Loading...
HomeMy WebLinkAboutR-434316co 11:t 10 I ATTACH SIGN SITE SIGNS SHALL CONFORM TO THE MANUAL ON UNIFORM O NOTES: TRAFFIC CONTROL DEVICES WITH 2 DRIVE ° 0 RESERVED 1. METAL POSTS SHALL BE TELESPAR QUICK PUNCH POST RIVETS. SEE NOTE STOP SIGN R1-1 (30") PARKING Lij LEFT TURN MUST YIELD R10-1201 ° ° EACH PARKING SPACE RESERVED FOR PERSONS WITH _ SIGNS MUST CONFORM - 2. METAL STOP AND YIELD SIGN POSTS SHALL HAVE ALTERNATING T ° DO NOT ENTER R51 (30") RESERVED RESERVED PHYSICAL DISABILITIES SHALL BE IDENTIFIED BY A MUTCD ° TO MUTCD STANDARDS BANDS OF RED AND WHITE 3M DIAMOND GRADE SHEETING. ALL ° NO RIGHT TURN R3-1 (30") PARKING PARKING REFLECTORIZED SIGN PERMANENTLY POSTED IMMEDIATELY r I R7-8 OTHER POSTS SHALL BE UNSHEETED o SIGN POST NO LEFT TURN R3-2 (30") ADJACENT TO AND VISIBLE FROM EACH STALL OR SPACE CORNER BOLT ° SQUARE 2"x2", 14 RIGHT TURN ONLY R3-5R R7-8 CONSISTING OF A PROFILE VIEW OF A WHEELCHAIR WITH STATE DISABLED PARKING OCCUPANT IN WHITE ON DARK BLUE BACKGROUND. THE PERMITREQUIRED 3. FOR IN -SIDEWALK INSTALLATIONS, CORE 4" DIAM. HOLE. ANCHOR SEE NOTE 7 o GUAGE. QUICK PUNCH LEFT TURN ONLY R3-5L ° METAL SIGN; BOLT LENGTH MAY BE DECREASED TO 12" NO PARKING FIRE LANE* 7-107 MODIFIED PER SIGN SHALL NOT BE SMALLER THAN 70 SQUARE INCHES IN 2" o STATE DISABLED PARKING STATE DISABLED PARKING ° TO PIPE COLUMN GROUND SURFACE BELLEVUE FIRE REQ TO READ: PERMIT REQUIRED PERMIT REQUIRED AREA AND SHALL BE CENTERED ON AND JUST BEYOND THE MUTCD VAN 4. POST SHALL BE ROLLED CARBON SHEET STEEL, ASTM A570 GRADE "NO PARKING FIRE LANE" ° ° FRONT EDGE OF THE PARKING STALL. SIGNS MAY ALSO BE R7-8A ACCESSIBLE MUST CONTAIN WORDING: 50 AND BE HOT DIPPED GALVANIZED AASHTO M-120 YIELD �� o ' ACCESSIBLE LOADING* R7-801A (18"x9"): MODIFIED ° HUNG ON THE WALL AT THE INTERIOR END OF THE PARKING SIGN POST "STATE DISABLED PARKING STRENGTH 60,000 PSI MIN. POST SHALL HAVE 7 16" = AN SQUARE R7 8A VAN SPACE. SIGN MOUNTING HEIGHT SHALL BE 60 INCHES / c� TO READ ACCESSIBLE ACCESSIBLE SEE DETAIL PERMIT REQUIRED" DIE -PUNCHED KNOCKOUTS ON 1" CENTERS FULL LENGTH, FOUR N 2.5"x2.5" O.D. 7 LOADING" ABOVE THE PARKING SPACE FINISHED GRADE. _ SIDES. GUAGE, 24" LENGTH AUTHORIZED VEHICLES ONLY* R4-3 (30"x36"): MODIFIED TO o 2 SEE NOTE 5 DISABLED AN ADDITIONAL SIGN SHALL ALSO BE POSTED, IN A in c51 READ AUTHORIZED VEHICLES GRADE 5. ANCHOR SHALL HAVE 4 7/16" HOLES ONE EACH SIDE 2" FROM TOP 2" 2 CUBIC FT. CONCRETE ONLY" ACCESSIBILITY CONSPICUOUS PLACE, AT EACH ENTRANCE TO OFF-STREET END. FINISH SHALL BE ZINC HOT DIPPED GALVANIZED MATERIAL VISITOR PARKING* R4-3 (30"x36"): MODIFIED TO SIGNAGE PARKING FACILITIES, OR IMMEDIATELY ADJACENT TO AND TO MEET ASTM A500 GRADE B. READ "VISITOR PARKING" VISIBLE FROM EACH STALL OR SPACE. THE SIGN SHALL BE SQUARE METAL POST CURB LANE LOADING ONLY* R4-3 (30"x36"): MODIFIED TO NOT LESS THAN 17 INCHES BY 22 INCHES IN SIZE WITH 6. DRIVE RIVETS TO BE TL3806 3/8" DIA. READ "CURB LANE LOADING LETTERING NOT LESS THAN 1 INCH IN HEIGHT, WHICH ONLY" CLEARLY AND CONSPICUOUSLY STATES THE FOLLOWING: 7. CORNER BOLTS TO BE TLCB516M. *CONTRACTOR SHALL SUBMIT A MOCK UP OF ALL MODIFIED SIGNS TO ENGINEER FOR APPROVAL UNAUTHORIZED VEHICLES PARKED IN DESIGNATED U PRIOR TO ORDER OR PURCHASE OF SIGNS DISABLED PARKING SPACES NOT DISPLAYING DISTINGUISHING PLACARDS OR LICENSE PLATES ISSUED FOR PHYSICALLY DISABLED PERSONS MAY BE TOWED AWAY AT OWNER'S EXPENSE. TOWED VEHICLES MAY BE RECLAIMED AT OR OR BY TELEPHONING " NTS NTS A Site Signage PAINTED BLUE BACKGROUND Accessible Parking Sign '�F NPAINTED WHITE LOGO INTERNATIONAL ACCESS SYMBOL PAINTED ON PAVING DISABLED ACCESSIBILITY SIGNAGE ON POST (LOCATION PER PLAN) STRIPE LINE PER PLAN SEE DETAILS ABOVE AND DETAIL 4 C51 4' MIN � WHEEL STOP 0 z SEE DETAIL 0 J A DETECTABLE WARNING PATTERN AREA p p 0 w SHALL BE YELLOW, IN COMPLIANCE WITH INTERNATIONAL ACCESS SYMBOL B WSDOT STANDARD SPEC. 8-14.3(3) PAINTED ON PAVING 0 _ SEE DETAIL ABOVEno 0 3/16"-� �C CROSSWALK STRIPING SEE DETAIL p8 � PER PLAN 12" 12" (TYP) (TYP) D � NOTES: 1. STRIPING COLOR SHALL BE "WHITE" AND PAINTED PER PROJECT SPECIFICATIONS 2. STRIPING DIMENSIONS SHALL MEET MUTC SPECIFICATION 313-18 AND FIGURE 3-14C. NTS NTS NTS NTS n Not Used--(: Truncated Domes ADA Symbol and Blockout Striping Crosswalk Striping a IN COMPLIANCE WITH CITY OF RENTON STANDARDS EDEVELOPMENT ENGINEERING HBray 06/13/2025 NTS 1 o NTS 11 A. j Not Used Not Used °` "Asy� BID SET SE 4/10/25 SURVEYED: SALE: RSD TRANSPORTATION EXPANSION DATE: o5 21 25 VERTICAL: �� 1981 CITY OF PERMIT COMMENTS SE /14/2 HORIZONTAL: NAD 1983/1991 w , DESIGNED: FIELDBOOK: ADDENDUM 1 AJ /17/2 SSE/REc RENTON PAGE: 1 3 ADDENDUM 2 AJ 5/1/25 °RPWNt DJD/AJJ ONE INCH DATUM � DRAWING N0: NTS43667 AT FULL SCALE Planning/Building/Public Works 9 R C� PERMIT COMMENTS SE /21 2 CHECKED: Dept. Not Used �sSIUNAL v��� 4 / APPROVED:AJ SIF NOT CALE ONE I NGLY PAVING DETAILS SHEET. C 511 NO. REVISION BY DATE APPR 1OR i6 OF 3 R-434316 MIN MAX A 15/8" 2 3/8" B 5/8" 11/2" C 7/ 16" 3/4" D 7/8" 17/16" O T C] Ln N A u 0) O O I N Ir 'i1 co O I 4 Q J