HomeMy WebLinkAboutR-434305EX CB
RI#= 3296
lE 12" PVC (NE)A9.,3
FND MON IN CASE
INT OF PARK AVE N
N. & N. 6TH ST
NO. 947
fl
CD
o I
/ d-
�,
ICD �
z
ECB
33.28
l>2c" l
'94
lE>2VC S ?3
I
/24'CE, ?4.7
AS
GAS -
°'
DO NOT DEMO EX
RIM= 32. DRIVEWAY CURB CUT
IF 8" CON UNTIL WORK IN THE
RIGHT-OF-WAY BEGINS
L PUMP "CLEAN" STORMWATER FROM
TEMP SEDIMENT SETTLEMENT TANKS TO
EXISTING CATCH BASIN. CONTRACTOR TO
ENSURE ALL DISCHARGE MEETS
TURBIDITY REQUIREMENTS.
24 "" SO
SILT FENCE
IP SEE DETAIL
,vy 6
AS -� C210 GAS
0
I i
DO NOT DEMO EX D°
'DRIVEWAY CURB CUT
I UNTIL WORK IN THE I SW
IGHT-OF-WAY BEGINS I
II IP l❑
� D
I EX cB I e
i 42
47.-1
1E 12 P I E =29.2 I I° -
I I I I1
� � I
I I �
P I P
T�
1 _
I I I
1 W °I
DO NOT DEMO EX
P a
DRIVEWAY CURB CUT I
UNTIL WORK IN THE
°I
°
RIGHT-OF-WAY BEGINS '
I D I
1 I
UTILIZE EX CURB CUT OPENING ; N
AFTER DEMO OF CONCRETE
DRIVEWAY FOR INSTALLATION I
OF TEMPORARY ROCK I
CONSTRUCTION ENTRANCE
I I I ° ° I
I
L PUMP CONSTRUCTION
STORMWATER TO SEDIMENT
SETTLEMENT TANKS
(CA ZONING)
PARCEL#7224000676
SUMP AND 55 GALLON
DRUM WITH SUMP PUMP
INSTALLED AT LOW
POINT ON SITE SEE DETAIL
c5
S89°02'47"E 106.47'
IS
18,900 GALLON CAPACITY TEMPORARY
SEDIMENT SETTLEMENT TANK ("BAKER
TANK" OR EQUAL). CONTRACTOR SHALL
PROVIDE ALL PUMPS REQUIRED TO
MANAGE CONSTRUCTION STORMWATER
AND DISCHARGE AT THE SITE.
\ APPROXIMATE
\ PROPERTY LINE
`INTERCEPTOR TO BE SURVEYED
SWALE (TYP)
SEE DETAIL
c1
/ (CA ZONING)
PARCEL#7224000675
100,
EX SSMH
RIM= ,3,3.45
8" PASSING N TO S DIP
TOP OF PIPE =27.0
1E 24'C#P(E)-24. 9
IF 24'C#P(91)=24.9
PROTECT EX TREE TO
REMAIN INSTALL TREE
PROTECTION FENCING
- w SEE DETAIL (TYP)
c1
a.. GAS
20 DEC
SE 1 4 SECTION 08 T. 23 N, R. 5 E. W. M . FND MON IN CASE
/ / / / INT OF GARDEN AVE
EX CB
N. & N. 6TH ST
EX SSMH RIM= 33.53 NO. 1676
Rl# =33.49 /E 12 CONC(N)=25.9 EX CB
If 8 ST (5)=26.2 /E 24'C#P(L-)=25.0 Rl# J2.86
lE 8' PVC (N)=25.4 /E 24'C#P(W)=25.0 /E 12 CONC(N)=259
lE 18'CMP(5)=25.57 /E 12 CONC(S)-25.7
lE 8" C#P(N11)=27.7
- - --- - �, Z I
FND REBAR AND CAP L.S. 8„SD
11926 I2 &AIDY
' EX -
W o 0.1SOUTH & 0.5' WEST PROP COR _ _ W D W w w
°v w SD
w
EXISTING PARKING LOT _ 33- - - - AVOrth _5th Street 12"WATER =29.17LCIV CB
DRIVEWAY CURB CUT (GATED) - - CB Rl#= 3 4 W - w 4 CB TYPE 2-48" W �'065E 4#fr - - - w - - - _ w If- 8'PVC(SE 29.57
IM= 34 n1 - -
CTYPF-54" 24" SD IE= 28.96 18"(IN) E RIM= 3287
CDS PRETRE ENT S =-T#D .42 S� _ Spy SD Sp L
IE= 25.70 18"(IN) S RIM= 34.19 _ W RISER TOP_3L46 - - - - - lE 8'COyL(F�-260- - _33 -
IE= 25.78 18"(IN) E IE=28y$9 (INS-S� - - - - W RISER BTM= 27.06 /E 8'CONC(5�=29.22 Q`�Q
-33- c� FND MON IN CASE
- - - - - -r �5.7T-1rOj 17- - 3 IE- 28.76 6"(OUT) E D IE= 29.05 18"(OUT) W P 3/8" COPPER PLUG
�' IN CONC (DN-0.7)
------- � SW RISER TOP= 31.21
- G GAS GAS GAS GAS ° FND REBAR AND CAP_ T.S.A. 12 57W GAS GAS GAS - - GAS RIY= 3214
° 34/10356PVC(N)=287
EX .
• p°
20.00' G - - - ° D °-A3.VACVF�S S Rl#- 2
O o -------34- - - - - - - S89°00'57E 259.57 N -
---------34-----
SAND/OILPARATOR / \ \ /
RIM- 34.47 \ / SD #4b CB TYPE 1
O NE RISER TOP- X56 \ I
O VE J SD #4a CB T P�2-48" \ RIM= 33.53 /
I P -NE RISER IE= 29.69 \ RIM= 33,.51 \ iE= 30.78 8"(OUT) W yn
;B TY E 2-48" / ° I NE RISER BTM= 25.69 IE- 25.96 8"(IN) E \
3.49 °° VE I SW RISER TOP= 30.57 29.21 18"(IN) S
IE- z\ /
0.52 8"(IN) E SW RISER IE= 29.62 \ /
IP I SW RISER BTM= 25.71 y� IE= 29.21 18"(OUT) W \ / I co
2.12"(IN) S \ BTM STRCT- 24.45
IE= 25.74 18"(OUT) N � ° I ( I
SD #9a CB TYPE 1
RIM- 32.96 ll STORM FILTER VAULT I I D
O 0= 29.62 8"(1)UT) SE 0 I 8'x22' CONCRETE VAULT I I
/ O Ile W/ 41 CARTRIDGES °
RIM= 34.07 & 34.09
U) 0 IE= 28.82 8"(IN) E I AS VAULT
IE= 28.64 8"(our) W O I I I P
TALLSD
SD #9 CB TYPE 2-60 °° 0 I R M#3
34.20YPE 2-54°
ECO PAN FOR CONCRETE - 33.37 q IE= 29.09 8"(IN) W
a TRUCK CLEANOUT; FINAL E= 29. 8"(IN) NW IE= 29.04 8"(IN) NE o
O O I°I
LOCATION TO BE IE= 29.28 8 T) E I IE= 29.10 8"(OUT) NW I
COORDINATED IN FIEL[5 RISER TOP= 31.25
DURING CONSTRUCTION. E R BTM= 25.05
E= 28.60 18 UT) N ° -��- -35
ISER TOP= 31.25 PROTECT EX TREE e I
0 N RI BTM= 25.05°f VEG TO REMAIN O
BTM STR 25.05 SEE DETAIL (TYP) ° I I II
IE= 29..
IE- CID 1# chi) IE= 29.OUl/
0 I� EXISTING BUS
INSTALL CB J ' \�) 0 q I a PARKING LOT
PROTECTION I SD #10a PP�1 9f D o I I
SEE DETAIL (TYP)RM= I293.480008 "\ O I I I
l
RIDGE I d I
EXISTING STAFF
STABILIZED I \ I
AND FLEET VEHICLE I I
CONSTRUCTION ACCESS IS I o OO PARKING LOT EX CONCRETE VACUUM \ I I I I
SEE DETAIL g 0 I STATION PLINTH
c21 Iq I I I I I
° I
(IL ZONING) I I
c/' 0 PARCEL #7564600105 O 1 � IE= 33.62 \\ I I I
Qua a0000l SW x �, \ �' I "' II
)gpq9� L J
0 0 0
Co I °°� / I SD #5 CB E 2-48" IE- 34.57 I J 12SIDDp I
o��G` I STRAW / I RIM= .75 I E1 CB
VEG 1 0 I IE= 31J5 6"(IN) ° I I R1�2CPEP =3032 I
VEG WATTLE (TYP) /°�q :I IE 30.18"(IN) S 01 O O
SEE DETAIL / IE= i8"(OUT) N
9 � I I
� �
I I I 1
471E 106.20 - - C210 lk I o
(IL ZONING) \ I I I C/�
PARCEL#7564600105 °
I \ \ I I De
IP V PROT�T EX T � . 2 I �� \\
IE= 31.64 12"(OUT) SE
EX c67w I I VEG \ o
cn
1E 12PV "N =28.5 I \ EX CONCRETE VACUUM
lE >2 Ps =2
V 8.5 (IL ZONING) I �°
lE 12PV - =28 ` o PARCEL #7564600105CID\ I STATION PLINTH - - - O
- - - - - - - - - - -36- - - - - - - - - - - - - - I °
I
z VEG EXISTING VISITOR
\ PARKING LOT I o I SD CB TYPE 2-48"
I RIM- 35.83 °
PROTECT I 0 IE= 30.56 12"(IN) SW VEG O
\ - 30.56 12"(OUT) NW I
EX PIV \ I
' M
D
EX C6
R//W
IF 18'
lE 19'
lE 12'
Call before you
Dag.8-1-1 '5-
or 1-800-424-S5SS
UNDERGROUND T
SERVICE (USA) T
0 10 20 40 8 O
0 N
SCALE 1 "=20' U
LEGEND
PROPERTY LINE
N 79'33'06" E - 46.81'
IS INTERCEPTOR SWALE
FF FILTER FABRIC FENCING
INLET PROTECTION
IP
VEG TREE PROTECTION
SEDIMENTATION TANK
o 13
SEDIMENT TRAP
O
CE TEMP CONSTRUCTION
v v
ENTRANCE
U UJ
MATCHLINE - SEE BELOW LEFT
°
Sohn
I SD CO
I
. I
I
_ i I
I
° I
I
a
DS
IE= 3 EXISTING IE= 28.09
BUILDING
13
SEDIMENT TANK STORAGE
VOLUME REQUIRED: 10,527 GALLONS
VOLUME PROVIDED: 18,900 GALLONS
CONSTRUCTION RECORD DRAWING
THIS CONSTRUCTION RECORD DRAWING IS A COPY OF A CAD FILE
PREPARED BY JACOBSON CONSULTING ENGINEERS, AND HAS BEEN
EDITED TO REFLECT THE AS -BUILT CONDITIONS OF THE PROJECT.
FIELD DIMENSIONS AND INFORMATION THAT WAS PROVIDED BY
BAYSHORE CONSTRUCTION COMPANY, AND PROVIDED TO
JACOBSON CONSULTING ENGINEERS IN OCTOBER 2025.
JACOBSON CONSULTING ENGINEERS DOES NOT PROVIDE ANY
WARRANTY AS TO THE ACCURACY OR COMPLETENESS OF SUCH
INFORMATION PROVIDED BY OTHERS.
SEE SHEET C001 FOR TESC
CONSTRUCTION SEQUENCE NOTES
SEE SHEET C001 FOR CITY OF
RENTON ESC STANDARD PLAN NOTES
NOTE:
INSTALL CONSTRUCTION FENCING AROUND LIMITS OF
WORK TO PROTECT STAFF AND STUDENTS AND SECURE
JOBSITE. CONTRACTOR SHALL ERECT FENCE AROUND
JOBSITE AND ADJUST AS CONSTRUCTION CONDITIONS
CHANGE OR AS PHASING ALLOWS. CONTRACTOR CAN UTILIZE
EXISTING PERIMETER FENCING AS SECURITY FENCING AND
THEN SUPPLEMENT ON THE WEST SIDE OF THE SITE AS
NEEDED. ANY SECTIONS OF EXISTING FENCING THAT IS NOT
6-FT HIGH SHALL HAVE TEMPORARY 6-FT HIGH CHAINLINK
FENCING INSTALLED NEXT TO IT. SEE DETAIL 9/C210.
'
O PIV
\ I
o VEG PROTECT \ °% O I I
/ XF C o FH IP 9°f I SAND/OIL S RATOR ° I I d IN COMPLIANCE WITH CITY OF RENTON STANDARDS
I 1 `r � E � � 0 I RIM- 36.82 & .87 W I .
RISERI ' m
EXISTING SECURITY GATE °° 6" 70P= 2 . 7 W I I
-j�-- -- ` / SER6"IE=28.47
T I - (NO PUBLIC ACCESS - - '°f LV °Ri ER 6" BTM= 24.45E
N I P J 36� BEYOND THIS POINT)
a 2" RP I R 6" TOP= 29.34 E O r I
CDI I SD #12 CB RIM= 34.95 PRE GT E 2° WA T ME 7 I E 6" IE= 28.47 E o I I I
w W IE=-
4 6WI DDCVA VAULT I RIS R "CT- 24.4545
IE= 31.02 12"(IN) NW IE= 30.97 12"(OUT) NE ° �c SS CO
_\ - I RID(
® o ® A• Jq C _ OOF DOWNSPOUT I ..
vas
° ° �1� RECORD DRAWINGS SE 11/3/25 SURVEYED: SCALE:
C] HORIZONNTALL: NAD 1983/1991 • RSD TRANSPORTATION EXPANSION
c s W DESIGNED:SSE/REG o CITY OF
RENTON
DRAWN:
DJD/AJJ ONE INCH •
MATCHLINE - SEE ABOVE RIGHT �'�c s6TER�9 CHECKEDJAJ AT FULL SCALE DATUM Planning/Building/Public Works Dept. T. E.S.C. PLAN
IF NOT ONE INCH
S��NAL E� N 0 . REVISION BY DATE AP P R APPROVED: SCALE ACCORDINGLY
DATE:
11/03/25
FIELDBOOK:
PAGE:
DRAWING NO:
C201
SHEET: OF,
5 OF 3C
O
1
N
0
O
1
N
Q
J
R-434305