCE IN CONCRETE CURB FOOTING FOR NETTING (TYP.) INFILLED SYNTHETIC TURF (TYP.) NETTING (TYP.) PREFABRICATED BATTING CAGE WITH NETTING EXISTING BASE COURSE PERMEABLE AGGREGATE EXISTING COMPACTED SUBGRADE EXISTING NATURAL TURF 40" x 12" CONCRETE FOOTING FOR 3' GROUND SLEEVE F210 2 EDGE ANCHOR IN CONCRETE CURB (TYP.)F221 3 69.92' 67.30' 79.66' BA T T I N G C A G E SE C T I O N 40.00' 14' POLE TO POLE INLAID PITCHERS PLATE (TYP.) INLAID HOME PLATE (TYP.) INFILLED SYNTHETIC TURF (TYP.)EXISTING CHAIN LINK FENCE (TYP.) EXISTING 5' SINGLE SWING GATE (TYP.) EXISTING 5' SINGLE SWING GATE (TYP.) 54.22' 50.50' 59.58' F210 2 SOFTBALL BATTING CAGE F2 5 0 # BASEBALL BATTING CAGE CITY OF RENTON IN COMPLIANCE WITH CITY OF RENTON STANDARDS TE D - 4 0 - 4 3 4 4 D.A. Hogan & Associates, inc. 1450 114th Ave. SE, Suite 225 Bellevue, WA 98004 206-285-0400 R-4344 PR : LU A : C: LU A 2 5 - 0 0 0 0 5 1 PR 2 5 - 0 0 0 0 1 8 C2 5 0 0 0 9 7 7 LINDBERGH HIGH SCHOOL BATTING CAGE DETAILS FIELD IMPROVEMENTS 38 NOT TO SCALE BATTING CAGE PLAN VIEW F251 1 NOT TO SCALE BATTING CAGE SECTION F251 2 CIVIL CONSTRUCTION PERMIT 2/21/25 CIVIL CONSTRUCTION PERMIT RESUBMITTAL 4/14/25 CIVIL CONSTRUCTION PERMIT RESUBMITTAL 6/4/25 DEVELOPMENT ENGINEERING HBray 06/24/2025 18" FINISH GRADE NOTES: 1 BRASS QUICK COUPLING VALVE 2 RUBBER CAP 3 GALVANIZED NIPPLE 4 STAINLESS STEEL CLAMP 5 SPORTSFIELD SPECIALTIES TURFCOOL OR APPROVED EQUAL VALVE BOX WITH REMOVABLE LID 6 CLEAN PEA GRAVEL 4"-6" DEPTH 1 2" 3 4 4 5 #31" MIPT x MALE ACME INLET 1" FEMALE ACME x MALE ACME 90 PVC MAINLINE 6 1" SWING ARM WITH 12" LAY LENGTH 1" FEMALE ACME x MIPT INFILLED SYNTHETIC TURF 1" SCH 40 STREET ELL 2 F210 1 24" MIN. MAIN LINE TRENCH 6" TYP MIN. 12" WIDE TRENCH (OR AS REQUIRED TO ALLOW ADEQUATE COMPACTION OF BACKFILL)FINISH GRADE INFILLED SYNTHETIC TURF FIELD DETECT-A-TAPE (BLUE) 6" ABOVE PIPE CLEAN, COMPACTED, SUITABLE NATIVE BACKFILL SCH 40 PVC MAIN LINE BUNDLE CONTROLLER WIRES UNDER MAIN LINE ON OPPOSITE SIDE FROM SWING JOINTS (WHEN LATERAL & MAIN SHARE THE SAME TRENCH) NOTES: TAPE WIRES PER SPEC. DO NOT TAPE BUNDLED WIRES TO MAIN LINE. F210 1 INFILLED SYNTHETIC TURF FINISH GRADE NOTES: 1 BRASS BALL VALVE, THREADED INLET/OUTLET, SIZED PER THE DRAWINGS OR ASSOCIATED INLET-SIDE PIPE 2 BRASS UNION 3 BRASS NIPPLE 4 SCHEDULE 80- PVC BUSHING, SxT 5 MIN. 12" HORIZONTAL & VERTICAL OFFSET FROM MAINLINE 6 SPORTSFIELD SPECIALTIES TURFCOOL OR APPROVED EQUAL VALVE BOX WITH REMOVABLE LID 6 PVC MAINLINE (TYP.) SCH.80 PVC TEE, FITTINGS & ADAPTERS (AS REQUIRED) 5 SCH. 40 PVC OUT BRASS 1 33 2 2 4 4 18" 24" 18" F210 1 CITY OF RENTON IN COMPLIANCE WITH CITY OF RENTON STANDARDS TE D - 4 0 - 4 3 4 4 D.A. Hogan & Associates, inc. 1450 114th Ave. SE, Suite 225 Bellevue, WA 98004 206-285-0400 R-4344 PR : LU A : C: LU A 2 5 - 0 0 0 0 5 1 PR 2 5 - 0 0 0 0 1 8 C2 5 0 0 0 9 7 7 CIVIL CONSTRUCTION PERMIT 2/21/25 CIVIL CONSTRUCTION PERMIT RESUBMITTAL 4/14/25 CIVIL CONSTRUCTION PERMIT RESUBMITTAL 6/4/25 LINDBERGH HIGH SCHOOL WASHWATER DETAILS FIELD IMPROVEMENTS 39 NOT TO SCALE QUICK COUPLING VALVE & BOXES F260 1 NOT TO SCALE TRENCHING FOR MAINLINE PIPE F260 3 NOT TO SCALE BALL VALVE IN TURFCOOL BOX F260 2 DEVELOPMENT ENGINEERING HBray 06/24/2025 SECTION A-A POST DETAIL NOTES: 1.NUMBER OF STEPS SHALL SUIT INDIVIDUAL CONDITIONS, WITH TREAD AND RISER DIMENSIONS TO SUIT THE GRADE. 2.RISERS SHALL BE OF EQUAL HEIGHT AND TREAD PER PLAN. 3.ALL STEPS SHALL HAVE RAILINGS (BOTH SIDES AND CENTER, IF APPLICAPBLE). 4.CEMENT CONCRETE STEPS AND CURBS SHALL BE CONSTRUCTED AS SHOWN. 5.HEIGHT OF RAILING SHALL BE 36" MINIMUM, 38" MAXIMUM TOP OF NOSING TO TOP OF RAILING. 6.PEDESTRIAN RAILING SHALL BE CONSTRUCTED AS SHOWN. 7.STAIR FORM SHALL BE LAYED OUT AND APPROVED BY ENGINEER BEFORE PROCEEDING PLACING CONCRETE 12" 16" COMPACTED SUBGRADE SEE POST DETAIL 1/4 TYP. @ EACH POST FOR ALL RAIL SECTIONS HANDRAIL DETAIL SEE HANDRAIL DETAIL CORE DRILL AND EMBED POSTS MIN. 12" DEEP IN CONCRETE FOOTING. ANCHOR WITH RAPID SET MULTI-PURPOSE CEMENT ALL OR EQUAL. 12" 2'-10" 1'-3" 2'-10" BOTTOM OF STAIRS HANDRAIL NOTES: A.GRIND WELD JOINT SMOOTH B.HOT DIP GALV. AFTER FABRICATION C.PIPE TO FOLLOW ALIGNMENT SHOWN ON PLANS. D.PROVIDE SHOP DRAWINGS. E.VERIFY POST LOCATIONS BEFORE CORING. 17"-19" 6.00" R0.25" TYP. R1.00" TYP. FG TOP OF STAIRS MIN. FOOTING 9" x18"D IF IN PAVEMENT; COORDINATE TOP OF FOOTING 6.00" 1½" DIA. STEEL PIPE CONCRETE STEPS (SEE STEP DETAIL FOR DIMENSIONS) HANDRAIL AT CONCRETE STEPS ME A S U R E D F R O M N O S I N G ℄ T R E A D ℄ T R E A D 3/4" SCH 40 (STD PIPE) BALUSTERS INSERTED IN HOLE AND TACK WELDED OPPOSITE TRAFFIC #4 BARS 2' CC #4 BARS 2' CC 4 #4 BARS 4" CURB RADIUS SEE NOTE 4 BELOW FOR RISER AND TREAD DIMENSIONS 4" CURB RADIUS 8" WIDE CURB BOTH SIDES OF STEPS 1/4" SLOPE R0.5" 12" 1.5" STD. PIPE 16 GA. GALV. STEEL SLEEVE 3" DIA. STEPS DETAIL SLOPE TO DRAINNON-SHRINK GROUT FINISH SURFACE +2.00' EJ #4 BARS 2'-0" O.C.FINISH SURFACE ±0.00 A A CONCRETE STAIRS SECTION CONCRETE PAVING (TYP.) CONCRETE STEPSCONCRETE CURB GALVANIZED STEEL HANDRAIL (SEE HANDRAIL DETAIL FOR DIMENSIONS) EMBED POSTS IN CONCRETE FOOTING. ANCHOR WITH RAPID SET MULTI-PURPOSE CEMENT ALL OR EQUAL. CONCRETE PAVING (TYP.) R1" R0.5" CONSTRUCT INDICATOR STRIPES 1/4" DEEP BY 1/8" WIDE. SPACE STRIPES 3/4" O.C. WITHIN A 2" WIDE STRIPE ALONG THE NOSE OF EACH TREAD. APPLY L.M. SCOFIELD CHEMSTAIN TO INDICATOR STRIP. COLOR TO BE CS-2 PADRE BROWN. ℄ T R E A D 12" 1-1/2" INCH DIA. GALVANIZED STEEL SCH 40 HANDRAIL EJ STAIR 'A' 6.00' 0 5" 5.00" 5.00' 16" 4" 8" 2" 6.00' MAX 12.00" 12.00" 2" 3.5" 0.5" 18.15" 12.00" 36"-38" UNIFORM RISER TREAD 1"2" 18" 412.50 412.92 413.35 413.77 414.20 414.62 415.05 415.47 +0.42 +0.85 +1.27 +1.70 +2.12 +2.55 +2.97 STAIR 'B' 6.00' 0 415.72 416.14 416.57 416.99 417.41 417.83 418.26 418.68 +0.42 +0.85 +1.27 +1.69 +2.11 +2.54 +2.96 STAIR 'C' 6.00' 0 418.77 419.19 419.62 420.04 420.46 420.88 421.31 421.73 +0.42 STAIR 'D' 6.00' 0 421.82 422.24 422.67 423.09 423.52 423.94 424.37 424.79 +0.42 +0.85 +1.27 +1.70 +2.12 +2.55 +2.97 STAIR 'E' 6.00' 0 425.05 425.47 425.90 426.32 426.75 427.17 427.60 428.02 +0.42 +0.85 +1.27 +1.70 +2.12 +2.55 +2.97 +0.85 +1.27 +1.69 +2.11 +2.54 +2.96 CONCRETE PAVING 1/2" MAX. EXPANSION JOINT LANDSCAPED AREA 1-1/2"Ø GALV. STEEL PIPE (I.D.) RAILING & POST. POST 4'-0" O.C. MAX. 1-1/2"Ø GALV. STEEL PIPE HAND RAIL 1/2" TOOLED RADIUS 2" IDØ STD. GALVANIZED PIPE SLEEVE WITH CAP WELDED AT BOTTOM. FILL SLEEVE WITH NON-SHRINK GROUT RAIL FOUNDATION DETAIL #3 REBAR 180 DEG BEND 24" LONG AT EACH PIPE SLEEVE (2) #4 CONT. 36" 6" 30" 1'-2" 12" 1.50" 12" 18" F210 3 CONCRETE PAVING LANDSCAPED AREA 1-1/2"Ø GALV. STEEL PIPE (I.D.) RAILING & POST. POST 4'-0" O.C. MAX. 1-1/2"Ø GALV. STEEL PIPE HAND RAIL #3 REBAR 180 DEG BEND 24" LONG AT EACH PIPE SLEEVE 36" 6" 12" 1.50" 12" 18" F210 3 12" CITY OF RENTON IN COMPLIANCE WITH CITY OF RENTON STANDARDS TE D - 4 0 - 4 3 4 4 D.A. Hogan & Associates, inc. 1450 114th Ave. SE, Suite 225 Bellevue, WA 98004 206-285-0400 R-4344 PR : LU A : C: LU A 2 5 - 0 0 0 0 5 1 PR 2 5 - 0 0 0 0 1 8 C2 5 0 0 0 9 7 7 LINDBERGH HIGH SCHOOL SITE STAIR DETAILS FIELD IMPROVEMENTS 40 NOT TO SCALE CONCRETE STAIRS F270 1 NOT TO SCALE HANDRAIL FOUNDATION AT STAIRS F270 2 NOT TO SCALE HANDRAIL FOUNDATION DETAIL AT RAMP F270 3 CIVIL CONSTRUCTION PERMIT 2/21/25 CIVIL CONSTRUCTION PERMIT RESUBMITTAL 4/14/25 CIVIL CONSTRUCTION PERMIT RESUBMITTAL 6/4/25 DEVELOPMENT ENGINEERING HBray 06/24/2025 R 1 3 . 0 0 ' 90 . 0 0 ' (T Y P . ) R95. 0 0 ' R 1 3 . 0 0 ' 24.50' 90.00' (TYP.) R9.00' 60.50' 6.00' (TYP.) 3.00' 45 . 0 0 ' 45 . 0 0 ' 15 . 0 0 ' 5.00' 20 . 0 0 ' 3.00' 3" INLAID LINE (TYP.) BASEBALL BATTER'S BOX INLAID WHITE COACHES BOX (TYP.) BASE WITH ANCHOR (TYP.) GREEN SYNTHETIC TURF W/ ALTERNATING PANELS (TYP.) BASE AND PLATE ANCHOR LAYOUT BROWN SYNTHETIC TURF (TYP.) LIMIT OF INFIELD (TYP.) 3" INLAID FOUL LINE (TYP.) 3" INLAID FOUL LINE (TYP.) PITCHER'S MOUND 12.00' WARNING TRACK (TYP.) BULLPEN MOUND BULLPEN AREA BULLPEN MOUND BULLPEN AREA 12.00' WARNING TRACK (TYP.) GREEN SYNTHETIC TURF WITH ALTERNATING PANELS (TYP.) SYNTHETIC TURF EDGE ANCHOR (TYP.) SYNTHETIC TURF EDGE ANCHOR (TYP.) SYNTHETIC TURF EDGE ANCHOR (TYP.) F220 1HOME PLATE F310 2 F220 2 F220 5 F221 1 F250 3 F250 1 F250 3 F250 1 F221 1 F221 1 R 1 6 6 . 5 0 ' F222 1 GREEN SYNTHETIC TURF WITH ALTERNATING PANELS (TYP.) 15.00' (TYP.) 15.00' (TYP.) 15.00' (TYP.) 7.50' (TYP.) 7.50' (TYP.) 6. 0 0 ' 3. 0 0 ' 4.00' 3rd BASE LINE 1s t B A S E L I N E R13.00' 6" 43" 8. 0 0 ' NOTES FOR REMOVABLE INSERTS: 1.ADHERE 12" SEAM TAPE WITH 2" MIN. EXPOSURE TO UNDERSIDE OF PERMANENT TURF. 2.ADHERE 2" VELCRO "HOOK" TO EXPOSED SEAM TAPE. 3.ADHERE 2" VELCRO "LOOP" TO SEAM TAPE 4.ADHERE 12" SEAM TAPE WITH CENTERLINE ALIGNED WITH TOP EDGE OF CATCHER'S BOX OPENING. 5.ADHERE (2) 2" VELCRO "HOOK" PIECES TO EXPOSED SEAM TAPE WHERE MULTIPLE REMOVABLE INSERTS MEET. 6.FURNISH 4 ADDITIONAL REMOVABLE REPLACEMENT TURF PATCHES EACH LOCATION (5 TOTAL). 6" (TYP.) 29" 6" (TYP.) 2" TYPICAL VELCRO SEAM 1 PERMANENT TURF REMOVABLE INSERT BROWN COLORED INFILLED SYNTHETIC TURF 3" WHITE LINE 3" WHITE INLAID LINE REMOVABLE TURF INSERT WITH VELCROREMOVABLE TURF INSERT WITH VELCRO HOME PLATE 1 2 3 F220 1 CITY OF RENTON IN COMPLIANCE WITH CITY OF RENTON STANDARDS TE D - 4 0 - 4 3 4 4 D.A. Hogan & Associates, inc. 1450 114th Ave. SE, Suite 225 Bellevue, WA 98004 206-285-0400 R-4344 PR : LU A : C: LU A 2 5 - 0 0 0 0 5 1 PR 2 5 - 0 0 0 0 1 8 C2 5 0 0 0 9 7 7 CIVIL CONSTRUCTION PERMIT 2/21/25 CIVIL CONSTRUCTION PERMIT RESUBMITTAL 4/14/25 CIVIL CONSTRUCTION PERMIT RESUBMITTAL 6/4/25 LINDBERGH HIGH SCHOOL BASEBALL LAYOUT PLAN & DETAILS FIELD IMPROVEMENTS 41 SCALE: 1"=20' BASEBALL LAYOUT PLAN F310 1 NOT TO SCALE BASEBALL BATTERS BOX F310 2 DEVELOPMENT ENGINEERING HBray 06/24/2025 205' 20 5 ' 15.00' 3.00' R8.00' 30.00' 8.00' 3.00' R60.00' 12.00' WARNING TRACK (TYP.) 60.00' TYP. 43.00' 24.49' LIMIT OF INFIELD (TYP.) COACHES BOX HOME PLATE SOFTBALL BATTER'S BOX COACHES BOX BASE WITH ANCHOR (TYP.) 3" FOUL LINE 3" FOUL LINE PITCHER'S PLATE GREEN SYNTHETIC TURF OUTFIELD (TYP.) GREEN SYNTHETIC TURF OUTFIELD (TYP.)BROWN SYNTHETIC TURF INFIELD (TYP.) SOFTBALL BULLPEN AREA SOFTBALL BULLPEN AREA F220 1 F320 2 F220 4 F320 3 F250 2 F250 2 12.00' WARNING TRACK (TYP.) 12.00' WARNING TRACK (TYP.) 7. 0 0 ' 3. 0 0 ' 3.00' 3r d B A S E L I N E 1st B A S E L I N E 4. 0 0 ' 2'-5" 8'-5" 10 . 0 0 ' NOTES FOR REMOVABLE INSERTS: 1.ADHERE 12" SEAM TAPE WITH 2" MIN. EXPOSURE TO UNDERSIDE OF PERMANENT TURF. 2.ADHERE 2" VELCRO "HOOK" TO EXPOSED SEAM TAPE. 3.ADHERE 2" VELCRO "LOOP" TO SEAM TAPE 4.ADHERE 12" SEAM TAPE WITH CENTERLINE ALIGNED WITH TOP EDGE OF CATCHER'S BOX OPENING. 5.ADHERE (2) 2" VELCRO "HOOK" PIECES TO EXPOSED SEAM TAPE WHERE MULTIPLE REMOVABLE INSERTS MEET. 6.FURNISH 4 ADDITIONAL REMOVABLE REPLACEMENT TURF PATCHES EACH LOCATION (5 TOTAL). 2" TYPICAL VELCRO SEAM REMOVABLE TURF INSERT WITH VELCRO EDGE 3" WHITE INLAID LINE HOME PLATE REMOVABLE INSERT PERMANENT TURF 11 32 F220 1 PITCHER'S CIRCLE 60' INFIELD ARC RADIUS R8' PITCHER'S CIRCLE ℄ ℄ NOTES FOR REMOVABLE INSERTS: 1.ADHERE 12" SEAM TAPE WITH 2" MIN. EXPOSURE TO UNDERSIDE OF PERMANENT TURF. 2.ADHERE 2" VELCRO "HOOK" TO EXPOSED SEAM TAPE. 3.ADHERE 2" VELCRO "LOOP" TO SEAM TAPE 4.ADHERE 12" SEAM TAPE WITH CENTERLINE ALIGNED WITH TOP EDGE OF CATCHER'S BOX OPENING. 5.ADHERE (2) 2" VELCRO "HOOK" PIECES TO EXPOSED SEAM TAPE WHERE MULTIPLE REMOVABLE INSERTS MEET. 2" TYPICAL VELCRO SEAM 1 3.5' 46' F R O M HO M E P L A T E 43' F R O M HO M E P L A T E 10' REMOVABLE TURF INSERT WITH VELCRO EDGE PITCHER'S PLATE PERMANENT TURF REMOVABLE INSERT 1 32 F220 4 CITY OF RENTON IN COMPLIANCE WITH CITY OF RENTON STANDARDS TE D - 4 0 - 4 3 4 4 D.A. Hogan & Associates, inc. 1450 114th Ave. SE, Suite 225 Bellevue, WA 98004 206-285-0400 R-4344 PR : LU A : C: LU A 2 5 - 0 0 0 0 5 1 PR 2 5 - 0 0 0 0 1 8 C2 5 0 0 0 9 7 7 CIVIL CONSTRUCTION PERMIT 2/21/25 CIVIL CONSTRUCTION PERMIT RESUBMITTAL 4/14/25 CIVIL CONSTRUCTION PERMIT RESUBMITTAL 6/4/25 LINDBERGH HIGH SCHOOL SOFTBALL LAYOUT PLAN & DETAILS FIELD IMPROVEMENTS 42 SCALE: 1"=20' SOFTBALL LAYOUT PLAN F320 1 NOT TO SCALE SOFTBALL BATTERS BOX F320 2 NOT TO SCALE SOFTBALL INFIELD ARC LAYOUT F320 3 DEVELOPMENT ENGINEERING HBray 06/24/2025